ABC123-05TITLE SHEET
CONSTRUCTION DOCUMENTSfor the construction of the
T-1VICINITY MAPFIELD SYMBOLOGY
COORDINATES LATITUDE: LONGITUDE:
SHEET NUMBER:
Phone No.: (818)898-2352 Fax No.: (818)898-918610640 Sepulveda Blvd. Suite 1, Mission Hills, CA 91345
PLANS PREPARED BY:
SHEET TITLE:
STAMP:
ABC123-05
HORST AVE.
SITE NAME:
REVISIONS:
C.E.S. PROJECT NO.:
76000363-52C.E.S. DWG. NO. ABC10029
SITE INFORMATION:
(PRELIMINARY ADDRESS)
ARTESIA, CA 90701(JPA POLE)
LA MIRADA
UTILITY COMPANY CONTACT INFO
PROJECT DESCRIPTION
SHEET INDEX
PROJECT SUMMARY
PROJECT TEAM
TBD TBD
SITE PLAN
A-1SHEET NUMBER:
Phone No.: (818)898-2352 Fax No.: (818)898-918610640 Sepulveda Blvd. Suite 1, Mission Hills, CA 91345
PLANS PREPARED BY:
SHEET TITLE:
STAMP:
ABC123-05
HORST AVE.
SITE NAME:
REVISIONS:
C.E.S. PROJECT NO.:
76000363-52C.E.S. DWG. NO. ABC10029
SITE INFORMATION:
(PRELIMINARY ADDRESS)
ARTESIA, CA 90701(JPA POLE)
LA MIRADA
25'
14'
2.25'
PROPOSED POWERPOINT OF CONNECTION
CONDUIT CURVE DATA
CITY OF ARTESIA PERMIT INFORMATION
HDD / OPEN TRENCH A/C ALLEY FOOTAGE: 138'
ITEM # DESCRIPTION
14'-6"
12'
19'
2'-6"
6'-6
"±
3'±1'-6"
4'-6
"±
26'
79'
4' 3.5'
135'
1'
CONTRACTOR TO PLACE
1.5'
ALL CONDUITS TO BE INSTALLEDBY HDD OR OPEN CUT PENDINGJURISDICTION SPECIFICATIONS
ALL CONDUITS TO BE INSTALLEDBY HDD OR OPEN CUT PENDINGJURISDICTION SPECIFICATIONS
CONTRACTOR TO REPLACE
HDD / OPEN TRENCH CONC. ALLEY FOOTAGE: 24'
HDD / OPEN TRENCH CONC. S.W. FOOTAGE: 0'
HDD / OPEN TRENCH GRASS/DIRT PARKWAY FOOTAGE: 61'
HDD / OPEN TRENCH TOTAL PROJECT FOOTAGE: 223'
24'
NOTE:CONTRACTOR TO ALLOW INGRESS ANDEGRESS TO DRIVEWAYS AT ALL TIMESDURING CONSTRUCTION.
CONTRACTOR TO REARRANGEDROPS TO ACCOMODATE SCESECONDARY RISER @ 4:00.
CONTRACTOR TO PLACE PULL BOX #1
45'
2.25'
PULL BOX LOCATION
1
ELEVATIONS 3
RISER DETAIL 2
ELEVATIONS
A-2SHEET NUMBER:
Phone No.: (818)898-2352 Fax No.: (818)898-918610640 Sepulveda Blvd. Suite 1, Mission Hills, CA 91345
PLANS PREPARED BY:
SHEET TITLE:
STAMP:
ABC123-05
HORST AVE.
SITE NAME:
REVISIONS:
C.E.S. PROJECT NO.:
76000363-52C.E.S. DWG. NO. ABC10029
SITE INFORMATION:
(PRELIMINARY ADDRESS)
ARTESIA, CA 90701(JPA POLE)
LA MIRADA
POLE MAKE READY INFORMATION
NOTE:
NOTE:COAX SHALL REMAIN STRAIGHT FOR AMINIMUM OF 4" FROM BOTTOM OFCONNECTOR TO BEGINNING OF THEBEND.
