22
Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications - Americas 34-XY-03-05 August 2008 Function The Wireless Base Radio (WBR) is part of the XYR 5000 family of wireless products. It combines an RF transceiver and the interface to a SCADA, DCS, or data acquisition device. The WBR Radio Frequency (RF) transceiver communicates in a digital protocol, using Frequency Hopping Spread Spectrum (FHSS). FHSS ensures data integrity by continually switching the carrier wave over a wide range of frequencies. Each Wireless Base Radio can communicate with up to 100 field units. As part of its diagnostic capability, the Wireless Base Radio can identify and report field unit out of spec conditions, and low battery alarms. Multiple outputs are available. The Wireless Base Radio is easily configured using the local pushbuttons and display. Enjoy the benefits of wireless technology today: Improve Product Quality Ensure High Uptime Reduce Maintenance and Operational Costs Meet Regulatory Requirements Enhance Flexibility Model Base Radio Model # INPUT OUTPUT WBR WBH Up to 100 field units Up to 100 field units RS-485 Modbus 4-20 mA (Quad Analog Output module) RS-232

Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications - Americas 34-XY-03-05 August 2008

Function

The Wireless Base Radio (WBR) is part of the XYR

5000 family of wireless products. It combines an RF

transceiver and the interface to a SCADA, DCS, or

data acquisition device. The WBR Radio Frequency

(RF) transceiver communicates in a digital protocol,

using Frequency Hopping Spread Spectrum (FHSS).

FHSS ensures data integrity by continually switching

the carrier wave over a wide range of frequencies.

Each Wireless Base Radio can communicate with up

to 100 field units. As part of its diagnostic capability,

the Wireless Base Radio can identify and report field

unit out of spec conditions, and low battery alarms.

Multiple outputs are available. The Wireless Base

Radio is easily configured using the local pushbuttons

and display.

Enjoy the benefits of wireless technology today:

Improve Product Quality

Ensure High Uptime

Reduce Maintenance and Operational Costs

Meet Regulatory Requirements

Enhance Flexibility

Model

Base Radio

Model # INPUT OUTPUT

WBR

WBH

Up to 100 field units

Up to 100 field units

RS-485 Modbus

4-20 mA (Quad Analog Output module)

RS-232

HFS Catalog_Without Tab_HighRes.pdf 1740 6/8/2011 12:42:19 PM

Page 2: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 2

Wireless General Specifications

Wireless Communication 902 MHz – 928 MHz Frequency Hopping Spread Spectrum (FHSS)

FCC certified ISM license-free band.

Every data block transmitted is verified (CRC check) and acknowledged by the Base Radio.

RF Transmit Power 31 mW, 17.8 mW typical.

Data Rate Configurable: 4.8 Kbps, 19.2 Kbps, or 76.8 Kbps.

Scan Rate 20 seconds @ 4.8 Kbps, 5 seconds @ 19.2 Kbps, 1.4 seconds @ 76.8 Kbps.

Antenna External 3” omni-directional, ½ wave, dipole.

Remote High Gain Omnidirectional

Available by itself, or with a lightening suppressor and 10 or 25 feet of cable.

Length: 65”.

Gain: 6 dBd (less cable loss 0.04 dBm/ft).

Weight: 6 lbs.

Polarization: Vertical.

Material: Precision copper clad radiators enclosed in high density fiberglass, UV protected.

Mounting: Heavy wall gold anodized 1 ¼” aluminum with brackets.

Base Radio coaxial cable

Factory installed coax cable in 10 of 25 foot lengths

RG Type 8/U, Series Type RF 400, 10 AWG.

Signal Range Up to 2000 feet (600 meters) from Base Radio with clear line of sight.*

Up to 5000 feet (1500 meters) from Base Radio with clear line of sight.*

*Actual range may vary depending on site topography. Yagi antenna option on field unit will increase signal range.

Device Configuration

Parameter Configuration RF Channel Setup: 1 to 16.

Field Device Baud Rate: 4.8 Kbps, 19.2 Kbps, 76.8 Kbps.

Serial Output: 9.6 Kbps, 19.2 Kbps, 38.4 Kbps, 57.6 Kbps, 115 Kbps.

Number of field units: 1 to 100.

Output: • RS-485.

• 4 – 20 mA (analog output via Quad output modules).

• RS-232 (optional converter required).

Configuration Panel Integrated LCD display with membrane switch buttons for local configuration.

LCD display is 7-digit (alternating) high contrast, anti-reflective monochrome.

Display cycles between field unit status, and RF status.

HFS Catalog_Without Tab_HighRes.pdf 1741 6/8/2011 12:42:19 PM

Page 3: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 3

Self Diagnostics

Self-checking software and hardware that identifies and reports out of spec conditions, and field unit low battery voltage.

Operating Conditions

Humidity 95% RH (non-condensing).

Temperature Ambient Electronics:

Display (Full visibility):

Display (Reduced visibility):

Storage:

-40 to +185°F (-40 to +40°/85°C) (see Approvals below)

-4 to +158°F (-20 to +70°C)

-40 to +185°F (-40 to +85°C)

-58 to +185°F (-50 to +85°C).

Electrical Specifications

Power connection

Signal connection

Two terminals, 22 AWG power supply wire (GND, 24V).

