Viwa 90Viwa 115Viwa 125Viwa 150
Product Brochure
Wall-Hung Type Premix System
Condensing Boiler
Everybody Deserves a Warmhaus
WARMHAUS PRODUCTS HEAT HOUSES AND BUILDINGS IN MORE THAN 35 COUNTRIES.
WARMHAUS EXPORTS %60 OF ITS PRODUCTION TO THE
REST OF TE WORLD.
About Warmhaus
Warmhaus is an affilate of Beyçelik Holding which produces boilers, high capacity wall hung consending boilers and steel panel radiators with more than 23 years experience in heating industry.
OUR PRODUCTION LINES ARE EQUIPPED WITH MODERNIZED AUTOMATION SYSTEMS.
Ĥ 27.500 sqm panel radiator production facility
Ĥ 8.000 sqm boiler production facility
Ĥ Exports to more than 35 countries
Ĥ Annual panel radiator production capacity of 2.700.000 meters
Ĥ Annual boiler production capacity of 150.000 units
Ĥ 3.000 sqm warehouse and sales office in United Kingdom
Ĥ Among ISO Second 500 Largest Corporations List
With modernised production lines and high quality products; Warmhaus warms houses and buildings in more than 35 countries.
Warmhaus UK3000 sqm warehouseand sales o�ce
2
OUR PRODUCTS ARE CERTIFIED BY INTERNATIONAL INSTITUTIONS TO MEET THE HIGHEST INDUSTRY STANDARDS.
WARMHAUS IS AMONGST THE TOP 10 RADIATOR PRODUCERS IN THE WORLD, AND THE TOP 4 IN TURKEY.
THANKS TO THE MODERN WAREHOUSE,
FAST DELIVERY WITH THE AUTOMATED
SHELVING SYSTEM.
Warmhaus UK3000 sqm warehouseand sales o�ce
Ĥ Algeria Ĥ Argentina Ĥ Armenia Ĥ Azerbaijan Ĥ Belarus Ĥ Belgium Ĥ Bulgaria Ĥ Canada
Ĥ Chile Ĥ China Ĥ Denmark Ĥ England Ĥ France Ĥ Georgia Ĥ Germany Ĥ Greece
Ĥ Hungary Ĥ Iraq Ĥ Ireland Ĥ Italy Ĥ Kosovo Ĥ Macedonia Ĥ Moldova Ĥ Mongolia
Ĥ New Zealand Ĥ Northern Cyprus Ĥ Poland Ĥ Portugal Ĥ Romania Ĥ Russia Ĥ Scotland Ĥ Serbia
Ĥ Spain Ĥ Tunisia Ĥ Ukraine Ĥ Uzbekistan Ĥ Wales
Global Heating Brand
Products developed by Warmhaus R&D center are shipped all over the world.
3
11 Reasons to Choose Viwa Boiler
Viwa90-115-125-150 kW
Perfect Body Insulation High usage efficiency is ensured thanks to 10 mm thick insulation which prevents heat loss from boiler body and decreases sound level.
Built-in Cascade Control UnitBuilt-in Cascade Module control unit provides connection and communication between boilers without needing additional devices. So each boiler can be used as master or slave.
Perfect Heat Transfer Aconit® BurnerThe Aconit® burner with excellent heat transfer is specially designed for maximum utilization of the heat exchanger surface. Thanks to its wide modulation rate and low surface temperature it provides highest performance and lowest NOx emission.
4
Easy and Quick installation with Smart Plug System Easy and quick cascade installation up to eight boilers with to built-in cascade unit and smart plug system.
Built-in Air & Dirt SeparatorBuilt-in mini Air & Dirt Separator and additional air separator on the exhaust manifold prevent air and particle in the system from damaging the exchanger.
Compatibility with different cascade control panelsWarmhaus Viwa boilers are able to communicate with OpenTherm communication protocol and work with various cascade control systems available in the market.
