20

Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the
Page 2: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

Visionaire Lighting’s Evolution C Technology Is All About Performance

The Element II incorporates the flexible Vision bar technology which allows for LED fixture selection from 24 LEDs all the way to 288 LEDs in 24 LED increments

We at Visionaire Lighting have pioneered the highest benchmark for Solid State Lighting (SSL) technology in the industry.

We call this benchmark Evolution C; and we have officially incorporated it into this release of our newest, Element II family of LED luminaires.

Evo/C is the kind of comprehensive approach that only a lighting manufacturer with a decade-plus of production can advance.

Evo/C is more than just the lumen output of LEDs -- it’s more than the driver -- and it’s more than the housing.

Evo/C is synergy. It’s picking the best of everything; and constructing parts in-house when what is available isn’t good enough.

Evo/C is hiring the smartest engineers in the business to design, build, test; then re-test until a fixture meets Visionaire’s exacting standards.

Evo/C is about vertical integration within our own plant - Made in the USA.

Meet Element 2.0 Upon its introduction to the market a little over three years ago; the Element, Visionaire Lighting’s flagship LED fixture, simply took off. Now, after hundreds of Element projects have been installed around the globe, we’re taking our best-selling LED luminaire and making it even better. What’s New? The Element II’s quality is visually apparent as soon as it is table-topped alongside a competitor’s fixture. Enhanced areas include:

• Aluminum end caps, which are die cast for strength; and enhanced with design elements for a pleasingly sophisticated look.• Additional, advanced optics that leap ahead of the competition; giving the Element II the leading edge in nearly every desired application.• More housing sizes for increased scale-ability.• Two new low-profile end mount arms designed to enhance the beauty of the Element II while adding function for higher lumen lighting applications.

Page 3: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

More Tailored Mounting Options For Maximum Versatility

Q1EL2-MA

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONAL ±ANGULAR: ± 1 °TWO PLACE DECIMAL ± .03THREE PLACE DECIMAL ± .015

INTERPRET GEOMETRICTOLERANCING PER:

MATERIAL

FINISH

DRAWN

CHECKED

ENG APPR.

MFG APPR.

Q.A.

COMMENTS:

DATENAME

TITLE:

SIZE

BDWG. NO. REV

WEIGHT:SCALE: 1:4

UNLESS OTHERWISE SPECIFIED:

SHEET 1 OF 1DO NOT SCALE DRAWING

VISIONAIRE LIGHTING19645 RANCHO WAY , RANCHO DOMINGUEZ, CA 90220

PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OFVISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.

A

Q1EL2-PM

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONAL ±ANGULAR: ± 1 °TWO PLACE DECIMAL ± .03THREE PLACE DECIMAL ± .015

INTERPRET GEOMETRICTOLERANCING PER:

MATERIAL

FINISH

DRAWN

CHECKED

ENG APPR.

MFG APPR.

Q.A.

COMMENTS:

DATENAME

TITLE:

SIZE

BDWG. NO. REV

WEIGHT:SCALE: 1:4

UNLESS OTHERWISE SPECIFIED:

SHEET 1 OF 1DO NOT SCALE DRAWING

VISIONAIRE LIGHTING19645 RANCHO WAY , RANCHO DOMINGUEZ, CA 90220

PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OFVISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.

Q1EL2-PM

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONAL ±ANGULAR: ± 1 °TWO PLACE DECIMAL ± .03THREE PLACE DECIMAL ± .015

INTERPRET GEOMETRICTOLERANCING PER:

MATERIAL

FINISH

DRAWN

CHECKED

ENG APPR.

MFG APPR.

Q.A.

COMMENTS:

DATENAME

TITLE:

SIZE

BDWG. NO. REV

WEIGHT:SCALE: 1:4

UNLESS OTHERWISE SPECIFIED:

SHEET 1 OF 1DO NOT SCALE DRAWING

VISIONAIRE LIGHTING19645 RANCHO WAY , RANCHO DOMINGUEZ, CA 90220

PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OFVISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.