Two terminals, use 2 wire shielded and protected 16 AWG. Additional two terminals are supplied for linking base radios.

Grounding Earth grounding required.

Power Supply External Supply Voltage, 12 – 30 VDC @ 0.2A.

DIN rail mounted 120/240 VAC adapter (optional).

Physical Specifications

Electronic Housing Baked enamel aluminum housing.

Conduit Connection ¾”-NPTF.

Net weight 2.5 kgs (5 lbs).

Mounting Wall mount standard, or 2” pipe mounting bracket optional.

Approvals

Environmental protection NEMA 4X, IP 66

Combined FM/CSA FM – Explosion proof - Class I, Div. 1, Groups B,C,D, T5 (Ta=85°C), T6 (Ta=40C), Enclosure 4X

Dust-Ignition proof - Class II, III, Div. 1, Groups E,F,G, T5(Ta=85°C) T6 (Ta=40C), Enclosure 4X

CSA - Explosion proof - Class I, Div. 1, Groups B,C,D, T6(Ta=40°C), Enclosure 4X

Dust-Ignition proof - Class II, III, Div. 1, Groups E,F,G, T6(Ta=40°C), Enclosure 4X

CE CE EMC Conformity, ETSI EN 300 489-1

ATEX (applied for) Flameproof, Zone 1 - Ex II 2 G EEx d IIC T5, T6; Enclosure IP 66/67

Note: WBH radio is not approved for hazardous locations.

HFS Catalog_Without Tab_HighRes.pdf 1742 6/8/2011 12:42:19 PM

Page 4: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 4

Dimensions

3.04m/10’ Length

HFS Catalog_Without Tab_HighRes.pdf 1743 6/8/2011 12:42:19 PM

Page 5: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 5

Model Selection Guide

Model Selection Guides are subject to change and are inserted into the specifications as guidance only. Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at: http://hpsweb.honeywell.com/Cultures/en-US/Products/Instrumentation/ProductModelSelectionGuides/default.htm

Model Selection Guide34-XY-16-18 Issue 8

InstructionsSelect the desired key number. The arrow to the right marks the selection available.Make one selection from Table I. Select Table II options as desired.

Key Number I V_ _ _ - - _ _ _ _ _ _ - _ _ _ _ _ _ - _ _ _ _ - _ _

KEY NUMBER Availability

DescriptionWireless Base Radio (Dual Output) with Omni Directional AntennaWireless Base Radio (Dual Output) with High Gain Antenna

TABLE I - GATEWAY OPTIONSNo Selection Basic Wireless Gateway Package for TDC/TPS includes: - XYR SI-FTA card with embedded TDC/TPS firmware - 30 cm Power Adapter Card to XYR SI-FTA cable - XYR Configurator and documents in CD-ROMExtended Wireless Gateway Package for TDC/TPS includes: - XYR SI-FTA card with embedded TDC/TPS firmware - 30 cm Power Adapter Card to XYR SI-FTA cable - XYR Configurator and documents in CD-ROM - SI-IOP Serial Interface Card For TDC/TPS - Power Adapter Card used with XYR SI-FTA - 5 meters SI-IOP to XYR SI-FTA Cable

TABLE II - OPTIONSNone 2" Pipe Mounting Bracket None 120/240 VAC to 24 VDC 15 W DIN Rail Mounted Power Supply

_ _ _ _ 00

II IV

_ _ PW _ _

RS-485 to RS-232 DIN Rail Converter kit _ _ _ _ RS

III

00

G1

G2

_ _

Selection

None

WBRWBH

00 _ _ _ _

_ _ 00 _ _MB _ _ _ _

HFS Catalog_Without Tab_HighRes.pdf 1744 6/8/2011 12:42:19 PM

Page 6: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 6

WBR WBH

TABLE III - OUTPUT OPTIONSNo Options DIN Rail Mounted Quad 4-20 mA Output Module - 4 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 8 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 12 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 16 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 20 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 24 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 28 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 32 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 36 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 40 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 44 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 48 Analog Outputs No Options DIN Rail Mounted Discrete Output Module - 8 switch outputs DIN Rail Mounted Discrete Output Module - 16 switch outputs DIN Rail Mounted Discrete Output Module - 24 switch outputs DIN Rail Mounted Discrete Output Module - 32 switch outputs DIN Rail Mounted Discrete Output Module - 40 switch outputs DIN Rail Mounted Discrete Output Module - 48 switch outputs DIN Rail Mounted Discrete Output Module - 56 switch outputs DIN Rail Mounted Discrete Output Module - 64 switch outputs DIN Rail Mounted Discrete Output Module - 72 switch outputs DIN Rail Mounted Discrete Output Module - 80 switch outputs DIN Rail Mounted Discrete Output Module - 88 switch outputs DIN Rail Mounted Discrete Output Module - 96 switch outputs No Options DIN Rail Mounted Combined Analog/Discrete Output Module - 4 / 8 DIN Rail Mounted Combined Analog/Discrete Output Module - 8 / 16 DIN Rail Mounted Combined Analog/Discrete Output Module - 12 / 24 DIN Rail Mounted Combined Analog/Discrete Output Module - 16 / 32 DIN Rail Mounted Combined Analog/Discrete Output Module - 20 / 40 DIN Rail Mounted Combined Analog/Discrete Output Module - 24 / 48 DIN Rail Mounted Combined Analog/Discrete Output Module - 28 / 56 DIN Rail Mounted Combined Analog/Discrete Output Module - 32 / 64 DIN Rail Mounted Combined Analog/Discrete Output Module - 36 / 72 DIN Rail Mounted Combined Analog/Discrete Output Module - 40 / 80 DIN Rail Mounted Combined Analog/Discrete Output Module - 44 / 88 DIN Rail Mounted Combined Analog/Discrete Output Module - 48 / 96 * (Note - up to 25 output cards can be added to the base radio, in any combination ofboard type; one field measurement point can be mapped to multiple output points).

