Page 1: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

I-3100-SReprinted 12/1/86

Single Stage Single and Double Vane PumpsV104, 124, 134,144 V109, 129, 139, 149V105, 125, 135, 145 V35*, 36*, 45*, 46*V108, 128, 138, 148 (V)VF-**-**, (V)VG-**-**

Vickers®

Vane Pumps

Overhaul Manual

Page 2: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

2

�Eaton Hydraulics, Incorporated 2000All Rights Reserved

Page 3: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

3

Table of Contents

Section Page

I. Operating Characteristics 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Pump Series – Single Stage 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double Pump Series – Single Stage – Small Series Combination 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

– Single Stage – Intermediate and Small Series 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – Single Stage – Large and Small Series Combinations 5. . . . . . . . . . . . . . . . . . . . . . . . . . – Single Stage – Large and Intermediate Series Combinations 6. . . . . . . . . . . . . . . . . . . .

II. Description 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

III. Principles of Operation 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A. Operation 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B. Lubrication 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C. Routine Inspection and Maintenance 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

IV. Overhaul 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A. General 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B. Disassembly 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C. Reassembly 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D. Product Life 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V. Cartridge Assembly and Installation 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A. Cartridge Assembly 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B. Installation 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C. Head Screw Adjustment 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

VI. Troubleshooting 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

VII. Parts & Illustration Drawings 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 4: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

4

Section I – Operating Characteristics

Type Balanced Vane, Fixed Delivery. . . . . . . . . . . . . . . . . . . Series Single and Double, Single Stage. . . . . . . . . . . . . . . . Operating Pressure See Performance Data. . . . . . . . . . . . . Input Speed, RPM See Performance Data. . . . . . . . . . . . . . Operating Fluid 150 S.S.U. at 100�F. . . . . . . . . . . . . . . . . . Mounting Face, Foot, Flange, Electric Motor End Bell. . . . Connections Pipe Thread Body Ports or Flanges. . . . . . . .

Performance data is based on input speed at 1200 rpm,pumping petroleum base fluid at 120�F. Minimum recom-mended drive speed for all series is 600 rpm. Characteristicsat other drive speeds are approximately proportional to rpm.For performance data when using other than petroleum basefluids, see applicable installation drawing, shown on page 8.

Single Pump Series - Single Stage

V-104-Y-10V-104-E-10V-104-G-10V-104-A-10V-104-C-10V-104-D-10

Head BoltTorque in

lbf. in.Minimum

Model Numbers RecommendedDrive Speed

Delivery, gpm at 1200 r.p.m.

Horsepower Input at 1200r.p.m.

FootMounting

FlangeMounting

maximumrpm

500psi

1000psi

0psi

Small Series

50 lbf. in.

IntermediateSeries

150 lbf. in.

LargeSeries

150 lbf. in.

V-105-Y-10V-105-E-10V-105-G-10V-105-A-10V-105-C-10V-105-D-10

18001800180018001500120015001500150012001200120012001200

V-124-20V-134-20V-134-U-20V-134-X-20V-144-20

V-125-20V-135-20V-135-U-20V-135-X-20V-145-20

1.82.73.75.38.2

11.515.419.523.029.937.941.748.560.6

1.52.43.45.07.9

11.014.518.822.228.9

.539.546.858.3

500psi

1000psi

0psi

VF-40-10V-360-10V-460-10

VG-40-10V-361-10V-461-10

1.12.03.04.77.5

10.613.618.021.327.835.037.245.056.0

.20

.25

.25

.30

.35

.40

.70

.75

.801.001.201.602.002.70

0.91.21.41.92.83.75.86.78.19.7

13.514.016.520.4

1.52.22.63.65.27.0

10.912.414.918.824.126.531.538.4

Double Pump Series – Single Stage – Small Series Combination

V-108-YY-10V-108-YE-10V-108-YG-10V-108-YA-10V-108-YC-10V-108-YD-10V-108-EE-10V-108-EG-10V-108-EA-10V-108-EC-10V-108-ED-10V-108-GG-10V-108-GA-10V-108-GC-10V-108-GD-10V-108-AA-10V-108-AC-10V-108-AD-10V-108-CC-10V-108-CD-10V-108-DD-10

