Upload
massaco
View
117
Download
0
Embed Size (px)
Citation preview
96
2
1
B
A
4
3
6
5
3
2
A Sleeping recess in wall
B Horizontal section through south facade
C Vertical section through south facade
scale 1:10
1 0.4 mm aluminium-coated, galvanized
sheet-steel welted-seam roof covering
bituminous sealing layer
9 mm laminated lauan sheeting
100 mm mineral-wool insulation between
90/120 mm rafters
vapour barrier
battens
9.5 mm plasterboard, painted white
2 15 mm lapped cedar boarding
bituminous sealing layer
50 mm mineral-wool insulation
9 mm lauan plywood
3 condensation channel
4 ventilation flap
5 sliding element with insect screen
6 5.5 mm laminated lauan sheeting
12 mm plywood
30 mm polystyrene insulation between
45/60 mm battens
100/150 mm timber joists