Vivid E95 product datasheet – June 2015 – DOC1564269 Page 1 of 19 Ease of use for the operator in 2D imaging is provided by the cSound technology delivering auto optimized excellent image quality with minimal manipulation along with automated tools like 2D Auto EF, AFI Productivity Package, AFI Stress and Scan Assist Pro. Ergonomic features include a highly portable user-adaptable design with electronic adjustable height and keyboard, articulating and height adjustable monitor, and lightweight transducers combining to make the Vivid E95 an ergonomic-friendly cardiovascular ultrasound system. The cSound platform takes GE’s Raw Data to a new level. For image process- ing and reconstruction, the Vivid E95 utilizes more than 100 times the data compared to its predecessor. Additionally, the Vivid E95 uses an innovative data format technology that allows for advanced processing on archived images by applying many of the same scan controls and advanced quantitative tools as are available during the original exam. General Specifications Dimensions and Weight • Width: 544 mm, 21 3/4" • Depth: 844 mm, 33 1/4" • Height: 1230 mm – 1670 mm, 48 3/8" – 65 3/4" (up/down mechanism + LCD arm) • Weight: 126 kg , 278 lbs Electrical Power • Nominal input voltage: 100-240 VAC, 50/60 Hz • Typical power consumption: 500 W @ default cardiac preset with M5Sc • Rated power consumption: 700 W System Architecture GE’s exclusive, programmable and flexible beamforming technology, cSound, provides exceptional image quality and power compared to conventional GE hardware-based beamforming technology. In 2D, cSound offers true confocal imaging without the limitation of focal zones or sacrifice of frame rate and spatial resolution. In 4D, cSound delivers high spatial resolution at large volume sizes in full volume single-beat and multi-beat 4D acquisition. Using both coherent and harmonic image processing, the system provides computational power, ease of imaging, workflow flexibility and product upgradeability. The Vivid E95 is designed to excel in the following areas: Exceptional image quality is created through the use of True Confocal Imaging. The technique is enabled by the cSound platform taking advantage of advanced software-based image reconstruction and state-of-the-art graphics computer technology. The Vivid E95 combines Ultra Definition Clarity filtering, HD Imaging (optimal resolution, penetration and image uniformity), Adaptive Contrast Enhancement (ACE) and virtual apex (wide field-of-view) to deliver excellent cardiovascular ultrasound image quality. Probe Technology – The XDclear series of probes are designed to help deliver powerful and efficient sound waves, with high bandwidth and efficiency. XDclear probe technology provides impressive deep penetration and high sensitivity while maintaining high spatial resolution. The combination of Single Crystal, Acoustic Amplifier and Cool Stack technologies is the core technology of the XDclear series of probes. Vivid E95 Product Description The Vivid E95 combines the proven breadth, quality and performance of the Vivid product line with a new and innovative software-based image processing platform: cSound. The Vivid E95 is GE cardiovascular ultrasound’s leadership scanner.. The system is designed to excel in adult 2D and 4D cardiac imaging, as well as in the following clinical application areas: pediatric cardiac, fetal/obstetrics, abdominal (including renal, GYN/pelvic), pediatrics, small organ (including breasts, testes and thyroid), adult and neonatal cephalic, peripheral vascular, musculoskeletal conventional, urology/ prostate, transesophageal, transrectal, transvaginal and intraoperative (including vascular, thoracic/cardiac and abdominal). Vivid E95 is delivered with a high-quality 22" high-resolution wide screen OLED monitor for optimal spatial and dynamic resolution.

Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

  • Upload
    domien

  • View
    226

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 1 of 19

Ease of use for the operator in 2D imaging is provided by the cSound technology delivering auto optimized excellent image quality with minimal manipulation along with automated tools like 2D Auto EF, AFI Productivity Package, AFI Stress and Scan Assist Pro.

Ergonomic features include a highly portable user-adaptable design with electronic adjustable height and keyboard, articulating and height adjustable monitor, and lightweight transducers combining to make the Vivid E95 an ergonomic-friendly cardiovascular ultrasound system.

The cSound platform takes GE’s Raw Data to a new level. For image process-ing and reconstruction, the Vivid E95 utilizes more than 100 times the data compared to its predecessor.

Additionally, the Vivid E95 uses an innovative data format technology that allows for advanced processing on archived images by applying many of the same scan controls and advanced quantitative tools as are available during the original exam.

General Specifications

Dimensions and Weight• Width:544mm,213/4"

• Depth:844mm,331/4"

• Height:1230mm–1670mm, 483/8"–653/4" (up/downmechanism+LCDarm)

• Weight:126kg,278lbs

Electrical Power• Nominalinputvoltage: 100-240VAC,50/60Hz

• Typicalpowerconsumption:500W @ default cardiac preset with M5Sc

• Ratedpowerconsumption:700W

System Architecture GE’s exclusive, programmable and flexible beamforming technology, cSound, provides exceptional image quality and power compared to conventional GE hardware-based beamforming technology. In 2D, cSound offers true confocal imaging without the limitation of focal zones or sacrifice of frame rate and spatial resolution. In 4D, cSound delivers high spatial resolution at large volume sizes in full volume single-beat and multi-beat 4D acquisition. Using both coherent and harmonic image processing, the system provides computational power, ease of imaging, workflow flexibility and product upgradeability.

The Vivid E95 is designed to excel inthefollowingareas:

Exceptional image quality is created through the use of True Confocal Imaging. The technique is enabled by the cSound platform taking advantage of advanced software-based image reconstruction and state-of-the-art graphics computer technology. The Vivid E95 combines Ultra Definition Clarityfiltering,HDImaging(optimalresolution, penetration and image uniformity),AdaptiveContrast Enhancement(ACE)andvirtualapex(widefield-of-view)todeliverexcellent cardiovascular ultrasound image quality.

Probe Technology – The XDclear™ series of probes are designed to help deliver powerful and efficient sound waves, with high bandwidth and efficiency. XDclear probe technology provides impressive deep penetration and high sensitivity while maintaining high spatial resolution. The combination of Single Crystal, Acoustic Amplifier and Cool Stack technologies is the core technology of the XDclear series of probes.

Vivid E95

Product DescriptionThe Vivid™ E95 combines the proven breadth, quality and performance of the Vivid product line with a new and innovative software-based image processingplatform:cSound.™ The Vivid E95 is GE cardiovascular ultrasound’s leadership scanner..

The system is designed to excel in adult 2D and 4D cardiac imaging, as well as inthefollowingclinicalapplicationareas: pediatriccardiac,fetal/obstetrics, abdominal(includingrenal,GYN/pelvic), pediatrics, small organ (including breasts,testesandthyroid),adultandneonatal cephalic, peripheral vascular, musculoskeletalconventional,urology/prostate, transesophageal, transrectal, transvaginal and intraoperative (including vascular,thoracic/cardiacandabdominal).

Vivid E95 is delivered with a high-quality 22"high-resolutionwidescreen OLEDmonitorforoptimalspatialanddynamic resolution.

Page 2: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 2 of 19

Operating System• Windows®7

Console Design• Fiveactiveprobeports

• ECGport

• IntegratedHDD

• MultipleUSBports(front/back)

• IntegratedDVD-Rmultidrive(optional )

• On-boardstorageforB/W thermal printer

• Integratedspeakersfor premium sound

• Integratedlockingmechanismthatprovides rolling lock and caster swivel lock

• Integratedcablemanagement

• Easilyaccessibleremovable air filters for cleaning

• Frontandrearhandles

• Sidestoragetrays

• Rearstoragetrays/baskets

• Handrest

User Interface

Operator Keyboard• Floatingkeyboardadjustablein threedimensions:

- Height

- Rotation

- Extension

• Touchkeyboardwithsupportforcharacters in 12 languages

• Drawertype,lit,A/Nkeyboard

• SupportforEuropeankeyboard charactersets(ISO8859)

• Ergonomichardkeylayout

• Interactivebacklighting

• Integratedgelholders

• User-configurableprobeholders

• Easy-to-learnuserinterface

• Dedicatedrotaryforoverallgain for 2D-mode

• DedicatedgainrotaryforM-mode,CFM or Doppler controlled by active mode

• Neonatalhead

• Smallparts

• Thyroid

• Breast

• Musculoskeletal

• IntraOperative

• Transcranial

• Scrotal

• Urology(incl.pelvic)

• Rodent ( incl.ratsandmiceforresearch)

• Transesophageal

• OB/GYN

• Coronary

• Contrast(optional)

• ContrastlowMI(optional)

• LVOcontrast

Operating Modes• 2Dtissue

• 4Dtissue

• 2Dcolorflow

• 4Dcolorflow

• 2Dangioflow

• ColorM-mode

• TissuevelocityM-mode

• ContinuouswaveDoppler

• TissueM-mode

• PulsedwaveDoppler

• AnatomicalM-mode

• CurvedanatomicalM-mode

• Tissuevelocityimaging

• Tissuetracking

• Tissuesynchronizationimaging (optional )

• Strainimaging(optional )

• Strainrateimaging(optional )

• TissuevelocityDoppler

• Bloodflowimaging

• Bloodflowangioflowimaging

• B-flow

• 2Dstress(optional )

• AFIAutomatedFunctionImaging(optional )

• AutoEF(optional )

• Imagemanageronthetouch screen for quick review of image clipboard contents

Touch Screen• 12"ultra-high-resolution,widescreenformat,color,multi-touchLCDscreen

• Interactiveuser-configurable dynamic software menu

• Backlightadjustment–automaticbylight sensor or manual

• Touch-panelcontrolscontentcan be set to routine or extended usage

LCD Monitor• 22"widescreenHigh-Definition(HD)flicker-freeOLEDdisplay

• 256shadesofgrayand16.7millionsimultaneous colors available

• Articulatedmonitorarm

• LCDtranslation (independentofconsole):