Model Numbers Delivery, gpm Horsepower Input

FootMounting

FlangeMounting

500psi

1000psi

0psi

1.52.43.45.07.9

11.02.43.45.07.9

11.03.45.07.9

11.05.07.9

11.07.9

11.011.0

500psi

1000psi

0psi

1.12.03.04.77.5

10.62.03.04.77.5

10.63.04.77.5

10.64.77.5

10.67.5

10.610.6

.20

.25

.25

.30

.35

.40

.25

.25

.30

.35

.40

.25

.30

.35

.40

.30

.35

.40

.35

.40

.40

0.91.21.41.92.83.71.21.41.92.83.71.41.92.83.71.92.83.72.83.73.7

1.52.22.63.65.27.02.22.63.65.27.02.63.65.27.03.65.27.05.27.07.0

Delivery, gpm Horsepower Input

500psi

1000psi

0psi

1.8 1.5

500psi

1000psi

0psi

1.1 .20 0.9 1.5

V-109-YY-10V-109-YE-10V-109-YG-10V-109-YA-10V-109-YC-10V-109-YD-10V-109-EE-10V-109-EG-10V-109-EA-10V-109-EC-10V-109-ED-10V-109-GG-10V-109-GA-10V-109-GC-10V-109-GD-10V-109-AA-10V-109-AC-10V-109-AD-10V-109-CC-10V-109-CD-10V-109-DD-10

1.82.73.75.38.2

11.52.73.75.38.2

11.53.75.38.2

11.55.38.2

11.58.2

11.511.5

2.7 2.4 2.0 .25 1.2 2.2

3.7 3.4 3.0 .25 1.4 2.6

5.3 5.0 4.7 .30 1.9 3.6

8.2 7.9 7.5 .35 2.8 5.2

11.5 11.0 10.6 .40 3.7 7.0

Small Volume - Head End Pump Large Volume - Shaft End Pump

Page 5: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

5

Double Pump Series – Single Stage – Intermediate and Small Series Combination

V-128-Y-20V-128-E-20V-128-G-20V-128-A-20V-128-C-20V-128-D-20V-138-Y-20V-138-E-20V-138-G-20V-138-A-20V-138-C-20V-138-D-20V-138U-Y-20V-138U-E-20V-138U-G-20V-138U-A-20V-138U-C-20V-138U-D-20V-138X-Y-20V-138X-E-20V-138X-G-20V-138X-A-20V-138X-C-20V-138X-D-20V-148-Y-20V-148-E-20V-148-G-20V-148-A-20V-148-C-20V-148-D-20

Model Numbers Delivery, gpm Horsepower Input

FootMounting

FlangeMounting

500psi

1000psi

0psi

1.52.43.45.07.9

11.01.52.43.45.07.9

11.01.52.43.45.07.9

11.01.52.43.45.07.9

11.01.52.43.45.07.9

11.0

500psi

1000psi

0psi

1.12.03.04.77.5

10.61.12.03.04.77.5

10.61.12.03.04.77.5

10.61.12.03.04.77.5

10.61.12.03.04.77.5

10.6

.20

.25

.25

.30

.35

.40

.20

.25

.25

.30

.35

.40

.20

.25

.25

.30

.35

.40

.20

.25

.25

.30

.35

.40

.20

.25

.25

.30

.35

.40

0.91.21.41.92.83.70.91.21.41.92.83.70.91.21.41.92.83.70.91.21.41.92.83.70.91.21.41.92.83.7

1.52.22.63.65.27.01.52.22.63.65.27.01.52.22.63.65.27.01.52.22.63.65.27.01.52.22.63.65.27.0

Delivery, gpm Horsepower Input

500psi

1000psi

0psi

15.4 14.5

500psi

1000psi

0psi

13.6 .70 5.8 10.9

1.82.73.75.38.2

11.51.82.73.75.38.2

11.51.82.73.75.38.2

11.51.82.73.75.38.2

11.51.82.73.75.38.2

11.5

19.5 18.8 18.0 .75 6.7 12.4

23.0 22.2 21.3 .80 8.1 14.9

V-129-Y-20V-129-E-20V-129-G-20V-129-A-20V-129-C-20V-129-D-20V-139-Y-20V-139-E-20V-139-G-20V-139-A-20V-139-C-20V-139-D-20V-139U-Y-20V-139U-E-20V-139U-G-20V-139U-A-20V-139U-C-20V-139U-D-20V-139X-Y-20V-139X-E-20V-139X-G-20V-139X-A-20V-139X-C-20V-139X-D-20V-149-Y-20V-149-E-20V-149-G-20V-149-A-20V-149-C-20V-149-D-20

