1

Click here to load reader

Viking Pump Nozzle Load Details

Embed Size (px)

DESCRIPTION

Viking Pump

Citation preview

  • TECHNICAL REFERENCE

    TR NO. TR-100 PAGE: REVISION: F REV. DATE: 30 Dec 2013

    TITLE: Allowable Nozzle Loading (Forces & Moments)

    VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA 50613 U.S.A.

    8

    Series 724, 4724

    (4724 PUMP SHOWN IN DRAWING) LOADING COORDINATE SYSTEM: X: PARALLEL TO PUMP SHAFT Y: VERTICAL, PERPENDICULAR TO PUMP SHAFT Z: HORIZONTAL, PERPENDICULAR TO PUMP SHAFT

    P: FORCES (LBF / N) M: MOMENTS (FT-LBF / N-m)

    PUMP SIZE (FLANGE SIZE)

    PORT A

    PORT B

    Px Py Pz Mx My Mz Px Py Pz Mx My Mz

    F (0.5) &FH8,9 (0.75) 100 445 105 465

    120 535

    25 35

    10 14

    25 35

    100 445

    105 465

    120 535

    25 35

    10 14

    25 35

    G8,9 (1) 85

    375 95

    420 120 535

    25 35

    10 14

    25 35

    85 375

    95 420

    120 535

    25 35

    10 14

    25 35

    H&HL9 (1.5) 360 1600 360

    1600 360

    1600 230 300

    90 120

    25 35

    360 1600

    360 1600

    360 1600

    230 300

    25 35

    90 120

    K,KK&L9 (2) 420 1870 420

    1870 420 1870

    440 600

    150 200

    50 70

    420 1870

    420 1870

    420 1870

    440 600

    50 70

    150 200

    LQ (2.5) &LL (3) 450 1950 450

    1950 450 1950

    485 650

    195 260

    220 300

    450 1950

    450 1950

    450 1950

    485 650

    195 260

    220 300

    8Pump has opposite ports. Port B is directly opposite Port A. 9Pumps have tapped ports