_ _ BC _ __ _ BB _ _

_ _ B7_ __ _ B8 _ __ _ B9 _ __ _ BA _ _

_ _ B3 _ __ _ B4 _ _

AA _ _ _ _AB _ _ _ _

_ _ B5 _ __ _ B6 _ _

AC _ _ _ __ _ 00 _ __ _ B1 _ __ _ B2 _ _

_ _ _ _ 00

00 _ _ _ _A1 _ _ _ _A2 _ _ _ _

A4 _ _ _ _A5 _ _ _ _A6 _ _ _ _A7 _ _ _ _A8 _ _ _ _A9 _ _ _ _

_ _ _ _CB_ _ _ _CC

A3 _ _ _ _

Selection

_ _ _ _C7_ _ _ _C8

Availability

_ _ _ _C4

_ _ _ _C1_ _ _ _C2_ _ _ _C3

_ _ _ _C5_ _ _ _C6

_ _ _ _C9_ _ _ _CA

HFS Catalog_Without Tab_HighRes.pdf 1745 6/8/2011 12:42:19 PM

Page 7: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 7

NOTE: APPROVAL SELECTION APPLIES ONLY TO BASE RADIOWBR WBH

TABLE V - CERTIFICATION OPTIONS

Location or Classification(1) No hazardous location approvals

Explosion proof Class I, Div. 1, Groups B,C,D, T5,T6Enclosure 4X

Dust- Class II, III, Div. 1, Groups E,F,G, T5,T6Ignition proof Enclosure 4X Explosion proof Class I, Div. 1, Groups B,C,D, T5

Enclosure 4XDust- Class II, III, Div. 1, Groups E,F,G, T5; Ignition proof Enclosure 4X

(2) ATEX* Flame proof, Ex II 2 G EEx d IIC T5, T6; Zone 1 Enclosure IP 65

(2) CE Nonhazardous CE EMC Conformity, ETSI EN 300 489-1, Locations EN 61326

* See ATEX installation requirements in the Operator's Manual.

(1) Select for North American 900 MHz base radio(2) Select for European 868 MHx base radio

3D

3X

9X

(1) Combined FM & CSA

AK

Approval Body Approval Type Selection Availability

Wireless Gateway Integration Accessories: May be ordered independently by the following part numbers:

SI-IOP Serial Interface Card For TDC/TPSPower Adapter Card used with XYR SI-FTA5 meters SI-IOP to XYR SI-FTA Cable30 cm Power Adapter Card to XYR SI-FTA cable

NOTE: Manuals are provided on CD with each shipment. Manuals may also be downloaded free of charge @http://hpsweb.honeywell.com/Cultures/en-US/Products/Instrumentation/xyr5000wireless/default.htm

50018509-00150018506-00150018505-00150018503-001Part Number

TABLE IV - HIGH GAIN ANTENNA SELECTION (Must select base radio cable and antenna option)Integral Omni Standard Base Radio coax cable (assembled to base radio) - 10 foot Base Radio coax cable (assembled to base radio) - 25 foot None No High Gain Antenna High Gain Antenna with no cable High Gain Antenna with lightning arrestor and 10 foot cable High Gain Antenna with lightning arrestor and 25 foot cable The base radio cable supplies 10 or 25 feet of cable. Then select just the antenna by itself, or the antenna with 10 or 25 feet of cable which comes with a lightning arrestor.

00 _ _

TW _ _TE _ _

_ _NA

_ _HC

_ _ 00

_ _HB_ _HA

HFS Catalog_Without Tab_HighRes.pdf 1746 6/8/2011 12:42:19 PM

Page 8: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 8

For More Information

Learn more about how Honeywell’s XYR 5000 WBR/WBH

Wireless Base Radio can reduce maintenance and

operational costs, visit our website

www.honeywell.com/ps/hfs or contact your Honeywell

account manager.

Honeywell Process Solutions

1860 West Rose Garden Lane

Phoenix, Arizona 85027

Tel: 1-800-423-9883 or 1-800-343-0228 www.honeywell.com/ps

34-XY-03-05August 2008 © 2010 Honeywell International Inc.

HFS Catalog_Without Tab_HighRes.pdf 1747 6/8/2011 12:42:19 PM

Page 9: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

Analog/Discrete Output Modules for the Base Radio Series XYR 5000 Specifications 34-XY-03-08 February 2008

Function

The Analog/Discrete Output Modules provide

field unit process/status data from the base

radio to the customer’s system. There are three

different modules available; the Analog Output

Module, the Discrete Output Module, and the

combined Analog/ Discrete Output Module.