37.9 36.5 35.0 1.20 13.5 24.1

29.9 28.9 27.8 1.00 9.7 18.8

Small Volume - Head End Pump Large Volume - Shaft End Pump

Double Pump Series – Single Stage – Large and Small Series Combination

VVF-1-40VVF-2-40VVF-3-40VVF-5-40VVF-8-40VVF-11-40V-368-YV-368-EV-368-GV-368-AV-368-CV-368-DV-468-YV-468-EV-468-GV-468-AV-468-CV-468-D

Model NumbersDelivery, gpm Horsepower Input

FootMounting

FlangeMounting

500psi

1000psi

0psi

1.52.43.45.07.9

11.01.52.43.45.07.9

11.01.52.43.45.07.9

11.0

500psi

1000psi

0psi

1.12.03.04.77.5

10.61.12.03.04.77.5

10.61.12.03.04.77.5

10.6

.20

.25

.25

.30

.35

.40

.20

.25

.25

.30

.35

.40

.20

.25

.25

.30

.35

.40

0.91.21.41.92.83.70.91.21.41.92.83.70.91.21.41.92.83.7

1.52.22.63.65.27.01.52.22.63.65.27.01.52.22.63.65.27.0

Delivery, gpm Horsepower Input

500psi

1000psi

0psi

41.7 39.5

500psi

1000psi

0psi

37.2 1.6 14.0 26.5

1.82.73.75.38.2

11.51.82.73.75.38.2

11.51.82.73.75.38.2

11.5

48.5 46.8 45.0 2.0 16.5 31.5

60.6 58.3 56.0 2.7 20.4 38.4

VVG-1-40VVG-2-40VVG-3-40VVG-5-40VVG-8-40VVG-11-40V-369-YV-369-EV-369-GV-369-AV-369-CV-369-DV-469-YV-469-EV-469-GV-469-AV-469-CV-469-D

Small Volume - Head End Pump Large Volume - Shaft End Pump

Page 6: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

6

Double Pump Series - Single Stage – Large and Intermediate Series Combination

VVSF-14-40VVSF-18-40VVSF-22-40VVSF-28-40VVSF-36-40VVSF-14-48V-350-FTVVSF-22-48V-353-FTV-356-FTVVSF-14-60V-450-FTVVSF-22-60V-453-FTV-456-FT

Model Numbers Delivery, gpm Horsepower Input

FootMounting

FlangeMounting

500psi

1000psi

0psi

14.418.321.928.835.914.418.321.928.835.914.418.321.928.835.9

500psi

1000psi

0psi

13.317.120.827.633.913.317.120.827.633.913.317.120.827.633.9

.70

.75

.851.001.20.70.75.85

1.001.20.70.75.85

1.001.20

5.86.78.19.7

13.55.86.78.19.7

13.55.86.78.19.7

13.5

10.912.414.918.824.110.912.414.918.824.110.912.414.918.824.1

Delivery, gpm Horsepower Input

500psi

1000psi

0psi

41.7 39.5

500psi

1000psi

0psi

37.2 1.6 14.0 26.5

15.419.422.929.937.815.419.422.929.937.815.419.422.929.937.8

48.5 46.8 45.0 2.0 16.5 31.5

60.6 58.3 56.0 2.7 2.0 38.4

VVSG-14-40VVSG-18-40VVSG-22-40VVSG-28-40VVSG-36-40VVSG-14-48V-350-FLVVSG-22-48V-353-FLV-356-FLVVSG-14-60V-450-FLVVSG-22-60V-453-FLV-456-FL

Small Volume - Head End Pump Large Volume - Shaft End Pump

Section II – Description

This manual contains service and maintenance informationfor Vickers single and double pumps. These hydraulicallybalanced cartridge type vane pumps are used to provide aconstant supply of hydraulic fluid under pressure and areproduced in three basic housing sizes: small, intermediateand large. Cartridges of different displacement may be usedinterchangeably in each series. These pumps can be usedas single units or two may be assembled on a common driveshaft (double pump) providing an almost infinite number ofcombinations. Figure 1 illustrates a cross sectional view of aflange mounting, small and intermediate series combinationdouble pump, assembled for left hand rotation.

