WaveRunner 6 Zi Oscilloscopes 400 MHz –4 GHz Key Features 400 MHz - 4 GHz bandwidths Up to 40 GS/s sample rate 12.1” touch screen display Advanced Tools Spectrum Analyzer Mode WaveScan – Search and Find LabNotebook Documentation and Report Generation History Mode - Waveform Playback Comprehensive set of serial data analysis, debug, validation and com- pliance tools Advanced Triggering with TriggerScan and Measurement Trigger WaveRunner 620MZi complete debug bundle available 18 digital channels with 2 GS/s Analog and Digital Cross-Pattern Triggering Digital Pattern Search and Find Analog and Digital Timing Measurements Logic Gate Emulation Activity Indicators Superior Validation, Debug, Analysis The WaveRunner 6 Zi defines superiority in a test instrument with a powerful feature set including a wide range of application packages, advanced triggering to isolate events, a user interface developed for quick and easy navigation, a wide range of probing options, and lightning-fast performance. Excellent Signal Fidelity The WaveRunner 6 Zi features a pristine signal path that offers unmatched signal fidelity with low noise, providing accuracy which can be counted on. This performance is augmented by a huge offset and timebase delay adjustment to allow easy signal and amplifier performance assessment and zooming on vertical and horizontal signal characteristics. Most Comprehensive Serial Data Analysis WaveRunner 6 Zi offers the most tools for serial data analysis. With over 30 trigger, decode, and compliance solutions, WaveRunner 6 Zi can address problems with unique, powerful views and automated tools. The SDAII serial data analysis package performs eye diagram and jitter testing which is ideal for characterization and debug. WaveRunner 620MZi The WaveRunner 620MZi model includes some of the most commonly used options as part of the standard configuration, reducing confusion when choosing a powerful toolset for debugging. In addition to the versatile software options, it is equipped with 40 GS/s and 128 Mpts of memory to ensure common debug needs are covered. The WaveRunner 6 Zi oscilloscope family features 400 MHz - 4 GHz of bandwidth, 40 GS/s sampling rate, exceptional signal fidelity, and fast operation, helping to get the job done quickly and accurately. The versatile toolset provides every necessity for an engineer to validate a design, debug errors at board bring up, and offer powerful analysis capabilities to characterize an embedded system. The WaveRunner 6 Zi is the ultimate debug machine. Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) ® E s t a blishe d 1 9 8 1

WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

WaveRunner 6 Zi Oscilloscopes400 MHz –4 GHz

Key Features

• 400 MHz - 4 GHz bandwidths

• Up to 40 GS/s sample rate

• 12.1” touch screen display

• Advanced Tools

– Spectrum Analyzer Mode

– WaveScan – Search and Find

– LabNotebook Documentationand Report Generation

– History Mode - WaveformPlayback

• Comprehensive set of serial dataanalysis, debug, validation and com-pliance tools

• Advanced Triggering withTriggerScan andMeasurement Trigger

• WaveRunner 620MZi completedebug bundle available

• 18 digital channels with 2 GS/s

– Analog and Digital Cross-PatternTriggering

– Digital Pattern Search and Find

– AnalogandDigitalTiming Measurements

– Logic Gate Emulation

– Activity Indicators

Superior Validation, Debug, AnalysisTheWaveRunner6Zidefines superiority in a test instrument with a powerful feature set including a wide range of application packages, advanced triggering to isolate events, a user interface developed for quick and easy navigation, a wide range of probing options, and lightning-fast performance.

Excellent Signal FidelityTheWaveRunner6Zifeaturesapristinesignal path that offers unmatched signalfidelitywithlownoise,providingaccuracy which can be counted on. Thisperformanceisaugmentedbya huge offset and timebase delay adjustment to allow easy signal and amplifierperformanceassessmentand zooming on vertical and horizontal signal characteristics.

Most Comprehensive Serial Data AnalysisWaveRunner6Zioffersthemost tools for serial data analysis. With over 30 trigger, decode, and compliance solutions,WaveRunner6Zicanaddress problems with unique, powerful viewsandautomatedtools.TheSDAIIserial data analysis package performs eye diagram and jitter testing which is ideal for characterization and debug.

WaveRunner 620MZiTheWaveRunner620MZimodelincludes some of the most commonly used options as part of the standard configuration,reducingconfusionwhen choosing a powerful toolset for debugging. In addition to the versatile software options, it is equipped with 40 GS/sand128Mptsofmemorytoensure common debug needs are covered.

The WaveRunner 6 Zi oscilloscope family features 400 MHz - 4 GHz of bandwidth, 40 GS/s sampling rate, exceptional signal fidelity, and fast operation, helping to get the job done quickly and accurately. The versatile toolset provides every necessity for an engineer to validate a design, debug errors at board bring up, and offer powerful analysis capabilities to characterize an embedded system. The WaveRunner 6 Zi is the ultimate debug machine.

Advanced Test Equipment Rentalswww.atecorp.com 800-404-ATEC (2832)

®

Established 1981

Page 2: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

2

WaveRunner 6 Zi combines the power of a fully featured multi-purpose oscilloscope, a dedicated logic analyzer for mixed signal design, and a protocol analyzer for serial data debug.

1. Industry leading performance— 400MHz—4GHz,40GS/s, 128Mptsof analysismemory

2. 12.1"Widescreen(16x9)highresolutionWXGAcolortouchscreen display

3. 90ºrotatingandtiltingdisplayforoptimal viewing of signals

4. Smallfootprint,only8.1"deep

5. Easy connectivity with two convenient USBportsonthefront, two ontheside

6. USBTMC(TestandMeasurementClass)portsimplifiesprogramming

7. Deepesttoolboxwithmoremeasurement, more math, more power

COMPLETE DEBUG SOLUTION FROM 400 MHz–4 GHz

13

Accessory pouch option available.

6

5

3

1

7

8

Page 3: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

3

8. Largest selection of serial triggers and decoders—morethan20—availabletoprovide a total system view

9. Serial trigger captures signals up to3Gb/s

10. WavePilot consolidates important oscilloscope debug features in one place. LEDs illuminate to indicate navigation options and active oscilloscope features

11. TheSuperKnobprovidesjoystickcontrolto easily navigation to key debug and documentation features

12. LBUSprovideseasyconnectiontotheoptionalmixedsignalfeature,providingupto36digitalchannels

13. Wide array of probes and accessories to accommodate any probing challenge

COMPLETE DEBUG SOLUTION FROM 400 MHz–4 GHz

10

5

2

4

3

11

9

12

Page 4: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

4

Advanced Trigger CapabilitiesA powerful combination of high band-widthedgeand10differentSMARTtriggers, four stage cascade triggering, measurement trigger, and triggerscan areallstandard.Thesefeaturesallowyou to isolate the problem quickly andbeginfocusingonthecause.Themeasurement trigger offers a powerful option to qualify a trigger event based onaqualifiedmeasurementwithgreatresolution. A high-speed serial trigger enablestriggeringonupto3Gb/sserialpatternsofupto80-bitsinlength. Afullrangeofserialtriggers(I2C,SPI,UART,RS-232,Audio(I2S,LJ,RJ,TDM),CAN,LIN,FlexRay,MIL-STD-1553,SATA,8b/10b,USBandmanyothers)are also available.

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

A B

I2C

FlexRay

SPI LIN UART UART

DEEP INSIGHT TO CLARIFY COMPLEX SIGNALS

Sequence Mode AcquisitionSequence mode enables capture offinedetailsofcomplexeventsequences occurring over long time intervals, while ignoring the intervals between events, allowing for the most efficientuseoftheoscilloscope’smemory.Timestampsareprovidedfor each acquisition and dead-time between triggers is minimized to less than1μs.CombineSequencemodewith advanced triggers to isolate rare events over time and analyze afterwards.

TriggerScan™

TriggerScanuseshigh-speedhardwaretriggering capability with persistence displays to capture only the signals of interest and provide answers up to 100timesfasterthanothermethods.Traditionalfastdisplayupdatemodeswork best on frequent events occurring onslowedgerateswhileTriggerScanexcelsinfindinginfrequenteventsonfast edge rates.

WaveScan Advanced SearchWaveScan provides powerful isola-tion capabilities that hardware triggers can’tprovideinordertolocaterunts,glitches, and other waveform anoma-lies. WaveScan allows searching analog, digital or parallel bus signals in a single acquisition using more than 20differentcriteria.Or,setupascancondition and scan for an event over hours or even days.

