NOW STOCKING LIGHTNING PROTECTION
Air Terminals & Adaptors
Connectors, Clamps, Plates & Lugs
Bonding & Grounding Accessories (CADWELD)
Downconductors & Cable Fasteners
Through Roof, Through Wall & Cable Protectors
Surge Protection (CRITEC)
Where do you turn for lightning protection expertise and certification?
Lightning Protection Software Design ACAD Drawings Lightning Protection Training Seminars
Installation CertificationERICO will complete a takeoff of all lightningprotection products and will provide a designand a bill of material. Once the installation is complete, ERICO will coordinate with UL orLPI to obtain a 3rd Party Certification.What we need from you: Roof Plan Exterior Elevations Specifications
:
Tools • Anchoring • Fastening & Hanging Systems • Accessories • Concrete ProductsElectrical • Lighting • Voice & Data • Industrial • Automation • Utility & Lineman’s Gear • Safety
As your work site’s best friend, we support you with expansive tool lines and in-stock solutions, ready for delivery or pick-up at one of our seven convenient locations.
Tool RepairLighting Design
Distribution EquipmentTraining Classes
Specialty FasteningJob Management
your first, last and only source is right around the corner
St. Charles County
88 North Central DriveO’Fallon, MO 63366
Phone: 636-379-2850Fax: 696-379-2871
Branch Manager: Jim [email protected]
N Ce
ntra
l Dr
Elai
ne D
rW Terra Ln
Brya
n Rd
70
St. Louis County
2429 Schuetz RoadMaryland Heights, MO 63043
Phone: 314-567-4004Fax: 314-997-5776
Dorsett Rd
Schu
etz R
d
Page Ave
270
2720 Walnut PlaceSt. Louis, MO 63103
Phone: 314-535-5070Fax: 314-535-5289
Branch Manager: Al [email protected]
St. Louis City
Market St
Walnut Pl
Clark Ave S Je
ffers
on A
ve
64 40
Mid-Missouri
1711 Paris RoadColumbia, MO 65201
Phone: 573-875-4151Fax: 573-875-4240
Branch Manager: Joe [email protected]
Business Loop 70 E
Paris
Rd
Monroe St
Old
Rt 6
3
Ammonette St
70
Madison County, IL
#2 Business Center CourtCollinsville, IL 62234
Phone: 618-345-7255Fax: 618-345-2584
Branch Manager: Dirk Baecht
Horseshoe Lake Rd
N Bl
uff R
d
Business Center Ct
70
55
157
St. Clair County, IL
20 Commerce LaneLebanon, IL 62254
Phone: 618-206-1900Fax: 618-206-1903
Comm
erce Ln
15864
50
50
Mid-MO Tool, Fastening & Safety
1809 Santa Fe PlaceColumbia, MO 65202
Phone: 573-886-9777Fax: 573-886-0790
Sant
a Fe
Pl
70
Vandiver DrRang
elin
e St
ERICORe: 22 Plex Office
Job No: GA-132991Date: 3/27/2013
PRELIMINARYLIGHTNING PROTECTION ITEMIZED QUOTE
Qty. Part No. Price Total
1100 LPA100250 0.87$ 957.00$ 50 LPA141250 0.61$ 30.45$
150 LPC120250 2.30$ 345.00$ 330 LPA810 0.49$ 161.70$ 120 LPA805 0.36$ 43.22$
LPP899120 A927P023 0.30$ 36.04$
36 LPA222ST 3.76$ 135.49$ 36 LPA30212 8.40$ 302.40$
20 LPA505 1.58$ 31.50$ 4 LPA501 4.00$ 16.00$ 6 LPC502A 6.50$ 39.00$
LPC505 5.62$ LPC501 2.53$
2 LPC517 14.00$ 28.00$
6 LPA556 #VALUE!6 A927F179 0.32$ 1.94$ 6 A928K011 0.04$ 0.24$
LPA540 6.27$
LPA580 13.41$ LPA5962 21.00$ LPA5963 24.15$ LPA5964 27.30$ LPA5966 38.00$ LPA588 31.00$ LPA590 35.70$ LPC580 20.47$ LPC5962 26.45$ LPC5963 29.56$ LPC5964 36.57$ LPA5966 38.00$ LPC588 65.52$ LPC590 73.71$
6 615800 20.45$ 122.70$ 1 GTC168C 121.74$ 121.74$ 1 115PLUSF20 10.64$ 10.64$ 1 GYE162Q 340.94$ 340.94$ 1 150PLUSF20 13.32$ 13.32$ 1 PLUSCU 174.78$ 174.78$ 1 EGRD58 246.07$ 246.07$ 1 T403 21.80$ 21.80$ 1 T396 53.30$ 53.30$ List Price for Materials Only #VALUE!
