16
WEST HARRIS COUNTY REGIONAL WATER AUTHORIT LOCATION MAP BRAZOS RIVER ALMEDA RD BISSONETT 6 TEXAS 59 90A RICHMOND AVE WESTHEIMER RD RESERVOIR BARKER 10 8 BELTWAY 610 GALVESTON BAY 35 TEXAS 288 TEXAS TEXAS FUQUA 610 FAIRMONT PKWY 8 BELTWAY 45 225 10 FM 1960 LITTLE YORK 290 45 CYPRESS CREEK HARDY TOLL ROAD LAKE HOUSTON HUMBLE-ATASCOSITA RD MT. HOUSTON RD 90 59 SPRING STUEBNER R.R. NOT TO SCALE C H A N N E L S H I P H O U S T O N B A Y O U B U F F A L O SURFACE WATER SUPPLY PROJECT PROJECT LOCATION WHCRWA / NFBWA - SURFACE WATER SUPPLY PROJECT KINDER MORGAN KM"X" PROJECT LIMITS DESCRIPTION VICINITY MAP KEY MAP NO. 0000 GIMS MAP NO. 00000 ZIP CODE NO. 00000 BOARD OF DIRECTORS DIRECTOR PRECINCT #1 DIRECTOR PRECINCT #2 DIRECTOR PRECINCT #3 DIRECTOR PRECINCT #7 DIRECTOR PRECINCT #8 DIRECTOR PRECINCT #9 DIRECTOR PRECINCT #5 DIRECTOR PRECINCT #6 DIRECTOR PRECINCT #4 LARRY A. WEPPLER JOHN WHEELER ERIC HANSEN GARY STRUZICK MARK G. JANNECK DENNIS GORDEN MIKE OWENS DOUGLAS C. POSTLE MICHAEL THORNHILL WEST HARRIS COUNTY REGIONAL WATER AUTHORITY BOARD OF DIRECTORS DIRECTOR PRECINCT #1 DIRECTOR PRECINCT #2 DIRECTOR PRECINCT #3 DIRECTOR PRECINCT #7 DIRECTOR PRECINCT #5 DIRECTOR PRECINCT #6 DIRECTOR PRECINCT #4 _______________ ROBERT DARDEN BRUCE FAY ________________ ROBERT L. PATTON PETER HOUGHTON MELONY F. GAY NORTH FORT BEND WATER AUTHORITY XX% SUBMITTAL *CONSTRUCTION IN HARRIS COUNTY FLOOD CONTROL DISCTRICT RIGHT-OF-WAY REQUIRES: SITE PLANS MUST BE APPROVED PRIOR TO OBTAINING THE REQUIRED HCFCD RIGHT-OF-WAY NOTIFICATION. BE ADVISED THAT THE HCFCD RIGHT-OF-WAY NOTIFICATION IS SEPARATE FROM THE SITE DEVELOPMENT PERMIT PACKAGE 1.) HCFCD RIGHT-OF-WAY NOTIFICATION (PERMIT) 2.) HCFCD 48-HR PRE-CONSTRUCTION NOTICE BOTH ARE REQUIRED PRIOR TO ENTERING OR WORKING WITHIN HARRIS COUNTY FLOOD CONTROL DISTRICT RIGHT-OF-WAY. THE HCFCD RIGHT-OF-WAY NOTIFICATION AND 48-HOUR NOTICE MUST BE PROVIDED TO HCFCD AT [email protected] TO APPLY FOR THE HCFCD RIGHT-OF-WAY NOTIFICATION PLEASE GO TO http://apps.harriscountytx.gov/EPermits AND APPLY FOR THE HCFCD ROW UNDER ROW NOTIFICATION. FAILURE TO PROVIDE BOTH ITEMS COULD RESULT IN PROJECT DELAYS. 48 HOUR NOTICE CONTRACTOR SHALL NOTIFY HARRIS COUNTY PRIOR TO COMMENCING CONSTRUCTION AND/OR BACKFILLING ANY UTILITIES. CONTRACTOR(S) TO CONTACT MARC BARBE WITH PUBLIC REVIEW DEPARTMENT @ (713-274-3937) OR ([email protected]) Program Manager DANNENBAUM ENGINEERING CORPORATION 08/31/2019 Date Registration Number Engineer INTERIM REVIEW ONLY John D. Doe XXXXX Not to be used for construction, bidding, permit or regulatory approval purposes.This document is released for the purpose of interim review under the authority of: Engineer of Record Texas Registered Engineering Firm F-#XXX Company Name Address Telephone No. Texas Firm No. G-01

WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

LOCATION MAP

B

R

A

Z

O

S

R

I

V

E

R

A

L

M

E

D

A

R

D

B

I

S

S

O

N

E

T

T

6

TEXAS

59

90A

RICHMOND AVE

WESTHEIMER RD

RESERVOIR

BARKER

10

8

BELTWAY

610

GA

LV

ES

TO

N B

AY

35

TEXAS

288

TEXAS

TEXAS

FUQUA

610

FAIRMONT PKWY

8

BELTWAY

45

225

10

F

M

1

9

6

0

LIT

TLE

YO

RK

290

45

CY

PR

ES

S C

RE

EK

H

A

R

D

Y

T

O

L

L

R

O

A

D

L

A

K

E

H

O

U

S

T

O

N

H

U

M

B

L

E

-

A

T

A

S

C

O

S

I

T

A

R

D

MT. HOUSTON RD

90

59

S

P

R

IN

G

C

R

E

E

K

C

R

E

E

K

2920

SPRING STUEBNER

R

.R

.

NOT TO SCALE

C

H

A

N

N

E

L

S

H

I P

H

O

U

S T

O

N

BAY

O

U

BU

F

F

A

L

O

SURFACE WATER SUPPLY PROJECT

PROJECT

LOCATION

WH

CR

WA

/ N

FBW

A -

SUR

FAC

E W

ATE

R S

UPP

LY P

RO

JEC

T

KINDER MORGAN KM"X"

PROJECT LIMITS

DESCRIPTION

VICINITY MAP

KEY MAP NO. 0000

GIMS MAP NO. 00000

ZIP CODE NO. 00000

BOARD OF DIRECTORS

DIRECTOR PRECINCT #1

DIRECTOR PRECINCT #2

DIRECTOR PRECINCT #3

DIRECTOR PRECINCT #7

DIRECTOR PRECINCT #8

DIRECTOR PRECINCT #9

DIRECTOR PRECINCT #5

DIRECTOR PRECINCT #6

DIRECTOR PRECINCT #4

LARRY A. WEPPLER

JOHN WHEELER

ERIC HANSEN

GARY STRUZICK

MARK G. JANNECK

DENNIS GORDEN

MIKE OWENS

DOUGLAS C. POSTLE

MICHAEL THORNHILL

WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

BOARD OF DIRECTORS

DIRECTOR PRECINCT #1

DIRECTOR PRECINCT #2

DIRECTOR PRECINCT #3

DIRECTOR PRECINCT #7

DIRECTOR PRECINCT #5

DIRECTOR PRECINCT #6

DIRECTOR PRECINCT #4

_______________

ROBERT DARDEN

BRUCE FAY

________________

ROBERT L. PATTON

PETER HOUGHTON

MELONY F. GAY

NORTH FORT BEND WATER AUTHORITY

XX% SUBMITTAL

*CONSTRUCTION IN HARRIS COUNTY FLOOD CONTROL DISCTRICT RIGHT-OF-WAY REQUIRES:

SITE PLANS MUST BE APPROVED PRIOR TO OBTAINING THE REQUIRED HCFCD RIGHT-OF-WAY NOTIFICATION.

BE ADVISED THAT THE HCFCD RIGHT-OF-WAY NOTIFICATION IS SEPARATE FROM THE SITE DEVELOPMENT

PERMIT PACKAGE

1.) HCFCD RIGHT-OF-WAY NOTIFICATION (PERMIT)

2.) HCFCD 48-HR PRE-CONSTRUCTION NOTICE

BOTH ARE REQUIRED PRIOR TO ENTERING OR WORKING WITHIN HARRIS COUNTY FLOOD CONTROL DISTRICT

RIGHT-OF-WAY. THE HCFCD RIGHT-OF-WAY NOTIFICATION AND 48-HOUR NOTICE MUST BE PROVIDED TO

HCFCD AT [email protected]

TO APPLY FOR THE HCFCD RIGHT-OF-WAY NOTIFICATION PLEASE GO TO

http://apps.harriscountytx.gov/EPermits AND APPLY FOR THE HCFCD ROW UNDER ROW NOTIFICATION.

FAILURE TO PROVIDE BOTH ITEMS COULD RESULT IN PROJECT DELAYS.

48 HOUR NOTICE

CONTRACTOR SHALL NOTIFY HARRIS COUNTY PRIOR TO COMMENCING CONSTRUCTION AND/OR

BACKFILLING ANY UTILITIES. CONTRACTOR(S) TO CONTACT MARC BARBE WITH PUBLIC REVIEW

DEPARTMENT @ (713-274-3937) OR ([email protected])

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

G-01

AutoCAD SHX Text
ISSUE DATE: MONTH/DAY/YEAR
AutoCAD SHX Text
ILMS NO.
AutoCAD SHX Text
C.O.H. LOG. NO.
AutoCAD SHX Text
ILMS NO.
AutoCAD SHX Text
C.O.H. LOG. NO.
AutoCAD SHX Text
ONE-CALL NOTIFICATION SYSTEM CALL BEFORE YOU DIG!!! (713) 223-4567 (New Statewide Number Outside Houston) 1-800-545-6005
AutoCAD SHX Text
ILMS NO.
AutoCAD SHX Text
C.O.H. LOG. NO.
AutoCAD SHX Text
ONE-CALL NOTIFICATION SYSTEM CALL BEFORE YOU DIG!!! (713) 223-4567 (New Statewide Number Outside Houston) 1-800-545-6005
AutoCAD SHX Text
CONSTRUCTION ACTIVIES ALLOWED ONLY IN AREAS WHERE THE AUTHORITY HAS EASEMENTS OR THE LEGAL RIGHT TO BE PRESENT
AutoCAD SHX Text
DESIGN VARIANCE GIVEN BY CITY ENGINEER BY EMAIL DATED 1/22/2019. CITY SIGNATURES DO NOT REPRESENT COMPLIANCE WITH THE CITY'S DESIGN STANDARDS, ONLY ACKNOWLEDGEMENT OF THE PROJECT FOR THE PURPOSES OF CONSTRUCTION AND PERMITTING.
AutoCAD SHX Text
NO.
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
DATE
AutoCAD SHX Text
MM/DD/YY
AutoCAD SHX Text
MM/DD/YY
AutoCAD SHX Text
MM/DD/YY
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
BRIEF DESCRIPTION
AutoCAD SHX Text
BRIEF DESCRIPTION
AutoCAD SHX Text
BRIEF DESCRIPTION
AutoCAD SHX Text
APP.
AutoCAD SHX Text
XXX
AutoCAD SHX Text
XXX
AutoCAD SHX Text
XXX
AutoCAD SHX Text
SHEET NO XX OF XX SHEETS
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
STORM WATER QUALITY
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
CITY ENGINEER DATE
AutoCAD SHX Text
DIRECTOR OF DATE HOUSTON PUBLIC WORKS
AutoCAD SHX Text
TRAFFIC SIGNAL
Page 2: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

CULVERT PIPE

AT&T TEXAS/SWBT PEDESTAL, HISTORICAL MARKER

R.O.W. LINE S & W

R.O.W. LINE N & E

DITCH OR CURB LINE S & W

DITCH OR CURB LINE N & E

PROPERTY LINE (R.O.W.)

GAS LINE OR PIPELINE

CHAIN LINK, WOOD FENCE

WATER LINE 30" DIA & LARGER

STM SEWER LINE 30" DIA & LARGER

SAN SEWER LINE 24" DIA. & SMALLER

W.H.C.R.W.A. SURVEY MARKER, MONUMENT MARKER

TRAFFIC, METRO, BUSINESS, STOP SIGNS

IRON ROD/POLE

TRAFFIC SIGNAL, SIGNAL POLE

STORM "B-B" INLET

DOWN GUY

POWER POLE, TELEPHONE & ELEC. POLE

WATER VALVE

WATER METER

FIRE HYDRANT

GAS VALVE

GAS METER

CLEANOUT

SAN MANHOLE, STORM MANHOLE

TREE

SHRUB OR BUSH

AT&T TEXAS/SWBT MANHOLE

STORM INLET, GRATE

WOOD POST, BRICK COLUMN, BRICK PILLAR

STORM "B" INLET

SAN SEWER LINE 30" DIA. & LARGER

SOIL BORING & PIEZOMETER LOCATION

HEDGE

MAILBOX

METAL POST

SOIL BORING LOCATION

BASELINE

GAS LINE

T.S.V. & BOX

BUTTERFLY VALVE

STORM "BB" INLET

ACCESS MANHOLE

CATHODIC PROTECTION

RECTIFIER AND DEEP ANODE

R

R

STM SEWER LINE 30" DIA & LARGER

CURB LINE

LOT LINES

EDGE OF ASPHALT

STM SEWER LINE 24" DIA. & SMALLER

WATER LINE 24" DIA. & SMALLER

AT&T TEXAS/SWBT CONDUIT

AT&T TEXAS/SWBT LINE

LIGHT STANDARD

ELECTRICAL BOX

EXISTING PLAN LEGEND

CATHODIC PROTECTION

TEST STATION

PROPOSED LEGEND

EASEMENT LINE

WHCRWA EASEMENT LINE

AIR VENT w/3 BOLLARDS

AIR VENT w/1 BOLLARD

CENTERPOINT ENERGY CONDUIT

CENTERPOINT ENERGY OVERHEAD LINES

PP

WATER LINE 30" DIA & LARGER

WATER LINE 24" DIA. & SMALLER

BASELINE, CENTER LINE OF RIGHT-OF-WAY

SAN SEWER LINE 24" DIA. & SMALLER

SAN SEWER LINE 30" DIA. & LARGER

STM SEWER LINE 24" DIA. & SMALLER

LINE

INFORMATION OBTAINED FROM RECORD

DRAWINGS, NOT FIELD VERIFIED.

PIPELINE MARKER

EXISTING PROFILE LEGEND

UTILITY MARKER

LINE

DRAWING LIST

DESCRIPTIONSHEETDWG No

DRAWING LIST

DESCRIPTIONSHEETDWG No

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

46

47

49

50

51

52

16

17

18

19

20

21

22

23

24

25

26

27

35

36

37

38

39

40

41

42

43

44

48

COVER SHEET

HARRIS COUNTY EXPRESS REVIEW SHEET

INDEX OF DRAWINGS AND LEGEND

GENERAL CONSTRUCTION NOTES

SHEET LAYOUT MAP AND CORE BORING PLAN

SURVEY CONTROL MAP (SHEET 1 OF 3)

SURVEY CONTROL MAP (SHEET 2 OF 3)

SURVEY CONTROL MAP (SHEET 3 OF 3)

PLAN AND PROFILE STATION 0+00 TO 5+00

PLAN AND PROFILE STATION 5+00 TO 10+00

PLAN AND PROFILE STATION 10+00 TO 15+00

PLAN AND PROFILE STATION 15+00 TO 20+00

PLAN AND PROFILE STATION 20+00 TO 25+00

PLAN AND PROFILE STATION 25+00 TO 30+00

PLAN AND PROFILE STATION 30+00 TO 35+00

STORM WATER POLLUTION PREVENTION PLANS (SHEET 1 OF 4)

STORM WATER POLLUTION PREVENTION PLANS (SHEET 2 OF 4)

STORM WATER POLLUTION PREVENTION PLANS (SHEET 3 OF 4)

STORM WATER POLLUTION PREVENTION PLANS (SHEET 4 OF 4)

STORM WATER POLLUTION PREVENTION DETAILS

TRAFFIC CONTROL PLAN

TRAFFIC CONTROL DETAILS

PROJECT SIGN DETAIL

STEEL PIPE DETAILS

PRESTRESSED CONCRETE CYLINDER PIPE DETAILS

TUNNEL AND CASING DETAILS

AIR VALVE IN SERVICE MANHOLE DETAILS

VENT PIPING DETAILS

VALVE AND SERVICE MANHOLE DETAILS

MANHOLE COVER DETAILS

STANDARD WATER MAIN DETAILS

EXCAVATION, BEDDING, BACKFILL AND PAVEMENT REPAIR DETAILS

BEDDING & BACKFILL AUGER PIT & SANITARY SEWER CROSSING DETAIL

TREE PROTECTION DETAILS

CATHODIC PROTECTION TEST STATION DETAILS 1 OF 4

CATHODIC PROTECTION TEST STATION DETAILS 2 OF 4

CATHODIC PROTECTION TEST STATION DETAILS 3 OF 4

CATHODIC PROTECTION TEST STATION DETAILS 4 OF 4

CATHODIC PROTECTION RECTIFIER DETAILS 1 OF 2

CATHODIC PROTECTION RECTIFIER DETAILS 2 OF 2

CATHODIC PROTECTION INSULATING JOINT DETAILS

CATHODIC PROTECTION JOINT BONDING

CATHODIC PROTECTION MISCELLANEOUS DETAILS 1 OF 2

CATHODIC PROTECTION MISCELLANEOUS DETAILS 2 OF 2

D01

D02

D03

D04

D05

D06

D07

D08

D09

D10

D11

D12

CP2

CP3

CP4

CP5

CP6

CP7

CP8

CP9

CP10

CP11

33

34

ELECTRICAL METERING/FLOW CONTROL STATION POWER PLAN

ELECTRICAL METERING/FLOW CONTROL STATION PLANS AND DETAILS

ELECTRICAL CONDUIT AND CABLE SCHEDULE YARD LIGHT DETAIL

ELECTRICAL CONTROL PANEL LAYOUT SHEET 1 OF 2

ELECTRICAL CONTROL PANEL LAYOUT SHEET 2 OF 2

ELECTRICAL POWER WIRING DIAGRAM SHEET 1 OF 2

ELECTRICAL POWER WIRING DIAGRAM SHEET 2 OF 2

ELECTRICAL CONTROL WIRING DIAGRAM SHEET 1 OF 5

ELECTRICAL CONTROL WIRING DIAGRAM SHEET 2 OF 5

ELECTRICAL CONTROL WIRING DIAGRAM SHEET 3 OF 5

ELECTRICAL CONTROL WIRING DIAGRAM SHEET 4 OF 5

ELECTRICAL CONTROL WIRING DIAGRAM SHEET 5 OF 5

ELECTRICAL CONTROL PANEL AND SUN SHIELD DETAILS

ELECTRICAL MISCELLANEOUS DETAILS SHEET 1 OF 2

ELECTRICAL MISCELLANEOUS DETAILS SHEET 2 OF 2

E01

E02

E03

E04

E05

E06

E07

E08

E09

E10

E11

E12

E13

E14

E15

WATER LINE 24" AND SMALLER

WATER LINE 30" DIA & LARGER

WATER LINE 30" DIA & LARGER

IN TUNNEL

WATER LINE 24" DIA & SMALLER

IN TUNNEL

PROPOSED LEGEND

WATER LINE 24" DIA & SMALLER

WATER LINE 30" DIA & LARGER

WATER LINE 30" DIA & LARGER

TRENCHLESS

X

GATE VALVE w/BOX

BUTTERFLY VALVE

w/OPERATOR M.H.

INTERNAL ELLIPTICAL DISHED

HEAD PLUG

MANHOLE, AI/VR

@

B.L.

B/F

BL.

B/S

C.L.

C-C

C.O.

CONC.

C.G.M.P.

C.M.P.

D.E.

D.I.P.

DESC.

DIA.

E.

E.P.

EL.

EXIST.

F.H.

F.L.

F.M.

F.V.

FL.

GRP

H.M.A.C.

H.P.

I.P.

I.R.

INFL.

INV. EL.

L.F.

AT

BUILDING LINE

BLIND FLANGE

BASELINE

BACKSLOPE

CENTER LINE

CENTER TO CENTER

CLEAN OUT

CONCRETE

CORRUGATED GALVANIZED

CORRUGATED METAL PIPE

DRAINAGE EASEMENT

DUCTILE IRON PIPE

DESCRIPTION

DIAMETER

EAST

EDGE OF PAVEMENT

ELEVATION

EXISTING

FIRE HYDRANT

FLOOD LIGHT

FORCE MAIN OR FLOW METER

FLUSHING VALVE

FLOW LINE

GROUNDWATER REDUCTION

HOT MIX ASPHALTIC CONCRETE

HIGH PRESSURE

INTERMEDIATE PRESSURE

IRON ROD

INFLUENT

INVERT ELEVATION

LINEAR FEET

L.U.S.T.

LT.

M.A.

M.C.D.

P.C.

