Endee provides a wide & extensive range of Water Quality Analyzer Products. These are
Multi-parametric Instrument with complete range of Digital Sensors & Expandable as per requirement.
It is also equipped with the MODBUS RTU protocol, Ethernet & Data logging. We provide this
Analyzer with Inbuilt Graphic LCD Receiver which we can Monitor Reading of the Detected
Parameters for further process of Control.
WATER QUALITY ANALYZER
COMPLETE AND FLEXIBLE SYSTEM FOR A WIDE RANGE OF APPLICATIONS IN
WATER QUALITY MANAGEMENT
APPLICATIONS
Oil ,Food ,Chemical Industries
Municipal Water Treatment
Boiler Feed Water
Oil Refineries
Food Processing Wash Water
Raw Water Plants
Environmental Monitoring
Monitoring of UV-Disinfection in Water Plants
Sewage Treatment Plants
Drinking Water Plant
1
ENDEE
pH
ORP
Conductivity
UVT
Free Chlorine
Turbidity
Dissolved Oxygen
BOD
COD
TOC
MODEL NO:- WA-200
2
SPECIAL FEATURES
Graphic Display with LCD Resolution of 320×240:
This allows the Simultaneous Display of Digital Measurement.
Internal Data logger:
With possibility to store up to 4,00,00,000 Records & Display Stored Data. Data Download
to USB PENDRIVE or through RS 485.
Programmable Analog Outputs:
For Repeating the Measurements, with the First & Second Set on the Measurement of the
Same Parameter.
Accepted Digital Input:
MODBUS RTU for Set-up, Real Time Data Communication or Download of the Stored Data.
Field-Replaceable Sensors:
Easy to Replace Sensors as per requirement on Fields.
Expandable Range of Sensor:
Whole Range of Sensors is available as per requirement & the Product Engineered to Function
normally in Applications.
SPECIFICATION
Type
Electronic / Processor
Detectable Parameters
Technology
Power Supply
Display
Display Resolution
Alarm
Digital Output
Digital Input
Analog input
Analog Output
Operating Temp.
Humidity
Housing / Case
Protection Class
Wireless Data Transfer
Weight
Dimensions
Wall mount
Micro-controller
pH, ORP, Conductivity, BOD, COD, TOC, Turbidity, UVT,
Free Chlorine, Chlorine Dioxide, Nitrates, Dissolved Oxygen
Sensor Specific
230VAC, 50Hz
Graphic LCD
320 X 240
4 nos Alarm relays
RS 485, MODBUS, Data logging in external USB drive, Ethernet
RS 485- MODBUS, 4-20 mA
4-20 mA
4-20 mA
0 ~ 55ºC
5% to 90% Rh (non-condensing)
ABS Hi-Impact Plastic
IP 65
ZIGBEE
4.5 Kg
270 x 240 x 150 (LBH)
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
3
MEASURES
DIGITAL pH and ORP ELECTRODES:Digital pH and ORP Electrodes are typically a combination type, which contains two Electrodesone is Measuring Electrode and other is Reference Electrode. Digital pH & ORP Electrode is usedin applications such as Drinking Water, Process Water, Waste Water etc. Measurement Range: 0 - 14 pH and -1500 mV to +1500 mV Temperature Range: 0 - 100 °C Pressure Range: 0 - 100 PSIG
DIGITAL DIFFERENTIAL pH and ORP ELECTRODE:Digital Differential pH and ORP Electrodes have employs a Field-Proven method that uses threeElectrodes instead of the two Differential Ph Sensors provide measurements of Greater Stabilityover longer periods of time with less downtime and maintenance. Differential Electrode is usedin Industrial heavy duty applications such as Biological Treatment of Waste Water. Measurement Range: 0 - 14 pH and -1500 mV to +1500 mV Temperature Range: 0 - 100 °C Pressure Range: 0 - 100 PSIG
CONDUCTIVITY:A conductivity Meter measures the amount of Electrical Current or Conductance in a solution.Conductivity Meter is commonly used in Hydroponics, Aquaculture and Fresh Water Systemsto Monitor the amount of Nutrients, Salts or Impurities in the Water. It is useful in determiningthe overall health of a Natural Water body. Measurement Range: 0 - 2,000,000 uS/cm Temperature Range: 0 - 200 °C Pressure Range: 0 - 250 PSIG
FREE CHLORINE:Free Chlorine measurements ensure an adequate amount of Chlorine is available for Disinfectionpurposes, and in some cases the chlorine has been removed. Free chlorine feature Amperometricmeasurement technology. It is useful in applications such as Swimming Pool, Drinking Water,Process Water. Measurement Range: 0 - 2 PPM, 0 - 5 PPM, or 0 - 10 PPM Free Chlorine Temperature Range: 0 - 45 °C Pressure Range: 0 - 14.7 PSIG
SENSOR CONTROLLER ARRANGEMENT
ENDEE
Note : Images shown are indica�ve only. Specifica�ons and Features will vary with applica�on. There may be changes over�me due to con�nuous development process.
@ 2018
4
CHLORINE DIOXIDE:In the Water Industry Chlorine Dioxide is disinfection methods measurements under dosage canbe ineffective and over dosage results in excess Chlorine by product formation. It is extremelyeffective in controlling legionella. It is useful in pre-oxidant for Drinking water, Cooling waterdisinfections Measurement Range: 0 - 2 PPM, 0 - 5 PPM, or 0 - 10ppm Chlorine Dioxide Temperature Range: 0 - 45 °C Pressure Range: 0 - 14.7 PSIG
UVT:Amount of Natural Organic Matter (NOM) in the water sample is measured by UV Transmittance.UV Disinfection performance optimizing in Wastewater, Dose control in Drinking/Processing water,Size and design of UV Disinfection systems, Selection of the optimal disinfection treatment process,Micro pollutant removal efficiency of wastewater treated with ozone. Measurement Range: 10% - 100% Output: 4 - 20 mA Power Requirement: 24 VDC Wavelength: 254 nm
DISSOLVED OXYGEN:Dissolved Oxygen (DO) is the amount of oxygen dissolved in a unit of water is measured bygalvanic sensor technology. It is useful in Fish farming and Aquatic environment health, Live fishtransport, Corrosion control. Measurement Range: 0 - 100% or 0 - 200% Dissolved Oxygen Temperature Range: 0 - 50 °C Power Requirement: 12 - 36 VDC
BOD, TOC & COD:BOD, TOC, COD is vital test for assessing the quality of effluents and waste water prior to dischargeusing UV LED technology. It is used for monitoring and control of discharges and for accessingtreatment plant performance. Measurement Range: 0 - 1000 mg/L Temperature Range: 5 - 40 °C Pressure Range: 30 bar
NITRATES:Nitrate in water is undetectable without testing because it is Colorless, Odorless, and Tasteless.A water test for nitrate is highly recommended. Nitrate-nitrogen occurs naturally in groundwater.An initial test of a new water supply is needed to determine the baseline nitrate concentration. Measurement Range: 0 - 100 mg/L Temperature Range: 2 - 80 °C Pressure Range: 30 bar