Vetting Obs List

Embed Size (px)

Citation preview

CB CB CB CB CB CB CB NEW BARCEL GIBRALT HONGKO HOUSTO CB KOBE SAVANN SHANGH YORK ONA AR NG N AH AI

CB ULSAN

CB VIRGIN GODA

CB CB NEW YOKOHA ORLEAN MA S

Date

15-Jan-091

15-Jan-09

15-Jan-09

1

28-Jan-09 28-Jan-09

28-Jan-09

28-Jan-09

28-Jan-09

28-Jan-09 28-Jan-09

28-Jan-09

28-Jan-09

28-Jan-09 28-Jan-09 28-Jan-09

10-Feb-091

10-Feb-09

10-Feb-09

10-Feb-09 10-Feb-09 10-Feb-09 10-Feb-09 10-Feb-09

10-Feb-09 10-Feb-09

22-Jan-091

22-Jan-09

22-Jan-09

24-Feb-091

24-Feb-09 24-Feb-09 24-Feb-09 24-Feb-09 24-Feb-09 24-Feb-09 24-Feb-09

1

23-Feb-09 23-Feb-09 23-Feb-09

23-Feb-09

23-Feb-09 23-Feb-09 23-Feb-09 23-Feb-09 23-Feb-09

23-Feb-09 23-Feb-09 23-Feb-09 23-Feb-09 23-Feb-09

1

3/4/2009

3/4/2009

3/4/2009

3/4/2009 3/4/2009 3/4/2009

3/4/2009

3/4/2009 3/4/2009

1

12-Mar-09 12-Mar-09 12-Mar-09 12-Mar-09 12-Mar-09 12-Mar-09 12-Mar-09 12-Mar-09 12-Mar-09

15-Mar-091

15-Mar-09

15-Mar-09

15-Mar-09

15-Mar-09

15-Mar-09

15-Mar-09

15-Mar-09

15-Mar-09

15-Mar-09

15-Mar-09

31-Mar-091

31-Mar-09 31-Mar-09

31-Mar-09

31-Mar-09

31-Mar-09

31-Mar-09 31-Mar-09 31-Mar-09 31-Mar-09 31-Mar-09 31-Mar-09 31-Mar-09 31-Mar-09 31-Mar-09

31-Mar-09

31-Mar-09 31-Mar-09

31-Mar-09

31-Mar-09 31-Mar-09

31-Mar-09

31-Mar-09 31-Mar-09 31-Mar-09

31-Mar-09

31-Mar-09

1

31-Mar-09 31-Mar-09

31-Mar-09

31-Mar-09

31-Mar-09

31-Mar-09 31-Mar-09 31-Mar-09

31-Mar-09 31-Mar-09 31-Mar-09 31-Mar-09 31-Mar-09 31-Mar-09

17/04/20091

17/04/2009

17/04/2009

17/04/2009

17/04/2009

17/04/2009 17/04/2009

17/04/2009 17/04/2009 17/04/2009

17/04/2009

22-Apr-091

22-Apr-09 22-Apr-09 22-Apr-09

22-Apr-09

22-Apr-09 22-Apr-09

22-Apr-09

1

7-May-09 7-May-09 7-May-09 7-May-09

7-May-09

7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09 7-May-09

7-May-09

7-May-09 7-May-09 7-May-09 8-Jun-09 8-Jun-09 8-Jun-09 8-Jun-09 8-Jun-09 8-Jun-09 8-Jun-09 8-Jun-09

1

1

11-May-09 11-May-09 11-May-09 11-May-09 11-May-09

11-May-09

11-May-09 11-May-09 11-May-09 11-May-09 11-May-09 11-May-09 11-May-09 11-May-09

11-May-09

11-May-09

11-May-09

1

5/26/2009

5/26/2009

5/26/2009

5/26/2009

5/26/2009 5/26/2009 5/26/2009

5/26/2009

5/26/2009

5/26/20091

6/4/2009 6/4/2009 6/4/2009 6/4/2009 6/4/2009

6/4/2009 6/4/2009 6/4/2009

6/4/2009 6/4/2009 6/4/2009 6/4/2009

1

6/4/2009 6/4/2009 6/4/2009

1

6/2/2009 6/2/2009

6/2/2009 6/2/20096/9/2009

1

6/9/2009 6/9/2009 6/9/2009 6/9/2009 6/9/2009 6/9/2009 6/9/2009

1

06-22-2009

06-22-2009 06-22-2009 06-22-2009 06-22-2009 06-22-2009

06-22-2009 06-22-2009 2 3 1 1 1 2 2 2 2 3 1 2 Total

Year

Month

Oil Major

Inspector

Location

Chapter

SubChap

CDI No.

