9
Fire Hydrant System We offer a range of FIRE HYDRANT SYSTEM and YARD HYDRANTS with all required accessories. Some of the feature of these systems is as follows - HYDRANT SYSTEM The Hydrant System comprises of AC motor driven pump sets with all required accessories including valves, instrumentation and controls etc. Complete in all respects. An automatic hydrant system is furnished covering the areas completely from independent Pipe work from the fire water pump set. The hydrant pipe work is remaining pressurized through the proposed jockey pump taking care of any leakages in the system pipe lines, valves and fittings. The hydrant system is kept charged by pressurized water at approx. 7 Kg. Cm. Sq. at all times. In the event of fire when any of the hydrant valves in the net work is opened,the resultant fall in pressure system is enabling starting the AC MOTOR driven fire water pumping set through pressure switches automatically. One diesel engine pump shall be standby pump serving hydrant system. Apart from the automatic starting of the pump sets, provision shall be kept for manual starting also. Shutting down of the pump sets shall be manual. YARD HYDRANTS Hydrants inside the building is furnished with required accessories such as hose pipes with instantaneous gun metal couplings and g.m branch pipes located in hose cabinets. The hose cabinets are wall / column mounting type, constructed out of 18 gauge mild steel sheets. The internal hydrants (Landing valves) is single headed type taken out from 150/100 mm dia riser through suitable reducer. The outlets are gun metal and confirm to IS: 5290. HT Hose reels is firmly held against the wall by suitable heavy brackets and supports. The hose reel is swinging type (180 deg.) and the entire Dum reel etc. is as per IS: 3876. The rubber tubing is best quality (Dunlop) and the nozzle is 6 mm dia. Shut off type. The equipment shall be out of one of the approved makes The hydrant main is laid in the form of ring main. The hydrant risers are terminated with air release valves at the highest points to release the trapped air in the pipe work.

Windows-1256__Úáã ÃßÇÝÍÉ ÇáÍÑíÞ ÈÅÎÊÕÇÑ

  • Upload
    indraw

  • View
    212

  • Download
    0

Embed Size (px)

DESCRIPTION

fire hydrant

Citation preview

  • Fire Hydrant System

    We offer a range of FIRE HYDRANT SYSTEM and YARD HYDRANTS with all

    required accessories. Some of the feature of these systems is as follows -

    HYDRANT SYSTEM

    The Hydrant System comprises of AC motor driven pump sets with all

    required accessories including valves, instrumentation and controls etc.

    Complete in all respects. An automatic hydrant system is furnished covering

    the areas completely from independent

    Pipe work from the fire water pump set.

    The hydrant pipe work is remaining pressurized through the proposed jockey

    pump taking care of any leakages in the system pipe lines, valves and fittings.

    The hydrant system is kept charged by pressurized water at approx. 7 Kg. Cm.

    Sq. at all times. In the event of fire when any of the hydrant valves in the net

    work is opened,the resultant fall in pressure system is enabling starting the AC

    MOTOR driven fire water pumping set through pressure switches

    automatically. One diesel engine pump shall be standby pump serving hydrant

    system. Apart from the automatic starting of the pump sets, provision shall be

    kept for manual starting also. Shutting down of the pump sets shall be

    manual.

    YARD HYDRANTS

    Hydrants inside the building is furnished with required accessories such as

    hose pipes with instantaneous gun metal couplings and g.m branch pipes

    located in hose cabinets. The hose cabinets are wall / column mounting type,

    constructed out of 18 gauge mild steel sheets.

    The internal hydrants (Landing valves) is single headed type taken out

    from 150/100 mm dia riser through suitable reducer. The outlets are gun

    metal and confirm to IS: 5290. HT Hose reels is firmly held against the wall

    by suitable heavy brackets and supports. The hose reel is swinging type (180

    deg.) and the entire Dum reel etc. is as per IS: 3876. The rubber tubing is best

    quality (Dunlop) and the nozzle is 6 mm dia. Shut off type. The equipment

    shall be out of one of the approved makes

    The hydrant main is laid in the form of ring main. The hydrant risers are

    terminated with air release valves at the highest points to release the trapped

    air in the pipe work.

