Product Windsock Mast Type M1G
Type Aluminium; ground mounting; complete with swivel arm
Rev 1.0 © Windsock Company Limited 2018
About Windsock Com pany
Windsock Company specialise in the manufacture and supply of windsocks and windsock masts. Our windsocks are manufactured in the United Kingdom and sold throughout the world for use in a wide range of aviation, safety and industrial applications.
Windsock Mast Type M1G
- Basic ground m ount ed windsock mast for in land use.- Suitable for windsocks with a maximum 24 inch (61 cms) diameter
mouth (depending on mast type - refer to table).- Aluminium with durable white powder paint finish.- Swivel arm allowing windsock to rotate 360 degrees.- Hinged base plate (galvanised steel) and ground anchors for setting
into wet concrete.- Straightforward installation for a competent builder.
Windsock Mast Type M1G Applicat ions
Aviat ion: Small airfields; private landing strips; helicopter landing areas; parachute schools; microlight clubs.
Indust r ial Safet y: Oil, gas and chemical storage; water and sewage treatment works; refrigeration plants; recycling plants; general weather observation; emergency planning equipment.
Var iables
Refer to the tables on pages 2 to 4 to select the right mast for your application.
Height : Our M1G type masts come in heights 3m to 8m.
Sect ion sizes: Variations in section sizes to cope with different conditions.
Windsock sizes: The tables give a recommended maximum size of windsock for each mast type.
Ot her Mount ing Opt ions
This basic mast system is available as a wall mount option - refer to product data sheet M1W.
We can also supply these masts without the base plate should you wish to engineer your own fixing solution to suit circumstances at site.
Pict ures
Top to bottom: 6m mast with 4ft (1.2m) windsock; swivel arm; hinged base.
PRODUCTDATA
Page 1 of 5
PRODUCTDATA
Page 2 of 5
Product Windsock Mast Type M1G
Type Aluminium; ground mounting; complete with swivel arm
Rev 1.0 © Windsock Company Limited 2018
GEOGRAPHICAL LOCATIONS
Inland GL1
Coastal - not suitable GL2
Offshore - not suitable GL3
WEATHER CONDITIONS
Calm to moderate WC1
Moderate to occasionally harsh WC2
Harsh to extreme - not suitable WC3
3m 4m 5m 5m
Part number M1G-3m-1 M1G-4m-1 M1G-5m-1 M1G-5m-1HD
Recommended maximum windsock size - length x dia. mouth 3ft x 15ins. 4ft x 15ins. 4ft x 15ins. 6ft x 18ins.
Mast - number of sections 1 1 1 1
Section sizes - outside diameter x wall thickness (dims in mm) 60 x 3 60 x 3 60 x 3 90 x 3
Estimated foundation size - width x width x depth (dims in cms) 65 x 65 x 50 65 x 65 x 50 65 x 65 x 50 80 x 80 x 60
Max wind speed for 15 ins / 38 cms dia. mouth windsock (mph) 100 97 80 92
Max wind speed for 18 inch / 46 cms dia. mouth windsock (mph) 100 90 76 88
Max wind speed for 24 inch / 61 cms dia. mouth windsock (mph) n/a 78 66 80
Geographical location suitability (refer to table above) GL1 GL1 GL1 GL1
Weather conditions suitability (refer to table above) WC1 / WC2 WC1 / WC2 WC1 / WC2 WC1 / WC2
The above tables are intended as a guide and should be read in conjunction with the windsock size and wind speed data in the table below. If in any doubt please call for technical assistance on 01245 230 700
Not e:
Most popular highlighted orange and normally used with 15 inch diameter mouth windsock.
Recom m ended m axim um w indsock size is based on combination of practicality and reducing wind loading whilst maintaining largest windsock size.
Est im at ed concret e foundat ion size is based on installation into compacted, established, soil with a minimum soil bearing pressure of approximately 75Kn/square metre. If in doubt consult a structural engineer or ground works specialist.
Maxim um w ind speed assumes that these conditions will be occasional and non sustained.
n/a = data not available at time of publication.
