raid TRAINING KIT INSTRUCTIONS Evaluating Test Results The windows above represent all potential results. A weak positive, regardless of its intensity, should be considered positive. Invalids are rare but can occur when tests are outdated or open too long before testing. Invalid tests should be re-run. Write the time on the test or set your timer to allow 15 minutes to elapse before evaluating the tests. Evaluate your results as shown in panel 7 (right). 5 6 Timing The Test tox INSTRUCTION SHEET Alexeter Technologies LLC. 877-591-5571 www.alexeter.com RAPID ASSESSMENT INITIAL DETECTION 15:00 Set a timer to 15 minutes C T C T C T C T C T Strong Positive (Strong test line) Negative (No test line) Invalid (No control line) Invalid (No test lines) Weak Positive (Visible test line) 7 Dosing the test Drops are now easily dispensed by press- ing the sides of the collection tube. SLOWLY add the diluted sample into the oval sample well until you see all 5 test win- dows begin to flow red, as shown in panel 6 (right), then add 3 more drops. RAID TOX Instruction Sheet v3.indd 1 8/4/2011 2:14:21 PM

Weak Positive KIT (Visible test line) INSTRUCTION SHEET · 2019. 10. 15. · INSTRUCTIONS Evaluating Test Results The windows above represent all potential results. ... tox INSTRUCTION

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Weak Positive KIT (Visible test line) INSTRUCTION SHEET · 2019. 10. 15. · INSTRUCTIONS Evaluating Test Results The windows above represent all potential results. ... tox INSTRUCTION

fold

fold

fold

fold

raid

TRAININGKIT

INSTRUCTIONS

Evaluating Test Results

The windows above represent all potential results. A weak positive, regardless of its intensity, should be considered positive.

Invalids are rare but can occur when tests are outdated or open too long before testing. Invalid tests should be re-run.

Write the time on the test or set your timer to allow 15 minutes to elapse before evaluating the tests. Evaluate your results as shown in panel 7 (right).

5 6 Timing The Test

toxINSTRUCTION SHEET

AlexeterTechnologies LLC.

877-591-5571www.alexeter.com

R A P I D A S S E S S M E N T I N I T IA L D E T E C T I O N

15:00Set a timer to 15 minutes

C T

C T

C T

C T

C T

Strong Positive(Strong test line)

Negative(No test line)

Invalid(No control line)

Invalid(No test lines)

Weak Positive(Visible test line)

7Dosing the test

Drops are now easily dispensed by press-ing the sides of the collection tube.

SLOWLY add the diluted sample into the oval sample well until you see all 5 test win-dows begin to flow red, as shown in panel 6 (right), then add 3 more drops.

RAID TOX Instruction Sheet v3.indd 1 8/4/2011 2:14:21 PM

Page 2: Weak Positive KIT (Visible test line) INSTRUCTION SHEET · 2019. 10. 15. · INSTRUCTIONS Evaluating Test Results The windows above represent all potential results. ... tox INSTRUCTION

fold

fold

fold

fold

Alexeter Technologies LLC.Toll-free (24/7) 877-591-5571www.alexeter.com

RAID and its logos are registered trademarks of Alexeter Technologies 2011

After sampling and dosing either a RAID 5 or RAID 8 test, open the RAID TOX pouch and place the RAID TOX test on a flat sur-face. Locate the collection swab containing the original liquid sample and prepare to make a 1:50 dilution, as detailed in panel 2.

toxINSTRUCTION SHEET

Please review this entire sheet prior to using the test kit.

Do not open the pouch until you are ready to begin testing.

This RAID TOX kit has been designed to allow you to evaluate previously collected samples at a 1:50 dilution.

Intended to be used in conjnction with a RAID 5 or RAID 8 test, this precautionary dilution is evaluated on the RAID TOX test for “hook effect” issues that may result from oversampling.

The recommended operating temperature range for all RAID test kits is between 40° - 100° F. or 4° - 38° C

Recommended storage temperature for all RAID test kits is 40° - 86° F. or 4° - 30° C Collection

Swab Instruction sheet

RAID TOX

1 2 3

AlexeterTechnologies LLC.

RAID TOX Components

Insert the swab tightly back into the tube.

Using your thumb, (as shown) bend the buffer top until you hear it snap. Bend it again, in the other direction, until you hear another snap.

Sample Preparation 4

Squeeze Buffer Topand Shake

Remove Cap

Prepare 1:50 Dilution for RAID TOX test

To prepare a 1:50 dilution, remove the swab from the unused collection swab (included in this kit) and place one drop of your original liquid sample into the empty tube.

Sample Preparation

Return Swab

Snap Buffer Top

Squeeze the buffer top and shake to force buffer to the bottom of the tube. Shake the entire collection swab for several seconds to ensure proper mixing of sample and buffer.

Carefully remove the white cap from the collection swab. OVER

RAID TOX Instruction Sheet v3.indd 2 8/4/2011 2:14:50 PM