2
Aeronautical and Maritime Radiocommunication Systems 40300058 V2.2 VHF DATA BROADCAST EM9009 (A) | RE9009 (A) SERIES 9009 EQUIPMENT This sheet is available on the site www.telerad.fr MAIN FEATURES GBAS VDB Small size, weight and footprint 108.025 - 117.950 MHz frequency band 10 - 80 W RF output power D8PSK, 10500 symbols/s Remote control and maintenance capability EM9009A and RE9009A: AC and DC power supplies EM9009 and RE9009: DC power supply only OVERVIEW The TELERAD VDB system is specifically tailored to meet the VDB LAAS, GBAS and GRAS requirements. The EM9009 Transmitter is designed to broadcast the GPS Correction data whereas the RE9009 Receiver permits to monitor the VDB signal in space. EM9009 TRANSMITTER 80 W RF output power Low power consumption High reliability Outstanding ACP performance RE9009 RECEIVER VDB monitoring receiver Outstanding sensitivity and cositing, performance High reliability

VHF DATA BROADCAST - TeleradA R S 0000 VHF DATA BROADCAST EM9009 (A) | RE9009 (A) SERIES 9009 EQUIPMENT This sheet is available on the site main feaTures GBas VDB small size, weight

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • Aeronautical and Maritime Radiocommunication Systems

    40300058 V2.2

    VHF DATABROADCAST

    EM9009 (A) | RE9009 (A)

    SERIES 9009 EQUIPMENT

    This sheet is available on the site www.telerad.fr

    main feaTures

    GBas VDB small size, weight and footprint 108.025 - 117.950 mHz frequency band 10 - 80 W rf output power D8PsK, 10500 symbols/s remote control and maintenance capability em9009a and re9009a: aC and DC power supplies em9009 and re9009: DC power supply only

    OVerVieW

    The TELERAD VDB system is specifically tailored to meet the VDB Laas, GBas and Gras requirements. The em9009 Transmitter is designed to broadcast the GPs Correction data whereas the re9009 receiver permits to monitor the VDB signal in space.

    em9009 TransmiTTer

    80 W rf output power Low power consumption High reliability Outstanding aCP performance

    re9009 reCeiVer

    VDB monitoring receiver Outstanding sensitivity and cositing,

    performance High reliability

  • 2, avenue de la Butte aux Cailles - BP 302 - 64 603 anGLeT CeDeX - franCe Tel.: +33 (0)5 59 58 55 00 - fax: +33 (0)5 59 58 55 01 - email: [email protected] contractual document

    SERIES 9009 EQUIPMENT

    em9009 (a) TransmiTTerMechanical characteristics:

    Width: 19 in (483 mm) Overall depth: 17 in (430 mm) Height: 5.2 in (132 mm), 3u Weight: < 31 ibs (14 kg)

    Power consumption (80 W average output power): 24 VDC: 14 a (Typ.) 230 VaC: 2.2 a (Typ.)

    RF output power:10-80 W in 0.5 dB stepsVSWR:up to a VsWr of 2:1 without power reductionProtections:Power reduction on overheating and high VsWrDuty cycle:100 %Modulation:D8PSK - raised cosine filter (∞ = 0.6)Symbol rate:10500 symbols/s + 50 ppmSymbol constellation error:< 6.5 % rmsUnwanted emissions:< -53 dBmAdjacent channel power :

    1st channel < -40 dBc (25 kHz) 2nd channel < -65 dBc (25 kHz) 4th channel < -74 dBc (25 kHz)

    Emissions in unassigned time slot:< -105 dBc (25 kHz)

    re9009 (a) reCeiVerMechanical characteristics:

    Width: 19 in (483 mm) Overall depth: 17 in (430 mm) Height: 1.75 in (44.5 mm), 1u Weight: < 9 ibs (< 4 kg)

    Power consumption: 24 VDC: 500 ma (Typ.) 230 VaC: 180 ma (Typ.)

    Sensitivity and dynamic range:Ber < 10-4 or mfr < 1/1000 over the dynamic range from -87 dBm to -1 dBmAdjacent channel rejection:> 50 dBSymbol capture range:10500 symbols/s + 50 ppmFrequency capture range:± 1 kHzCo-channel interference:mfr < 1/1000 in the presence of an undesired cochannel VDB signal that is:

    assigned to the same time slot(s) and 26 dB below the desired VDB signal

    assigned different time slot(s) and whose is up to 15 dBm

    3rd order intermodulation:iP3 > +5 dBm

    GeneraL DaTaFrequency range:108.025-117.950 mHzFrequency stability:≤ 1 ppmChannel spacing:25 kHzModulation:

    14K0G7D D8PsK 10500 symbols/s

    Power supply:em9009 and re9009: 24 VDC (21-31 V)em9009a and re9009a:

    Primary power: 230/115 VaC secondary power: 24 VDC (21-31 V) automatic switchover aC-to-DC

    Temperature: Operating: -20 °C to +55 °C relative humidity: 95 % at 40 °C (non-condensing) storage: -40 °C to +80 °C

    Data interface:rs485 up to 115.2 KbpsTime mark:rs485 input for 1 PPsMaintenance:

    Local (rs232) or remote (rs485) maintenance: BiT, software loading setup functions: frequency, operation, parameters measurements: Tx output power, VsWr, DC voltage, rx

    aGC voltage...Standards:

    iCaO sarPs eurOCae eD-114 rTCa DO-178B