- 350mmhorizontalbidirectional

- 150 mm vertical height adjustment

- Swivel to any viewing direction

• Folddownandrotationlock mechanism for transportation

• Horizontalviewinganglewider than170°

• Resolution:1920x1080px

• Automaticormanualdigitalbrightness and contrast adjustment for optimal viewing in different ambient light conditions(light-sensor)

• Tintandbacklightadjustments

• Separateadjustmentforexternalmonitorbrightness/contrast

System Overview

Probe Presets• Cardiac

• Stress(incl.Exercise,QStressand LVOStress)(optional )

• Abdominal( incl.renal)

• Vascular(incl.carotid,LEA,LEV,UEA,UEV,aorto-Iliac)

• Fetalheart

• Pediatric

• Neonatal

Page 3: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June2015–DOC1564269 Page3of19

• 2Dvirtualapeximaging

• Bi-plane

• Tri-plane

• Bi-andtri-planewithcolor

• Codedphaseinversionandpowermodulation contrast imaging

• Compoundimaging

• Extendedfield-of-view(LOGIQView)

• 4Dfullvolumescanning– single-beat and multi-beat

• 4Dstress

• 4Dstrainimaging(optional )

Scanning Methods• Electronicsector

• Electronicvolume

• Electronicconvex

• Electroniclinear

• CWpencil

Transducer Types• Sectorphasedarray

• Convexarray

• Lineararray

• Singlecrystalmatrixarray

• 2Dmatrixarray

Standard 4D Features• Single,dualormultiplecycle

volume acquisition

• Bi-planeacquisitionincludestilt and rotate, and bi-plane prepare

• Tri-planeacquisition

• Multi-dimensional (bi-plane/tri-plane)coloracquisition

• Dynamicmulti-sliceviews

• Livemulti-sliceviews

• FlexiSlicewithdepthmode

• 4Dstress

• Multi-dimensionalstress

• QuickRotate/Rotate

• Autocrop

• 2-clickcrop

• Flipcrop

• Viewcrop

• Opticalisolationcable–DVI104fiberoptic extender, required to connect theSony3DmonitorforPolarVision(polarizedstereovisiondisplay)

External outputs

• DVI-I

• Ethernet–10Mbps,100Mbps, 1 Gbps

• MultipleUSB2.0ports

Display Modes• Liveandstoreddisplayformat:

Full size and split screen, both with thumbnails, for still and cine

• Instant-reviewscreendisplays12 simultaneousloops/imagesforaquick study review

• Selectabledisplayconfigurationofduplexandtriplexmodes:side-by-side or top-bottom during live, digital replay and clipboard image recall

• Single,dualandquad-screenview

• Simultaneouscapability

- 2D+PW/CW

- 2D+CFM/TVI+PW

- 2D+CFM+CW

- 2D+CFM/Angio/TVI/SRI/TT/SI/TSI

- 2D+M/AMM/CAMM

- 2D+CFM/Angio/TVI/SRI/TT/SI/TSI+M/AMM/CAMM

- Real-timeduplexortriplexmode

- Compound+M/CFM/PW

- 4D+CFM

- 2D+bi-plane

- 2D+bi-plane+CFM/TVI/SRI/TT/SI/TSI/AMM/CAMM

- 2D+tri-plane

- 2D+tri-plane+CFM/TVI/SRI/TT/SI/TSI/AMM/CAMM

- 2D+colorsplitscreen (simultaneousmode)

• Selectablealternatingmodes

- 2Dorcompound+PW

- 2D+CW

- 2Dorcompound+CFM/PW

- 2D+CFM+CW

• Multi-image(split/quadscreen)

- Liveand/orfrozen

- Independent cine playback

• Dynamicviewcrop

• Measurementonrender

• FlexiZoom

• Stereovision

• LaserLines

• Depthcolorrender

• AutomaticLValignment

• 4Dvirtualapex

• Automated4Dleftventricular quantification(LVvolumeandEF)

Optional 4D Features• 4DAutoAVQ:Automated4Daortic

annulus quantification (dimension, area,circumference)

• 4DAutoLVQ:Automated4D left ventricular quantification (volume,ejectionfraction)

• 4Dstrain

• 4DLVmass

• 4Venable (requiredtorun4V-Dprobe)

• HDlive

• MVassessment(Tomtec)

• RVvolume(Tomtec)

• Polarizedstereovision

Peripheral Options• Consoleprotectivecover

Internal peripherals

• USBB/Wvideoprinterwithcontrolfrom system (optional)

External peripherals

• DirectstreamingDVR (Sony®HVO-550MD)

• Networkprinters

- USBinkjetprinter

- Color laser printer

- Color video printer with control from system

• 16GBencryptedmemorystick

• 2TBUSBharddrive(2x2TB SATA II hard drives mirrored for dataredundancy)

• Three-pedalconfigurablefootswitch

Page 4: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 4 of 19

• Timelinedisplay

- Independent2D(orcompound)+PW/CW/Mdisplay

- A choice of display formats with varioussizesof2D+PW/CW/M

• Top/bottomselectableformat

• Side/sideselectableformat

• 4Ddisplay

- Two+onesliceandrenderview

- Quadview(three-sliceandrender)

- Single render view

- Slice-only view

- Dynamic multi-slice

- Livemulti-slice

- FlexiSlice(liveandreplay)

- Bi-planeside/sideview

- Tri-plane view (quad including geometryviewer)

- Crop view (threeorthogonalslice+render)

- Apical slice view (three60degreesview+render)

- Cine rotate render view

- Bi-planeprepare (two-slice+render)

Display Annotation• Patientname:First,lastandmiddle

• PatientID

• AdditionalpatientID

• Age,sexandbirthdate

• Hospitalname

• Dateformat:Twotypesselectable– MM/DD/YY,DD/MM/YY

• Timeformat:Twotypesselectable– 24 hours, 12 hours

• GestationalagefromLMP/EDD/GA

• Probename

• Mapnames

• Probeorientation

• Depthscalemarker

• Imagedepth

• Zoomdepth

• B-mode

- Gain

- Imaging frequency

- Frame averaging

• 4Dsliceintersectionmarkers

• 4Dgauge

• 4Dviewinganglearrows

• 4Dgeometryviewer

• 4Dnumberofcycles

• Scanplanepositionindicatorandprobe temperature are displayed with all TEE probes

• Imageorientationmarker

General System Parameters

System Setup• Pre-programmableM&A and

annotation categories

• User-programmablepresetcapabilitywith administrator preset protection

• Factorydefaultpresetdata,protected against modification

• User-definedannotations

• Bodypatterns

• Customizedcommenthomeposition

Comprehensive User Manual Available on Board Available through touch-panel utility page. User manual and service manual areincludedonaUSBmemorydevice with each system. A printed user manual is provided.

• Usermanuallanguages:English,French, German, Spanish, Italian, Portuguese(EuropeanandBrazilian),Swedish,Danish,Dutch,Norwegian,Japanese, Chinese, Polish, Finnish, Greek,Russian,Hungarian,Slovak,Romanian,Czech,Latvian,Lithuanian, Turkish, Estonian, Korean, Serbian, Bulgarian,Croatian,Indonesian,Kazakh, Ukraine

CINE Memory/Image Memory• 8GBofRAM (0.5GBusedforcinememory)

• Selectablecinesequencefor cine review

• Measurements/calculationsand annotations on cine playback

• Scrollingtimelinememory

• M-mode

- Gain

- Frequency

- Time scale

• Dopplermode

- Gain

- Angle

- Sample volume size and position

- Wallfilter

- Velocityand/orfrequencyscale

- Spectrum inversion

• Timescale

- PRF

- Doppler frequency

• ColorflowDopplermode

- Frame rate

- Sample volume size

- Color scale

- Power

- Color baseline

- Color threshold marker

- Color gain

• Spectruminversion

• Acousticframerate

• CINEgauge,imagenumber/framenumber

• Bodymarks:Multiplehuman anatomical structures

• Application/presetname

• Measurementresults

• Operatormessage

• Displayedacousticoutput

- TIS:ThermalIndexSoftTissue

- TIC:ThermalIndexCranial(Bone)

- TIB:ThermalIndexBone

• MI:Mechanicalindex

• PoweroutputindB

• Biopsyguidelineandzone

• Heartrate

• Trackball-drivenannotationarrows

• Activemodedisplay

• Stressprotocolparameters

• Parameterannotationfollow ASE standard

• Freetextwithwordlibrary

Page 5: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 5 of 19

• Dual-imagecinedisplay

• Quad-imagecinedisplay

• CINEgaugeandcineimage number display

• CINEreviewloop

• CINEreviewspeed

Image Storage• 4Dvirtualstoreforefficient

4D image management

• On-boarddatabaseofpatient information from past exams

• User-selectableECGandtime gated acquisition available on touch panel during live

• User-selectableprospectiveor retrospective capture in config

• Storageformats:

- DICOM®-compressed or uncom-pressed,single/multi-frame, with/withoutrawdata,storageviaclipboardand/orseamlesslydirectly to destination device

- Transfer/“SaveAs”JPEG,MPEG,AVI,DICOM,RawDICOMand VolDicom formats

• Storagedevices:

- USBmemorystick:16GB

- CD-RWstorage:700MB (DVDoptionrequired)

- DVDstorage:-R(4.7GB) (DVDoptionrequired)

- Harddriveimagestorage:0.5TB

• Compareoldimageswith current exam

• Reloadofarchiveddatasets

• ActivationcontrolofUSBdevices (forsecurity)

Connectivity and DICOM • Ethernetnetworkconnection

• DICOM3.0

• Verify

• Print

• Store

• Modalityworklist

• Storagecommitment

• ModalityPerformedProcedureStep(MPPS)

• Imageclipboardforstamp-size storage and review of stored images and loops

• Built-inpatientarchivewith images/loops,patientinformation,measurements and reports

• DICOM-SRStandardstructured reporting mechanism

• Structuredfindingsreporttoolssupport efficient text entries with direct editing of findings text, usability improvements, new configuration options and conclusion section