Cascade Installation up to 14 x 150 = 2100 kWIt is also possible to build cascade system without cascade control unit up to 14 boilers and 2100 kW.
Al-Si-Mg Alloyed Monobloc ExchangerAl-Si-Mg alloyed exchanger is more efficient compared to stainless steel and highly resistant to corrosion.
Multiple Part ManagementWith an optional MLC 30 module 4 direct heating circuit and hot water tank or 1 low temperature zone, one high temperature zone and one tank circuit can be controlled.
Installation to Limited Space With Compact Dimensions W:615 x D:490 x H:720 mm
Compact dimensions and adjacent installation capability allows installation with limited spaces.
Hermetic Flue Connection Warmhaus Viwa boilers have room sealed hermetic boiler design and compatible with Ø100/150 mm concentric flue connection. Each boiler can be used with its own flue sets independent from each other which makes cascade systems easy to install in roof spaces without a stainless steel flue.
H
D W
5
Dimensions
490 mm615 mm
720 mm
1. LCD Screen2. Reset Button3. Temperature Increase Button 4. Temperature Decrease Button5. Summer Mode Button6. Winter Mode Button7. Mode Button8. Lo Button9. Chimney Button10. Info Menu Button11. Hi Butonu
5 4 6
2
10
11
1
7
8
3
9
The Smallest and Lightest Boiler in Its Segment: Viwa 150
6
Components
Long Lasting and Smooth Use With High-Quality Components
Condensation Tank
CH Flow Connection
Gas Connection
Pressure Sensor
Supply Sensor
Automatic Air Relief Valve
Ignition Electrode
Air and Gas Measurement Points
Strainer discharge point
CH Return Connection
Exchanger Body Protection Sensor
Heat Exchanger
Return Sensor
Flue Sensor
Frame
Flue Connection Ø100/150
Gas Valve
Automatic Air Relief Valve
6 Bar Safety Valve
Fan
TRAP: Mini air and particle strainer
7
Accessory Code Accessory Name Explanation Matching Product Product View
153.11.660.600001 WDHS-01 Outside Sensor
Sensor which regulates boiler according to outside air temperature. Viwa 50-150
153.11.660.600045 RC 21.11 Timer Room Thermostat
Thermostat which sets to apply weekly/ daily program to heater and boiler unit or a unite which can only be used as program clock.
Viwa 50-150
153.11.660.600049
QAZ 36 Immersion Boiler / Hydraulic Separator Sensor
Immersion Sensor which is used to measure DHW storage tanks or Hydraulic Separator Temperature and transfers information to boiler.
Viwa 50-150
153.11.660.600050QAD 36 Strap-on Temperature Sensor
Strap-on Temperature Sensor for connection on pipe at the output of hydraulic separator. It is used to measure flow water temperature of second zone at the double heating zone.
Viwa 50-150
153.11.660.600053MST80 Calibrated Surface Thermostat
Pipe clamp type adjustable for heating zone thermostat Viwa 50-150
153.11.660.600047 MLC 30 Multiple Zone Module
Unit which controls the low temperature of Viwa 90, Viwa 115, Viwa 125 and Viwa 150 boilers / underfloor heating zone (blend valve circuit ).
Viwa 50-150
153.11.660.600071 QAC 34 Outside Sensor
Mandatory if RVS unit is used. Regulates boiler according to outside temperature. Viwa 50-150
Control Accessories for Cascade System
8
Pump Set Accessories
WILO -Yonos PARA
High pressure and flow rate pump for Warmhaus Viwa wall hung boilers.
Pump set with frequency inverter for Viwa 90, 115 and 125.
Pump set with frequencyInverter for Viwa 150.
