Sample Inspection Report
742 Evergreen Terrace Springfield, OH 44224
Prepared for: Homer and Marge Simpson
Prepared by: Apex Inspection Services, LLC1700 West Market StreetAkron, OH [email protected]
Table of Contents
Definitions 2
General Information 2
Lots and Grounds 3
Exterior Surface and Components 4
Roof 6
Garage/Carport 8
Electrical 9
Structure 10
Attic 11
Basement 12
Air Conditioning 14
Fireplace/Wood Stove 14
Heating System 15
Plumbing 16
Bathroom 17
Kitchen 18
Bedroom 18
Living Space 20
Laundry Room/Area 21
Summary 22
Apex Inspection Services, LLC742 Evergreen Terrace Page 1 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
DefinitionsNOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection
Acceptable Functional with no obvious signs of defect. Not Present Item not present or not found. Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or
disconnected at time of inspection. Marginal Item is not fully functional and requires repair or servicing. Defective Item needs immediate repair or replacement. It is unable to perform its intended function.
General Information
Property Information
Property Address 742 Evergreen Terrace
City Springfield State OH Zip 44224
Contact Name Phone Fax
Client Information
Client Name Homer and Marge Simpson
Client Address 742 Evergreen Terrace
City Springfield State OH Zip 44224
Phone 999-999-9999 Fax
Inspection Company
Inspector Name Tom Carano
Company Name Apex Inspection Services, LLC
Address 1700 West Market Street
City Akron State OH Zip 44313
Phone 330-922-5730 Fax 330-940-3595
E-Mail [email protected]
File Number 1110
Amount Received $275.00
Conditions
Others Present Buyer Property Occupied Occupied
Estimated Age 51 years Entrance Faces West
Inspection Date 11/13/2011
Start Time 12:00 PM End Time 3:30 PM
Electric On Yes
Gas/Oil On Yes
Water On Yes
Temperature 60 degrees
Weather Cloudy Soil Conditions Damp
Space Below Grade Basement
Apex Inspection Services, LLC742 Evergreen Terrace Page 2 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
General Information (Continued)Building Type Single family Garage Attached garage
Sewage Disposal City How Verified Visual Inspection
Water Source City How Verified Visual Inspection
Additions/Modifications Unknown
Permits Obtained Unknown
Lots and GroundsAcceptable Driveway: Concrete, Asphalt
Acceptable Walks: Epoxy/stone material
Acceptable Steps/Stoops: Epoxy/stone material
Acceptable Porch: Epoxy/stone material
Acceptable Patio: Gravel
Acceptable Deck: Stained wood
Acceptable Grading: Minor slope
Acceptable Vegetation: Trees, Shrubs
Apex Inspection Services, LLC742 Evergreen Terrace Page 3 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Lots and Grounds (Continued)Acceptable Window Wells: Drain not present
Acceptable Fences: Chain link
Exterior Surface and Components Whole building Exterior Surface Acceptable Type: Aluminum siding
Acceptable Trim: Aluminum
Acceptable Fascia: Aluminum
Acceptable Soffits: Aluminum - Loose
Acceptable Door Bell: Front door
Apex Inspection Services, LLC742 Evergreen Terrace Page 4 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Exterior Surface and Components (Continued)Acceptable Entry Doors: Metal, Glass slider - Add closing mechanism to entry door
Acceptable Patio Door: Metal entry door
Acceptable Windows: Vinyl double hung, Vinyl slider
Acceptable Window Screens: Vinyl mesh
Acceptable Basement Windows: Vinyl slider, Steel casement
Acceptable Exterior Lighting: Surface mounted lamps front and rear
Acceptable Hose Bibs: Rotary
Apex Inspection Services, LLC742 Evergreen Terrace Page 5 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Exterior Surface and Components (Continued)Acceptable Gas Meter: Basement
Acceptable Main Gas Valve: Located at gas meter
Roof Main Roof Surface Method of Inspection: On roof
Acceptable Material: Asphalt shingle - Moss growing on shingles
Type: Gable
Approximate Age: 10-15 years
Acceptable Flashing: Aluminum
Acceptable Plumbing Vents: PVC, Cast Iron
Apex Inspection Services, LLC742 Evergreen Terrace Page 6 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Roof (Continued)Marginal Gutters: Aluminum - Damaged