Mast Arm Fitter End MountBolt-On Arm Quick Mount

Bolt-On Arm Wall Mount

Ceiling Mount

Pendant MountMast Arm

End Mount (Side) End Mount (Front)

1.

Page 4: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

2.

Page 5: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

3.

Page 6: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

TESTED FOR LIFEThe secret to the Element II’s advanced efficiency is superior heat reduction.

To get there, we built a powerhouse of a heat sink, and designed it to make maximum use of the Venturi Effect.

Sinking the Heat – Successfully

In LED luminaires, the most critical areas to cool are the junction points where the LEDs meet the circuit board. The heat sink is used to draw heat away from these points.

The Element II’s extruded aluminum heat sink is substantial.

With a maximized fin ratio and precisely-mapped channel distributions; thermal build-up peels away from the Element II’s junction points, allowing for cooler operation.

Feel the Breeze – the Venturi Effect

The Venturi Effect dictates that, with increased air flow, heat transfer rates increase exponentially, removing heat at ever-faster rates.

Hold your hand over the Element II, and feel it — that rush of air rising up through the fixture, and out the top.

Engineering for this effect cools LEDs, drivers and internal components; allowing the Element II to:

• Withstand higher ambient temperatures. • Withstand higher drive currents. • Achieve a low thermal resistance rating. • Extend LED life.

This effect doesn’t occur with external, decorative heat sinks -- like those found in competing products.

Combining heat sink technology with the Venturi Effect produces a superior, long-lasting product with increased light output.

4.

Page 7: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

Element II, Size 1Drive current of 350mA yields an L70 of 150,000 hours. Drive current of 530mA yields an L70 of 100,000 hours.

Element II, Size 2Drive current of 350mA yields an L70 of 150,000 hours. Drive current of 530mA yields an L70 of 100,000 hours.

Element II, Size 3Drive current of 350mA yields an L70 of 150,000 hours. Drive current of 530mA yields an L70 of 100,000 hours.

Element II, Size 4Drive current of 350mA yields an L70 of 150,000 hours. Drive current of 530mA yields an L70 of 100,000 hours.

Element II, Size 5Drive current of 350mA yields an L70 of 150,000 hours.

5.

Page 8: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

Pioneering the Benchmark for Ultimate LED Performance

Visionaire Lighting’s Evolution C benchmark of luminaires features the highest-lumen-output Light Emitting Diodes on the market, outfitted with our proprietary, cutting edge optics (patents pending).

Here’s why:

1. Highest available lumens per watt for maximum efficiency.

2. Improved CRI (Color Rendering Index) for truer colors.

3. Tighter color binning for maximum Kelvin uniformity.

4. Lower forward voltages means lower system watts for increased efficiency (Lumens/Watt).

5. Longer life for 350 and 530 mA.

6. Marginal decreases in efficiency between 350 and 530 mA.

The Element II’s VisionBarTM LED light assemblies come in multiples of 24 (minimum 24 to maximum 288 LEDs), and are field replaceable.

No other outdoor lighting manufacturer can offer your project more efficient, cost-effective and application-specific LED lighting solutions.

Superior Kelvin and CRI

The Element II is offered in two highly desirable Kelvin temperatures, 4000K and 5500K. We have selected these two Kelvin temperatures as standard because 4000K matches the Kelvin of typical metal halide fixtures and 5500K yields a bluer white color which enhances car dealerships and lower wattage applications. Both Kelvins have similar lumen output. The CRI of the 4000K LEDs are 70 and the CRI of the 5500K LEDs are 75. Please consult factory for additional Kelvin temperatures which can be ordered as well as LEDs with higher CRIs.

The Color Rendering Index, or CRI, is a measure of the quality of color light as the human eye sees it.

Driver Power

The Element II is powered by a choice of 350 or 530 mA high-performance Constant Current Philips Advance Xitanium LED drivers, which accept 120v thru 277v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40 oC operations. Expected life of the driver ranges from 100,000 to 150,000 hours.

