4
Endee provides a wide & extensive range of Water Quality Analyzer Products. These are Multi-parametric Instrument with complete range of Digital Sensors & Expandable as per requirement. It is also equipped with the MODBUS RTU protocol, Ethernet & Data logging. We provide this Analyzer with Inbuilt Graphic LCD Receiver which we can Monitor Reading of the Detected Parameters for further process of Control. WATER QUALITY ANALYZER COMPLETE AND FLEXIBLE SYSTEM FOR A WIDE RANGE OF APPLICATIONS IN WATER QUALITY MANAGEMENT APPLICATIONS Oil ,Food ,Chemical Industries Municipal Water Treatment Boiler Feed Water Oil Refineries Food Processing Wash Water Raw Water Plants Environmental Monitoring Monitoring of UV-Disinfection in Water Plants Sewage Treatment Plants Drinking Water Plant 1 ENDEE pH ORP Conductivity UVT Free Chlorine Turbidity Dissolved Oxygen BOD COD TOC MODEL NO:- WA-200

Water Quality Analyzer - endee-engineers.comendee-engineers.com/download/Online Wall Mounting Analyzer {WA-… · pH ORP Conductivity UVT Free Chlorine Turbidity Dissolved Oxygen

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Water Quality Analyzer - endee-engineers.comendee-engineers.com/download/Online Wall Mounting Analyzer {WA-… · pH ORP Conductivity UVT Free Chlorine Turbidity Dissolved Oxygen

Endee provides a wide & extensive range of Water Quality Analyzer Products. These are

Multi-parametric Instrument with complete range of Digital Sensors & Expandable as per requirement.

It is also equipped with the MODBUS RTU protocol, Ethernet & Data logging. We provide this

Analyzer with Inbuilt Graphic LCD Receiver which we can Monitor Reading of the Detected

Parameters for further process of Control.

WATER QUALITY ANALYZER

COMPLETE AND FLEXIBLE SYSTEM FOR A WIDE RANGE OF APPLICATIONS IN

WATER QUALITY MANAGEMENT

APPLICATIONS

Oil ,Food ,Chemical Industries

Municipal Water Treatment

Boiler Feed Water

Oil Refineries

Food Processing Wash Water

Raw Water Plants

Environmental Monitoring

Monitoring of UV-Disinfection in Water Plants

Sewage Treatment Plants

Drinking Water Plant

1

ENDEE

pH

ORP

Conductivity

UVT

Free Chlorine

Turbidity

Dissolved Oxygen

BOD

COD

TOC

MODEL NO:- WA-200

Page 2: Water Quality Analyzer - endee-engineers.comendee-engineers.com/download/Online Wall Mounting Analyzer {WA-… · pH ORP Conductivity UVT Free Chlorine Turbidity Dissolved Oxygen

2

SPECIAL FEATURES

Graphic Display with LCD Resolution of 320×240:

This allows the Simultaneous Display of Digital Measurement.

Internal Data logger:

With possibility to store up to 4,00,00,000 Records & Display Stored Data. Data Download

to USB PENDRIVE or through RS 485.

Programmable Analog Outputs:

For Repeating the Measurements, with the First & Second Set on the Measurement of the

Same Parameter.

Accepted Digital Input:

MODBUS RTU for Set-up, Real Time Data Communication or Download of the Stored Data.

Field-Replaceable Sensors:

Easy to Replace Sensors as per requirement on Fields.

Expandable Range of Sensor:

Whole Range of Sensors is available as per requirement & the Product Engineered to Function

normally in Applications.

SPECIFICATION

Type

Electronic / Processor

Detectable Parameters

Technology

Power Supply

Display

Display Resolution

Alarm

Digital Output

Digital Input

Analog input

Analog Output

Operating Temp.

Humidity

Housing / Case

Protection Class

Wireless Data Transfer

Weight

Dimensions

Wall mount

Micro-controller

pH, ORP, Conductivity, BOD, COD, TOC, Turbidity, UVT,

Free Chlorine, Chlorine Dioxide, Nitrates, Dissolved Oxygen

Sensor Specific

230VAC, 50Hz

Graphic LCD

320 X 240

4 nos Alarm relays

RS 485, MODBUS, Data logging in external USB drive, Ethernet

RS 485- MODBUS, 4-20 mA

4-20 mA

4-20 mA

0 ~ 55ºC

5% to 90% Rh (non-condensing)

ABS Hi-Impact Plastic

IP 65

ZIGBEE

4.5 Kg

270 x 240 x 150 (LBH)

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

Page 3: Water Quality Analyzer - endee-engineers.comendee-engineers.com/download/Online Wall Mounting Analyzer {WA-… · pH ORP Conductivity UVT Free Chlorine Turbidity Dissolved Oxygen