The Analog Output Modules can be configured

to output the primary and secondary variables

from the field unit in 4 – 20 mA. The Discrete

Output Modules can be configured to open or

close based on:

Process variable thresholds

Field unit alarms (like low battery)

Enjoy the benefits of wireless technology today:

Improve Product Quality

Ensure High Uptime

Reduce Maintenance and Operational

Costs

Meet Regulatory Requirements

Enhance Flexibility

Honeywell

Base Radio

Output Modules

HFS Catalog_Without Tab_HighRes.pdf 1748 6/8/2011 12:42:19 PM

Page 10: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 Analog/Discrete Output Modules for the Base Radio 2

Analog Outputs

Outputs per Card 4 (Isolated Current Sink Outputs)

Current 3.1 to 23.5 mA, range selectable

Load Resistance 1000 ohms max. @ 24 Vdc; 500 ohms max. @ 12 Vdc

Isolation 2,200 Vrms between field and logic

Accuracy ± 0.1% of full scale reading at Reference Conditions (24° C, 75° F)

Additional ± 0.1% per 10°C (18° F) deviation from reference conditions

Discrete Output Switches

Outputs per Card 8 (Isolated Avalanche MOSFET Outputs)

Isolation 2,200 Vrms between field and logic

Operating Voltage 6 – 30 Vdc

On Resistance 9 m-ohms typical, 15 m-ohms maximum

Maximum Load Current 1 amp dc per point

Device Configuration

Parameter Configuration Wireless Management Toolkit required for parameter configuration

Analog Output Range: lower and upper range values

Analog Output Trim: Applies a user-defined one- or two-point correction curve to the actual value

Enable/Disable Failsafe for each output

Analog Output Failsafe: user selectable to 3.6 mA, 23 mA, or user specified value

Discrete Output Failsafe: open condition only

RS-485 address (1 per module)

Mapping of field unit process/status data

Operating/Storage Conditions

Temperature Ambient Electronics:

-40 to +185°F (-40 to +85°C)

Physical Specifications (DIN Rail Mounted)

Analog Module (4 AO) 3.8” high X 1.8” wide X 4.4” deep

Discrete Module (8 DO) 3.8” high X 2.7” wide X 4.4” deep

Analog/ Discrete Module

(4 AO/8 DO)

3.8” high X 2.7” wide X 4.4” deep

HFS Catalog_Without Tab_HighRes.pdf 1749 6/8/2011 12:42:19 PM

Page 11: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 Analog/Discrete Output Modules for the Base Radio 3

Model Selection Guide

Model Selection Guides are subject to change and are inserted into the specifications as guidance only. Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at: http://hpsweb.honeywell.com/Cultures/en-US/Products/Instrumentation/ProductModelSelectionGuides/default.htm

Model Selection Guide34-XY-16-18 Issue 7

InstructionsSelect the desired key number. The arrow to the right marks the selection available.Make one selection from Table I. Select Table II options as desired.

Key Number I V_ _ _ - - _ _ _ _ _ _ - _ _ _ _ _ _ - _ _ _ _ - _ _

KEY NUMBER Availability

DescriptionWireless Base Radio (Dual Output) with Omni Directional AntennaWireless Base Radio (Dual Output) with High Gain Antenna

TABLE I - GATEWAY OPTIONSNo Selection Basic Wireless Gateway Package for TDC/TPS includes: - XYR SI-FTA card with embedded TDC/TPS firmware - 30 cm Power Adapter Card to XYR SI-FTA cable - XYR Configurator and documents in CD-ROMExtended Wireless Gateway Package for TDC/TPS includes: - XYR SI-FTA card with embedded TDC/TPS firmware - 30 cm Power Adapter Card to XYR SI-FTA cable - XYR Configurator and documents in CD-ROM - SI-IOP Serial Interface Card For TDC/TPS - Power Adapter Card used with XYR SI-FTA - 5 meters SI-IOP to XYR SI-FTA Cable

TABLE II - OPTIONSNone 2" Pipe Mounting Bracket None 120/240 VAC to 24 VDC 15 W DIN Rail Mounted Power Supply

_ _ _ _ 00

II IV

_ _ PW _ _

RS-485 to RS-232 DIN Rail Converter kit _ _ _ _ RS

III

00

G1

G2

_ _

Selection

None

WBRWBH

00 _ _ _ _

_ _ 00 _ _MB _ _ _ _

HFS Catalog_Without Tab_HighRes.pdf 1750 6/8/2011 12:42:19 PM

Page 12: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 Analog/Discrete Output Modules for the Base Radio 4