Figure 1.

Section III – Principles of Operation

A. OperationPumping is performed by cartridges consisting of a ring,rotor, two bushings, twelve vanes and a locating pin orscrews (see Figure 2). The splined pump shaft rotatesdriving a slotted rotor. Vanes within the rotor slots are thrownout by centrifugal force and held out by system pressure tofollow a double lobed cam ring. Movement of the vanes inand out as they follow the cam causes the chambersbetween them to increase in size and pick up fluid from thereservoir as the vanes cross the inlet porting. Chamber sizedecreases when the vanes cross the outlet porting forcingfluid out into the system.

The size of the cartridge ring determines the pumpdisplacement. Ring change alters delivery. However, the 11

gpm ring in the small series and the 36 gpm ring in theintermediate series are used with wide vanes and rotor soconversions to these capacities require additional change ofrotor, vanes and head.

B. LubricationNone is required for current design models. Older designsrequire lubrication of the front shaft bearing. A grease fittingis provided on top of the pump body. (Some of the largerpumps also incorporate a grease relief fitting on the bottomof the body.) It is recommended that these fittings belubricated sparingly (approximately one tablespoonful everysix months) with a low pressure gun using a good quality,high temperature, bearing grease.

Page 7: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

7

CAUTION

Over-lubrication can damage the shaft seal.

C. Routine Inspection andMaintenance 1. Make certain all hydraulic connections are tight to

prevent fluid leakage or entry of air into the system.Completeoverhaul may be accomplished by means of cartridge andgasket kits.

2. Check fluid level in the reservoir to assure anadequate supply to the pump intake. When adding fluid,always pour it through a 200 mesh or finer screen.

3. Inspect the filter element and replace if dirty.

4. Inspect the fluid for contamination. If contaminated,drain the system and thoroughly clean the reservoir. Changethe filters and flush the complete system with new fluid.Again drain the system and refill with new fluid.

5. Check the reservoir air breather and replace if dirty.

D. Product LifeThe longevity of these products is dependent upon environ-ment, duty cycle, operating parameters and system clean-liness. Since these parameters vary from application toapplication, the ultimate user must determine and establishthe periodic maintenance required to maximize life anddetect potential component failure.

Section IV – Overhaul

A. General Complete overhaul may be accomplished by means of car-tridge and gasket kits.

B. Disassembly Disassembly may be accomplished in the order shown in theillustration (Figures 3 or 4).

WARNING

Before breaking a circuit connection, make certainthat power is off and system pressure has beenreleased. Lower all vertical cylinders, dischargeaccumulators, and block any load whose movementcould generate pressure.

Prepare a clean, lint-free surface on which to lay internalparts of the pump. Thoroughly clean areas adjacent to thecomponents being removed to minimize possibility of dirtentering the system. Cap or cover all exposed ports andopenings into the system.

Inspect and replace as follows:

1. Vanes, for wear and sticking in rotor slots. Vanesmust move in slots from their own weight when dry. Replaceif defective. Stone new vanes lightly on an India stone toremove sharp edges.

2. Ring, for scored or cross-grooved cam face. Replaceif grooved or scored.

3. Faces of rotor and bushings for wear and scoring.Remove light scores by lapping; replace if heavily scored.Stone new parts lightly to remove burrs.

4. Bearings for cracked or pitted races or pitted balls.Replace if defective.

5. Shaft for wear at seal lip journal. Replace if scored.

6. Replace shaft seal, O-ring and head packing at eachteardown.

C. Reassembly Assemble parts in reverse order of disassembly, noting the following:

1. Assembly seals with spring toward inside of thepump.

2. Coat all parts with compatible fluid and lightlylubricate the lip of the shaft seal to prevent damage duringinstallation.

3. Install bearing and snap ring on shaft end and placein the body.

4. Spring in the shaft seal must be toward the shaftbearing.

5. Install cartridge parts so arrows on the parts arepointed for intended rotation as viewed from the shaft end.

6. Assemble the pin so its small diameter end fits intothe body for right hand rotation (large end in body for lefthand rotation). See installation page 5.

