15
White Paper: Hazardous area classification and overview of Arista Industrial computers Abstract This technical white paper addresses primary specifications and classification of hazardous area classifications/hazardous locations safety issues, industry regulations and security standards across the globe. This white paper will also give insight on class 1 division 2 and zone system for protection. Particularly for chemical, petrochemical and other similar industries where an explosion protected equipment is a necessity. With a focus on maintaining a completely safe industrial environment this paper will give provide information on Arista specialized range of non-incendive, corrosion resistant and HMI embedded system with thin clients industrial panel PCs, touch panel PCs, UL class 1 division 2 certified specialized for work in food processing, cold storage, pharmaceuticals and other harsh industrial environment. Arista Corporation All Rights Reserved

White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

  • Upload
    others

  • View
    16

  • Download
    1

Embed Size (px)

Citation preview

Page 1: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

White Paper: Hazardous area classification and overview of Arista Industrial computers

Abstract

This technical white paper addresses primary specifications and classification of hazardous area classifications/hazardous locations safety issues, industry regulations and security standards across the globe. This white paper will also give insight on class 1 division 2 and zone system for protection. Particularly for chemical, petrochemical and other similar industries where an explosion protected equipment is a necessity.

With a focus on maintaining a completely safe industrial environment this paper will give provide information on Arista specialized range of non-incendive, corrosion resistant and HMI embedded system with thin clients industrial panel PCs, touch panel PCs, UL class 1 division 2 certified specialized for work in food processing, cold storage, pharmaceuticals and other harsh industrial environment.

Arista Corporation All Rights Reserved

Page 2: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com

Hazardous area classification in a nutshell and overview of Arista Industrial computers

Table of Contents Introduction .......................................................................................................................................................................... 2

What is an explosion? ........................................................................................................................................................ 3

Design Regulations for anti-explosion electrical industrial automation equipments. ............................. 4

Non-Incendive standard defined for Electrical equipment ................................................................................ 5

Hazardous zone and their classification .................................................................................................................... 5

Class Definition: North America Classification System ........................................................................................ 5

Zone System Classification .............................................................................................................................................. 7

Temperature Class defination and explanation: ..................................................................................................... 9

Differentiating Class/Division system with their Zone system...................................................................... 10

Sources of Ignition ........................................................................................................................................................... 11

Installing and operating equipments in hazardous locations......................................................................... 12

Protection techniques:Hazardous Area ................................................................................................................... 12

Overview of Arista Class 1 Div 2 Hazardous Zone Industrial computers .................................................. 13

Disclaimer ........................................................................................................................................................................... 15

Introduction The complexity of today’s industrial automation needs, demands a safe and secure working environment. Manufactures and end users require more extensive effort to invest and comply with security regulations to avoid any unexpected fire or explosion hazard. Specifically when it comes to hazardous area classified locations. Electrical equipments in the industrial area are prone to cause explosions under certain atmospheric conditions.

Understanding the tough industrial needs Arista talented team of engineers focuses on the safety essentials and comply with electrical equipment regulations according to hazardous classified locations and different country’s standard. Arista works hard over every certifications and testing centre for the design and manufacturing of equipment

Page 3: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com

What is an explosion? An Explosion is a sudden expansion involving physical or chemical decay with a rapid increase in pressure, resulting in a heavy blast and shock. In a chemical explosion molecule decomposes into combustible gases produced at a very high temperature. For an explosion to take place three factors which are flammable materials, air (oxygen) and ignition sources has to be present in sufficient quantities in the atmosphere.

Refer to figure1 below:

Figure 1

An explosion does not occur only in the presence of flammable materials, there should be sufficient quantity of such materials present for any hazard to occur. However, there are plenty of classifications and requirements that fall under hazardous zone and their level of severity. Country Specific regulating bodies set up standards for safety, explosion protection and level of severity.

EXPLOSION

Flammable materials

Oxygen (Air )

Sources of Ignition

There are several ways of protecting electrical equipment hazard, to avoid explosion when used in flammable materials, combustible and fibers.

Page 4: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com Find detailed information below:

Country/Region Standard & Marking

Description

North America

For North America hazardous locations, equipment certification are performed by nationally recognized laboratories UL, MET, FM and CSA. In addition, the American National Standard Institute coordinates US standard to be used internationally and allow equipment to be used globally.