SITE LOCATION PHOTOS 1
SITE LOCATION PHOTOS
A-3SHEET NUMBER:
Phone No.: (818)898-2352 Fax No.: (818)898-918610640 Sepulveda Blvd. Suite 1, Mission Hills, CA 91345
PLANS PREPARED BY:
SHEET TITLE:
STAMP:
ABC123-05
HORST AVE.
SITE NAME:
REVISIONS:
C.E.S. PROJECT NO.:
76000363-52C.E.S. DWG. NO. ABC10029
SITE INFORMATION:
(PRELIMINARY ADDRESS)
ARTESIA, CA 90701(JPA POLE)
LA MIRADA
EQUIPMENT DETAILS
D-1SHEET NUMBER:
Phone No.: (818)898-2352 Fax No.: (818)898-918610640 Sepulveda Blvd. Suite 1, Mission Hills, CA 91345
PLANS PREPARED BY:
SHEET TITLE:
STAMP:
ABC123-05
HORST AVE.
SITE NAME:
REVISIONS:
C.E.S. PROJECT NO.:
76000363-52C.E.S. DWG. NO. ABC10029
SITE INFORMATION:
(PRELIMINARY ADDRESS)
ARTESIA, CA 90701(JPA POLE)
LA MIRADA
POLE MOUNTED EQUIPMENT 85ANDREW ION RADIO
FRONT VIEW
BACK VIEWANTENNA MOUNT DETAIL 7
1 VECTOR DETAIL (TOP ARRAY) ANTENNA 4ANTENNA 32 VECTOR DETAIL (LOWER ARRAY)
NOTE:COAX SHALL REMAIN STRAIGHTFOR A MINIMUM OF 4" FROMBOTTOM OF CONNECTOR TOBEGINNING OF THE BEND.
6BTI RADIO UNIT
RF INFORMATION
D-2SHEET NUMBER:
Phone No.: (818)898-2352 Fax No.: (818)898-918610640 Sepulveda Blvd. Suite 1, Mission Hills, CA 91345
PLANS PREPARED BY:
SHEET TITLE:
STAMP:
ABC123-05
HORST AVE.
SITE NAME:
REVISIONS:
C.E.S. PROJECT NO.:
76000363-52C.E.S. DWG. NO. ABC10029
SITE INFORMATION:
(PRELIMINARY ADDRESS)
ARTESIA, CA 90701(JPA POLE)
LA MIRADA
RF SYSTEM 3SCHEDULE
RF SYSTEM SCHEDULE
GPS SURVEY 1A
ANTENNA WIRE DIAGRAM 1
2 RF SIGNAGEDETAIL
CAUTION
Radio Frequency (RF) emissions are present at thislocation. Workers are asked to remain 3 feet from the face
of the antennas (MAD). Continued exposure to the RFenergy may exceed Federal limits set for General
Population/Uncontrolled environment. Utility workers whomust work within the MAD should first contact
CONTRACTOR 's NOC (7/24). NOC will dispatch aTechnician or provide assistance in de-energizing the
antennas.
CONTRACTOR NOC:888-393-2213SITE ID: ABC123-05
NOTE:
POWER PEDESTAL DETAILS
E-1SHEET NUMBER:
Phone No.: (818)898-2352 Fax No.: (818)898-918610640 Sepulveda Blvd. Suite 1, Mission Hills, CA 91345
PLANS PREPARED BY:
SHEET TITLE:
STAMP:
ABC123-05
HORST AVE.