Acceptable Downspouts: Aluminum
Acceptable Leader/Extension: Hooked into storm drain - A qualified contractor is recommended to check underground drain tiles for damage or clogs
South Chimney
Apex Inspection Services, LLC742 Evergreen Terrace Page 7 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Roof (Continued)Acceptable Chimney: Brick
Not Inspected Flue/Flue Cap: Unable to view due to caps - A qualified contractor is recommended to evaluate
Acceptable Chimney Flashing: Aluminum
North Chimney Acceptable Chimney: Brick
Not Inspected Flue/Flue Cap: Unable to view due to caps - A qualified contractor is recommended to evaluate
Acceptable Chimney Flashing: Aluminum
Garage/Carport Attached Garage Type of Structure: Attached Car Spaces: 2
Acceptable Garage Doors: Insulated aluminum
Acceptable Door Operation: Mechanized
Acceptable Door Opener: Genie
Apex Inspection Services, LLC742 Evergreen Terrace Page 8 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Garage/Carport (Continued)Acceptable Exterior Surface: Aluminum siding
Acceptable Roof: Asphalt shingle
Acceptable Roof Structure: 2x8 Rafter
Acceptable Service Doors: Metal
Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Finished drywall
Acceptable Floor/Foundation: Poured slab - Minor cracks in floor, No displacement
Acceptable Hose Bibs: Rotary
Acceptable Electrical: 110 VAC outlets and lighting circuits
Acceptable Windows: Vinyl slider
Acceptable Gutters: Aluminum
Acceptable Downspouts: Aluminum
Acceptable Leader/Extensions: Hooked into storm drain - A qualified contractor is recommended to check underground drain tiles for damage or clogs
ElectricalService Size Amps: 100 Volts: 110-240 VAC
Acceptable Service: Aluminum
Acceptable 120 VAC Branch Circuits: Copper
Acceptable 240 VAC Branch Circuits: Copper
Acceptable Conductor Type: Romex
Acceptable Ground: Rod in ground only
Apex Inspection Services, LLC742 Evergreen Terrace Page 9 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Electrical (Continued) Garage Electric Panel Acceptable Manufacturer: Square D
Maximum Capacity: 100 Amps
Acceptable Main Breaker Size: 2 - 50 Amp
Acceptable Breakers: Copper and Aluminum
Is the panel bonded? Yes
StructureAcceptable Structure Type: Wood frame
Acceptable Foundation: Block
Marginal Differential Movement: Stair step crack with displacement - Some movement in wall noted, Repairs have been made
Acceptable Beams: Steel I-Beam
Acceptable Bearing Walls: Block, Frame
Acceptable Joists/Trusses: 2x6, 2x8
Acceptable Piers/Posts: Steel posts
Acceptable Floor/Slab: Poured slab
Acceptable Stairs/Handrails: Wood stairs with wood handrails
Not Inspected Subfloor: Unable to inspect subfloor due to carpet or floor coverings
Apex Inspection Services, LLC742 Evergreen Terrace Page 10 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Attic South Attic Method of Inspection: In the attic
Acceptable Roof Framing: 2x8 Rafter
Acceptable Ventilation: Ridge and soffit vents
Acceptable Insulation: Batts
Acceptable Insulation Depth: 6"
Defective Bathroom Fan Venting: Electric fan - Bathroom improperly vents into attic and may cause moisture damage to the insulation or framing
North Attic Method of Inspection: In the attic
Acceptable Roof Framing: 2x8 Rafter
Acceptable Sheathing: Plywood
Acceptable Ventilation: Ridge and soffit vents
Acceptable Insulation: Batts
Acceptable Insulation Depth: 6"
Defective Wiring/Lighting: 110 VAC lighting circuit - Open junction boxes, Exposed wiring is energized
Apex Inspection Services, LLC742 Evergreen Terrace Page 11 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Basement Sub-basement Basement Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Painted drywall
Acceptable Floor: Carpet - Floor shows evidence of previous water penetration/stains
Acceptable Floor Drain: Surface drain
Acceptable Doors: Bi-fold
Marginal Electrical: 110 VAC outlets and lighting circuits - Open ground, A licensed electrician is recommended to evaluate and estimate repairs
Not Inspected Vapor Barrier: Finished basement, unable to determine if a vapor barrier is present
Not Inspected Insulation: Finished basement, unable to determine if walls are insulated.
