Copyright © 2014 EMC Corporation. All Rights Reserved. Windows Host Installation and Integration for Block Upon completion of this module, you should be able to: Identify Windows connectivity limits and guidelines Describe the implementation of VNX Fibre Channel connections to a Windows host Describe the implementation of VNX iSCSI connections to a Windows host Windows Host Installation and Integration for Block 1

Windows Host Installation and Integration for Block

  • Upload
    vic

  • View
    59

  • Download
    1

Embed Size (px)

DESCRIPTION

Windows Host Installation and Integration for Block. Upon completion of this module, you should be able to: Identify Windows connectivity limits and guidelines Describe the implementation of VNX Fibre Channel connections to a Windows host - PowerPoint PPT Presentation

Citation preview

Page 1: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Host Installation and Integration for Block

Upon completion of this module, you should be able to:• Identify Windows connectivity limits and guidelines• Describe the implementation of VNX Fibre Channel

connections to a Windows host• Describe the implementation of VNX iSCSI connections to a

Windows host

Windows Host Installation and Integration for Block 1

Page 2: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Host Installation and Integration for Block

This lesson covers the following topics:• Windows system limits and guidelines• Windows HBA utilities• Windows data alignment

Lesson 1: Windows Storage Connectivity

Windows Host Installation and Integration for Block 2

Page 3: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Connectivity: Requirements• One or more VNX storage systems• One or more Windows hosts• Supported HBAs, HBA drivers, switches and cables• Correctly configured switch zoning• Correctly configured network• A management station in the environment

Supported host and OS Supported browser Supported JRE Network connectivity to storage systems

3Windows Host Installation and Integration for Block

Page 4: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Connectivity: Best PracticesUse storage system-based RAID

RAID type should be based on Application I/O pattern

Use basic disks

8 kB page size for MS 2007 Exchange and 16kB for MS 2010 Exchange

Align LUN on a 1024 kB boundary with Diskpart when needed

4Windows Host Installation and Integration for Block

Page 5: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

OneCommand Manager: Port Information Tab

Windows Host Installation and Integration for Block 5

Page 6: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

OneCommand Manager: Target Mapping tab

6Windows Host Installation and Integration for Block

Page 7: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Qlogic SANsurfer: Information

VNX port WWPN

7Windows Host Installation and Integration for Block

Page 8: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Data Alignment• Alignment of data to LUN structure• Important when OS writes data to beginning of LUN• Misaligned data

causes disk crossings may not allow stripe alignment of large, uncached writes

• Windows 2008 and 2012 automatically aligns partitions at the 1 MB boundary no user intervention is required Refer to Microsoft KB Article 929491

8Windows Host Installation and Integration for Block

Page 9: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Aligning Data with diskpart

2,048 sectors (specified with diskpart) reserved by Windows 4KB user data block

First 5 stripes on a 4+1 R5 LUN

9Windows Host Installation and Integration for Block

Page 10: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Disk Alignment: Diskpart on a Windows 2008

10Windows Host Installation and Integration for Block

Page 11: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Host Installation and Integration for Block

During this lesson the following topics were covered:• Windows system limits and guidelines• Windows HBA utilities• Windows data alignment

Lesson 1: Summary

Windows Host Installation and Integration for Block 11

Page 12: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Host Installation and Integration for Block

This lesson covers the following topics:• VNX Fibre Channel connections to a Windows Host• VNX FCoE connections to a Windows Host• VNX iSCSI connections to a Windows Host

Lesson 2: Windows FC and iSCSI Connectivity

Windows Host Installation and Integration for Block 12

Page 13: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Viewing Block Storage PortsClick icon to add picture

Windows Host Installation and Integration for Block 13

Page 14: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Initiator Registration Records: Fibre

Number of initiators is model dependent

An initiator is an HBA or CNA port that can access the storage system• Some HBAs and CNAs have two ports• Each path consumes one initiator recordAccess from a server to an SP in a storage system can be: • Single path• Multipath• Alternate path

14Windows Host Installation and Integration for Block

Page 15: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Initiator Registration Records Format: Fibre Channel• Hostname• Host IP address• Host HBA WWNs