• Usercanenternormalvalues which are then compared to actual measurements

• ConfigurableHTML-based report function

• Reporttemplatescanbecustomizedon board

• ASE-baseddefaulttextmodules (English),user-customizable

• Internalarchivedatacanbe exported to removable image storage through DICOM media

• Internalharddisk–forstoring programs, application defaults, ultrasound images and patient archive

• Alldatastorageisbasedon ultrasound raw data, allowing to change gain, baseline, color maps, sweep speeds, etc., for recalled images and loops

• DICOMmedia–read/writeimages on DICOM format

• DICOMviewerembeddedonmedia(optionalandselectableinConfig)

• AlphanumericdatacanbeexportedinXMLformat

• JPEGexport(“SaveAs”)forstillframes

• AVIandMPEGexport(“SaveAs”) for cineloops

• Specializedfileformat“SaveAs” VolDICOM feature to allow data importintoTomTecResearch Arena free-standing workstation

• Mediaexchange

• DICOMspooler

• DICOMquery/retrieve

• Structuredreporting–compatiblewith adult cardiac and vascular

• Mediastoreofstructuredreporting

• InSite™ ExC capability for remote service/access

• Supportoftwopatients’IDsinDICOM

• SeparateDICOMSRandimage storage destinations

• SimultaneoustransferofDICOMtomultiple destinations

Patient ArchiveEchoPAC™/Patient Archive• IntegratedEchoPACfunctionality

adds connectivity and image analysis capability to scanner

• DataformatfullycompatiblewithofflineEchoPACreview/reporting stations of same or newer vintage

• Instantaccesstoultrasoundrawdata provided by the system

• Advancedpost-processinganalysis

• Threeuserlevelshelporganizingdata security requirements

• E-signoffcompatibility,withclearindications in patient management screens and report screen that a report was signed off, and by whom and at what time. The signed off report and exam cannot be changed. The“DiagnosingPhysician”fieldisautomatically assigned to the user that did the sign-off

Image and Data Management• Exceptionalworkflowwithinstant

access data management

• DICOM3.0support–seeDICOM conformance statement for details

• Supportfortransferoftheproprietary raw data files within the DICOM standard

• 2D,CFMorTVIdataatmaximumframe rate may be reviewed by scrolling or by running cine loops (can contain more than 1000 images forimagingmodes)

Page 6: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 6 of 19

Insite™ Express Connection (ExC) Enables Remote Service and Training

• Easy,flexibleandsecureconnectiv-ityconfiguration.The“ContactGE”on-screen button directly generates a real-time service request to the GE online engineering or application specialist. It takes a snapshot (e.g.,errorlogs,setupfiles)ofthe system at the time of the service request to enable analysis of problem before customer contact

• VirtualConsoleObservation(VCO) enables the customer to allow desktop screens to be viewed and controlled remotely over the encrypted tunnel to enable real-time training, device configuration and clinical application support

• OperationofInsiteExpressConnection is dependent on the infrastructure being available – check with your local GE service representative

• Filetransferenablesthecustomer(biomedorclinician)todirectlytransfer system information (e.g., system logs,images,parametricdata)to GE product engineering teams (nopatientdatatransferred)

• Softwarereloadprovidesremote application reconstruction and recovery capabilities in the event of system corruption

Scanning Parameters• Infinitenumberofeffectivechannels

• Minimumfield-of-viewrange(depth):0–2cm(zoom)(probedependent)

• Maximumfield-of-viewrange(depth):0–50cm(probedependent)

• Widthrange:10–120degrees

• Continuousdynamicreceivefocus/continuous dynamic receive aperture

• Continuousdynamictransmitfocus

• Adjustabledynamicrange,infiniteupper level

• Imagereverse:Right/left

• Imagerotationof0,°180°

• Automatictissueoptimization– single keystroke optimizes immedi-ately automatically and dynamically different grayscale settings with the goal of signal independent uniform gain and contrast distribution

• UDclarityandUDspecklereduceimaging – an advanced image processing technique to remove speckle in real-time examining the relative difference between neigh-boring pixel values and determining whether the grayscale variations have a sharp difference, follow a trend, or are random in nature

• HDimaging–real-timesimultaneous acquisition at dual frequencies compounded to help reduce speckle and noise while enhancing resolution and contrast

• Multiple-anglecompoundimaging– multiple co-planar images from dif-ferent angles combined into a single image in real-time to help enhance border definition and contrast resolution, as well as reduce angular dependence of border or edge as compared to no-compound imaging

• Elevationcompounding (4Dprobesonly)

• LOGIQView:providestheabilitytoconstruct and view a static 2D image with wider field-of-view of a given transducer. This allows viewing and measurements of anatomy that is larger than what would fit in a single image

• Virtualapexprovidesawiderfield-of-view with phased array probes, effective at certain imaging views where a wide near field is preferred

• L/Randup/downinvert,inlive,digitalreplay or image clipboard recall

• Digitalreplayforretrospective review or automatic looping of images, allowing for adjustment of parameters such as gain, reject, anatomical M-mode, persistence and replay speed

Tissue ImagingGeneral

• Variabletransmitfrequenciesforresolution/penetrationoptimization

• Displayzoomwithzoomareacontrol

• High-Resolution(HR)zoom–concen-trates all image acquisition power intoselectedRegionofInterest(ROI)

• Variablecontourfiltering–foredgeenhancement

• Depthrangeupto36cm– probe specific

• Selectablegrayscaleparameters:Gain, reject, DDP, clarity, dynamic range and compress – can be adjusted in live, digital replay and image clipboard recall (probedependent)

• AutomaticallycalculatedTGCcurvesreduces operator interaction

• Automaticallycalculatedlateralgain

2D Mode

• Sectortiltandwidthcontrol

• Framerateinexcessof1000fps,depending on probe, settings and applications

• Codedoctaveimagingwithcodedphaseinversion–3rdgenerationharmonic tissue imaging providing improved lateral and contrast resolu-tion over conventional fundamental imaging. Features help reduce noise, improve wall definition, and axial resolution, making it well suited for a wide variety of patient groups

• Trueconfocalimaging–ultranarrow focused two-way beam profile throughout the field-of-view, main-taining frame rate, no zone stitching, no multi-line acquisition artifacts and enhanced dynamic contrast resolution throughout field-of-view compared to conventional focal imaging

• AdaptiveContrastEnhancement(ACE)–emphasizingechoesfrom real structures while reducing noise/haze,resultinginenhancedsignal-to-noise ratio

Page 7: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June2015–DOC1564269 Page7of19

• Datadependentprocessingperformstemporal processing which helps reduce random noise but leaves motion of significant tissue structures largely unaffected – can be adjusted even in digital replay

• 256shadesofgray

• Colorized2D-mode,user-selectablein real-time, digital replay

• Optimizedpresetsforfurther 2D strain analysis on EchoPAC (separateoption)

4D Mode

• Flexi-volumeswithcustomizable acquisition for volume size, volume rate or resolution

• Single-beat4Dscanningwith real-time volume rendering display

• Multi-beat4Dscanningfor high-resolution scanning

• Adjustablevolumesizesforbothsingle and multi-beat scanning

• Adjustablevolumeshapecontrol

• Pre-definedvolumesizesforquickvolume setup

• Adjustablenumberofcyclesformulti-beat scanning

• FlexiZoomforeasy4Dvisualization of structures of interest

• 4Dscanningsupportingvariableoctave and fundamental frequencies

• HDliveImaging–acquisitionandvisualization providing enhanced display of anatomical structures using advanced shadowing tech-niques in combination with depth illuminating colors (optional )

• 4Dclarity–user-selectableintelligent spatial filtering algorithm for noise reduction and smoothing both in 4D and in extracted 2D slices

• Coherentvolumeprocessingwithmotion compensation for seamless and artifact-free 4D and 2D slices

• Variableframeratesettingsavailable

• Volumeoptimizecontrolfor volume rendering transparency and quality setting

M-mode

• TrackballsteersM-modeline available with all imaging probes – max steering angle is probe dependent

• Simultaneousreal-time 2D- and M-mode

• M-modePRF1kHz–imagedata acquired is combined to give high-quality recording regardless of display scroll speed

• Digitalreplayforretrospectivereviewof spectral data

• Severaltop-bottomformats,side-by-side format and time-motion-only format – can be adjusted in live or digital replay

• Selectablehorizontalscrollspeed: 1,2,3,4,6,8,12,16seconds across display

• Horizontalscrollcanbeadjustedinlive or digital replay

Anatomical M-mode

• M-modecursorcanbeadjusted at any plane

• CurvedanatomicalM-mode– free(curved)drawingofM-modegenerated from the cursor independent from the axial plane

• Canbeactivatedfromlive,digitalreplay or image clipboard recall

• Anatomicalcolorandtissue velocity M-mode

• M&A capability

Color Doppler ImagingGeneral

• SteerablecolorDoppleravailablewith all imaging probes – max steering angle is probe dependent

• Trackball-controlledROI

• Removalofcolormapfromthetissueduring digital replay

• Digitalreplayforretrospective review of color or color M-mode data allowing for adjustment of parameters such as encoding principle, color priority and color gain even on stored data

• Flipcropavailableforchanging4Dviewdirection180degreeswith mirrored crop volume

• Dynamicmulti-sliceenablesposition-ing of the multi-slice, short-axis cut-planes at same anatomical position throughout the heart cycle

• Livemulti-slicelayoutsavailable during live 4D acquisition

• FlexiSliceforinteractiveslicing, cropping and navigation designed to provide the user with a flexible, yet intuitive way of extracting 2D slices from 4D data sets

• View-cropsettingfortogglecontrolof view plane vs. crop plane

• 2-clickcropforquickandeasy extraction of standard and non- standard views for visualization of 4D structures seen during or after the examination

• Stereovisionin4D(option)

• Polarizedstereovisionin4DusedtogetherwithdedicatedSony3Dmonitor (option) may help improve depth perception of 4D image

• Laserlinestohelpimprovethevisuallinkage between the 4D rendered view and the 2D slices