1. 1 1/2" TESNIT® Seal
2. Pump Union 1½” - 1¼”
3. 11/4" Check Valve
4. 1"-11-4" Pump Reduction
5. 1"-11-4" Nipple
6. Pump Union 1 ½”
7. Pump
1. 1 1/2" TESNIT® Seal
2. Pump Union 1½” - 1¼”
3. 1 1/4" Check Valve
4. 1 1/4" Nipple
5. Pump Union 1¼” - 2"
6. 2" TESNIT® Seal
7. Pump
READY
Pump Sets (Optional)High pressure and flow rate pump for Warmhaus Viwa wall hung boilers.
Accessory Code Accessory Name Explanation Matching Product
152.11.003.000002Viwa 90, Viwa 115 and Viwa 125 Pump Set with frequency inventors
Wilo-YONOS PARA HF 25/7 pump set with modulation, 2 connectors, check valve and seal set for Viwa 90, Viwa 115 and Viwa 125. It is installed just below the boilers.
152.11.003.000003 Viwa 150 Pump Set with frequency Inventors
Wilo-YONOS PARA HF 25/10 pump set with modulation, 2 connectors, check valve and seal set for Viwa 150. It is installed just below the boilers.
34
3 m
m
150 kW Kazan Pompa Grubu
36
0 m
m
90-115-125 kW Kazan Pompa Grubu
34
3 m
m
150 kW Kazan Pompa Grubu
36
0 m
m
90-115-125 kW Kazan Pompa Grubu
Pump Set for Viwa 90, Viwa 115
and Viwa 125
Pump Set for Viwa 150
9
Accessory Code Accessory Name Explanation Matching Product
153.11.014.000007 Ø 100/150 Horizontal Flue Set
Maximum Flue Distance
Lmax= 18 m (Viwa 90) Lmax= 17 m (Viwa 115)Lmax= 17 m (Viwa 125) Lmax= 10 m (Viwa 150)
153.11.660.600042 Ø 100/150 Flue Extension L=500 mm
It can be used with Horizontal Flue Set and Vertical Funnel Set.
153.11.660.600043 Ø 100/150 Flue Extension L=1000 mm
It can be used with Horizontal Flue Set and Vertical Flue Set.
153.11.660.600040 BOB 100.100 Flue Check Valve
This is an accessory that must be installed at the outlet of each boiler when multiple boilers are used in the cascade system. The boiler connection and the collector connection are Ø100 mm.
153.11.660.600068 BOB 100.100 Flue Check Valve
When more than one boiler is used in cascade system, it is the accessory which must be install each boiler chimney outlet. The boiler connection and the collector connection are Ø100 mm.
153.11.660.600044 Ø 100/150 Bend (90°)It can be used with Horizontal Flue Set and Vertical Flue Set. Each 90° bend usage requires 100 cm decreasing from maximum horizontal / vertical distance.
153.11.660.600041 Ø 100/150 Vertical Flue Set
Maximum Flue Distance
Lmax= 20 m (Viwa 90) Lmax= 20 m (Viwa 115)Lmax= 19 m (Viwa 125) Lmax= 11 m (Viwa 150
Flue Accessories can be installed each other by meshing method so any additional part is not required to connection.
C53
C53
Flue Connection Types
Flue Accessories
Discharge with concentric flue connection
C83
Discharge to building chimney and fresh air intake with separate flue connection
C
Exhaust gas discharge through building chimney and fresh air intake with separate flue sets
Exhaust gas discharge and fresh air intake with concentric flue kit and separate flue kits
Exhaust gas discharge and fresh air intake with separate flue kits
Exhaust gas discharge through building chimney and fresh air intake from inside of the building with separate flue sets.