Description

2009

Jan

SHELL

Rotterdam

5

2

2009

Jan

SHELL

Rotterdam

5

6

2009

Jan

SHELL Capt Andrew Lott Capt Andrew Lott

Rotterdam Vancouver, Canada Vancouver, Canada

5

8

There was no documentary evidence available the masters review of the Safety management system was carried out. Only one line remark in the master handover documen There was no proper procedure in place for reporting/investigation of accident, incidents, non-conformities and near misses. No near miss had been reported throughout last two years Smoking regulations not adhered to as ships personnel seen smoking in the wheelhouse.There was no records of any thickness gauging onboard the vessel. The vessel was not recording the radar PM tests once per watch the onboard TM Master system required this every 3 months The vessel frequently conducted welding operations away from the ER workshop but they did not have an extended return cable as per ISGOTT 9.5. The ground remained conneccted adjacent to the welding unit in the ER workshop. The vessel was not making the weekly "movement of the lifeboats from stowed position" or inspections of the on load release systems as required by solas. The lifebuoy on the stbd maindeck area (located ontop of deck house) was obstructed with a security station - rectified when noted The firemans outfits were in poor condition with the reflective material missing in large areas - the ship reported that replacements had been ordered. Visual inspection of the ballast surface required the removal of a large bolted cover plate. The overfill alarm of 2P cargo tank was not operational. The pressure sensors for 1P, 1S, 5S & 7S Cargo tanks were not operational. It was reported that spare parts were on order to rectify these items The policy called for samples to be sent every 3 months, the last samples were sent 30 Aug 2008. The vessel did not currently have the required containers onboard to draw and submit samples. The 100V circuit was found with low resistance - the meter was indicating 0.5MOhm. The gyro repeater in the steering flat was not correctly aligned with the ships head - rectified during inspection. The operator did not issue formal guidelines for conducting WWT. The only reference the vessel had was in the tank cleaning guide but this did not address required PPE. As per the DNV class status report downloaded on 04 February 2009 vessel has out standing memoranda MO 2, issued on 11 June 2008 'IAPP certificate, change over procedure to low sulphur FO to be prepared and filled on board before entering SECA zone. Publication (2.24.18)Mooring Equipment Guidelines, 3rd Edition, (2.24.24) IMDG Code vol 1, 2 and Supplement and (2.24.25) USCG CFR 33 Parts 1 - 199 regulations for tanker, 2008 edition was not on board. As per operator procedure master to issue letter at the time of sign off giving the list of chemicals carried during the tenure of officer and crew, basis that chemical specific medical check to be carried out. For most of officer and crew there was no report or other evidence to show that test is actually being carried out. 1) Admiralty list of Light Volume F (NP 79) published on 13 November 2008 used during last voyage was not on board. 2) Admiralty chart catalogue 2009 edition was not on board Chief Officer was designated as safety officer, he has not received the appropriate training. Calibration gas for H2S and LEL 50% for portable and personal gas meter was not on board. No air quality test certificate for SCBA compressor was sighted. No acknowledgement of the MF / HF periodical test with shore station was sighted.