Europe

This standard is in accordance with EU directives; EN 60079 and 61241 specifically cover explosion protection. The CE along with Ex mark follows indications of the group and category. Also, if Group II equipment relates to the gases (G) or dust (D)

International

This standard addresses “Hazardous Locations”, “Hazardous Area”, and “Explosive Atmosphere”. Places where flammable liquids, vapors, gases or combustible dusts along with sufficient quantities to cause fire or explosion.

Design Regulations for anti-explosion electrical industrial automation equipments. Regulations are specifically meant for equipment to be used in hazardous locations defined by law. However, these might vary according to the location, country laws and other factors. Equipment not pertaining to regulations can counter delay in their shipping and face legal and liability issues.

Regulations for Class/Division system are formulated by NEC, CEC, OSHA and NFPA (National Fire Protection Association).It is mandatory for every manufacturer to adhere by compliance, these are monitored by UL and other testing groups as mentioned above. After equipment pass test they are provided with a certificate stating; “explosion protection safety conditions are met and they are secured to be used for production”.

Page 5: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com

Non-Incendive standard defined for Electrical equipment International Society of Automation (ISA) and the American National Standard Institute (ANSI) have defined the non-incendive standard for electrical equipments to be used in hazardous locations. These standards provide design, construction and electrical marking requirements to be used in Class I and Class II, and Class III, Division 1 and 2 hazardous locations. Hazardous zone and their classification In simple terms, hazardous classified location is any area, building, commercial or industrial premises which are likely to be exposed to fire or explosion due to the presence of flammable gases, vapors, flammable liquids, combustible dusts and other similar things in the very high amount. Hazardous locations can be classified into various categories according to the nature of flammable vapors or liquids. These categories can be defined by classes and classified by NFPA Publication 70, NEC and CEC. Below are the classification of locations and division, which define the type of explosive or ignitable substance present in the atmosphere.

Class Definition: North America Classification System In the United States and North America, manufacturer’s in general follow standards set up by National Electric Code (NEC). Other popular classifications are NFPA publication and CEC. These benchmarks along with NEC specify type of hazardous materials based on class, division and groups.

Class/Division standards are the primary methods catering the design and manufacturing of industrial equipments across North America. The in-depth classification is widespread but it addresses all aspects of explosion protection and safety measures best practices. All these classes are categorized as per different explosives or ignitable substances that are found in the Atmosphere. The intent of this paper is to focus primarily on Class I division 2 locations and its further classification.

North America Hazardous classified location, Zone Classification

Class I

Location consisting of flammable gases or vapors in an amount to create a hazard.

Division 2

Locations with fewer chances of hazard but can exist with due to unwanted interference.

Page 6: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com Refer to the brief explanation and description below for the North America Classification system.

Class Area Division Group Temperature Class

Hazardous materials categories are classified by NFPA Publication 70, NEC and CEC. The three classes define the type of explosive or ignitable material present in the atmosphere. Class I: Locations where flammable gases or vapors are found. Class II: Locations where combustible dust, which can be involved in an event of ignition. Class III: Locations with presence of frequent ignitable fibers or flyers.

It defines the possibility of hazardous materials to be present and use of appropriate equipment with safe installation practices.

The classes mentioned are further classified into Division I and Division II.

• Division 1 Ignitable concentrations of flammable gases or vapors, they might exist because of frequent repair, maintenance, operations or any sort of leakage. Also breakdown and equipment with fault or failure are in this division.

• Division 2 Volatile flammable liquids or gases stored in containers or closed system, but are exposed in any sort of accident, breakdown or abnormal operation of equipment.

Division I and II are further classified into groups of hazardous material with varying gases, vapors or dusts in the air. The groups are defined of flammable materials rating with respect to other materials.

It is the maximum temperature meant for equipment operating on the surface of equipment and should not go beyond the ignition temperature of the nearby atmosphere.

Page 7: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com Zone System Classification As discussed above Class/Division system are specifically used in North America for the purpose of regulating and defining hazardous locations for equipment safe handling and installation. However, outside of North America, the zone system is being used as a primary source equipment in manufacturing and installation. Zone system is quite similar to class/division system; it defines and categorizes hazardous area and potential risk sources.

Refer figure 2 for a detailed classification.

Figure 2

Likewise, there are other zones that cover potential flammable dust hazard, refer to the table below:

Zone 20 Zone 21 Zone 22 Frequent or large presence of flammable dust

Occasional or less presence of flammable dust

Very less chances for presence of flammable dust.

