11
107051 SECTION 10705 EXTERIOR SUN CONTROL DEVICES Display hidden notes to specifier in Word 2010 by: Click File > Options > Display > Under “Always show these” select “Hidden Text” © 2015 Structureworks Fabrication– All rights reserved ** NOTE TO SPECIFIER ** This section is based on the products of Structureworks Fabrication, which is located at: 3300 Dill Smith Dr. Fredericksburg, VA 22408 877.489.8064 [email protected] www.structureworksfab.com PART 1 GENERAL 1.1. SECTION INCLUDES ** NOTE TO SPECIFIER ** Delete items below not required for project. A. Structural Pergola Components. B. Pergola Footings. C. Pergola Canopy Systems. 1.2. RELATED SECTIONS ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section 02300 Earthwork: Excavation and backfill. B. Section 03300 Cast in Place Concrete: Foundations and floor slab. C. Section 09900 Painting: Paint and stain field applied finish. 1.3. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section. A. ASTM E 84 Standard Test Method for Surface Burning Characteristics of

· Web viewDesign members to withstand wind loads in accordance with ASCE 710 and applicable code. Design foundations in accordance with applicable code and good construction practices

Embed Size (px)

Citation preview

Page 1: · Web viewDesign members to withstand wind loads in accordance with ASCE 710 and applicable code. Design foundations in accordance with applicable code and good construction practices

107051

SECTION 10705 EXTERIOR

SUN CONTROL DEVICES

Display hidden notes to specifier in Word 2010 by:Click File > Options > Display > Under “Always show these” select “Hidden Text”

© 2015 Structureworks Fabrication– All rights reserved

** NOTE TO SPECIFIER **This section is based on the products of Structureworks Fabrication, which is located at:3300 Dill Smith Dr.Fredericksburg, VA [email protected] www.structureworks-fab.com

PART 1 GENERAL

1.1. SECTION INCLUDES** NOTE TO SPECIFIER ** Delete items below not required for project.

A. Structural Pergola Components.

B. Pergola Footings.

C. Pergola Canopy Systems.

1.2. RELATED SECTIONS** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

A. Section 02300 Earthwork: Excavation and backfill.

B. Section 03300 Cast in Place Concrete: Foundations and floor slab.

C. Section 09900 Painting: Paint and stain field applied finish.

1.3. REFERENCES** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

A. ASTM E 84 Standard Test Method for Surface Burning Characteristics of Building Materials.

B. ASCE 710 American Society of Civil Engineers, Minimum Design Loads for Buildings and other structures.

1.4. DESIGN/PERFORMANCE REQUIREMENTS

A. Design members to withstand wind loads in accordance with ASCE 710 and applicable code.

B. Design foundations in accordance with applicable code and good construction practices for the specific structure and site conditions.

C. Cooperate with regulatory agency or authority and provide data as requested.

Page 2: · Web viewDesign members to withstand wind loads in accordance with ASCE 710 and applicable code. Design foundations in accordance with applicable code and good construction practices

107052

D. Design pergola for required allowable ground snow load in accordance with the applicable code.

E. Design pergola in accordance with applicable fire code and provide data on ASTM E 84 testing performance.

1.5. SUBMITTALS

A. Submit under provisions of Section 01300.

B. Product Data: Manufacturer's data sheets on each product to be used, including:1. Product specification sheets.2. Installation instructions.

C. Shop Drawings: Indicate assembly dimensions, locations of structural members, connections, and general construction details, anchorages and method of anchorage, and method of installation.

** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.

D. Selection Samples: For each finish product specified, two complete sets of color samples representing manufacturer's full range of available colors.

E. Verification Samples: For each finish product specified, two samples representing actual product and color.

1.6. QUALITY ASSURANCE

A. Manufacturer Qualifications: Single source manufacturer for design, engineering, structure fabrication, and shipping.

B. Installer Qualifications: Familiar with manufacturer's structures and installation techniques.

1.7. DELIVERY, STORAGE, AND HANDLING

A. All packages and pallets should be opened and inspected for hidden damage upon receipt. Any missing or damaged components should be noted on the delivery receipt with the carrier before accepting the shipment.

B. Repackage components and carefully store in an area protected from the weather until ready for installation.

C. Handle materials so as to protect materials, coatings, and finishes during transportation and installation to prevent damage or staining.

1.8. SEQUENCING

A. Ensure that footing location plans and other information required for installation of products of this section are furnished to affected trades in time to prevent interruption of construction progress.

B. Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.

1.9. WARRANTY

A. Provide manufacturer’s warranties, as appropriate, for all pergola components, canopy systems, and finish coatings.

1. 30 Year Limited commercial warranty on fiberglass pergolas.2. Limited Lifetime residential warranty on fiberglass pergolas.3. 5 Year Limited commercial warranty on aluminum pergolas.4. 10 Year Limited residential warranty on aluminum pergolas.5. 5 Year Limited commercial warranty on Ultra Fuse powder coat.

Page 3: · Web viewDesign members to withstand wind loads in accordance with ASCE 710 and applicable code. Design foundations in accordance with applicable code and good construction practices

107053

6. 20 Year Limited residential/commercial warranty on ColorLast paint.

Page 4: · Web viewDesign members to withstand wind loads in accordance with ASCE 710 and applicable code. Design foundations in accordance with applicable code and good construction practices

107054

6. 1 Year Limited warranty on manually retractable canopy system.7. 1 Year Limited warranty on tensioned fabric canopy system.