P.O.C.

P.R.C.

P.T.

PT.

PROP.

PVMT.

R.

R.C.P.

R.O.W.

R.P.

RED.

RT.

S.

S.S.

S.S.E.

SAN.

SB/BH

SWBT

STA.

STL

STM.

SWR.

T.C.

LEAKING UNDERGROUND

LEFT

MAINTENANCE ACCESS

MULTI CONDUIT DUCT

POINT OF CURVATURE

POINT ON CURVE

POINT OF REVERSE CURVE

POINT OF TANGENCY

POINT

PROPOSED

PAVEMENT

RADIUS

REINFORCED CONCRETE PIPE

RIGHT-OF-WAY

RADIUS POINT

REDUCER

RIGHT

SOUTH

SIDE SLOPE

SANITARY SEWER EASEMENT

SANITARY

SOIL BORING/ BORE HOLE

AT&T TEXAS/SWBT

STATION

STEEL

STORM

SEWER

TOP OF CURB

B.F.V. BUTTERFLY VALVE

CLR.

PI.

CLEARANCE

POINT OF INTERSECTION

D/W

PL

DRIVEWAY

PROPERTY LINE

PVI POINT OF VERTICAL INTERSECTION

ESMT EASEMENT

D.I.C.L. DUCTILE IRON CEMENT LINED

ENT. ENTERGY

AI/VR AIR RELEASE/VACUUM RELEASE

SJRA SAN JACINTO RIVER AUTHORITY

G.V. GATE VALVE

PRV PRESSURE REDUCING VALVE

CP CATHODIC PROTECTION

R RECORD DRAWING NOT FIELD VERIFIED

M.H.

MAX.

MIN.

MANHOLE

MAXIMUM

MINIMUM

N.F.V. NOT FIELD VERIFIED

METAL PIPE

STORAGE TANK

N.G. NATURAL GROUND

N. NORTH

PROGRAM

U.E.

W.

W.L.

W.L.E.

w/

UTILITY EASEMENT

WEST

WATERLINE

WATER LINE EASEMENT

WITH

VPI. VERTICAL POINT INTERSECTION

T.C.E. TEMPORARY CONSTRUCTION

TYP. TYPICAL

TP TOP OF PAVEMENT

EASEMENT

STANDARD ABBREVIATIONS

28

29

30

31

32

COMBINED METER/FLOW CONTROL FLOW MECHANICAL

COMBINED METER/FLOW CONTROL FLOW MECHANICAL

HOTBOX DETAILS

COMBINED METER/FLOW CONTROL FLOW STRUCTURAL

COMBINED METER/FLOW CONTROL FLOW STRUCTURAL

M01

M02

M03

M04

M05

CATHODIC PROTECTION SCHEDULESCP1

45

53

54

55

56

57

58

59

60

61

62

63

64

65

SW1

SW2

SW3

SW4

SW5

TC1

TC2

TS

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

INDEX SHEET

LEGEND & ABBREVIATIONS

XX

HORIZ

VERT

G-02

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\04-General\G-02 Index Of Drawings.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\04-General\G-02 Index Of Drawings.dwg
AutoCAD SHX Text
PLOTTED: 5/27/2020 2:32 PM5/27/2020 2:32 PM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 3: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

ENGINEER'S CERTIFICATION

FLOOD PLAIN STATUS

FLOOD CONTROL DISTRICT CRITERIA

DESCRIPTION OF PROPERTY

HCED SIGNATURE BLOCK

COMMERCIAL / OTHER SITE DRAINAGE WATER AND WASTEWATER

HARRIS COUNTYENGINEERING DEPARTMENT

REVIEW SHEET

HARRIS COUNTY FLOOD CONTROL DISTRICT

ENGINEERING DIVISION

PAVING

DRIVEWAYS (in H.C. ROW only)

TRAFFIC CONSIDERATIONS

RESIDENTIAL / SUBDIVISION DRAINAGE1. 3. 4. 5.2.

7.

8.

CURBING

FIRE APPARATUS ACCESS ROAD

CURB RAMPS 11.

*****

(2001 ADJ.)

6. STORMWATER QUALITY

WORK IN HCFCD RIGHT-OF-WAY9.

LANDSCAPING 12.

PERMITS REQUIRED10.

WORK IN HARRIS COUNTY R.O.W.

FOR PROJECTS LOCATED IN ANY FLOODPLAIN

Development constructed or placed in accordance with these plans will comply with all provisions of the Regulations of Harris County, Texas forFloodplain Management.

No net fill is allowed in the flood plain and no fill is allowed in the floodway.FOUNDATION NOTES: (Applies to only buildings or building additions requiring a class II permit)

All water heaters, furnaces, air conditioning units, electrical distribution panels, and any other mechanical or electrical equipment must be elevated inaccordance with Section 4.05 of Harris County Floodplain regulations.

Any electrical circuit serving a light switch or outlet located below the base (100-year) flood elevation shall be dropped from above and be on aseparate breaker.

All materials used below the (100-year) base flood elevation are on approved FEMA Technical Bulletin 2-08 as Class 5 water-resistant, and approved inaccordance with FEMA Technical Bulletin 1-08 for foundation openings.

Critical facilities located in the 0.2% or 500yr floodplain or 1% or 100yr floodplain shall have the lowest floor elevated to 3 feet or more above the 0.2%flood elevation, or 24 inches above the crown of the adjacent road, which ever results in a higher elevation.

Floodproofing and sealing measures must be taken to ensure that toxic substances will not be displaced by or released into floodwaters.

Access routes elevated to or above the level of the base flood shall be provided to all critical facilities to the extent possible.

A completed as-built certificate must be submitted after the structure is complete and before it is occupied.

The County Engineer's Office will post a final inspection notice on the structure once all requirements have been met.

No fill may be used to elevate structures in the 1% or 100yr flood plain. Structures may be constructed on an open foundation, such as piers, or oncontinuous foundation walls with properly sized and located openings. All foundations are required to be designed by a registered professionalengineer.

All structures shall be designed to withstand a three second gust basic wind speed of 120mph.

Completed *Elevation Certificates to be submitted: one at permitting, a second after the slab is poured or sub-floor is installed and before the framingstarts, and a third is required once construction is finished. *(PER CURRENT FIRM PANEL) to the Harris County Engineering Department, 10555Northwest Freeway, Suite 120, Houston, TX 77092

IF YES, CHECK THE BOX THAT APPLIES TO THIS PROJECT

TO BE FILLED OUT BY HARRIS COUNTY

NOTE: ALL EXISTING AND PROPOSED UTILITIES MUST BEACCURATELY SHOWN & LABELED ON THE SITE PLANS.

NOTE: SEPTIC SYSTEMS REQUIRE H.C. WASTE WATER REVIEW

NOTE: PUBLIC UTILITIES REQUIRE A LETTER FROM THE DISTRICT/MUNICIPALITY AUTHORIZING SERVICE & CONNECTION.THIS IS REQUIRED FOR PLAN APPROVAL.

NOTE: ALL ROADSIDE DITCH OUTFALLS REQUIRE EROSION CONTROL MEASURES.RIPRAP IS NOT ALLOWED AS AN EROSION CONTROL MEASURE IN HARRIS COUNTY ROW.ALL PUMPED DETENTION OUTFALLS TO ROADSIDE DITCHES REQUIRE MANHOLE W/ LEADS.

DOES THE PROPERTY HAVE ANY VIOLATIONS? IF SO PLEASEPROVIDE ALL VIOLATION NUMBERS.

DESIGNTHICKNESSOF PAVING

STABILIZEDSUBGRADE

DEPTH

DESIGNSTRENGTH

OF CONCRETE

STEEL SPACING

LONG. TRANS.

(IN.) (IN.) (PSI) (IN.) (IN.)

NOTE: ALL APPROVED, FINAL PLATS AND ASSOCIATEDCPC101 FORMS MUST BE INCLUDED WITH PLAN SUBMITTAL.OFFSITE SHEET FLOW: (100 YEAR)

OFFSITE SHEET FLOW MAPPING, TOTAL DISCHARGE CALCULATIONS, ANDDESIGN ACCOMODATIONS ARE SHOWN ON SHEET _____ OR, AS PRESENTEDIN THE APPROVED DRAINAGE STUDY ENTITLED _________________________.

TOTAL ACREAGE = _____TOTAL DISCHARGE = _____

NOTE: ALL OFFSITE SHEET FLOW FROM ADJACENT PROPERTIES MUST BEIDENTIFIED AND PROPERLY ACCOUNTED FOR IN THE PROJECT. THE SIGNINGENGINEER HEREBY CERTIFIES THAT THESE AREAS HAVE BEEN ADDRESSED.

NOTE: A COPY OF TCEQ APPROVAL FOR PRIVATE WATER&WASTE WATER SYSTEMS IS REQUIRED FOR PLANAPPROVAL.

BENCHMARK REQUIREMENTS FORPROPOSED BRIDGES AND OR NEW RESIDENTIAL SUBIDIVSIONS

When the County Engineer has determined that a new benchmark will be required to be established forthe proposed project, the developer shall be required to install a benchmark per section 8.0, part 2 of theHarris County Infrastructure Regulations.

Is a new Benchmark required for this project? (to be determined by Harris County) [__] yes [__] no

If a new Benchmark is required, the proposed benchmark information is shown on sheets ____

NOTE: DEDICATED UNDERGROUND FIRE LINES MUST BE SUBMITTEDTOTHE HARRIS COUNTY FIRE PROTECTION GROUP FOR REVIEW ANDPERMITTING BY THE UNDERGROUND FIRE LINE CONTRACTOR. CIVILREIVEW DOES NOT REVIEW OR APPROVE UNDERGROUND FIRE LINESFOR THE FIRE PROTECTION SYSTEMS.

(#4 MIN.)

REINFORCESTEELSIZE

THIS DOCUMENT IS FOR INTERIM

REVIEW AND NOT INTENDED

FOR CONSTRUCTION,

BIDDING, OR PERMIT

PURPOSES BY:

JOHN D. DOE

TEXAS P.E. XXXXX

DATE: JANUARY 01, 2012

3 XX

XXXXXXX

JOHN D. DOE

1 XX

T.B.P.E. FIRM REGISTRATION #

COMPANY LOGO

ADD YOUR COMPANY LOGO AND

T.B.P.E. FIRM NUMBERALWAYS check w/HCPID for the latest

Express Review Sheet.

THIS is just a go by for how to

set/add your COMPANY Infomation.