WBR WBH

TABLE III - OUTPUT OPTIONSNo Options DIN Rail Mounted Quad 4-20 mA Output Module - 4 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 8 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 12 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 16 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 20 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 24 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 28 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 32 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 36 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 40 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 44 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 48 Analog Outputs No Options DIN Rail Mounted Discrete Output Module - 8 switch outputs DIN Rail Mounted Discrete Output Module - 16 switch outputs DIN Rail Mounted Discrete Output Module - 24 switch outputs DIN Rail Mounted Discrete Output Module - 32 switch outputs DIN Rail Mounted Discrete Output Module - 40 switch outputs DIN Rail Mounted Discrete Output Module - 48 switch outputs DIN Rail Mounted Discrete Output Module - 56 switch outputs DIN Rail Mounted Discrete Output Module - 64 switch outputs DIN Rail Mounted Discrete Output Module - 72 switch outputs DIN Rail Mounted Discrete Output Module - 80 switch outputs DIN Rail Mounted Discrete Output Module - 88 switch outputs DIN Rail Mounted Discrete Output Module - 96 switch outputs No Options DIN Rail Mounted Combined Analog/Discrete Output Module - 4 / 8 DIN Rail Mounted Combined Analog/Discrete Output Module - 8 / 16 DIN Rail Mounted Combined Analog/Discrete Output Module - 12 / 24 DIN Rail Mounted Combined Analog/Discrete Output Module - 16 / 32 DIN Rail Mounted Combined Analog/Discrete Output Module - 20 / 40 DIN Rail Mounted Combined Analog/Discrete Output Module - 24 / 48 DIN Rail Mounted Combined Analog/Discrete Output Module - 28 / 56 DIN Rail Mounted Combined Analog/Discrete Output Module - 32 / 64 DIN Rail Mounted Combined Analog/Discrete Output Module - 36 / 72 DIN Rail Mounted Combined Analog/Discrete Output Module - 40 / 80 DIN Rail Mounted Combined Analog/Discrete Output Module - 44 / 88 DIN Rail Mounted Combined Analog/Discrete Output Module - 48 / 96 * (Note - up to 25 output cards can be added to the base radio, in any combination ofboard type; one field measurement point can be mapped to multiple output points).

_ _ BC _ __ _ BB _ _

_ _ B7_ __ _ B8 _ __ _ B9 _ __ _ BA _ _

_ _ B3 _ __ _ B4 _ __ _ B5 _ __ _ B6 _ _

AC _ _ _ __ _ 00 _ __ _ B1 _ __ _ B2 _ _

A8 _ _ _ _A9 _ _ _ _AA _ _ _ _AB _ _ _ _

A4 _ _ _ _A5 _ _ _ _A6 _ _ _ _A7 _ _ _ _

_ _ _ _CB_ _ _ _CC

_ _ _ _ 00

00 _ _ _ _A1 _ _ _ _A2 _ _ _ _A3 _ _ _ _

Selection

_ _ _ _C7_ _ _ _C8

Availability

_ _ _ _C4

_ _ _ _C1_ _ _ _C2_ _ _ _C3

_ _ _ _C5_ _ _ _C6

_ _ _ _C9_ _ _ _CA

TABLE IV - HIGH GAIN ANTENNA SELECTION (Must select base radio cable and antenna option)Integral Omni Standard Base Radio coax cable (assembled to base radio) - 10 foot dBase Radio coax cable (assembled to base radio) - 25 foot dNone No High Gain Antenna cHigh Gain Antenna with no cable High Gain Antenna with lightning arrestor and 10 foot cable High Gain Antenna with lightning arrestor and 25 foot cable The base radio cable supplies 10 or 25 feet of cable. Then select just the antenna by itself, or the antenna with 10 or 25 feet of cable which comes with a lightning arrestor.

00 _ _

TW _ _TE _ _

_ _NA

_ _HC

_ _ 00

_ _HB_ _HA

HFS Catalog_Without Tab_HighRes.pdf 1751 6/8/2011 12:42:19 PM

Page 13: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 Analog/Discrete Output Modules for the Base Radio 5

WBR WBH

TABLE V - CERTIFICATION OPTIONS

Location or Classification(1) No hazardous location approvals

Explosion proof Class I, Div. 1, Groups B,C,D, T5,T6Enclosure 4X

Dust- Class II, III, Div. 1, Groups E,F,G, T5,T6Ignition proof Enclosure 4X Explosion proof Class I, Div. 1, Groups B,C,D, T5

Enclosure 4XDust- Class II, III, Div. 1, Groups E,F,G, T5; Ignition proof Enclosure 4X

(2) ATEX* Flame proof, Ex II 2 G EEx d IIC T5, T6; Zone 1 Enclosure IP 65

(2) CE Nonhazardous CE EMC Conformity, ETSI EN 300 489-1, Locations EN 61326

* See ATEX installation requirements in the Operator's Manual.

(1) Select for North American 900 MHz base radio(2) Select for European 868 MHx base radio

RESTRICTIONSRestriction Letter Not Available With

Selectioncd

3D

3X

Table Selection

9X

(1) Combined FM & CSA

AK

IV _ _HA, _ _HB, _ _HC

Available Only WithTable

IV TE_ _, TW_ _

Approval Body Approval Type Selection Availability

Wireless Gateway Integration Accessories: May be ordered independently by the following part numbers:

SI-IOP Serial Interface Card For TDC/TPSPower Adapter Card used with XYR SI-FTA5 meters SI-IOP to XYR SI-FTA Cable30 cm Power Adapter Card to XYR SI-FTA cable

NOTE: Manuals are provided on CD with each shipment. Manuals may also be downloaded free of charge @http://hpsweb.honeywell.com/Cultures/en-US/Products/Instrumentation/xyr5000wireless/default.htm

50018509-00150018506-00150018505-00150018503-001Part Number

HFS Catalog_Without Tab_HighRes.pdf 1752 6/8/2011 12:42:19 PM

Page 14: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 Analog/Discrete Output Modules for the Base Radio 6

For More Information

Learn more about how Honeywell’s XYR 5000

Analog/Discrete Output Modules for the Base Radio

can offer high-performance, visit our website

www.honeywell.com/ps/hfs or contact your

Honeywell account manager.