Acceptable Sump Pump: Submerged
Marginal Moisture Location: Northwest corner
Apex Inspection Services, LLC742 Evergreen Terrace Page 12 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Basement (Continued)Acceptable Basement Stairs/Railings: Carpeted stairs with wood railings
Main Basement Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Paneling
Acceptable Floor: Carpet
Acceptable Doors: Hollow wood
Acceptable Windows: Vinyl casement
Marginal Electrical: 110 VAC outlets and lighting circuits - Open ground, A licensed electrician is recommended to evaluate and estimate repairs
Acceptable HVAC Source: Heating system register
Not Inspected Vapor Barrier: Finished basement, unable to determine if a vapor barrier is present
Not Inspected Insulation: Finished basement, unable to determine if walls are insulated.
Acceptable Ventilation: Windows
Acceptable Basement Stairs/Railings: Carpeted stairs with wood railings
Apex Inspection Services, LLC742 Evergreen Terrace Page 13 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Air Conditioning Main AC System Acceptable A/C System Operation: Functional
Acceptable Condensate Removal: PVC
Acceptable Exterior Unit: Pad mounted
Manufacturer: Payne
Model Number: PA13NR036-H Serial Number: 2509X73762
Area Served: Whole building Approximate Age: 2 years
Fuel Type: 208-230 VAC Temperature Differential: 10 degrees
Type: Central A/C Capacity: 3 Ton
Acceptable Visible Coil: Copper core with aluminum fins
Acceptable Refrigerant Lines: High pressure
Acceptable Electrical Disconnect: Fused
Acceptable Exposed Ductwork: Metal
Acceptable Blower Fan/Filters: Direct drive with disposable filter
Acceptable Thermostats: Programmable
Fireplace/Wood Stove Basement Fireplace Acceptable Fireplace Construction: Brick
Type: Wood burning
Acceptable Smoke Chamber: Brick
Not Inspected Flue: A qualified contractor is recommended to inspect flue
Apex Inspection Services, LLC742 Evergreen Terrace Page 14 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Fireplace/Wood Stove (Continued)Acceptable Damper: Metal
Acceptable Hearth: Raised
Heating System Basement Heating System Acceptable Heating System Operation: Appears functional
Manufacturer: Bryant
Model Number: 330AAV048100 Serial Number: 3594A14849
Type: Forced air Capacity: 80,000 BTU
Area Served: Whole building Approximate Age: 17 years
Fuel Type: Natural gas
Acceptable Heat Exchanger: 5 Burner - No carbon monoxide detected using electronic CO detector
Acceptable Blower Fan/Filter: Direct drive with electronic filter
Acceptable Distribution: Metal duct
Acceptable Flue Pipe: Double wall
Acceptable Controls: Manual shutoff located on unit
Acceptable Humidifier: April-Aire
Acceptable Thermostats: Programmable
Suspected Asbestos: No
Apex Inspection Services, LLC742 Evergreen Terrace Page 15 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
PlumbingAcceptable Service Line: Copper
Acceptable Main Water Shutoff: Basement
Acceptable Water Lines: Copper
Acceptable Drain Pipes: Cast iron
Acceptable Service Caps: Accessible
Acceptable Vent Pipes: Cast iron
Acceptable Gas Service Lines: Cast iron
Basement Water Heater Acceptable Water Heater Operation: Functional at time of inspection
Manufacturer: Rheem
Model Number: 22V40F1 Serial Number: RHLN0407413549
Type: Natural gas Capacity: 40 gallons
Approximate Age: 4 years Area Served: Whole building
Acceptable Flue Pipe: Single wall - No carbon monoxide detected using electronic CO detector
Marginal TPRV and Drain Tube: Copper - Drain tube opening is not within six inches of the floor, Could pose a scalding hazard
Apex Inspection Services, LLC742 Evergreen Terrace Page 16 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Plumbing (Continued)
Bathroom Basement Bathroom Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Painted drywall
Acceptable Floor: Tile
Acceptable Doors: Wood
Marginal Electrical: 110 VAC outlets and lighting circuits - Non-GFCI circuit, Recommend GFCI circuit be installed
Acceptable Counter/Cabinet: Laminate and wood
Acceptable Sink/Basin: Synthetic
Acceptable Faucets/Traps: Moen fixtures with a metal trap
Acceptable Shower/Surround: Fiberglass pan and ceramic tile surround
Acceptable Toilets: Kohler, 1 1/2 gallon tank