PRODUCTDATA
Page 3 of 5
Product Windsock Mast Type M1G
Type Aluminium; ground mounting; complete with swivel arm
Rev 1.0 © Windsock Company Limited 2018
6m 6m 6m
Part number M1G-6m-1 M1G-6m-2 M1G-6m-1HD
Recommended maximum windsock size - length x dia. mouth 6ft x 18ins 6ft x 18ins 8ft x 24ins
Mast - number of sections 1 2 1
Section sizes - outside diameter x wall thickness (dims in mm) 60 x 3 60 x 3 + 60 x 3 90 x 3
Estimated foundation size - width x width x depth (dims in cms) 80 x 80 x 60 80 x 80 x 60 80 x 80 x 60
Max wind speed for 15 ins / 38 cms dia. mouth windsock (mph) 70 70 92
Max wind speed for 18 inch / 46 cms dia. mouth windsock (mph) 66 66 88
Max wind speed for 24 inch / 61 cms dia. mouth windsock (mph) 59 59 80
Geographical location suitability (refer to table above) GL1 GL1 GL1
Weather conditions suitability (refer to table above) WC1 / WC2 WC1 / WC2 WC1 / WC2
GEOGRAPHICAL LOCATIONS
Inland GL1
Coastal - not suitable GL2
Offshore - not suitable GL3
WEATHER CONDITIONS
Calm to moderate WC1
Moderate to occasionally harsh WC2
Harsh to extreme - not suitable WC3
The above tables are intended as a guide and should be read in conjunction with the windsock size and wind speed data in the table below. If in any doubt please call for technical assistance on 01245 230 700
Not e:
Most popular highlighted orange and normally used with 15 inch diameter mouth windsock.
Recom m ended m axim um w indsock size is based on combination of practicality and reducing wind loading whilst maintaining largest windsock size.
Est im at ed concret e foundat ion size is based on installation into compacted, established, soil with a minimum soil bearing pressure of approximately 75Kn/square metre. If in doubt consult a structural engineer or ground works specialist.
Maxim um w ind speed assumes that these conditions will be occasional and non sustained.
n/a = data not available at time of publication.
Product Windsock Mast Type M1G
Type Aluminium; ground mounting; complete with swivel arm
Rev 1.0 © Windsock Company Limited 2018
PRODUCTDATA
Page 4 of 5
7m 7m 8m 8m
Part number M1G-7m-2 M1G-7m-2HD M1G-8m-2 M1G-8m-2HD
Recommended maximum windsock size - length x dia. mouth 5ft x 15ins 8ft x 24ins. 5ft x 15ins. 8ft x 24ins.
Mast - number of sections 2 2 2 2
Section sizes - outside diameter x wall thickness (dims in mm) 60x3 + 60x3 90x3 + 60x3 60x3 + 60x3 90x3 + 60x3
Estimated foundation size - width x width x depth (dims in cms) 80 x 80 x 60 80 x 80 x 60 80 x 80 x 60 80 x 80 x 60
Max wind speed for 15 ins / 38 cms dia. mouth windsock (mph) n/a n/a n/a 76
Max wind speed for 18 inch / 46 cms dia. mouth windsock (mph) n/a n/a n/a 74
Max wind speed for 24 inch / 61 cms dia. mouth windsock (mph) n/a n/a n/a 67
Geographical location suitability (refer to table above) GL1 GL1 GL1 GL1
Weather conditions suitability (refer to table above) WC1 / WC2 WC1 / WC2 WC1 / WC2 WC1 / WC2
GEOGRAPHICAL LOCATIONS
Inland GL1
Coastal - not suitable GL2
Offshore - not suitable GL3
WEATHER CONDITIONS
Calm to moderate WC1
Moderate to occasionally harsh WC2
Harsh to extreme - not suitable WC3
The above tables are intended as a guide and should be read in conjunction with the windsock size and wind speed data in the table below. If in any doubt please call for technical assistance on 01245 230 700
Not e:
Most popular highlighted orange and normally used with 15 inch diameter mouth windsock.
Recom m ended m axim um w indsock size is based on combination of practicality and reducing wind loading whilst maintaining largest windsock size.
Est im at ed concret e foundat ion size is based on installation into compacted, established, soil with a minimum soil bearing pressure of approximately 75Kn/square metre. If in doubt consult a structural engineer or ground works specialist.
Maxim um w ind speed assumes that these conditions will be occasional and non sustained.
n/a = data not available at time of publication.
Windsock Com pany Lt d
1 School Road
Toot Hill
Ongar
Essex
CM5 9PU
United Kingdom
Tel : +44 (0) 1245 230 700
Email : [email protected]
Web : www.windsockcompany.co.uk
Windsock Company Ltd have taken reasonable care in compiling the information contained within this literature. All recommendations concerning the use of our products are made without guarantee as site, climatic and environmental conditions are beyond the control of Windsock Company Ltd. It is the customer?s responsibility to ensure that the product is fit for its intended purpose and that the actual conditions in the location of use are suitable. Windsock Company pursues a policy of continuous product development and reserves the right to amend specifications without prior notice.