16
West Elara West Elara is constructed at Jurong Shipyard in Singapore and was delivered in Q3, 2011. West Elara is designed to operate in harsh environments, in water-depths up to 150 m with drilling depths down to 10,670 m. For further information contact: Marketing - Contract Tel: +4751309000 E-mail: [email protected] Web: www.seadrill.com GENERAL Design Gusto MSC CJ70-X150A Built/year JSPL / 2011 Flag Norway Classification DNV Class notations +1A1 Self Elevating Drilling Unit E0, DRILL(N), CRANE & HELDK MAIN DIMENSIONS/TECHNICAL Length x breadth 88,6m (hull longitude) x 97,2m (hull transversal) Design max WD 150 m* Design min WD 25 m* Drilling depth 10 670 m Variable load 20,676 mT (Operational) Helideck HELDK, S92/ EC225 Accommodation 120 STORAGE CAPACITIES Fuel 2040 m3 Drill water 3557 m3 Potable water 538 m3 Liquid mud WBM 854 m3 OBM 854 m3 Base oil 608 m3 Brine 889 m3 Barite/Bentonite 315 m3 Cement 228 m3 DRILLING EQUIPMENT Derrick 1134 mt Drawworks TTS Sense Ultra Hoist 1250-5600 Racking capacity 8,260 m 6 5/8”, 4,360 m 5 7/8” BHA 744 m DC/BHA Csg storage 13 3/8” or 9 5/8” or 7 Top drive TTS Sense TD 1150 AC- 2M (Dual AC) 2 x 850 kW - continuous torque 122,1 kNm Rotary table 1.54 m VBJ RST (60,5”) Iron roughneck 2 x JIM 20 w/ integrated pipe cleaning, doping and mud bucket * Subject to seabed fixation WELL CONTROL BOP 4 ram BOP - Hydril 0.467 m (18.75”) 2 x double 1034 bar (15ksi) 1 Annular Hydril GX Diverter Vetco KFDS CSO 1,25 m (49½”) Diverter housing C&K manifold Techdrill 1034 bar (15Kpsi) TENSION SYSTEM Conductor tension 400 mt (883 kips) BOP HANDLING BOP crane Sense 2 x 60 mt BOP Skid 120 sh-ton MUD SYSTEM 517 bar Mud pumps 2 x 4 MI Swaco BEM 650 Shakers Pressure rating Wirth TPK 7 ½” x 14” / 2200 3 x 1,620 kW (2,200 hp) Solids control 2 with Mud cleaning device. Segregated for WBM/ OBM handling POWER Main engines 4 x Cat C280-12 Main generators 3 460 bkW Total power 13,84 MW Mooring lines Harbour mooring and rig positioning Mooring winches 4 x 800kN winch/ 2050kN brake LIFTING EQUIPMENT Deck crane NOV - 3 x 85 mt Deck crane rating 85 mt Pipe handling crane Knuckle boom crane OTHER FEATURES Offline stand building of drill pipes and casing Dual mud system for both WBM/OBM, large storage area and long out reach.

West Elara - nadlcorp.com/media/Files/N/NADL/drilling-units/west-elara... · West Elara West Elara is constructed at Jurong Shipyard in Singapore and was delivered in Q3, ... PIPERACK

  • Upload
    hanhu

  • View
    221

  • Download
    2

Embed Size (px)

Citation preview

West Elara West Elara is constructed at Jurong Shipyard in Singapore and was delivered in Q3, 2011. West Elara is designed to operate in harsh environments, in water-depths up to 150 m with drilling depths down to 10,670 m. For further information contact: Marketing - Contract Tel: +4751309000 E-mail: [email protected] Web: www.seadrill.com GENERAL Design Gusto MSC CJ70-X150A Built/year JSPL / 2011 Flag Norway Classification DNV Class notations +1A1 Self Elevating

Drilling Unit E0, DRILL(N), CRANE & HELDK

MAIN DIMENSIONS/TECHNICAL Length x breadth 88,6m (hull longitude) x

97,2m (hull transversal) Design max WD 150 m* Design min WD 25 m* Drilling depth 10 670 m Variable load 20,676 mT (Operational) Helideck HELDK, S92/ EC225 Accommodation 120 STORAGE CAPACITIES Fuel 2040 m3 Drill water 3557 m3 Potable water 538 m3 Liquid mud WBM 854 m3

OBM 854 m3 Base oil 608 m3 Brine 889 m3 Barite/Bentonite 315 m3 Cement 228 m3 DRILLING EQUIPMENT Derrick 1134 mt Drawworks TTS Sense Ultra Hoist

