V&T-2900CUVBanknote Counting Machine

Service Manual2010.05.13

Page 2: V&T 2900CUV Service Manual(New Board) 2010513

Table of content1. Introduction to Boards------------------------------------------------------------------------------------------- 1

1.1 Main board --------------------------------------------------------------------------------------------------- 1

2. Parameter Adjustment ----------------------------------------------------------------------------------------- 2

2.1 Adjusting IR Sensors -------------------------------------------------------------------------------------- 2

2.2 Adjusting UV Sensors-------------------------------------------------------------------------------------- 3

3. Advance Setting---------------------------------------------------------------------------------------------------4

4. Trouble shooting---------------------------------------------------------------------------------------------------5

This document is the property of V&T (Wei Ke) Co., LTD.Any unauthorized reproduction is prohibited.

Page 3: V&T 2900CUV Service Manual(New Board) 2010513

V&T-2900CUV Service Manual

1. Introduction to Boards1.1 Main Board:

VR3 VR2

VR1

T6T16

CHIP

T24

Page 4: V&T 2900CUV Service Manual(New Board) 2010513

V&T-2900CUV Service Manual

2. Parameter AdjustmentTooling set includes: UV Testing paper, White testing paper.2.1 Adjusting IR Sensors: 1. Putting the any paper on the Currency Slippery Plank to block the Stacker sensor. 2. Power on the V &T 2900CUV -- The counting display will show “E23”

3. Putting the white testing paper in the machine to block the all sensor.

Caution: Be sure the white testing paper blocks in the middle position to cover all

the IR sensors. 4. Set the multi-meter measure method according to the parameter.

Test the testing point.

Calibrate the variable resister to the standard parameter value.

Caution: Be sure the upper cover is close before adjusting the sensors.

Parameter Type Parameter Value Variable Resistor T5 :+ Voltage 2.2V VR2

T3 :+ Voltage 2.2V VR1

Page 5: V&T 2900CUV Service Manual(New Board) 2010513

V&T-2900CUV Service Manual

2.2 Adjusting UV Sensors: 1. Putting the any paper on the Currency Slippery Plank to block the Stacker sensor. 2. Power on the V &T 2900CUV -- The counting display will show “E23” 3. Putting the UV testing paper in the machine to block the all sensor. (no particle UV testing paper is above in the machine)

Caution: Be sure the UV testing paper blocks in the middle position to cover LED.

4. Set the multi-meter measure method according to the parameter.

Test the testing point.

Calibrate the variable resister to the standard parameter value.

Caution: Be sure the upper cover is close before adjusting the sensors.

Parameter Type Parameter Value Variable Resistor T6 :+ Voltage 1.2V VR3

Page 6: V&T 2900CUV Service Manual(New Board) 2010513

V&T-2900CUV Service Manual

3. Advance Setting a. The way to enter the advance setting. Press and hold the “UV” Key, then power on the machine to enter the Advance Setting. “UV” + Power on the machine

b. The function of each key in this modeKey FunctionUV Increase number

Batch Change itemADD Decrease number

c. The counting screen display:Screen Item Default

JU Fluorescent Sensitivity 7JC Breadth Sensitivity 7Jd Double Sensitivity 3

d. The setting : 1. Fluorescent Sensitivity

The sensitivity level of Fluorescent SensitivityThe range of the setting is 1~12. (Default: 7)The higher value means higher sensitivity.

2. Breadth SensitivityThe sensitivity level of Breadth SensitivityThe range of the setting is OFF~12. (Default: 7)The OFF means disable the Breadth detection.The higher value means higher sensitivity.

3. Double SensitivityThe sensitivity level of Double SensitivityThe range of the setting is OFF~7. (Default: 3)The OFF means disable the Double detection.The higher value means higher sensitivity.

Page 7: V&T 2900CUV Service Manual(New Board) 2010513

V&T-2900CUV Service Manual

e. Default (factory) Setting: The way to enter the Default Setting Press and hold “ADD” Key and Power on the machine

and then Press “RESTART” Key. “ADD” + Power on the machine + “RESTART”

Page 8: V&T 2900CUV Service Manual(New Board) 2010513

V&T-2900CUV Service Manual

4. Trouble shootingEvents and relevant remedies:

The machine fails

to power on.

(1) The Transformer faulty. Change the Transformer (03-002)

(2) The Electric Capacity is faulty.Change the Electric Capacity (03-003)

(3) The connector or connection line

is loose.Check all the connectors and connection lines.

(4) The Fuse is faulty Change the Fuse

(5) The main board is faulty Replace the power board (01-001).

The motor fails to

rotate.

(1) The motor is faulty. Replace the motor (03-001).

(2) The rotation speed sensor is

faulty

Replace the rotation speed sensor is

faulty (02-001)

The machine is miscount

(1) Adjusting gap screw See user ‘s manual

(2) Adjusting IR sensorsSee parameter Adjustment

(3) The Drive Currency Wheel and Resistance Mat Slice are to wear out

Change the Drive Currency Wheel and Resistance Mat Slice

(04-001 04-003)

(4) The counting notes is not correct Again the feeding notes

Page 9: V&T 2900CUV Service Manual(New Board) 2010513

V&T-2900CUV Service Manual