• Widerangeofdepthcolor rendering maps

• QuickRotateandRotateforaflexibleand easily accessible way of obtain-ing the desired single- or multi-plane, two-dimensional views

• 4Dvirtualapexenablingwidernearfield-of-view

Multi-Dimensional Mode

• Bi-planescanning–twoindependentsimultaneous scan planes where one of them can be rotated and tilted freely

• Bi-planepreparemodeforeaseofobtaining biplane views from 4D render data sets

• Tri-plane–threeindependentsimul-taneous scan planes that can be rotated freely

• Bothbi-planeandtri-planescanningis possible in all color Doppler modes

Page 8: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June2015–DOC1564269 Page8of19

• PRFsettings–user-selectable

• Advancedregressionwallfiltergivesefficient suppression of wall clutter

• Foreachencodingprinciple,multiplecolor maps can be selected in live and digital replay – variance maps available

• Morethan65,000simultaneouscolors processed, providing a smooth display two-dimensional color maps containing a multitude of color hues

• Simultaneousdisplayofgrayscale 2D and 2D with color flow

• Colorinvert–user-selectableinliveand digital replay

• Variablecolorbaseline– user-selectable in live and digital replay

• Multi-variatecolorpriorityfunctiongives delineation of disturbed flows even across bright areas of the 2D-mode image

• ColorDopplerfrequencycanbechanged independently from 2D

Color Flow Imaging

• ThecSoundplatformwithitsparallel beamformer architecture allows a combination of ultra-high frame rate and increased lateral resolution compared to previous generation GE scanners

• Ultra-highdigitalsignalprocessingpower, maintaining high frame rates withlargeROI'sevenforverylow PRFsettings

• Framerateinexcessof150fps, depending on probe and settings

• VariableROIsizeinwidthanddepth

• User-selectableradialandlateralaveraging to help reduce statistical uncertainty in the color velocity and variance estimates

• DataDependentProcessing(DDP)performs temporal processing and display smoothing to help reduce loss of transient events of hemo-dynamic significance

Color M-mode

• VariableROIlengthandposition– user-selectable

• User-selectableradialaveragingtohelp reduce statistical uncertainty in the color velocity and variance estimates

• Selectablehorizontalscrollspeed: 1,2,3,4,6,8,12,16seconds across display – can be adjusted during live, digital replay or image clipboard recall

• Real-time2Dimagewhilein color M-mode

• Samecontrolsandfunctionsavailable as in standard 2D color Doppler

Anatomical Color M-mode• GE-patented,anyplanecolor

M-mode display derived from color Doppler cine loop

• Alsoapplicabletotissue velocity Imaging

• M&A capability

B-flow

• B-flowisadigitalimagingtechniquethat provides real-time visualization of vascular hemodynamics by directly visualizing blood reflectors and presenting this information in a grayscale display

• UseofGE-patentedtechniquestoboost blood echoes, and to help preferentially suppress non-moving tissue signals

• B-flowisavailableformostvascularand shared service applications

Blood Flow Imaging

• CombinescolorDopplerwith grayscale speckle imaging

• Helpsimprovedelineationofbloodflow without bleeding into tissue or vessel wall

Blood Flow Angio Imaging

• Combinesangiowithgrayscalespeckle imaging

• Digitalreplayforretrospective review or automatic looping of color images, allowing for adjustment of parameters such as DDP, encoding principle, baseline shift, color maps, color priority and color gain even on frozen/recalleddata

• Application-dependent,multi-variatemotion discriminator helps reduce flash artifacts

• Dedicatedcoronaryflowapplication

• Multiple-anglecompoundimagingin2D mode is maintained while in color Doppler mode

4D Color Doppler Imaging

• Single-beat4Dcolorflowscanning

• VolumesizecontroltochangethesizeofthecolorROI

• Multi-beat4Dcolorflowscanningusing ECG stitching for increased volume rate

• Pre-definedvolumesizesforquickvolume setup

• Adjustablenumberofcyclesformulti-beat scanning

• Variablevolumeratesettingsavailable

• Flipcropavailableforchanging 4Dviewdirection180degrees with mirrored crop volume

• View-cropsettingfortogglecontrolof view plane vs. crop plane

• Stereovisionin4Dcolor

• Tissuetransparencycontrol

• Flowtransparencycontrol

Multi-Dimensional Color Mode

• Bi-planeandtri-planescanning with all color Doppler and tissue velocity modes

Color Angio

• Angle-independentmodefor visualization of small vessels with increased sensitivity compared to standard color flow of previous GE products

Page 9: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 9 of 19

Tissue Velocity ImagingTissue Velocity Imaging Mode

• MyocardialDopplerimagingwithcolor overlay on tissue image

• TissueDopplerdatacanbeacquired in background during regular 2D imaging

• Thevelocityofmyocardialsegmentsafter entire heart cycle can be displayed in one single image

• Tissuecoloroverlaycanberemovedto show just the 2D image, still retain-ing the tissue velocity information

• QuantitativeprofilesforTVI,tissuetracking, strain and strain rate can be derived

• Timemarkersforvalveeventsderived from any TM mode help simplify understanding of signals in velocity traces or curved anatomical M-mode

Tissue Tracking Mode

• Real-timedisplayofthetimeintegral of TVI for quantitative display of myocardial systolic displacement

• Myocardialdisplacementiscalculated and displayed as a color-coded overlay on the grayscale and M-mode image – different colors represent different displacement ranges

Tissue Synchronization Imaging Mode (option, enabled by Advanced QScan)

• Parametricimagingwhichgivesinformation about synchronicity of myocardial motion

• Myocardialsegmentscolored according to time to peak velocity, green for early and red for late peak

• Waveformtraceavailableto obtain quantitative time to peak measurement from TSI Image

• Availableinlivescanning,aswellasan offline calculation derived from tissue Doppler data

• Additionalfeaturesincombinationwith multi-dimensional imaging option

• Simultaneousacquisitionoftri-planeTSI images covering all standard in apical views

• Dynamicrejectgivesconsistent suppression of background – user-selectable in real-time, digital replay or image clipboard recall

• Digitalreplayforretrospective review of spectral Doppler data

• Severaltop-bottomformats, side-by-side format and time- motion-only format – can be adjusted in live or digital replay

• Selectablehorizontalscrollspeed:1,2,3,4,6,8,12,16secondsacrossdisplay – can be adjusted in live or digital replay

• AdjustablespectralDopplerdisplayparameters:Gain,reject,compress,color maps – can be adjusted in live or digital replay

• User-adjustablebaselineshift– in live, digital replay and image clipboard recall

• Adjustablevelocityscale

• Wallfilterswithrange10-2000Hz(velocityscaledependent)

• Anglecorrectionwithautomaticadjustment of velocity scale – in live, digital replay and image clipboard recall

• AutoDopplerangle

• Stereospeakersmountedinthe front panel

• Displayannotationsoffrequency,mode,scales,Nyquistlimit,wallfiltersetting, angle correction, acoustic power indices

• Compoundinduplex

PW/HPRF Doppler

• AutomaticHPRFDopplermaintainsits sensitivity even for shallow depths andwiththehighestPRF's

• DigitalvelocitytrackingDoppler employs processing in range and time for high-quality spectral displays

• Adjustablesamplevolumesizeof1-16mm(probedependent)

• Maximumsamplevolumedepth30cm

• EfficientsegmentspecificTSItimemeasurements

• Immediatebulls-eyereport

• AutomaticcalculatedTSI synchrony indexes

• TSIsurfacemapping

• LVsynchronizationreporttemplate

• CRTprogrammingprotocol

Strain/Strain Rate Mode (option, enabled by Advanced QScan)

• Tissuedeformation(strain)andrateofdeformation(strainrate)arecal-culated and displayed as real-time, color-coded overlay on the 2D image

• Cinecompoundcalculatesanddisplays cineloops generated from a temporal averaging of multiple consecutive heart cycles

• AnatomicalM-modeandcurved anatomical M-mode displays (SIandSRI)

Spectral DopplerGeneral

• OperatesinPW,HPRFandCWmodes

• TrackballsteerableDoppleravailablewith all imaging probes – max steering angle is probe dependent

• SelectableDopplerfrequencyforenhanced optimization

• High-quality,real-timeduplexor triplex operation in all Doppler modes,CWandPW,andfor all velocity settings

• Frameratecontrolforoptimized use of acquisition power between spectrum, 2D and color Doppler modes in duplex or triplex modes

• Veryfastandflexiblespectrumanalysis with an equivalent DFT rate of 0.2 ms

• AutomaticSpectrumOptimization(ASO)providesasinglepush,auto-matic, real-time optimization of PWorCWspectrumscaleand baseline display

• Dynamicgaincompensationfordisplay of flows with varying signal strengths over the cardiac cycle to help improve ease of use

Page 10: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 10 of 19

CW Doppler

• HighlysensitivesteerableCWavailable with all phased array probes

• TissuevelocityDoppler

Contrast ImagingLVO Contrast (standard)• Enablescontrastapplicationsintended

for imaging of the left ventricle

• LVcontrast(4V-D,M5Sc-D,6VT-D) enhancesdelineationoftheLVborder in combination with ultrasound contrast agents. The implementation ofGE'sCodedPhaseInversion(CPI)provides high-resolution detection ofcontrastintheLVcavityandexcellent suppression of myocardial tissue signals. Furthermore, tri-plane imagingwith4V-DusingLVcontrastenables acquisition of three simul-taneous apical views within one cardiac cycle

• LVOstress(M5Sc-D)provides enhanceddelineationoftheLV border when contrast is used as part of an exercise stress exam, preserving an adequately long continuous capture buffer length

Contrast Low MI (option) 1, 2

ContrastLowMIimagingenabled by the Advanced Contrast option.