SITE NAME:
REVISIONS:
C.E.S. PROJECT NO.:
76000363-52C.E.S. DWG. NO. ABC10029
SITE INFORMATION:
(PRELIMINARY ADDRESS)
ARTESIA, CA 90701(JPA POLE)
LA MIRADA
1 2
3 4 6
SINGLE METER SERVICE PEDESTAL
100 AMP MYERS ELECTRICAL METER PEDESTAL 100 AMP MYERS ELECTRICAL METER PEDESTAL(ISOMETRIC)
100 AMP MYERS ELECTRICAL METER PEDESTAL 100 AMP MYERS ELECTRICAL METER PEDESTAL(WIRE DIAGRAM)
5100 AMP MYERS ELECTRICAL METER PEDESTALCONCRETE PAD DETAIL
TYPICAL ANCHOR BOLT DETAIL
E-2SHEET NUMBER:
Phone No.: (818)898-2352 Fax No.: (818)898-918610640 Sepulveda Blvd. Suite 1, Mission Hills, CA 91345
PLANS PREPARED BY:
SHEET TITLE:
STAMP:
ABC123-05
HORST AVE.
SITE NAME:
REVISIONS:
C.E.S. PROJECT NO.:
76000363-15C.E.S. DWG. NO. ABC10029
SITE INFORMATION:
(PRELIMINARY ADDRESS)
ARTESIA, CA 90701(JPA POLE)
(LA MIRADA)
PANEL
ITEM # DESCRIPTION
PROPOSED POWERPOINT OF CONNECTION
CONTRACTOR TO REARRANGEDROPS TO ACCOMODATE SCESECONDARY RISER @ 4:00.
ALL CONDUITS TO BE INSTALLEDBY HDD OR OPEN CUT PENDINGJURISDICTION SPECIFICATIONS
CONTRACTOR TO PLACE
ALL CONDUITS TO BE INSTALLEDBY HDD OR OPEN CUT PENDINGJURISDICTION SPECIFICATIONS
CONTRACTOR TO REPLACE
SINGLE LINE &GENERAL NOTES
SITE PLANSINGLE LINE &
GENERAL NOTES
SITE PLAN
GROUNDING DETAILS
G-1SHEET NUMBER:
Phone No.: (818)898-2352 Fax No.: (818)898-918610640 Sepulveda Blvd. Suite 1, Mission Hills, CA 91345
PLANS PREPARED BY:
SHEET TITLE:
STAMP:
ABC123-05
HORST AVE.
SITE NAME:
REVISIONS:
C.E.S. PROJECT NO.:
76000363-52C.E.S. DWG. NO. ABC10029
SITE INFORMATION:
(PRELIMINARY ADDRESS)
ARTESIA, CA 90701(JPA POLE)
LA MIRADA
4 52-HOLE LB GROUNDING LUGCONNECTION OF COAX GROUND KIT TO ANTENNA COAX
3TYPICAL GROUND BAR
2TYPICAL WOOD POLE GROUNDING DETAIL GROUND TEST WELL DETAIL1
JURISDICTIONAL DETAILS
J-1SHEET NUMBER:
Phone No.: (818)898-2352 Fax No.: (818)898-918610640 Sepulveda Blvd. Suite 1, Mission Hills, CA 91345
PLANS PREPARED BY:
SHEET TITLE:
STAMP:
ABC123-05
HORST AVE.
SITE NAME:
REVISIONS:
C.E.S. PROJECT NO.:
76000363-52C.E.S. DWG. NO. ABC10029
SITE INFORMATION:
(PRELIMINARY ADDRESS)
ARTESIA, CA 90701(JPA POLE)
LA MIRADA
SCE DETAIL 2CITY OF ARTESIA DETAIL1
Earth Cover
Customer- Installed Conduit
For minimum cover seeTable 3-1 "Conduit orCable System MinimumCover," (page 3-12)
Sidewalk
Public Way or Easement
Gutter Grade
For minimum cover see Table 3-1 "Conduit or CableSystem Minimum Cover," (page 3-12). Cover may begreater due to prior subway structures.
Coupler or Adapter: Fittings to be conduit manufacturer's standardfitting for type of conduit used. If proper fitting are not obtainableCompany approved substitutes may be used.
Separation of 3 inches of concrete or 12 inches of earth between telephone and electric conduit is required. (Base spacers whenrequired, shall be placed at 10 foot maximum intervals.)
1" 3"
Bedding
1½"
30"(MIN)Typ.3"
Spacer
ConcreteEnvelope
1½"
30"(MIN)Typ.
3"
3"
3"