1) The LED driver reduces output power to LEDs if its maximum allowable case temperature is exceeded. 2) The LED driver complies with UL standard UL1012. 3) The LED driver has a Class A sound rating. 4) As an option the LED drivers come dimming enabled with a 0-10 volt input. 5) The LED driver has a THD (Total Harmonic Distortion) of less than 20%.

Evolution C

6.

Page 9: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

Why Dim LEDs?Dimming LEDs save energy at an approximate 1:1 ratio. This means by dimming the LEDs to 50% of their light output, the LEDs’ energy usage will decrease by nearly 50%. Dimming LEDs also makes them run cooler, which extends the life of the driver, as well as doubling or tripling the LEDs lumen maintenance. Select the dimming type, then schedule settings and, in the case of Dual Circuit, add optional motion sensor. LED luminaires really earn their worth when controls are applied. Consider choosing one of the following options to achieve the ultimate return on your investment.

1. Analog 0 – 10 Volt

A pre-installed 0 - 10 volt driver enables the fixture to be operated by a separately-provided control system.

2. Dual Circuit (DC)

Separate driver circuits provide two levels of light (high and low) without requiring a controller. Can be tied to an optional motion sensor.

Examples:

• Two drivers a 50% reduction in output. • Three drivers a 33% or 67% reduction in output.

3. Event-Based Dimming (EB)

Luminaires arrive installed with controls that are pre-programmed to trigger up to five, timed events of varying dimming percentages.

See the Event-Based Dimming Example Chart below.

4. Wireless Controls (WC)

Enables event-based dimming to be modified remotely after pre-programmed fixtures are installed.

• Triggers up to 32 events. • Provides outage notifications. • Monitors energy consumption. Optional Motion Sensor

Activity close to the luminaire triggers an event of 100% brightness lasting for several minutes. Afterwards, illumination returns to the level of the current event.

7.

Page 10: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

8.

Page 11: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

Performance Starts with Optics that Outpace All Others

Visionaire Lighting’s proprietary optics are the industry leader. Patent pending lens designs produced in-house simply can’t be duplicated by others. Painstakingly developed by our Photometrics team, these nine optic types give the Element II an edge; allowing us to manufacture fixtures that illuminate beautifully at lower wattages and wider pole spacings. To learn more, visit our Photometrics website section; or call us for layout assistance.

A Superior Line-up of Optics

Optics Isolux Pattern Best Application(s) Key Feature(s)

Type

I

I

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21• One- and two-lane roadways.• Long pedestrian paths.• Warehouse aisles.

Enables pole spreads at six to eight times mounting height to achieve intersection.

Type

II II

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21• Parking lots.• Street-adjacent back lots.

Best where sideways light is required at light levels greater than one Footcandle.

II-R

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21

• Two-, three- and four-lane roadways.

Optimal for staggered light spacing requirements.

Type

III

III

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21

• Four- to six-lane roadways.• Cross walks.• Site perimeters.

Designed for side light, 45o light, and forward light applications requiring light levels of one or more Footcandles.

Type

IV

IV

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21

• Shopping centers.• Office complexes.

Effective for forward-light applications that require a half a Footcandle or more across distances.

IV-A

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21

• Auto dealerships.• High-brightness inspection

areas.

Best where a combination of high Footcandles at low wattages are required.

IV+CLS

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21

• LEEDs projects. Useful for projects requiring pristine back light control and zero light trespass.

Type

V V

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21• High-clearance parking

structures.Excellent for low mounting-height installations requiring minimums of one Footcandle.

V-W

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21

• Low-clearance parking structures.

• Outdoor parking areas.

Best for 400+ wattage requirements, and retrofitting vertical lamp fixtures at typical 120x120 or 180 x180 spacings.

A = Automotive . R = Roadway . W = Wide . +CLS = with external Cutoff Louver Shield option.For additional LEEDS-qualifying shields, please consult factory.

9.

Page 12: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

Twin Element II Fixtures - End Mount

EL2-4-T5W-168LC-530-4000K

275 system watts

Type Five Wide distribution

120 foot by 120 foot spacing

33 foot mounting height

Full cutoff

Our new Type Five optic designed for large parking lots enables 400 watt fixtures to be replaced at a lower wattage without photopic light level sacrifice with improved uniformity.

