33
WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

Embed Size (px)

Citation preview

Page 1: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

1

WELCOME TO THE TECHNICAL PRESENTATION OF SC2000

Page 2: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

2

MICRO RIDE-ON CONCEPT:COMPARISON WITH MEDIUM WALK BEHIND

• New segment of Micro Ride On has appeared on the market

• The speed of Ride On machine is higher than walk behind (6km VS walking speed)

• Ride On design allows more compactness

• Ride On design allows bigger tank capacities (70 L VS 45 L)

• Ride On design allows to stay seat

Page 3: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

3

TECHNICAL SPECIFICATIONSVOLTAGE (V) 24

IP PROTECTION CLASS IP X4

INSULATION CLASS III

RATED POWER (W) in working condition 620

BRUSH MOTOR POWER (W) 450

VACUUM MOTOR POWER (W) 309 / 450

Drive MOTOR POWER (W) 400

VACUUM 1000 mm H2O

SOUND PRESSURE LEVEL (dB(A)) / silent mode 63 / 60

WATER FLOW (cl/min) 0,75 cl/m / 1,5 cl/m / 3,0 cl/m /

2,8 l/min

TANK (L) SOLUTION / RECOVERY 70 / 70

BRUSH PRESSURE (KG) normal / extra-pressure 15 / 30

BRUSH SPEED (RPM) 155

BRUSH SIZE (MM) 530

Page 4: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

4

CONTROL PANEL

Grey Operator key - start display

Page 5: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

5

SETTINGS EFFECTIVELY CONTROLLED

Grey Operator key start displayNo changing of settings only basiccontrolled by the Superuser key.

Yellow Superuser key start display

To operate the machine with Superuser key press Work

To enter each setting press parameters settings

Page 6: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

6

SETTINGS Yellow Superuser key settingsMODIFIABLE PARAMETERS

Code Description Min. Value Factory Setting Max. Value

CHM1 Detergent concentration level 1 1:500 (0.25 %) 1:500 (0.25 %) 1:33 (3 %)

CHM2 Detergent concentration level 2 1:500 (0.25 %) 1:125 (0.80 %) 1:33 (3 %)

P1/P3Level 1 solution flow rate in relation to level 3(see section “System for Flow Rate Regulation as Function of Speed”)

0 % 25 % 100 %

P2/P3Level 2 solution flow rate in relation to level 3(see section “System for Flow Rate Regulation as Function of Speed”)

0 % 50 % 100 %

P3 Level 3 solution flow rate

DISC 1.0 cl/m 3.0 cl/m 5.0 cl/m

REV™ 1.0 cl/m 1.5 cl/m 5.0 cl/m

P4 Level 4 solution flow enable OFF OFF ON

SPT EcoFlex™ function timer 0 (disabled) 60 sec. 300 sec.

XPRES Brush deck extra pressure enable OFF ON ON

FVMIN Minimum forward speed 0 % 25 % 100 %

FVMAX Maximum forward speed 10 % 100 % 100 %

RVMAX Maximum reverse speed 10 % 30 % 50 %

BAT Installed battery type 0 1 5

TOFF Automatic shut-off time 0 (disabled) 300 sec. 600 sec.

BRGH Display contrast 5 20 50

VRID Vacuum power in silent mode 1 1 5

RPM (*) Reduced brush rpm activation threshold 5 9 20

RESET Restore factory settings for all parameters OFF OFF ON

Page 7: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

7

SETTINGS Yellow Superuser key settingsHIDDEN PARAMETERS

Code Description Min. Value Factory Setting Max. Value

Meaning

TSERV Service advisory timer 0 0 1000

Set to a value X greater than 0 if you wish the “Service Advisory” icon to be displayed every X hours of machine running time (according to the main operating time counter). To reset the hour counter for the icon display countdown (until the next service advisory), press the BURST and vacuum buttons for 10 seconds with the display on the “SERVICE MENU” page.

ARMaximum acceleration ramp (sec.)

0.5 sec. 1.5 sec. 5 sec. Increase to obtain a less abrupt response when accelerating, and vice versa.

DRMaximum deceleration ramp (sec.)