  • Fire Sprinkler System

    Sprinkler is thermo-sensitive quarzoid liquid glassbulb burst actuated type and be

    standard products from an established firm of repute and standing and approved by an

    appropriate authority for fire fighting duty. It should be imported only.

    All sprinklers is brass castings polished / chrome OR white (polyester) unless stated

    otherwise and rated for 12.0 KG/CM2 WG and factory tested for 34.0 KG/CM2.

    Sprinklers are pendant OR side wall type as specified and shown on drawings. All

    sprinklers shall be provided with an adjustable OR Rosettes escutcheons finished

    same as the sprinkler head.

    Temp. Classification of sprinklers in each space shall be as shown on the drawings.

    Sprinklers shall be selected for the coverage shown on the drawings and ordinarily be

    15 MM. Wherever the specified sprinkler is not adequate. The tenders may offer

    appropriate size required. Tenders are free to suggest alternatively other suitable

    sprinklers with its justification.

    Fire Alarm System

  • We offer our clients our qualitative range of fire alarm systems that is manufactured

    by certified companies. These fire alarm systems work on 230V supply and have

    provision for battery backup. The equipment provides relay output for interfacing

    with security panel, auto-dialer, and audio alarm via siren or buzzer and have zone-

    wise visual indications for open, short, test or bypass conditions.

    Fire Detector

    We specialize in supplying and providing services for our wide range of qualitative

    fire detectors. These are procured from certified and reputed manufacturers. Our

    range of fire detectors is available with following technical and general specifications:

    Light test feature makes testing easy with a flashlight beam

    85 dB alarm

    Two 9-volt batteries included

    5 year limited warranty

    CCTV System

  • In our wide range of fire fighting equipment and accessories, we have CCTV systems

    that play vital role in identifying the source of firebreak and preventing it to spread

    further by alerting fire fighting personnel. Our CCTV systems are available in

    following specifications:

    Number of pixels PAL: 512(H)*582(V)

    System of signal NTSC/PAL

    Lens 16mm

    Horizontal resolution 420TVL

    Minimum illumination 0Lux

    Backlight compensation auto

    Electronic shutter 1/50(1/60) ~1/100,000sec

    White balance auto

    S/N ratio 48dB

    Gamma correction 0.45

    Operation temperature -20~50

    Sync. System internal

    Video output 1.0v p-p /75

    Power supply DC12V, 8000mA

    Dimensions (mm) 60(w)*55(h)*130(d)

    Wet Riser System

    We supply and provide services for high quality wet riser systems. While providing

    maintenance to the Risers, we conduct an initial physical inspection to check

    following components:

    Valves

    Pipework

    Seals

    Strap

    Padlock

    Earthing

    Cabinet locks

  • Pressure test at inlet

    Pressure test at outlet

    Non return valves

    Drain down system

    Co2 Flooding System

    Our company supplies flooding systems that are based on Co2 (Carbon Dioxide) gas.

    Co2 is used in the system due to its high ratio of expansion that facilitates rapid

    discharge and allows three-dimensional penetration of the entire hazard area quickly.

    CO2 extinguishes a fire by reducing the oxygen content of the protected area below

    the point where it can support combustion. The extreme density of CO2 assists in

    permeating the protected hazard area effectively and suppresses the fire. Due to the

    rapid expansion of the 4-6 inches of CO2 snow to gas, the ambient temperature is

    reduced in the protected hazard area. This helps in the extinguishing process and

    retards re-ignition. CO2 is electrically non-conductive and it has no residual cleanup

    associated with its use as a fire-suppressing agent. The proper ventilation allows the

    gas to escape to atmosphere after the fire has been extinguished.

  • Water Spray System

    We offer our clients a wide range of water spray system that is manufactured by

    reputed vendors. These systems find application in various commercial and industrial

    establishments. We have several types available with us that include systems

    with G.M/SS type nozzles with stainless steel clamp for quick fixing or unfixing of

    nozzles. This arrangement helps in cleaning of the nozzles easily without any help of

    tools. Our water spray systems have sturdy looks and are durable enough to resist the

    pressure created by the water force.