C13 C33C33
AirExhaust gas
B23
10
COLD
W
ATER
Res
ircul
atio
n pu
mp
Stro
ge T
ank
Pum
p
Stro
ge T
ank
Sens
or2
x 1.0
mm
2
Syst
em P
ump
3 x
1.0 m
m2
BOIL
ER
ELEC
TRIC
AL
PAN
EL
Boi
ler
pane
l and
El
ectr
ical
Pan
el c
onne
ctio
n fo
r Sy
stem
Pum
p 3
x 1.0
mm
2
Boi
ler
pane
l and
El
ectr
ical
Pan
el re
lay
conn
ectio
n fo
r Sy
stem
Pum
p 3
x 1.0
mm
2
Out
side
Sen
sor
2 x
1.0 m
m2
Tim
er/R
oom
Th
erm
osta
t2
x 1.0
mm
2
FLU
EO
UTL
ET
GA
S LI
NE
Pum
p C
able
3 x
1.0 m
m2
1. Zo
ne +
Str
oge
Tank
Tim
er/R
oom
The
rmos
tat
RESIRCULATION CIRCUIT
COLD
W
ATER
Rad
iato
r Circ
uit V
iwa
and
A H
ot W
ater
Sup
ply
conn
ectio
n di
agra
m w
ith
Viw
a 90
/ V
iwa
150
boi
ler
1. B
oile
r2.
G
as S
afet
y So
leno
id V
alve
3.
Bal
l Val
ve4.
G
as F
ilter
5.
Vib
ratio
n Is
olat
or6.
C
onde
nsat
e Si
phon
and
D
rain
age
Line
7.
Che
ck V
alve
8.
Boi
ler (
Ret
urn)
Pum
p9.
A
utom
atic
Air
Purg
e Va
lve
10. S
edim
ent-
Dirt
-Air
Sepa
rato
r11
. M
anom
eter
13. H
ydra
ulic
Sep
arat
or
14. S
edim
ent-
Dirt
Sep
arat
or
15. H
eatin
g Sy
stem
Ste
am
Wat
er C
olle
ctor
16. H
eatin
g Sy
stem
Ret
urn
Wat
er C
olle
ctor
17.
Hea
ting
Syst
em P
ump
18. H
eatin
g Sy
stem
19
. Pre
ssur
e R
educ
er
20. H
ot W
ater
Tan
k21
. Hot
Wat
er T
ank
Pum
p22
. Hot
Wat
er T
ank
Sens
or23
. Air
Sepa
rato
r24
. Hot
Wat
er T
ank
Rec
ircul
atio
n Li
ne25
. Rec
ircul
atio
n Pu
mp
26. S
afet
y Va
lve
27. E
xpan
sion
Tan
k28
. Filt
er29
. Tim
er/R
oom
The
rmos
tat
30. B
oile
r Ele
ctric
al P
anel
31. O
utsi
de A
ir S
enso
r
INST
ALL
ATIO
N E
QU
IPM
ENT
Sample Installation Scheme
Single Boiler Scheme
11
Out
side
Sen
sor
Prog
ram
able
Roo
m
Ther
mos
tat
for
1. Zo
ne a
nd
Stro
ge T
ank
Prog
ram
able
R
oom
The
rmos
tat
for
2. Z
one
FLU
E O
UTL
ETFL
UE
OU
TLET
FLU
E O
UTL
ET
14. B
oile
r/Sl
ave
2. B
oile
r/Sl
ave
1. B
oile
r/M
aste
r
Pum
pca
ble
Pum
pca
ble
Hyd
raul
ic
Sepa
rato
r Se
nsor
COLD
WAT
ER
FOR
FIL
LIN
G
COLD
WAT
ER
FOR
FIL
LIN
G
RECIRCULATION CIRCUIT
Stor
age
Tank
Uni
t Te
mpe
ratu
re P
robe
Stro
ge T
ank
Pum
p
Mix
er
Valv
eLT
Stro
ge T
ank
- Pu
mp
Boi
ler
Pane
l Rel
ay C
onne
ctio
n
Low
Tem
pera
ture
Zon
e Pu
mp
LT
Rec
ircul
atio
n Pu
mp
Syst
em
Pum
pH
T
Prog
ram
able
Roo
m
Ther
mos
tat
Prog
ram
able
Roo
m
Ther
mos
tat
Low
Tem
pera
ture
Sys
tem
Pum
p B
oile
r Pa
nel R
elay
Con
nect
ion
Syst
em P
ump
- B
oile
r Pa
nel
Rel
ay C
onne
ctio
n
Elec
tric
al P
anel
To e
nsur
e co
mm
unic
atio
n be
twee
n bo
ilers
, co
mbi
ne b
oile
r 1 c
able
and
boi
ler
2 B
cab
le.