10.

Page 13: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

Our new Type Four optic with Cutoff Louver System is designed for the most stringent light trespass criteria, cutting the light behind the luminaire to .01 foot candles at 3/4 mounting height.

Single Element II Fixture - Bolt-On Arm

EL2-3-T4-120LC-530-4000K-CLS

190 system watts

Type Four distribution with Cutoff Louver System

60 foot spacing

25 foot mounting height

Full cutoff

11.

Page 14: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

(LIFE) Let us Find the Perfect Balance for Your Specific ApplicationThe L70

test determines the point in an LED’s life when it reaches 70 percent of its initial output. Element II series LEDs have been determined to last 150,000+ hours in 40 oC environments when driven at 350 mA.

At Visionaire Lighting, we have discovered that the secret to the perfect LED fixture fit is to determine the perfect balance between number of VisionBarsTM and the milliamps to drive them at.

More Lumens per Dollar

In an exceptionally well-cooled fixture like the Element II, it becomes possible to drive fewer LEDs at higher milliamps. Fewer LEDs putting out more lumens creates the right amount of light for the job, while at the same time reducing the initial cost of the luminaire.

12.

Page 15: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

HID to LED Crossovers Return on Investment (ROI) per single fixture retrofit. A Brilliant Performer FINANCIALLY, TOO!

Street Lighting Crossovers

Existing Wattage

System Watts

HPS Life Hours

Proposed Element II

ConfigurationSystem Watts

LED L70 Life Hours

Watts Saved

Energy Saved

10 Year Energy

Savings*

10 Year Maintenance Payback**

10 Year Total

Savings**

400 HPS 464 24,000 EL2-3-120LC-530 190 100,000 274 59% $1,434 $332 $1,766

250 HPS 295 24,000 EL2-1-96LC-530 152 100,000 143 48% $750 $332 $1,082

200 HPS 250 24,000 EL2-1-72LC-530 114 100,000 136 54% $710 $332 $1,042

150 HPS 188 24,000 EL2-1-72LC-530 114 100,000 74 39% $380 $332 $712

100 HPS 130 24,000 EL2-1-48LC-530 76 100,000 54 41% $270 $332 $602

70 HPS 91 24,000 EL2-1-48LC-350 56 150,000 35 38% $170 $332 $502

*Savings calculated on 12 hours of usage/night, 7 nights/week, at 12¢/kilowatt-hour.**Estimated cost of replacing 1 HPS lamp every 6 years, including equipment rental, parts and labor.

Parking Lot Lighting Crossovers

Existing Wattage

System Watts

MH Life Hours

Proposed Element II

ConfigurationSystem Watts

LED L70 Life Hours

Watts Saved

Energy Saved

10 Year Energy

Savings*

10 YearMaintenance Payback**

10 YearTotal

Savings**

400 MH 458 20,000 EL2-3-144LC-530 228 100,000 230 50% $1,500 $398 $1,898

250 MH 295 20,000 EL2-1-96LC-530 152 100,000 143 48% $935 $398 $1,333

175 MH 210 15,000 EL2-1-72LC-530 114 100,000 96 45% $630 $398 $1,028

100 MH 129 20,000 EL2-1-48LC-530 76 100,000 53 41% $350 $398 $748

70 MH 90 12,000 EL2-1-48LC-350 56 150,000 34 37% $220 $398 $618

*Savings based on 12 hours of usage/night, 7 nights/week, at 12¢/kilowatt-hour.**Estimated cost of replacing 1 MH lamp every 5 years, including equipment rental, parts and labor.