Acceptable HVAC Source: Heating system register
Acceptable Ventilation: Electric ventilation fan
2nd floor Bathroom Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Painted drywall
Acceptable Floor: Tile
Acceptable Doors: Hollow wood
Marginal Electrical: 110 VAC GFCI, 110 VAC lighting circuit - Open or missing ground, Non-GFCI outlet controlled by GFCI outlet
Acceptable Counter/Cabinet: Wood
Acceptable Sink/Basin: Porcelain
Acceptable Faucets/Traps: Moen fixtures with a metal trap
Acceptable Tub/Surround: Fiberglass tub and fiberglass surround
Acceptable Shower/Surround: Integrated with bathtub
Acceptable Toilets: Kohler, 1 1/2 gallon tank
Acceptable HVAC Source: Heating system register
Acceptable Ventilation: Electric ventilation fan
Apex Inspection Services, LLC742 Evergreen Terrace Page 17 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Kitchen 1st Floor Kitchen Not Inspected Cooking Appliances: Maytag
Not Inspected Ventilator: General Electric
Not Inspected Disposal: In-Sinkerator
Not Inspected Dishwasher: LG
Air Gap Present? Yes
Not Inspected Refrigerator: General Electric
Not Inspected Microwave: General Electric
Acceptable Sink: Stainless Steel
Marginal Electrical: 110 VAC outlets and lighting circuits - Non-GFCI circuit, Recommend GFCI circuit be installed
Acceptable Plumbing/Fixtures: PVC
Acceptable Counter Tops: Synthetic material
Acceptable Cabinets: Laminate and wood
Acceptable Pantry: Large
Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Painted drywall
Acceptable Floor: Tile
Acceptable Doors: Metal door
Acceptable Windows: Vinyl double hung
Acceptable HVAC Source: Heating system register
Bedroom Basement Bedroom Acceptable Walls: Painted drywall
Acceptable Ceiling: Finished and textured drywall
Not Inspected Telephone Jack: Acceptable Closet: Finsished drywall
Acceptable Floor: Carpet
Acceptable Doors: Hollow wood
Acceptable Windows: Vinyl slider
Acceptable Electrical: 110 VAC outlets and lighting circuits
Acceptable HVAC Source: Heating system register
Not Inspected Television Connection: 2nd Floor Master Bedroom Acceptable Walls: Painted drywall
Acceptable Ceiling: Finished and textured drywall
Not Inspected Telephone Jack: Acceptable Closet: Double
Acceptable Floor: Hardwood
Acceptable Doors: Hollow wood
Acceptable Windows: Vinyl slider
Marginal Electrical: 110 VAC outlets and lighting circuits - Open or missing ground, Closet
Apex Inspection Services, LLC742 Evergreen Terrace Page 18 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Bedroom (Continued)Acceptable HVAC Source: Heating system register
Not Inspected Television Connection: Southwest corner Bedroom Acceptable Walls: Painted drywall
Acceptable Ceiling: Finished and textured drywall
Not Inspected Telephone Jack: Acceptable Closet: Single
Acceptable Floor: Hardwood
Acceptable Doors: Hollow wood
Acceptable Windows: Vinyl slider
Marginal Electrical: 110 VAC outlets and lighting circuits - Reversed polarity
Acceptable HVAC Source: Heating system register
Not Inspected Television Connection: West Bedroom Acceptable Walls: Painted drywall
Acceptable Ceiling: Finished and textured drywall
Not Inspected Telephone Jack: Acceptable Closet: Single
Acceptable Floor: Hardwood
Acceptable Doors: Hollow wood
Acceptable Windows: Vinyl slider
Acceptable Electrical: 110 VAC outlets and lighting circuits
Acceptable HVAC Source: Heating system register
Not Inspected Television Connection:
Apex Inspection Services, LLC742 Evergreen Terrace Page 19 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Living Space Family Room, Basement Living Space Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Paneling
Acceptable Floor: Carpet
Acceptable Doors: Metal door
Acceptable Windows: Vinyl slider
Marginal Electrical: 110 VAC outlets and lighting circuits - Open or missing ground, A licensed electrician is recommended to evaluate and estimate repairs
Acceptable HVAC Source: Heating system register
Office, Basement Living Space Acceptable Closet: Single
Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Painted drywall
Acceptable Floor: Carpet
Acceptable Doors: Hollow wood
Acceptable Windows: Vinyl slider
Acceptable Electrical: 110 VAC outlets and lighting circuits
