Mentor Report Weld Inspection / Inspection Instrument Settings Input 1 Time Slot 1 Bridge Mode Receive Gain Drive Voltage BRIDGE 50 22 dB 8 Frequency Selection FA Channel Label Weld Inspection Frequency 100.0 kHz Drive Percentage 100 % Time Slot 2 Bridge Mode Receive Gain Drive Voltage BRIDGE 50 22 dB 8 Frequency Selection Channel Label Frequency Drive Percentage Time Slot 3 Bridge Mode Receive Gain Drive Voltage BRIDGE 50 22 dB 8 Frequency Selection Channel Label Frequency Drive Percentage

Weld Inspection_2015-03-04_23.07.55

Embed Size (px)

DESCRIPTION

Weld Inspection_2015-03-04_23.07.55

Citation preview

Page 1: Weld Inspection_2015-03-04_23.07.55

Mentor Report

Weld Inspection / Inspection

Instrument SettingsInput 1

Tim

e Sl

ot 1

Bridge Mode Receive Gain Drive Voltage

BRIDGE 50 22 dB 8

Frequency Selection FA

Channel Label Weld Inspection

Frequency 100.0 kHz

Drive Percentage 100 %

Tim

e Sl

ot 2

Bridge Mode Receive Gain Drive Voltage

BRIDGE 50 22 dB 8

Frequency Selection

Channel Label

Frequency

Drive Percentage

Tim

e Sl

ot 3

Bridge Mode Receive Gain Drive Voltage

BRIDGE 50 22 dB 8

Frequency Selection

Channel Label

Frequency

Drive Percentage

Page 2: Weld Inspection_2015-03-04_23.07.55

Tim

e Sl

ot 4

Bridge Mode Receive Gain Drive Voltage

BRIDGE 50 22 dB 8

Frequency Selection

Channel Label

Frequency

Drive Percentage

Tim

e Sl

ot 5

Bridge Mode Receive Gain Drive Voltage

BRIDGE 50 22 dB 8

Frequency Selection

Channel Label

Frequency

Drive Percentage

Page 3: Weld Inspection_2015-03-04_23.07.55

Instrument SettingsInput 2

Tim

e Sl

ot 1

Bridge Mode Receive Gain Drive Voltage

BRIDGE 50 22 dB 8

Frequency Selection

Channel Label

Frequency

Drive Percentage

Tim

e Sl

ot 2

Bridge Mode Receive Gain Drive Voltage

BRIDGE 50 22 dB 8

Frequency Selection

Channel Label

Frequency

Drive Percentage

Tim

e Sl

ot 3

Bridge Mode Receive Gain Drive Voltage

BRIDGE 50 22 dB 8

Frequency Selection

Channel Label

Frequency

Drive Percentage

Page 4: Weld Inspection_2015-03-04_23.07.55

Tim

e Sl

ot 4

Bridge Mode Receive Gain Drive Voltage

BRIDGE 50 22 dB 8

Frequency Selection

Channel Label

Frequency

Drive Percentage

Tim

e Sl

ot 5

Bridge Mode Receive Gain Drive Voltage

BRIDGE 50 22 dB 8

Frequency Selection

Channel Label

Frequency

Drive Percentage

Page 5: Weld Inspection_2015-03-04_23.07.55

Panel SettingsAlarm 1 Delay 0.00 sec Alarm 1 Hold 0.50 sec

Alarm 2 Delay 1.00 sec Alarm 2 Hold 0.50 sec

Comparison View File \Data\comparisondata.pkt Comparison Enabled false

Cond Temp Coeff 0.044 Enable Conductivity Probe Measurements false

Conductivity Probe Temp -273 C Shims 1

Shim Thickness 0.0 mm Drive RPM 1000

Sample Rate 1000 Hz Persistence 1.0 sec

Rotary Mode Off Rotary Probe RPM 0

Rotary Sweeps 5 Scan Time (sec) 10.0 sec

Page 6: Weld Inspection_2015-03-04_23.07.55

Channel Label Frequency Gain X Gain Y Phase Filter Selection LP Filter HP Filter

Weld Inspection 100.0 kHz 41.5 dB 41.5 dB 83 deg Band Pass 300.0 Hz 0.0 Hz