    Bulb Sprinkler

    Sprinkler is thermo-sensitive quarzoid liquid glassbulb burst actuated type and be

    standard products from an established firm of repute and standing and approved by an

    appropriate authority for fire fighting duty. It should be imported only.

    All sprinklers is brass castings polished / chrome OR white (polyester) unless stated

    otherwise and rated for 12.0 KG/CM2 WG and factory tested for 34.0 KG/CM2.

    Sprinklers is pendant OR side wall type as specified and shown on drawings. All

    sprinklers shall be provided with an adjustable OR Rosettes escutcheons finished

    same as the sprinkler head.

    Temp. Classification of sprinklers in each space shall be as shown on the drawings.

    Sprinklers shall be selected for the coverage shown on the drawings and ordinarily be

    15 MM. Wherever the specified sprinkler is not adequate. The tenders may offer

    appropriate size required. Tenders are free to suggest alternatively other suitable

    sprinklers with its justification.

  • Fire Extinguisher

    We offer our clients a wide range of fire extinguishers that comprise following types:

    A B C" Stored pressure type: Our ABC fire extinguisher is useful for fires of

    A, B and C types. Fire breaking out in these types involves cotton, wood,

    grease, flammable liquids, electrical wiring, live machinery and others. The

    blanketing effect of extinguishers helps in decomposing fire rapidly. Our

    equipment is available in following specifications:

    B.I.S. Specification: 13849

    Capacity: 1Kg, 2 Kg, 5 Kg, 10 Kg, & above with ISI Mark

    CO2 type fire extinguishers: We supply CO2 fire extinguishers that are used

    for class B and C fires. These classes include oil spillages, fabric, delicate

    machinery and various other materials. Our CO2 type extinguishers are able to

    extinguish fire by blanketing dilution of oxygen and cooling effects. These are

    available in following specifications:

    B.I.S. Specification: 2878

    Capacity: 2, 3.2, 4.5, 6.5, 9 kg. & 22.5 kg with ISI Mark

    Dry chemical powder type fire extinguishers: Our trolley mounted dry

    chemical powder fire extinguisher is used in controlling class B and C fires

    which include fire caused due to material such as fats, gases, paints, oils,

    electrical wiring, solvents, varnish, live machineries and others. These

    extinguish fire by displacement of air, beating and decomposition of dry

    powder effects. Our dry chemical powder type fire extinguishers are offered in

    following specifications:

    B.I.S. Specification: 2171 & 10658 :

    Capacity: 5kg, 10 kg, 25kg,50 kg,75 kgs with ISI mark

    Mechanical foam (AFFF): We supply mechanical foam fire extinguisher that

    is used for class A and B fires. These classes involve fire due to various

  • liquids such as paints, tar, solvents, benzene camphor, naphtha, varnish and

    fats like grease and oils. These also include solids such as pigments, resins and

    oils. Our mechanical foam extinguisher controls fire by cutting off the

    atmospheric supply of oxygen to the burning surface that is known as

    blanketing process. It also cools down the container and contents. These are

    available with following specifications:

    B.I.S. Specification: 10204 & 13386:

    Capacity: 9 liter & 50 liter with ISI mark

    Hose Reel

    Hose reel is important equipment used for fire fighting purposes. We supply our

    comprehensive range of hose reels procured from reliable vendors. Our hose reels are

    UL approved and possess following features:

    Reel diameter: 550mm / 600mm

    Tail: 3 / 4" or 1"

    Hose length: 20m / 25m / 30m

  • Hydrant Valves

    We offer our clients 63mm Single outlet Landing Valve as per IS: 5290 Type A

    specifications. These ISI marked hydrant valves are available in 75mm NB inlet &

    63mm female inst. outlet. These are manufactured by using Gunmetal of IS 318

    LTB2/ SS304/ SS316 specifications. Its inlet can be provided in flanged type as per

    our clients requirement. The outlet is generally female instantaneous and male inst.

    outlet is available on request. Our hydrant valves are available in size range of 38mm

    to 63mm.