1250-5600 Racking capacity 8,260 m 6 5/8”, 4,360 m

5 7/8” BHA 744 m DC/BHA Csg storage 13 3/8” or 9 5/8” or 7 Top drive TTS Sense TD 1150 AC-

2M (Dual AC) 2 x 850 kW - continuous torque 122,1 kNm Rotary table 1.54 m VBJ RST (60,5”) Iron roughneck 2 x JIM 20 w/ integrated

pipe cleaning, doping and mud bucket

* Subject to seabed fixation

WELL CONTROL BOP 4 ram BOP - Hydril 0.467

m (18.75”) 2 x double 1034 bar (15ksi) 1 Annular Hydril GX

Diverter Vetco KFDS CSO 1,25 m (49½”) Diverter housing

C&K manifold Techdrill 1034 bar (15Kpsi)

TENSION SYSTEM Conductor tension 400 mt (883 kips) BOP HANDLING BOP crane Sense 2 x 60 mt BOP Skid 120 sh-ton MUD SYSTEM 517 bar Mud pumps 2 x 4 MI Swaco BEM 650

Shakers Pressure rating Wirth TPK 7 ½” x 14” /

2200 3 x 1,620 kW (2,200 hp)

Solids control 2 with Mud cleaning device. Segregated for WBM/ OBM handling

POWER Main engines 4 x Cat C280-12 Main generators 3 460 bkW Total power 13,84 MW Mooring lines Harbour mooring and rig

positioning Mooring winches 4 x 800kN winch/ 2050kN

brake LIFTING EQUIPMENT Deck crane NOV - 3 x 85 mt Deck crane rating 85 mt Pipe handling crane Knuckle boom crane OTHER FEATURES Offline stand building of drill pipes and casing Dual mud system for both WBM/OBM, large storage area and long out reach.

TRACK RECORD WEST ELARA

West Elara Page 1 of 1

Country Operator Field / Well name

Water depth (m)

Well depth MD (m)

Well type (appraisal, exploration, development HTHP etc.)

Well start date

Norway Statoil Valemon B-17 133,5 6520 Development HPHT Present Norway Statoil Valemon B-09 133,5 5904 Development HPHT Sep.-2015 Norway Statoil Valemon B-03 133,5 5571 Development HPHT July-2015 Norway Statoil Valemon B-07 133,5 5179 Development HPHT April .2015 Norway Statoil Valemon B-2 133,5 5414 Development HPHT June-2014 Norway Statoil Valemon B-8 133,5 1340 Water injector Febr.-2014 Norway Statoil Valemon B-12 133,5 5406 Development HPHT Jan.-2014 Norway Statoil Valemon B-14 133,5 5297 Development HPHT Jan.-2014 Norway Statoil Valemon B-13 133,5 4810 Development HPHT June-2013 Norway Statoil Valemon B19a 133,5 1350 Cuttings reinjectot Nov.-2012 Norway Statoil Valemon B-18 133,5 345, Only

conductor Development HPHT Oct.-.2012

Norway Statoil GFSAT 34/10-E-2AH

133 3761 Gas injector, recompletion

Mar.2012-Sept.2012

Norway

Statoil GFSAT 34/10-E 1Y3H

133 3767 Gas injector, recompletion

Mar.2012-Sept.2012

Norway Statoil GFSAT 133 3764 Recompletion Mar.2012-Sept.2012

Rev A Date 01.08.2015 Synergi 1140319 side 1 av 12

Unit/Service HP01-M19 Cuttings Handeling (High preformance) remark location loc. Descr. Feed tag connection Drawing

Location Main Deck Stbd LegLxBxH (m) TBA (OFE)Weight (t) TBA (OFE)

Power Supply 690/80 690 VAC 3-phase 60Hz, up to 80A L-LW-03-00 JACKING LEG WELL AFT, STBD 875EN114 HP01-M19-EJ01 Junction Box

Power Supply 690/175 690 VAC 3-phase 60Hz, up to 175A M-MD-09-20MAIN DECK,

PIPERACK DECK STBD

875EN114 HP01-M19-EJ02 Junction Box

Power Supply 690/250 690 VAC 3-phase 60Hz, up to 250A M-MD-09-20MAIN DECK,

PIPERACK DECK STBD

875EN114 HP01-M19-EJ03 Junction Box

Power Supply 690/650 690 VAC 3-phase 60Hz,up to 650A L-LW-03-00 JACKING LEG WELL AFT, STBD 875EN114 HP01-M19-EJ04 Junction Box

Power Supply 230/16 230 VAC 50/60Hz 16A socket L-LW-03-00 JACKING LEG WELL AFT, STBD 875EL112.001-X01 875EL112.001-X01 STAHL 8570/11-301