Parking Garage Lighting Crossovers

Existing Wattage

System Watts

MH Life Hours

Proposed Element II

ConfigurationSystem Watts

LED L70 Life Hours

Watts Saved

Energy Saved

10 Year Energy

Savings*

10 YearMaintenance Payback**

10 YearTotal

Savings**

175 MH 210 15,000 EL2-1-48LC-530 76 100,000 134 64% $1,769 $500 $2,269

175 MH 210 15,000 EL2-1-72LC-350 84 150,000 126 60% $1,663 $500 $2,163

150 MH 188 15,000 EL2-1-48LC-530 76 100,000 112 60% $1,478 $500 $1,978

150 MH 188 15,000 EL2-1-72LC-350 84 150,000 104 55% $1,373 $500 $1,873

100 MH 129 20,000 EL2-1-48LC-350 56 150,000 73 57% $964 $500 $1,464

70 MH 90 12,000 EL2-1-24LC-530 38 100,000 52 58% $686 $500 $1,186

*Savings based on 24 hours of usage/night, 7 nights/week, at 12¢/kilowatt-hour.**Estimated cost of replacing 1 MH lamp every 2.5 years, including parts and labor.

13.

Page 16: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

EL2-1 18”

32½”

38”42”

28½”

48½”

24”4” 21½”14½” 96 34

EL2-S 14” 4” 21½”14½” 72 30Fixture A B C D LbsMax. LEDs

EL2-2 4” 21½” 144 3814½”28”32”38”

EL2-3 EL2-4 EL2-5

4”4”4”

416268

21½”21½”21½”

144192288

14½”14½”14½”

En/a

Top View Side View/End Cap

B

A

B

C

A

B D

C

Front View

Side ViewBOLT-ON ARM

EA

AE

Side View - EMAF

Side View - EBOA

Area

Garage/Canopy

Model Optics Source KelvinMilliamps Mounting Finish OptionsBolt-On Arm

(BOA)

Wall Mount*Includes Cast Wall Plate

(WM)

Knuckle Mount*Slips over 2 3/8” Tenon

with adjustable Incrementsof 10˚

(KM)

Mast Arm Fitter(MAF)

Ceiling Mount(CM)

Pendant Mount*Specify pendant Iength

(PM)

End Mount Bolt-On(EBOA)

End Mount*Requires 2-3/8”horizontal tenon

(EMAF)

White(WH)

Bronze(BZ)

Black(BK)

Grey(GY)

Silver Metallic(SL)

Custom Color(CC)

Voltage120-277

*Universal voltage(UNV)

480(5)

347(8)

4000K*Neutralwhite(4K)

5500K*Coolwhite

(55K)

EL2-S

EL2-1

EL2-2

EL2-3

mA

350 530 350 530 350 n/a (3) (5)

350 530 350 530 350 530 350 530 (3) (5)

350 350 (3)

530 530 (5)

# of LEDs

24 (24LC)48 (48LC)72 (72LC)

24 (24LC)48 (48LC)72 (72LC)96 (96LC)

120 (120LC)144 (144LC)

120 (120LC)144 (144LC)

Type I(T1)

Type II(T2)

Type II-R(T2R)

Type III(T3)

Type IV(T4)

Type IV-A(T4A)

Type V(T5)

Type V-W(T5W)

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

21

Type IV Type II Type VType IIIType I

5W

5

4-A

4

4+CLS

3-R

3

2-R

2

Type IV Type II Type VType III

5W

5

4-A

4

4+CLS

3-R

3

Type IV Type VType III

5W

5

4-A

4

4+CLS

EL2-4*End mount only

EL2-5*End mount only

168 (168LC)192 (192LC)

216 (216LC)240 (240LC)264 (264LC)288 (288LC)

350 530 350 530 (3) (5)

350 350 350 350 (3)

0-10v Dimming DriverNo Controls

(DIM)

Photocell & Receptacle*Specify voltage

(PCR120) (PCR208)(PCR240) (PCR277)

Photo Receptacle (PER)*With shorting cap

Button Type Photocell*Specify voltage

(PC120) (PC208)(PC240) (PC277)

Round Pole Plate AdaptorFor 4ӯ Pole (RPP4)For 5ӯ Pole (RPP5)

Element Conduit Box(ECB)

Cutoff Louver System(CLS)

Vandal Resistant Shield(VRS)

Dual Circuit(DC)

Motion Sensor(MS)

10KV Surge Protector(10KV)

14. 10.20.14

Page 17: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

Housing• The fixture housing is heavy-duty, extruded aluminum, with heat radiating fins. A perforated aluminum top cover, beneath a protective debris guard, protects the heat radiating fins from contaminants and directs constant air flow over them for maximum cooling.