AutoCAD SHX Text
I, , A LICENSED PROFESSIONAL ENGINEER IN THE STATE OF TEXAS, DO HEREBY CERTIFY
AutoCAD SHX Text
THAT THE INFORMATION PRESENTED ON THIS SHEET IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE
AutoCAD SHX Text
AND THAT I AM NOT VIOLATING ANY PROVISION OF THE CURRENT TEXAS ENGINEERING PRACTICE ACT AND RULES
AutoCAD SHX Text
CONCERNING THE PRACTICE OF ENGINEERING AND PROFESSIONAL ENGINEERING LICENSURE.
AutoCAD SHX Text
THE COMPLETED PROJECT CONSISTS OF DRAWING SHEETS THRU .
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
ANY VIOLATIONS WILL BE FORWARDED TO THE HARRIS COUNTY DISTRICT ATTORNEY'S OFFICE FOR PROSECUTION.
AutoCAD SHX Text
PUBLIC
AutoCAD SHX Text
PUBLIC & PRIVATE
AutoCAD SHX Text
FIRM PANEL(S) FOR PROPERTY:
AutoCAD SHX Text
FIRM PANEL(S) DATE:
AutoCAD SHX Text
STATUS OF PROPERTY ON MAP
AutoCAD SHX Text
ENTIRELY LOCATED IN UNSHADED ZONE "X"
AutoCAD SHX Text
LOCATED PARTIALLY OR ENTIRELY IN ANY "A" ZONE OR SHADED ZONE "X",
AutoCAD SHX Text
ELEVATION INFORMATION
AutoCAD SHX Text
BENCHMARK USED
AutoCAD SHX Text
DESCRIPTION OF BENCHMARK INCLUDING ELEVATION, DATUM AND
AutoCAD SHX Text
%%uII. FLOOD PLAIN DETERMINATION BASED ON GROUND ELEVATION
AutoCAD SHX Text
PROPERTY LIES ENTIRELY ABOVE THE BASE FLOOD LEVEL
AutoCAD SHX Text
PROPERTY LIES PARTIALLY OR ENTIRELY BELOW THE BASE FLOOD
AutoCAD SHX Text
AND IN SHADED ZONE "X"
AutoCAD SHX Text
LEVEL
AutoCAD SHX Text
YEAR OF ADJUSTMENT
AutoCAD SHX Text
HARRIS COUNTY FLOODPLAIN REFERENCE MARK
AutoCAD SHX Text
HARRIS-GALVESTON COASTAL SUBSIDENCE DISTRICT
AutoCAD SHX Text
RE-DEVELOPMENT AREA (AMOUNT INCREASED IMPERVIOUS AREA): ______
AutoCAD SHX Text
NEW DEVELOPMENT AREA:
AutoCAD SHX Text
%%UI. PROPOSED DRAINAGE AREA
AutoCAD SHX Text
NEW AREA______X____=______ACRE FEET
AutoCAD SHX Text
%%UII. DETENTION VOLUME
AutoCAD SHX Text
PROPOSED DETENTION VOLUME = ________ ACRE FEET
AutoCAD SHX Text
%%uIII. OUTFALL
AutoCAD SHX Text
EXISTING H.C. STORM SEWER
AutoCAD SHX Text
H.C. ROADSIDE DITCH
AutoCAD SHX Text
OTHER
AutoCAD SHX Text
%%uIV. PUMPED DETENTION FACILITIES
AutoCAD SHX Text
%%UII. SUBDIVISION PROJECTS
AutoCAD SHX Text
PRIVATE WATER & WASTE WATER SYSTEMS
AutoCAD SHX Text
UTILITY DISTRICT/MUNICIPALITY NAME:
AutoCAD SHX Text
PUBLIC WATER & SANITARY
AutoCAD SHX Text
INDIVIDUAL WATER WELL & OSSF
AutoCAD SHX Text
PRIVATE WATER WELL & SEPTIC SYSTEM
AutoCAD SHX Text
PRIVATE WATER WELL & PUBLIC SANITARY
AutoCAD SHX Text
NONE
AutoCAD SHX Text
RECORDED PLAT / REPLAT
AutoCAD SHX Text
NO LEFT / RIGHT TURN LANE IS PROPOSED
AutoCAD SHX Text
LEFT / RIGHT TURN LANE IS SHOWN ON SHEET
AutoCAD SHX Text
NO MEDIAN CUT OR RELOCATION IS PROPOSED
AutoCAD SHX Text
MEDIAN MODIFICATIONS ARE SHOWN ON SHEET
AutoCAD SHX Text
SHEET NUMBER ___ OF ___
AutoCAD SHX Text
HARRIS COUNTY PROJECT NO.
AutoCAD SHX Text
PROPOSED PLAT / REPLAT
AutoCAD SHX Text
WAS ACCEPTED BY THE FOLLOWING GROUPS FOR THE PURPOSES LISTED BELOW:
AutoCAD SHX Text
INTERPOSE NO OBJECTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
AS TO STORM WATER QUALITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
THE PROJECT WAS REVIEWED, HOWEVER, THIS DOES NOT MEAN THE ENTIRE PROJECT, INCLUDING ALL SUPPORTING DATA
AutoCAD SHX Text
AND CALCULATIONS HAVE BEEN COMPLETELY CHECKED AND VERIFIED. THESE DRAWINGS ARE SIGNED, DATED AND SEALED
AutoCAD SHX Text
BY A PROFESSIONAL ENGINEER LICENSED TO PRACTICE IN THE STATE OF TEXAS, WHICH THEREFORE CONVEYS THE ENGINEER'S
AutoCAD SHX Text
RESPONSIBILITY AND ACCOUNTABILITY. THIS DOES NOT RELIEVE ANY PARTY FROM COMPLYING WITH APPROPRIATE FEDERAL, STATE
AutoCAD SHX Text
AND LOCAL ENVIRONMENTAL RULES, LAWS, AND REGULATIONS AND ANY OTHER LEGALLY ADOPTED REGULATION OR ORDINANCE
AutoCAD SHX Text
UNTIL SUCH SIGNATURES ARE OBTAINED. THESE SIGNATURES ARE VALID FOR A MAXIMUM OF TWO YEARS.
AutoCAD SHX Text
I. LEGAL DESCRIPTION
AutoCAD SHX Text
%%uI. GENERAL INFORMATION
AutoCAD SHX Text
BENCHMARK (FOR COASTAL AREAS)
AutoCAD SHX Text
DELINEATE FLOODPLAIN BOUNDARY ON CONSTRUCTION DRAWINGS
AutoCAD SHX Text
II. HARRIS COUNTY STANDARD DRIVEWAY DETAIL APPEARS ON SHEET ____
AutoCAD SHX Text
I. NUMBER OF DRIVEWAY APPROACHES PROPOSED INCLUDE WIDENING OR
AutoCAD SHX Text
%%UI. MEDIAN CUTS
AutoCAD SHX Text
%%UII. LEFT / RIGHT TURN LANE
AutoCAD SHX Text
%%UIII. TRAFFIC CONTROL PLAN
AutoCAD SHX Text
TRAFFIC CONTROL SHOWN ON SHEET
AutoCAD SHX Text
NO WORK IN THE RIGHT OF WAY IS PROPOSED THAT
AutoCAD SHX Text
WOULD INTERFERE WITH TRAFFIC FLOW
AutoCAD SHX Text
DETENTION POND (APPROVED H.C. PRJ NO.): _____________
AutoCAD SHX Text
HCFCD DRAINAGE DITCH UNIT NO.: _____________
AutoCAD SHX Text
%%UIII. DRAINAGE SYSTEM OUTFALLS DIRECTLY TO EXISTING
AutoCAD SHX Text
%%UII. DESIGN METHOD USED
AutoCAD SHX Text
CITY OF HOUSTON ____ YEAR FREQUENCY
AutoCAD SHX Text
OTHER: _______________________
AutoCAD SHX Text
%%UI. PROPOSED DRAINAGE SYSTEM TYPE
AutoCAD SHX Text
STORM SEWER
AutoCAD SHX Text
ROADSIDE DITCH
AutoCAD SHX Text
%%UV. DETENTION PROVIDED BY
AutoCAD SHX Text
DETENTION BASIN IS PART THIS PLAN SET. SERVICE AREA MAP IS ON SHEET ___
AutoCAD SHX Text
H.C. ROADSIDE DITCH (ROAD NAME): ____________
AutoCAD SHX Text
%%uV. FLOW RESTRICTOR SIZE
AutoCAD SHX Text
DETENTION REQUIRED
AutoCAD SHX Text
OUTFALL TO
AutoCAD SHX Text
OUTFALL PIPE SIZE:
AutoCAD SHX Text
RESTRICTOR PIPE SIZE:
AutoCAD SHX Text
VOLUME THAT GRAVITY FLOWS: ACRE FEET
AutoCAD SHX Text
VOLUME THAT IS PUMPED: ACRE FEET
AutoCAD SHX Text
ENTRANCE VELOCITY INTO ROADSIDE DITCH
AutoCAD SHX Text
PUMP SPECIFICATIONS AND AUTOMATIC SHUTOFF PLAN FOR ROADSIDE DITCH
AutoCAD SHX Text
OR STORM SEWER:
AutoCAD SHX Text
& STORM SEWER OUTFALLS APPEAR ON SHEET
AutoCAD SHX Text
ROADSIDE DITCH OUTFALL:
AutoCAD SHX Text
ALLOWABLE OUTFALL RATE: 0.0027 x _____ LF Frontage = _____ (CFS)
AutoCAD SHX Text
PROPOSED OUTFALL RATE: ____ (CFS), CALCULATIONS PROVIDED ON SHEET ___
AutoCAD SHX Text
STORM SEWER OUTFALL
AutoCAD SHX Text
CAPACITY ALLOCATED TO TRACT FROM D. A. MAP: _______ (CFS)
AutoCAD SHX Text
FROM DRAINAGE AREA MAP DATED:
AutoCAD SHX Text
PREPARED BY:
AutoCAD SHX Text
ACTUAL OUTFALL RATE: ____ (CFS), CALCULATIONS PROVIDED ON SHEET ___
AutoCAD SHX Text
%%uIII. FLOODPLAIN STORAGE SUMMARY
AutoCAD SHX Text
%%UI. DETENTION SUMMARY
AutoCAD SHX Text
A. TOTAL VOLUME OF MATERIAL PROPOSED TO BE MOVED OR PLACED WITHIN
AutoCAD SHX Text
%%UII. HCFCD STANDARD NOTES%%U: SEE SHEET _____ OF THESE PLANS.
AutoCAD SHX Text
%%UIII. HCFCD STANDARD DETAILS%%U: SEE SHEET _____ OF THESE PLANS.
AutoCAD SHX Text
%%uIV. REFER TO PLAN SHEETS %%U %%u %%U FOR EXISTING AND PROPOSED RIGHT
AutoCAD SHX Text
OF WAY DELINEATION AND COMPLETE RECORDING INFORMATION TO INCLUDE
AutoCAD SHX Text
CLERK'S FILE NUMBERS, TYPE OF ESTATE (e.g., DRAINAGE EASEMENT,
AutoCAD SHX Text
FEE STRIP, ETC.) AND GRANTEE (e.g. COH, HCFCD, PUBLIC, TXDOT, ETC.)
AutoCAD SHX Text
I. COMPLETE ONLY IF HCFCD OR HARRIS COUNTY IS REQUIRING DETENTION.
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
II. COMPLETE ONLY IF PROJECT HAS WITHIN IT OR IS IMMEDIATELY ADJACENT TO AN EXISTING OR
AutoCAD SHX Text
PROPOSED HCFCD MAINTAINED CHANNEL OR DETENTION BASIN.
AutoCAD SHX Text
III. COMPLETE ONLY IF PROJECT INCLUDES NEW OUTFALL, BACKSLOPE INTERCEPTOR OR OTHER
AutoCAD SHX Text
RELATED WORK WITHIN AN EXISTING OR PROPOSED HCFCD MAINTAINED CHANNEL OR DETENTION BASIN.
AutoCAD SHX Text
IV. COMPLETE ONLY OF PROJECT HAS WITHIN OR IMMEDIATELY ADJACENT TO IT AN EXISTING
AutoCAD SHX Text
OR PROPOSED PUBLIC DRAINAGE CHANNEL OR DETENTION BASIN.
AutoCAD SHX Text
(APPLIES ONLY TO PORTION OF LAND LOCATED WITHIN
AutoCAD SHX Text
FLOODPLAIN AS DELINEATED BY FIRM PANEL).
AutoCAD SHX Text
THE FIRM DELINEATED FLOODPLAIN (FILL, BASE, CONCRETE, ASPHALT, ETC.):
AutoCAD SHX Text
i.e., BELOW ELEVATION
AutoCAD SHX Text
(2001 ADJ.)
AutoCAD SHX Text
CUBIC YARDS
AutoCAD SHX Text
DELINEATED FLOODPLAIN:
AutoCAD SHX Text
B. TOTAL VOLUME OF MATERIAL PROPOSED TO BE REMOVED FROM THE FIRM
AutoCAD SHX Text
(2001 ADJ.)
AutoCAD SHX Text
CUBIC YARDS
AutoCAD SHX Text
i.e., BELOW ELEVATION
AutoCAD SHX Text
AS TO LOCATION OF ITEMS IN COUNTY RIGHT OF WAY
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SITE REMOVED FROM FLOODPLAIN BY LOMR, LOMR-F, LOMA
AutoCAD SHX Text
CASE NO.__________ REVISED FLOODPLAIN IS SHOWN ON SHEET____
AutoCAD SHX Text
4" x 12" CURBING PROPOSED EXCEPT AT MEDIANS AND ISLANDS
AutoCAD SHX Text
STANDARD 6" CURBING PROPOSED
AutoCAD SHX Text
II.
AutoCAD SHX Text
I. ISLANDS AND MEDIANS REQUIRE STANDARD 6" CURBING
AutoCAD SHX Text
VERIFIED BY:
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
INTERPOSE NO OBJECTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
BY
AutoCAD SHX Text
FOR ITEMS LOCATED OUTSIDE OF HCFCD RIGHT-OF-WAY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR ITEMS LOCATED WITHIN EXISTING HCFCD RIGHT-OF-WAY
AutoCAD SHX Text
BY
AutoCAD SHX Text
FOR ITEMS LOCATED WITHIN PROPOSED HCFCD RIGHT-OF-WAY
AutoCAD SHX Text
ADDITIONAL COMMENTS:
AutoCAD SHX Text
RAINFALL EVENT PROBABILITY
AutoCAD SHX Text
PRE-DEVELOPED PEAK
AutoCAD SHX Text
POST-DEVELOPED PEAK
AutoCAD SHX Text
DETENTION BASIN
AutoCAD SHX Text
MAXIMUM WATER
AutoCAD SHX Text
RUNOFF (CFS)
AutoCAD SHX Text
RUNOFF (CFS)
AutoCAD SHX Text
PEAK OUTFLOW (CFS)
AutoCAD SHX Text
SURFACE ELEVATION
AutoCAD SHX Text
PEAK STORAGE
AutoCAD SHX Text
VOLUME (AC-FT)
AutoCAD SHX Text
STORAGE RATE
AutoCAD SHX Text
(AC-FT PER AC)
AutoCAD SHX Text
10%%% EXCEEDANCE (10-YEAR)
AutoCAD SHX Text
1% EXCEEDANCE (100-YEAR)
AutoCAD SHX Text
DETENTION BASIN DRAINAGE AREA = _____ ACRES
AutoCAD SHX Text
STORMWATER DETENTION BASIN ROUTING TABLE
AutoCAD SHX Text
ADDITIONAL CRITERIA FOR PUMPED DETENTION BASINS:
AutoCAD SHX Text
VOLUME OF PUMPED 1% EXCEEDANCE STORAGE VOLUME = _____AC-FT _____ % OF TOTAL VOLUME
AutoCAD SHX Text
MAXIMUM DESIGN OUTFLOW VELOCITY INTO HCFCD CHANNEL = __________FT./SEC.
AutoCAD SHX Text
DRAIN TIME FOR BASIN = __________ HOURS BASED ON ___________________________________ HEAD CONDITIONS.
AutoCAD SHX Text
STORMWATER DRAINAGE DESIGN REPORT
AutoCAD SHX Text
REPORT TITLE ___________________________________________________________________________________
AutoCAD SHX Text
REPORT DATE _____________________ ENGINEERING FIRM _____________________________________________
AutoCAD SHX Text
DATE OF ACCEPTANCE BY HCFCD OR FLOODPLAIN ADMINISTRATOR_________________ HCFCD PROJECT #______________
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AS TO PAVING AND/OR DRAINAGE ONLY
AutoCAD SHX Text
BY
AutoCAD SHX Text
%%UIV. H.C. OUTFALL CALCULATIONS
AutoCAD SHX Text
%%UIV. TRAFFIC SIGNAL
AutoCAD SHX Text
LOMR REQUIRED
AutoCAD SHX Text
%%UIV.
AutoCAD SHX Text
PROJECT NAME:
AutoCAD SHX Text
NO TRAFFIC SIGNAL IS EXISTING / PROPOSED
AutoCAD SHX Text
PROPOSED STORM SEWER IS SUBMERGED (AGREEMENT MUST BE PROVIDED).
AutoCAD SHX Text
STATIC W.S.E. @ OUTFALL IS _________________.
AutoCAD SHX Text
REQUIRED AND SHOWN ON SHEET(S) %%U
AutoCAD SHX Text
NOT REQUIRED DUE TO %%U
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
VERSION 17.0 JANUARY 1, 2019
AutoCAD SHX Text
%%UIV. HCAD ACCOUNT NOS. (ALL)
AutoCAD SHX Text
A. ACREAGE:
AutoCAD SHX Text
A. SUBDIVISION PLAT
AutoCAD SHX Text
EXISTING TRAFFIC SIGNAL DEVICES (T.C. BOXES AND LOOPS)
AutoCAD SHX Text
SHOWN ON SHEET
AutoCAD SHX Text
%%UV. TRAFFIC IMPACT ANALYSIS
AutoCAD SHX Text
NO TRAFFIC IMPACT ANALYSIS IS REQUIRED
AutoCAD SHX Text
TRAFFIC IMPACT ANALYSIS HAS BEEN APPROVED ON DATE:_______
AutoCAD SHX Text
PROPOSED TRAFFIC SIGNAL (BY OTHERS)
AutoCAD SHX Text
.55 (CHANNEL)
AutoCAD SHX Text
.65 (STM SWR)
AutoCAD SHX Text
1.00 (RD. DITCH)
AutoCAD SHX Text
OTHER:
AutoCAD SHX Text
ADDITIONAL COMMENTS:
AutoCAD SHX Text
RELATED TO LAND DEVELOPMENT. IF THE CITY SIGNATURES ARE REQUIRED BY ORDINANCE, COUNTY PERMITS WILL NOT BE ISSUED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
R E V I S I O N S
AutoCAD SHX Text
H.C. APPROVED DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PRIVATE
AutoCAD SHX Text
%%UI. SWPPP: CONSTRUCTION MEASURES. %%U(Complete for ALL projects)
AutoCAD SHX Text
OTHER(S):
AutoCAD SHX Text
DISTURBS >1AC. SITE PLAN & DETAILS ON SHEET(S)
AutoCAD SHX Text
%%UII. APPLICABILITY FOR PERMANENT FEATURES. (must be completed on all projects)
AutoCAD SHX Text
%%UIII. PERMANENT SWQ FEATURES.%%U (COMPLETE IF NOT EXEMPT)
AutoCAD SHX Text
DETAILS AND CALCULATIONS APPEAR ON SHEET(S)
AutoCAD SHX Text
VEGETATIVE CONTROLS USED: (FILTER STRIP, GRASSY SWALE, URBAN FORESTRY)
AutoCAD SHX Text
PROJECT'S DRAINAGE TIES DIRECTLY INTO AN EXISTING DRAINAGE SYSTEM PRIOR TO
AutoCAD SHX Text
SITE PLAN ON SHEET(S)
AutoCAD SHX Text
POND STRUCTURE USED (WET, DRY, WETLANDS) DETAILS AND CALCULATIONS
AutoCAD SHX Text
APPEAR ON SHEET(S)
AutoCAD SHX Text
PROJECT DOES NOT MEET THE DEFINITION OF SIGNIFICANT REDEVELOPMENT (Part A,
AutoCAD SHX Text
STORMWATER QUALITY PERMIT REQUIREMENT IS COVERED BY AN EXISTING SWQMP WITHIN
AutoCAD SHX Text
PROJECT TITLE:
AutoCAD SHX Text
HYDRODYNAMIC TYPE SEPARATOR MODEL:
AutoCAD SHX Text
OUTFALL
AutoCAD SHX Text
UTILITY CROSSING
AutoCAD SHX Text
ROADWAY BRIDGE / CULVERT CROSSING
AutoCAD SHX Text
%%UI. TYPE OF WORK TO BE PERFORMED IN CHANNEL
AutoCAD SHX Text
US ARMY CORPS OF ENGINEERS INDIVIDUAL PERMITS
AutoCAD SHX Text
FILL ACTIVITY
AutoCAD SHX Text
REHABILITATION OF CHANNEL
AutoCAD SHX Text
MAINTENANCE
AutoCAD SHX Text
TEMPORARY CROSSING
AutoCAD SHX Text
OTHER
AutoCAD SHX Text
%%UII. USACE ENVIRONMENTAL PERMIT
AutoCAD SHX Text
PERMIT NUMBER(S) ______________
AutoCAD SHX Text
US ARMY CORPS ENGINEERS NATIONWIDE
AutoCAD SHX Text
OTHER
AutoCAD SHX Text
EXPLAIN:
AutoCAD SHX Text
NO PERMITS REQUIRED
AutoCAD SHX Text
%%UIII. REFERENCE / BASIS OF DETERMINATION
AutoCAD SHX Text
ENVIRONMENTAL CONSULTANT REPORT
AutoCAD SHX Text
REPORT TITLE ______________________________
AutoCAD SHX Text
REPORT DATE ______________________________
AutoCAD SHX Text
BY _____________________________________
AutoCAD SHX Text
OTHER ___________________________________
AutoCAD SHX Text
I. - III. REQUIRED ON PROJECTS WITH WORK IN A HCFCD CHANNEL.
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
REQUIRED AND SHOWN ON SHEET(S) _________________
AutoCAD SHX Text
NOT REQUIRED
AutoCAD SHX Text
PLEASE REFERENCE SECTION 17 OF THE FLOOD CONTROL DISTRICT
AutoCAD SHX Text
POLICY, CRITERIA, AND PROCEDURE MANUAL FOR MORE INFORMATION.
AutoCAD SHX Text
CRITICAL FACILITY
AutoCAD SHX Text
STORM WATER QUALITY
AutoCAD SHX Text
CIVIL SITE WORK (PHASE II PERMIT CLASS I (non-floodplain))
AutoCAD SHX Text
CIVIL SITE WORK (PHASE II PERMIT CLASS II (floodplain))
AutoCAD SHX Text
SUBDIVISION INFRASTRUCTURE PHASE II (NO. OF LOTS = _____ )
AutoCAD SHX Text
BUILDING PERMITS (NO. OF BUILDINGS = _____ )
AutoCAD SHX Text
DRIVEWAY WITH CULVERT _____ CURB AND GUTTER _____
AutoCAD SHX Text
SEPTIC (EXISTING)
AutoCAD SHX Text
NOTICE OF DETENTION AFFIDAVIT REQUIRED
AutoCAD SHX Text
(DRAINAGE LAYOUT PG. NO._____)
AutoCAD SHX Text
A PERMIT IS REQUIRED FOR EACH SCOPE OF WORK ON SITE.
AutoCAD SHX Text
A NOTIFICATION IS REQUIRED FOR EACH SCOPE OF WORK IN HC OR HCFCD ROW.
AutoCAD SHX Text
REFER TO %%Uwww.eng.hctx.net/permits%%U FOR EACH SCOPE OF WORK IN HC OR IN HCFCD ROW.
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
SURVEY & ABSTRACT:
AutoCAD SHX Text
C. ADJACENT ROADS:
AutoCAD SHX Text
II. PLATTING
AutoCAD SHX Text
CONFORMING SUBDIVISION
AutoCAD SHX Text
PLAT NAME:
AutoCAD SHX Text
B. STREETS PROPOSED
AutoCAD SHX Text
ETJ, CITY OF HOUSTON
AutoCAD SHX Text
NO ETJ
AutoCAD SHX Text
ETJ, CITY OF
AutoCAD SHX Text
CITY OF
AutoCAD SHX Text
III. JURISDICTIONS
AutoCAD SHX Text
B. SUBDIVISION:
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
(BASE FLOOD LEVEL_____)
AutoCAD SHX Text
%%UV. UNOBSTRUCTED VISIBILITY EASEMENT (U.V.E.)
AutoCAD SHX Text
REQUIRED AND SHOWN ON SHEET(S) %%U
AutoCAD SHX Text
NOT REQUIRED
AutoCAD SHX Text
MAX BASIN DRAIN TIME (100-YR EVENT) = _____ HOURS
AutoCAD SHX Text
SEPTIC (PROPOSED)
AutoCAD SHX Text
H.C. SEPTIC PERMIT/REQUEST NO. ______
AutoCAD SHX Text
P.E. INITIAL
AutoCAD SHX Text
LEFT TURN LANE ____________________________________
AutoCAD SHX Text
UTILITY WORK ____________________________________
AutoCAD SHX Text
OTHER CONSTRUCTION _________________________________
AutoCAD SHX Text
C. FILL AREA & VOLUME CALCULATIONS ARE SHOWN ON SHEET
AutoCAD SHX Text
CLOMR REQUIRED
AutoCAD SHX Text
ADDRESS:
AutoCAD SHX Text
APPROVED H.C. PROJECT NO.:
AutoCAD SHX Text
(FOR H.C. PUBLIC R.O.W. ONLY)
AutoCAD SHX Text
DOES PROPERTY HAVE EXISTING AND/OR PROPOSED UTILITIES?
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
PUBLIC WATER & PRIVATE SEPTIC SYSTEM
AutoCAD SHX Text
%%UI. COMMERCIAL PROJECTS
AutoCAD SHX Text
H.C. WASTE WATER REVIEWER APPROVAL
AutoCAD SHX Text
NAME & DATE: ____________________
AutoCAD SHX Text
REVIEWER COMMENTS: _____________________
AutoCAD SHX Text
PRIVATE WATER & INDIVIDUAL OSSF
AutoCAD SHX Text
UTILITY DISTRICT/MUNICIPALITY NAME: ______________
AutoCAD SHX Text
DETENTION VOLUME PROVIDED BY EXISTING DETENTION POND
AutoCAD SHX Text
APPROVED H.C. PROJECT NO.: ________
AutoCAD SHX Text
DETENTION POND SERVICE AREA MAP IS PROVIDED ON SHEET ____
AutoCAD SHX Text
KEY MAP PAGE
AutoCAD SHX Text
LOW IMPACT DEVELOPMENT (LID)
AutoCAD SHX Text
LOW IMPACT DEVELOPMENT (LID)
AutoCAD SHX Text
WIDTH
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
CULVERT?
AutoCAD SHX Text
CULVERT
AutoCAD SHX Text
X-STREET
AutoCAD SHX Text
DIST. TO
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
NEAREST
AutoCAD SHX Text
X-STREET
AutoCAD SHX Text
DRWY
AutoCAD SHX Text
REPAVING EXISTING DRIVEWAYS AS WELL AS NEW DRIVEWAYS
AutoCAD SHX Text
5
AutoCAD SHX Text
PROPOSED DETENTION VOLUME CALCULATIONS ARE SHOWN ON SHEET ______
AutoCAD SHX Text
AFTER PLANS HAVE BEEN APPROVED BY HARRIS COUNTY.
AutoCAD SHX Text
NOTE: REVISION BLOCK IS TO BE USED ONLY FOR CHANGES MADE
AutoCAD SHX Text
PLAN TITLE: _______________________________
AutoCAD SHX Text
HCPID PROJECT NO.: _________
AutoCAD SHX Text
MUD MAINTENANCE AGREEMENT REQUIRED
AutoCAD SHX Text
H.C. STORM SEWER (APPROVED H.C. PRJ NO.): ____________
AutoCAD SHX Text
ROADSIDE DITCH OUTFALL:
AutoCAD SHX Text
ALLOWABLE OUTFALL RATE: 0.0027 x _____ LF Frontage = _____ (CFS)
AutoCAD SHX Text
PROPOSED OUTFALL RATE: ____ (CFS), CALCULATIONS PROVIDED ON SHEET ___
AutoCAD SHX Text
STORM SEWER OUTFALL
AutoCAD SHX Text
CAPACITY ALLOCATED TO TRACT FROM D. A. MAP: _______ (CFS)
AutoCAD SHX Text
FROM DRAINAGE AREA MAP DATED:
AutoCAD SHX Text
PREPARED BY:
AutoCAD SHX Text
ACTUAL OUTFALL RATE: ____ (CFS), CALCULATIONS PROVIDED ON SHEET ___
AutoCAD SHX Text
APPROVED H.C. PROJECT NO.:
AutoCAD SHX Text
REGIONAL DETENTION BASIN SYSTEM (APPROVED H.C. PRJ NO.): ________
AutoCAD SHX Text
Sec. 2.39 of Regulations of Harris County, Texas for Stormwater Quality Management)
AutoCAD SHX Text
PROJECT IS ON A PARCEL (A COMMON PLAN OF DEVELOPMENT) LESS THAN 5 ACRES.
AutoCAD SHX Text
A. ARE CURB RAMPS THAT CONNECT TO PUBLIC STREETS PROPOSED IN THIS SET OF PLANS? [ ] YES [ ] NO
AutoCAD SHX Text
(FOR VERIFICATION: PROVIDE ORIGINAL DRAINAGE AREA MAP INCLUDING CALCULATIONS)
AutoCAD SHX Text
PROJECT'S SWQ REQUIREMENTS FALL WITHIN THE JURISDICTION OF:
AutoCAD SHX Text
HARRIS COUNTY PROJECT NO. & SWQ PERMIT NO.
AutoCAD SHX Text
EXEMPT NEW DEVELOPMENT:
AutoCAD SHX Text
EXEMPT REDEVELOPMENT:
AutoCAD SHX Text
EXEMPT REDEVELOPMENT:
AutoCAD SHX Text
EXEMPT GRANDFATHERED:
AutoCAD SHX Text
%%UGENERAL:
AutoCAD SHX Text
DETENTION POND MAINTAINED BY: _____________
AutoCAD SHX Text
HCFCD ROW NOTIFICATION PERMIT REQUIRED
AutoCAD SHX Text
DISTURBS <1AC. N/A
AutoCAD SHX Text
%%USTORMWATER QUALITY MANAGEMENT PLAN:
AutoCAD SHX Text
(must be verified with plat)
AutoCAD SHX Text
OCTOBER 1, 2001.
AutoCAD SHX Text
NON-CONFORMING SUBDIVISION
AutoCAD SHX Text
PARTIALLY NON-CONFORMING SUBDIVISION
AutoCAD SHX Text
GEOTECHNICAL INVESTIGATION REPORT
AutoCAD SHX Text
REPORT TITLE ___________________________________________________________________________________
AutoCAD SHX Text
REPORT DATE _____________________ ENGINEERING FIRM _____________________________________________
AutoCAD SHX Text
DATE OF ACCEPTANCE BY HCFCD _________________ HCFCD PROJECT #______________
AutoCAD SHX Text
STORMWATER DETENTION FOR THE PROPOSED WORK CONTAINED IN THESE PLANS IS PROVIDED BY OTHER PLANS:
AutoCAD SHX Text
PLAN TITLE ____________________________________________________________________________________________
AutoCAD SHX Text
ENGINEERING FIRM _____________________________ DATE SIGNED BY HCFCD __________________ HCFCD PROJECT # ________
AutoCAD SHX Text
50%%% EXCEEDANCE (2-YEAR)
AutoCAD SHX Text
PEN TABLE: _SWSP 22x34 PDF.ctb_SWSP 22x34 PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\General Sheets\G-03 Express Review Sheet - Version 17.0.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\General Sheets\G-03 Express Review Sheet - Version 17.0.dwg
AutoCAD SHX Text
PLOTTED: 10/9/2019 12:19 PM10/9/2019 12:19 PM
Page 4: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

UTILITY NOTESGENERAL CONSTRUCTION NOTES

WATER MAIN CONSTRUCTION NOTES

CONTRACTOR WORK ZONE NOTES

SANITARY SEWER CONSTRUCTION NOTES

1. THERE WILL BE NO SEPARATE PAYMENT FOR WORK SHOWN ON THESE PLANS UNLESS OTHERWISE SPECIFICALLY

ESTABLISHED IN BID SECTION OF CONTRACT DOCUMENTS. INCLUDE COST OF THIS WORK IN CONTRACT UNIT PRICE

FOR ITEMS OF WHICH THIS WORK IS A COMPONENT OR INCIDENTAL TO.

2. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF EXISTING FACILITIES PRIOR TO CONSTRUCTION OF

PROPOSED FACILITIES. ANY DAMAGE TO EXISTING FACILITIES INCURRED AS A RESULT OF CONSTRUCTION

OPERATIONS WILL BE REPAIRED AT CONTRACTOR'S EXPENSE.

3. CONTRACTOR SHALL REMAIN FULLY RESPONSIBLE FOR ANY AND ALL DAMAGE TO EXISTING PUBLIC OR PRIVATE

UTILITY LINES, INCLUDING BUT NOT LIMITED TO WATER MAINS, WASTEWATER COLLECTION SYSTEMS, AND STORM

SEWERS, DURING CONSTRUCTION.

4. REMOVE EXISTING PLUGS AND CONNECT PROPOSED UTILITY LINES AS INDICATED ON PLANS.

5. VERIFY LOCATION OF UNDERGROUND UTILITIES AND NOTIFY THE FOLLOWING AGENCIES 48-HRS PRIOR TO

EXCAVATING NEAR EXISTING FACILITIES:

A) TEXAS 811 AT (800) 245-4545

B) LONE STAR NOTIFICATION CENTER AT (800) 669-8344

C) TEXAS EXCAVATION SAFETY SYSTEM INC. AT (800) 344-8377.

6. COMPLY WITH ALL FEDERAL, STATE, AND LOCAL LAWS AND ALL REGULATIONS OF UTILITY COMPANIES

CONCERNING SAFETY AND HEALTH PRACTICES.

7. INCLUDE PRICE OF ALL BEDDING AND BACKFILL OF TYPE REQUIRED IN PRICE BID PER LINEAR FOOT OF PIPE.

8. ALL SEWER TRENCHES UNDER OR WITHIN 1-FT OF PROPOSED AND/OR FUTURE PAVEMENT OR CURB SHALL BE

BACKFILLED WITH 1-1/2 SACKS OF CEMENT PER CUBIC YARD CEMENT-STABILIZED SAND TO A POINT 1-FT BELOW

PAVEMENT SUBGRADE. REMAINING BACKFILL SHALL BE MADE WITH COMPACTED SUITABLE

MATERIAL PER SPECIFICATIONS.

9. OWNER WILL FURNISH INITIAL LABORATORY TESTS. SUBSEQUENT TESTING DUE TO FAILED TESTS SHALL BE AT

CONTRACTOR'S EXPENSE. COPY OF ALL TEST RESULTS SHALL BE SUBMITTED TO ENGINEER.

10. DAILY REMOVE ALL MUD, DIRT, AND DEBRIS DEPOSITED OR DROPPED ON EXISTING PAVEMENT DUE TO

CONSTRUCTION ACTIVITY. MATERIAL THAT IS HAZARDOUS TO TRAFFIC SHALL BE REMOVED IMMEDIATELY.

11. ALL TRAFFIC CONTROL AND WARNING SIGNS SHALL BE IN ACCORDANCE WITH THE TEXAS MANUAL ON UNIFORM

TRAFFIC CONTROL DEVICES.

12. WHEN TRENCH CONDITION WARRANTS USE OF DEWATERING SYSTEMS, THEIR USE SHALL BE REQUESTED BY

CONTRACTOR AND APPROVED BY OWNER.

13. THESE PLANS DO NOT EXTEND OR INCLUDE DESIGNS OR SYSTEMS PERTAINING TO THE SAFETY OF THE

CONTRACTOR OR ITS EMPLOYEES, AGENTS, OR REPRESENTATIVES IN THE PERFORMANCE OF THE WORK. SEAL OF

THE REGISTERED PROFESSIONAL ENGINEER(S) HEREON DOES NOT EXTEND TO ANY SUCH SAFETY SYSTEMS THAT

MAY NOW OR HEREAFTER BE INCORPORATED IN THESE PLANS. CONTRACTOR SHALL INDEPENDENTLY PREPARE

AND/OR OBTAIN THE APPROPRIATE SAFETY SYSTEMS.

14. PROTECT ALL TREES DURING CONSTRUCTION. NO TREES SHALL BE REMOVED WITHOUT OWNER'S PERMISSION,

UNLESS OTHERWISE SPECIFIED IN PLANS.

15. GIVE NOTICE TO ALL AUTHORIZED INSPECTORS, SUPERINTENDENTS, OR PERSONS IN CHARGE OF PRIVATE AND

PUBLIC UTILITIES OR RAILROADS AFFECTED BY OPERATIONS PRIOR TO COMMENCEMENT OF WORK. OBTAIN

ALL NECESSARY CONSTRUCTION PERMITS PRIOR TO STARTING CONSTRUCTION.

16. OBTAIN ALL PERMITS REQUIRED BY REGULATION OF HARRIS COUNTY, TEXAS FOR FLOOD PLAIN MANAGEMENT

PRIOR TO STARTING CONSTRUCTION.

17. OBTAIN ALL PERMITS REQUIRED BY HARRIS COUNTY, TEXAS PRIOR TO STARTING CONSTRUCTION OF UTILITIES

AND/OR CULVERTS WITHIN HARRIS COUNTY ROAD RIGHTS-OF-WAY, IF APPLICABLE.

18. NOTIFY HARRIS COUNTY ENGINEERING DEPARTMENT BY WRITTEN NOTIFICATION 48-HRS IN ADVANCE OF

STARTING CONSTRUCTION, FOLLOWED BY TELEPHONE NOTIFICATION AT (713) 316-3561 24-HRS IN ADVANCE OF

STARTING CONSTRUCTION. A COPY OF WRITTEN NOTIFICATION SHALL BE SENT TO ENGINEER.

19. ALL DISTURBED AREAS OR AREAS AFFECTED BY CONSTRUCTION IN BOTH PRIVATE AND PUBLIC PROPERTIES

SHALL BE CLEANED AND RETURNED TO EXISTING OR BETTER CONDITIONS. DISTURBED VEGETATED AREAS SHALL

BE HYDRO-MULCHED UNLESS OTHERWISE NOTED ON THE PLANS. DISTURBED SWALES AND OTHER DRAINAGE

FACILITIES SHALL BE RESTORED AND REMAIN FUNCTIONAL AFTER CONSTRUCTION. DISTURBED AREAS WITHIN

HCFCD RIGHTS-OF-WAY AND/OR EASEMENTS SHALL BE FULLY RESTORED IN ACCORDANCE WITH APPLICABLE

HCFCD STANDARD CONSTRUCTION SPECIFICATIONS.

20. ALL OPEN TRENCHES, TUNNEL SHAFTS, OR OTHER EXCAVATIONS SHALL BE SECURED IN ACCORDANCE WITH

OSHA REQUIREMENTS.

21. ALL OPEN CUTS ON PAVEMENTS SHALL BE REPLACED AND REPAIRED PER DETAILS. STEEL PLATES SHALL BE

USED AS WARRANTED TO PROVIDE A CONTINUOUS TRAFFIC FLOW AFTER WORKING HOURS.

22. ALL HIKE AND BIKE TRAILS SHALL BE REPLACED IF DAMAGED OR REMOVED DURING CONSTRUCTION.

23. RESTORE ALL SPRINKLER AND/OR IRRIGATION SYSTEMS DISTURBED DURING CONSTRUCTION TO ORIGINAL

CONDITION OR BETTER, NO SEPARATE PAY.

1. MAINTAIN TWO LANES OPEN WHEN WORKING IN BOULEVARD SECTIONS. RESIDENTIAL SECTIONS WILL MAINTAIN

ONE LANE OPEN WITH ADEQUATE SIGNAGE AND/OR FLAGMEN TO FACILITATE USE OF LANE.

2. DRIVEWAY ACCESS SHALL BE MAINTAINED OPEN AFTER WORKING HOURS. A MINIMUM OF ONE DRIVEWAY ACCESS

SHALL BE MAINTAINED OPEN AT ALL TIMES TO COMMERCIAL, APARTMENT, AND/OR NON-RESIDENTIAL

DEVELOPMENTS. SCHOOL DRIVEWAYS SHALL BE MAINTAINED OPEN WHERE PRACTICAL WHEN SCHOOL IS SESSION.

IN THE EVENT THAT SCHOOL DRIVEWAYS WILL BE IMPACTED IN ANY WAY, COORDINATE ALL WORK WITH SCHOOL.

3. THE LENGTH OF WORK ZONE SHALL BE MINIMIZED WITHIN HARRIS COUNTY RIGHTS-OF-WAY AND/OR EASEMENTS.

THERE SHALL NOT BE MORE THAN 200-FT OF TRENCH OPEN AT ANY ONE TIME. CONSTRUCTION ZONE SHALL BE A

ROLLING CONSTRUCTION ZONE WITH APPROPRIATE TRANSITIONS ON EACH END.

4. LANES SHALL NOT BE CLOSED AT A SIGNALIZED INTERSECTION UNLESS APPROVED BY HARRIS COUNTY ENGINEER.

AN APPROPRIATE TRANSITION AS DEFINED IN TRAFFIC CONTROL PLAN SHALL BE PROVIDED AT SIGNALIZED

INTERSECTIONS.

5. SEPARATION DISTANCES FOR INSTALLATION OF POTABLE WATER DISTRIBUTION LINES AND WASTEWATER

COLLECTION LINES, WASTEWATER FORCE MAINS AND OTHER CONVEYANCES/APPURTENANCES IDENTIFIED AS

POTENTIAL SOURCES OF CONTAMINATION MUST CONFORM TO TEXAS COMMISSION ON ENVIRONMENTAL QUALITY

RULES AND REGULATIONS.

6. TEMPORARY EPOXY-GLUED PAVEMENT BUTTONS OR "CONSTRUCTION GRADE" TAPE PAVEMENT MARKERS SHALL

BE USED ON PERMANENT PAVEMENT TO REMAIN IN-PLACE TO ELIMINATE GRINDING AND SCARRING OF SURFACE.

7. CARE SHALL BE TAKEN TO PROVIDE FOR TEMPORARY PEDESTRIAN TRAFFIC AND CROSSING AT AREAS SUCH AS

SCHOOLS, PARKS, AND SHOPPING AREAS.

8. WORK SHALL BE CONFINED TO WEST HARRIS COUNTY REGIONAL WATER AUTHORITY WATER MAIN OR

CONSTRUCTION EASEMENTS OR TO AREAS IDENTIFIED ON PLANS.

1. ALL NEWLY INSTALLED PIPES, COATINGS, AND RELATED PRODUCTS SHALL CONFORM TO ANSI/NSF STANDARDS

AND MUST BE CERTIFIED BY AN ORGANIZATION ACCREDITED BY ANSI.

2. UNLESS OTHERWISE INDICATED ON THE PLANS, ALL WATER MAIN TRENCHES SHALL BE BACKFILLED WITH

BANK-RUN SAND TO A POINT 1-FT OVER TOP OF PIPE. REMAINING BACKFILL SHALL BE MADE WITH COMPACTED

SUITABLE MATERIAL PER SPECIFICATIONS. ALL TRENCHES WITHIN HCFCD RIGHTS-OF-WAY AND/OR

EASEMENTS SHALL BE BACKFILLED AND RESTORED IN ACCORDANCE WITH APPLICABLE HCFCD STANDARD

CONSTRUCTION SPECIFICATIONS.

3. CONTACT DISTRICT OPERATOR PRIOR TO MAKING ANY CONNECTION(S) TO EXISTING WATER MAINS AND/OR

ANYTIME A VALVE ON AN EXISTING WATER MAIN IS TO BE OPENED OR CLOSED.

4. ALLOW A MINIMUM OF 1-FT VERTICAL AND 4-FT HORIZONTAL CLEARANCE BETWEEN PROPOSED WATER MAINS AND

OTHER EXISTING OR PROPOSED UTILITIES. WATER MAINS CROSSING STORM SEWERS SHALL HAVE A MINIMUM

OF 2-FT VERTICAL CLEARANCE.

5. WHEN A WATER MAIN IS PLACED NEAR A SANITARY SEWER MANHOLE, IT SHALL HAVE A MINIMUM OF 9-FT WALL TO

WALL SEPARATION. WHERE A WATER MAIN PARALLELS A SANITARY SEWER, 9-FT SEPARATION SHALL BE MAINTAINED

IN ALL DIRECTIONS. IF THE 9-FT SEPARATION CANNOT BE ACHIEVED, BOTH SEWER PIPE AND JOINTS SHALL HAVE A

MINIMUM PRESSURE RATING OF 150-PSI AND MANHOLES SHALL BE WATER TIGHT. VERTICAL SEPARATION SHALL BE A

MINIMUM OF 2-FT BETWEEN OUTSIDE DIAMETERS AND HORIZONTAL SEPARATION SHALL BE A MINIMUM OF 4-FT

BETWEEN OUTSIDE DIAMETERS.

6. ALL WATER MAINS WITHIN DEDICATED EASEMENTS SHALL HAVE A MINIMUM 6-FT OF COVER FROM NATURAL

GROUND. ALL WATER MAINS WITHIN RIGHTS-OF-WAY WITH IMPROVED ROADWAY SHALL HAVE A MINIMUM 6-FT OF

COVER FROM EXISTING OR PROPOSED TOP OF CURB (TOC). ALL WATER MAINS WITHIN RIGHTS-OF-WAY WITH

UNIMPROVED ROADWAY SHALL HAVE A MINIMUM 8-FT OF COVER FROM NATURAL GROUND.

7. UNLESS OTHERWISE SHOWN ON PLANS, CONSTRUCT WATER MAINS WITH ONE JOINT OF PIPE BEYOND PROPOSED

VALVES AND PLUGS FOR FUTURE LINES.

8. VALVES SHALL BE EQUIPPED WITH OPERATING NUT EXTENSIONS TO WITHIN 4-FT OF NATURAL GROUND IN

ACCORDANCE WITH SPECIFICATIONS.

9. INSTALL RESTRAINED JOINTS AS NECESSARY AND AS SHOWN TO ENSURE INTEGRITY OF THE WATER MAIN AT TEST

PRESSURE. THIS WORK IS INCIDENTAL TO WATER MAIN INSTALLATION, NO SEPARATE PAY.

10. ALL WATER MAINS SHALL BE INSTALLED BY OPEN CUT METHODS UNLESS OTHERWISE INDICATED ON PLANS OR

DIRECTED BY ENGINEER.

11. PROVIDE DETECTABLE WARNING TAPE FOR NON-METALLIC PIPING, PER SPECIFICATIONS.

12. WHEN CROSSING AN EXISTING STORM SEWER USING OPEN CUT METHODS, WATER MAIN TRENCH ZONE, AS

DEFINED IN THE SPECIFICATIONS AND DETAILS, SHALL BE BACKFILLED FOR 3-FT TO 5-FT EITHER SIDE OF STORM

SEWER WITH CEMENT STABILIZED SAND TO SPRING LINE OF STORM SEWER.

13. ALL WATER MAINS 24-IN AND LARGER IN DIAMETER SHALL BE PRE-STRESSED CONCRETE CYLINDER PIPE (AWWA

C301), BAR-WRAPPED CONCRETE CYLINDER PIPE (AWWA C303), STEEL PIPE, OR DUCTILE IRON PIPE, UNLESS

OTHERWISE INDICATED ON PLANS.

14. MECHANICAL RESTRAINED JOINTS TO BE USED IN PLACE OF WELDED RESTRAINED JOINTS IF DUCTILE IRON PIPE

(DIP) IS USED.

1. GRAVITY SANITARY SEWERS AND FORCE MAINS SHALL BE INSTALLED IN ACCORDANCE WITH CITY OF HOUSTON

STANDARD SPECIFICATIONS. ONLY PRE-CAST CONCRETE MANHOLES WILL BE ALLOWED.

2. SANITARY SEWERS CROSSING WATER MAINS SHALL BE DUCTILE IRON PIPE WITH A MINIMUM 150-PSI RATED WATER

PRESSURE (AWWA C151), DOUBLE WRAPPED IN 8-MIL POLYETHYLENE OR POLYVINYL CHLORIDE PIPE DR 18

(AWWA C900 OR C905).

3. INTERIOR LINING FOR DUCTILE IRON PIPE SANITARY SEWER SHALL BE PROVIDED IN ACCORDANCE WITH PIPE

MANUFACTURER'S RECOMMENDATIONS AND CONFORM TO REQUIREMENTS OF EITHER ASTM D1248, ASTM D1653, OR

ASTM D16 TYPE V. MINIMUM LINING THICKNESS TO BE 40-MILS, REGARDLESS OF COATING RECOMMENDED BY

MANUFACTURER. NO CEMENT MORTAR LINING OR BITUMINOUS LINING WILL BE ALLOWED.

4. UNLESS OTHERWISE NOTED ON PLANS, WHERE SANITARY SEWER MANHOLES ARE LOCATED WITHIN EASEMENTS,

RIM ELEVATION SHALL BE SET 3-IN ABOVE NATURAL GROUND AND/OR FINISHED GRADE. WHERE SANITARY SEWER

MANHOLES ARE LOCATED WITHIN 100-YEAR FLOOD PLAIN, RIM ELEVATION SHALL BE SET 12-IN ABOVE 100 YEAR

FLOOD ELEVATION OR SHALL BE SEALED.

5. PROVIDE ADEQUATE THRUST BLOCKING AT ALL FORCE MAIN BENDS TO WITHSTAND PRESSURE TEST.

6. INSTALL OVER FORCE MAIN LINES "TERRA TAPE" OR APPROVED EQUAL. TAPE TO BE CONTINUOUSLY LABELED

"NON POTABLE WATER". SUCH WORK IS INCIDENTAL TO FORCE MAIN INSTALLATION, REPAIR, OR REPLACEMENT, NO

SEPARATE PAY.

7. ALL SEMI-RIGID SEWER PIPE SHALL BE TESTED FOR DEFLECTION. TESTING SHALL BE PERFORMED 30-DAYS AFTER

BACKFILL OPERATIONS ARE COMPLETED AND PRIOR TO OTHER TESTING OF SEWER SYSTEMS. TEST FOR

DEFLECTION BY PULLING A HAND LINE WITH AN ATTACHED MANDREL DEVICE THROUGH PIPE (NO MECHANICAL

PULLING DEVICE ALLOWED). MANDREL TO HAVE AN OUTSIDE DIAMETER EQUAL TO 95% OF THE NOMINAL DIAMETER

OF PIPE BEING TESTED. MANDREL TO BE MANUFACTURED WITH A MINIMUM OF SEVEN (7) RUNNERS,

WITH EACH RUNNER BEING A MINIMUM OF 5-IN LONG. ANY PIPE NOT MEETING TEST REQUIREMENTS SHALL BE

REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. PAYMENT FOR THIS WORK TO BE INCLUDED IN UNIT PRICE

BID PER LINEAR FOOT OF SEWER IN APPROPRIATE SIZE.

