Wireless Smart Gluco-‐Monitoring System (BG5)
QUICK START GUIDE WELCOME Welcome to your iHealth Wireless Smart Gluco-‐Monitoring System (the iHealth system). Designed to be used with the free iHealth Gluco-‐Smart App (the app), the system will help you manage your diabetes in an easy and convenient way. Contents of the Wireless Smart Gluco-‐Monitoring System These contents may vary by region. Please refer to the package contents listed on the package you purchased.
. iHealth Smart Glucose Meter (the meter)
. Clear Cap for Alternate
. iHealth Lancing Device
. Lancet
. Travel Case
. USB Charging Cable
. Owner's Manual
. Quick Start Guide iHealth control solution and iHealth test strips sold separately.
. iHealth Test Strip
. iHealth Control Solution
FIRST TIME SETUP INSTRUCTIONS
. Download the companion app Prior to first use, download and install the free iHealth Gluco-‐Smart App from the Apple App Store or Google Play Store. Follow the on-‐screen instructions to create your iHealth account. . Access iHealth Cloud
You can use your iHealth ID to gain access to free and secure Cloud Services. Go to www.ihealthlabs.com and click on "Sign In". . Charge the battery Out of the box Your meter is powered by a built-‐in, rechargeable battery. Plug one end of the charging cable into the side of the meter and the other end into your computer's USB port. Charge it for two to four hours before first use. A fully charged battery can typically take up to 200 tests depending on your daily usage. Low battery message
After you have used your meter for some time, appears for three seconds when the
battery in your meter is low on power. You must recharge the battery before using it again. After three seconds, the meter shuts off automatically. The meter does not take any measurement when the battery is low. Important: If battery is completely drained, fully charge the battery and launch the app to sync the meter before using it again.
. Sync the meter
Prior to first use, follow the steps below to connect the meter to the app on your mobile device to set your meter's time and date. 1. Enable Bluetooth on your iOS or Android device.
2. Press and hold the "Memory" button for three seconds to turn the meter on.
3. Select the model name "BG5xxxxxx" in the Bluetooth menu to pair and connect.
4. Launch the app to connect the meter to the app. The Bluetooth symbol " "will flash and
remain lit on the meter.
Note: Repeat steps 1-‐4 when switching to a different iOS or Androiddevice, making sure to un-‐pair or forget the meter on the previous device.
. Scan the test strip vial
Caution: Please carefully read and follow the instructions below to avoid getting inaccurate test results and/or test strips tracking errors. Connect your mobile device to the Internet and open the Gluco-‐Smart App. When the glucose meter is connected to the mobile device, scan the QR code on the top of the iHealth test strip vial to calibrate the test strips wit the meter. You must scan the QR code each time a new vial is opened.
When all 25 strips in a vial have been used, appears on the meter to alert you that it is
time to open a new vial, and the meter will shut off automatically. The meter does not take any measurement when "Er d" appears on the meter.
. Test blood glucose level
If you have synced your meter to the app on your mobile device, scanned the QR code of a test strip vial, and want to take a reading with the app: [1] Make sure Bluetooth is turned on to connect the meter to the app on your mobile device. If you have synced your meter to the app on your mobile device, scanned the QR code of test strip vial, and want to take a reading without the app launched: Skip step [1]. [2] Insert the test strip into the meter's strip port. Insert the test strip into the strip port with the contact bars facing toward you.
[3] Prepare the lancing device.
① Snap off the lancet device cap ② Insert a new lancet firmly into the lancing holder cup
③ Twist the lancet cover off ④ Replace the lancing device cap ⑤ Set the lancing level ⑥ Cock the handle until it clicks
[4] Obtain a blood sample. Press the lancing device against the site to be lanced. Press the release button to puncture the site. Gently squeeze your finger until a drop of blood forms. Wipe away the first blood drop and squeeze until a second small blood drops forms.
[5] Apply the blood sample to the test strip. Quickly apply the blood sample to the absorbent hole (tip) of the test strip. Make sure the confirmation window of the test strip is completely filled with the blood sample.
Quickly remove your finger from the test strip when the countdown (from 5 to 1) begins on the meter display, or when you hear a sound alert from your mobile device.
[6] Read the test results. -‐If the meter is not connected to the app, the test result will appear on the meter after counting down from 5 to 1.
-‐ If the meter is connected to the app, the test result will appear on the app.
[7] Discard the used test strip and lancet. Remove the used test strip from the meter using a small amount of tissue paper. Discard the used test strip and lancet properly. (Tip: Prior to disposal, stick the lancet into the cover)
DATA SYNCING
The meter can save up to 500 of the most recent blood glucose test results. When the meter needs to save a new test result and has already stored 500 test results, the oldest test result will be overwritten by the new test result. When the meter is connected to the app on your mobile device, tap the "Upload" button to upload the saved data from the meter to the app.
CUSTOMER SERVICE
If you need additional iHealth test strips, iHealth control solution, lancing devices, and lancets, please visit www.ihealthlabs.com, or you may contact customer service at: USA: Tel: +1-‐855-‐816-‐7705 (8:30 A.M. – 5:30 P.M. PST, Monday to Friday except holidays) Email: [email protected] Europe: Tel: +33(0)1 44 94 04 81 (9:00 A.M. – 5:30 P.M., Monday to Friday except holidays)
Email: [email protected] For additional product information, please go to www.ihealthlabs.com. IMPORTANT SAFETY INSTRUCTIONS: Use only iHealth test strips. The meter and lancing device are for single patient use only. Don’t share them with anyone, including other family members. Please refer to the iHealth Wireless Smart Gluco-‐Monitoring System Owner's Manual for more information. iHealth is a trademark of iHealth Labs Inc. ©2013 iHealth Labs Inc. All rights reserved. Manufactured for iHealth Labs Inc., Mountain View, CA 94043, USA.