Acceptable HVAC Source: Heating system register
Living Room Living Space Acceptable Closet: Single
Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Painted drywall
Acceptable Floor: Hardwood
Acceptable Doors: Metal door
Acceptable Windows: Wood double hung
Acceptable Electrical: 110 VAC outlets and lighting circuits
Acceptable HVAC Source: Heating system register
2nd Floor Hall Living Space Acceptable Closet: Small
Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Painted drywall
Acceptable Floor: Hardwood
Acceptable Doors: Hollow wood
Acceptable Electrical: 110 VAC
Acceptable HVAC Source: No direct heating
Dining Room Living Space Acceptable Ceiling: Finished and textured drywall
Acceptable Walls: Painted drywall
Acceptable Floor: Hardwood
Acceptable Doors: Sliding glass
Apex Inspection Services, LLC742 Evergreen Terrace Page 20 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Living Space (Continued)Marginal Electrical: 110 VAC - Open or missing ground, A licensed electrician is recommended to evaluate and
estimate repairs
Acceptable HVAC Source: Heating system register
Laundry Room/Area Sub-basement Laundry Room/Area Acceptable Ceiling: Exposed framing
Acceptable Walls: Concrete block
Acceptable Floor: Poured concrete
Acceptable Windows: Steel casement
Acceptable Electrical: 110 VAC outlets and lighting circuits
Acceptable Laundry Tub: PVC
Acceptable Laundry Tub Drain: PVC
Acceptable Washer Hose Bib: Rotary
Acceptable Washer and Dryer Electrical: 110-120 VAC
Acceptable Dryer Vent: Rigid metal
Acceptable Dryer Gas Line: Insulflex
Acceptable Washer Drain: Drains to laundry tub
Acceptable Floor Drain: Surface drain
Apex Inspection Services, LLC742 Evergreen Terrace Page 21 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Summary
Roof
1. Gutters: Aluminum - Damaged
Structure
2. Differential Movement: Stair step crack with displacement - Some movement in wall noted, Repairs have been made
Attic
3. South Attic Bathroom Fan Venting: Electric fan - Bathroom improperly vents into attic and may cause moisture damage to the insulation or framing
Apex Inspection Services, LLC742 Evergreen Terrace Page 22 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Summary (Continued) Summary (Continued)4. North Attic Wiring/Lighting: 110 VAC lighting circuit - Open junction
boxes, Exposed wiring is energized
Basement
5. Sub-basement Basement Electrical: 110 VAC outlets and lighting circuits - Open ground, A licensed electrician is recommended to evaluate and estimate repairs
6. Sub-basement Basement Moisture Location: Northwest corner
7. Main Basement Electrical: 110 VAC outlets and lighting circuits - Open ground, A licensed electrician is recommended to evaluate and estimate repairs
Apex Inspection Services, LLC742 Evergreen Terrace Page 23 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Basement (Continued)Electrical: (continued)
Plumbing
8. Basement Water Heater TPRV and Drain Tube: Copper - Drain tube opening is not within six inches of the floor, Could pose a scalding hazard
Bathroom
9. Basement Bathroom Electrical: 110 VAC outlets and lighting circuits - Non-GFCI circuit, Recommend GFCI circuit be installed
10. 2nd floor Bathroom Electrical: 110 VAC GFCI, 110 VAC lighting circuit - Open or missing ground, Non-GFCI outlet controlled by GFCI outlet
Kitchen
11. 1st Floor Kitchen Electrical: 110 VAC outlets and lighting circuits - Non-GFCI circuit, Recommend GFCI circuit be installed
Bedroom
12. 2nd Floor Master Bedroom Electrical: 110 VAC outlets and lighting circuits - Open or missing ground, Closet
Apex Inspection Services, LLC742 Evergreen Terrace Page 24 of 25
Palm-Tech Inspector, Copyright © 1998-2012, PDmB, Inc.
Summary (Continued) Summary (Continued)13. Southwest corner Bedroom Electrical: 110 VAC outlets and lighting
circuits - Reversed polarity
Living Space
14. Family Room, Basement Living Space Electrical: 110 VAC outlets and lighting circuits - Open or missing ground, A licensed electrician is recommended to evaluate and estimate repairs
15. Dining Room Living Space Electrical: 110 VAC - Open or missing ground, A licensed electrician is recommended to evaluate and estimate repairs
Apex Inspection Services, LLC742 Evergreen Terrace Page 25 of 25