DISC 0.5 sec. 1.5 sec. 8 sec.Increase to obtain a less abrupt response when decelerating, and vice versa.WARNING: increasing this value increases the braking distance.

REV™ 0.5 sec. 2.5 sec. 8 sec.

IRMaximum deceleration ramp in reverse (sec.)

0.5 sec. 0.5 sec. 5 sec.This is the maximum current which can be supplied to the disc brush deck.WARNING: increasing this value increases the risk of the motors overheating.

VS1Brush 1 motor protection threshold

20A 30A 50AThis is the maximum current which can be supplied to the disc brush deck.WARNING: increasing this value increases the risk of the motors overheating.

VS2Brush 2 motor protection threshold

20A 40A 50AThis is the maximum current which can be supplied to the cylindrical brush deck.WARNING: increasing this value increases the risk of the motors overheating.

VDEADPaddle potentiometer dead zone

0.0V 0.1V 1.0VIncrease if the alarm T3 appears in the rest position and it is not possible to adjust the system’s mechanics. (Speed regulation will, however, be more difficult to modulate)

INOM Nominal drive current 10A 15A 15AThis is the maximum continuous current which can be supplied to the electric wheel drive unit.WARNING: increasing this value increases the risk of the motor overheating.

IMAX Maximum drive current 10A 45A 45AThis is the maximum instantaneous current which can be supplied to the electric wheel drive unit.WARNING: increasing this value increases the risk of the motor overheating.

TMAX Protection trip time for IMAX 0 sec. 12 sec. 60 sec.This is the reaction time of the electric wheel drive unit protection device when overloaded: this parameter is used in conjunction with IMAX to obtain the most appropriate response curve for the overload protection motor actuation system.WARNING: increasing this value increases the risk of the motor overheating.

Page 8: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

8

SERVICE MENU

YELLOW key – Super User

Key include magnet inside:

• grey key (1 magnet) = switch machine ON

• Yellow (2 magnet) = enter to service mode

To adjust:

speed +

speed -

Voltage to EB2 sensor

Key

> 2,45 Key issue

2,18 – 2,45 Grey

1,23 – 2,18 Yellow

< 1,23 PCB sensor issue

Page 9: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

9

HOUR METER Cumulated running time for each motor:

• Key ON

• Traction motor

• Brush motor

• Vac motor

Running time reset:

keep pressed for 10sec +

• Total• Traction motor• Brush motor• Vac motor

Page 10: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

ERROR CODES

Errors are shown on display

by ALARM XX + description

& repeated

On the main PCB (EB1)

by Nr of LED RED blinking

(useful in case the display

not functioning)

10

Page 11: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

DRIVE SYSTEM ERROR CODE (ALARM)

T - Drive system alarms

G - General Alarms

F - Function Alarms

Allarmi sistema trazione (LDC)Codice

allarme= N° lampeggi

Significato Condizione

T2 Current cutoff on traction transaxle I > INOM per t > tprot

T3 Pedal input activated Reset machine

T4 Pedal defective J1.11 > 6,0V

T5 Traction output MOSFET malfunction

CC MOSFET

T6 Overcurrent Traction motor I > 1,5 * IMAX

T7 Over temperature Traction controller Temp. > 90°C

T8 Electro brake malfunction Impedence J4.3 – J4.8 > 1kΩ

11

Page 12: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

12

SOLUTION FLOW RATE SETTING

SC2000 solution flow is controlled by the speed.Always the same amount of solution on the floorregardless of machine speed.3 standard settings and number 4 as optionLevel 3: 3cl/m Level 2: 50% of level 3 giving 1,5cl/mLevel 1: 25% of level 3 giving 0,75cl/m

Superuser key can activate level 4 and change all other levels if neededLevel 4: 2,8 L/min full valve open, not controlled by speed. More used as problem solver or for double scrubbing