• Withimprovedresolution,tissuesuppression and higher contrast sensitivity, obtained by utilizing the new Coded Phase Inversion mode (B-mode)intendedforlowpowerreal-time myocardial contrast imaging. Destruction wash-in studies are possibleonlineorofflineusing“flash”andQ-analysisfeatures.OfflineECGtriggering(acquirethefullcineloop) is yet another useful tool of the ContrastLowMIapplication

• Parameterannotationfollow ASE standard

• Seamlessdatastorageand report creation

• User-assignableparameters

• Comprehensive set of cardiac measurements and calculations to help assess dimensions, flow properties and other functional parameters of the heart

• Comprehensive set of shared service measurements and calculations cov-ering vascular, abdominal, obstetrics and other application areas

• Configurationpackagetosetup a customized set and sequence of measurements to use, defining user-defined measurements and changing settings for the factory-defined measurements

• Stressechosupportallowingwallmotion scoring and automatic stress level labeling of measurements

• SupportformeasuringonDVR recordings and DICOM images

• AutomaticDopplertracefunctionality for use in non-cardiac applications in both live and replay

• Worksheetforreview,editand deletion of performed measurements

• Reportingsupportallowinga configurable set of measurements to be shown in the exam report

• DICOMSRexportofmeasurementdata

Intima Media Thickness (IMT) Measurements (optional )

• Automaticmeasurements (patentpending)ofcarotidarteryIntima-MediaThickness(IMT)on any acquired frame

• On-boardIMTpackagefacilitatesnon-interrupted workflow – fully integrated with M&A, worksheet, archiving and reporting functions

• Algorithmprovidesrobust,quick, reliable measurements which can be stored to the on-board archive for review and reporting

Vascular/Abdominal Contrast (option) 1, 2

Vascular Contrast – enables contrast applicationsintendedforvascular(9L-D)andabdominal(C1-5)contrastimaging.

• VascularContrast(9L-D)–codedphase inversion enables excellent detection and resolution of vascular contrast imaging

Physiological Traces• Integratedthree-leadECGmodule

• AutomaticQRScomplexdetection

• ExternalECGleadinput

• Uptothreetracesdisplay simultaneously

• Internallygeneratedrespiratory trace using ECG leads

• ECGtrigger

• ECGleadselection

• High-resolutiondisplayofthe followingtraces:ECG,respiration,phono,andpressure/AUX

• AdjustableECGQRSmarkers

Automatic Optimization• DynamicoptimizationofB-mode

image to improve contrast resolution, TGC and grayscale (soft or sharp, user-selectable)

• Auto-spectraloptimize–dynamicadjustmentsofbaseline,andPRF (onliveimage)andanglecorrection

Measurement and Analysis (M&A)• Personalized measurement protocols

allow individual set and order of M&A items

• Measurementscanbelabeled seamlessly by using protocols or post assignments

• Measurementsassignableto protocol capability

1 Schering developed harmonic imaging for supporting contrast agent imaging.

2 GE Healthcare's Vivid scanner is designed for compatibility with commercially available contrast agents. Because the availability of these agents is subject to government regulation and approval, product features intended for use with these agents may not be commercially marketed nor made available before the contrast agent is approved for use. Advanced contrast features are only enabled on systems for delivery in countries or regions where the agents are approved for use or for investigational or research use.

Page 11: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 11 of 19

• IMTmeasurementcanbemadefromfrozen images or images retrieved from archive

• IMTpackagesupportsmeasure-ments of different regions of the intima in the carotid vessel (e.g.,Lt./Rt./CCA/ICAetc.)

• FrameforIMTmeasurement can be selected in relation to the ECG waveform

Z-Scores

• Limitedimplementationofz-scoresfor a set of predefined pediatric dimension measurements

4D Auto LVQ

• AutomatedmeasurementofLVvolume and EF from volumetric data

• AutomatedidentificationofLV long-axis and standard views

• Automatedinitializationof measurementROI

• Validationofdetectedboundaries

• LVvolumewaveformforentire cardiac cycle

• EDandESautomaticallyselectedfromvolumewaveform(max/min)

• Editingbypointandclick

• Userapprovaloffinalresults

• FullyintegratedintoM&A system with results in worksheet

4D LV Mass (optional ) and 4D Strain (optional )

• LVMasswithSphericityIndex(SI)

• 4DStrainwithsupportforthefollow-ingparameters:Area,longitudinal,circumferential, radial, twist and torsion.Allglobaland/orsegmental

• Retrospectiveeditingavailablein 4D Strain

• Strainbulls-eyesandgraphssup-portedinadditiontoLVsurfacemodel with strain color overlay

• 4DStrainexportavailablein HDFformat

• Userapprovaloffinalresults

Automated Function Imaging (AFI) (optional )

• Parametricimagingtoolwhich gives quantitative data for global and segmental wall motion

• Allowscomprehensiveassessment at a glance by combining three longitudinal views into one compre-hensive bulls-eye view

• IntegratedintoM&A package with specialized report templates

• 2Dstrainbaseddatamovesintoclinical practice

• Simplifiedworkflowwithfully automatedROItracing(ifconfigured),quick tips and combined display of traces from all segments

• PeakStrainDispersion(PSD) ( included in AFI and 2D Strain [EchoPAC] ).Index,aswellas bulls-eye displaying variability in time to peak longitudinal strain. The index is the standard deviation fromtheaverage(ofallsegments)over the whole heart cycle, while the bulls-eye displays the PSD in a color scheme where green color indicates normal contraction with a peak at or around AVC, blue color indicates early contraction and yellow to red indicates late contraction

AFI Stress (optional )

• Dedicatedprotocolandworkflow integrating AFI as part of a stress exam (pharmacological, as well as exercise)–seeStressEchosection

Automated Ejection-Fraction Calculation (AutoEF) (optional )

• AutomatedEFmeasurementtoolbased on 2D-speckle tracking algorithm and on Simpson

• IntegratedintoM&A package with worksheet summary

Generic Measurements

• BSA(BodySurfaceArea)

• MaxPG(MaximumPressureGradient)

• MeanPG(MeanPressureGradient)

• %Stenosis(StenosisRatio)

• PI(PulsatilityIndex)

• FullyintegratedintoM&A system with results in worksheet

4D Auto AVQ (optional )

• Automatedalignment,segmentationand measurement of aortic annulus from volumetric data sets

• Editingbypointandclick

• Userapprovaloffinalresults

• FullyintegratedinM&A system with results in worksheet

Mitral Valve Assessment (optional )

• Thesemi-automatedMVassessmenttool from Tomtec provides the ability to include quantitative results for the mitral valve apparatus, into the patient exam

4D RV Volume (optional )

• Thesecondgeneration4DRight Ventricle(RV)volumetoolfrom Tomtec provides volumes, ejection fraction,TAPSEandRVstrain values from volumetric data sets

• Theanalysistoolprovidesthe ability to include results (both alpha-numeric values and screen captures)intothepatientexam

Quantitative Analysis Package (Q-Analysis)

• Tracesforvelocityorderived parameters (strain rate, strain, displacement)insidedefinedregions of interest as function of time

• Contrastanalysiswithtracesforgrayscale intensity or angio power inside defined regions of interest as function of time, including post processing ECG trigging and curve fittingforwashin/washoutanalysis

• CurvedanatomicalM-modedisplayallowing an M-mode along an arbitrary curve in a 2D image

• Sample-areapointsmaybedynami-cally anchored to move with the tissue when running the cineloop

• Cinecompounddisplayscineloopsgenerated from a temporal averaging of multiple consecutive heart cycles

Page 12: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 12 of 19

• RI(ResistivityIndex)

• HR(HeartRate)–beats/minute

• A/BRatio(VelocitiesRatio)

• TAMAX(TimeAveragedMaximumVelocity)–TracemethodisPeak or Manual

• TAMIN(TimeAveragedMinimumVelocity)–TracemethodisFloor

• TAMEAN(TimeAveragedMean Velocity)–TracemethodisMean

• Volume

OB/GYN Application Module• OBpackageforfetalgrowth

analysis containing more than 100 biometry tables

• DedicatedOB/GYNreports

• Fetalgraphicalgrowthcharts

• Growthpercentiles

• Multi-gestationalcalculations (uptofour)

• ProgrammableOBtables

• Expandedworksheets

• User-selectablefetalgrowthparam-eters based on European, American or Asian methods charts

• GYNpackageforovaryanduterusmeasurements and reporting

OB Measurements/Calculations

• Gestationalageby :

- GS(GestationalSac)

- CRL(CrownRumpLength)

- FL(FemurLength)

- BPD(BiparietalDiameter)

- AC(AbdominalCircumference)

- HC(HeadCircumference)

- APTDxTTD(Anterior/PosteriorTrunk Diameter by Transverse TrunkDiameter)

- LV(LengthofVertebra)

- FTA (FetalTrunkCross-sectionalArea)

- HL(HumerusLength)

- BD(BinocularDistance)

- FT(FootLength)

- OFD(OccipitalFrontalDiameter)

• Ovarianvolume

• ENDO(endometrialthickness)

• OvarianRI

• UterineRI

• Follicularmeasurements

• Summaryreports

Vascular Calculations• RTECA(RightExternalCarotid ArteryVelocity)

• RTCCA(RightCommonCarotid ArteryVelocity)

• RTBIFURC(RightCarotid BifurcationVelocity)

• RTICA(RightInternalCarotid ArteryVelocity)

• RTICA/CCA(RightInternalCarotid ArteryVelocity/CommonCarotidArteryVelocityRatio)

• LTECA,LTCCA,LTBIFURC,LTICA, LTICA/CCA(sameasabove,forLeftCarotidArtery)

• A/BRatio(VelocitiesRatio)

• %Stenosis(StenosisRatio)

• S/DRatio(SystolicVelocity/DiastolicVelocitiesRatio)

• PI(PulsatilityIndex)

• RI(ResistivityIndex)

• HR(HeartRate)–beats/minute

Cardiac Measurements• %FS(LVFractionalShortening)

• %IVSThck(IVSFractionalShortening)

• %LVPWThck(LVPosteriorWall FractionalShortening)

• AoArchDiam(AorticArchDiameter)

• Aoasc(AscendingAorticDiameter)

• AoDescDiam (DescendingAorticDiameter)