16A 6h 2P+PE

Power Supply 230/16 230 VAC 50/60Hz 16A socket L-LW-03-00 JACKING LEG WELL AFT, STBD 875EL112.002-X01 875EL112.002-X01 STAHL 8570/11-301

16A 6h 2P+PEPhone TL Telephone 2 lines Analog 425-RP-001 Terminal blocksPA PA-A PA/GA-A and PA/GA-B 100V PA/GA - A Terminal blocksPA PA-B PA/GA-A and PA/GA-B 100V PA/GA - B Terminal blocks

Datacomm Lan Fibre optic connection for data communication Multi mode fibre 423-RQ108 MM / ST

Alarm AL-LEL HC Gas alarm Pot.fre. - NO FS 074 Terminal blocksAlarm AL-H2S H2S Gas alarm Pot.fre. - NO FS 074 Terminal blocksAlarm AL-Fire Fire alarm Pot.fre. - NO FS 074 Terminal blocksAlarm AL-OP Loss of overpressure alarm Pot.fre. - NO FS 074 Terminal blocks

Alarm AL-APS Status signal and shut down signal for UPS’s).

Pot.fre. - NO24V DC - NDE FS 081 Terminal blocks

Diesel FO Diesel-oilPlant Air SA-R Plant air, 40 meter hose on reel.Instrument Air IA Instrument air connection.Fresh water DW-R Fresh water, 40 meter hose on reel.

HP Washdown HPW-R High-pressure water washing system, 40 meter hose on reel.

Hydraulic Outlet HYD Hydraulic oil outlet connected to the

hydraulic oil ringline.

CJ70-CCR036-E-007-02

CJ70-CCR066-E-006-01L-LW-03-00 JACKING LEG WELL AFT, STBD

CJ70-CCR036-E-007-04

HP01-M19-J01

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 2 av 12

Unit/Service HP02-M09 Well testing (High preformance utility station) remark location loc. Descr. Feed tag connection Drawing

Location Pipe Rack main deck port side LxBxH (m) TBA (OFE)Weight (t) TBA (OFE)

Power Supply 690/80 690 VAC 3-phase 60Hz, up to 80A Q-LQ-01-11

MAINDECK, ELECTRICAL EQUIPMENT ROOM STBD

875EN116B Cabinet8 mm bolt

Power Supply 690/175 690 VAC 3-phase 60Hz, up to 175A Q-LQ-01-11

MAINDECK, ELECTRICAL EQUIPMENT ROOM STBD

875EN116B Cabinet10 mm bolt

Power Supply 440/250 440VAC 3-phase 60 Hz 250A Q-LQ-01-11

MAINDECK, ELECTRICAL EQUIPMENT ROOM STBD

875EN116BA Cabinet8 mm bolt

Power Supply 440/30 440VAC 3-phase 60 Hz 30A Q-LQ-01-11

MAINDECK, ELECTRICAL EQUIPMENT ROOM STBD

875EN116BA Cabinet8 mm bolt

Power Supply 230/16 230 VAC 60Hz 16A socket M-MD-09-10

MAIN DECK, PIPERACK DECK

PORT & WELL TEST AREA

875EL113.001-X01 875EL113.001-X01 STAHL 8570/11-30116A 6h 2P+PE

Power Supply 230/16 231 VAC 60Hz 16A socket M-MD-09-10

MAIN DECK, PIPERACK DECK

PORT & WELL TEST AREA

875EL113.002-X01 875EL113.002-X01 STAHL 8570/11-30116A 6h 2P+PE

Power Supply 230/16 232 VAC 60Hz 16A socket M-MD-09-10

MAIN DECK, PIPERACK DECK

PORT & WELL TEST AREA

875EL113.003-X01 875EL113.003-X01 STAHL 8570/11-30116A 6h 2P+PE

Power Supply 230/16 233 VAC 60Hz 16A socket M-MD-09-10

MAIN DECK, PIPERACK DECK

PORT & WELL TEST AREA

875EL113.004-X01 875EL113.004-X01 STAHL 8570/11-30116A 6h 2P+PE

Power Supply 230/16 234 VAC 60Hz 16A socket M-MD-09-10

MAIN DECK, PIPERACK DECK

PORT & WELL TEST AREA

875EL113.005-X01 875EL113.005-X01 STAHL 8570/11-30116A 6h 2P+PE

Power Supply 230/16 234 VAC 60Hz 16A socket M-MD-09-10

MAIN DECK, PIPERACK DECK

PORT & WELL TEST AREA

875EL113.006-X01 875EL113.006-X01 STAHL 8570/11-30116A 6h 2P+PE

Power Supply 230/16 234 VAC 60Hz 16A socket M-MD-09-10

MAIN DECK, PIPERACK DECK

PORT & WELL TEST AREA

875EL113.007-X01 875EL113.007-X01 STAHL 8570/11-30116A 6h 2P+PE

Phone TL Telephone 2 lines Analog 425-RP-001 Terminal blocksPA PA-A PA/GA-A and PA/GA-B 100V PA/GA - A Terminal blocks

