fire hydrant
Citation preview
Fire Hydrant System
We offer a range of FIRE HYDRANT SYSTEM and YARD HYDRANTS with all
required accessories. Some of the feature of these systems is as follows -
HYDRANT SYSTEM
The Hydrant System comprises of AC motor driven pump sets with all
required accessories including valves, instrumentation and controls etc.
Complete in all respects. An automatic hydrant system is furnished covering
the areas completely from independent
Pipe work from the fire water pump set.
The hydrant pipe work is remaining pressurized through the proposed jockey
pump taking care of any leakages in the system pipe lines, valves and fittings.
The hydrant system is kept charged by pressurized water at approx. 7 Kg. Cm.
Sq. at all times. In the event of fire when any of the hydrant valves in the net
work is opened,the resultant fall in pressure system is enabling starting the AC
MOTOR driven fire water pumping set through pressure switches
automatically. One diesel engine pump shall be standby pump serving hydrant
system. Apart from the automatic starting of the pump sets, provision shall be
kept for manual starting also. Shutting down of the pump sets shall be
manual.
YARD HYDRANTS
Hydrants inside the building is furnished with required accessories such as
hose pipes with instantaneous gun metal couplings and g.m branch pipes
located in hose cabinets. The hose cabinets are wall / column mounting type,
constructed out of 18 gauge mild steel sheets.
The internal hydrants (Landing valves) is single headed type taken out
from 150/100 mm dia riser through suitable reducer. The outlets are gun
metal and confirm to IS: 5290. HT Hose reels is firmly held against the wall
by suitable heavy brackets and supports. The hose reel is swinging type (180
deg.) and the entire Dum reel etc. is as per IS: 3876. The rubber tubing is best
quality (Dunlop) and the nozzle is 6 mm dia. Shut off type. The equipment
shall be out of one of the approved makes
The hydrant main is laid in the form of ring main. The hydrant risers are
terminated with air release valves at the highest points to release the trapped
air in the pipe work.
Fire Sprinkler System
Sprinkler is thermo-sensitive quarzoid liquid glassbulb burst actuated type and be
standard products from an established firm of repute and standing and approved by an
appropriate authority for fire fighting duty. It should be imported only.
All sprinklers is brass castings polished / chrome OR white (polyester) unless stated
otherwise and rated for 12.0 KG/CM2 WG and factory tested for 34.0 KG/CM2.
Sprinklers are pendant OR side wall type as specified and shown on drawings. All
sprinklers shall be provided with an adjustable OR Rosettes escutcheons finished
same as the sprinkler head.
Temp. Classification of sprinklers in each space shall be as shown on the drawings.
Sprinklers shall be selected for the coverage shown on the drawings and ordinarily be
15 MM. Wherever the specified sprinkler is not adequate. The tenders may offer
appropriate size required. Tenders are free to suggest alternatively other suitable
sprinklers with its justification.
Fire Alarm System
We offer our clients our qualitative range of fire alarm systems that is manufactured
by certified companies. These fire alarm systems work on 230V supply and have
provision for battery backup. The equipment provides relay output for interfacing
with security panel, auto-dialer, and audio alarm via siren or buzzer and have zone-
wise visual indications for open, short, test or bypass conditions.
Fire Detector
We specialize in supplying and providing services for our wide range of qualitative
fire detectors. These are procured from certified and reputed manufacturers. Our
range of fire detectors is available with following technical and general specifications:
Light test feature makes testing easy with a flashlight beam
85 dB alarm
Two 9-volt batteries included
5 year limited warranty
CCTV System
In our wide range of fire fighting equipment and accessories, we have CCTV systems
that play vital role in identifying the source of firebreak and preventing it to spread
further by alerting fire fighting personnel. Our CCTV systems are available in
following specifications:
Number of pixels PAL: 512(H)*582(V)
System of signal NTSC/PAL
Lens 16mm
Horizontal resolution 420TVL
Minimum illumination 0Lux
Backlight compensation auto
Electronic shutter 1/50(1/60) ~1/100,000sec
White balance auto
S/N ratio 48dB
Gamma correction 0.45
Operation temperature -20~50
Sync. System internal
Video output 1.0v p-p /75
Power supply DC12V, 8000mA
Dimensions (mm) 60(w)*55(h)*130(d)
Wet Riser System
We supply and provide services for high quality wet riser systems. While providing
maintenance to the Risers, we conduct an initial physical inspection to check
following components:
Valves
Pipework
Seals
Strap
Padlock
Earthing
Cabinet locks
Pressure test at inlet
Pressure test at outlet
Non return valves
Drain down system
Co2 Flooding System
Our company supplies flooding systems that are based on Co2 (Carbon Dioxide) gas.
Co2 is used in the system due to its high ratio of expansion that facilitates rapid
discharge and allows three-dimensional penetration of the entire hazard area quickly.