History ModeHistory mode lets you scroll back in time to isolate those anomalies, measure them with parameters or cursors,andquicklyfindthesourceof theproblem.Historymodeisalwaysbufferingwaveforms,sono useractionis required to save traces, only to invoke the viewer.

Page 5: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

5

DEEP INSIGHT TO CLARIFY COMPLEX SIGNALS DISPLAY OPTIMIZED FOR ANALYSIS

Graphical Track, Trend, and Histogram ViewsThetrackmathfunctionplotsmeasurementvaluesontheY-axisandtimeontheX-axistodisplayameasurement change time-correlated to the original channel acquisition; perfect for intuitive understanding of behaviors in frequency modu-lated(FM)orpulsewidthmodulated(PWM)circuitsandjittermeasure-ments, including modulation or spikes. Histograms provide a visual distribu-tion representation of a large sample of measurements, allowing faster insight.Thetrendmathfunctionisideal forplottingslowchangesinmeasurement values.

Rotating DisplayThe12.1"highresolutionWXGAwide screenisdesignedtoprovidethe bestviewofanysignaltypeon the display.

Thewidescreenisidealforavarietyofsignals where long records are required and zooming or scrolling results in a large block of data.

Rotatethescreen90°degreesto optimize the display for viewing digital signals, jitter tracks, eye diagrams, and frequencyplots.Thescreenimagewilladjust automatically when rotated.

Tiltthedisplayupordownineitherorientation to minimize reflections or glare.

Page 6: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

6

The WaveRunner 6 Zi features the most complete serial data solutions. Solving serial data problems requires intimate knowledge of the protocol to get started. With the WaveRunner 6 Zi, the oscilloscope is the expert. Simply connect your probes or cables and the scope can provide the correct level of detail needed to view, debug, and analyze the serial data signals.

Solutions address the Embedded, Military and Avionics, Handset/Mobile/Cellular, and Storage/Peripherals/Interconnects, with a combination of decode, trigger, measure/graph, ProtoSync, and compliance tools.

Whether the protocol under test is a new emerging standard requiring jitter and eye diagram testing, a mature standard requiring compliance testing, or an embedded standard requiring protocol measurement and timing analysis, WaveRunner 6 Zi has it all.

A TOTAL SOLUTION FOR SERIAL DATA

ViewDecodeViewing the protocol layer has never been easier with the intuitive color overlay. Advanced software algorithms understand the selected protocol and deconstruct the waveform into protocol information, then overlay the decodeddataonthe waveform.

TableThetablefeatureturnsyour oscilloscope into a protocol analyzer. Customconfigurethetabletodisplayonly the information you want, and exporttabledatatoanexcelfile.Toucha message in the table and automati-callyzoomfordetail.Thisfeatureisstandard with decode options.

SearchSerial data messages can be quickly located by searching on Address, Data,andotherattributesspecifictoa particularprotocol.Thisfeatureisstandard with decode options.

DebugMeasureTimingandbusmeasurementsallow quickandeasycharacteriza-tionofaserialdatasystem.ThePROTObusMAGtoolkitisthebasicbuilding block upon which many other serial triggeranddecoderoptionscan beadded.

GraphExtractdatafromtheserialprotocolmessage stream and use the track functions to graphically plot that data onthedisplay.Thedigitaldataisused to create an analog waveform that can then be compared to other electrical signals.

Learn More http://lcry.us/oHoltC

True Hardware Protocol TriggerAn80-bitserialtriggerforserialdata signalsupto3Gb/s(includingSATA,8b/10bandUSB)and  aconditionaltrigger(I2C,SPI, UART,CAN,LIN,FlexRay,™I2S, Mil-STD-1553)cancompletelyisolatespecificmessageevents.

Page 7: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

7

AnalyzeEye DiagramsCreateeyediagramsutilizingthefull memoryformaximumstatisticalsignificance.UniqueeyediagramfeaturessuchasIsoBERandeye violation locator provide powerful insight into physical layer analysis.

JitterTheintegratedclockandjitteranalysistools use advanced jitter decomposi-tion methodologies and tools to provide moreinformationaboutrootcause.TJanalysis,RjBUjanalysisandDDjanal-ysis are made simple with the deepest

toolsetdedicatedtoproviding thehighest level of insight into your serial data signals.

Learn More http://lcry.us/n1OmTV

ComplianceAutomated compliance and testing issimplifiedwiththeQPHYsoftwareoption.QPHYfeatures automatedscripts, connection diagrams, and testreports togreatlysimplifythe compliance process.

Learn More teledynelecroy.com/serialdata

ProtoSyncProtoSync combines the oscilloscope view with a simul-taneousview ofdatalinklayerdecodes on the same instrument. ThiscombinationmakesProtoSyncvery effective in debugging PCIExpressnegotiationrates.

CompatiblewithPCIExpress,USB2,SAS,SATA,andFibreChannel.

WaveRunner6Zi Serial Data Protocol Support

Deco

deTr

igge

rM

easu

re/G

raph

Prot

oSyn

cQ

uailP

HY

I2C • • •

SPI • • •

I2S • • •UART, RS-232

• • •

CAN • • •

CAN FD • •

LIN • • •

SENT • •

FlexRay • • •

MOST50/150 •

ARINC 429 • •

MIL-STD-1553 • • •

DigRF 3G • •MIPI D-PHY /CSI-2/DSI

• •

MIPI M-PHY • •

DigRF v4 • •

8b/10b • •

BroadR-Reach •

Fibre Channel • •

SATA (1.5 & 3 Gb/s) • • • •

SAS (1.5 & 3 Gb/s) • •

PCI Express (Gen1) • • •

USB 2.0 • • • •

USB2-HSIC •

LPDDR2 •

DDR2 •

DDR3 •

Ethernet • •

Manchester •

NRZ •

Embe

dded

Auto

mot

ive

Mili

tary

&

Avio

nics

Han

dset

Ce

llula

r M

obile

Stor

age

/ Per

iphe

rals

In

terc

onne

cts

Seria

l Dat

a

Com

posi

tion

Page 8: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

8

SDA II – Advanced Tools to Isolate and Analyze (WR6Zi-SDAII)Unleashthepowerofserial dataanalysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or hostfailscompliance.TheSDAIIarchi-tecture provides fast updates and eye diagramcreation.Combinedwithupto128Mptsrecordlengthsandmorecomplete jitter decomposition tools, SDA II provides a fast and complete understanding of why serial data fails a compliance test. Whether debugging eye pattern or other compliance test failures,theWaveRunner6ZiSeriesrapidly isolates the source of the problem.

APPLICATION SPECIFIC SOLUTIONS

Advanced jitter decomposition meth-odologies and tools provide more informationaboutrootcause.TjAnalysis,RjBUjAnalysisandDDj

Analysis are made simple with the deepest toolset dedicated to providing the highest level of insight into your serial data signals.

Compliance Reports contain all of the tested values, the specific test limits and screen captures. Compliance Reports can be created as HTML, PDF or XML.

QualiPHYQualiPHYisdesignedtoreducethetime,effort,andspecializedknowledge needed to perform compliance testing on high-speed serial buses.

• Guides the user through each test setup

• Performs each measurement in accordance with the relevant test procedure

• Compareseachmeasuredvaluewiththeapplicable specification limits

• Fully documents all results

• QualiPHYhelpstheuserperformtestingtherightway— every time

Supported Standards:– ENET

– USB

– DDR2,DDR3,LPDDR2

– MIPI-DPHY

– BroadR-Reach

– MOST50,MOST150

Page 9: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

9

Eye Doctor II (WR6Zi-EYEDRII)TheEyeDoctorIIadvancedsignalintegrity toolkit enables a complete set of channel emulation, de-embedding, and receiver equalization simulation tools. It provides capability to emulate a serial data link, de-embed or embed afixture,cableorserialdatachannel,add or remove emphasis, and perform CTLE,FFE,orDFEequalization.

Power Analyzer Software Option (WR6ZI-PWR)Quicklymeasureandanalyzeoperatingcharacteristics of power conversion circuits. Make automatic switching device measurements and identify areas of loss and conduction with color-codedoverlay.Controlloopmodulation analysis and line power harmonictestingareallsimplifiedwitha dedicated user interface.

Advanced Probe InterfaceThe advanced active probe interface gives tremendous flexibility for measuring high voltages, high frequencies, currents, or differential signals.