2009

Jan Jan

BP BP

2 4

18 3

2009

2009

Jan

BP

Capt Andrew Lott

Vancouver, Canada

5

38

2009

Jan

BP

Capt Andrew Lott Capt Andrew Lott Capt Andrew Lott Capt Andrew Lott Capt Andrew Lott

Vancouver, Canada Vancouver, Canada Vancouver, Canada Vancouver, Canada Vancouver, Canada

5

44

2009

Jan

BP

5

53

2009

Jan Jan

BP BP

5 6

70 31

2009

2009

Jan

BP

8

40

2009

Jan

BP

Capt Andrew Lott Capt Andrew Lott Capt Andrew Lott Capt Andrew Lott

Vancouver, Canada Vancouver, Canada Vancouver, Canada Vancouver, Canada

11

11

2009 2009

Jan Jan Jan

BP BP BP

11 11 8

46 51 36

2009

2009

Feb

BP

Capt Sanjay Sinha

Mundra, India

2

15

2009

Feb

BP

Capt Sanjay Sinha

Mundra, India

2

24

2009

Feb

BP

Capt Sanjay Sinha

Mundra, India

3

9

2009

Feb Feb Feb Feb Feb

BP BP BP BP BP

Capt Sanjay Sinha Capt Sanjay Sinha Capt Sanjay Sinha Capt Sanjay Sinha Capt Sanjay Sinha

Mundra, India Mundra, India Mundra, India Mundra, India Mundra, India

4 3 5 5 10

16 1 34 71 8

2009 2009 2009 2009

2009 2009

Feb Feb

BP BP

Capt Sanjay Sinha Capt Sanjay Sinha

Mundra, India Mundra, India

11 9

25 2

No oil mist detector was fitted for the hysraulic aggregate pump located in engine room. Vessel using 17 poly propylene mooring ropes. The master's review of the safety management system, which was completed at the time of handover was not specific in sections reviewed One sludge tank designated in Form B of the IOPP Certificate - M.E. Air Cooler Tank, was not listed in the Oil Record Book Part 1. Segregated ballast could not be easily checked visually as numerous bolts had to be removed to open the manhole cover. Ballast water was sampled by dipping tanks through It was noted that the vessel was using persons signed on as cadets in roles as watchkeeping ratings both in ER and on bridge The vol G of the BA ALLS had been subject of a new edition Nov 2008 but this new editions had not yet been received onboard During the pilotage to this berth the position had been plotted using GPS only. The port state control deficiencies issued during a PSC inspection Nov 2008 had not been issued as NCR's There was an old pump casing noted on the 3rd level in engineroom that was not secured against movement Visual inspection of the ballast surface required the removal of a large bolted cover plate The GMDSS log was not being maintained as per the instructions in the front of the book. The loadline was still marked with the old class society markings, ie marked with NK, not NV. Vessel has two oustanding memeoranda re missing documents Unannounced drug test was last carried out on 15 January 2007, more than 24 month. As per the operator procedure unannounced drug test to be carried out once in 12 month No record last calibration of the alcohol meter on board was sighted. As per the operator procedure Master to issue the list of chemical carried during the tenure of officer / crew based on that chemical specific test to be carried out after sigh off. No officer / crew had any test report after sign off from last chemical taner under the same operator. Time and position of alteration of course was not being entered in deck log book or GPS log. Admiralty chart catalogue 2009 edition was not on board. Vessel bow thruster was not in operation. Chief officer was designated as safety officer, he has not received appropritae training. SCBA compressor air quality test certificate was simply stating test found satisfactory, no detail of test being carried was mentioned Cargo operation did not have the details of th ullage and cargo handling sequence and intermediate stress conditions were not being calculated. Forward draft gauge was not working. Gas tight chemical suite hand rubber was damaged . Drum under the brake lining was rusted and had minor pitting. White correction fluid was being used in engine room log book, numerous overwriting was observed in engine room log book.1-1-14 Certificate of compliance expired 5 Feb 2009 The vessel has one condition related to class - CA 602 - before due date the LRIT system to be tested (due date April 16.2009) CDI inspector observed above test completed and certified by MPA on the 24.Jan.2009 - ship awaiting class to delete . Memo to owners observed: Following document required in connection with Class entry Missing Addendum to intact stability information for increased draught of 12.00 M Working hrs for Ch Engineer and 1t Engineer not recorded when they have attended stand by and maneuvering on the 3rd and 25/26 Feb 2009.