CADWELD Mold SealerTool Box (included in Complete Tool Kit T315A)
MOLD,CABLE TO GRD ROD,VERT TEE HORZ THRUCADWELD® PLUS Grounding Welding Material - Type F20MOLD,CABLE TO GRD ROD,VERT X HORZ THRU CADWELD PLUS Grounding Welding Material - Type F20
Pipe Bonds
Grounding
5 foot Driver Rod Driver with insert for 5/8" Ground Rods
Pipe Bond, Cu, 8.625" - 10.750" O.DPipe Bond, Cu, 6.625" - 8.625" O.DPipe Bond, Alum, 4.5" - 6.5" O.D
IMPROVED DESIGN - CADWELD® PLUS Control Unit
5/8" X10' Copper Bonded Ground Rod 10 Mil
NUT,HEX,1/4-20,18-8SSTL
Cable and Fasteners
Air Terminals and Bases
Splicers
Bonds
Splice, Bimetallic, Parallel, 1-1/2" Contact
Splicer, Alum, Parallel Crimp, CableSplice, Alum, Tee Crimp, Cable
Pipe Bond, Alum, 8.625" - 10.750" O.DPipe Bond, Alum, 6.625" - 8.625" O.DPipe Bond, Alum, 4.5" - 6.5" O.DPipe Bond, Alum, 4" - 4.5" O.D
Pipe Bond, Cu, 4" - 4-1/2" O.DPipe Bond, Cu, 2-3/4" - 3-5/8" O.DPipe Bond, Cu, 2" - 2-3/4" O.DPipe Bond, Cu, 0.75" - 1.315 O.D
Cable, Smoothweave, Alum, 24 x 14 Gauge
Pipe Bond, Alum, 2.75" - 3.625" O.DPipe Bond, Alum, 2" - 2.75" O.D
Splicer, Cu, Parallel Crimp, Cable
Pipe Bond, Alum, 0.75" - 1.315" O.D
Bonding Plate, Alum, 8" sq Contact
Splicer, Cu, Tee Crimp, CableSplicer, Cu, Parallel, 2" Contact
BOLT,HEX HEAD,1/4-20 X 3/
Air Term, Al. 1/2" x 12" Safety TippedBase, Al., 1/2", Universal Mount
Description
SCREW,SHEET METAL,#10X5/8
Al. 5/8" Cable Strap, One HoleAl. Stamped Adhesive Cable HolderCable, Smoothweave, Cu, 29 x 17 GaugeSoft Solid Round, Alum, 4 AWG
Note: Installer shall be responsible for verifying all products and quantities prior to placing order to ensure a complete lightning protection system as requiredfor code compliance.
Size and quantity of required pipe bonds, associated cable, and splicers shall be determined by others.
1
2
3
456
7
891011
12
13
Compliance to NEC 250-46. Contractor is responsible for maintaining a 6'-0" distance from lightning protection system conductor to all conductive metal components.Lightning protection materials for any other buildings, additions, and structures, new or existing.
Bonding of interior or exterior doors, windows, and louvers.Bonding of interior or exterior electrical or mechanical equipment, etc.Grounding resistance tests and ground rod test wells.Labor estimates and materials for cutting and patching paved or landscaped areas for process of installing lightning protection system grounding.