875EN116B

CJ70-CCR036-E-007-03

CJ70-CCR036-E-007-04

875EN116A

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 3 av 12

PA PA-B PA/GA-A and PA/GA-B 100V PA/GA - B Terminal blocks

Datacomm Lan Fibre optic connection for data communication Multi mode fibre 423-RQ108 MM / ST

Alarm AL-LEL HC Gas alarm Pot.fre. - NO FA 074 Terminal blocksAlarm AL-H2S H2S Gas alarm Pot.fre. - NO FA 074 Terminal blocksAlarm AL-Fire Fire alarm Pot.fre. - NO FA 074 Terminal blocksAlarm AL-OP Loss of overpressure alarm Pot.fre. - NO FA 074 Terminal blocks

Alarm AL-APS Status signal and shut down signal for UPS’s).

Pot.fre. - NO24V DC - NDE FS 081 Terminal blocks

Sensor fire/gas Sn-LEL LEL Sensor 4-20 mA FS 074 Terminal blocks

Sensor fire/gas Sn-H2S H2S Sensor 4-20 mA FS 074 Terminal blocks

Sensor fire/gas Sn-Fire Smoke Detector Autronica Autrosafe FS 072 Terminal blocks

Instrument cableCC-10p 10 pair instrument cable from well test area to drillers cabin HP02-M09-001 Terminal blocks

Instrument cableCC-2p 2 pair instrument cable from well test area to CCR HP02-M09-002 Terminal blocks

Instrument cableCC-1p 1 pair instrument cable from well test area to each of the lifeboat stations HP02-M09-003/4 Terminal blocks

Instrument cableCC-2p 2 pair instrument cable from well test area to company man office. HP02-M09-005 Terminal blocks

Instrument cableCC-2p 2 pair instrument cable from well test area to area for air compressor unit HP02-M09-006 Terminal blocks

Diesel FO Diesel-oilPlant Air SA-R Plant air, 40 meter hose on reel.Instrument Air IA Instument air connectionFresh water DW-R Fresh water, 40 meter hose on reel.

HP Washdown HPW-R High-pressure water washing system, 40 meter hose on reel.

Hydraulic Outlet HYD Hydraulic oil outlet connected to the

hydraulic oil ringline.

M-MD-09-10

MAIN DECK, PIPERACK DECK

PORT & WELL TEST AREA

HP02-M09-J01 CJ70-CCR066-E-004-01CJ70-CCR066-E-004-02

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 4 av 12

Unit/Service HP03-C08 Wire Line (High preformance utility station) remark location loc. Descr. Feed tag connection Drawing

Location Cantilever pipe deck fwd

Power Supply 690/80 690 VAC 3-phase 60Hz, up to 80A C-PR-05-00PORT,

PLATFORM, PIPERACK DECK

875EN112MCC DRILL. - B -

+N22 NA01HP03-C8-EJ01 Junction box

Power Supply 690/175 690 VAC 3-phase 60Hz, up to 175A C-PR-05-00PORT,

PLATFORM, PIPERACK DECK

875EN112MCC DRILL. - B -

+N22 NA01HP03-C8-EJ02 Junction box

Power Supply 690/80 690 VAC 3-phase 60Hz, up to 80 A C-PR-05-00PORT,

PLATFORM, PIPERACK DECK

MCC DRILL. - B - +N22 MA01 HP03-C8-EJ03 Junction box

Power Supply 690/80 690 VAC 3-phase 60Hz, up to 80 A ESD 2 C-PR-05-00PORT,

PLATFORM, PIPERACK DECK

MCC DRILL. - B - +N24 BA01 874EN001.063 - EJ01 Junction box

Power Supply 230/16 230 VAC 60Hz 16A socket C-PR-05-00PORT,

PLATFORM, PIPERACK DECK

570-FX-200.047 570-FX-200.047 STAHL 8570/11-30116A 6h 2P+PE

Power Supply 230/16 230 VAC 60Hz 16A socket C-PR-05-00PORT,

PLATFORM, PIPERACK DECK

570-FX-200.048 570-FX-200.048 STAHL 8570/11-30116A 6h 2P+PE

Phone TL Telephone 2 lines Analog 425-RP-001 Terminal blocksPA PA-A PA/GA-A and PA/GA-B 100V PA/GA - A Terminal blocksPA PA-B PA/GA-A and PA/GA-B 100V PA/GA - B Terminal blocks