High Impedance Active Probes

High Bandwidth Differential Probes

High Voltage Differential Probes

High Voltage Passive Probes

Current Probes

DDR Debug Toolkit (WR6Zi-DDR3-Toolkit)TheDDRDebugToolkitprovidestest, debug and analysis tools for the entireDDRdesigncycle.TheuniqueDDR analysis capabilities provide automatic Read and Write burst sepa-ration, bursted data jitter analysis and DDR-specificmeasurementparam-eters.TheWaveRunner6Zisupportsboth standard and custom speed gradesofDDR2andDDR3.

Jitter and Timing Analysis Option (WR6Zi-JITKIT)JITKITmakesitsimpleandeasytounderstand the basic system jitter performance of clock signals and clock-data activities, including period, half period, cycle-cycle, skew, amplitude, differential voltage crossing, slew rate, and a wide variety of other common jitter measurements.

After

Before

Page 10: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

10

WAVERUNNER 620MZI

Spectrum Analyzer Option (WR6Zi-SPECTRUM)TheSpectrumAnalyzermodeprovidesa spectrum analyzer style user inter-facewithcontrolsforstart/stopfrequency or center frequency and span.Theresolutionbandwidthisauto-matically set for best analysis or can be manually selected. Vertical Scale can be selected in the desired units and the unique peak search automati-cally labels spectral components and presents frequency and level in an interactivetable.Tomonitorhowthespectrum changes over time, view the spectrogramwhichcandisplaya2Dor3D history of the frequency content.

Having the most commonly used debug tools as part of the standard configuration, the WaveRunner 620MZi model

provides a powerful set of analysis tools for effective debugging. By combining 40 GS/s sample rate and 128 Mpts of

memory with a powerful set of triggers, signals of interest can be isolated with ease. The inclusion of the Spectrum

Analyzer and Serial Trigger and Decode options creates a powerful multi-instrument tool for looking at a system under

test from multiple perspectives. The XDEV customization option and digital filtering package allow the debug setup to

emulate custom applications.

What’s included with the WaveRunner 620MZi?

• 128 Mpts of Memory

• 40 GS/s Sample Rate

• Spectrum Analyzer Software

• Digital Filter Software

• XDEV Customization Package

• I2C Trigger and Decode

• SPI Trigger and Decode

• UART Trigger and Decode

Page 11: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

11

40 GS/s Sample Rate and 128 Mpts of Long MemoryA40GS/ssamplerateallowsforadetailed edge reconstruction even for signalswiththefastestrisetimes.Thisis critical for detecting signal integrity issues such as reflections.

Deepmemoryof128Mptsisidealfordebugging long term behavior on high speedserialdatabuses.Forexample,slowly varying physical-layer charac-teristics such as Spread Spectrum Clocking(SSC)mustbeanalyzedoverperiods of milliseconds.

I2C, SPI, and UART Trigger and Decode (WR6Zi-EMB)A serial data trigger will quickly isolate events on a bus eliminating the need to set manual triggers and hoping to catchtherightinformation.Triggerconditions can be entered in binary or hexadecimalformatsandconditionaltrigger capabilities even allow triggering on a range of different events.

Protocol decoding is shown directly on the waveform with an intuitive, color-coded overlay and presented in binary,hexorASCII.Decodingisfasteven with long memory, and zooming in to the waveform shows precise byte by byte decoding.

Digital Filter Software Option (WR6Zi-DFP2)DFP2letsyouimplementFiniteImpulseResponse(FIR)orInfiniteImpulseResponse(IIR)filterstoelimi-nate undesired spectral components, such as noise, and enhances your abilitytoexamineimportantsignalcomponents. You can choose from astandardsetofFIRorIIRfiltersoryou can also design your own custom filters.CreateandapplyavarietyofFIRandIIRdigitalfilterstoyourcapturewaveforms or processed traces.

XDEV Customization Option (WR6Zi-XDEV)With the XDEV option, third party programs can be completely integrated intotheoscilloscope’sprocessingstream.Createcustomizedmathfunc-tionsandparametersusingC/C++,MATLAB,Excel,JScriptorVisual Basicwithouteverleavingthe oscilloscope application - and view the results directly on the oscilloscope, in real-time.

Page 12: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

12

WaveRunner 604Zi

WaveRunner 606Zi

WaveRunner 610Zi

Vertical SystemAnalogBandwidth@50Ω(-3dB) 400 MHz

(≥2mV/div)600MHz

(≥2mV/div)1GHz

(≥2mV/div)AnalogBandwidth@1MΩ (-3dB) 400 MHz

(typical)500MHz (typical)

500MHz (typical)

RiseTime(10–90%,50Ω) 875ps (typical)

580ps (typical)

375ps (typical)

RiseTime(20–80%,50Ω) 650ps (typical)

435ps (typical)

280ps (typical)

InputChannels 4BandwidthLimiters 20MHz,

200MHz20MHz, 200MHz

20MHz, 200MHz

Input Impedance 50Ω±2%or1MΩ||17pF,10MΩ||9.5pFwithsuppliedProbeInputCoupling 1MΩ:AC,DC,GND;50Ω:DC,GNDMaximumInputVoltage 50Ω:5Vrms±10Vpeak

1MΩ:400Vmax.(DC+peakAC<10kHz)Channel-ChannelIsolation >100:1uptoratedBW

Vertical Resolution 8-bits;upto11-bitswithenhancedresolution(ERES)Sensitivity 50Ω:1mV/div–1V/div,fullyvariable

1MΩ:1mV/div–10V/div,fullyvariableDCVerticalGainAccuracy (GainComponentofDCAccuracy)

±1%F.S.(typical),offsetat0V

OffsetRange 50 Ω: ±1.6V@1mV–4.95mV/div ±4V@5mV–9.9mV/div ±8V@10mV–19.8mV/div ±10V@20mV–1V/div1 MΩ: ±1.6V@1mV–4.95mV/div ±4V@5mV–9.9mV/div ±8V@10mV–19.8mV/div ±16V@20mV–140mV/div ±80V@142mV–1.4V/div ±[email protected]–10V/div

DCVerticalOffsetAccuracy ±(1.5%ofoffsetsetting+1%offullscale+1mV) (testlimit)

Horizontal SystemTimebases Internaltimebasecommonto4inputchannels;anexternalclockmaybeappliedattheauxiliaryinputTime/DivisionRange 20ps/div-1.6ks/divwithstandardmemory

(upto3.2ks/divwith-Smemory,6.4ks/divwith-Mmemory) RISavailableat≤10ns/div; RollModeavailableat≥100ms/divand≤5MS/s

ClockAccuracy ≤1.5ppm+(agingof0.5ppm/yrfromlastcalibration)TriggerandInterpolatorJitter ≤4.5psrms

(typical)<0.1psrms

(typical,softwareassisted)

≤4psrms (typical)<0.1psrms

(typical,softwareassisted)

≤3.5psrms (typical)<0.1psrms

(typical,softwareassisted)Channel-ChannelDeskewRange ±9xtime/div.setting,100msmax.,eachchannelExternalTimebaseReference(Input) 10MHz±25ppmviaoptionalLBUSBNCadapterExternalTimebaseReference(Output) 10MHz3.5dBm±1dBm,synchronizedtoreferencebeingusedbyuser(internalorexternalreference)

viaoptionalLBUSBNCadaptorExternalClock DCto100MHz;(50Ω/1MΩ),Ext.BNCinput,

Minimum rise time and amplitude requirements apply at low frequencies

SPECIFICATIONS

Page 13: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

13

WaveRunner 620Zi

WaveRunner 620MZi

WaveRunner 625Zi

WaveRunner 640Zi

Vertical SystemAnalogBandwidth@50Ω(-3dB) 2GHz

(≥5mV/div)2.5GHz

(≥5mV/div)4 GHz

(≥5mV/div)AnalogBandwidth@1MΩ(-3dB) 500MHz

(typical)500MHz (typical)

500MHz (typical)

RiseTime(10–90%,50Ω) 175ps (typical)

160ps (typical)

100ps (typical)

RiseTime(20–80%,50Ω) 130ps (typical)

120ps (typical)

75ps (typical)

InputChannels 4BandwidthLimiters 20MHz,

200MHz,1GHz20MHz,

200MHz,1GHz20MHz,

200MHz,1GHzInput Impedance 50Ω±2%or1MΩ||17pF,10MΩ||9.5pFwithsuppliedProbeInputCoupling 1MΩ:AC,DC,GND;50Ω:DC,GNDMaximumInputVoltage 50Ω:5Vrms±10Vpeak