STORM SEWER CONSTRUCTION NOTES

1. ALL STORM SEWERS AND LEADS SHALL BE REINFORCED CONCRETE PIPE (RCP), CLASS III (ASTM C76), WITH

RUBBER GASKET JOINTS (ASTM C443), 24-IN DIAMETER MINIMUM, UNLESS OTHERWISE NOTED ON PLANS.

2. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. ANY DRAINAGE DITCH OR

STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO THE SATISFACTION OF THE OWNING

AUTHORITY. ALL CONSTRUCTION STORM RUNOFF SHALL COMPLY WITH THE STORM WATER MANAGEMENT

HANDBOOK FOR CONSTRUCTION ACTIVITIES AS PREPARED BY HARRIS COUNTY, HCFCD, AND THE CITY OF HOUSTON

AND SHALL BE IN COMPLIANCE WITH THE NPDES REQUIREMENTS.

STANDARD HARRIS COUNTY NOTES FOR PLANS

STORM SEWER QUALITY PRE-CONSTRUCTION

INSPECTION REQUIREMENTS

1. CONTACT THE HARRIS COUNTY STORM WATER QUALITY PERMITTING SECTION AT (713) 956-3000 FOR A

PRE-CONSTRUCTION INSPECTION PRIOR TO COMMENCING ANY CLEARING OR CONSTRUCTION ACTIVITIES AT THE

PROJECT SITE.

1. AUTHORIZATION NOTICE ISSUED BY HARRIS COUNTY PUBLIC INFRASTRUCTURE ENGINEERING DEPARTMENT

PERMIT OFFICE REQUIRED PRIOR TO CONSTRUCTION OF UTILITIES OR LEFT TURN LANES WITHIN HARRIS COUNTY

RIGHTS-OF-WAY. CONTACT HARRIS COUNTY PERMIT OFFICE (713) 956-3000.

2. AUTHORIZATION NOTICE ISSUED BY HARRIS COUNTY PUBLIC INFRASTRUCTURE ENGINEERING DEPARTMENT

PERMIT OFFICE REQUIRED PRIOR TO CONSTRUCTION WITHIN HARRIS COUNTY FLOOD CONTROL RIGHT-OF-WAY.

CONTACT HARRIS COUNTY PERMIT OFFICE (713) 956-3000.

3. VENT PIPES WITHIN HARRIS COUNTY RIGHTS-OF-WAY SHALL BE BREAKAWAY, PER DETAILS, UNLESS OTHERWISE

INDICATED ON DRAWINGS AND APPROVED BY HARRIS COUNTY PUBLIC INFRASTRUCTURE ENGINEERING

DEPARTMENT.

4. CONTRACTOR IS FULLY RESPONSIBLE FOR OBTAINING ALL PERMITS REQUIRED BY THE "REGULATIONS OF HARRIS

COUNTY, TEXAS FOR FLOOD PLAIN MANAGEMENT" PRIOR TO START OF CONSTRUCTION.

STANDARD HCFCD NOTES FOR PLANS

1. NOTIFY HARRIS COUNTY FLOOD CONTROL DISTRICT (HCFCD), PROPERTY MANAGEMENT DEPARTMENT IN WRITING

AT LEAST 48-HOURS PRIOR TO CONSTRUCTION. SUBMIT THE HCFCD 48-HOUR PRE-CONSTRUCTION NOTIFICATION

FORM AND A COPY OF THE APPROVED CONSTRUCTION DRAWINGS TO HCFCD, 9900 NORTHWEST FREEWAY,

HOUSTON, TEXAS 77092, ATTN: PROPERTY MANAGEMENT DEPARTMENT.

2. ENGINEER SHALL SUBMIT CERTIFICATION LETTER AND RECORD DRAWINGS TO THE HCFCD, PROPERTY

MANAGEMENT DEPARTMENT, REQUESTING INSPECTION OF ITEMS CONSTRUCTED IN HCFCD RIGHT-OF-WAY. PRIOR

TO REQUESTING INSPECTION, THE DRAINAGE RIGHT-OF-WAY AND/OR EASEMENTS SHALL BE STAKED AND FLAGGED.

3. PROTECT, MAINTAIN, AND RESTORE EXISTING BACKSLOPE DRAINAGE SYSTEMS.

4. BACKSLOPE SWALE AND INTERCEPTOR STRUCTURE ELEVATIONS AND LOCATIONS SHOWN ON PLANS ARE

APPROXIMATE. FINAL ELEVATIONS AND LOCATIONS SHALL BE VERIFIED BY THE ENGINEER PRIOR TO INSTALLATION.

5. ESTABLISH TURF GRASS ON ALL DISTURBED AREAS WITHIN THE CHANNEL OR DETENTION RIGHT-OF-WAY, EXCEPT

THE CHANNEL BOTTOM AND WHERE STRUCTURAL EROSION MEASURES ARE USED. MINIMUM ACCEPTANCE CRITERIA

ARE 75% COVERAGE OF LIVE BERMUDA GRASS AND NO EROSION OF RILLS DEEPER THAN 4-IN.

6. BACKFILL ALL TRENCHES AND BORE PITS IN ACCORDANCE WITH THE SPECIFICATION, SECTION 02317-EXCAVATI0N

AND BACKFILL FOR UTILITIES.

7. EXCAVATE CHANNEL FLOWLINE TO DESIGN ELEVATION AS SHOWN ON PLANS AND DOWNSTREAM, AS NECESSARY,

TO ENSURE NO WATER IN STORM SEWER DURING "DRY" CONDITIONS.

8. MAINTAIN FLOW IN CHANNEL DURING CONSTRUCTION AND RESTORE CHANNEL TO ORIGINAL CONDITION.

9. REMOVE ALL EXCAVATED MATERIAL FROM THE HCFCD OR DRAINAGE RIGHT-OF-WAY. NO FILL IS TO BE PLACED

WITHIN A DESIGNATED FLOOD PLAIN AREA WITHOUT FIRST OBTAINING A FILL PERMIT FROM THE APPROPRIATE

JURISDICTIONAL AUTHORITY.

10. OBTAIN AND COMPLY WITH ALL APPLICABLE CITY, COUNTY, STATE, AND FEDERAL PERMITS AND APPROVALS,

WITH ASSISTANCE FROM ENGINEER, IF NECESSARY.

THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY DAMAGES CAUSED BY HIS FAILURE TO EXACTLY LOCATE AND

PRESERVE THESE UNDERGROUND FACILITIES.

WARNING: OVERHEAD ELECTRICAL LINES

OVERHEAD LINES MAY EXIST ON THE PROPERTY. THE LOCATION OF OVERHEAD LINES HAS NOT BEEN SHOWN ON

THESE DRAWINGS AS THE LINES ARE CLEARLY VISIBLE, BUT YOU SHOULD LOCATE THEM PRIOR TO BEGINNING

ANY CONSTRUCTION. TEXAS LAW, SECTION 752, HEALTH & SAFETY CODE FORBIDS ACTIVITIES THAT OCCUR IN

CLOSE PROXIMITY TO HIGH VOLTAGE LINES, SPECIFICALLY:

PARTIES RESPONSIBLE FOR THE WORK, INCLUDING CONTRACTORS, ARE LEGALLY RESPONSIBLE FOR THE SAFETY

OF CONSTRUCTION WORKERS UNDER THIS LAW. THIS LAW CARRIES BOTH CRIMINAL AND CIVIL LIABILITY.

TO ARRANGE FOR LINES TO BE TURNED OFF OR REMOVED CALL CENTERPOINT ENERGY AT (713) 207-2222.

· WHEN CENTERPOINT ENERGY PIPE LINE MARKINGS ARE NOT VISIBLE, CALL (713)

967-8037 (7:00 A.M. TO 4:30 P.M.) FOR STATUS OF LINE LOCATION REQUEST BEFORE

EXCAVATION BEGINS.

· WHEN EXCAVATING WITHIN 18-IN OF THE INDICATED LOCATION OF CENTERPOINT

ENERGY FACILITIES, ALL EXCAVATION MUST BE ACCOMPLISHED USING

NON-MECHANIZED EXCAVATION PROCEDURES.

· WHEN CENTERPOINT ENERGY FACILITIES ARE EXPOSED, SUFFICIENT SUPPORT

MUST BE PROVIDED TO THE FACILITIES TO PREVENT EXCESSIVE STRESS ON THE

PIPING.

CAUTION: UNDERGROUND GAS FACILITIES

LOCATIONS OF CENTERPOINT ENERGY MAIN LINES (TO INCLUDE CENTERPOINT ENERGY, INTRASTATE PIPELINE,

LLC. WHERE APPLICABLE) ARE SHOWN IN AN APPROXIMATE LOCATION ONLY. SERVICE LINES ARE USUALLY NOT

SHOWN. OUR SIGNATURE ON THESE PLANS ONLY INDICATES THAT OUR FACILITIES ARE SHOWN IN

APPROXIMATE LOCATION. IT DOES NOT IMPLY THAT A CONFLICT ANALYSIS HAS BEEN MADE. THE CONTRACTOR

SHALL CONTACT THE UTILITY COORDINATING COMMITTEE AT (713) 223-4567 OR 1-800-669-8344 A MINIMUM OF 48

HOURS PRIOR TO CONSTRUCTION TO HAVE MAIN AND SERVICE LINES FIELD LOCATED.

· ANY ACTIVITY WHERE PERSON OR THINGS MAY COME WITHIN 6-FT OF LIVE

OVERHEAD HIGH VOLTAGE LINES; AND

· OPERATING A CRANE, DERRICK, POWER SHOVEL, DRILLING RIG, PILE DRIVER,

HOISTING EQUIPMENT, OR SIMILAR APPARATUS WITHIN 10-FT OF LIVE OVERHEAD

HIGH VOLTAGE LINES.

AT&T TEXAS/SWBT FACILITIES

DISTRICT NAME:

OPERATOR COMPANY:

OPERATOR CONTACT:

CONTACT PHONE #:

NATURAL GAS

PIPELINE COMPANY

NOTES

1. THE LOCATIONS OF AT&T TEXAS/SBWT FACILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE

CONTRACTOR SHALL DETERMINE THE EXACT LOCATION BEFORE COMMENCING WORK. HE AGREES TO BE

FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY THIS FAILURE TO

EXACTLY LOCATE AND PRESERVE THESE UNDERGROUND UTILITIES.

2. THE CONTRACTOR SHALL CALL 1-800-344-8377 (TEXAS 811) A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION

TO HAVE UNDERGROUND LINES FIELD LOCATED.

3. WHEN EXCAVATING WITHIN 18-IN OF THE INDICATED LOCATION OF AT&T TEXAS/SWBT FACILITIES, ALL

EXCAVATIONS MUST BE ACCOMPLISHED USING NON-MECHANIZED EXCAVATION PROCEDURES.

WHEN BORING, THE CONTRACTOR SHALL EXPOSE THE AT&T TEXAS/SWBT FACILITIES.

4. WHEN AT&T TEXAS/SBWT FACILITIES ARE EXPOSED, THE CONTRACTOR WILL PROVIDE SUPPORT TO PREVENT

DAMAGE TO THE CONDUIT DUCTS OR CABLES. WHEN EXCAVATING NEAR TELEPHONE POLES THE CONTRACTOR

SHALL BRACE THE POLE FOR SUPPORT.

5. THE PRESENCE OR ABSENCE OF AT&T TEXAS/SBWT UNDERGROUND CONDUIT FACILITIES OR BURIED CABLE

FACILITIES SHOWN ON THESE PLANS DOES NOT MEAN THAT THERE ARE NO DIRECT BURIED CABLES OR

6. PLEASE CONTACT THE AT&T TEXAS DAMAGE PREVENTION MANAGER MR. ROOSEVELT LEE JR. AT (713) 567-4552

OR EMAIL HIM AT [email protected], IF THERE ARE QUESTIONS ABOUT BORING OR EXCAVATING NEAR OUR

AT&T TEXAS/SWBT FACILITIES.

OTHER CABLES IN CONDUIT IN THE AREA.

TEXAS WATER DEVELOPMENT BOARD NOTES:

1. AS PER AN AGREEMENT WITH THE UNITED STATES ARMY CORPS OF ENGINEERS (PROJECT NO. SWG-2016-00933)

THE AUTHORITY AGREES TO USE TRENCHLESS CONSTRUCTION METHODS AT ALL STREAM CROSSINGS;

2. IN ACCORDANCE WITH THE NATIONAL FLOOD INSURANCE PROGRAM, PRIOR TO CONSTRUCTION WITHIN ANY

GIVEN FLOODPLAIN, A FLOODPLAIN PERMIT MUST BE OBTAINED FROM THE LOCAL FLOODPLAIN ADMINISTRATOR;

3. STANDARD EMERGENCY CONDITION FOR THE DISCOVERY OF CULTURAL RESOURCES; AND

4. STANDARD EMERGENCY CONDITION FOR THE DISCOVERY OF THREATENED AND ENDANGERED SPECIES.

GENERAL

CONSTRUCTION NOTES

XX

HORIZ

VERT

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

G-04

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\04-General\G-04 General Notes.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\04-General\G-04 General Notes.dwg
AutoCAD SHX Text
PLOTTED: 5/27/2020 2:25 PM5/27/2020 2:25 PM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 5: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

3"

30

"1

5"

3"44"

24-

1

2

"

THE WATER WE CONSERVE

TODAY CAN SERVE US

TOMORROW ...

A JOINT PROJECT OF THE

24-

1

2

"

4'-0

"4

'-0

"

4'-0

"

8'-0"

5'-0"

8"

8"

4x4 POSTS

2-

1

2

" BLUE LETTERS

w/1-

1

2

" SPACING

WHITE BACKGROUND

3" WHITE LETTERS

w/1-

1

2

" SPACING ON

A BLUE BACKGROUND

2" WHITE LETTERS

1

2

" REFLECTIVE RED BORDER

FRONT VIEWBACK VIEW

CONSTRUCTION PROJECT SIGN

GROUND LEVEL

41"

1"

SCALE:1"=1'-0"

INFORMATION: 1-844-638-7977

1

--

E-mail: [email protected]

Website: www.SurfaceWaterSupplyProject.com

AND

NAME OFPROJECT

NOTES:

1. CONTRACTOR TO PROVIDE 2 SIGNS.

NO SEPARATE PAY.

2. SIGNS TO BE INSTALLED AT

LOCATIONS AS DIRECTED BY

ENGINEER.

6"1' 1'0

1"=1'-0"

2'

D-01

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

PROJECT SIGN

DETAIL

XX

HORIZ

VERT

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-01 Project Sign.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-01 Project Sign.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 9:45 AM5/28/2020 9:45 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 6: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

t

NOTES:

1. ALL BUTT STRAP JOINTS SHALL BE WELDED ON THE EXTERIOR AND INTERIOR BOTH ENDS.

2. BUTT STRAPS TO BE FURNISHED IN TWO PIECES AND SHIPPED LOOSE FOR FIELD WELDING.

BUTT STRAPS TO INCLUDE TABS TO ACCEPT ALL-THREAD FOR BOLTED CONNECTION TO

FACILITATE FIELD LINE-UP AND WELDING.

3. 12" MAXIMUM LENGTH OF TYPICAL BUTT STRAP FOR FIELD CLOSING SECTION. (SEE

SPECIFICATIONS).

4. SEE JOINT DETAILS FOR TYPICAL LAP WELD ON POLYURETHANE COATED STEEL PIPE AND FOR

ADDITIONAL INFORMATION ON COATINGS, LININGS AND OTHER REQUIREMENTS.

5. "t" INDICATES THE THICKNESS OF THE STEEL PIPE AT THE SECTION WHERE USED.

6. DRILL AND TAP 4-

1

4

" DIA. HOLES EQUALLY SPACED FOR AIR-SOAP TEST. BEFORE WELDING,

DRILL AND TAP HOLES. PLUG WELD HOLES AFTER SUCCESSFUL COMPLETION OF JOINT TEST.

7. FIELD APPLY HEAT SHRINK SLEEVE WITH A MINIMUM OVERLAP OF 4" OVER POLYURETHANE

COATING.

1

1

4

" TYP

2" MIN

7" MAX3" MIN

WF 2" x 4" NO. 13 GAUGE

Scale: NTS.

POLYURETHANE COATED STEEL PIPE

4

Scale: NTS.

LOOSE BUTT STRAP

5

Scale: NTS.

LONGITUDINAL WELD - BUTT STRAP

6

P

I

P

E

O

D

+

1

/

8

"

3

7

°

3

0

'

1/8"

1/16"

1

1

4

"

1

1

4

"

1/8"

1/4" STD PIPE TAP

& PLUG (4 HOLES)

BUTT STRAP

"

T

"

T

H

K

O

F

P

I

P

E

W

A

L

L

SHOP APPLIED

MORTAR LINING

MORTAR FILL

WITH WIRE FABRIC

TAP BOTH PIPE ENDS FOR AIR

TEST. SEE NOTE 6

HEAT SHRINK SLEEVE

t

t

BUTT STRAP JOINTS (4 LOCATIONS)

BACKGOUGE

t

Scale: NTS.

POLYURETHANE COATED STEEL PIPE

2

DOUBLE WELD LAP JOINT DETAIL

6" MIN.

FLAT BELL

2" MIN. LAP

NOTES:

1. 2" MIN FROM BELL TANGENT TO WELD.

2. HOLD BACK SHOP APPLIED MORTAR LINING MIN. 6 INCHES ON BELL END AND 2 INCHES ON

SPIGOT END.

3. HOLD BACK SHOP APPLIED POLYURETHANE COATING MIN. 5 INCHES ON BELL END AND 4 INCHES

ON SPIGOT END.

4. DRILL AND TAP 4-

1

4

" DIA. HOLES EQUALLY SPACED FOR AIR-SOAP TEST. BEFORE WELDING,

DRILL AND TAP HOLES. PLUG WELD HOLES AFTER SUCCESSFUL COMPLETION OF JOINT TEST.

5. FIELD APPLY HEAT SHRINK SLEEVE WITH A MINIMUM OVERLAP OF 4" OVER POLYURETHANE

COATING.

6. "t" INDICATES THE THICKNESS OF THE STEEL PIPE AT THE SECTION WHERE USED.

10" MAX

SHOP APPLIED

MORTAR LINING

(SEE NOTE 2)

SHOP APPLIED

POLYURETHANE

COATING AS

SPECIFIED

(SEE NOTE 3)

HEAT SHRINK SLEEVE

(SEE NOTE 5)

1/16" CHAMFER, TYP

MOTAR IN FIELD

AFTER COMPLETION

OF BACKFILL

SHOP APPLIED

MORTAR LINING

(SEE NOTE 2)

SHOP APPLIED

POLYURETHANE

COATING AS SPECIFIED

(SEE NOTE 3)

SACRIFICIAL HEAT SHRINK SLEEVE

(IF REQUIRED BY SLEEVE SYSTEM

MANUFACTURER)

t

t

t

Scale: NTS.

POLYURETHANE COATED STEEL PIPE

1

SINGLE WELD LAP JOINT DETAIL

6" MIN.

FLAT BELL

2" MIN. LAP

NOTES:

1. 2" MIN FROM BELL TANGENT TO WELD.

2. HOLD BACK SHOP APPLIED MORTAR LINING MIN. 6 INCHES ON BELL END AND 2 INCHES ON SPIGOT

END.

3. HOLD BACK SHOP APPLIED POLYURETHANE COATING MIN. 5 INCHES ON BELL END AND 4 INCHES ON

SPIGOT END.

4. FIELD APPLY HEAT SHRINK SLEEVE WITH A MINIMUM OVERLAP OF 4" OVER POLYURETHANE COATING.

5. "t" INDICATES THE THICKNESS OF THE STEEL PIPE AT THE SECTION WHERE USED.

10" MAX

SHOP APPLIED

MORTAR LINING

(SEE NOTE 2)

SHOP APPLIED

POLYURETHANE

COATING AS

SPECIFIED

(SEE NOTE 3)

HEAT SHRINK SLEEVE

(SEE NOTE 4)

MOTAR IN FIELD

AFTER COMPLETION

OF BACKFILL

SHOP APPLIED

MORTAR LINING

(SEE NOTE 2)

SHOP APPLIED

POLYURETHANE

COATING AS SPECIFIED

(SEE NOTE 3)

SACRIFICIAL HEAT SHRINK SLEEVE

(IF REQUIRED BY SLEEVE SYSTEM

MANUFACTURER)

t

t

2" MIN

1/4"

1/4" x 2" BACKING PLATE

SHOP APPLIED

MORTAR LINING

FIELD WELD PER

SPECIFICATIONS

PIPE I.D.

MORTAR IN FIELD AFTER

COMPLETION OF BACKFILL

Scale: NTS.