Datacomm Lan Fibre optic connection for data communication Multi mode fibre 423-RQ108 MM / ST

Alarm AL-LEL HC Gas alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-H2S H2S Gas alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-Fire Fire alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-OP Loss of overpressure alarm Pot.fre. - NO FS 073 Terminal blocks

Alarm AL-APS Status signal and shut down signal for UPS’s).

Pot.fre. - NO24V DC - NDE FS 081 Terminal blocks

Sensor fire/gas Sn-Fire Smoke Detector Autronica Autrosafe FS 073 Terminal blocks

CCTV CCTV-M CCTV for 3rd party equipment locations including monitors and control pad Hernis 311-JC-101 Terminal blocks

Diesel FO Diesel-oil

Plant Air SA-R Plant air with at least 40 meter hose on reel.

Instrument Air IA Instument air connection

Fresh water DW-R Fresh water, with at least 40 meter hose on reel.

HP Washdown HPW-R High-pressure water washing system, 40 meter hose on reel.

Hydraulic Outlet HYD Hydraulic oil outlet connected to the

hydraulic oil ringline.

HP03-C08-J01 CJ70-CCR066-E-005-01C-PR-05-00PORT,

PLATFORM, PIPERACK DECK

CJ70-CCR036-E-007-01

CJ70-CCR036-E-007-04 / J001-LOG-570-E-XK-

0002-04

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 5 av 12

Unit/Service ST01-M18 Wellhead Utility Station 1 (Standard utility station) remark location loc. Descr. Feed tag connection Drawing

Location Stbd Side, AftPower Supply 690/40 690 VAC 3-phase 60Hz, up to 40A 875EN115 Junction boxPower Supply 690/80 690 VAC 3-phase 60Hz, up to 80A 875EN115 Junction box

Power Supply 230/16 230 VAC 60Hz 16A socket L-LW-03-00 JACKING LEG WELL AFT, STBD 875EL112.003-X01 875EL112.003-X01 Junction box

Power Supply 230/16 230 VAC 60Hz 16A socket L-LW-03-00 JACKING LEG WELL AFT, STBD 875EL112.004-X01 875EL112.004-X01 Junction box

Phone TL Telephone 2 lines Analog 425-RP-001 Terminal blocksPA PA-A PA/GA-A and PA/GA-B 100V PA/GA - A Terminal blocksPA PA-B PA/GA-A and PA/GA-B 100V PA/GA - B Terminal blocks

Datacomm Lan Fibre optic connection for data communication (LAN connection). Multi mode fibre 423-RQ108 MM / ST

Alarm AL-LEL HC Gas alarm Pot.fre. - NO FS 074 Terminal blocksAlarm AL-H2S H2S Gas alarm Pot.fre. - NO FS 074 Terminal blocksAlarm AL-Fire Fire alarm Pot.fre. - NO FS 074 Terminal blocksAlarm AL-OP Loss of overpressure alarm Pot.fre. - NO FS 074 Terminal blocks

Alarm AL-APS Status signal and shut down signal for UPS’s).

Pot.fre. - NO24V DC - NDE FS 081 Terminal blocks

Plant Air SA-R Plant air with at least 40 meter hose on reel.

Instrument Air IA Instument air connection

Fresh water DW-R Fresh water, with at least 40 meter hose on reel.

HP Washdown HPW-R High-pressure water washing system, 40 meter hose on reel.

Hydraulic Outlet HYD Hydraulic oil outlet connected to the

hydraulic oil ringline.

875EN115

CJ70-CCR036-E-018-01

CJ70-CCR036-E-007-04

CJ70-CCR036-E-007-02

ST01-M18-J01L-LW-03-00 JACKING LEG WELL AFT, STBD

M-MD-01-30 MAIN DECK, DRAINAGE

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 6 av 12

Unit/Service ST02-M18 Wellhead Utility Station 2 (Standard utility station) remark location loc. Descr. Feed tag connection Drawing

Location Port Side, Aft

Power Supply 690/40 690 VAC 3-phase 60Hz, up to 40A L-LW-02-00 JACKING LEG WELL AFT, PORT 875EN117 ST01-M18-EJ01

Power Supply 690/80 690 VAC 3-phase 60Hz, up to 80A L-LW-02-00 JACKING LEG WELL AFT, PORT 875EN117 ST01-M18-EJ02