3

MEASURES

DIGITAL pH and ORP ELECTRODES:Digital pH and ORP Electrodes are typically a combination type, which contains two Electrodesone is Measuring Electrode and other is Reference Electrode. Digital pH & ORP Electrode is usedin applications such as Drinking Water, Process Water, Waste Water etc. Measurement Range: 0 - 14 pH and -1500 mV to +1500 mV Temperature Range: 0 - 100 °C Pressure Range: 0 - 100 PSIG

DIGITAL DIFFERENTIAL pH and ORP ELECTRODE:Digital Differential pH and ORP Electrodes have employs a Field-Proven method that uses threeElectrodes instead of the two Differential Ph Sensors provide measurements of Greater Stabilityover longer periods of time with less downtime and maintenance. Differential Electrode is usedin Industrial heavy duty applications such as Biological Treatment of Waste Water. Measurement Range: 0 - 14 pH and -1500 mV to +1500 mV Temperature Range: 0 - 100 °C Pressure Range: 0 - 100 PSIG

CONDUCTIVITY:A conductivity Meter measures the amount of Electrical Current or Conductance in a solution.Conductivity Meter is commonly used in Hydroponics, Aquaculture and Fresh Water Systemsto Monitor the amount of Nutrients, Salts or Impurities in the Water. It is useful in determiningthe overall health of a Natural Water body. Measurement Range: 0 - 2,000,000 uS/cm Temperature Range: 0 - 200 °C Pressure Range: 0 - 250 PSIG

FREE CHLORINE:Free Chlorine measurements ensure an adequate amount of Chlorine is available for Disinfectionpurposes, and in some cases the chlorine has been removed. Free chlorine feature Amperometricmeasurement technology. It is useful in applications such as Swimming Pool, Drinking Water,Process Water. Measurement Range: 0 - 2 PPM, 0 - 5 PPM, or 0 - 10 PPM Free Chlorine Temperature Range: 0 - 45 °C Pressure Range: 0 - 14.7 PSIG

SENSOR CONTROLLER ARRANGEMENT

ENDEE

Page 4: Water Quality Analyzer - endee-engineers.comendee-engineers.com/download/Online Wall Mounting Analyzer {WA-… · pH ORP Conductivity UVT Free Chlorine Turbidity Dissolved Oxygen

Note : Images shown are indica�ve only. Specifica�ons and Features will vary with applica�on. There may be changes over�me due to con�nuous development process.

@ 2018

4

CHLORINE DIOXIDE:In the Water Industry Chlorine Dioxide is disinfection methods measurements under dosage canbe ineffective and over dosage results in excess Chlorine by product formation. It is extremelyeffective in controlling legionella. It is useful in pre-oxidant for Drinking water, Cooling waterdisinfections Measurement Range: 0 - 2 PPM, 0 - 5 PPM, or 0 - 10ppm Chlorine Dioxide Temperature Range: 0 - 45 °C Pressure Range: 0 - 14.7 PSIG

UVT:Amount of Natural Organic Matter (NOM) in the water sample is measured by UV Transmittance.UV Disinfection performance optimizing in Wastewater, Dose control in Drinking/Processing water,Size and design of UV Disinfection systems, Selection of the optimal disinfection treatment process,Micro pollutant removal efficiency of wastewater treated with ozone. Measurement Range: 10% - 100% Output: 4 - 20 mA Power Requirement: 24 VDC Wavelength: 254 nm

DISSOLVED OXYGEN:Dissolved Oxygen (DO) is the amount of oxygen dissolved in a unit of water is measured bygalvanic sensor technology. It is useful in Fish farming and Aquatic environment health, Live fishtransport, Corrosion control. Measurement Range: 0 - 100% or 0 - 200% Dissolved Oxygen Temperature Range: 0 - 50 °C Power Requirement: 12 - 36 VDC

BOD, TOC & COD:BOD, TOC, COD is vital test for assessing the quality of effluents and waste water prior to dischargeusing UV LED technology. It is used for monitoring and control of discharges and for accessingtreatment plant performance. Measurement Range: 0 - 1000 mg/L Temperature Range: 5 - 40 °C Pressure Range: 30 bar

NITRATES:Nitrate in water is undetectable without testing because it is Colorless, Odorless, and Tasteless.A water test for nitrate is highly recommended. Nitrate-nitrogen occurs naturally in groundwater.An initial test of a new water supply is needed to determine the baseline nitrate concentration. Measurement Range: 0 - 100 mg/L Temperature Range: 2 - 80 °C Pressure Range: 30 bar

TURBIDITY:With the use of a 90° Scatter Light Measurement, this Turbidity System provides high-sensitivitymeasurement with Zero Stability. With this Particular Monitor you can acquire Data-logging. Measurement Range: 0 - 4000 NTU Temperature Range: 0 - 60 °C Pressure Range: 4 bar

ENDEE ENGINEERS PVT. LTD.Office & Works : D/122, Ansa Industrial Estate, Saki-Vihar Road, Saki-Naka, Andheri (E),

Mumbai - 400 072, Maharashtra, India. | Tel.: +91-22-4295 2180 / 81

Email : [email protected]