POLYURETHANE COATED STEEL PIPE

3

TAP FOR AIR TEST

(SEE NOTE 4)

PIPE WALL

FILL MATERIAL

AS SPECIFIED

PER

AWWA L200

PER

AWWA L200

HEAT SHRINK SLEEVE

WELDED BUTT STRAP JOINT DETAIL

t

t

SHOP APPLIED

POLYURETHANE

COATING AS

SPECIFIED

t

BUTT WELD JOINT DETAIL

SACRIFICIAL HEAT SHRINK

SLEEVE (IF REQUIRED BY

SLEEVE SYSTEM

MANUFACTURER)

SACRIFICIAL HEAT SHRINK SLEEVE

(IF REQUIRED BY SLEEVE SYSTEM

MANUFACTURER)

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

D-02

STEEL PIPE DETAILS

(SHEET 1 OF 2)

XX

HORIZ

VERT

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-02 Steel Pipe Details Sheet 1 Of 2.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-02 Steel Pipe Details Sheet 1 Of 2.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 7:46 AM5/28/2020 7:46 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 7: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

Scale: N.T.S

INTERNAL ELLIPTICAL DISHED HEAD PLUG REMOVAL

2

Scale: N.T.S

POLYURETHANE COATED STEEL PIPE

1

COATING PER SPECIFICATIONS

6" FLG. OUTLET W/ AWWA C207

RING AND GATE VALVE

CEMENT MORTAR LINING

PER SPECIFICATIONS

SEE VIEW "A"

Scale: N.T.S

VIEW A

-

CEMENT MORTAR LINING

PER SPECIFICATIONS

t

t

t

t

t

t

CEMENT MORTAR LINING

PER SPECIFICATIONS

INTERNAL ELLIPTICAL

DISHED HEAD PLUG

(CUT AND REMOVE

AFTER TEST)

1/4" M

AX

FLAME CUT IN FIELD

PLACE 2"x4" No. 13 GAUGE WIRE

FABRIC IN OPENING AND PACK WITH

NON-SHRINK GROUT AFTER TEST

PLUG IS REMOVED

NOTES:

1. DISHED HEAD PLUG TO BE INSTALLED AT

LOCATION WHERE AIR CAN BE EXPELLED

THROUGH AIR VALVE OR ACCESS MANHOLE

DURING FILLING.

2. DISHED HEAD PLUGS SHALL BE CAPABLE OF

WITHSTANDING THE HYDROSTATIC TEST

PRESSURE FROM EITHER SIDE, WITH THE

OPPOSITE SIDE EMPTY OF WATER

3. t = STEEL PIPE WALL THICKNESS AND SIZE OF

FILLET ATTACHMENT WELD.

NOTE: USE CAUTION WHEN REMOVING BULK HEADS. ALL GOUGES AND SURFACE

DEFECTS SHALL BE REPAIRED AS DIRECTED BY ENGINEER.

NOTES:

1. PASS THROUGH FOR WELD LEADS MAY BE SPACED NO CLOSER THAN 500' AND NO

CLOSER THAN 500' FROM AIR VALVE OR ACCESS MANHOLE OUTLETS.

2. PASS-THROUGH TO BE DESIGNED PER AWWA M-11.

3. ROLLED PLATE SHALL BE CENTERED OVER PASS-THROUGH OUTLET AND BE A MINIMUM

OF

1

2

" THICK OR EQUAL TO PIPE WALL THICKNESS, WHICHEVER IS GREATER.

t = 0.1875"

OUTLET ID = 7.00" (STEEL)

OUTLET OD = 7.25" (STEEL)

SHOP APPLIED

MORTAR LINING

t

8"X8" ROLLED PLATE

TO MATCH PIPE O.D.

Scale: NTS.

6" PASS-THROUGH FOR WELD LEADS

3

6"Ø

OPENING

POLYURETHANE COATING

AS SPECIFIED

STEEL PIPE

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

t

t

24" x 24"

POLYURETHANE PATCH

t

MORTAR IN FIELD

INTERNAL ELLIPICAL DISHED HEAD PLUG DETAIL

D-03

STEEL PIPE DETAILS

(SHEET 2 OF 2)

XX

HORIZ

VERT

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-03 Steel Pipe Details Sheet 2 Of 2.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-03 Steel Pipe Details Sheet 2 Of 2.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 8:56 AM5/28/2020 8:56 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 8: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

TRENCH WIDTH = W

TYPICAL TRENCH SECTION OPTION A

1

SCALE: NTS.

CO

VE

R V

AR

IE

S

P

I

P

E

O

.

D

.

6"

TOP OF NATURAL GROUND

5'-0" M

IN

.

24" MIN

30" MAX

24" MIN

30" MAX

EMBEDMENT MATERIAL COMPACTED

TO 95% STD PROCTOR DENSITY

(SEE SPECIFICATIONS)

TRENCH WIDTH = W

FLOWABLE FILL ENCASEMENT OPTION B

2

SCALE: NTS.

CO

VE

R V

AR

IE

S

P

I

P

E

O

.

D

.

PIP

E Z

ON

E

TOP OF NATURAL GROUND

TR

EN

CH

Z

ON

E

5'-0" M

IN

.

12" MIN

24" MAX

12" MIN

24" MAX

SANDBAGS,

SEE NOTE 8

FLOWABLE FILL ENCASEMENT

FILL FROM DRY BOTTOM

EXCAVATION TO 0.7X OD OF PIPE

12"

MIN

EXCAVATION & BACKFILL DETAIL

3

SCALE: NTS.

FILTER FABRIC (FOR WET CONDITIONS,

MIN. LAP 12")

BEDDING MATERIAL - DO NOT COMPACT

WET BOTTOM EXCAVATION GRADE

(USE 12" CRUSHED STONE FOR WET

CONDITIONS BELOW BOTTOM OF PIPE.

COMPACT LOWER 6" LAYER ONLY. NO

SAND BELOW PIPE REQUIRED.)

ALTERNATIVE TRENCH SECTION

℄HALF - SECTION

UNDER PAVEMENTS

HALF - SECTION

UNDER OPEN AREAS

BACKFILL

SEE SPEC 02317

TRENCH BOX

SE

E N

OT

E 7

FILTER

FABRIC,

SEE NOTE 6

BACKFILL

SEE SPEC 02317

TRENCH BOX

ALTERNATIVE TRENCH SECTION

PAVEMENT REPAIR

(SEE PAVEMENT

REPAIR NOTES)

1

GENERAL NOTE:

1. BACKFILL TO NATURAL GROUND SURFACE UNLESS OTHERWISE SHOWN

ON PLAN AND PROFILE DRAWINGS

2. SEE TRENCH SAFETY SYSTEM SPECIFICATION FOR MAXIMUM

ALLOWABLE SLOPES AND TRENCH BOX REQUIREMENTS.

3. FOR WET BOTTOM EXCAVATION LIMITS OF CRUSHED STONE, EXTEND AS

SHOWN. PROVIDE FILTER FABRIC AROUND CRUSHED STONE.

4. PIPE EMBEDMENT ZONE MUST BE FILLED AND RECOMPACTED TO

PROPER DENSITIES AFTER MOVING SUPPORT SYSTEM FORWARD

(APPLIES TO DETAILS 1 AND 3) .

5. USE FILTER FABRIC OR POLYETHYLENE WRAP AS A BOND BREAKER

BETWEEN CEMENT STABILIZED SAND AND PIPE.

6. REFER TO SPEC 02317 FOR GEOTEXTILE REQUIREMENTS AROUND

EMBEDMENT.

7. ADJUST HEIGHT OF UNSUPPORTED TRENCH AS NEEDED FOR SAFE

CONDITIONS.

8. PROVIDE SANDBAGS FOR FLOWABLE FILL ENCASEMENT TO SUPPORT

PIPE TO CORRECT GRADE ABOVE TRENCH BOTTOM. USE ONE SUPPORT

5 FEET FROM EACH END AND AT 10 FEET O.C. FOR THE MIDDLE. FOR

PIPE FURNISHED IN 12 FOOT LENGTHS, USE ONE SUPPORT 3 FEET FROM

EACH END.

9. IN WETLAND AREAS WITH OPEN-CUT CONSTRUCTION, STRIP AND

STOCKPILE 6" OF TOPSOIL. RESTORE TOPSOIL AFTER BACKFILLING TO

MATCH PRE-CONSTRUCTION GRADE. SEE PLAN AND PROFILE SHEETS

FOR AREAS WITH DELINEATED WETLANDS.

SE

E N

OT

E 7

℄HALF - SECTION

UNDER PAVEMENTS

HALF - SECTION

UNDER OPEN AREAS

PAVEMENT REPAIR

(SEE PAVEMENT REPAIR NOTES)

6"

6"

1' MIN.

EXCAVATION MAY BE

WIDENED ABOVE THE PIPE

ZONE AT THE CONTRACTOR'S

EXPENSE, SEE NOTE 2

EXCAVATION MAY BE

WIDENED ABOVE THE PIPE

ZONE AT THE CONTRACTOR'S

EXPENSE, SEE NOTE 2

1

PAVEMENT REPAIR

(SEE PAVEMENT REPAIR NOTES)

COMPACT TO 95% STD.

FILTER FABRIC (FOR

WET CONDITIONS, MIN. LAP 12")

HALF - SECTION

UNDER PAVEMENTS

HALF - SECTION

UNDER OPEN AREAS

1' MIN.

(TYP.)

BEDDING MATERIAL - DO NOT COMPACT

WET BOTTOM EXCAVATION GRADE

(USE 12" CRUSHED STONE FOR WET

CONDITIONS BELOW BOTTOM OF PIPE.

COMPACT LOWER 6" LAYER ONLY. NO

SAND BELOW PIPE REQUIRED.).

FILTER

FABRIC,

SEE NOTE 6

6" TOP SOIL

(OPEN AREAS)

SPRING LINE

PIP

E Z

ON

EA

BO

VE

P

IP

E Z

ON

E

E

AR

TH

B

AC

KF

ILL

VA

RIE

S

BACKFILL

SEE SPEC 02317

W

A

T

E

R

L

I

N

E

O

.

D

.

DRY BOTTOM EXCAVATION

CE

ME

NT

S

TA

BILIZ

ED

S

AN

D

(S

EE

S

PE

CS

)

16' A

ND

G

RE

AT

ER

TRENCH BOX

SE

E N

OT

E 7

24" MIN.

30" MAX.

24" MIN.

30" MAX.

EXCAVATION MAY BE

WIDENED ABOVE THE PIPE

ZONE AT THE CONTRACTOR'S

EXPENSE, SEE NOTE 2

ALTERNATIVE TRENCH SECTION

DETAIL 3 APPLICABLE IN THE FOLLOWING AREAS:

- WATER MAIN WITH HEIGHT OF COVER GREATER THAN 16'

- TUNNEL SHAFT LIMITS

- PPCA LIMITS

PAVEMENT REPAIR NOTES:

1. REMOVE AND REPLACE PAVEMENT AS SHOWN IN DRAWINGS.

2. PAVEMENT REPLACEMENT TO BE DONE IN ACCORDANCE WITH COUNTY

OR CITY STANDARDS.

3. NEW CONCRETE PAVEMENTS TO BE SAME THICKNESS AS EXISTING,

UNLESS OTHERWISE DIRECTED BY THE WHCRWA.

4. STREETS OR DRIVEWAYS SHALL BE REPAIRED OR REPLACED USING

HIGH EARLY STRENGTH CONCRETE AS INDICATED ON DRAWINGS,

ACCORDING TO PAVEMENT REPLACEMENT SCHEDULE WHERE

PROVIDED, OR AS DIRECTED BY WHCRWA.

5. ANY REMOVAL AND REPLACEMENT OF PAVEMENT NOT IDENTIFIED ON

THE DRAWINGS SHALL BE COORDINATED WITH THE ENGINEER AND THE

WHCRWA.

6. WHEN CURB IS REMOVED AND REPLACED, INSTALL 1 FOOT STRIP OF

SOD GRASS BEHIND CURB TO PREVENT EROSION UNTIL GRASS IS

ESTABLISHED.

7. ROADWAY EXCAVATION, SITE GRADING, AND HYDROMULCH SEEDING OR

SODDING WITHIN R.O.W. AND/OR LIMITS OF CONSTRUCTION SHALL BE IN

ACCORDANCE WITH CONSTRUCTION SPECIFICATIONS.

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

PIP

E Z

ON

ET

RE

NC

H Z

ON

E

1' MIN

1' MIN

D-04

EXCAVATION BEDDING

AND BACKFILL DETAILS

XX

HORIZ

VERT

6" TOP SOIL

(OPEN AREAS)

(FOR WATER MAIN WITH HEIGHT OF COVER GREATER THAN 16')

6" TOP SOIL

(OPEN AREAS)

AutoCAD SHX Text
12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-04 Excavation Bedding And Backfill Details.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-04 Excavation Bedding And Backfill Details.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 8:58 AM5/28/2020 8:58 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 9: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

UNDISTURBED

NATURAL GRADE

CEMENT STABILIZED

SAND TRENCH DAM

PIPE EMBEDMENT

SEE SPECS

2'

2' TYP.

WATER LINE PIPE

TRENCH DAM DETAIL

1

SCALE: NTS.

SEE PAVEMENT

REPAIR NOTES, D-04

TOP OF TRENCH DAM

UNDISTURBED

NATURAL GROUND

FILTER FABRIC OR

POLYETHYLENE

WRAP PER SPECS

2' M

IN

℄HALF - SECTION

UNDER PAVEMENTS

HALF - SECTION

UNDER OPEN AREAS

6" TOP SOIL

(OPEN AREAS)

1' M

IN

6' M

IN

NORMAL

TRENCH EXCAVATION

LIMITS

CEMENT STABILIZED

SAND TRENCH DAM

BOTTOM OF

TRENCH DAM

SECTION A-A

2

SCALE: NTS.

W

A

T

E

R

L

I

N

E

O

.

D

.

AA

NO.

TRENCH DAM LOCATION

BASE LINE NO.

GENERAL NOTES:

1. REFER TO SPEC 02317 FOR INSTALLATION REQUIREMENTS.

2. KEY CONCRETE TRENCH DAM MINIMUM OF 2-FT INTO TRENCH BOTTOM AND WALLS.

3. TRENCH DAM MAY BE FORMED OR UNFORMED. ACTUAL SHAPE OF CONCRETE

TRENCH DAM CROSS SECTION MAY BE DETERMINED BY CONTRACTOR IN FIELD,

MEETING 2-FT MINIMUM THICKNESS AND 2-FT KEY DEPTH REQUIREMENTS.

4. TRENCH DAM SHALL BE PLACED AT LEAST 5-FT AWAY FROM ANY PIPELINE

STRUCTURE (EACH SIDE). SEE SECTION 02317 FOR OTHER REQUIREMENTS.

5. USE FILTER FABRIC OR POLYETHYLENE WRAP AS A BOND BREAKER BETWEEN

CEMENT STABILIZED SAND AND PIPE.

6. EXTEND TRENCH DAM 6-FT MIN. ABOVE TOP OF SURROUNDING GRANULAR SOIL

LAYERS OR TOP OF GRANULAR EMBEDMENT MATERIAL, WHICHEVER IS HIGHEST.

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

BACKFILL SEE SPEC 02317

1' MIN.

D-05

TRENCH DAM

DETAILS

XX

HORIZ

VERT

2' MIN2' MIN

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-05 Trench Dam Details.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-05 Trench Dam Details.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 9:01 AM5/28/2020 9:01 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
AutoCAD SHX Text
NORMAL TRENCH WIDTH
AutoCAD SHX Text
NORMAL TRENCH WIDTH
AutoCAD SHX Text
NORMAL TRENCH WIDTH
AutoCAD SHX Text
NORMAL TRENCH WIDTH
AutoCAD SHX Text
NORMAL TRENCH WIDTH
AutoCAD SHX Text
NORMAL TRENCH WIDTH
Page 10: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

INSECT SCREEN #16 MESH,

#316 S.S. w/INSULATING

GASKET BETWEEN FLANGES.

1'-6" DIAMETER CONCRETE

(NON-REINF)

PVC VENT

(UV PROTECTED)

(4"Ø)

C

C

P R

OW

15-GAL. CREPE MYRTLE (TYP)

2

---

BREAKWAY VENT PIPE DETAIL

(VENT PIPES WITHIN HARRIS COUNTY ROW)

SCH 80 GALV STEEL SCREWED

COUPLING (4" Ø)

TOP OF CONCRETE

NAT. GROUND

4" SCH 80 GALV

STEEL PIPE

4" - 90° BEND GALV.

STEEL, N.P.T.

FOR SIZE REQUIREMENTS,

STATION AND OFFSET SEE

PLAN & PROFILE

L VENT

PIPE

L VENT

PIPE

4" VENT PIPE

4'-0" MIN.

4" MAX.

3'-0"

1'-0"

MIN.

3'-0"

(S

EE

G

EN

ER

AL

N

OT

E 3

)

L

SEE GENERAL NOTE 4

3'-0" MIN.

4" - 90° BEND, GALV STEEL, N.P.T.

BOLLARD

4" -180° RETURN, GALV

STEEL FLANGES

INSECT SCREEN #16

MESH, #316 S.S. w/

INSULATING GASKET

BETWEEN FLANGES

CROWN

CONCRETE

2-1 1/2" WIDE x 3/16" THICK GALVANIZED STEEL

STRAPS SECURED w/5/8" DIA S.S. BOLTS.

4'-0" MIN.

4" VENT

PIPE

SEE PLAN & PROFILE FOR

SIZE REQUIREMENTS,

STATION AND OFFSET

C VENT

PIPE

L

C VENT PIPE

L

3

---

VENT PIPE W/

BOLLARD DETAIL

(S

EE

G

EN

ER

AL N

OT

E 3)

3'-0"

1'-0"

P R

OW

L

MIN.

ED

GE

O

F P

VM

T.

OR

B

AC

K O

F C

UR

B

SEE GENERAL

NOTE 4

4" CONCRETE PAD

SEE GENERAL NOTE 2

SEE NOTE 2

4" SCH 80 GALV STEEL

VENT PIPE

SEE DETAIL 2, DWG D-10

118.5376

VA

RIE

S

GENERAL NOTE:

1. DETAILS 2 & 3 SHOULD ONLY BE USED WITH ALTERNATE

VENT PIPE CONFIGUARTION WHEN VENT PIPE MUST BE

BROUGHT OUTSIDE MANHOLE FOOTPRINT AS INDICATED

ON PLAN AND PROFILE DRAWINGS. FOR ALL OTHER

CASES, REFER TO DWG D-07 AS NORMAL.

2. PROVIDE 3'x3'x4" WWM CONCRETE PAD CENTERED ON

VENT PIPE FOR ALTERNATE VENT PIPE LOCATIONS

OUTSIDE MANHOLE FOOTPRINT.

3. VERIFY THAT LOCATION OF VENT PIPE SCREEN IS 1

FOOT ABOVE 100-YEAR FLOOD PLAIN ELEVATION OR 4

FEET ABOVE NATURAL GROUND, WHICHEVER IS

HIGHER.

4. FOR VENT PIPE IN HCFCD ROW, INSTALL VENT PIPE NO

MORE THAN 1 FOOT FROM ROW LINE.

5. FOR VENT PIPE IN HCFCD ROW, DO NOT USE DETAIL 2

ON THIS SHEET. TREES NOT TO BE PLANTED IN HCFCD

ROW.

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

2' MIN

1

---

COMBINATION AIR VALVE ASSEMBLY IN ACCESS MANHOLE & PIPING PLAN

SCALE: NTS.

CEMENT STABILIZED SAND

(C.S.S.) FROM BOTTOM OF

TRENCH TO ROADWAY BASE OR

WITHIN 12" OF NATURAL

GROUND, AS APPLICABLE. LIMITS

OF CEMENT STABILIZED SAND TO

EXTEND 2' BEYOND OUTSIDE

WALL OF MANHOLE. USE

POLYETHYLENE WRAP AS A

BOND BREAKER BETWEEN PIPE

AND CEMENT STABILIZED SAND.

ENSURE PROPER COMPACTION

AND FILLING OF C.S.S. IN PIPE

HAUNCHES.

96" PRECAST MANHOLE SECTIONS

SEE SPECIFICATION SECTION 02082

"PRECAST CONCRETE MANHOLES"

STEEL PIPELINE

DIA. VARIES

1

2

48" HEAVY DUTY

ECCENTRIC MANHOLE

RING & COVER, SEE

DETAIL 1, DWG D-10

PRECAST MANHOLE BASE

SECTION SEE SPECIFICATION

SECTION 02082 "PRECAST

CONCRETE MANHOLES"

D-07

D-07

D-06

AIR VALVE DETAILS

(SHEET 1 OF 2)

XX

HORIZ

VERT

ALTERNATE

VENT PIPE LOCATION

SEE NOTE 6, DWG D-07

(FOR WATER LINES 42" & LARGER IN DIAMETER)

1'-0"

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-06 Air Valve Details Sheet 1 Of 2.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-06 Air Valve Details Sheet 1 Of 2.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 8:53 AM5/28/2020 8:53 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 11: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

0'-9" MIN.