• AoIsthmus(AorticIsthmus)

• AoRootDiam(AorticRootDiameter)

• ARERO (PISA:RegurgitantOrificeArea)

• ARFlow(PISA:RegurgitantFlow)

• ARPHT(AVInsuf.PressureHalfTime)

- TAD (TransverseAbdominalDiameter)

- TCD (TransverseCerebellumDiameter)

- THD(ThoraxTransverseDiameter)

- TIB(TibiaLength)

- ULNA(UlnaLength)

• EstimatedFetalWeight(EFW)by:

- AC,BPD

- AC,BPD,FL

- AC,BPD,FL,HC

- AC,FL

- AC,FL,HC

- AC,HC

- EFBW

• CalculationsandRatios

- FL/BPD

- FL/AC

- FL/HC

- HC/AC

- CI(CephalicIndex)

- AFI(AmnioticFluidIndex)

- CTAR(Cardio-ThoracicAreaRatio)

• Measurements/calculationsby:ASUM,ASUM2001,Berkowitz,Bertagnoli,Brenner,Campbell,CFEF,Chitty,Eik-Nes,Ericksen,Goldstein,Hadlock,Hansmann,Hellman,Hill,Hohler,Jeanty,JSUM,Kurtz,Mayden,Mercer,Merz,Moore,Nelson,OsakaUniversity,Paris,Rempen,Robinson,Shepard,Shepard/Warsoff,TokyoUniversity,Tokyo/Shinozuka,Yarkoni

• Fetalgraphicaltrending

• Growthpercentiles

• Multi-gestationalcalculations(4)

• Fetalqualitativedescription (anatomicalsurvey)

• Fetalenvironmentaldescription (biophysicalprofile)

• ProgrammableOBtables

• Over20selectableOBcalculations

• Expandedworksheets

GYN Measurements/Calculations

• Rightovarylength,width,height

• Leftovarylength,width,height

• Uteruslength,width,height

• Cervixlength,trace

Page 13: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June2015–DOC1564269 Page13of19

• ARRad(PISA:RadiusofAliasedPoint)

• ARRF(RegurgitantFractionovertheAorticValve)

• ARRV (PISA:RegurgitantVolumeFlow)

• ARVel(PISA:AliasedVelocity)

• ARVmax(AorticInsuf.PeakVelocity)

• ARVTI (AorticInsuf.VelocityTimeIntegral)

• ARedmaxPG(AorticInsuf. End-DiastolePressureGradient)

• ARedVmax(AorticInsuf. End-DiastolicVelocity)

• AVAccSlope (AorticValveFlowAcceleration)

• AVAccTime (AorticValveAccelerationTime)

• AVAccT/ET(AVAccelerationto EjectionTimeRatio)

• AVEOAI(VTI)(AorticValve Effective Orifice Area Index byContinuityEquationVTI)

• AVEOAIVmax(AorticValve Effective Orifice Area Index byContinuityEquationPeakV)

• AVCO(CardiacOutputbyAorticFlow)

• AVCusp (AorticValveCuspSeparation,2D)

• AVDecTime (AorticValveDecelerationTime)

• AVDiam(AorticDiameter,2D)

• AVmaxPG(AorticValvePeak PressureGradient)

• AVMeanPG(AorticValveMean PressureGradient)

• AVSV(StrokeVolumebyAorticFlow)

• AVVmax(AorticValvePeakVelocity)

• AVVmean(AVMeanVelocity)

• AVVTI (AorticValveVelocityTimeIntegral)

• AVA(Vmax)(AVAreabyContinuityEquationbyPeakV)

• AVA(VTI)(AVAreabyContinuity EquationVTI)

• AVAPlanimetry(AorticValveArea)

• AVET(AorticValveEjectionTime)

• LVAd(A2C)(LeftVentricularArea,Diastolic,2CH)

• LVAd(sax)(LVarea,SAX,Diastolic)

• LVAend(d)(LVEndocardialArea,SAX)

• LVAepi(d)(LVEpicardialArea,SAX)

• LVAs(A4C)(LeftVentricularArea,Systolic,4CH)

• LVAs(sax)(LVarea,SAX,Systolic)

• LVdMass(LVMass,Diastolic,2D)

• LVdMass (LVMass,Diastolic,M-mode)

• LVdMassIndex (LVMassIndex,Diastolic,2D)

• LVEDV(A-LA2C)(LVVolume,Diastolic,2CH,Area-Length)

• LVESV(A-LA2C)(LVVolume,Systolic,2CH,Area-Length)

• LVET(LeftVentricleEjectionTime)

• LVIDd(LVInternalDimension, Diastolic,2D)

• LVIDs(LVInternalDimension, Systolic,2D)

• LVLd(apical)(LeftVentricularLength,Diastolic,2D)

• LVLs(apical)(LeftVentricularLength,Systolic,2D)

• LVOTArea(LeftVentricleOutflowTractArea)

• LVOTCO (CardiacOutputbyAorticFlow)

• LVOTDiam(LeftVentricularOutflowTractDiameter)

• LVOTmaxPG (LVOTPeakPressureGradient)

• LVOTMeanPG (LVOTMeanPressureGradient)

• LVOTSI(StrokeVolumeIndex byAorticFlow)

• LVOTSV (StrokeVolumebyAorticFlow)

• LVOTVmax(LVOTPeakVelocity)

• LVOTVmean(LVOTMeanVelocity)

• LVOTVTI(LVOTVelocityTimeIntegral)

• LVPWd(LeftVentricularPosteriorWallThickness,Diastolic,2D)

• CO(Teich)(CardiacOutput, M-mode,Teicholtz)

• D-EExcursion (MVAnteriorLeafletExcursion)

• EDV(Cube)(LeftVentricleVolume,Diastolic,2D,Cubic)

• EF(A-LA2C)(EjectionFraction2CH,SinglePlane,Area-Length)

• E-FSlope(MitralValveE-FSlope)

• EPSS(E-Point-to-SeptumSeparation,M-mode)

• ERO(EffectiveRegurgitantOrifice)

• ESV(Cube)(LeftVentricleVolume,Systolic,2D,Cubic)

• HR(HeartRate,2D,Teicholtz)

• IVC(InferiorVenaCava)

• IVCT(IsovolumicContractionTime)

• IVRT(IsovolumicRelaxationTime)

• IVSd(InterventricularSeptum Thickness,Diastolic,2D)

• VSs(InterventricularSeptum Thickness,Systolic,2D)

• LADiam(LeftAtriumDiameter,2D)

• LAMajor(LeftAtriumMajor)

• LAMinor(LeftAtriumMinor)

• LA/Ao(LADiametertoAoRoot DiameterRatio,2D)

• LAAd(A2C) (LeftAtriumArea,Apical2C)

• LAEDV(A-L)(LAEndDiastolicVolume,Area-Length)

• LAEDVIndex(A-L)(LAEndDiastolicVolumeIndex,Area-Length)

• LAESV(A-L)(LAEndSystolicVolume,Area-Length)

• LAESVIndex(A-L)(LAEndSystolicVolumeIndex,Area-Length)

• LAEDVMOD (LAEndDiastolicVolumeMOD)

• LAESVMOD (LAEndSystolicVolumeMOD)

• LIMP(LeftIndexofMyocardial Performance)

• LVA(s)(LeftVentricularArea, Systolic,2CH)

Page 14: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 14 of 19

• LVPWs(LeftVentricularPosteriorWallThickness,Systolic,2D)

• LVsMass(LVMass,Systolic,2D)

• LVsMassIndex(LVMassIndex, Systolic,2D)

• LAAd(A2C) (LeftAtriumArea,Apical2C)

• MCO(MitralValveclosuretoOpening)

• MPArea(MitralValveProsthesis)

• MRAccTime (MVRegurg.FlowAcceleration)

• MRERO (PISA:RegurgitantOrificeArea)

• MRFlow(PISA:RegurgitantFlow)

• MRmaxPG(MitralRegurg. PeakPressureGradient)

• MRRad(PISA:RadiusofAliasedPoint)

• MRRF(RegurgitantfractionovertheMitralValve)

• MRRV (PISA:RegurgitantVolumeFlow)

• MRVel(PISA:AliasedVelocity)

• MRVmax (MitralRegurg.PeakVelocity)

• MRVmean (MitralRegurg.MeanVelocity)

• MRVTI(MitralRegurg. VelocityTimeIntegral)

• MVADur (MitralValveA-WaveDuration)

• MVAVelocity(MVVelocityPeakA)

• MVAccSlope (MitralValveFlowAcceleration)

• MVAccTime (MitralValveAccelerationTime)

• MVAcc/DecTime (MV:Acc.Time/Decel.TimeRatio)

• MVandiam(MitralValveAnnulusDiameter,2D)

• MVCO (CardiacOutputbyMitralFlow)

• MVDecSlope (MitralValveFlowDeceleration)

• MVDecTime (MitralValveDecelerationTime)

• MVEVelocity(MVVelocityPeakE)

• PRendmaxPG(PulmonicInsuf. End-DiastolePressureGradient)

• PRendVmax(PulmonicInsuf. End-DiastolicVelocity)

• PulmonicDiam (PulmonaryArteryDiameter,2D)

• PVAccSlope (PulmonicValveFlowAcceleration)

• PVAccTime (PulmonicValveAccelerationTime)

• PVAccTime/ETRatio(PVAcceleration toEjectionTimeRatio)

• PVandiam(PulmonicValveAnnulusDiameter,2D)

• PVAnnArea(PulmonicValveArea)

• PVCO (CardiacOutputbyPulmonicFlow)

• PVmaxPG(PulmonicValvePeakPressureGradient)

• PVMeanPG(PulmonicValveMeanPressureGradient)

• PVSV (StrokeVolumebyPulmonicFlow)

• PVVmax (PulmonaryArteryPeakVelocity)

• PVVmean(PVMeanVelocity)

• PVVTI(PulmonicValveVelocity TimeIntegral)