Honeywell Process Solutions

1860 West Rose Garden Lane

Phoenix, Arizona 85027

Tel: 1-800-423-9883 or 1-800-343-0228

www.honeywell.com/ps

34-XY-03-08 February 2008 © 2010 Honeywell International Inc.

HFS Catalog_Without Tab_HighRes.pdf 1753 6/8/2011 12:42:19 PM

Page 15: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 Wireless Base Radio Model WBR/WBH Specifications - Europe 34-XY-03-55 February 2008

Function

The Wireless Base Radio (WBR) is part of the XYR 5000

family of wireless products. It combines an RF transceiver

and the interface to a SCADA, DCS, or data acquisition

device. The WBR Radio Frequency (RF) transceiver

communicates in a digital protocol, using Frequency

Hopping Spread Spectrum (FHSS). FHSS ensures data

integrity by continually switching the carrier wave over a

wide range of frequencies. Each Wireless Base Radio can

communicate with up to 42 field units. As part of its

diagnostic capability, the Wireless Base Radio can identify

and report field unit out of spec conditions, and low battery

alarms. Multiple outputs are available. The Wireless Base

Radio is easily configured using the local pushbuttons and

display.

Enjoy the benefits of wireless technology today:

Improve Product Quality

Ensure High Uptime

Reduce Maintenance and Operational Costs

Meet Regulatory Requirements

Enhance Flexibility

Model

Base Radio

Model # INPUTS OUTPUT

WBR

WBH

Up to 42 field units

Up to 42 field units

RS-485 Modbus

4-20 mA (Quad Analog Output module)

RS-232

Base Radios

Wireless Transmitters

RS-485 Modbus 4-20mA RS-232

Wireless ManagementToolkit

HFS Catalog_Without Tab_HighRes.pdf 1754 6/8/2011 12:42:19 PM

Page 16: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 2

Wireless General Specifications

Wireless Communication 869.4 to 869.65 MHz Frequency Hopping Spread Spectrum (FHSS)

Every data block transmitted is verified (CRC check) and acknowledged by the Base Radio.

RF Transmit Power 10 dBm (10 mW), 6-8 dBm typical (7.8 to 9 dBm)

Data Rate 4.8 Kbps.

Update 5 seconds @ 4.8 Kbps.

Antenna External 3” omni-directional, ½ wave, dipole.

Remote High Gain Omnidirectional

Available by itself, or with a lightening suppressor and 10 or 25 feet of cable.

Length: 65”.

Gain: 6 dBd (less cable loss 0.04 dBm/ft).

Weight: 6 lbs.

Polarization: Vertical.

Material: Precision copper clad radiators enclosed in high density fiberglass, UV protected.

Mounting: Heavy wall gold anodized 1 ¼” aluminium with brackets.

Base Radio coaxial cable

Factory installed coax cable in 10 of 25 foot lengths

RG Type 8/U, Series Type RF 400, 10 AWG.

Signal Range Up to 2000 feet (600 meters) from Base Radio with clear line of sight.*

Up to 5000 feet (1500 meters) from Base Radio with clear line of sight.*

*Actual range may vary depending on site topography. Yagi antenna option on field unit will increase signal range.

Device Configuration

Parameter Configuration RF Channel Setup: 1 to 4.

Field Device Baud Rate: 4.8 Kbps.

Serial Output: 9.6 Kbps, 19.2 Kbps, 38.4 Kbps, 57.6 Kbps, 115 Kbps.

Number of field units: 1 to 42.

Output: • RS-485.

• 4 – 20 mA (analog output via Quad output modules).

• RS-232 (optional converter required).

Configuration Panel Integrated LCD display with membrane switch buttons for local configuration.

LCD display is 7-digit (alternating) high contrast, anti-reflective monochrome.

Display cycles between field unit status, and RF status.

HFS Catalog_Without Tab_HighRes.pdf 1755 6/8/2011 12:42:19 PM

Page 17: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 3

Self Diagnostics

Self-checking software and hardware that identifies and reports out of spec conditions, and field unit low battery voltage.

Operating Conditions

Humidity 95% RH (non-condensing).

Temperature Ambient Electronics:

Display (Full visibility):

Display (Reduced visibility):

Storage:

-40 to +185°F (-40 to +40°/85°C) (see Approvals below)

-4 to +158°F (-20 to +70°C)

-40 to +185°F (-40 to +85°C)

-58 to +185°F (-50 to +85°C).

Electrical Specifications

Power connection

Signal connection

Two terminals, 22 AWG power supply wire (GND, 24V).

Two terminals, use 2 wire shielded and protected 16 AWG. Additional two terminals are supplied for linking base radios.