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

AIR VALVE DETAILS

(SHEET 2 OF 2)

XX

NTS.

NTS.

D-07

2' MIN

VA

RIE

S

8"

30" ACCESS MANWAY

WITH 30" OUTLET

BLIND FLANGE W/

HOLE FOR 4" PIPE

SEE DETAIL 4, D-08

COMBINATION AIR VALVE ASSEMBLY IN ACCESS MANHOLE

1

SCALE: NTS.

2' MIN

6"

12"

2' MIN

6" M

IN

.

12" MIN.

(TYP)

3" C

LR

.

TY

P.

12" MIN.

(TYP)

12"

96" PRECAST MANHOLE

SECTIONS SEE

SPECIFICATION

SECTION 02082

"PRECAST CONCRETE

MANHOLES"

SEAL w/ MANHOLE

SEALANT (TYP)

SEE NOTE 2

6"

6"

(FOR WATER LINES 42" & LARGER IN DIAMETER)

COMBINATION AIR VALVE ASSEMBLY IN ACCESS MANHOLE

2

SCALE: NTS.

(FOR WATER LINES 42" & LARGER IN DIAMETER)

10"

VAULT PENETRATION

SEE DETAIL 2, D-11

GENERAL NOTES:

1. SEE AWWA C207 FOR METHOD OF ATTACHMENT FOR RING TO OUTLET PIPE.

2. PROVIDE RAM-NEK OR APPROVED EQUAL BETWEEN PRECAST SEGMENTS OF

THE MANHOLE.

3. PROVIDE AN APPROVED PETROLATUM BASED TAPE ENCAPSULATING ALL BOLTS

IN ACCESS MANHOLE.

4. COATING FOR EXPOSED DUCTILE IRON AND STEEL PIPE AND FITTING IN VAULT

SHALL CONFORM TO SPECIFICATION 02518.

5. VERIFY THAT LOCATION OF VENT PIPE SCREEN IS 1 FOOT ABOVE 100-YEAR

FLOOD PLAIN ELEVATION OR 4 FEET ABOVE NATURAL GROUND ELEVATION,

WHICHEVER IS HIGHER.

6. ALTERNATE VENT PIPE CONFIGURATION SHOULD ONLY BE USED AS INDICATED

ON PLANS. INSTALL ALTERNATE VENT PIPE ALONG CENTERLINE OF WATER LINE,

UNLESS OTHERWISE DETERMINED BY R.O.W. NEGOTIATIONS.

10

1

NATURAL GROUND

4" FLANGED NRS GATE VALVE

WITH BEVEL/ MITER GEAR AND

2" OPERATION NUT AS PER

AWWA (C515, 250PSI.)

CEMENT STABILIZED SAND (C.S.S.)

FROM BOTTOM OF TRENCH TO

ROADWAY BASE OR WITHIN 12" OF

NATURAL GROUND, AS APPLICABLE.

LIMITS OF CEMENT STABILIZED

SAND TO EXTEND 2' BEYOND

OUTSIDE WALL OF MANHOLE. USE

FILTER FABRIC OR POLYETHYLENE

WRAP AS A BOND BREAKER

BETWEEN PIPE AND CEMENT

STABILIZED SAND. ENSURE PROPER

COMPACTION AND FILLING OF C.S.S.

IN PIPE HAUNCHES.

HYDROPHILIC WATERSTOPS,

SIKA HYDROTITE CJ, OR

APPROVED EQUAL

4" VENT-O-MAT RBXb OR

APPROVED EQUAL

PRECAST MANHOLE BASE

SECTION SEE SPECIFICATION

SECTION 02082 "PRECAST

CONCRETE MANHOLES"

SEAL WATERTIGHT WITH

NON-SHRINK GROUT (TYP.)

48" HEAVY DUTY ECCENTRIC MANHOLE

RING AND COVER. SEE DETAIL 1, D-10

48" HEAVY DUTY ECCENTRIC MANHOLE

RING AND COVER. SEE DETAIL 1, D-10

4' M

IN

.

4" GROOVED

COUPLING

4" GROOVED

COUPLING

SE

E N

OT

E 5

INSECT SCREEN #16 MESH,

TYPE 316 S.S. WITH INSULATING

GASKET BETWEEN FLANGES.

4'-0" 4'-0"

3'-0" 5'-0"

7'-6"

MIN

.

3"

6"

2'-6"

10

1

6" M

IN

.

EXTEND CONC.

COLLAR AS REQ'D.

ALTERNATE VENT

PIPE LOCATION.

SEE NOTE 6

4" FLG X PE SPOOL

CONC. COLLAR

SEE DETAIL 3, D-10

INSULATING FLANGE KIT, SEE

CATHODIC PROTECTION

DETAILS

4" -180° RETURN,

GALV STEEL FLANGES

4" -180° RETURN,

GALV STEEL FLANGES

4" SCH 80 GALV

STEEL VENT PIPE

4" SCH 80 GALV

STEEL VENT PIPE

3"

12"

12"

12" MIN

2'-6"

12" MIN

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-07 Air Valve Details Sheet 2 Of 2.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-07 Air Valve Details Sheet 2 Of 2.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 9:32 AM5/28/2020 9:32 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 12: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

ACCESS MANHOLE AND MANWAY SECTION

3

SCALE: NTS.

ST

EE

L P

IP

ELIN

E

2' MIN

S

T

E

E

L

P

I

P

E

L

I

N

E

8"

30" ACCESS MANWAY AS

PER AWWA M11, 150 P.S.I.

PROVIDE 30" BLIND FLANGE

W/ HOLE FOR 6" PIPE

SEE DETAIL 4

6" FLANGED NRS GATE VALVE

WITH BEVEL/ MITER GEAR AND

2" OPERATION NUT AS PER

AWWA (C515, 250PSI.)

6"

ACCESS MANHOLE AND MANWAY SECTION

2

SCALE: NTS.

VIEW 1

VIEW 2

2' MIN

6" M

IN

.

2' MIN

O.D. PLUS 4'-0" MIN.

CEMENT STABILIZED SAND (C.S.S.)

FROM BOTTOM OF TRENCH TO

ROADWAY BASE OR WITHIN 12" OF

NATURAL GROUND, AS APPLICABLE.

LIMITS OF CEMENT STABILIZED

SAND TO EXTEND 2' BEYOND

OUTSIDE WALL OF MANHOLE. USE

FILTER FABRIC OR POLYETHYLENE

WRAP AS A BOND BREAKER

BETWEEN PIPE AND CEMENT

STABILIZED SAND. ENSURE PROPER

COMPACTION AND FILLING OF C.S.S.

IN PIPE HAUNCHES.

2' MIN

8"

6"

NATURAL GROUND

12"

2' MIN

6" M

IN

.

12" MIN.

(TYP)

3" C

LR

.

TY

P.

3"

CLR

.

TY

P.

12" MIN.

(TYP)

12"

96" PRECAST

MANHOLE SECTIONS SEE

SPECIFICATION

SECTION 02082

"PRECAST CONCRETE

MANHOLES"

96" I.D.

SEAL W/ MANHOLE

SEALANT (TYP)

SEE NOTE 2

6"

6"

ACCESS MANHOLE AND MANWAY DETAIL

1

SCALE: NTS.

96" PRECAST

MANHOLE SECTIONS SEE

SPECIFICATION

SECTION 02082

"PRECAST CONCRETE

MANHOLES"

15'

48" HEAVY DUTY

ECCENTRIC MANHOLE

RING & COVER, SEE

DETAIL 1, D-10

6" FLANGED NRS GATE VALVE

WITH BEVEL/ MITER GEAR AND

2" OPERATION NUT AS PER

AWWA C515, 250PSI.

30" ACCESS MANWAY AS

PER AWWA M11, 150 P.S.I.

2' MIN.

12" MIN.

TYP.

CEMENT STABILIZED SAND

2

3

O.D. PLUS 4' MIN.

GENERAL NOTES:

1. SEE AWWA C207 FOR METHOD OF ATTACHMENT FOR RING

TO OUTLET PIPE.

2. PROVIDE RAM-NEK OR APPROVED EQUAL BETWEEN

PRECAST SEGMENTS OF THE MANHOLE.

3. PROVIDE AN APPROVED PETROLATUM BASED TAPE

ENCAPSULATING ALL BOLTS IN ACCESS MANHOLE.

4. FOR MANHOLE GREATER THAN OR EQUAL TO 8 FEET DEEP,

PROVIDE FIXED LADDER WITH FALL PROTECTION SYSTEM:

MILLER SAFE-T CLIMB OR APPROVED EQUAL SEE DETAIL 4,

DWG D-10.

5. COATING FOR EXPOSED DUCTILE IRON AND STEEL PIPE

AND FITTING IN MANHOLE SHALL CONFORM TO

SPECIFICATION 02518.

6. FOR PAVEMENT REPAIR, SEE "PAVEMENT REPAIR NOTES

ON SHEET D-04.

7. ALL STRUCTURAL CONCRETE TO HAVE MIN. COMPRESSIVE

STRENGTH OF 4,500 P.S.I. AS SPECIFIED IN SECTION

03315-CONCRETE FOR UTILITY CONSTRUCTION.

8. FOR CAV USE, MATCH OUTLET SIZE TO CAV REFERENCED

IN D-07.

VA

RIE

S

VA

RIE

S

2'-6"

3"

CONCRETE COLLAR

SEE DETAIL 3, D-10

SEE DETAIL "A"

t

t

t

1/2"

30" DIA. STEEL BLIND FLANGE

AWWA C207, CLASS D

3/4" DIA. STEEL BAR

9"

3"

TYPICAL

BOTH SIDES

30" DIA. STEEL BLIND FLANGE

AWWA C207, CLASS D

BLIND FLANGE DETAILS FOR ACCESS MANHOLE MANWAY

4

6" DIA. STEEL

OUTLET PIPE

SCHEDULE 40

SEE NOTE 8

LIFTING HOOK DETAIL

13"

LIFTING HOOKS,

TYPICAL OF 2

6" DIA. STEEL OUTLET

PIPE SCHEDULE 40

SEE NOTE 8

LIFTING HOOK LOCATION DETAIL

30" DIA. STEEL BLIND

FLANGE AWWA C207,

CLASS D

RING FLANGE, AWWA C207, CLASS D

FOR OUTLET PIPE.

SEE NOTE 1

6" DIA STEEL

OUTLET PIPE

SCHEDULE 40

SEE NOTE 8

DETAIL "A"

DETAIL OF ENTRY PORT BLIND FLANGE

WITH OUTLET

3/8"

SCALE: NTS.

10

2'-0"

2'-0"

SEAL WATERTIGHT WITH

NON-SHRINK GROUT (TYP.)

1

HYDROPHILIC WATERSTOPS,

SIKA HYDROTITE CJ, OR

APPROVED EQUAL

SEE NOTE 6

CONCRETE COLLAR

SEE DETAIL 3, D-10

SEE NOTE 6

6" D.I. BLIND FLANGE

w/3/4" CORPORATION STOP

48" HEAVY DUTY ECCENTRIC MANHOLE RING

AND COVER. SEE DETAIL 1, D-10

PRECAST MANHOLE BASE

SECTION SEE SPECIFICATION

SECTION 02082 "PRECAST

CONCRETE MANHOLES"

10

1

SEAL

WATERTIGHT

WITH

NON-SHRINK

GROUT (TYP.)

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

12"

11"

3'-2-3/4"

TYP.

8" M

IN

.

3'-0" 5'-0"

D-08

LARGE DIAMETER

ACCESS MANHOLE

AND MANWAY

XX

HORIZ

VERT

INSULATING FLANGE

KIT, SEE CATHODIC

PROTECTION DETAILS

2'-6"

3"

12"

48" HEAVY DUTY ECCENTRIC MANHOLE RING

AND COVER. SEE DETAIL 1, D-10

12" 12"

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-08 Large Diameter Access Manhole And Manway.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-08 Large Diameter Access Manhole And Manway.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 9:29 AM5/28/2020 9:29 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 13: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

NAT. GND.

(TYP)

W

A

T

E

R

M

A

I

N

MIN

PLAN

MA

X

C VALVE

4'-0

" O

.C

.

MA

X

SEE NOTE 7

MIN

L MANHOLE RISER

MIN

PROVIDE ISOLATION FLANGES AND

ELECTRICAL BONDING ACROSS

VALVE FROM PIPE TO PIPE, SEE

CATHODIC PROTECTION DETAILS

NOTE:

SHOULD CONTRACTOR DESIRE TO USE

VALVES IN A THROTTLED POSITION FOR

FILLING OF LINE SEGMENTS, OBSERVE

RECOMMENDATIONS OF VALVE

MANUFACTURER TO PRECLUDE DAMAGE

ASSOCIATED WITH THROTTLING MODE OF

OPERATION.

C

L

C

HEAVY DUTY ECCENTRIC MANHOLE RING

& COVER (SEE DETAIL 1, DWG D10)

48" PRECAST MANHOLE SECTION SEE

SPECIFICATION SECTION 02082 "MANHOLES"

PROVIDE CONC. COLLAR (6' DIA. OR SQ. x 12" THICK)

WITH 1- #3 BAR CONTINUOUS FOR OPEN AREAS

MAXIMUM TWO 12" STD PRECAST CONC

SECTIONS (SEE NOTE 1)

CONCRETE COLLAR

(SEE DETAIL 3, DWG. D10)

L VALVE OPERATOR

SEE NOTE 5

USE TRUMBALL MFG OR

APPROVED EQUAL WITH A

BEARING FOR HIGH SPEED

POWER STEM OPERATOR

SEE DETAIL 3, THIS SHEET

WALL PENETRATION

(SEE DETAIL 2, DWG. D11)

(SEE NOTES 8, 9, & 10)

PROVIDE OPENING IN

PRECAST MANHOLE =

OUTSIDE DIAMETER OF

PACKING GLAND PLUS 4"

C

L

HALF SECTION FOR

MANHOLE IN OPEN AREA

HALF SECTION FOR

MANHOLE IN PAVEMENT

12" MIN

2'-7"

3'-0

"

24"

48"

51"

4'-0

"

VA

RIE

S (S

EE

N

OT

E 1

1)

7'-6

"1

2"

3

---

VALVE OPERATOR SUPPORT

#6 @ 12" O.C.E.W.

CONCRETE ACTUATOR SUPPORT,

PROVIDE A MINIMUM CLEARANCE OF

6" BETWEEN THE FOUNDATION OF

ACTUATOR AND THE FLANGE OF

THE WATER MAIN

60" DIA

30

"

GENERAL NOTES:

1. PROVIDE RAMNEK OR APPROVED EQUAL BETWEEN

PRECAST SEGMENTS OF THE MANHOLE.

2. PROVIDE AN APPROVED PETROLEUM BASED TAPE

ENCAPSULATING ALL BOLTS IN MANHOLES & VAULTS.

3. ALL JOINTS SHALL BE BONDED, BONDING DETAILS AT

ISOLATION/ BUTTERFLY VALVES. SEE THE CATHODIC

PROTECTION DETAILS.

4. FIELD COAT ALL FLANGE BOLTS, FLANGE COUPLING,

FLANGE COUPLING ADAPTER AND THRUST TIE

ASSEMBLIES AFTER ASSEMBLY TO 35 MDFT W/2

COATS OF COAL TAR EXPOXY.

5. 2" OPERATING NUT ON LARGE DIAMETER BUTTERFLY

VALVES SHALL TURN CLOCKWISE TO OPEN VALVE

ABOVE - GROUND & PLANT VALVES SHALL OPEN

COUNTER CLOCKWISE.

6. PLACE MANHOLE ON COMPACTED (95% SPD) BOTTOM.

7. FOR PAVEMENT REPAIR, SEE PAVEMENT REPAIR

NOTES ON DWG D-04.

8. POLYSULFIDE SEALANT EXTERIOR SIDE OF WALL

PENETRATION ONLY.

9" MIN.

FLOWABLE FILL

BEDDING LAYER (GRANULAR

EMBEDMENT NOT COMPACTED)

FILTER FABRICGRAVEL EMBED

BUTTERFLY

VALVE

BUTTERFLY VALVE

PLAN

C VALVE

C MANHOLE RISER

PROVIDE ISOLATION FLANGES AND

ELECTRICAL BONDING ACROSS

VALVE FROM PIPE TO PIPE, SEE

CATHODIC PROTECTION DETAILS

L

BUTTERFLY

VALVE

NAT. GND.

(TYP)

W

A

T

E

R

M

A

I

N

MIN

MIN

ELEVATION

MA

X

4'-0

" O

.C

.

MA

X

#6 @ 12" O.C.E.W.

SEE NOTE 7

MIN

MIN

60" DIA

C

HEAVY DUTY ECCENTRIC MANHOLE RING

& COVER (SEE DETAIL 1, DWG D10)

PROVIDE CONC. COLLAR (6' DIA. OR SQ. x 12" THICK)

WITH 1- #3 BAR CONTINUOUS FOR OPEN AREAS

BUTTERFLY VALVE

MAXIMUM TWO 12" STD PRECAST CONC

SECTIONS (SEE NOTE 1)

CONCRETE COLLAR

(SEE DETAIL 3, DWG. D10)

2

---

BUTTERFLY VALVE w/ OPERATOR MANHOLE

(FOR WATER LINES 30-INCHES TO 54-INCHES )

L VALVE OPERATOR

SEE NOTE 5

CONCRETE ACTUATOR SUPPORT, PROVIDE A

MINIMUM CLEARANCE OF 6" BETWEEN THE

FOUNDATION OF ACTUATOR AND THE

FLANGE OF THE WATER MAIN

WALL PENETRATION

(SEE DETAIL 2, DWG. D11)

(SEE NOTES 8, 9, & 10)

PROVIDE OPENING IN

PRECAST MANHOLE =

OUTSIDE DIAMETER OF

PACKING GLAND PLUS 4"

C

L

HALF SECTION FOR

MANHOLE IN OPEN AREA

HALF SECTION FOR

MANHOLE IN PAVEMENT

12

"

12" MIN

2'-7"

3'-0

"

24"

48"

51"

4'-0

"

VA

RIE

S (S

EE

N

OT

E 1

1)

7'-6

"1

2"

L

STIFFENING RING (TYP)

SEE NOTE 13

(2) #2 AWG

HMWPE

1

---

BUTTERFLY VALVE w/ OPERATOR MANHOLE

(FOR WATER LINES 54-INCHES AND LARGER )

USE TRUMBALL MFG OR

APPROVED EQUAL WITH A

BEARING FOR HIGH SPEED

POWER STEM OPERATOR

SEE DETAIL 3, THIS SHEET

NOTES:

1. MATCH ANCHOR BOLT

MATERIAL TO TRUMBULL

STEM GUIDE.

MANHOLE WALL

VALVE OPERATOR

USE TRUMBULL STEM GUIDE

OR APPROVED EQUAL. SEE

SPEC 15180.

BRONZE BUSHING

3/4" x 2" ANCHOR

BOLTS (TYP FOR 2)

SEE NOTE 16

9. SOLID SYNTHETIC RUBBER INTERLOCKING

MODULAR LINKS W/STAINLESS STEEL BOLTS AND

NUTS, THUNDERLINE LINK SEAL, OR APPROVED

EQUAL.

10. IF MANHOLE IS CAST IN PLACE CONSTRUCTION,

PROVIDE DETAIL(S) FOR WALL PENETRATION

INCLUDING EXTRA REINFORCING. DETAILS TO BE

SEALED BY PROFESSIONAL ENGINEER LICENSED IN

TEXAS.

11. FOR MANHOLES DEEPER THAN 8 FEET, INCREASE

SIZE OF ACCESS MANHOLES TO 72-INCH OR 84-INCH

DIAMETER & PROVIDE FIXED LADDER WITH

SAF-T-CLIMB OR APPROVED EQUAL. SEE DETAIL 4,

DWG D-10

12. FOR CONCRETE COLLAR SEE DETAIL 3, DWG D-10.

13. ON STEEL PIPE, MANUFACTURERS SHALL SUPPLY

PIPE OR FITTING/ADAPTORS CONNECTED TO THE

BUTTERFLY VALVE WITH MINIMUM

5

8

" THICK X 6"

TALL STIFFENING RINGS UPSTREAM AND

DOWNSTREAM OF BUTTERFLY VALVE. THESE RINGS

SHALL BE PLACED 4' FROM THE CENTERLINE OF THE

BUTTERFLY VALVE AND SHALL BE DESIGNED SUCH

THAT THE PIPE ADJACENT TO VALVE IS LIMITED TO

NO MORE THAN 0.25% DEFLECTION AT THE DEPTH

OF COVER SHOWN ON THE PLANS.