Zone

0 Concentration of

flammable gases or vapors for long periods must be present for an area to be considered class 1 zone 0

Zone

1 Concentrations of

flammable gases or vapors under normal conditions ,they might be present due to repair, maintenance or leakage or there is any fault in equipment it qualifies for class 1 zone 1 location

Zone

2 1.Volatile flammable

liquids, gases or vapors handled,processed or used but can escape,rupture or breakdown of containers. 2.Ignitable concentrations of flammable gases or vapors prevented by positive ventilation but can become hazardous due to failure or abnormal ventilation. 3.Location next to Class 1 Zone 1 where concentrations of flammable material can communicate falls in zone 2

Page 8: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com To get a clearer picture, frequency of occurrence of an event determines the hazard level of that location. Hence, the more flammable materials are present in atmosphere the more are chances for an explosion to occur.

Refer to the table below:

Frequency Zone Constant, rare or occasionally Zone 0 and 1

Irregular condition Zone 2

In addition, it is important to understand how the flammable substances/materials are categorized and how to get a better understanding of each of them.

Refer to figure 3 below:

Figure 3

Note: Ignition or explosion can only occur when flammable gas,liquid or solid material have their lower and upper flammability limits. Hence,not necessarily the presence of flammable material will result in a fire hazard.

Flammable substance Gas

Flammable gas are compounds of hydrogen and carbon which are

highly flammable even with little reaction possibility.

Example: Hydrogen, acetylene, ammonia etc.

Liquids/Vapors Flammable liquids and vapors when

present in sufficient quantities at room temperature can turn into potential explosion hazard.Flash point of flammable liquid is the

lowest temperature at which vapors can arise and ignite.

Example:Hydrocarbons

Solids Unlike gas and liquids, for solid

flammable materials, a dust cloud can settle if it is not ignited.If

removal and cleaning of layers is not done, dust can build up resulting in explosion.Initially on a smaller level

but can result in seroius bigger explosions.

Example:Dust fibres

Page 9: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com

Temperature Class defination and explanation: Equipment used in hazardous area is assigned to a temperature class which defines maximum surface temperature the device can go. This temperature should not exceed the ignition temperature of the atmosphere. With minimum presence of ignition temperature, during the normal atmospheric pressure without spark or flame is able to set fire or a combustion or independent heating of the element. The dedicated rating for a temperature class also helps in preventing combustion that is dependent on the combustion point of the material present in that area.

Temperature classification are given to hazardous areas and temperature class ratings are applied to instruments.Values for the temerature classificaion ranges from T1 to T6,where T1 implies a minimum ignition temperature (>450° C [842° F) and T6 has a minimum ignition temperature >85° C [185° F].

Temperature class rating, this relates to the maximum temperature instrument is supposed to produce typically at a 40°C environmental temperature. However, this might vary in reference to other ratings.T1 thru T6 are used in temperature class ratings, where T1 is maximum temperature generated by instrument at 40° C is 450° C and T6 is the maximum generated by the instrument is 85° C.

Refer to table below for a detailed view:

Temperature classification/Rating

Min Ignition Temperature/Area

Max instrument temperature/Equipment

T1 >450 °C, 842 °F 450 °C, 842 °F

T2 >300 °C, 572 °F 300 °C, 572 °F

T3 >200°C, 392 °F 200°C, 392 °F

T4 >135 °C, 275 °F 135 °C, 275 °F

T5 >100 °C, 212 °F 100 °C, 212 °F

T6 >85 °C, 185 °F 85 °C, 185 °F

Page 10: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com Differentiating Class/Division system with their Zone system

Page 11: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com Sources of Ignition

It is also important to know what sources can initiate a hazard,below is the list.Table A provide a general source of ignition while table B shows ignition sources from industrial electrical equipments.

Table A

Sources Example

Open flame Electric powered devices

Match, lighter,cigarette or similar products. Heater,eletric blanket or any other similar equipment.

Fuel-gas equipments Gas fire,heating device etc

Hot objects Spark,hot pipes etc

Chemical Reaction Very rare

Exposure to heat from external source like a fire nearby.

Unknown or spontaneous heating

Usually happens due to leakage,oil soaked rugs etc.

Radio Frequency (range 1&2)

Ultrasonic

Lightening

Page 12: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com

Table B

Sources Example Electrical Spark Takes place when circuits are broken,or

there is often breakage in the circuits.

Hot surface Hot surface ignition takes place due to the heat provided by coils,lamps,resistors or hot bearings.Hence,resulting is sudden fire.

Friction Usually happens due to a strike between case or enclosure.