Grounding Earth grounding required.

Power Supply External Supply Voltage, 12 – 30 VDC @ 0.2A.

DIN rail mounted 120/240 VAC adapter (optional).

Physical Specifications

Electronic Housing Baked enamel aluminum housing.

Conduit Connection ¾”-NPTF.

Net weight 2.5 kg (5 lbs).

Mounting Wall mount standard, or 2” pipe mounting bracket optional.

Approvals

Environmental protection NEMA 4X, IP 66

Combined FM/CSA FM – Explosion proof - Class I, Div. 1, Groups B,C,D, T5 (Ta=85°C), T6 (Ta=40C), Enclosure 4X

Dust-Ignition proof - Class II, III, Div. 1, Groups E,F,G, T5(Ta=85°C) T6 (Ta=40C), Enclosure 4X

CSA - Explosion proof - Class I, Div. 1, Groups B,C,D, T6(Ta=40°C), Enclosure 4X

Dust-Ignition proof - Class II, III, Div. 1, Groups E,F,G, T6(Ta=40°C), Enclosure 4X

CE CE EMC Conformity, ETSI EN 300 489-1

ATEX (applied for) Flameproof, Zone 1 - Ex II 2 G EEx d IIC T5, T6; Enclosure IP 66/67

Note: WBH radio is not approved for hazardous locations.

HFS Catalog_Without Tab_HighRes.pdf 1756 6/8/2011 12:42:19 PM

Page 18: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 4

DIMENSIONS – [mm] inches

3.04m/10’ Length

HFS Catalog_Without Tab_HighRes.pdf 1757 6/8/2011 12:42:19 PM

Page 19: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 5

Model Selection Guide

Model Selection Guides are subject to change and are inserted into the specifications as guidance only. Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at: http://hpsweb.honeywell.com/Cultures/en-US/Products/Instrumentation/ProductModelSelectionGuides/default.htm

Model Selection Guide34-XY-16-18 Issue 7

InstructionsSelect the desired key number. The arrow to the right marks the selection available.Make one selection from Table I. Select Table II options as desired.

Key Number I V_ _ _ - - _ _ _ _ _ _ - _ _ _ _ _ _ - _ _ _ _ - _ _

KEY NUMBER Availability

DescriptionWireless Base Radio (Dual Output) with Omni Directional AntennaWireless Base Radio (Dual Output) with High Gain Antenna

TABLE I - GATEWAY OPTIONSNo Selection Basic Wireless Gateway Package for TDC/TPS includes: - XYR SI-FTA card with embedded TDC/TPS firmware - 30 cm Power Adapter Card to XYR SI-FTA cable - XYR Configurator and documents in CD-ROMExtended Wireless Gateway Package for TDC/TPS includes: - XYR SI-FTA card with embedded TDC/TPS firmware - 30 cm Power Adapter Card to XYR SI-FTA cable - XYR Configurator and documents in CD-ROM - SI-IOP Serial Interface Card For TDC/TPS - Power Adapter Card used with XYR SI-FTA - 5 meters SI-IOP to XYR SI-FTA Cable

TABLE II - OPTIONSNone 2" Pipe Mounting Bracket None 120/240 VAC to 24 VDC 15 W DIN Rail Mounted Power Supply

_ _ _ _ 00

II IV

_ _ PW _ _

RS-485 to RS-232 DIN Rail Converter kit _ _ _ _ RS

III

00

G1

G2

_ _

Selection

None

WBRWBH

00 _ _ _ _

_ _ 00 _ _MB _ _ _ _

HFS Catalog_Without Tab_HighRes.pdf 1758 6/8/2011 12:42:19 PM

Page 20: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 6

WBR WBH

TABLE III - OUTPUT OPTIONSNo Options DIN Rail Mounted Quad 4-20 mA Output Module - 4 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 8 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 12 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 16 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 20 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 24 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 28 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 32 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 36 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 40 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 44 Analog Outputs DIN Rail Mounted Quad 4-20 mA Output Module - 48 Analog Outputs No Options DIN Rail Mounted Discrete Output Module - 8 switch outputs DIN Rail Mounted Discrete Output Module - 16 switch outputs DIN Rail Mounted Discrete Output Module - 24 switch outputs DIN Rail Mounted Discrete Output Module - 32 switch outputs DIN Rail Mounted Discrete Output Module - 40 switch outputs DIN Rail Mounted Discrete Output Module - 48 switch outputs DIN Rail Mounted Discrete Output Module - 56 switch outputs DIN Rail Mounted Discrete Output Module - 64 switch outputs DIN Rail Mounted Discrete Output Module - 72 switch outputs DIN Rail Mounted Discrete Output Module - 80 switch outputs DIN Rail Mounted Discrete Output Module - 88 switch outputs DIN Rail Mounted Discrete Output Module - 96 switch outputs No Options DIN Rail Mounted Combined Analog/Discrete Output Module - 4 / 8 DIN Rail Mounted Combined Analog/Discrete Output Module - 8 / 16 DIN Rail Mounted Combined Analog/Discrete Output Module - 12 / 24 DIN Rail Mounted Combined Analog/Discrete Output Module - 16 / 32 DIN Rail Mounted Combined Analog/Discrete Output Module - 20 / 40 DIN Rail Mounted Combined Analog/Discrete Output Module - 24 / 48 DIN Rail Mounted Combined Analog/Discrete Output Module - 28 / 56 DIN Rail Mounted Combined Analog/Discrete Output Module - 32 / 64 DIN Rail Mounted Combined Analog/Discrete Output Module - 36 / 72 DIN Rail Mounted Combined Analog/Discrete Output Module - 40 / 80 DIN Rail Mounted Combined Analog/Discrete Output Module - 44 / 88 DIN Rail Mounted Combined Analog/Discrete Output Module - 48 / 96 * (Note - up to 25 output cards can be added to the base radio, in any combination ofboard type; one field measurement point can be mapped to multiple output points).