1MΩ:400Vmax.(DC+peakAC<10kHz)Channel-ChannelIsolation

>100:1uptoratedBW>100:1upto2.5GHz>30:1from2.5GHzto

ratedBWVertical Resolution 8-bits;upto11-bitswithenhancedresolution(ERES)Sensitivity 50Ω:1mV/div–1V/div,fullyvariable

1MΩ:1mV/div–10V/div,fullyvariableDCVerticalGainAccuracy (GainComponentofDCAccuracy)

±1%F.S.(typical),offsetat0V

OffsetRange 50 Ω: ±1.6V@1mV–4.95mV/div ±4V@5mV–9.9mV/div

±8V@10mV–19.8mV/div ±10V@20mV–1V/div

1 MΩ: ±1.6V@1mV–4.95mV/div ±4V@5mV–9.9mV/div

±8V@10mV–19.8mV/div ±16V@20mV–140mV/div ±80V@142mV–1.4V/div ±[email protected]–10V/div

50 Ω: BWL ≤ 1 GHz

±1.6V@1mV–4.95mV/div ±4V@5mV–9.9mV/div

±8V@10mV–19.8mV/div ±10V@20mV–1V/div

BWL > 1 GHz ±1.4V@5mV–122mV/div ±10V@124mV–1V/div

1 MΩ: ±1.6V@1mV–4.95mV/div ±4V@5mV–9.9mV/div

±8V@10mV–19.8mV/div ±16V@20mV–140mV/div ±80V@142mV–1.4V/div ±[email protected]–10V/div

DCVerticalOffsetAccuracy ±(1.5%ofoffsetsetting+1%offullscale+1mV)(testlimit)

Horizontal SystemTimebases Internaltimebasecommonto4inputchannels;anexternalclockmaybeappliedattheauxiliaryinputTime/DivisionRange 20ps/div-1.6ks/divwith

standard memory (upto3.2ks/divwith

-Smemory,6.4ks/divwith-Mmemory)

RISavailableat≤10ns/div; Roll Mode available at

≥100ms/divand≤5MS/s

20ps/div-6.4ks/divwithstandard memory

RISavailableat≤10ns/div;Roll Mode available at

≥100ms/divand≤5MS/s

20ps/div-1.6ks/divwithstandardmemory (upto3.2ks/divwith-Smemory,

6.4ks/divwith-Mmemory) RISavailableat≤10ns/div;

RollModeavailableat≥100ms/divand≤5MS/s

ClockAccuracy ≤1.5ppm+(agingof0.5ppm/yrfromlastcalibration)TriggerandInterpolatorJitter ≤3psrms

(typical)<0.1psrms

(typical,softwareassisted)

≤2.5psrms (typical)<0.1psrms

(typical,softwareassisted)

≤2psrms (typical)<0.1psrms

(typical,softwareassisted)Channel-ChannelDeskewRange ±9xtime/div.setting,100msmax.,eachchannelExternalTimebaseReference(Input) 10MHz±25ppmviaoptionalLBUSBNCadapterExternalTimebaseReference(Output) 10MHz3.5dBm±1dBm,synchronizedtoreferencebeingusedbyuser(internalorexternalreference)

viaoptionalLBUSBNCadaptorExternalClock DCto100MHz;(50Ω/1MΩ),Ext.BNCinput,

Minimum rise time and amplitude requirements apply at low frequencies

SPECIFICATIONS

Page 14: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

14

SPECIFICATIONS

WaveRunner 604Zi

WaveRunner 606Zi

WaveRunner 610Zi

Acquisition SystemSingle-ShotSampleRate/Ch 10GS/son4Ch

20GS/son2ChRandomInterleavedSampling(RIS) 200GS/sforrepetitivesignals

(20ps/divto10ns/div)MaximumTriggerRate 1,000,000waveforms/second(inSequenceMode,

upto4channels)IntersegmentTime 1µsStandardMemory(4Ch/2Ch/1Ch)(NumberofSegments)

16M/32M/32M(5,000)

MemoryOptions(4Ch/2Ch/1Ch)(NumberofSegments)

S-32Option: 32M/64M/64M(15,000)M-64Option: 64M/128M/128M(15,000)

Acquisition ProcessingAveraging Summedaveragingto1millionsweeps;continuousaveragingto1millionsweepsEnhancedResolution(ERES) From8.5-to11-bitsverticalresolutionEnvelope(Extrema) Envelope,floor,orroofforupto1millionsweepsInterpolation LinearorSinx/x

Triggering SystemModes Normal, Auto, Single, and StopSources Anyinputchannel,Ext,Ext/10,orline;slopeandleveluniquetoeachsource(exceptlinetrigger)CouplingMode DC,AC,HFRej,LFRejPre-trigger Delay 0-100%ofmemorysize(adjustablein1%incrementsor100ns)Post-trigger Delay 0-10,000divisionsinrealtimemode,limitedatslowertime/divsettingsorinrollmodeHold-offbyTimeorEvents From2nsupto20sorfrom1to99,999,999eventsInternalTriggerRange ±4.1divfromcenter(typical)TriggerSensitivitywithEdgeTrigger(Ch1–4)

2div@<400MHz1.5div@<200MHz0.9div@<10MHz

(DC,AC,and LFRejcoupling)

2div@<600MHz1.5div@<300MHz1div@<200MHz0.9div@<10MHz

(DC,AC,and LFRejcoupling)

2div@<1GHz1.5div@<500MHz1div@<200MHz 0.9div@<10MHz

(DC,AC,and LFRejcoupling)

ExternalTriggerSensitivity, (EdgeTrigger)

[email protected]@<500MHz1div@<200MHz0.9div@<10MHz(DC,AC,andLFRejcoupling)

Max.TriggerFrequency, SMARTTrigger

400MHz@≥ 10mV/div1.9ns

(minimumtriggerable width1.9ns)

600MHz@≥ 10mV/div1.2ns

(minimumtriggerable width1.2ns)

1.0GHz@≥ 10mV/div

(minimumtriggerable width750ps)

ExternalTriggerInputRange Ext(±0.4V);Ext/10(±4V)

Basic TriggersEdge Triggerswhensignalmeetsslope(positive,negative,oreither)andlevelconditionWindow TriggerswhensignalexitsawindowdefinedbyadjustablethresholdsTV-CompositeVideo TriggersNTSCorPALwithselectablelineandfield;

HDTV(720p,1080i,1080p)withselectableframerate(50or60Hz)andLine;or CUSTOMwithselectableFields(1–8),Lines(upto2000),FrameRates(25,30,50,or60Hz), Interlacing(1:1,2:1,4:1,8:1),orSynchPulseSlope(PositiveorNegative)

Page 15: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

15

SPECIFICATIONS

WaveRunner 620Zi

WaveRunner 620MZi

WaveRunner 625Zi

WaveRunner 640Zi

Acquisition SystemSingle-ShotSampleRate/Ch 10GS/son4Ch

20GS/son2Ch20GS/son4Ch40GS/son2Ch

RandomInterleavedSampling(RIS) 200GS/sforrepetitivesignals(20ps/divto10ns/div)

MaximumTriggerRate 1,000,000waveforms/second(inSequenceMode,upto4channels)

IntersegmentTime 1µsStandardMemory(4Ch/2Ch/1Ch)(NumberofSegments)

16M/32M/32M(5,000)

64M/128M/128M(15,000)

16M/32M/32M(5,000)

MemoryOptions(4Ch/2Ch/1Ch)(NumberofSegments)

S-32Option: 32M/64M/64M

(15,000)M-64Option:

64M/128M/128M(15,000)

NA

S-32Option: 32M/64M/64M

(15,000)M-64Option:

64M/128M/128M(15,000)

Acquisition ProcessingAveraging Summedaveragingto1millionsweeps;continuousaveragingto1millionsweepsEnhancedResolution(ERES) From8.5-to11-bitsverticalresolutionEnvelope(Extrema) Envelope,floor,orroofforupto1millionsweepsInterpolation LinearorSinx/xorcubic(usingmathtool)

Triggering SystemModes Normal, Auto, Single, and StopSources Anyinputchannel,Ext,Ext/10,orline;slopeandleveluniquetoeachsource(exceptlinetrigger)CouplingMode DC,AC,HFRej,LFRejPre-trigger Delay 0-100%ofmemorysize(adjustablein1%incrementsor100ns)Post-trigger Delay 0-10,000divisionsinrealtimemode,limitedatslowertime/divsettingsorinrollmodeHold-offbyTimeorEvents From2nsupto20sorfrom1to99,999,999eventsInternalTriggerRange ±4.1divfromcenter(typical)TriggerSensitivitywithEdgeTrigger(Ch1–4)ProBusInputs