2009

Jan

BP

Shanghai

2

5

2009

Jan

BP

Shanghai

6

2

2009

Jan

BP

Shanghai

6

31

2009

Feb

BP

Andrew Lott

Vancouver

3

1

2009

Feb Feb Feb Feb Feb Feb Feb

BP BP BP BP BP BP BP

Andrew Lott Andrew Lott Andrew Lott Andrew Lott Andrew Lott Andrew Lott Andrew Lott

Vancouver Vancouver Vancouver Vancouver Vancouver Vancouver Vancouver

4 4 5 5 6 10 12

6 20 6 11 31 9 3

2009 2009 2009 2009 2009 2009

2009

CHEVRON CHEVRON CHEVRON

S.Sinha S.Sinha S.Sinha

Mundra Mundra Mundra

2 3 3

16 16 11

2009

2009

2009

CHEVRON

S.Sinha

Mundra

3

9

2009 2009 2009 2009

CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON

S.Sinha S.Sinha S.Sinha S.Sinha S.Sinha

Mundra Mundra Mundra Mundra Mundra

4 4 9 5 5

3 16 26 1 71

2009

2009 2009 2009 2009

CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON

S.Sinha S.Sinha S.Sinha S.Sinha S.Sinha

Mundra Mundra Mundra Mundra Mundra

8 8 8 9 11

24 40 84 13 9

2009

2009

Mar

CDI

Antofgasta

2009

Mar

CDI

Antofgasta1-5-12

2009

Mar

CDI

Antofgasta2-1-13

2009 2009 2009

Mar Mar Mar Mar

CDI CDI CDI CDI

Antofgasta Antofgasta Antofgasta Antofgasta

3-1-46 4-1-7 5-1-14

2009

6-1-13 2009 2009

Mar Mar

CDI CDI

Antofgasta6-3-1

Antofgasta

9-1-23

The ship is not fitted with an Electronic Chart Display System The ship is not fitted with self storing mooring winches The approved cargo computer system has no Damage stability assessment The list of spare parts in ship computer based PMS not fully up to date. Emergency generator spare not listed . Doing random test on engine spares stock -one of 2 items was not located. in the T M Master. (Computer) The main switch board for 220 V showing an earth fault over 3 meg ohm - working on/off on deck light showing earth fault is related to deck working light or cabling. Fire station 1 - Observer 2 fire suites (aluminum type) with broken coating under the armpits.

2009 2009 2009 2009 2009 2009 2009 2009 2009

Mar Mar Mar Mar Mar Mar Mar Mar Mar

CDI CDI CDI CDI CDI CDI CDI CDI CDI

STENSBERG STENSBERG STENSBERG STENSBERG STENSBERG STENSBERG STENSBERG STENSBERG STENSBERG

BALBOA BALBOA BALBOA BALBOA BALBOA BALBOA BALBOA BALBOA BALBOA

1-1-21 1-1-28 1-3-24 1-4-4 3-1-7 3-1-32 3-1-56 4-1-2 5-3-17

The engine room crane and stores crane were not included in the last annual test The ship was not in possession of an "ELAPPC" certificate, the ship's keel was laid october 29th 2000 3rd/eng not in possession of flag state acceptance In the GMDSS radio log no record over training of persons to send distress alerts Inspection rounds are not udertaken after the watches and reported to the bridge Exchange procedures for the master to assume control from the duty officer are not clearly recorded The ship is not fitted with a LRIT system Not all mooring ropes were turned up on the bitts correctly The fixed remor reading temperature system was not calibration checked within the last 12 months The fire operational booklet does not contain procedures for caego tank gas freeing and purging as required by SOLAS ChII-2, part E, reg 16.3.2 Mooring equipment guidelines (OCIMF)- The latest edition of the publication is not onboard, however, evidence was provided that the publication was to be sent to the vessel in the next mail The latest internal audit was carried out 9 Feb 2009 and only the non-conformances identified were left on board, no internal audit report on board at the time of the inspetction The company subscribed to a supplier for nautical chart and publications. On checking All VolF, the edition was last corrected up to week 46/08, when a new edition was published. Corrections for new edition have been kept and the vessel is still awaiting the delivery of the new edition. This edition is in the next mail delivery to the vessel. The windlass gypsy gear and drive gear teech were all dry and no sign of recent greasing The repetative checks section of the ship SSSCL was found to be signed for 0700 and 0800 15th March although at the time of the inspection it was only 0630 in the morning of 15th March Although the present cargo discharge plan had been signed by all OOW, the time and date of this meeting and discussion of the plan was not recorded The vessel has three portable thermometers but there are no records of calibration of these against the reference thermometer on board The hydraulic aggregates for the cargo and mooring systems are located in the ER which is a skid arrangement provided with a leak detector inside a sealed cabinet. However, the high pressure piping passes within the ER before passing through the ER bulkheads to the deck are and there is no Oil Mist Detector in the civinnity to provide protection in the event of a leak in joints or piping In the dedicated food bin in the garbage storage area, the food waste was found to be kept in a plastic bag The required period for unannounced Drug and Alcohol testing by an external body is set out in the company Drug and Alcohol Policy Manual as 12 months. The last recorded test by an external body available on board was done 2 novernber 2007 The Master had not attended a ship handling course. However, he stated that he was scheduled to attend one during his coming leave.