• PVA(VTI)(PulmonaryArteryVelocityTimeIntegral)

• PVeinS/DRatio (PulmonaryVeinSDRatio)

• PVET(PulmonicValveEjectionTime)

• PVPEP (PulmonicValvePre-EjectionPeriod)

• PVPEP/ETRatio(PVPre-EjectiontoEjectionTimeRatio)

• Qp/Qs (Pulmonic-to-SystemicFlowRatio)

• RAMajor(RightAtriumMajor,2D)

• RAMinor(RightAtriumMinor,2D)

• RAA(d) (RightAtriumArea,2D,Diastole)

• RAA(s)(RightAtriumArea,2D,Systole)

• RAEDVA2C(RightAtriumEnd DiastolicVolume,Apical2Chamber)

• MVE/ARatio(MitralValveE-Peak toA-PeakRatio)

• MVmaxPG(MitralValvePeak PressureGradient)

• MVMeanPG(MitralValveMean PressureGradient)

• MVPHT (MitralValvePressureHalfTime)

• MVRegFrac (MitralValveRegurgitantFraction)

• MVSI (StrokeVolumeIndexbyMitralFlow)

• MVSV(StrokeVolumebyMitralFlow)

• MVTimetoPeak (MitralValveTimetoPeak)

• MVVmax(MitralValvePeakVelocity)

• MVVmean(MVMeanVelocity)

• MVVTI (MitralValveVelocityTimeIntegral)

• MVA(MitralValveArea)

• MVAByPHT(MitralValveArea AccordingtoPHT)

• MVAbyplan(MitralValveArea,2D)

• MVET(MitralValveEjectionTime)

• PVeinA(PulmonaryVeinVelocityPeakA)–reverse

• PVeinADur (PulmonaryVeinA-WaveDuration)

• PVeinD(PulmonaryVein End-DiastolicPeakVelocity)

• PVeinS(PulmonaryVeinSystolicPeakVelocity)

• PAEDP(PulmonaryArtery DiastolicPressure)

• PE(d)(PericardEffusion,M-mode)

• PEs(PericardEffusion,2D)

• PRmaxPG(PulmonicInsuf.PeakPressureGradient)

• PRMeanPG(PulmonicInsuf.MeanPressureGradient)

• PRPHT (PulmonicInsuf.PressureHalfTime)

• PRVmax (PulmonicInsuf.PeakVelocity)

• PRVTI(PulmonicInsuf.Velocity TimeIntegral)

Page 15: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 15 of 19

• RAESVA-L (RAEndSystoleVolume[A-L] )

• RALd(RightAtriumLength,Diastole)

• RALs(RALength,Systole)

• RIMP(RightIndexof MyocardialPerformance)

• RJA(A4C)(RegurgitantJetArea)

• RJA/LAA (RegurgitantJetArearatioRJA/LAA)

• RVMajor(RightVentricleMajor)

• RVMinor(RightVentricleMinor)

• RVAWd(RightVentricleWall Thickness,Diastolic,2D)

• RVAWs(RightVentricleWall Thickness,Systolic,2D)

• RVET(RightVentricleEjectionTime)

• RVIDd(RightVentricleDiameter, Diastolic,2D)

• RVIDs(RightVentricleDiameter, Systolic,2D)

• RVOTArea(RightVentricleOutflowTractArea)

• RVOTDiam(RVOutputTract Diameter,2D)

• RVOTDiam(RVOutputTract Diameter,M-Mode)

• RVOTmaxPG (RVOTPeakPressureGradient)

• RVOTMeanPG (RVOTMeanPressureGradient)

• RVOTSI(LVStrokeVolumeIndex byPulmonicFlow)

• RVOTSV (StrokeVolumebyPulmonicFlow)

• RVOTVmax(RVOTPeakVelocity)

• RVOTVmean(RVOTMeanVelocity)

• RVOTVTI (RVOTVelocityTimeIntegral)

• RVSP (RightVentricleSystolicPressure)

• RVWd(RightVentricleWallThickness,Diastolic,M-mode)

• RVWs(RightVentricleWallThickness,Systolic,M-mode)

• RAA(d) (RightAtriumArea,2D,Diastole)

• TRVmax(TricuspidRegurg. PeakVelocity)

• TRVmean(TricuspidRegurg. MeanVelocity)

• TRVTI(TricuspidRegurgitation VelocityTimeIntegral)

• TVAdur (TricuspidValveA-WaveDuration)

• TVAVelocity (TricuspidValveAVelocity)

• TVAccTime (TricuspidValveTimetoPeak)

• TVAnnArea(TricuspidValveArea)

• TVAnnDiam(TricuspidValve AnnulusDiameter,2D)

• TVArea(TricuspidValveArea,2D)

• TVCO (CardiacOutputbyTricuspidFlow)

• TVDecSlope(TricuspidValveFlowDeceleration)

• TVEVelocity (TricuspidValveEVelocity)

• TVE/ARatio(TricuspidValveE-PeaktoA-PeakRatio)

• TVmaxPG(TricuspidValvePeakPressureGradient)

• TVMeanPG(TricuspidValveMeanPressureGradient)

• TVPHT (TricuspidValvePressureHalfTime)

• TVSV (StrokeVolumebyTricuspidFlow)

• TVVmean(TVMeanVelocity)

• TVVTI(TricuspidValveVelocity TimeIntegral)

• VSDmaxPG (VSDPeakPressureGradient)

• VSDVmax(VSDPeakVelocity)

PleaserefertotheReferenceManualfor the full list of measurements and calculations for all applications.

AnnotationsBody Marks

• Bodymarkiconsforlocationandposition of probe

• Easyselectionofbodymarksfromtouch panel

• RAA(s)(RightAtriumArea,2D,Systole)

• SI(A-LA2C)(LVStrokeIndex,SinglePlane,2CH,Area-Length)

• SI(A-LA4C)(LVStrokeIndex, SinglePlane,4CH,Area-Length)

• SI(Bi-plane) (LVStrokeIndex,Bi-Plane,MOD)

• SI(bullet) (LVStrokeIndex,Bi-Plane,Bullet)

• SI(MODA2C)(LVStrokeIndex, SinglePlane,2CH,MOD)

• SI(MODA4C)(LVStrokeIndex, SinglePlane,4CH,MOD)

• SI(Teich) (LVStrokeIndex,Teicholtz,2D)

• SI(Teich)(LVStrokeIndex,Teicholtz,M-mode)

• SV(A-LA2C)(LVStrokeVolume, SinglePlane,2CH,Area-Length)

• SV(A-LA4C)(LVStrokeVolume, SinglePlane,4CH,Area-Length)

• SV(Bi-plane)(LVStrokeVolume, Bi-plane,MOD)

• SV(bullet)(LVStrokeVolume, Bi-plane,Bullet)

• SV(MODA2C)(LVStrokeVolume,Single-plane,2CH,MOD)–Simpson

• SV(MODA4C)(LVStrokeVolume,Single-plane,4CH,MOD)–Simpson

• SV(Cube) (LVStrokeVolume,2D,Cubic)

• SV(Cube) (LVStrokeVolume,M-mode,Cubic)

• SV(Teich) (LVStrokeVolume,2D,Teicholtz)

• SV(Teich) (LVStrokeVolume,M-mode,Teicholtz)

• SystemicDiam (SystemicVeinDiameter,2D)

• SystemicVmax (SystemicVeinPeakVelocity)

• SystemicVTI (SystemicVeinVelocityTimeIntegral)

• TCO (TricuspidValveClosuretoOpening)

• TRmaxPG(TricuspidRegurg. PeakPressureGradient)

• TRMeanPG(TricuspidRegurg. MeanPressureGradient)

Page 16: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June 2015 – DOC1564269 Page 16 of 19

Text Annotations

• Easyselectionoftextannotationsfrom touch panel

Scan Assist Pro• Customizableautomationsthat

assist the user through each step of the scan

• Helpsenhanceconsistencyandreduce keystrokes

• Supportsselectionofallmodes,allmeasurements and dual annotations

• Imagingattributes:Octave,Steer,Dual/Quadscreen,Compound,LogiqView,Zoom,Depth,Scale andBaseline

• On-lineoroff-lineprotocoleditor

• Imageacquisitionaccordingto predefined protocol templates

• Variousfactoryprotocoltemplates

• User-configurableprotocoltemplates

Stress Echo (optional)

Supported Protocol Examinations

• 2Dpharmacologicalstressecho

• 2Dbicyclestressecho

• 2Dcontinuouscapturestressecho(treadmillstressecho)

• AFIStressprotocols (separateoption) – acquire standard apical 2D views and quantify wall motion (longitudinal segmentalandglobalstrain)atallstress levels (Note: AFI and Stress options required separately .)

• Multi-planestressecho

• 4Dstressecho

• Combined4D/multi-planeand continuous capture stress echo

• Cardiacresynchronizationtherapyprogramming protocols (availablewiththeAdvancedQScanoption)

Protocol Examinations Features(enabled with stress option)

• Wallmotionscoring:Analysis by wall motion in individual myocardial segments

• Showreference:Showareferenceimage from baseline or previous level during acquisition

4D Stress Echo

• 4Dvolumeacquisition

• Simultaneousdisplayofthree apical and one short-axis projection during acquisition

• 4Dvolumeimagesanalyzedin long-axis or short-axis projections

• Long-axisanalysisallowrotating the plane around the main axis

• Short-axisanalysisallowtranslationof the plane along the main axis

Wall Motion Scoring

• Aspartofthemeasurementandanalysis package one can access a wall motion assessment module, providinganalysis/scoringof individual myocardial segments

• Forusewithallstressmodalities

Cardiac Resynchronization Therapy (CRT) Programming Protocols• CRTprotocolsrequireStressand AdvancedQScan

• Tailoredacquisitionprotocolfordataneeded for programming of AV and VV delays in biventricular pacemakers

• Imageacquisitionofasetofprojection views with various scan mode settings

• Templateeditor

• User-configurableprotocoltemplates

• Configureprotocolname,number of levels and views, name of level and views and several other protocol settings (smart stress, show reference, scan mode, preview of store, timer handling,etc.)

