Upload
hikmah-miladiyah
View
231
Download
0
Embed Size (px)
Citation preview
8/22/2019 Whats Up Gold Faq
1/26
In this tutorial we will walk through configuring WhatsUp Gold to monitor a probe on the Senturion
Environmental Monitor.
Applies to:
Senturion Environmental Monitor
Senturion Lite Environmental Monitor
Prerequisites:
Working copy of WhatsUp Gold 12.3 (other versions work as well)
Sensatronics Senturion SNMP MIBS (Get them here)
SensatronicsSenturionorSenturion Liteconnected to network
Sections:
Section 1 - Install Senturion MIBS How to install the SensatronicsSenturion MIBS into WUG
Section 2 - Add the device How to add the device
Section 3 - Configure thePerformance Monitor
How to add a performance monitor fora probe.
Section 4 - Configure the Active
Monitor
How to setup Active Monitor
Thresholds and Alerts
Section 5 - Viewing the data How to view Performance Monitor andActive Monitor data
Section 1: Install Senturion MIBS
Download, extract and copy the sensatronics-senturion-my and sensatronics-smi mibs to the
C:/Program Files/ipswitch/whatsup/data/mibs/ directory
http://sensatronics.com/images/sensaproducts/it/monitors/senturion/downloads/senturion_mibs.ziphttp://sensatronics.com/index.php/products/it-products/144.htmlhttp://sensatronics.com/index.php/products/it-products/144.htmlhttp://sensatronics.com/index.php/products/it-products/144.htmlhttp://sensatronics.com/index.php/products/industrial-products/42.htmlhttp://sensatronics.com/index.php/products/industrial-products/42.htmlhttp://sensatronics.com/index.php/products/industrial-products/42.htmlhttp://sensatronics.com/index.php/whatsup-gold/198.html#Section1%23Section1http://sensatronics.com/index.php/whatsup-gold/198.html#Section1%23Section1http://sensatronics.com/index.php/whatsup-gold/198.html#Section2%23Section2http://sensatronics.com/index.php/whatsup-gold/198.html#Section2%23Section2http://sensatronics.com/index.php/whatsup-gold/198.html#Section3%23Section3http://sensatronics.com/index.php/whatsup-gold/198.html#Section3%23Section3http://sensatronics.com/index.php/whatsup-gold/198.html#Section3%23Section3http://sensatronics.com/index.php/whatsup-gold/198.html#Section4%23Section4http://sensatronics.com/index.php/whatsup-gold/198.html#Section4%23Section4http://sensatronics.com/index.php/whatsup-gold/198.html#Section4%23Section4http://sensatronics.com/index.php/whatsup-gold/198.html#Section5%23Section5http://sensatronics.com/index.php/whatsup-gold/198.html#Section5%23Section5http://sensatronics.com/images/sensaproducts/it/monitors/senturion/downloads/senturion_mibs.ziphttp://sensatronics.com/index.php/products/it-products/144.htmlhttp://sensatronics.com/index.php/products/industrial-products/42.htmlhttp://sensatronics.com/index.php/whatsup-gold/198.html#Section1%23Section1http://sensatronics.com/index.php/whatsup-gold/198.html#Section2%23Section2http://sensatronics.com/index.php/whatsup-gold/198.html#Section3%23Section3http://sensatronics.com/index.php/whatsup-gold/198.html#Section3%23Section3http://sensatronics.com/index.php/whatsup-gold/198.html#Section4%23Section4http://sensatronics.com/index.php/whatsup-gold/198.html#Section4%23Section4http://sensatronics.com/index.php/whatsup-gold/198.html#Section5%23Section58/22/2019 Whats Up Gold Faq
2/26
Restart the "Ipswitch WhatsUp Engine in Windows/Services so the new mibs
will be recognized by the system
Section 2: Add the Device
Open the WhatsUp Gold admin console and add a new device (File/New/New Device....)