14. THE CONTRACTOR SHALL ENSURE ALL STULLING IN

PIPE ADJACENT TO VALVES REMAINS IN PLACE

UNTIL FLOWABLE FILL HAS BEEN PLACED AND

CURED.

15. CONTRACTOR SHALL PLACE FLOWABLE FILL IN

EQUAL LIFTS ON EITHER SIDE OF PIPE AND VALVE

AND ENSURE THE PIPE AND VALVE REMAIN ROUND

WITHOUT DEFLECTION UNTIL FLOWABLE FILL

CURES.

16. MATCH ANCHOR BOLT MATERIAL TO TRUMBULL

STEM GUIDE.

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

D-09

VALVE AND

SERVICE MANHOLE

XX

HORIZ

VERT

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-09 Valve And Service Manhole.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-09 Valve And Service Manhole.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 9:27 AM5/28/2020 9:27 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 14: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

PICKHOLE & GASKET

GROOVE DETAIL

CONCRETE

PROVIDE EXPANSION

JOINT (TYPICAL)

2-#5 BARS @ 12" O.C.E.W.

ASPHALT

SURFACE

SECTION

1" (25 MM) LETTERING

(RECESSED FLUSH)

(RECESSED FLUSH)

NEOPRENE GASKET

RING SECTION

LIFT HOLE DETAIL

COVER SECTION

INNER

COVER SECTION

OUTER

1 1/4" (32 MM) LETTERING

BOTTOM VIEW

OF COVERS

1/4" DIA (6 MM)

TOP OF MANHOLE & SURFACE OF

CONCRETE TO MATCH FINISHED STREET

GRADE OR NATURAL GROUND ELEVATION

WITHIN HCFCD

59

3

8

"

[1

50

8 M

M] S

Q.

1

1

2

" [38

MM] TYP

(6) 1/2-13 X 2 1/2" HEX

SS BOLTS W/ 1/2" ZINC

PLTD WASHERS

(4) 1/2-13 X 2 1/2"

HEX SS BOLTS W/

1/2" ZINC PLTD

WASHERS

(4) CLOSED

PICKHOLES

62" DIA

[1575 MM]

SEE NOTE 3 FOR

MAHOLE WITHIN

H.C.F.C.D. ROW

SEE LIFT

HOLE DETAIL

3/4" (19 MM)

LETTERING

(RECESSED FLUSH)

23

1

2

" DIA [597 MM]

23" DIA [584 MM]

(TO OUTSIDE

OF GROOVE)

2

1

4

"

[5

7 M

M]

1/4" (6 MM) DIA

NEOPRENE GASKET

1

1

2

"

[3

8 M

M]

TY

P

2

1

4

"

[57 MM]

1

3

8

"

[35 MM]

7

16"

[11 MM]

.180"

[5 MM]

.240"

[6 MM]

1"

[2

5 M

M]

1 1/2" DIA (38 MM)

LIFTING HOLE

TYP (4) PLACES

90° APART

52

1

2

" DIA [1333 MM]

50

3

4

" DIA [1289 MM]

48" DIA [1219 MM]

51" DIA [1295 MM]

1"

[25 MM]

10

"

[2

54

M

M]

2"

[51 MM]

HEAVY DUTY MANHOLE RING AND COVER

EXIST CONCRETE

PAVEMENT

SIDE SLOPE

SURFACE

SIDE SLOPE

SURFACE

Ö

Ö

Ö

Ö

Ö

Ö

Ö

Ö

Ö

Ö

(MANHOLE RING AND COVER TO BE EAST JORDAN IRON WORKS (EJIW) OR EQUAL)

6" STD. STRENGTH GALV. STL.

PIPE FILLED WITH CONC.,

CROWN TOP.

PROVIDE 2-2" WIDE STRIPS OF

REFLECTORIZED TAPE ON BOLLARD (TYP.)

PAINT BOLLARD AND VENT PIPING

FOREST GREEN. COLOR TO BE

SUBMITTED AND APPROVED BY PROGRAM

MANAGER.

CONCRETE TO N.G.

3'-0

"2

'-0

"1

'-0

"

18" DIA.

NOTES - BOLLARDS:

1. CLASS B CONCRETE WILL BE USED IN

AND AROUND BOLLARDS.

2. SEE DETAIL 3, THIS SHEET AND DETAIL 6,

DWG D-11 FOR BOLLARD USAGE.

10"

TYP.

22

" [5

59

M

M]

23

3

4

" D

IA

[6

03

M

M]

1

1

2

"

[38 MM]

50

1

2

" D

IA

[1

28

3 M

M]

2"

[51 MM]

3

3

4

"

[95 MM]

M

A

D

E

IN

U

S

A

E

A

S

T

J

O

R

D

A

N

IR

O

N

W

O

R

K

S

12

"

(M

IN

)

NOTES:

1. CONSTRUCT THE FINAL 2 FEET OF THE MANHOLE AND PLACE

CONCRETE WITHIN BLOCKOUT AFTER STREET PAVEMENT HAS BEEN

INSTALLED OR NATURAL GROUND HAS BEEN RE-ESTABLISHED.

2. ALL MANHOLE COVERS WITHIN HCFCD ROW SHALL BE FLUSH WITH

NATURAL GROUND, SEALED, AND BOLTED.

3. FOR HEAVY DUTY MANHOLE RING, SEE DETAIL 1, THIS DWG.

4. REINFORCEMENT DEPICTED IN DETAIL IS FOR STANDARD CONCRETE

COLLAR CONFIGURATION. EXTEND REINFORCEMENT PER

SPECIFICATIONS IF ALTERNATE OPTION IS USED.

5. FOR BUTTERFLY VALVE MANHOLES ON WATER MAINS 30-INCHES TO

78-INCHES, CENTER MANHOLE IN CONCRETE COLLAR.

6. INSTALL SQUARE COLLAR w/ BOLLARDS AT CORNERS WITHIN

CENTERPOINT ENERGY CORRIDOR. SEE DETAIL 2, THIS SHEET.

ADD ADDITIONAL

TOP AND BOTTOM

#5 EACH SIDE

OF OPENING

EACH FACE

2-#5 BARS @ 12" O.C.E.W.

CONCRETE COLLAR3

SCALE: NTS

SCALE: NTS

1

BOLLARD DETAIL2

SCALE: NTS

SECTION

TOP OF SLAB

1'-0

"

SU

PP

OR

TS

@

6

'-0

" C

/C

M

AX

.

1-0

"

3

8

"x3" STRINGER

1" Ø LADDER RUNGS

GROOVED FOR

TRACTION. WELD IN

STRINGERS

AND GRIND FLUSH

3/16"

TYP

3

8

"x 2

1

4

" SUPPORT

BRACKETS WELDED

TO STRINGER

SAFE-T-CLIMB DEVICE

5

8

" Ø SS HILTI KWIK

BOLTS W/ 4" MIN.

EMBED TYP.

SECTION

3"

1

1

2

"

6"

MA

X

1-0

"

TY

P

SCALE: NTS.

LADDER DETAIL

NOTES:

1. ALL LADDER MENBERS

SHALL BE GALVANIZED

STEEL UNLESS

OTHERWISE NOTED.

MH CHAMBER

STR WALL

3

4

" Ø DROP IN ANCHOR

W/ 4" MAX EMBEDMENT

R AS SPECIFIED ON

DESIGN DRAWINGS

4

CAV MANHOLE COLLAR

(AND ALTERNATE)

SCALE: NTS

SCALE: NTS

12"

10" CONCRETE

COLLAR FOR

STANDARD MANHOLE

TO BE TRUE

7' SQUARE

M

A

D

E

IN

U

S

A

E

A

S

T

J

O

R

D

A

N

IR

O

N

W

O

R

K

S

12

"

(M

IN

)

ADD ADDITIONAL

TOP AND BOTTOM

12"

12

"1

2"

#5 EACH SIDE

OF OPENING

EACH FACE

ALTERNATE CAV

CONFIG. EXTEND

COLLAR AS REQ'D

VA

RIE

S

STANDARD MANHOLE COLLAR

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

D-10

MANHOLE COVER

DETAILS

XX

HORIZ

VERT

AutoCAD SHX Text
IRON WORKS
AutoCAD SHX Text
EAST JORDAN
AutoCAD SHX Text
ASTM A48 CL35B
AutoCAD SHX Text
V-1418
AutoCAD SHX Text
MO/DAY/YR X
AutoCAD SHX Text
41418168
AutoCAD SHX Text
47048233
AutoCAD SHX Text
MO/DA/YR J
AutoCAD SHX Text
V-7048-2
AutoCAD SHX Text
GS
AutoCAD SHX Text
IRON WORKS
AutoCAD SHX Text
EAST JORDAN
AutoCAD SHX Text
GS
AutoCAD SHX Text
MADE IN USA
AutoCAD SHX Text
Y
AutoCAD SHX Text
T
AutoCAD SHX Text
N
AutoCAD SHX Text
U
AutoCAD SHX Text
O
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
A
AutoCAD SHX Text
H
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
W
AutoCAD SHX Text
V-7048
AutoCAD SHX Text
MO/DA/YR
AutoCAD SHX Text
V-7048-2
AutoCAD SHX Text
WATER
AutoCAD SHX Text
47048010
AutoCAD SHX Text
EAST JORDAN
AutoCAD SHX Text
IRON WORKS
AutoCAD SHX Text
MADE IN USA
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
O
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
L
AutoCAD SHX Text
W
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
A
AutoCAD SHX Text
U
AutoCAD SHX Text
T
AutoCAD SHX Text
H
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
I
AutoCAD SHX Text
T
AutoCAD SHX Text
Y
AutoCAD SHX Text
Y
AutoCAD SHX Text
T
AutoCAD SHX Text
N
AutoCAD SHX Text
U
AutoCAD SHX Text
O
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
A
AutoCAD SHX Text
H
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
W
AutoCAD SHX Text
V-7048
AutoCAD SHX Text
MO/DA/YR
AutoCAD SHX Text
V-7048-2
AutoCAD SHX Text
WATER
AutoCAD SHX Text
47048010
AutoCAD SHX Text
MADE IN USA
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
O
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
L
AutoCAD SHX Text
W
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
A
AutoCAD SHX Text
U
AutoCAD SHX Text
T
AutoCAD SHX Text
H
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
I
AutoCAD SHX Text
T
AutoCAD SHX Text
Y
AutoCAD SHX Text
Y
AutoCAD SHX Text
T
AutoCAD SHX Text
N
AutoCAD SHX Text
U
AutoCAD SHX Text
O
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
A
AutoCAD SHX Text
H
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
W
AutoCAD SHX Text
V-7048
AutoCAD SHX Text
MO/DA/YR
AutoCAD SHX Text
V-7048-2
AutoCAD SHX Text
WATER
AutoCAD SHX Text
47048010
AutoCAD SHX Text
MADE IN USA
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
O
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
L
AutoCAD SHX Text
W
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
A
AutoCAD SHX Text
U
AutoCAD SHX Text
T
AutoCAD SHX Text
H
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
I
AutoCAD SHX Text
T
AutoCAD SHX Text
Y
AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-10 Manhole Cover Details.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-10 Manhole Cover Details.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 9:50 AM5/28/2020 9:50 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 15: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

PR

EC

AS

T

CO

NC

RE

TE

ST

RU

CT

UR

E

CA

ST

-IN

-P

LA

CE

CO

NC

RE

TE

ST

RU

CT

UR

E

POLYSULFIDE SEALANT

EXTERIOR SIDE ONLY

FILL VOID BEHIND PIPE

SLEEVE w/NON-SHRINK

GROUT

SOLID SYNTHETIC RUBBER

INTERLOCKING MODULAR LINKS

w/STAINLESS STEEL BOLTS AND

NUTS, THUNDERLINE LINK SEAL,

OR APPROVED EQUAL

PVC WATERSTOP

OR APPROVED EQUAL

2 - #5 BARS

L PIPE

C

CONCRETE

GROUND LEVEL

C

L

WATER MAIN

CARSONITE FLATTOP

LINEMARKER ENHANCER

MODEL #CRFE01608

12"

DE

PT

H

18"

48"

2"

3" DIA, WHITE, SCHEDULE

40 PVC (UV PROTECTED)

VA

RIE

S

DIA

NOTES:

VARIES

WHCRWA

BEFORE

DIGGING

CALL

281-398-8211

PIPELINE

WATER

WAR

NING

WATER LINE MARKER1

--

TYPICAL WALL PENETRATION DETAIL2

--

C900 PVC OR C.I. OR D.I. PIPE

2" OPERATING NUT

WATER MAIN

VALVE BOX DETAIL

3

--

VALVE BOX COVER DETAIL

5

--

PREMOLDED JOINT

SEALER ALL AROUND

ADJUST TO

NATURAL GROUND

VALVE BOX RISER

(EJIW OR EQUAL)

UNLESS OTHERWISE

NOTED, INSTALL VALVE

STEM EXTENSION WITH

CENTERING DEVICE TO

WITHIN 4' OF FINISH

GRADE

10"

MIN.

8"

4'-0" M

AX

.

1

1

2

"

5

8

"

7

3

8

" DIA.

3

8

" DIA.

5

8

" DIA.

6

7

8

" DIA.

2

1

2

"

3

4

"

7

16

"

7

8

"

WEST HARRIS

COUNTY

REGIONAL WATER

AUTHORITY

(EAST JORDAN IRON WORKS (EJIW) OR EQUAL)

VALVE BOX COVER (EJIW OR EQUAL)

(DETAIL 5, THIS DWG.)

WHEN VALVES ARE

LOCATED IN ROADS,

DRIVEWAYS, OR SIDEWALKS

CONCRETE PAD AROUND

TOP OF VALVE BOXES TO BE

30 SQUARE INCH, 8-INCH

THICK, REINFORCE W/ #3

REINF., BARS 08" C-C BOTH

WAYS, TWO LAYERS

BELL END OF PIPE

NOTES:

1. ~ WEIGHTS FRAME - 45 LBS, COVER - 10 LBS

2. MATERIAL - GRAY IRON ASTM A48 CL35B

NOTES:

1. WATER LINE MAKER TO BE INSTALLED AT THE FOLLOWING

LOCATIONS. NO SEPARATE PAY

- STREET ROW ON BOTH SIDES 1FT INSIDE ROW.

- HARRIS COUNTY FLOOD CONTROL DRAINAGE EASEMENTS

ON BOTH SIDES 1FT INSIDE ROW.

- CROSSING PIPELINE CORRIDORS ON BOTH SIDES.

- CHANGES IN WATERLINE HORIZONTAL DIRECTION GREATER

THAN 20 DEGREES.

- OTHER LOCATIONS AS INDICATED ON PLANS.

PR

EC

AS

T

CO

NC

RE

TE

ST

RU

CT

UR

E

CA

ST

-IN

-P

LA

CE

CO

NC

RE

TE

ST

RU

CT

UR

E

2 - #5 BARS

L PIPE

C

VARIES

RESILIENT VAULT/MANHOLE CONNECTOR

W/ STAINLESS STEEL HARDWARE, PRESS-SEAL

PSX: DIRECT DRIVE OR APPROVED EQUAL

STAINLESS STEEL PIPE CLAMP

1. POLYSULFIDE SEALANT EXTERIOR SIDE ONLY.

2. SOLID SYNTHETIC RUBBER INTERLOCKING MODULAR LINKS

w/STAINLESS STEEL BOLTS AND NUTS, THUNDERLINE LINK SEAL, OR

APPROVED EQUAL.

3. IF MANHOLE IS CAST IN PLACE CONSTRUCTION, PROVIDE DETAIL(S)

FOR WALL PENETRATION INCLUDING EXTRA REINFORCING. DETAILS

TO BE SEALED BY A PROFESSIONAL ENGINEER LICENSED IN TEXAS.

4. CAST OR CORE PENETRATION W/IN MANUFACTURER'S SPECIFIED

TOLERANCES FOR THE PRODUCT. INSTALL CONNECTOR PER

MANUFACTURER RECOMMENDATIONS.

5. COORDINATE WITH SEAL MANUFACTURER FOR SIZE OF STEEL

SLEEVE.

STEEL SLEEVE w/SEEP RING

TIGHT COLLAR.

SEE DETAIL 4 THIS SHEET

STEEL SLEEVE w/SEEP RING

TIGHT COLLAR.

SEE DETAIL 4 THIS SHEET

STAINLESS STEEL EXPANSION RING

FILL VOID BEHIND PIPE

SLEEVE w/NON-SHRINK

GROUT

PVC WATERSTOP

OR APPROVED EQUAL

SCALE: NTS.

SCALE: NTS.

VARIES

2"

3

8

"

VA

RIE

S

STEEL SLEEVE W/SEEP RING4

--SCALE: NTS.

SCALE: NTS.

SCALE: NTS.

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

D-11

STANDARD

WATER LINE DETAILS

XX

HORIZ

VERT

AutoCAD SHX Text
EJIW
AutoCAD SHX Text
MADE IN USA
AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-11 Standard Water Line Details.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-11 Standard Water Line Details.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 9:22 AM5/28/2020 9:22 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY
Page 16: WEST HARRIS COUNTY REGIONAL WATER AUTHORITY

LOCATION WATER MAIN

DIAMETER (IN)

PIPE

MATERIAL

STA. XX+XX TO STA. XX+XX XX

NOMINAL DIA/WALL THICKNESS (NOTE 1)

(IN) (IN)

2-FLANGE LINER

PLATE (SEE NOTE 2)

4-FLANGE

LINER PLATE

CASING

I.D. / WALL

THICKNESS

STEELXX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

X.XXX

X.XXX

X.XXX

X.XXX

STA. XX+XX TO STA. XX+XX XX STEEL XX/X.XXXX X.XXX

STA. XX+XX TO STA. XX+XX XX

STEEL

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

X.XXX

X.XXX

X.XXX

X.XXX

MINIMUM TUNNEL LINER / CASING SIZES AND THICKNESS

NOTES:

1. DIAMETER OF LINER PLATE IS AT NEUTRAL AXIS.

2. LINER PLATE IS TWO FLANGE AND NOMINALLY 2-INCH CORRUGATION BY 6-INCH PROFILE.

3. ALL JOINTS WITHIN LIMITS OF CASING MUST BE RESTRAINED.

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

X.XXX

X.XXX

X.XXX

X.XXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX STEEL XX/X.XXXX XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX STEEL XX/X.XXXX XX/X.XXXX

STA. XX+XX TO STA. XX+XX XX STEEL XX/X.XXXX XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

XX/X.XXXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

X.XXX

TUNNEL DETAIL EXAMPLE -

TO BE REPLACED

BY CONSULTANT

STEEL

STEEL

STEEL

STEEL

STEEL

STEEL

STEEL

STEEL

STEEL

STEEL

STEEL

STEEL

STEEL

Standard D

etails V

er. M

arch 2020

Program Manager

DANNENBAUM

ENGINEERING CORPORATION

08/31/2019

Date

Registration Number

Engineer

INTERIM REVIEW ONLY

John D. Doe

XXXXX

Not to be used for construction, bidding,

permit or regulatory approval

purposes.This document is released for

the purpose of interim review under the

authority of:

Engineer of Record

Texas Registered Engineering Firm F-#XXX

Company Name

Address

Telephone No.

Texas Firm No.

CONTRACT KM "X"

D-12

TUNNEL AND

CASING DETAILS

XX

HORIZ

VERT

AutoCAD SHX Text
PEN TABLE: SWSP-34x22-PDF.ctbSWSP-34x22-PDF.ctb
AutoCAD SHX Text
FILE PATH: G:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-12 Tunnel & Casing.dwgG:\1110\STANDARDS\SWSP_Kinder Morgan (Standard Details)\Standard Details\01-Details\D-12 Tunnel & Casing.dwg
AutoCAD SHX Text
PLOTTED: 5/28/2020 9:35 AM5/28/2020 9:35 AM
AutoCAD SHX Text
NO. DATE REVISION APP.
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
MM/DD/YY BRIEF DESCRIPTION XXX
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
HOUSTON PUBLIC WORKS
AutoCAD SHX Text
CITY OF HOUSTON
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
OF XXX
AutoCAD SHX Text
DRAWING SCALE
AutoCAD SHX Text
HORIZ: VERT:
AutoCAD SHX Text
NOTE: CITY SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
TRAFFIC & TRANSPORTATION/ STREET & BRIDGE
AutoCAD SHX Text
FOR CITY OF HOUSTON USE ONLY
AutoCAD SHX Text
WATER
AutoCAD SHX Text
STORM WATER QUALITY