4D Analysis Tools 4D Views

• Autoalignmenttodefinestandardorientation of acquired 4D data

• Standardviews,suchas4CH,2CH,LAX,mitralvalveandaorticvalve,aredefined from the standard orientation

• Automaticdisplayofvolume renderings and 2D cut planes from standard views

• Smartstress:Automaticallysetupvarious scanning parameters (for instance geometry, frequency, gain,etc.)accordingtosame projection on previous level

• Scanmodesettings:Scanmode may be specified for individual views in the protocol

• Previewofstore:Showrunning loops as preview before storing to the examination

Continuous Capture

• Continuouslyacquirelarge amounts of 2D image data, and selection of projection views for analysis afterwards

• Theentirecontinuouscapture recording may be kept in memory while it is possible to store new images outside the protocol tem-plate, or the entire recording can be stored to file

• SelectionofprojectionviewsonScanner or EchoPAC when the entire recording is stored to file

Multi-plane Stress Echo

• Bi-planeand/ortri-planeacquisition

• Adjustmentofscan-planeangle and tilt during acquisition

• Individualscan-planesshowninanalysis – possible to show one scan-plane from each of the stress levels simultaneously

AFI Stress Echo (option)

• Singleortri-planeacquisitionof standard 2D apical views

• AnalysiswithdedicatedAFIstressanalysis tool

• Provideslongitudinalstrainvaluesper segment, as well as globally

• Allowscompleteassessmentataglance by combining three longitu-dinal views into one comprehensive bulls-eye view

• IntegratedintoM&A package with specialized report templates

• SimplifiedworkflowwithadaptiveROI,quicktipsandcombineddisplayof traces from all segments

Page 17: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June2015–DOC1564269 Page17of19

4D Data Cropping

• Flexibletoolforstandardordynamiccropping 4D data using up to six different crop planes

• Eachcropplanecanbemoved without any restrictions

• Thecropplanepositionsarevisible in both the volume rendering and in the 2D cut plane displays

Depth Render

• Volumevisualizationwherethe color hue changes according to the distance into the image

• Wideselectionofdifferent render maps

Stereo Render

• Volumevisualizationbystereoscopic display necessitates the use of stereoscopicglasses,bothred/cyanglasses for conventional StereoVision, and polarized glasses for Polarized stereo vision stereo rendering on dedicatedSony3Dmonitor

Multi-slice

• Simultaneousdisplayof5,7,9or12slices extracted from the 4D volume data(tissueand/orcolor)

• Combinationofshort-axisand long-axis standard views

• Availableinliveandreplay

FlexiSlice

• Simultaneousdisplayofthree independent random slices through the4Dvolume(tissueandcolor)

Safety Conformance• TheVividE95isbuilttomeettherequirementsof:

• IEC60601-2-37

• IEC60601-1

• IEC60601-1-2

• IEC60601-1-6

• UL60601-1

• CAN/CSA-C22.2No.60601-1

• NEMAUD3

6S-D Phased Array Probe

• Probepresets:Pediatric,cardiac, coronary, neonatal head, fetal heart, abdominal

12S-D Phased Array Probe

• Probepresets:Pediatric,neonatal,cardiac, coronary, neonatal head, abdominal, rodent

9L-DLinearArrayProbe

• Probepresets:Vascular(incl.carotid,LEA,LEV,UEA,UEV),musculoskeletal,thyroid, contrast (optional)

• Biopsyguide:Multi-angledisposablewith a reusable bracket

11L-DLinearArrayProbe

• Probepresets:Vascular(incl.carotid,LEA,LEV,UEA,UEV),breast,smallparts, musculoskeletal, thyroid, scrotal, rodent

• Biopsyguide:Multi-angledisposablewith a reusable bracket

C1-6-D XDclear CurvedArrayProbe(Convex)

• Probepresets:Abdominal,renal, OB/GYN,urology(pelvic),vascular(incl.aorto-iliac,LEA,LEV),fetalheart,contrast (optional)

• Biopsyguide:Multi-angle,disposablewith a reusable bracket

C2-9-D XDclear CurvedArrayProbe(Convex)

• Probepresets:Abdominal,renal, OB/GYN,urology(pelvic),fetalheart

• Biopsyguide:Multi-angle,disposablewith a reusable bracket

8C Micro Convex Probe

• Probepresets:Abdominal,vascular(incl.carotid,LEA,LEV,UEA,UEV),neonatal-head, musculoskeletal

IC5-9-DConvex(Endocavity)Probe

• Probepresets:OB/GYN,urology (pelvic),fetalheart

• Biopsyguide:Singleangle, disposable bracket

• TheEuropeanMedicalDevices Directive(MDD)93/42/EEC(CEMark)

• Directive2011/65/EUonthe restriction of use of certain hazardous substances

• TheVividE95ultrasoundunitisaClass I device, type CF, according to IEC60601-1

• TheVividE95ultrasoundunit meets the EMC requirements in EN55011/A1/A2:2007ClassA

Virus ProtectionTo reduce virus vulnerability, Vivid E95 is configured with a minimal set of open ports and with all network services not actively used by the system closed down. This helps to significantly reduce the risk of a virus attack on Vivid E95.

GE is continuously judging the need for additional actions to reduce vul- nerability of equipment; this includes vulnerability scanning of our products and evaluation of new security patches forthe3rd-partytechnologyused. Microsoft®(andother)securitypatchesthat address serious issues with Vivid E95 will be made available to customers after GE verification of those patches.

TransducersM5Sc-D XDclear Active Matrix Single Crystal Phased Array Probe

• Probepresets:Cardiac,pediatric,abdominal, fetal heart, cranial, coronary,stress(exercise,QstressandLVOstress),LVcontrast,renal,contrast now MI (optional)

• Biopsyguide:Multi-angledisposablewith a reusable bracket

4V-D Active Matrix 4D Volume Phased Array Probe

(NOTE: The option “4V Enable” is required to run this probe.)

• Probepresets:Cardiac,LVcontrast,LVOstress,fetalheart,exercisestress, coronary

Page 18: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

Vivid E95 product datasheet – June2015–DOC1564269 Page18of19

PROBE FREQUENCY RANGE CATALOG #

M5Sc-D(Sector) 1.4–4.6MHz H44901AE

6S-D(Sector) 2.4–8.0MHz H45021RR

12S-D(Sector) 4.0–12.0MHz H45021RT

4V-D(Volume) 1.5–4.0MHz H4001BT

9L-D(Linear) 2.4–10.0MHz H40442LM

11L-D(Linear) 4.5–12.0MHz H40432LN

L8-18i-D (LinearMatrixArray)

5.0–15.0MHz H40452LL

C1-6-D(Convex) 1.5–6.0MHz H40472LT

C2-9-D(Convex) 2.3–8.4MHz H40462LN

8C(MicroConvex) 4.0–8.0MHz H40412LJ

iC5-9-L (ConvexEndocavity)

3.3–8.6MHz H40442LK

P2D(Pencil) 2.0MHz H4830JE

P6D(Pencil) 6.3MHz H4830JG

6Tc(TEE)65 3.0–8.0MHz H45551ZD3

6Tc-RS(TEE)5 3.0–8.0MHz H45551ZE

6VT-D(VolumeTEE)5 3.0–8.0MHz H45581BJ4

9T(TEE)5 3.0–10.0MHz H45521DY

9T-RS(TEE)5 3.0–10.0MHz H45531YM

3 6Tc-RS and 9T-RS supported via probe adapter.

4 Also 6VT-D with catalog # H45561TA is supported.

5 TEE Interface option must be enabled for TEE probes to run.

L8-18i-DLinearArrayProbe

• Probepresets:Cardiac,rodent (incl.mice,rats),vascular, musculoskeletal, small parts

P2D Pencil Probe

• Probepresets:Cardiac

P6D Pencil Probe

• Probepresets:Vascular(LEA)

6Tc TEE Probe

• Probepresets:Cardiac,coronary

6VT-D TEE probe

• Probepresets:Cardiac, LVOcontrast,coronary

9T TEE Probe

• Probepresets:Pediatric

(NOTE: 6Tc-RS and 9T-RS supported via probe adapter.)

Wideband Probes• Electronicselectionbetweenfour

solid-state and one stand-alone Doppler probe connectors

• ThreeprobesocketsareDLPtypeplus one parking socket

• OneLogiqtypeconnectorprobe socketforsupportofTEEand8C

Page 19: Vivid E95 - Home - Davis Medical Electronics · resolution at large volume sizes in full ... The Vivid™ E95 combines the proven the Vivid product line with a new ... - Color video

DOC1564269

About GE HealthcareGEHealthcareprovidestransformationalmedicaltechnologies and services to meet the demand for increased access, enhanced quality and more affordable healthcarearoundtheworld.GE(NYSE:GE)worksonthings that matter – great people and technologies taking on tough challenges. From medical imaging, software & IT, patient monitoring and diagnostics to drug discovery, biopharmaceutical manufacturing technologies and performance improvement solutions, GEHealthcarehelpsmedicalprofessionalsdeliver great healthcare to their patients.

GEHealthcare9900 Innovation DriveWauwatosa,WI53226U.S.A.

www.gehealthcare.com

©2015 General Electric Company – All rights reserved.

June 2015

General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your GE representative for the most current information.

GE, GE monogram, Vivid, XDclear, EchoPAC, InSite and cSound are trademarks of General Electric Company or one of its subsidiaries.

DICOMistheregisteredtrademarkoftheNationalElectrical Manufacturers Association for its standards publications relating to digital communications of medical information.

WindowsandMicrosoftareregisteredtrademarksof Microsoft Corporation.

Sony is the registered trademark of Sony Corporation.

Third-party trademarks are the property of their respective owners.

GE Medical Systems Ultrasound & Primary Care Diagnostics,LLC,aGeneralElectricCompany, doingbusinessasGEHealthcare.