_ _ BC _ __ _ BB _ _

_ _ B7_ __ _ B8 _ __ _ B9 _ __ _ BA _ _

_ _ B3 _ __ _ B4 _ __ _ B5 _ __ _ B6 _ _

AC _ _ _ __ _ 00 _ __ _ B1 _ __ _ B2 _ _

A8 _ _ _ _A9 _ _ _ _AA _ _ _ _AB _ _ _ _

A4 _ _ _ _A5 _ _ _ _A6 _ _ _ _A7 _ _ _ _

_ _ _ _CB_ _ _ _CC

_ _ _ _ 00

00 _ _ _ _A1 _ _ _ _A2 _ _ _ _A3 _ _ _ _

Selection

_ _ _ _C7_ _ _ _C8

Availability

_ _ _ _C4

_ _ _ _C1_ _ _ _C2_ _ _ _C3

_ _ _ _C5_ _ _ _C6

_ _ _ _C9_ _ _ _CA

TABLE IV - HIGH GAIN ANTENNA SELECTION (Must select base radio cable and antenna option)Integral Omni Standard Base Radio coax cable (assembled to base radio) - 10 foot dBase Radio coax cable (assembled to base radio) - 25 foot dNone No High Gain Antenna cHigh Gain Antenna with no cable High Gain Antenna with lightning arrestor and 10 foot cable High Gain Antenna with lightning arrestor and 25 foot cable The base radio cable supplies 10 or 25 feet of cable. Then select just the antenna by itself, or the antenna with 10 or 25 feet of cable which comes with a lightning arrestor.

00 _ _

TW _ _TE _ _

_ _NA

_ _HC

_ _ 00

_ _HB_ _HA

HFS Catalog_Without Tab_HighRes.pdf 1759 6/8/2011 12:42:19 PM

Page 21: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 7

WBR WBH

TABLE V - CERTIFICATION OPTIONS

Location or Classification(1) No hazardous location approvals

Explosion proof Class I, Div. 1, Groups B,C,D, T5,T6Enclosure 4X

Dust- Class II, III, Div. 1, Groups E,F,G, T5,T6Ignition proof Enclosure 4X Explosion proof Class I, Div. 1, Groups B,C,D, T5

Enclosure 4XDust- Class II, III, Div. 1, Groups E,F,G, T5; Ignition proof Enclosure 4X

(2) ATEX* Flame proof, Ex II 2 G EEx d IIC T5, T6; Zone 1 Enclosure IP 65

(2) CE Nonhazardous CE EMC Conformity, ETSI EN 300 489-1, Locations EN 61326

* See ATEX installation requirements in the Operator's Manual.

(1) Select for North American 900 MHz base radio(2) Select for European 868 MHx base radio

RESTRICTIONSRestriction Letter Not Available With

Selectioncd

3D

3X

Table Selection

9X

(1) Combined FM & CSA

AK

IV _ _HA, _ _HB, _ _HC

Available Only WithTable

IV TE_ _, TW_ _

Approval Body Approval Type Selection Availability

Wireless Gateway Integration Accessories: May be ordered independently by the following part numbers:

SI-IOP Serial Interface Card For TDC/TPSPower Adapter Card used with XYR SI-FTA5 meters SI-IOP to XYR SI-FTA Cable30 cm Power Adapter Card to XYR SI-FTA cable

NOTE: Manuals are provided on CD with each shipment. Manuals may also be downloaded free of charge @http://hpsweb.honeywell.com/Cultures/en-US/Products/Instrumentation/xyr5000wireless/default.htm

50018509-00150018506-00150018505-00150018503-001Part Number

HFS Catalog_Without Tab_HighRes.pdf 1760 6/8/2011 12:42:19 PM

Page 22: Wireless Base Radio Series XYR 5000, Model WBR/WBH Specifications

XYR 5000 WBR/WBH Wireless Base Radio 8

For More Information

Learn more about how Honeywell’s XYR 5000

WBR/WBH Wireless Base Radio can be easily

configured and can offer high-performance, visit our

website www.honeywell.com/ps/hfs or contact your

Honeywell account manager.

Honeywell Process Solutions

1860 West Rose Garden Lane

Phoenix, Arizona 85027

Tel: 1-800-423-9883 or 1-800-343-0228

www.honeywell.com/ps

34-XY-03-55February 2008 © 2010 Honeywell International Inc.

HFS Catalog_Without Tab_HighRes.pdf 1761 6/8/2011 12:42:19 PM