Page 8: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

8

Section V – Cartridge Assembly and Installation

Figure 2.

The above illustrates the configurations of small and large series pump cartridge parts. Inset view Figure 3, page 7,illustrates configuration of the intermediate series cartridge parts. Assembly procedure is the same.

Assembled for Right Hand Rotation Assembled for Left Hand Rotation

Assembled ViewFacing Head End

Bushing

Ring

Rotor

Bushing

Pin

Bushing

Vane

Ring

Vane

Pin

RotorBushing

A. Cartridge AssemblyFigure 2 illustrates a typical cartridge assembly andinstallation, when viewed from the head end. The cartridgeassembly procedure is the same for both single and doublepumps, depending on the direction of shaft rotation.

The stepped diameter locating pin prevents improper assem-bly of the cartridge. However, caution must be exercised toinstall the cartridge properly for the direction of rotation desired.

The large series pump cartridges have a locating screw and aretaining screw in lieu of the locating pin used in the small andintermediate series.

NOTE

The direction of rotation (right hand or left hand) isalways determined by viewing the pump from theshaft end.

B. InstallationRight Hand Rotation: Insert the small end of the located pininto the small hole in the pump body at a 3 o’clock position.

Left Hand Rotation: Insert the large end of the located pininto the large hole in the pump body at a 6 o’clock position.

C. Head Screw AdjustmentSome pump cover heads and intermediate heads (doublepumps) are provided with two small holes to match the twodiameters of the locating pin. Install the head so the pin fitsthe hole size to prevent the pin from bending or shearingwhen the pump is put into operation.

Pull the head down gradually, alternately tightening thescrews 180� from each other until the head seats evenly onthe bushing. Turn the shaft by hand during the process until alight, smooth snugness is felt through a complete revolution.Do not over-tighten the screws, causing the shaft to bind.

Before starting these pumps, check for freedom of move-ment of the internal parts by turning the shaft by hand. Neverstart a pump which shows evidence of binding.

CAUTION

A new or overhauled pump must be started under loadon the first rum. This will create a back pressure toassure adequate internal lubrication. After a pump isbroken in, it can be started under ’’no-load” conditions.

Page 9: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

9

Start the pump by ”jogging” the drive motor a few times to besure the pump is primed.

If the pump is new or has been overhauled, be certain it is prop-erly installed. Check the direction of shaft rotation and align-ment of the shaft with the drive motor. Since it is difficult toachieve perfect shaft alignment, a flexible coupling must beused.

Exercise care with pumps driven by belts, chain drives, spurgears, etc. to prevent excessive side loading of the drive shaft.Consult your Vickers’ representative for recommendations onthese type drives.

Pump life will be shortened by operation beyond maximumpressure and speed ratings. Since these units are positivedisplacement, a relief valve must be used to limit maximumsystem pressure to recommended limits.

Section VI – Troubleshooting

TROUBLE PROBABLE CAUSE REMEDY

Pump not delivering fluid Pump driven in wrong direction of rotation

Pump drive shaft broken or shaft keysheared (direct drive)

Fluid intake pipe in reservoir blocked or oilviscosity too heavy to pick up primeViscosity should not exceed 4000 S.S.U.

Air leaks at intakePump not primingOil level too low

Vane or vanes stuck in rotor slots

Must be reversed immediately to preventseizure. Check direction of drive rotationagainst proper pump rotation as indicated byarrow on body.Remove pump from accessory mountingpad and determine damage to pump car-tridge. Replace needed parts.Drain complete system. Add new fluid ofproper viscosity. Filter the new fluid as rec-ommended. Check all filters for dirt andsludge.Check intake connection for air leak. Tightensecurely. Loosen connection in outlet line. Bleed-offair until fluid flows.The fluid level must be above intake openingin intake pipe. Check minimum drive speedwhich may be too slow to prime the pumps.Inspect rotor slots for wedged chips or for-eign particles and replace all damagedparts. Flush complete system thoroughly byrecommended processes and fill systemwith new, clean hydraulic fluid.