Power Supply 230/16 230 VAC 60Hz 16A L-LW-02-00 JACKING LEG WELL AFT, PORT 875EL113.008-X00 875EL113.008-X01 Junction box

Power Supply 230/16 230 VAC 60Hz 16A L-LW-02-00 JACKING LEG WELL AFT, PORT 875EL113.009-X00 875EL113.009-X01 Junction box

Power Supply 230/16 230 VAC 60Hz 16A L-LW-02-00 JACKING LEG WELL AFT, PORT 875EL113.013-X00 875EL113.013-X01 Junction box

Power Supply 230/17 231 VAC 60Hz 16A socket L-LW-02-00 JACKING LEG WELL AFT, PORT 875EL113.019-X00 875EL113.019-X01 STAHL 8570/11-301

16A 6h 2P+PE

Power Supply 230/16 230 VAC 60Hz 16A socket L-LW-02-00 JACKING LEG WELL AFT, PORT 875EL113.020-X00 875EL113.020-X01 STAHL 8570/11-301

16A 6h 2P+PE

Power Supply 230/16 230 VAC 60Hz 16A socket L-LW-02-00 JACKING LEG WELL AFT, PORT 875EL113.021-X00 875EL113.021-X01 STAHL 8570/11-301

16A 6h 2P+PEPhone TL Telephone 2 lines Analog 425-RP-001 Terminal blocksPA PA-A PA/GA-A and PA/GA-B 100V PA/GA - A Terminal blocksPA PA-B PA/GA-A and PA/GA-B 100V PA/GA - B Terminal blocks

Datacomm Lan Fibre optic connection for data communication (LAN connection). Multi mode fibre 423-RQ108 MM / ST

Alarm AL-LEL HC Gas alarm Pot.fre. - NO FS 074 Terminal blocksAlarm AL-H2S H2S Gas alarm Pot.fre. - NO FS 074 Terminal blocksAlarm AL-Fire Fire alarm Pot.fre. - NO FS 074 Terminal blocksAlarm AL-OP Loss of overpressure alarm Pot.fre. - NO FS 074 Terminal blocks

Alarm AL-APS Status signal and shut down signal for UPS’s).

Pot.fre. - NO24V DC - NDE FS 081 Terminal blocks

Plant Air SA-R Plant air with at least 40 meter hose on reel.

Instrument Air IA Instument air connection

Fresh water DW-R Fresh water, with at least 40 meter hose on reel.

HP Washdown HPW-R High-pressure water washing system, 40 meter hose on reel.

Hydraulic Outlet HYD Hydraulic oil outlet connected to the

hydraulic oil ringline.

CJ70-CCR036-E-007-04

CJ70-CCR036-E-007-03

L-LW-02-00 JACKING LEG WELL AFT, PORT CJ70-CCR036-E-019-01

Junction box

ST02-M18-J01

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 7 av 12

Unit/Service ST03-B07 Mud Logging & MWD(Standard utility station) remark location loc. Descr. Feed tag connection Drawing

Location Port side FWD cantilever B deck

Power Supply 690/40 690 VAC 3-phase 60Hz, up to 40A B-UC-07-00

MUD LOGGING CONTAINER AREA, PORT,

FWD, OUTSIDE

875EN111 ST03-B07-EJ01 Junction box

Power Supply 690/80 690 VAC 3-phase 60Hz, up to 80A B-UC-07-00

MUD LOGGING CONTAINER AREA, PORT,

FWD, OUTSIDE

875EN111 ST03-B07-EJ02 Junction box

Power Supply 230/16 230 VAC 60Hz 16A B-UC-07-00

MUD LOGGING CONTAINER AREA, PORT,

FWD, OUTSIDE

570-FX-200.045 570-FX-200.045 STAHL 8570/11-30116A 6h 2P+PE

Power Supply 230/16 230 VAC 60Hz 16A B-UC-07-00

MUD LOGGING CONTAINER AREA, PORT,

FWD, OUTSIDE

570-FX-200.046 570-FX-200.046 STAHL 8570/11-30116A 6h 2P+PE

Phone TL Telephone 2 lines Analog 425-RP-001 Terminal blocksPA PA-A PA/GA-A and PA/GA-B 100V PA/GA - A Terminal blocksPA PA-B PA/GA-A and PA/GA-B 100V PA/GA - B Terminal blocks

Datacomm Lan Fibre optic connection for data communication (LAN connection). Multi mode fibre 423-RQ108 MM / ST

Alarm AL-LEL HC Gas alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-H2S H2S Gas alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-Fire Fire alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-OP Loss of overpressure alarm Pot.fre. - NO FS 073 Terminal blocks

Alarm AL-APS Status signal and shut down signal for UPS’s).