Installing and operating equipments in hazardous locations The mission of every manufaturer,industry owner, and installer is to adhere to the regulations and standards for maximum security in their facility. Specifically for hazardous locations following safety guidlines is a must, it helps in avoiding any kind of danger and potential hazard instances.

Refer to the figure 4 below:

Figure 4

Protection techniques:Hazardous Area Hazardous area can be defined as any industrial space with presence of three fundamental components: flammable substance, oxidizer and source of flame/ignition. Hence such areas

Plant Owner

• Responsible for safe operations,monitoring and maintanence of HMI document.

Installing Authority

• Responsible for selecting and installing approvedHMI equipments.

Equipment Manufacturer

• Design and develop equipments to used in Hazardous Locations.

Page 13: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com require specialized equipment to prevent and avoid explosion. This might sound as a straightforward process but it isn’t, these are guided by regulations, guidelines and laws which are already discussed above in this paper.

The National Electrical Code (NEC), National Fire Protection Association, OSHA has set up benchmarks for hazardous area explosion protection. North America region Factory Manual (FM) and Underwriters Laboratories (UL); and Canadian Standard Association (CSA) for Canada are the certifying agencies, recently the two of them are working together on implementing programs to be made valid in both countries.

Electrical equipment to be used in hazardous area should be installed with one or more protection techniques for proper and secure operations.

As mentioned earlier, there are several methods by which equipment can be made flame and explosion proof, limiting energy and other sources.

Refer to the figure below for a detailed explanation.

Protection Method Explanation Explosion proof equipment To meet the criteria for explosion proof rating,

the enclosure should be able to prevent explosion, extinguish flames internally so that external ignition are prevented.

Dust-ignition proof equipment It will exclude dust; prevent sparks and ignition in exterior dust on the enclosure.

Hermetically sealed Equipment Equipment is sealed against the external atmosphere to prevent entry of hazardous gases or vapors.

Intrinsic safety or non-incendive Equipment electric circuits are designed in a way not to release sufficient energy for an ignition to occur. Non incendive circuits and components prevent any kind of arc or thermal effect.

Purged and pressurized system Equipment with internal circuits under pressure and ejects any sort of combustible gas and dust.

Overview of Arista Class 1 Division 2 Hazardous Zone Industrial computers Arista offers a wide range of Non-Incendive fully sealed packed application for hazardous zone. The range is Class 1 Division 2 certified and is completely safe to be used in an environment with the presence of flammable gases, vapors or combustible dust. Arista is proud to deliver best HMI

Page 14: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com embedded systems with strong monitors and integrated display. Also the range includes industrial panel PCs, industrial thin clients and multi touch projected capacitive touch.

The HMI enabled systems, monitors and displays for hazardous area are constructed with completely sealed, stainless steel enclosure, NEMA 4/4X enclosure with environmental rating UL 50 on the entire monitor and fully sealed I/O parts. The Hazardous area monitor supports temperatures from -20 to 50C, industrial grade with high quality display and resolution. In addition LCD display computers are completely sealed, water-resistant and rugged; performs completely well in the presence of dust, water, wash downs or disinfectants. The range is ideal for food processing, cold storage, pharmaceutical and any other harsh industrial environment.

Arista ARP-2200AP range

Features of ARP-2200AP:

• UL Listed safety standards, non incendive industrial panel PC for use in Class 1 Division 2 Groups A, B, C, D Hazardous classified locations.

• Sealed with stainless steel enclosure(4/4x ip 65/66 and NEMA 4/4x) • Industrial-grade, high bright LCD flat touch screens panels. • The HMI application meets Class I Division 2 hazardous locations (North America

Classification).

About Us:

Arista is a pioneer in the industry of product development, engineering, manufacturing and customer support. Originally formed in 1994, Arista has offices in China, India and Taiwan. With years of experience and expertise in Industrial Panel PCs, Industrial Monitors, Box PCs and Fanless Embedded computers, Rack Mount Computers, ACP ThinManager Ready Thin Clients, embedded CPU Boards and video Extender/Switches. Arista has served customers with reliability, Integrity and Trust. Find out more here.

Page 15: White Paper: Hazardous area classification and overview of … · 2019-08-26 · Hazardous zone and their classification In simple terms, hazardous classified location is any area,

Arista Corporation Technical White Paper www.goarista.com

Disclaimer

This paper provides only an overview of hazardous area and zone classification for equipment safety. It should not be considered as a substitute for safety guidelines and regulations. It is also recommended to consult an official legal advisory or other concerned authority in your organization for latest and updated safety regulations.