PART 2 PRODUCTS

1.1. MANUFACTURERS

A. Acceptable Manufacturer: Structureworks Fabrication, which is located at: 3300 Dill Smith Dr.; Fredericksburg, VA 22408, 877.489.8064, 877.489.2009, www.structureworksfab.com

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with re-quirements of Division 1 section on product options and substitutions.

B. Substitutions: Not permitted.

C. Requests for substitutions will be considered in accordance with provisions of Section 01600.

1.2. MATERIALS

A. Provide the following pergolas to the overall sizes and configuration indicated on the Drawings. ** NOTE TO SPECIFIER ** Select the following configuration options and sizes as required from the following paragraphs and delete those not required. If more than one type is required clearly indicated the location of each on the Drawings. Contact manufacturer for custom sizes and configurations as required and insert options/size(s) required.

B. Attachment Method.1. Attached to host structure.2. Freestanding.

C. Overall width (direction of beam) of pergola: .

D. Overall projection (direction of rafters) of pergola: .

E. Column Selection1. Fiberglass 10” x 8’ High Round Tapered Column with TensionRod and Aluminum Plate

Mounting System.2. Fiberglass 12” x 10’ High Round Tapered Column with TensionRod and Aluminum Plate

Mounting System.3. Fiberglass 12” x 8’ High Square Tapered Column with TensionRod and Aluminum Plate

Mounting System.4. Fiberglass 8” x 8” x 8’ High Square Straight Column with TensionRod and Aluminum Plate

Mounting System.5. Fiberglass 10” x 10” x 8’ High Square Straight Column with TensionRod Mounting System.6. Fiberglass 8” x 8” x 8’ High Square Column with 15” x 15” x 36” High Column Base and

TensionRod and Aluminum Plate Mounting System.7. Aluminum 4” x 4” x 8’ High Post with Mounting Brackets8. Aluminum 5” x 5” x 8’ High Post with Mounting Brackets9. Aluminum 6” x 6” x 8’ High Post with Mounting Brackets10. Aluminum 8” x 8” x 8’ High Post with Mounting Brackets11. Custom Fiberglass Column with TensionRod and Aluminum Plate Mounting System.:

” x ” x ’ High.12. Custom Aluminum Post With Mounting Brackets.: ” x ” x ’ High.

F. Beam Component Selection.

Page 5: · Web viewDesign members to withstand wind loads in accordance with ASCE 710 and applicable code. Design foundations in accordance with applicable code and good construction practices

107055

F. Beam Component Selection.

1. 2” x 8” Fiberglass.2. 2” x 8” Aluminum.3. Custom Material: .

G. Rafter Component Selection.1. 2” x 8” Fiberglass.2. 2” x 8” Aluminum.3. Custom Material: .

H. Stringer Component Selection.1. 1 ¾” x 1 ¾” Fiberglass.2. 1 ¾” x 1 ¾” Aluminum.3. Custom Material: .

I. Hardware.1. All exposed hardware to be stainless steel or aluminum.

J. Canopy System.1. Tensioned Fabric Pergola Canopy System.

a. Specify fabric name: .2. Manually Retractable Pergola Canopy System.

a. Specify fabric name: .

1.3. FINISH** NOTE TO SPECIFIER ** Select the finishing option required from the following paragraphs and delete those not required.

A. Provide all pergola components (columns, beams, rafters, and stringers) with Ultra Fuse powder coat finish applied.

1. Specify standard color: White Lite, Titanium, Night, Verssilles, Pompeiian Gold, Java, Mica, Latte.

2. Specify custom color: .

B. Provide all pergola components (columns, beams, rafters, and stringers) with the ColorLast paint process finish applied.

1. Specify standard color: Classic White, Night Horizon, Moonstone, Flint Smoke, Titanium, Pompeiian Gold, Latte

2. Specify custom color: .

Page 6: · Web viewDesign members to withstand wind loads in accordance with ASCE 710 and applicable code. Design foundations in accordance with applicable code and good construction practices

107056

1.4. ATTACHMENTS

A. Illustrations:1. Width and Projection Orientation Illustration.

2. Component Identification Illustration.

Page 7: · Web viewDesign members to withstand wind loads in accordance with ASCE 710 and applicable code. Design foundations in accordance with applicable code and good construction practices

107056

PART 3 EXECUTION

1.1. EXAMINATION

A. Do not begin installation until supporting structures have been properly prepared.

B. If foundation preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

1.2. PREPARATION

A. Clean component surfaces thoroughly prior to installation.

1.3. INSTALLATION

A. Install in accordance with manufacturer's instructions.

B. Construct foundations in accordance with local codes and good construction practices for the specific structure and site conditions.

** NOTE TO SPECIFIER ** Select the mounting option required from the following paragraphs and delete those not required.

1. Surface Mount on Existing Concrete Slab: Surface mount units on existing concrete slab as indicated in the installation instructions. Concrete shall conform to Section 03300.

2. Surface Mount on New Footings: Surface mount units on new concrete footings as indicated in the on the approved shop drawings. Slab requirements vary according to structure size. Concrete shall conform to Section 03300.

3. Anchor bolts for surface mounted units shall be accurately set using manufacturer’s instructions.

4. Canopy Systems: Install in accordance with manufacturer’s instructions.

1.4. CLEANING

A. Clean all surfaces and restore any marred surfaces to original conditions as approved by the Architect.

1.5. PROTECTION

A. Protect installed products until completion of project.

B. Touchup, repair, or replace damaged products before Substantial Completion.

END OF SECTION