Thermal Management• The Element II provides excellent overall thermal management by maximizing the fixture’s heat sink efficiency. This enables the Element II to withstand higher ambient temperatures and drive currents without degrading LED life. The Element II has a low thermal resistance rating. The heat radiating fins and perforated fixture components create superior thermal management results.• The L70 test determines the point in an LEDs life when it reaches 70 percent of its initial output. Element II series LEDs have been determined to last 150,000+ hours in 40 oC environments when driven at 350 mA. See LED Data Chart for additional test results.

Optical System• The highest lumen output LEDs available are utilized in the Element II series. IES Types III and V distributions are standard. The LED VisionBarTM light assemblies come in multiples of 24 (minimum 24 to maximum 288 LEDs) and are field replaceable. The optical system qualifies as IES full cutoff; and is Dark-Sky certified to restrict light trespass, glare and light pollution.

Quali-Guard® Finish• A Quali-Guard® thermoset polyester powder coat painted finish is available in white and custom colors.

Mounting - Area•BOA- The cast aluminum Bolt-on Arm is shipped mounted to the fixture. A pole plate is supplied for mounting to the pole; which allows for quick and easy fixture installation with two set screws.

•WM- Galvanized steel wall mount bracket can be secured directly to recessed junction box or the wall. The fixture is supplied with a shortened arm bracket to keep the fixture closer to the wall.

•CM- Steel ceiling mount bracket can be secured directly to recessed junction box, or to the ceiling. The housing hanger bracket allows fixture to be suspended from ceiling bracket while making wiring connection. The housing bracket then attaches to the ceiling bracket via a tool-less latch. A tamper-proof screw can then secure the bracket.

•KM- Knuckle Mount will mount over a 2” horizontal or vertical tenon and is field adjustable in increments of 5°

•MAF- Mast arm fitter is provided with a cast aluminum arm adaptor designed to slip fit over a 1¼” to 2” horizontal tenon (mast arm) and is adjustable +/- 5 degrees for fixture leveling.

An internal clamping device provides a secure attachment to the mast arm, eliminating the need to drill for thru-bolt attachment.

•EBOA- End Mount version utilizing the same Quick Mount pole adaptor for a bolt-on application

•EMAF- End Mount Mast Arm Fitter is provided with a cast aluminum arm adaptor designed to slip fit over a 2” horizontal tenon (mast arm) and is fully adjustable.

A round pole plate adaptor is required for mounting to a 3”- 6” round pole.

Mounting - Roadway• The Element II - Roadway is provided with a cast aluminum arm adaptor designed to slip fit over a 1¼” to 2” horizontal tenon (mast arm) and is adjustable +/- 5 degrees for fixture leveling. An internal clamping device provides a secure attachment to the mast arm, eliminating the need to drill for thru-bolt attachment.

Mounting - Garage/Canopy• Steel ceiling mount bracket can be secured directly to recessed junction box, or to the ceiling. The housing hanger bracket allows fixture to be suspended from ceiling bracket while making wiring connection. The housing bracket then attaches to the ceiling bracket via a tool-less latch. A tamper-proof screw can then secure the bracket.

Electrical Assembly• The Element II is supplied with a choice of 350 or 530 mA high-performance LED drivers that accept 120 v thru 277 v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40 oC operations.

Warranty• Five (5) year Limited Warranty on entire system, including finish. For full warranty information, visit VisionaireLighting.com.

Options• 0-10v Dimming Driver• Photocell & receptacle • Cutoff louver system• Photo receptacle • Vandal-resistant shield• Button type photocell • Dual circuit • Round pole plate adaptor • Motion sensor• Element conduit box Please consult factory for custom options and available upgrades

Listings• Element II is ETL listed, suitable for wet locations.• LM79 and LM80. • IP65 Listed. • Meets ANSI C136.31-2001 Vibration Standards at 2G when

ordered with the MAF mounting option.• RoHS compliant.• Powder Coated ToughTM .