CO2 extinguishes a fire by reducing the oxygen content of the protected area below
the point where it can support combustion. The extreme density of CO2 assists in
permeating the protected hazard area effectively and suppresses the fire. Due to the
rapid expansion of the 4-6 inches of CO2 snow to gas, the ambient temperature is
reduced in the protected hazard area. This helps in the extinguishing process and
retards re-ignition. CO2 is electrically non-conductive and it has no residual cleanup
associated with its use as a fire-suppressing agent. The proper ventilation allows the
gas to escape to atmosphere after the fire has been extinguished.
Water Spray System
We offer our clients a wide range of water spray system that is manufactured by
reputed vendors. These systems find application in various commercial and industrial
establishments. We have several types available with us that include systems
with G.M/SS type nozzles with stainless steel clamp for quick fixing or unfixing of
nozzles. This arrangement helps in cleaning of the nozzles easily without any help of
tools. Our water spray systems have sturdy looks and are durable enough to resist the
pressure created by the water force.
Bulb Sprinkler
Sprinkler is thermo-sensitive quarzoid liquid glassbulb burst actuated type and be
standard products from an established firm of repute and standing and approved by an
appropriate authority for fire fighting duty. It should be imported only.
All sprinklers is brass castings polished / chrome OR white (polyester) unless stated
otherwise and rated for 12.0 KG/CM2 WG and factory tested for 34.0 KG/CM2.
Sprinklers is pendant OR side wall type as specified and shown on drawings. All
sprinklers shall be provided with an adjustable OR Rosettes escutcheons finished
same as the sprinkler head.
Temp. Classification of sprinklers in each space shall be as shown on the drawings.
Sprinklers shall be selected for the coverage shown on the drawings and ordinarily be
15 MM. Wherever the specified sprinkler is not adequate. The tenders may offer
appropriate size required. Tenders are free to suggest alternatively other suitable
sprinklers with its justification.
Fire Extinguisher
We offer our clients a wide range of fire extinguishers that comprise following types:
A B C" Stored pressure type: Our ABC fire extinguisher is useful for fires of
A, B and C types. Fire breaking out in these types involves cotton, wood,
grease, flammable liquids, electrical wiring, live machinery and others. The
blanketing effect of extinguishers helps in decomposing fire rapidly. Our
equipment is available in following specifications:
B.I.S. Specification: 13849
Capacity: 1Kg, 2 Kg, 5 Kg, 10 Kg, & above with ISI Mark
CO2 type fire extinguishers: We supply CO2 fire extinguishers that are used
for class B and C fires. These classes include oil spillages, fabric, delicate
machinery and various other materials. Our CO2 type extinguishers are able to
extinguish fire by blanketing dilution of oxygen and cooling effects. These are
available in following specifications:
B.I.S. Specification: 2878
Capacity: 2, 3.2, 4.5, 6.5, 9 kg. & 22.5 kg with ISI Mark
Dry chemical powder type fire extinguishers: Our trolley mounted dry
chemical powder fire extinguisher is used in controlling class B and C fires
which include fire caused due to material such as fats, gases, paints, oils,
electrical wiring, solvents, varnish, live machineries and others. These
extinguish fire by displacement of air, beating and decomposition of dry
powder effects. Our dry chemical powder type fire extinguishers are offered in
following specifications:
B.I.S. Specification: 2171 & 10658 :
Capacity: 5kg, 10 kg, 25kg,50 kg,75 kgs with ISI mark
Mechanical foam (AFFF): We supply mechanical foam fire extinguisher that
is used for class A and B fires. These classes involve fire due to various
liquids such as paints, tar, solvents, benzene camphor, naphtha, varnish and
fats like grease and oils. These also include solids such as pigments, resins and
oils. Our mechanical foam extinguisher controls fire by cutting off the
atmospheric supply of oxygen to the burning surface that is known as
blanketing process. It also cools down the container and contents. These are
available with following specifications:
B.I.S. Specification: 10204 & 13386:
Capacity: 9 liter & 50 liter with ISI mark
Hose Reel
Hose reel is important equipment used for fire fighting purposes. We supply our
comprehensive range of hose reels procured from reliable vendors. Our hose reels are
UL approved and possess following features:
Reel diameter: 550mm / 600mm
Tail: 3 / 4" or 1"
Hose length: 20m / 25m / 30m
Hydrant Valves
We offer our clients 63mm Single outlet Landing Valve as per IS: 5290 Type A
specifications. These ISI marked hydrant valves are available in 75mm NB inlet &
63mm female inst. outlet. These are manufactured by using Gunmetal of IS 318
LTB2/ SS304/ SS316 specifications. Its inlet can be provided in flanged type as per
our clients requirement. The outlet is generally female instantaneous and male inst.
outlet is available on request. Our hydrant valves are available in size range of 38mm
to 63mm.