Water off Level 1 Level 2 Level 3 Level 4

Standard settings Option

Solution calculation

Page 13: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

WATER ONLYULTRA-LOW DETERGENT CONCENTRATIONINTERMITTENT “BURST OF POWER” (60 SECONDS)FULL-STRENGTH DETERGENT

“BURST OF POWER” TEMPORARILY INCREASES WATER FLOW, BRUSH PRESSURE AND DETERGENT STRENGTH FOR 60 SECONDS

Page 14: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

ECOFLEX PURGE

Switch on and keep pressed: +

The pump run one cycle of 30 sec to flush the detergent residual

14

Page 15: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

15

CHASSIS SYSTEM• Transaxle• Drive wheels• Brush deck support levers• Squeegee support

Page 16: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

16

BRUSH MOTOR & VAC MOTOR

Brush motor controlled by amp consumption.To avoid the brush motor rpm to get too high in light application the machine monitors and adjust by lowering the power to the motor if the amp consumption is less than 9 amps. (this can also be changed with Superuser key) Lower energy consumption Less risk for splashing Less stress of the surface due to lower rpm

Vac motor silent mode optionWith the silent mode option the power to the vacuum motor is reduced still giving enough suction on a normal even floor in lower water settings.Not recommended in level 3 or 4 Lower energy consumption Lower sound level Enable cleaning in sound sensitive areas

In all the following features is giving in light cleaningapplication with a light brush or pad and machine working in silent mode a low energy consumptionand long running time. Up to 4 hours running time.

Running time calculator

Page 17: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

BRUSH DECK SYSTEM

Brush motor supply voltage controlled by EB1 depending on the load:• 24V when consumption is > 9 amps. • 20V when consumption is < 9 amps. (adjustable by

Superuser key)

Brush motor rpm reduction advantage in light application:• Less water splashing• Less noise• Less stress of the surface due to lower rpm• Lower energy consumption

17

Page 18: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

BRUSH MOTOR ELECTRICAL INPUT CHECK

Apply an ammeter on the cable,

Check the motor electrical input is 3

to 4 Amps @ 20 V (without load)

Supplier - AMER

• Motor 450W @ 2800 rpm

• IP20

18

Page 19: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

SQUEEGEE ACTUATOR 2 position actuator:

Step 0 = retracted - mechanical end of stroke

Step1 = extended -

• No adjustment required

• Max thrust load: 100 N equal to 10 Kg

• Speed: 16mm/Sec

• Full load current 3,5 A Amps

• IP44

19

Page 20: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

BRUSH DECK ACTUATOR

3 position actuator:

Step 0 = retracted - mechanical end of stroke

Step1 = intermediate - 85 mm (green LED) electronically adjusted

Step2 = extended - 120mm (red LED) mechanical end of stroke

• No adjustment required

• Max thrust load: 300 N

• Speed: 16mm/Sec

• No load current AMPS MAX:1A/24

• Full load current AMPS: 4A/24

• IP44

20

Page 21: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

21

DRIVE MOTOR TECHNICAL SPECIFICATIONS DRIVE MOTOR:- MOTOR POWER: 400W- TENSION: 24V- DUTY: 20A S2 60 sec- WITHOUT LOAD 3A- GEAR RATIO: 26/1- PROTECTION: IP44- INSULATION CLASS: F- MAX LOAD ON AXES: 300 Kg- RPM SHAFT: 125

Page 22: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

VACUUM SYSTEM

No carbon brush replacement

Apply an ammeter on the cable Check the motor electrical input is 25 Amps @ 24 V .

Max peak 35 Amps for 10 sec.

Check the gasket

condition and correct

assembly sequence to

secure the proper

sealing

22

Page 23: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

23

VACUUM SYSTEM

VAC motorIs assembled into sound isolated box

standardMOTOR VACUUM 24V 310W

OptionMOTOR VACUUM 24V 450W

Low noise Vac motor system Sound insulated vac motor box inside the tank Silent mode setting from dashboard

Page 24: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

VAC motor supply voltage controlled by EB1 depending

on silent mode selection:

Vac motor rpm reduction advantage in light application:

• Lower sound level

• Enable cleaning in sound sensitive areas

• Lower energy consumption

VAC MOTOR SILENT MODE

Set parameter VRID

Vac motor voltage

1 (default) 16V2 17V3 18V4 19V5 20V

24

Page 25: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

25

SQUEEGEE SYSTEM

No hose removal neededHose connected to squeegee support

Patent elastic strap systemStandard PU blades higher wear resistant

Optional blades• Red gum • Standard Gum

Page 26: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

26

BATTERY & ONBOARD CHARGER

Option on-board charger

• SPE Model: CBHD1-XR

• 24V - 13Amp high frequency

• Input: 85÷264 Vac, 50÷60 Hz

• PROTECTION GRADE: IP 30

• Protection: against polarity inversion, short circuits, over-voltages, anomalies and thermal protection against overheating

Option BATTERYPN Use per

machineDescription

80564600 2 BATT.12V-110Ah WET Tubular Monobloc

80564700 2 BATT.12V-72Ah WET Tubular Monobloc

80564400 2 BATT.12V-105Ah GEL Monobloc

80564310 2 BATT.12V-76Ah GEL Monobloc

80561268 2 BATT.12V-68Ah AGM spiralcell

Max runtime up to 6/7h

Machine overall consumption 11/12

amps (on smooth floor and silent mode)

Page 27: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

27

BATTERY & CHARGER CURVE SELECTION

Type of battery valueWET 0GEL / AGM generic 1GEL EXIDE®/SONNENSHINE 2GEL OPTIMA™ 3GEL DISCOVER® 4GEL FULLRIVER® 5

By the PARAMETER SETTINGS on control panel

WET GEL (maintenance free)

1 22 V 22,2 V LOW batt message

2 20,4 V 21,6 V OFF brush

3 19,4 V 20,6 V OFF VAC

4 18,4 V 19,6 V OFF drive

DEFAULT CHARGING CURVES: GEL / AGM generic (1)

Voltage cut-off threshold

Page 28: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

28

CHARGER ERROR

GB-NTime of continuous use with discharged batteries

N= nr of hours machine ON with battery level below 20,4 (wet) or 21,6 (gel)

GC Charging cycle interrupted before completion OBC disconnected before the phase IV

GD-N Charging phase duration (<4h) N= nr of hours from start to phase II (if < 4h)

ERROR DESCRIPTION

C1 CHARGER COMMUNICATION

C2 BATTERY OVERVOLTAGE

C3 CHARGER OVERTEMP

C4 PHASE I TIME EXPIRED

C5 PHASE II TIME EXPIRED

C6 CHARGER FAULT

Event memorized in ALARM LOG related to improper use of battery and/or battery charger:

Page 29: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

MAIN BOARD (EB1)

Drive motor (M3)

F2 – low power fuse (3A)

F1 - Main fuse (100A)Inside PCB cover

Vac motor (M2)

Battery connection

Brush motor (M1)

29

Page 30: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

MAIN BOARD (EB1)

J1 – Detergent pump (M4) Deck actuator (M5)

J3 – connection to EB2

J4 – OBC communication

J6 – ECOflex configuration: jumper on – ecoflex disabled

J7 – trackclean

J5 – solution level sensor

J2 – solenoid valve (EV1)

30

Page 31: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

31

ACCESSORIES

• Waste or accessory basket

• Mop holder

Water filling kit with automatic shut offwhen full, ½ inch Gardena male.Female not included.

9100000663 BEACON FLASHING KIT

9100000688 SUPPORT MOP KIT

9100000694 ECOFLEX CHEMICAL KIT SC2000

9100000697 BASKET KIT

9100000707 AUTOMATIC WATER FILLING KIT

9100000784 USB PORT KIT

9100000952 FILLING HOSE

9100000810 BLADE SQUEEGEE 740MM 29 GUM KIT

9100000060 BLADE SQUEEGEE 740MM 29 RED GUM KIT

9100000490 BLADE SQUEEGEE 740MM 29 PU KIT

9099826000 SPLASHGUARD 510MM 20 KIT

9100000491 HIGH POWER VACUUM MOTOR 24V 450W KIT

909 5065 000 FILTER ANTIFOAMING

Page 32: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

32

THANKS FOR YOUR ATTENTION

Page 33: WELCOME TO THE TECHNICAL PRESENTATION OF SC2000 1

QUESTION & COMMENTS LIST

33