1" PVC conduit, fastened and installed as raceway for routing exposed or concealed downlead cables.Trenching and backfilling for below grade routing of counterpoise ground loop cable at 18" minimum depth.Bond to underground metal piping systems entering buildings as required by UL, NFPA, and LPI standards on water, gas, storm, sanitary, conduit, and other such pipes.Special systems grounding of electrical system bonds to building steel, signal reference grounds, bus bars, electrical service entrance grounding, transformer grounding, telephone system grounding, etc.
Unless otherwise specified above, the following items ARE NOT INCLUDED in the lot materials price but are necessary to provide a complete lightning protection system per standards and specifications.
Surge protectors, required on certified lightning protection systems per UL, NFPA, and LPI standards on electrical, telephone, data, cable TV, and other such service line entrances.For projects requiring UL Master Label Certification, a UL 96A compliant surge protection device must be installed at the main service entrance panel. This SPD must comply with UL 96A, UL 1449 Ed. 3, and must have the appropriate UL markings in order to receive the UL Master Label Certification. Devices that meet UL 1449 Ed. 3 alone do not satisfy the new 2011 UL requirements for UL Master Label Certification. The device must meet both UL 1449 Ed. 3 and UL 96A.Our bid includes lightning protection materials for roof circuits and wall downleads only. Below grade grounding systems for all buildings and structures are not included and must be furnished by others.
ERICOERICO, Inc. Contact: Steve Heine
34600 Solon Rd. Phone: 440-528-3752
Solon, OH 44139 Fax 440-848-8592
USA E-mail: [email protected]
Bid Date:
To:
LIGHTNING PROTECTION MATERIALS QUOTATION
System Design Type Conductor Type Materials Building
Roof Material Type
Air Terminal Size
Downleads Component Type
Ground Loop
Roof Type Grounding
Standards Requirements Design Criteria
L.P. Spec. Section:
Drawings:
Addendum Reviewed:
Documents to be provided Terms/Conditions
Upon receipt of order Note: Freight allowed is $1,500.00 net
Following installation
Note: 1)
2)
* Add for UL Certification
** Add for LPI Certification
ERICO, Inc. Reserves the right to charge for design drawings.
See Attached Bill(s) of Materials, Excluded Items, and Comments
Contact Person:
CC MM: Chuck Cooley Steve Heine
CC CSR: Nancy Brown
CADDY® • CADWELD® • ERITECH® • FLEXIBAR® • LENTON®
2/18/2013
Ground Rods are packaged and sold in
bundles of five only.
CADWELD weld metal sold in standard
packages only.
NFPA 780
UL 96, 96A
LPI 175, 176
Submittal DrawingsCatalog Data
UL Master Label*
UL Letter of Findings
UL Reconditioned Master Label
LPI Certification**
LPI Conditional Certification
Net 30 Days
Add Sales Tax
30 Days Acceptance from:
Exposed
Semi-Concealed
Concealed
Cable
Structural Steel
Cable
Structural Steel
Flat
Standing Seam
Copper
Aluminum
Stamped
Cast
Mechanical
CADWELD
Class I
Class II
12 in.
24 in.
Class I/II
4/0
Re: 22 Plex Office Contact: Steve Heine
Job No: GA-132991
25 ft.
606 ft.
LIGHTNING PROTECTION MATERIALS LINEAR FOOT QUOTATION
Qty Total
* 775 Feet of Perimeter Cable (Includes air terminals, bases, conductor, and holders) 775 $1,253.44
* 450 Feet of Cross Run Cable (Includes air terminals, bases, conductor, and holders) 450 $570.21* 7 Secondary Bonds 10 70 $87.24
* 7 Downleads to Grade 18 Feet 126 $507.79
7 Grounding Locations 10 70 $481.58
1 CADWELD Materials (Includes, molds, shots, and igniter) $368.52
List Price for Materials Only $3,922.80
List Price for UL96A Compliant Surge Protection Device * See Note 2 $850.00
Price for UL Master Label Certification $1,400.00
Total Price $6,172.80
Installation time in man hours (Inexperienced Installer) 67
Installation time in man hours (Experienced Installer) 41
1267 Roof Cable 126 Downlead Cable Ground Loop Cable
48 Air Terminals/Bases 445 Cable Holders/Clips 14 Miscellaneous Fittings
Thru-Roof Penetrations 70 PVC 7 Ground Rods/Clamps
1
2
3
4
5
6
7
8
9
10
11
12
13
Bonding of interior or exterior doors, windows, and louvers.
