Upload
cesardako
View
212
Download
0
Embed Size (px)
DESCRIPTION
85-99% of water treatmentplant electric consumptiongoes to raw water & wellpumps, high service pumps,filter backwash pumps,distribution booster pumps
Citation preview
1
Proprietary & Confidential
Rentricity
OverviewOverview
1
www.rentricity.com 160 Varick St. New York, NY 10013
©2010 RENTRICITY INC. ALL RIGHTS RESERVED • STRICTLY CONFIDENTIAL • PERMISSION REQUIRED FOR DISTRIBUTION
Proprietary & Confidential
Rentricity Provides Clean Energy Recovery for the Potable, Waste and Industrial Water Industries
Water Company Services
Benefits
• Offset Electricity Rate Increases
• Corporate Responsibility
• Energy Recovery & Monitoring using Flow-to-Wire™ Systems
2
Increases
• Revenue Generation
• Public Goodwill
• Reduced Carbon Footprint
• Security & Monitoring
• Operational Efficiency
©2010 RENTRICITY INC. ALL RIGHTS RESERVED • STRICTLY CONFIDENTIAL • PERMISSION REQUIRED FOR DISTRIBUTION
2
Drinking water and wastewater consume:
- 3% of domestic electricity
Water - Energy Connection
Proprietary & Confidential
- 7% of worldwide electricity
- 19% of California electricity
Water utility energy use varies from 0.25 to 3.5 kWh per 1,000 gallons of drinking water produced & delivered
3
85-99% of water treatment plant electric consumption goes to raw water & well pumps, high service pumps, filter backwash pumps, distribution booster pumps
Source: American Water Presentation – Institute of Public Utilities Conference – 12/11/08
©2010 RENTRICITY INC. ALL RIGHTS RESERVED • STRICTLY CONFIDENTIAL • PERMISSION REQUIRED FOR DISTRIBUTION
Pipes ~ Pressure ~ Power™
Proprietary & Confidential
4©2010 RENTRICITY INC. ALL RIGHTS RESERVED • STRICTLY CONFIDENTIAL • PERMISSION REQUIRED FOR DISTRIBUTION
3
• 2 MGD
• 45 PSI
Proprietary & Confidential
3 Potable Water Application Targets Wastewater & Industrial in Planning Stages
• 9 MGD
• 40 PSI
Urban Site - 50 kW Mandated Release - 100 kW• 25 MGD
• 25 MGD
• 12 feet
• 40 PSI
5
Industrial/Wastewater – 40 kWTransfer Station - 200 kW©2010 RENTRICITY INC. ALL RIGHTS RESERVED • STRICTLY CONFIDENTIAL • PERMISSION REQUIRED FOR DISTRIBUTION
• 35 PSI• 12 feet
Proprietary & Confidential
Rentricity Model for Drinking Water, Wastewater & Industrial Water Systems
6©2010 RENTRICITY INC. ALL RIGHTS RESERVED • STRICTLY CONFIDENTIAL • PERMISSION REQUIRED FOR DISTRIBUTION
4
• Turbine-Generator
Flow-to-Wiresm Components
Proprietary & Confidential
Proven Components, Uniquely Configured
• Interconnection Package
• Pressure Reduction Valve
• Integrated Sensors
7
Rentricity patents are under development
80%+ Standardized
Lifespan Up to 40 Years
©2010 RENTRICITY INC. ALL RIGHTS RESERVED • STRICTLY CONFIDENTIAL • PERMISSION REQUIRED FOR DISTRIBUTION
Proprietary & Confidential
AFTER
Demonstration Installation
C t l B t G d L l
BEFORE
8©2010 RENTRICITY INC. ALL RIGHTS RESERVED • STRICTLY CONFIDENTIAL • PERMISSION REQUIRED FOR DISTRIBUTION
Control Boxes at Grade Level
Meter
5
Proprietary & Confidential
Current 2009 Development Projects
9©2010 RENTRICITY INC. ALL RIGHTS RESERVED • STRICTLY CONFIDENTIAL • PERMISSION REQUIRED FOR DISTRIBUTION
California Water225 kW
Transfer Station
Pennsylvania
30 kW
Release
New England
50 kW
PRV
California
225 kW
PSV
10
Contact Information
P: 617.733.9703 Allie Corless [email protected]
©2009 RENTRICITY INC. ALL RIGHTS RESERVED • STRICTLY CONFIDENTIAL • PERMISSION REQUIRED FOR DISTRIBUTION