Pump making noise Partially clogged intake strainer orrestricted intake pipe

Defective bearingAir leak at pump intake piping joints orpump shaft seal

Coupling misalignment

Pump must receive intake fluid freely orcavitation will result. Drain system, cleanintake pipe, and clean or replace strainer.Add new fluid and strain by recommendedprocedures.Disassemble pump and replace bearing.Test by pouring oil on joints and arounddrive shaft. Listen for change in operation.Tighten joints affected. Check pump shaftoil seal for leakage and replace if neces-sary, in accordance with instructions out-lined in this manual. Check shaft for scor-ing at seal contact area and replace shaft ifgrooving is evident.Check shaft bearing and seal for possibledamage. Replace if necessary. Re-alignshafts.

Table 1. Troubleshooting Chart

Page 10: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

10

Section VII – Parts & Illustration Drawings

The intermediate series, current design, cartridge parts areshown in the lower inset view. These modified parts providebetter inlet conditions by reducing wear and excessive noise

due to cavitation. Thus permitting heavier viscosity fluids to beused while improving overall pumps performance.

Intermediate Series Modified Cartridge Parts

Chamfered rotor

Flats on the ring diameter

Notched bushings

Parts are modified as shown to increase the inlet port areas.

1. Head screw2. Head3. Head gasket4. Head bearing5. Cartridge (Includes items 6 thru 11)6. Bushing7. Pin - Locating8. Ring

9. Vane10. Rotor11. Bushing12. Shaft key13. Bracket screw14. Bracket (Foot/Flange)15. Flange gasket16. Drive shaft

17. Snap ring18. Shaft bearing19. Shaft seal20. Spacer21. ”O” (Spacer)22. Body

6

5

4

3

1

15

14

216

17

18

19

20

11

13

12

7 8910

2122

13

Small Series I-3101-S I-138094Intermediate Series I-1630-S I-133744Large Series I-1695-S I-138005

Single Pumps

Pump Size Service Parts Drawings Installation Drawings

Double Pumps

Small Series Combination I-1801-S I-136638Intermediate and Small Series Combination I-1696-S I-135250Large and Small Series Combination I-1800-S I-137475Large and Intermediate Series Combination I-1697-S I-133501

Typical Single Pump Parts & Illustration Drawing

Page 11: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,

11

1. Head screw. 2. Head3. Head gasket4. Cartridge

(Includes items 5 thru 10)5. Bushing6. Pin - locating7. Vane8. Rotor9. Ring

10. Bushing11. Screw12. Lockwasher13. Gasket14. Screw15. Lockwasher16. Mounting Flange17. Gasket

18. Body*19. Flange screw*20. Flange (inlet)*21. Gasket (inlet)*22. Flange screw*23. Flange (outlet)*24. Gasket (outlet)25. Head screw26. Lockwasher27. Head (intermediate)28. Gasket29. Nut30. Lockwasher31. Bearing32. Cartridge

(includes items 33 thru 39)33. Locating screw34. Retaining screw

35. Bushing36. Vane37. Rotor38. Ring39. Bushing40. Shaft key41. Bracket screw42. Bracket

(Foot/Flange)43. Lockwasher44. Flange gasket45. Retainer screw46. Retainer47. Retainer gasket48. Drive shaft49. Lock nut50. Lockwasher51. Bearing

52. Shaft seal53. Seal

(used on basic design only)54. Flange screw55. Flange (Inlet)56. Gasket (inlet)57. Flange screw58. Flange (outlet)59. Gasket (outlet)60. Plug61. Grease fitting

(used on basic design only)62. Grease relief fitting

(used on basic design only)63. Screw64. Rotating plate65. Screw66. Name plate

*Items 19 thru 24 are used on large and inter-mediate double pump combinations. The smallseries used in the large and small combinationshave female pipe threaded ports in the body.

4

15

14

1617

18

1920

1112

29

21

22

13

30

33

3435

37

31

38

36

32

39

60

53

59

57

58

6665

61 63

64

4950

51

6256 55

54

5248

40

47

44

45

46

42

41

43

42

41

25

28

27

262423

10

1 23

5

7

98

6

Typical Double Pump Parts & Illustration Drawing

Page 12: Vickers Vane Pumps - SeekPartfile.seekpart.com/keywordpdf/2011/3/31/20113319839654.pdf · Vickers® Vane Pumps Overhaul Manual. 2 ... Single Pump Series ... Balanced Vane,