2div@<2GHz1.5div@<1GHz1div@<200MHz 0.9div@<10MHz

(DC,AC,and LFRejcoupling)

2div@<2.5GHz1.5div@<1.25GHz1div@<200MHz 0.9div@<10MHz

(DC,AC,and LFRejcoupling)

2div@<4GHz1.5div@<2GHz1div@<200MHz 0.9div@<10MHz

(DC,AC,and LFRejcoupling)

ExternalTriggerSensitivity, (EdgeTrigger)

[email protected]@<500MHz1div@<200MHz0.9div@<10MHz(DC,AC,andLFRejcoupling)

Max.TriggerFrequency, SMARTTrigger

2.0GHz@≥ 10mV/div

(minimumtriggerable width400ps)

2.0GHz@≥ 10mV/div

(minimumtriggerable width300ps)

2.0GHz@≥ 10mV/div

(minimumtriggerable width200ps)

ExternalTriggerInputRange Ext(±0.4V);Ext/10(±4V)

Basic TriggersEdge Triggerswhensignalmeetsslope(positive,negative,oreither)andlevelconditionWindow TriggerswhensignalexitsawindowdefinedbyadjustablethresholdsTV-CompositeVideo TriggersNTSCorPALwithselectablelineandfield;

HDTV(720p,1080i,1080p)withselectableframerate(50or60Hz)andLine;or CUSTOMwithselectableFields(1–8),Lines(upto2000),FrameRates(25,30,50,or60Hz), Interlacing(1:1,2:1,4:1,8:1),orSynchPulseSlope(PositiveorNegative)

Page 16: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

16

WaveRunner 604Zi 606Zi

WaveRunner 610Zi 620Zi

620 MZi

WaveRunner 625Zi 640Zi

SMART TriggersStateorEdgeQualified Triggersonanyinputsourceonlyifadefinedstateoredgeoccurredonanotherinputsource.

Delay between sources is selectable by time or eventsQualifiedFirst InSequenceacquisitionmode,triggersrepeatablyoneventBonlyifadefinedpattern,state,oredge(eventA)is

satisfiedinthefirstsegmentoftheacquisition.HoldoffbetweensourcesisselectablebytimeoreventsDropout Triggersifsignaldropsoutforlongerthanselectedtimebetween1nsand20sPattern Logiccombination(AND,NAND,OR,NOR)of5inputs(4channelsandexternaltriggerinput.Eachsource

canbehigh,low,ordon’tcare.TheHighandLowlevelcanbeselectedindependently.Triggersatstartorendofthepattern

SMART Triggers with Exclusion TechnologyGlitch Triggersonpositiveornegativeglitcheswithwidthsselectableaslowas200ps(dependingonoscilloscopeband-

width)to20s,oronintermittentfaultsWidth(SignalorPattern) Triggersonpositiveornegativeglitcheswithwidthsselectableaslowas200ps(dependingonoscilloscopeband-

width)to20s,oronintermittentfaults

Interval(SignalorPattern) Triggersonintervalsselectablebetween1nsand20sTimeout(State/EdgeQualified) Triggersonanysourceifagivenstate(ortransitionedge)hasoccurredonanothersource.

Delaybetweensourcesis1nsto20s,or1to99,999,999eventsRunt Triggeronpositiveornegativeruntsdefinedbytwovoltagelimitsandtwotimelimits.

Selectbetween1nsand20nsSlew Rate Triggeronedgerates.SelectlimitsfordV,dt,andslope.Selectedgelimitsbetween1nsand20nsExclusionTriggering Triggeronintermittentfaultsbyspecifyingtheexpectedbehaviorandtriggeringwhenthatconditionisnotmet

Measurement TriggerTriggeronmeasurementvalues,Edge,SerialPattern,BusPattern,Non-monotonic

Cascade (Sequence) TriggeringCapability Armon“A”event,thenTriggeron“B”event.OrArmon“A”event,thenQualifyon“B”event,andTriggeron“C”event.

OrArmon“A”event,thenQualifyon“B”then“C”event,andTriggeron“D”eventTypes CascadeAthenB:Edge,Window,Pattern(Logic)Width,Glitch,Interval,Dropout,orMeasurement.Measurement

canbeonStageBonly.CascadeAthenBthenC(Measurement):Edge,Window,Pattern(Logic),Width,Glitch,Interval,Dropout,or Measurement.MeasurementcanbeonStageConly.CascadeAthenBthenC:Edge,Window,Pattern(Logic).CascadeAthenBthenCthenD:Edge,Window,Pattern(Logic),orMeasurement.MeasurementcanbeonStageDonly

Holdoff HoldoffbetweenAandB,BandC,CandDisselectablebytime(1nsto20s)ornumberofevents.MeasurementtriggerselectionasthelaststageinaCascadeprecludesaholdoffsettingbetweentheprior stage and the last stage.

Optional High-speed Serial Protocol Triggering (WR6Zi-80B-8B10B TD)Data Rates 150Mb/s–3Gb/sPattern Length 80-bits,NRZor8b/10bClockRecoveryJitter 1psrms+0.3%UnitIntervalRMSforPRBSdatapatternswith

50%transitiondensityHardwareClockRecoveryLoopBW PLLLoopBW=Fbaud/5500,100Mb/s

to2.488Gb/s(typical)

Color Waveform DisplayType Color12.1"widescreenflatpanelTFT-ActiveMatrixwithhighresolutiontouchscreenResolution WXGA;1280x800pixelsNumberofTraces Displayamaximumof16traces.Simultaneouslydisplaychannel,zoom,memoryandmathtracesGrid Styles Auto,Single,Dual,Quad,Octal,X-Y,Single+X-Y,Dual+X-YWaveform Representation Sample dots joined, or sample dots only

SPECIFICATIONS

Page 17: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

17

SPECIFICATIONS

WaveRunner 604Zi 606Zi

WaveRunner 610Zi 620Zi

620 MZi

WaveRunner 625Zi 640Zi

Processor/CPUType Intel®E5300PentiumDualCore2.6GHzorgreaterProcessor Memory 2GBstandard,upto4GBoptionalOperatingSystem Microsoft Windows®7ProfessionalforEmbeddedSystems,64-bitRealTimeClock Dateandtimedisplayedwithwaveforminhardcopyfiles.SNTPsupporttosynchronizetoprecisioninternalclocks

InterfaceRemoteControl ViaWindowsAutomation,orviaTeledyneLeCroyRemoteCommandSetNetworkCommunicationStandard VXI-11orVICP,LXIClassC(v1.2)CompliantGPIBPort(Optional) SupportsIEEE—488.2(External)

Ethernet Port Supports10/100/1000Base-TEthernetinterface(RJ45port)USB Minimum4total(Including2frontpanel)USB2.0portssupportWindowscompatibledevicesUSBDevicePort 1USBTMCPortExternalMonitorPort 15-pinD-TypeSVGAcompatibleDB-15tosupportcustomer-suppliedexternalmonitor.

IncludessupportforextendeddesktopoperationwithWXGAresolutiononsecondmonitorPeripheralBus TeledyneLeCroyLBUSstandard

Power RequirementsVoltage 100–240VAC±10%at45–66Hz;100–120VAC±10%at380–420Hz;

AutomaticACVoltageSelection;InstallationCategory:300VCATIIPowerConsumption(Nominal) 400W/400VAMaxPowerConsumption 500W/500VA(withallPCperipherals,activeprobesconnected

to4channels,andMSOactive)

EnvironmentalTemperature(Operating) +5°Cto+40°CTemperature(Non-Operating) –20°Cto+60°CHumidity(Operating) 5%to80%relativehumidity(non-condensing)upto+31°C

Upperlimitderatesto50%relativehumidity(Non-condensing)at+40°CHumidity(Non-Operating) 5%to95%relativehumidity(non-condensing)astestedperMIL-PRF-28800FAltitude(Operating) Upto10,000ft.(3,048m)atorbelow+25°CRandomVibration(Operating) 0.31grms5Hzto500Hz,15minutesineachofthreeorthogonalaxesRandomVibration(Non-Operating) 2.4grms5Hzto500Hz,15minutesineachofthreeorthogonalaxesFunctional Shock 30 gpeak,halfsine,11mspulse,3shocks(positiveandnegative)ineachofthreeorthogonalaxes,18shockstotal

Physical DimensionsDimensions(HWD) 11.6929”Hx16.4567”Wx8.937”D(297x418x227mm)Weight 25.4lbs.(11.52kg)Shipping Weight 39lbs.(17.69kg)