ATTE
NTI
ON
: OPT
ION
AL
MLC
30
USE
D.
See
Figu
re 2
.42
for
MLC
30
Con
nect
ion
Viw
a 90
, 115
, 125
and
150
Boi
lers
and
Cas
cade
Sys
tem
and
M
ulti-
Zone
Sys
tem
Con
nect
ion
Dia
gram
ATTE
NTI
ON
: If t
here
is n
ot a
ny s
enso
r sl
eeve
pla
ce in
hyd
raul
ic s
epar
ator
at
casc
ade
syst
em "
QA
D 3
6 Su
rfac
e Ty
pe -
Syst
em O
ngoi
ng S
enso
r "
mus
t be
use
d.
1. B
oile
r2.
Gas
Saf
ety
Sole
noid
Val
ve3.
Bal
l Val
ve4.
Gas
Filt
er5.
Vib
ratio
n Is
olat
or6.
Con
dens
ate
Siph
on a
nd D
rain
age
Line
7. C
heck
Val
ve8.
Boi
ler (
Ret
urn)
Pum
p
9. A
utom
atic
Air
Purg
e Va
lve
10. S
edim
ent-
Dirt
-Air
Sepa
rato
r11
. Man
omet
re12
. Hyd
raul
ic S
epar
ator
Sen
sor
13. H
ydra
ulic
Sep
arat
or14
. Sed
imen
t-D
irt S
epar
ator
15. H
eatin
g Sy
stem
Ste
am W
ater
Col
lect
or16
. Hea
ting
Syst
em R
etur
n W
ater
Col
lect
or
17. H
eatin
g Sy
stem
Pum
p18
. Hea
ting
Syst
em19
. Pre
ssur
e R
educ
er20
. Hot
Wat
er T
ank
21. H
ot W
ater
Tan
k Pu
mp
22. H
ot W
ater
Tan
k Se
nsor
23. A
ir Se
para
tor
24. H
ot W
ater
Tan
k
Rec
ircul
atio
n Li
ne25
. Rec
ircul
atio
n Pu
mp
26. S
afet
y Va
lve
27. E
xpan
sion
Tan
k28
. Filt
er29
. Tim
er/R
oom
The
rmos
tat
30. B
oile
r Ele
ctric
al P
anel
31. O
utsi
de S
enso
r
32. L
ow T
empe
ratu
re Z
one
Sens
or33
. 3-W
ay M
otor
ized
Val
ve34
. MLC
30
- O
PTIO
NA
L K
IT35
. Low
Tem
pera
ture
Zon
e
INST
ALL
ATIO
N E
QU
IPM
ENT
Sample Installation Scheme
Cascade System Scheme
12
Technical Data
All information given in the brochure was obtained as a result of the tests. The data may be changed without prior notice.