Pot.fre. - NO24V DC - NDE FS 081 Terminal blocks

CCTV CCTV-M CCTV for 3rd party equipment locations including monitors and control pad Hernis 311-JC-101 Terminal blocks

Plant Air SA-R Plant air with at least 40 meter hose on reel.

Instrument Air IA Instument air connection

Fresh water DW-R Fresh water, with at least 40 meter hose on reel.

HP Washdown HPW-R High-pressure water washing system, 40 meter hose on reel.

Hydraulic Outlet HYD Hydraulic oil outlet connected to the

hydraulic oil ringline.Other PW Potable waterOther Drain Drain: 2” connection

CJ70-CCR036-E-007-01

CJ70-CCR036-E-007-04

CJ70-CCR036-E-020-01B-UC-07-00

MUD LOGGING CONTAINER AREA, PORT,

FWD, OUTSIDE

ST03-B07-J01

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 8 av 12

Unit/Service ST04-A05 Mud Treatment Room(Standard utility station) remark location loc. Descr. Feed tag connection Drawing

Location Mid Cantilever Lower Deck

Power Supply 690/40 690 VAC 3-phase 60Hz, up to 40A A-LC-05-00 MUD TREATMENT TANK ROOM 875EN113 ST04-A05-EJ01 Junction box

Power Supply 690/80 690 VAC 3-phase 60Hz, up to 80A A-LC-05-00 MUD TREATMENT TANK ROOM 875EN113 ST04-A05-EJ02 Junction box

Power Supply 230/16 230 VAC 60Hz 16A socket A-LC-05-00 MUD TREATMENT TANK ROOM 570-FX-200.049 570-FX-200.049 875EL111.005-X01

Power Supply 230/16 230 VAC 60Hz 16A socket A-LC-05-00 MUD TREATMENT TANK ROOM 570-FX-200.050 570-FX-200.050 875EL111.006-X01

Phone TL Telephone 2 lines Analog 425-RP-001 Terminal blocksPA PA-A PA/GA-A and PA/GA-B 100V PA/GA - A Terminal blocksPA PA-B PA/GA-A and PA/GA-B 100V PA/GA - B Terminal blocks

Datacomm Lan Fibre optic connection for data communication Multi mode fibre 423-RQ108 MM / ST

Alarm AL-LEL HC Gas alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-H2S H2S Gas alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-Fire Fire alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-OP Loss of overpressure alarm Pot.fre. - NO FS 073 Terminal blocks

Alarm AL-APS Status signal and shut down signal for UPS’s).

Pot.fre. - NO24V DC - NDE FS 081 Terminal blocks

Plant Air SA-R Plant air with at least 40 meter hose on reel.

Instrument Air IA Instument air connection

Fresh water DW-R Fresh water, with at least 40 meter hose on reel.

HP Washdown HPW-R High-pressure water washing system, 40 meter hose on reel.

Hydraulic Outlet HYD Hydraulic oil outlet connected to the

hydraulic oil ringline.

A-LC-05-00 MUD TREATMENT TANK ROOM

CJ70-CCR036-E-007-01

CJ70-CCR036-E-007-04

CJ70-CCR036-E-021-01ST04-A05-J01

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 9 av 12

Unit/Service ST05-M17 ROV (Standard utility station) remark location loc. Descr. Feed tag connection Drawing

Location Main deck port aft

Power Supply 690/40 690 VAC 3-phase 60Hz, up to 40A M-MD-04-30MAIN DECK,

MOORING WINCH, AFT, PORT

875EN119 ST05-M17-EJ01 Junction box

Power Supply 690/80 690 VAC 3-phase 60Hz, up to 80A M-MD-04-30MAIN DECK,

MOORING WINCH, AFT, PORT

875EN119 ST05-M17-EJ02 Junction box

Power Supply 690/350 690 VAC 3-phase 60 HZ M-MD-04-30MAIN DECK,

MOORING WINCH, AFT, PORT

875EN119 ST05-M17-EJ03 Junction box

Power Supply 230/16 230 VAC 60Hz 16A M-MD-04-30MAIN DECK,

MOORING WINCH, AFT, PORT

875EL113.010-X01 875EL113.010-X01 875EL113.010-X01

Power Supply 230/16 230 VAC 60Hz 16A M-MD-04-30MAIN DECK,

MOORING WINCH, AFT, PORT

875EL113.011-X01 875EL113.011-X01 875EL113.011-X01

Phone TL Telephone 2 lines Analog 425-RP-001 Terminal blocksPA PA-A PA/GA-A and PA/GA-B 100V PA/GA - A Terminal blocksPA PA-B PA/GA-A and PA/GA-B 100V PA/GA - B Terminal blocks

Datacomm Lan Fibre optic connection for data communication Multi mode fibre 423-RQ108 MM / ST

Alarm AL-LEL HC Gas alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-H2S H2S Gas alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-Fire Fire alarm Pot.fre. - NO FS 073 Terminal blocksAlarm AL-OP Loss of overpressure alarm Pot.fre. - NO FS 073 Terminal blocks

Alarm AL-APS Status signal and shut down signal for UPS’s).