2009

Mar

CDI

John Bussell

Singapore

1-2-1

2009

Mar

CDI

John Bussell

Singapore

1-2-13

2009

Mar

CDI

John Bussell

Singapore

2-1-24

2009

Mar

CDI

John Bussell

Singapore

3-1-52

2009

Mar

CDI

John Bussell

Singapore

4-1-13

2009

Mar

CDI

John Bussell

Singapore

5-1-2

2009

Mar

CDI

John Bussell

Singapore

5-1-21

2009

Mar

CDI

John Bussell

Singapore

5-3-15

2009

Mar

CDI

John Bussell

Singapore

6-3-1

2009

Mar

CDI

John Bussell

Singapore

11-1-20

2009

Mar

CDI

John Bussell

Singapore

8-1-48

2009

Mar

CDI

GRAHAM C. BELSON

Rotterdam

3

1-3-22

2009

Mar Mar

CDI CDI

GRAHAM C. BELSON GRAHAM C. BELSON

Rotterdam Rotterdam

4 4

3-1-15 3-1-17

Navigation warnings relevant to the English Channel area the vessel had just transited should have been charted but had not been. Only the GPS was used for position fixing deep sea The system for maintaining navigation warnings was very poor, and out of date notices were stored with current. This made it extremely difficult to determine which warnings were relevant to the current voyage. There was also no system in place for the officer of the watch to acknowledge each warning whilst on watch, nor to record which warnings were charted on which charts. Moorings ropes had been made fast on bitts without a round turn on the leading post. The winche brake screws had been fitted with collars, inteneded to mark the amount of tension to apply, but which prevented the brake being tightened further than the collars. The 3rd edition of MEG refers to this and suggests that it is not good practice The aft emergency towing wire pendant was in very poor condition. The interval for the repetitive checks has been set to 24 hours. The loading computer programme did not include damaged stability. The ballast pump drive shaft guard did not adequately cover the moving parts. 2P level gauge was not operational 2P temperature measurement system was not operational. 2P pressure measurement system was not operational. The Company did not provide guidance on the care and maintenance of the tank cleaning equipment. 2P high level alarm system was not operational. 2P high / high level alarm system was not operational A brief review of the planned maintenance system revealed that several maintenance items were overdue - auxiliary engine no. 1: an inspection of the main bearings was overdue by over 2600 hours, and the renewal of bearings on no. 3 auxiliary engine was overdue by over 4000 hours. The Chief Engineer could not state whether or not the company were aware of this, or the reason for the items being overdue. There were no records of the regular inspection of small lifting gear. There were no Company procedures for reporting maintenance non conformity. The emergency generator exhaust was in very poor condition. It had been coated with tape of some sort, but this had also deteriorated and in places the exhaust pipe had collapsed Store rooms - Heavy equipment - cooler covers - were not satisfactorily secured in the accommodation below the provisions hatch. There were no records of the monitoring of spaces with a potential for the build up of flammable or toxic vapours The self igniting light with the pilot ladder lifebuoy was not 'Ex' rated. However, an attempt had been made recently to purchase one and an incorrect type had been supplied. The Master stated that another would be ordered The cylinder of one of the chemical protective equipment BA sets was under charged Several cylinders of firemen's outfit BA sets were undercharged. The ropes securing the smoke floats to the bridge wing lifebuoys were in poor condition. Recent entries in the ORB part I with respect of the disposal of slops were very poorly defined and it was not possible to determine exactily what has taken place. However it was likely that this was simply clerical errors rather than any infringiment of Marpol