Technical Table Unit Viwa 90 Viwa 115 Viwa 125 Viwa 150
Gas Circuit
Gas type *(Doğal Gaz G20) Isı Yükü (Hu=10,56 kWh/m3) G20 G20 G20 G20
Gas supply pressure mbar 20
Gas Consumption at Maximum m³/h 9,301 11,55 12,737 15,27
Gas Consumption at Minimum m³/h 1,538 1,787 2,005 2,419
Premix System Pneumatic
Modulation Range 1:6
Heat Exchanger Material Al-Mg-Si
Efficiency G20 G20 G20 G20
(80/60 °C) Efficiency at Maximum Heat Output % 97,2 97,5 97,8 97,6
(50/30 °C) Efficiency at Maximum Heat Output % 103,6 102,7 103,6 103,0
Efficiency at 30% load at 36/30 °C % 107,5 107,2 108,0 107,5
Seasonal Heating Energy Efficiency (given in GCV) % 92 (Class A)
Radiator Circuit G20 G20 G20 G20
Maximum heat input Qn kW 90 115 125 150
Minimum heat input Qn kW 14,5 17,5 20 24
Maximum Heat Output Pn (80/60 0C) kW 87,9 112 122,2 146,3
Minimum Heat Output Pn (80/60 0C) kW 13,2 15,4 17,8 21,6
Maximum Heat Output Pn (50/30 0C) kW 93,2 118 129 154,5
Minimum Heat Output Pn (50/30 0C) kW 16,1 19,0 20,8 25,1
Temperature selection range (min÷max) high temperature 0C 25÷80
Temperature selection range (min÷max) low temperature 0C 25÷47
Operating Pressure (Maximum) bar 6
Operating Pressure (Minimum) bar 0,8
Domestic Hot Water Circuit
Temperature adjustment range 0C 20 - 65
Electricity Circuit
Electricity Supply V AC–50 Hz 230 V +%10; -%15
Electricity Consumption (Max./Min.) Watt 29 / 120 30/ 128 29 / 169 30 / 265
Protection Index IP IPX5D
Exhaust Gas Circuit G20 G20 G20 G20
(80/60 °C) Exhaust gas temperature (Min. / Max.) 0C 53,5 / 61,7 52,5 / 67,8 56,4 / 58,7 56,9 / 67,6
(50/30 °C) Exhaust gas temperature (Min. / Max.) 0C 30,4 / 46,3 31,2 / 50,2 30,1 / 46,6 30,2 / 48,0
NOx Class 6
Weighted value of Nox (GCV) mg/kWh 18 28 25 29
Flue mass flow rate (60/80°C - Qn) Nominal/Minimum g/s 38,89 / 6,43 48,29 / 7,47 53,25 / 8,38 63,84 / 8,38
General
Dimensions (H x W X D) mm 720 x 615 x 490
Sound Level dB (A ) 62,1 62,1 63,4 63,4
Net Weight kg 70 70 82 82
Packed Device Weight kg 87 87 99 99
Type B23, C13, C33, C53, C63, C83
Category I2H/I2E/I2E(S)
13
Warmhaus Technical Trainings
During our training, our partners receive detailed information about the topics below:
Ĥ Operation Principles of Boilers
Ĥ Type of Boiler Technologies
Ĥ General Features of Warmhaus Boilers
Ĥ Operation Principles of Warmhaus Boilers
Ĥ Components of Warmhaus Boilers
Ĥ Differentiation points of Warmhaus Boilers
We support our business partners with comprehensive trainings and technical documentation.
Please visit our production site. All attendees receive a certificate at the end of the training.
All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request.
14
15
REV
3-W
H-3
03-
BR
O-2
020
022
5-IN
T
Everybody Deserves a Warmhaus
[email protected] warmhaus.com
Management Office
Nidakule Ataşehir Kuzey Barbaros Mah. Begonya Sok. No: 3 K: 19 D: 170-175 34746, Ataşehir / İstanbul / Turkey
T +90 216 300 16 50
Boiler Factory
Işıktepe OSB Mah. Park Cad. No: 10 16140, Nilüfer / Bursa / Turkey
Radiator Factory
Minareliçavuş OSB Mah. Selvi Cad. No: 3 16140, Nilüfer / Bursa / Turkey
T +90 224 295 94 00 F +90 224 411 23 77
United Kingdom (Subsidiary)
Unit 7, St Martins Business Centre St Martins Way, Bedford MK42 0LF, England
T +44 207 164 6233 F +44 207 000 1336