CertificationsCECompliant,ULandcULlisted;ConformstoEN61326-1,EN61010-1,UL61010-12ndedition,and CSAC22.2No.61010-1-04

Warranty and Service3-yearwarranty;calibrationrecommendedannually.Optionalserviceprogramsincludeextendedwarranty, upgrades, and calibration services

Page 18: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

18

Standard

Math Tools

Displayupto8mathfunctiontraces(F1–F8).Theeasy-to-usegraphical interfacesimplifiessetupofuptotwooperationsoneachfunctiontrace, and function traces can be chained together to perform math-on-math.

absolute valueaverage(summed)average(continuous)correlation (twowaveforms)derivativedeskew(resample)difference(–)enhanced resolution (to11bitsvertical)envelopeexp(basee)

exp(base10)fft(powerspectrum,power average, magnitude, phase, upto128Mpts)floorintegralinterpolate(cubic,quadratic,sinx/x)invert(negate)log(basee)log(base10)

product(x)reciprocalrescale(withunits)roof(sinx)/xsparsesquaresquare rootsum(+)zoom(identity)

Measure Tools

Displayany8parameterstogetherwithstatistics,includingtheir average, high, low, and standard deviations. Histicons provide a fast, dynamic view of parameters and wave shape characteristics. Parameter Math allows addition, subtraction, multiplication, or division of two different parameters.

amplitudeareabasebit ratecyclesdelay∆delayduty cycledurationfalltime(90–10%, 80–20%,@level)frequencyfirstlast

level@xmaximummeanmedianminimumnarrow band phasenarrow band powernumber of points+overshoot– overshootpeak-to-peakperiodrisetime(10–90%, 20–80%,@level)

rmsstd. deviationtopwidthphasetime@minimum(min.)time@maximum(max.)∆time@level∆time@[email protected]@min.

Pass/Fail Testing

Simultaneously test multiple parameters against selectable parameter limitsorpre-definedmasks.Passorfailconditionscaninitiateactionsincludingdocumenttolocalornetworkedfiles,e-mailtheimageofthefail-ure,savewaveforms,sendapulseoutatthefrontpanelauxiliaryBNC out-put,or(withtheGPIBoption)sendaGPIBSRQ.

Standard (cont’d)

Basic Jitter and Timing Analysis

Thispackageprovidesjittertimingandanalysisusingtime,frequency, and statistical views for common timing parameters, and also includes other useful tools. Includes:

•“Track”graphsofallparameters,nolimitationofnumber

–Cycle-CycleJitter–N-Cycle–N-Cyclewith

start selection–Frequency@level

–Period@level– Half Period–Width@level–TimeInterval Error@level

– Setup– Hold– Skew–DutyCycle@level–DutyCycleError

• Edge@lvparameter(countsedges)•Histogramsexpandedwith19histogramparametersandupto 2billionevents

•Trend(datalog)ofupto1millionevents•Trackgraphsofallparameters•Persistencehistogram,persistencetrace(mean,range,sigma)

Advanced Customization

Provides capability to create a math function or measurement parameter inMATLAB,Excel,C++,JavaScript,orVisualBasicScript(VBS)formatandinsertitintotheoscilloscope’sprocessingstream.Allresultsarepro-cessed and displayed on the oscilloscope grid, and are available for further processing. Also permits the creation of customized plug-ins that can be insertedintothescopeuserinterface,controlofthescopeviaVisualBasicscriptsembeddedincustomizedfunctions,anduseofTeledyneLeCroy’sCustomDSOcapabilities.

Software Options

SDA II Serial Data Analysis Option (WR6Zi-SDAII)

Total Jitter

A complete toolset is provided to measure total jitter. Eye Diagrams with millionsofUIarequicklycalculatedfromupto128Mptsrecords,and advancedtoolsmaybeusedontheEyeDiagramtoaidanalysis.CompleteTIEandTotalJitter(Tj)parametersandanalysisfunctionsareprovided.•TimeIntervalError(TIE)MeasurementParameter,Histogram, SpectrumandJitterTrack

•TotalJitter(Tj)MeasurementParameter,Histogram,Spectrum•EyeDiagramDisplay(sliced)•EyeDiagramIsoBER(linesofconstantBitErrorRate)• Eye Diagram Mask Violation Locator• Eye Diagram Measurement Parameters

– Eye Height–OneLevel–ZeroLevel– Eye Amplitude

– Eye Width–EyeCrossing– Avg. Power–ExtinctionRatio

– Mask hits– Mask out–BitErrorRate– Slice Width (setting)

• Q-FitTailRepresentation• BathtubCurve• CumulativeDensityFunction(CDF)• PLLTrack

SPECIFICATIONS

Page 19: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

19

Software Options (cont’d)

SDA II Serial Data Analysis Option (WR6Zi-SDAII) - continued

Jitter Decomposition Models Twojitterdecompositionmethodsareprovidedandsimultaneouslycalculatedtoprovidemaximummeasurementconfidence.Q-Scale, CDF,BathtubCurve,andalljitterdecompositionmeasurement parameters can be displayed using either method.

• Spectral Method • NQ-ScaleMethodRandom Jitter (Rj) and Non-Data Dependent Jitter (Rj+BUj) • RandomJitter(Rj)MeasurementParameter • Rj+BUjHistogram • Rj+BUjSpectrum • Rj+BUjTrackDeterministic Jitter (Dj) • DeterministicJitter(Dj)MeasurementParameterData Dependent Jitter (DDj) • DataDependentJitter(DDj)MeasurementParameter • DDj Histogram • DDjPlot(byPatternorN-bitSequence)

Eye Doctor II Advanced Signal Integrity Tools (WM8Zi-EYEDRII)

Completesetofchannelemulation,de-embeddingandreceiverequaliza-tion simulation tools. Provides capability to emulate a serial data link, de-embedorembedafixture,cableorserialdatachannel,addorremoveemphasis,andperformCTLE,FFE,orDFEequalization.IfpurchasedwithSDAIII, then capabilities are accessed from within the SDAIII-Complete-LinQuserinterfaceframework.

Power Analyzer Option (WR6Zi-PWR)

Power switching device measurements, control loop modulation analysis, andlinepowerharmonictestingareallsimplifiedwithadedicateduserinterface and automatic measurements.Device Analysis • Losses – Automatic measurement of turn-on, turn-off, and conduction loses as well as off-state power, total losses and switching frequency • SafeOperatingArea • B-H-HysteresisCurve • DynamicOn-Resistance • Dv/dtanddi/vtControl Loop Analysis • Closedlooptime-domain–Dutycycle,width,periodorfrequencyLine Power Analysis • Power – Vrms, Irms, real-power, apparent power, power factor, crest factor • Harmonics–EN61000-3-2pre-compliance,TotalHarmonicDistortionMeasurement Setup • ControlsforDeskew,DCfineadjust,probeintegration,devicezoneidentification

Cable De-embedding Option (WR6Zi-CBL-DE-EMBED)

Removes cable effects from your measurements. Simply enter the S-parametersorattenuationdataofthecable(s)thenallofthefunctionalityoftheWR6Zicanbeutilizedwithcableeffectsde-embedded.

8b/10b Decode and 80-bit High Speed Serial Trigger Option (WR6Zi-80B-8B10B TD)

Intuitive, color-coded serial trigger decode with powerful search capability en-ablescapturedwaveformstobesearchedforuser-definedsequences of symbols. Multi-lane analysis decodes up to four simultaneously capturedlanes.Includes150Mb/sto3.125Gb/sHigh-speed80-bitSerialPatternTriggerOption

Software Options (cont’d)

Serial Data Mask Option (WR6Zi-SDM)

Createeyediagramsusingacomprehensivelistofstandardeyepatternmasks,orcreateauser-definedmask.Maskviolationsareclearlymarkedon the display for easy analysis.

Electrical Telecom Pulse Mask Test Option (WR6Zi-ET-PMT)

Performs automated compliance mask tests on a wide range of electrical telecom standards.