EPA Data

05.09.11 ~ Added 3 “n/a”s to ELE-2.

EPA Data

Fixturewith Arm

End Mount Only

End Mount Only

.6

.7

.8

.9

1.2

1.3

1.3

1.3

1.3

1.3

2.4

2.3

1.1

1.2

1.4

1.5

2.7

2.7

1.1

1.2

1.4

1.5

2.6

2.6

.8

.9

1.0

1.2

1.6

1.7

1.1

1.2

1.4

1.5

2.6

2.7

EL2-S

EL2-1

EL2-2

EL2-3

EL2-4

EL2-5

15.

Page 18: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

LED Data ChartLED Data Chart for 5500K*

# Bars # LEDsOutput

mA

Initial LumensType 1

InitialLumensType 2

InitialLumensType 2R

InitialLumens Type 3

InitialLumens Type 4

InitialLumensType 4A

InitialLumens Type 5

InitialLumensType 5W

System Watts

120-277L

70 Hours

@ 40° C

1EL2-1

24350 2263 2362 2226 2250 2262 2352 2375 2380 28 150,000

530 2520 2841 2470 2776 2684 2691 3030 3047 38 100,000

2EL2-1

48350 4526 4724 4452 4501 4525 4704 4750 4760 56 150,000

530 5042 5683 4940 5553 5368 5382 6087 6094 76 100,000

3EL2-1

72350 6789 7086 6678 6483 6786 7056 7125 7140 84 150,000

530 7563 8524 7410 8330 8052 8073 9128 9141 114 100,000

4EL2-1

96350 9052 9448 8904 8645 9048 9408 9500 9520 112 150,000

530 9923 11365 9880 11107 10736 10764 12174 12188 152 100,000

5EL2-2

120 350 11315 11810 11130 10212 11310 11760 11875 11900 140 150,000

5EL2-3

120 530 12405 14207 12350 13884 13440 13457 15216 15235 190 100,000

6EL2-2

144 350 13588 14172 13356 12255 13572 14112 14250 14280 168 150,000

6EL2-3

144 530 14885 17048 14820 15260 16128 16146 18260 18816 228 100,000

7EL2-4

168350 15841 16534 15582 14297 15834 16464 16625 16640 196 150,000

530 17367 19890 17290 17803 18788 18837 19418 21818 266 100,000

8EL2-4

192350 18105 18896 17808 16341 18096 18816 19000 19040 224 150,000

530 19847 22780 19760 20000 21472 21528 22191 24366 304 100,000

9EL2-5

216 350 20367 21258 20034 20560 20358 20168 21004 21420 252 150,000

10EL2-5

240 350 22630 23620 22260 22600 22620 23520 23008 23800 280 150,000

11EL2-5

264 350 24893 25982 24486 24640 24882 25872 25012 26180 308 150,000

12EL2-5

288 350 27176 28344 26712 26680 27144 28224 27016 28560 336 150,000

Visit www.VisionaireLighting.com for up-to-the-minute chart information, including types not listed here.* For 4000K multiply values by 0.90

03.07.12

16.

Page 19: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the

ETL Certified

The ETL Listed Mark is proof of product compliance to North American safety standards. Authorities Having Jurisdiction (AHJ’s) in 50 states and Canada and retailers accept the ETL Listed Mark as proof of product safety. Safety standard test practices conform to UL, ANSI, CSA, ASTM, NFPA, and NOM.

IP65 Rated

As defined in international standard IEC 60529, IP Code classifies and rates the degrees of protection provided against the intrusion of solid objects, dust, accidental contact, and water in mechanical casings and with electrical enclosures.

RoHS Certified

The RoHS directive aims to restrict certain dangerous substances commonly used in electronic equipment. Any RoHS compliant component must have 100ppm or less of mercury.

ANSI Certified

The Element II is ANSI C136.31-2001 certified for luminaire vibration at 2G.

A Product That’s Road Tested

17.

Page 20: Visionaire Lighting’s Evolution Cadvanteklighting.ca/wp-content/uploads/2016/01/... · Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the