Bonding of interior or exterior electrical or mechanical equipment, etc.
Grounding resistance tests and ground rod test wells.
Labor estimates and materials for cutting and patching paved or landscaped areas for process of installing
lightning protection system grounding.
Compliance to NEC 250-46. Contractor is responsible for maintaining a 6'-0" distance from lightning
protection system conductor to all conductive metal components.
Lightning protection materials for any other buildings, additions, and structures, new or existing.
Our bid includes lightning protection materials for roof circuits and wall downleads only. Below grade
grounding systems for all buildings and structures are not included and must be furnished by others.
1" PVC conduit, fastened and installed as raceway for routing exposed or concealed downlead cables.
Trenching and backfilling for below grade routing of counterpoise ground loop cable at 18" minimum depth.
Bond to underground metal piping systems entering buildings as required by UL, NFPA, and LPI standards on
water, gas, storm, sanitary, conduit, and other such pipes.
Special systems grounding of electrical system bonds to building steel, signal reference grounds, bus bars,
electrical service entrance grounding, transformer grounding, telephone system grounding, etc.
For projects requiring UL Master Label Certification: As of 12/03/2012, UL no longer requires the
inspection of surge protection devices at the main service entrance, but that omission will be noted on
the certificate. ERICO still recommends a UL 96A and UL 1449 Ed. 3 compliant device, and has
included it in this quotation.
ERICO
Height of Building
Perimeter of Building
Description
Unless otherwise specified above, the following items ARE NOT INCLUDED in the lot materials price but are
necessary to provide a complete lightning protection system per standards and specifications.
Surge protectors, required on certified lightning protection systems per UL, NFPA, and LPI standards on
electrical, telephone, data, cable TV, and other such service line entrances.
UL and the UL logo are trademarks of UL LLC © 2012 Unauthorized reproduction or alteration of this certificate constitutes fraud.
This certificate is for reference use only. To verify Master Label Certificate, please refer to website: https://lps.ul.com
Lightning Protection Services
Certificate Number 735B-15F9DD
Inspection Date 05/30/2013
Expiration Date 05/30/2018
MASTER LABEL® CERTIFICATE OF INSPECTION For
LIGHTNING PROTECTION SYSTEMS
This certificate reports the findings of an inspection by Underwriters Laboratories of a lightning protection system. The inspection was conducted using all applicable sections of UL 96A, Installation Requirements for Lightning Protection Systems, Twelfth edition, issued on 10/04/2010. The system was found to comply with these requirements at the time of inspection.
The following item(s) were omitted from the scope of the Inspection:
Communication surge protection system was not inspected. Surge protection devices are an integral component of a complete lightning protection system and should be provided on all incoming and exiting electric, power, data, and communication services.
Structure: BAPTIST MEDICAL OFFICE BUILDING CLAY COUNTY (EXCLUDING INCONNECTING WALKWAY) Address: 1747 BAPTIST CLAY DRIVE FLEMING ISLAND, FL 32003 UNITED STATES
Installing Company: ERICO INC Address: 34600 SOLON RD SOLON, OH 44139
This certificate is only valid for five years based on UL's reasonable estimate that the system will remain unchanged. Any modifications to electrical, mechanical or communication systems of the structure will affect lightning protection devices and may render protection afforded by this system ineffective. These changes will invalidate our certificate earlier than the five year period.
Underwriters Laboratories 333 PFINGSTEN ROAD, NORTHBROOK, ILLINOIS 60062