Spectrum Analyzer Option (WR6Zi-SPECTRUM)

SpectrumanalyzerstyleuserinterfaceandadvancedFFTcapabilities. •Automaticoscilloscopesetupwhenselectingstart/stopfrequencyor

center frequency and span• Resolution bandwidth automatically or manually controlled•FFTReferenceandverticalscaleindBm,dBV,dBmV,dBuV,VrmsorArms•Spectrogramprovides2Dor3Dspectralhistorydisplay•Upto100automaticpeakmarkers•Upto20markers,eithermanuallycontrolledorautomaticwhichmark

fundamental frequency and harmonics• Math waveform analysis, additional output types:

– Power density – Real – Imaginary – Magnitude squared

Disk Drive Measurements Option (WR6Zi-DDM2)

Thispackageprovidesdiskdriveparametermeasurementsandrelated mathematical functions for performing disk drive WaveShape Analysis.• Disk Drive Parameters are as follows:

– amplitude asymetry

– local base– local baseline

separation– localmaximum– local minimum– local number– local peak-peak– local time

between events– local time

between peaks– local time

between troughs

– local time at minimum

– local time atmaximum

– local time peak-trough

– local time over threshold

– local time trough-peak

– local time under threshold

– narrow band phase– narrow band power

– overwrite– pulsewidth50– pulsewidth50–– pulsewidth50+– resolution– track average

amplitude– track average

amplitude –– track average amplitude+

– auto-correlations/n– non-linear

transition shift

SPECIFICATIONS

Page 20: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

20

ORDERING INFORMATION

Product Description Product Code

WaveRunner 6 Zi Series Oscilloscopes400MHz,10GS/s,4Ch,16Mpts/ChDSOwith12.1"WXGAColorDisplay.50Ωand1MΩInput20GS/sand 32Mpts/ChinInterleavedMode

WaveRunner604Zi

600MHz,10GS/s,4Ch,16Mpts/ChDSOwith12.1"WXGAColorDisplay.50Ωand1MΩ Input 20GS/sand 32Mpts/ChinInterleavedMode

WaveRunner606Zi

1GHz,10GS/s,4Ch,16Mpts/ChDSOwith12.1"WXGAColorDisplay.50Ω and1MΩInput20GS/sand 32Mpts/ChinInterleavedMode

WaveRunner610Zi

2GHz,10GS/s,4Ch,16Mpts/ChDSOwith12.1"WXGAColorDisplay.50Ω and1MΩInput20GS/sand 32Mpts/ChinInterleavedMode

WaveRunner620Zi

2GHz,20GS/s,4Ch,64Mpts/ChDSOwith12.1”WXGAColorDisplay.50Ω and1MΩInput20GS/sand 128Mpts/ChinInterleavedMode

WaveRunner620MZi

2.5GHz,20GS/s,4Ch,16Mpts/ChDSOwith12.1"WXGAColorDisplay.50Ωand1MΩInput40GS/sand 32Mpts/ChinInterleavedMode

WaveRunner625Zi

4GHz,20GS/s,4Ch,16Mpts/ChDSOwith12.1"WXGAColorDisplay.50Ω and1MΩInput40GS/sand 32Mpts/ChinInterleavedMode

WaveRunner640Zi

Included with Standard Configuration÷10,500MHzPassiveProbe(Qty.4)Optical3-buttonWheelMouse,USB2.0PrintedQuickReferenceGuidePrinted Getting Started ManualProduct Manual in PDF Format on Oscilloscope DesktopAnti-virusSoftware(TrialVersion)Microsoft Windows®7forEmbeddedSystems64-bitLicenseCommercialNISTTraceableCalibrationwithCertificatePowerCablefortheDestinationCountry3-year Warranty

Oscilloscope Synchronization8ChannelSimultaneousAcquisition- CaptureandTransferWaveforms BetweenTwoWR6ZiOscilloscopes

WR6ZI-8CH-SYNCH

Product Description Product Code

Memory Options32Mpts/Ch(64Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR604Zi-S-32

32Mpts/Ch(64Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR606Zi-S-32

32Mpts/Ch(64Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR610Zi-S-32

32Mpts/Ch(64Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR620Zi-S-32

32Mpts/Ch(64Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR625Zi-S-32

32Mpts/Ch(64Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR640Zi-S-32

64Mpts/Ch(128Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR604Zi-M-64

64Mpts/Ch(128Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR606Zi-M-64

64Mpts/Ch(128Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR610Zi-M-64

64Mpts/Ch(128Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR620Zi-M-64

64Mpts/Ch(128Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR625Zi-M-64

64Mpts/Ch(128Mpts/ChInterleaved) StandardMemory.Includes4GB of RAM

WR640Zi-M-64

Page 21: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

21

ORDERING INFORMATION

Product Description Product Code

Memory and Sample Rate Options20GS/s(40GS/sInterleaved) SamplingRateOption

WR610Zi-STD-4x20GS

32Mpts/Ch(64Mpts/ChInterleaved)StandardMemory.Includes4GBofRAM.20GS/s(40GS/sInterleaved)SamplingRateOption

WR610Zi-S-32-4x20GS

64Mpts/Ch(128Mpts/ChInterleaved)StandardMemory.Includes4GBofRAM.20GS/s(40GS/sInterleaved)SamplingRateOption

WR610Zi-M-64-4x20GS

20GS/s(40GS/sInterleaved) SamplingRateOption

WR620Zi-STD-4x20GS

32Mpts/Ch(64Mpts/ChInterleaved)StandardMemory.Includes4GBofRAM.20GS/s(40GS/sInterleaved)SamplingRateOption

WR620Zi-S-32-4x20GS

64Mpts/Ch(128Mpts/ChInterleaved)StandardMemory.Includes4GBofRAM.20GS/s(40GS/sInterleaved)SamplingRateOption

WR620Zi-M-64-4x20GS

Computer UpgradeUpgradeFrom2GBRAMto4GBRAM WR6Zi-UPG-4GBRAMRemovableHardDriveOption WR6Zi-500GB-RHDAdditional500GBHardDrive forUseWithRHDOption.IncludesWindows7ProforEmbedded SystemsOS,TeledyneLeCroy OscilloscopeSoftwareandCriticalScopeOperationalFileDuplicates

WR6Zi-500GB-RHD-02

Serial Trigger and Decode8b/10bTriggerandDecodeOption WR6Zi-80B-8B10BTDARINC429BusSymbolic DecodeOption

WR6Zi-ARINCbusDSymbolic

AudiobusTriggerandDecodefor I2S,OptionLJ,RJ,andTDM

WR6Zi-AudiobusTD

AudiobusTrigger,Decode,andGraphOptionforI2S,LJ,RJ,andTDM

WR6Zi-AudiobusTDG

CANbusFDTriggerand DecodeOption

WR6Zi-CANFDbusTD

CANbusTDTriggerand DecodeOption

WR6Zi-CANbusTD

CANbusTDMTrigger,Decode andMeasure/GraphOption

WR6Zi-CANbusTDM

Decode Annotation and Protocol Analyzer Synchronization SoftwareOption

WR6Zi-ProtoSync

DigRF3GDecodeOption WR6Zi-DigRF3GbusDDigRFv4DecodeOption WR6Zi-DigRFv4busDENETDecodeOption WR6ZI-ENETbusDFibreChannelDecode AnnotationOption

WR6Zi-FCbusD

FlexRayTriggerandDecodeOption WR6Zi-FlexRaybusTDFlexRayTrigger,Decode,andPhysicalLayerTestOption

WR6Zi-FlexRaybusTDP

Product Description Product Code

Serial Trigger and Decode (cont’d)I2CBusTriggerandDecodeOption† WR6Zi-I2CbusTDI2C,SPIandUARTTriggerand DecodeOption†

WR6Zi-EMB

LINTriggerandDecodeOption WR6Zi-LINbusTDManchesterDecodeOption WR6ZI-ManchesterbusDMIL-STD-1553Triggerand DecodeOption

WR6Zi-1553TD

MIPID-PHYDecodeOption WR6Zi-DPHYbusDMIPI D-PHY Decode and Physical LayerTestOption

WR6Zi-DPHYbusDP

MIPIM-PHYDecodeOption WR6Zi-MPHYbusDMIPI M-PHY Decode and Physical LayerTestOption

WR6Zi-MPHYbusDP

MS-500-36withI2C,SPIandUARTTriggerandDecodeOption

WR6Zi-MSO-EMB

NRZDecodeOption WR6ZI-NRZbusDPCIExpressGen1DecodeOption WR6Zi-PCIebusDPROTObusMAGSerialDebugToolkit WR6Zi-PROTObusMAGSASDecodeAnnotationOption WR6Zi-SASbusDSATATriggerDecodeAnnotation OptionSupportsSATAGen1and2

WR6Zi-SATAbusTD

SENTBusDecodeOption WR6Zi-SENTDSPIBusTriggerandDecodeOption† WR6Zi-SPIbusTDUARTandRS-232Triggerand DecodeOption†