8/22/2019 Whats Up Gold Faq
3/26
Enter the IP address of your Senturion / Senturion Lite
Click on "Credentials" in the properties section and select your
"SNMP v1/v2/v3 credentials" from the drop-down. The default for the Senturion is "Public"
8/22/2019 Whats Up Gold Faq
4/26
Section 3: Configure Performance Monitors
Click "Performance Monitors" in the properties section and
Click the "New" button to add a new individual performance monitor
8/22/2019 Whats Up Gold Faq
5/26
Select a performance monitor type of "SNMP Performance Monitor and click the "OK" button
8/22/2019 Whats Up Gold Faq
6/26
Enter a name for your probe, here we are using "Senturion Local Temperature"
Clip the Ellipses (...) button next to the Performance Counter Instance field.
Browse to the Probe1Value in the SNMP MIB Walker.
private/enterprises/sensatronics/consumerproducts/envmonitors/productsenturion/probeinfo/probevalues
Select "probe1Value" and click the OK button
8/22/2019 Whats Up Gold Faq
7/26
You should now see the oid for that probe in the performance counter f ield.
Set your preferred collection interval, Timeout, and Retries. Click the "OK" button
8/22/2019 Whats Up Gold Faq
8/26
You should now see your newly created probe performance monitor in the individual performance monitors list.
Section 4: Configure Active Monitors
Select "Active Monitors" from the Properties Section and click the "Add..." button to add a new Active Monitor.
8/22/2019 Whats Up Gold Faq
9/26
Don't select a monitor from the drop-down yet. Instead, click the ellipses (...) button
to the right of the drop-down to create a new Active Monitor type
8/22/2019 Whats Up Gold Faq
10/26
Click the "New" button
8/22/2019 Whats Up Gold Faq
11/26
Select "SNMP Monior" and click the "OK" button
Name the SNMP monitor after your probe name. In this Case we are using "Senturion Local Temperature"
Click the Ellipses (...) button to the right of the Object ID - Instance field.
Enter the IP address of your Senturion, select your SNMP credentials and click the "OK" Button
8/22/2019 Whats Up Gold Faq
12/26
Browse to the Probe1Value in the SNMP MIB Walker.
private/enterprises/sensatronics/consumerproducts/envmonitors/productsenturion/probeinfo/probevalues
Select "probe1Value" and click the OK button
8/22/2019 Whats Up Gold Faq
13/26
You should see the probe's object ID appear in the "Object ID" field
Change the Check Type to "Range of Values"
Enter your minimum and maximum threshold values in the Low and High value fields.
Note: The Senturion stores the temperature value as a whole number. So a value of 600 actually means 60.0 degrees
and a value 850 means 85.0 degrees etc.
Click the "OK" button
8/22/2019 Whats Up Gold Faq
14/26
Click the "OK" button in the Active Monitor Library screen
8/22/2019 Whats Up Gold Faq
15/26
Select your newly created Active Monitor type from the dropdown and Click the "Next" button
8/22/2019 Whats Up Gold Faq
16/26
Click "Next" in the Set Polling Properties Section
8/22/2019 Whats Up Gold Faq
17/26
Setup your Actions. Select either Action Policy or setup individual actions.
8/22/2019 Whats Up Gold Faq
18/26
Select an action policy if desired:
Select the Apply individual actions radio button and click the "Add" button to setup individual actions for this monitor.
8/22/2019 Whats Up Gold Faq
19/26
Create a new action or select existing action
We set an individual action to email the Admin when the Monitor is out of range for 20 minutes
8/22/2019 Whats Up Gold Faq
20/26
Click the "Finish" Button
8/22/2019 Whats Up Gold Faq
21/26
You should see the new probe monitor show up in the Active Monitors list
Click the "OK" button
You should see the newly added device in the device list
Section 5: Viewing the Data
Right Click on the device and select "Poll Now"
8/22/2019 Whats Up Gold Faq
22/26
Right-click on the device again and select "Device Status Report"
This will load the web console. Enter your username and password and login.
8/22/2019 Whats Up Gold Faq
23/26
You will see your newly added device status.
Click on your probe name in the "Device Performance Monitor Summary"
8/22/2019 Whats Up Gold Faq
24/26
You will see a graph load and you should see it starting to graph data on the right
8/22/2019 Whats Up Gold Faq
25/26
Go back to your Device Status screen and click on the name of your probe in the "Device Active Monitor States" section. Youshold see a data point on the right
side of the Monitor State graph
8/22/2019 Whats Up Gold Faq
26/26
You can repeat the previous steps for each probe you have connected to the Senturion.