128 bit number - WWNN + WWPN• VNX port WWNs

128 bit number - WWNN + WWPN• Operating system type

Allows appropriate response to host SCSI commands

15Windows Host Installation and Integration for Block

Page 16: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Unisphere Host Initiators: Fibre

Windows Host Installation and Integration for Block 16

Page 17: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Initiator Information: Fibre

17Windows Host Installation and Integration for Block

Page 18: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Viewing SP Fibre Channel Port Properties

18Windows Host Installation and Integration for Block

Page 19: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Server and FCoE CNA Adapters

Windows Host Installation and Integration for Block 19

Page 20: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Initiator Registration Records: iSCSI Names• iSCSI address

Uniquely identifies nodes Two variations

iqn. – iSCSI Qualified Name (IQN) iqn.1992-04.com.emc:cx.fnm00130702376.a5 iqn.1992-04.com.emc:cx.fnm00130702376.b5

eui. – Extended Unique Identifier (EUI) eui.50060162AEA5574E

20Windows Host Installation and Integration for Block

Page 21: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Unisphere Host Initiators: iSCSIClick icon to add picture

Windows Host Installation and Integration for Block 21

Page 22: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Initiator Information: iSCSI

Windows Host Installation and Integration for Block 22

Page 23: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Viewing iSCSI Front-end Port Properties

Windows Host Installation and Integration for Block 23

Page 24: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Host Installation and Integration for Block

During this lesson the following topics were covered:• VNX Fibre Channel connections to a Windows Host• VNX FCoE connections to a Windows Host• VNX iSCSI connections to a Windows Host

Lesson 2: Summary

Windows Host Installation and Integration for Block 24

Page 25: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Host Installation and Integration for Block

This lesson covers the following topics:• Implementing Windows FC connectivity• Implementing Windows iSCSI connectivity

Lesson 3: Implementing Windows Connectivity

Windows Host Installation and Integration for Block 25

Page 26: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Connectivity Steps

Check and validate all host to VNX connectivity (FC and iSCSI)•OCManager utility (Emulex)

•SANsurfer (Qlogic)

•Unisphere Host Initiator option

•Unisphere Server Utility

Create a storage

group, add LUNs and connect

your Windows

host

Run Windows Disk Management•Rescan or reboot may be required

Initialize the disk•Write signature on disk (LUN)

Add drive letter(s)

Format the disk (LUN)

Write data to the disk

(LUN)

Windows Host Installation and Integration for Block 26

Page 27: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Host Registration

• Automatically• Manually

Registration makes a host known to the storage system

• Fabric logins tell the VNX which ports and HBAs are connected

• iSCSI logins tell the VNX which ports and initiators (hardware or software based) are connected

Connectivity depends on the protocol being used:

27Windows Host Installation and Integration for Block

Page 28: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Unisphere Host Agent• The Unisphere Host Agent tells the VNX about either the:

Hostname and HBA WWNs Hostname and Host IQN or EUI

28Windows Host Installation and Integration for Block

Page 29: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

EMC Unisphere Server Utility

29Windows Host Installation and Integration for Block

Page 30: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Creating a Storage Group

30Windows Host Installation and Integration for Block

Page 31: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Adding LUNs to a Storage Group

31Windows Host Installation and Integration for Block

Page 32: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Adding Hosts to a Storage Group

32Windows Host Installation and Integration for Block

Page 33: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows 2012 Disk Management: Online Disk

33Windows Host Installation and Integration for Block

Page 34: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Window 2012 Disk Management

34Windows Host Installation and Integration for Block

Page 35: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

Windows Host Installation and Integration for Block

During this lesson the following topics were covered:• Implementing Windows FC connectivity• Implementing Windows iSCSI connectivity

Lesson 3: Summary

Windows Host Installation and Integration for Block 35

Page 36: Windows  Host Installation and Integration for Block

Copyright © 2014 EMC Corporation. All Rights Reserved.

SummaryKey points covered in this module:• Connectivity requirements include:

Supported HBAs, HBA drivers, vendor management software, and proper cabling to the fabric switches.

Fabric switches properly configured and zoned Management station with supported OS, Web Browser, Java, and

network connectivity to the VNX.• Several configuration are key to successful host integration, such

as initiator records and port properties• Steps to implement Windows connectivity in both a Fibre

Channel and iSCSI environment