WR6Zi-UART-RS232busTD

USB1.x/2.0Trigger/DecodeOption WR6Zi-USB2busTDUSB2-HSICDecodeOption WR6Zi-USB2-HSICbusDVehicleBusAnalyzerPackage- IncludesCANBusTDM,FlexRayTDP,LINBusTD,andProtoBusMAG

WR6Zi-VBA

† IncludedwithWaveRunner620MZi

Serial Data ComplianceQualiPHYEnabledBroadR-Reach SoftwareOption

QPHY-BroadR-Reach

QualiPHYEnabledEthernet10/100/1000BTSoftwareOption

QPHY-ENET*

QualiPHYEnabledDDR2 SoftwareOption

QPHY-DDR2

QualiPHYEnabledDDR3 SoftwareOption

QPHY-DDR3

QualiPHYEnabledLPDDR2 SoftwareOption

QPHY-LPDDR2

QualiPHYEnabledMIPID-PHY SoftwareOption

QPHY-MIPI-DPHY

QualiPHYEnabledMOST150 SoftwareOption

QPHY-MOST150

QualiPHYEnabledMOST50 SoftwareOption

QPHY-MOST50

QualiPHYEnabledUSB2.0 SoftwareOption

QPHY-USB‡

10/100/1000Base-TEthernet TestFixture

TF-ENET-B**

USB2.0ComplianceTestFixture TF-USB-B

*TF-ENET-Brequired.‡TF-USB-Brequired. **IncludesENET-2CAB-SMA018andENET-2ADA-BNCSMA.

Page 22: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

22

Product Description Product Code

Serial Data AnalysisCableDe-EmbeddingOption WR6Zi-CBL-DE-EMBEDEyeDoctor(VirtualProbeand EqualizerEmulationBundle), Serial Data Analyzers, and Disk Drive Analyzers

WR6Zi-EYEDRII

SerialDataMaskSoftwareOption WR6Zi-SDMSDAIISerialDataAnalysisOption WR6ZI-SDAII

Mixed Signal Solutions250MHz,1GS/s,18Ch,10Mpts/ChMixedSignalOscilloscopeOption

MS-250

500MHz,2GS/s,18Ch,50Mpts/ChMixedSignalOscilloscopeOption

MS-500

250MHz,1GS/s,36Ch,25Mpts/Ch(500MHz,18Ch,2GS/s,50Mpts/ChInterleaved)MixedSignal OscilloscopeOption

MS-500-36

Data Storage SoftwareAdvancedOpticalRecording MeasurementOption

WR6Zi-AORM

Disk Drive Measurements SoftwareOption

WR6Zi-DDM2

DiskDriveAnalyzerSoftwareOption WR6Zi-DDA

Power Analysis SoftwarePowerAnalyzerSoftwareOption WR6Zi-PWR

Jitter Analysis SoftwareClockJitterAnalysiswithFourViewsSoftwareOption

WR6Zi-JITKIT

Spectrum Analysis SoftwareSpectrumAnalyzerOption (IncludedwithWaveRunner620MZi)

WR6Zi-SPECTRUM

Product Description Product Code

Other Software OptionsAdvancedCustomizationOption (IncludedwithWaveRunner620MZi)

WR6Zi-XDEV

EMCPulseParameter SoftwareOption

WR6Zi-EMC

ElectricalTelecomMaskTest SoftwareOption

WR6Zi-ET-PMT

Digital Filtering SoftwareDigitalFilterSoftwareOption (IncludedwithWaveRunner620MZi)

WR6Zi-DFP2

Remote Control/Network OptionsExternalUSB2toGPIBAdaptor USB2-GPIB

General Accessories OscilloscopeCartwith Additional Shelf and Drawer

OC1024

OscilloscopeCart OC1021Accessory Pouch WR6Zi-POUCHRackmount,8UAdaptorKit WR6ZI-RACKKeyboard,USB KYBD-1MILCalibrationCertification WR6Zi-CCMILSoftCarryingCase WR6Zi-SOFTCASEProtectiveHardCover WR6Zi-COVERHardCase WR6Zi-HARDCASEExternalAdaptorforReferenceInandOut(TobeappliedattheLbus Connector)

WR6Zi-ExtRef-IN/OUT

ORDERING INFORMATION

Page 23: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

23

Product Description Product Code

Probes÷10,500MHz10MΩ Passive Probe PP009÷10,500MHz10MΩ Passive Probe PP0081GHz,0.9pF,1MΩ High Impedance Active Probe

ZS1000

Setof4ZS1000,1GHz,0.9pF, 1MΩ High Impedance Active Probe

ZS1000-QUADPAK

1.5GHz,0.9pF,1MΩ High Impedance Active Probe

ZS1500

Setof4ZS1500,1.5GHz,0.9pF, 1MΩ High Impedance Active Probe

ZS1500-QUADPAK

2.5GHz,0.9pF,1MΩ High Impedance Active Probe

ZS2500

Setof4ZS2500,2.5GHz,0.9pF, 1MΩ High Impedance Active Probe

ZS2500-QUADPAK

4GHz,0.6pF,1MΩ High Impedance Active Probe

ZS4000

200MHz,3.5pF,1MΩ Active Differential Probe

ZD200

500MHz,1.0pF,1MΩ Active Differential Probe

ZD500

1GHz,1.0pF,1MΩ Active Differential Probe

ZD1000

1.5GHz,1.0pF,1MΩ Active Differential Probe

ZD1500

WaveLink4GHz,2.5Vp-pDifferentialProbe System

D410-PS

WaveLink4GHz,5Vp-pDifferentialProbeSystem

D420-PS

WaveLink4GHzDifferentialAmplifierModulewithAdjustableTip

D400A-AT*

WaveLinkProBusPlatform/Cable Assembly(4GHz)

WL-PBus-CASE

25MHzHighVoltageDifferentialProbe HVD3102120MHzHighVoltageDifferentialProbe

HVD3106

* Foracompleteprobe,orderaWL-PBUS-CASEPlatform/CableAssembly withtheAdjustableTipModule

Product Description Product Code

Probes (cont’d)1Ch,100MHzDifferentialAmplifierwith Precision Voltage Source

DA1855A

DA1855AwithRackmount DA1855A-RM2Ch,100MHzDifferentialAmplifierwith Precision Voltage Source

DA1855A-PR2

DA1855AwithRackmount (mustbeorderedattimeof purchase,noretrofit)

DA1855A-PR2-RM

30A;50MHzCurrentProbe– AC/DC;30Arms;50Apeak Pulse

AP015

30A;50MHzCurrentProbe– AC/DC;30Arms;50Apeak Pulse

CP030

30A;100MHzCurrentProbe– AC/DC;30Arms;50Apeak Pulse

CP031

150A;10MHzCurrentProbe– AC/DC;150Arms;500Apeak Pulse

CP150

500A;2MHzCurrentProbe– AC/DC;500Arms;700Apeak Pulse

CP500

700V,15MHzHigh-Voltage DifferentialProbe(÷10,÷100)

AP031

100:1400MHz50MΩ1kVHigh-voltage Probe

HVP120

10:1/100:1200/300MHz50MΩ High-VoltageProbe600V/1.2kV Max.Volt.DC

PPE1.2KV

100:1400MHz50MΩ2kV High-Voltage Probe

PPE2KV

100:1400MHz50MΩ 4 kV High-Voltage Probe

PPE4KV

1000:1400MHz50MΩ5kV High-Voltage Probe

PPE5KV

1000:1400MHz5MΩ / 50MΩ6kV High-Voltage Probe

PPE6KV

Optical-to-ElectricalConverter, 500-870nmProBusBNCConnector

OE425

Optical-to-ElectricalConverter, 950-1630nmProBusBNCConnector

OE455

ORDERING INFORMATION

Page 24: WaveRunner 6 Zi Oscilloscopes - atecorp.com · analysis for understanding and charac-terizing a design, proving compliance, and understanding why a device or host fails compliance

©2015byTeledyneLeCroy,Inc.Allrightsreserved.Specifications,prices,availability,anddeliverysubjecttochangewithoutnotice. Product or brand names are trademarks or requested trademarks of their respective holders. PCIExpress®isaregisteredtrademarkand/orservicemarkofPCI-SIG.MATLAB®isaregisteredtrademarkofTheMathWorks,Inc.Allotherproductorbrandnamesaretrademarksorrequestedtrademarks of their respective holders.

waverunner6zi-ds-06apr15

Local sales offices are located throughout the world. Visit our website to find the most convenient location.

1-800-5-LeCroy teledynelecroy.com