Pot.fre. - NO24V DC - NDE FS 081 Terminal blocks

Sensor fire/gas Sn-Fire Smoke Detector terminals

CCTV CCTV-M CCTV for 3rd party equipment locations including monitors and control pad Hernis 311-JC-101 Terminal blocks

Plant Air SA-R Plant air with at least 40 meter hose on reel.

Instrument Air IA Instument air connection

Fresh water DW-R Fresh water, with at least 40 meter hose on reel.

HP Washdown HPW-R High-pressure water washing system, 40 meter hose on reel.

Hydraulic Outlet HYD Hydraulic oil outlet connected to the

hydraulic oil ringline.

Unit/Service AU01 Cementing Unit (Additional Utilities) remark location loc. Descr. Feed tag connection Drawing

CJ70-CCR036-E-007-03

CJ70-CCR036-E-007-04

CJ70-CCR036-E-022-01M-MD-04-30MAIN DECK,

MOORING WINCH, AFT, PORT

ST05-M17-J01

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 10 av 12

CCTV CCTV-M CCTV for 3rd party equipment locations including monitors and control pad Hernis 311-JC-101 Terminal blocks

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 11 av 12

Unit/Service JI01-M18 Stbd Aft Jacket Interface Station remark location loc. Descr. Feed tag connection Drawing

Location Main deck stbd aft

PA PA-B PA/GA-A and PA/GA-B 100V L-LW-02-00 JACKING LEG WELL AFT, PORT PA/GA - A / b JI01-M18-J01 Terminal blocks CJ70-CCR076-E-001-01

Plant Air SA-R 1" Reinforced connection immediately above Main Deck c/w Isolation Valve,

Fresh water DW-R 1" Reinforced connection immediately above Main Deck c/w Isolation Valve,

Sea water SW-R 1" Reinforced connection immediately above Main Deck c/w Isolation Valve,

Slop receiver SR-R 3" Reinforced connection immediately above Main Deck c/w Isolation Valve,

Cuttings Injection CI-R 3" Hose for Cuttings Injection 5K

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls

Rev A Date 01.08.2015 Synergi 1140319 side 12 av 12

Unit/Service JI02-M18 Port Aft Jacket Interface Station remark location loc. Descr. Feed tag connection Drawing

Location Main deck port aft

Power Supply 690/125 690 VAC 3-phase 60Hz, up to 125A L-LW-02-00 JACKING LEG WELL AFT, PORT 875EN118 875EN118

warehouse port Junction box CJ70-CCR036-E-007-03

Power Supply 230/32/3 230 VAC 3-phase 60 Hz 32A L-LW-02-00 JACKING LEG WELL AFT, PORT 875EL113.012-X01 875EL113.012-X01 Junction box CJ70-CCR036-E-007-04

PA PA-A PA/GA-A and PA/GA-B 100V PA/GA - A / b Terminal blocksCCTV Camera CCTV-C CCTV Camera Hernis 416RC001 Terminal blocksAlarm KM-LEL HC Gas alarm from platform to VMS Pot.fre. - NO FS 074 Terminal blocksAlarm KM-H2S H2S Gas alarm from platform to VMS Pot.fre. - NO FS 074 Terminal blocksAlarm KM-Fire Fire alarm from platform to VMS Pot.fre. - NO FS 074 Terminal blocks

Alarm AL-APS Status signal and shut down signal for UPS’s).

Pot.fre. - NO24V DC - NDE FS 074 Terminal blocks

Cable for ESD ESD-M ESD to Master valve 24V DC - NDE FS 081 Terminal blocks

Cable for ESD ESD-DHSV ESD to DHSV 24V DC - NDE FS 081 Terminal blocks

UHF UHF UHF Hook up platform

CJ70-CCR076-E-002-01JI02-M18-J01L-LW-02-00 JACKING LEG WELL AFT, PORT

2090-5639194 Utility Stations connections for Temporary equipment West Elara.xls