2009

2009

Mar

CDI

GRAHAM C. BELSON

Rotterdam

4

3-1-28

2009

Mar

CDI

GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON

Rotterdam

9

4-1-2

2009

Mar

CDI

Rotterdam

9

4-1-12

2009 2009 2009 2009 2009 2009 2009 2009 2009

Mar Mar Mar Mar Mar Mar Mar Mar Mar

CDI CDI CDI CDI CDI CDI CDI CDI CDI

Rotterdam Rotterdam Rotterdam Rotterdam Rotterdam Rotterdam Rotterdam Rotterdam Rotterdam

9 5 8 7 8 8 8 5 8

4-1-26 5-1-2 5-1-14 5-1-50 5-3-6 5-3-11 5-3-18 5-3-48 5-4-5

2009

Mar

CDI

GRAHAM C. BELSON

Rotterdam

11

6-1-12

2009 2009

MarMar

CDI CDI

GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON

RotterdamRotterdam

55

6-1-166-2-23

2009

Mar

CDI

Rotterdam

11

6-3-1

2009

Mar Mar

CDI CDI

Rotterdam Rotterdam

11 8

6-4-1 8-1-33

2009

2009 Mar 2009 2009 2009

CDI

Rotterdam

4

8-1-44

Mar Mar Mar

CDI CDI CDI

GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON GRAHAM C. BELSON

Rotterdam Rotterdam Rotterdam

6 6 12

8-2-7 9-1-7 10-1-25

2009

Mar

CDI

Rotterdam

5

11-1-7

2009

Mar

CDI

Rotterdam

5

11-1-20 Several garbage containers were made of plastic.

2009 2009

Mar Mar

BP BP

Sanjay Sinha Sanjay Sinha

JNPT JNPT

2 2

1 24

COC for anti fouling paint used during last dry-dock in July 2007 was not sighted on board Publication (2.24.17) guide to helicoptor/ ship operation latest edition was not on board As per operation procedure master to issue letter at the time of sign off giving the list of chemicals carried during the tenure of officer and crew, basis that chemical specific medical check to be carried out. For most of officer and crew there was no report or other evidence to show that test is actually being carried out T & P notices of the B.A charid used during the last voyage were not fully updated. VDR last pierfonnance test was carried out on Il July 2007 more than 20 months. During the last repair carried out on 09 Sept 2008 final remark Unable to erase DVD rains, either RAM or drive faulty, no spare DVD RAM availablc. unable to connect n ith the software maintenance to RCV no suitable cable available. Life rafts ritve last serviced on 23 March 2008, more than 12 month. Vessel stayed in anchor in last 2 port for more than a week each. Escape suthe air bottles were last hydrostatic pressure tested in December 2003, more than 5 years. Manifold sjpill container were not sub divided for the dangers associated with commingling of non compatible cargoes. Sample lociker was not suitabely cell divided for the dangers associated with the cargoes vessel is certified to carry e.g. acids. Seal of no II hydraulic driven water ballast pump in ballast pump room had minor leak. Drum un&r the brake lining were rusted anf had pitting. No oil mist detector was fitted for the hydraulic aggregate pump located with main engine compartment. High pressure fuel oil pump of no 1 & 3 unit of main engine had minor leak. Steam inlet and return Ithe going to cargo tank from aft of marufold till forward was corroded. Safety management system of a computer based electronic version was unable to use as all PCs were influenced by virus since end of Mar 2009. The log was not updated daily and all logs were completed only up to 31 Mar 2009. The log for Mar 2009 was randomly checked, found all engineers' logs did not reflect working hours when the engine room was stand-by for arrival & departure and the C/O's log did not include his working hours between 0100 - 0600hrs on 21 Mar 09 when cargo hoses were being connected and loading was commenced. As per a radar log, performance monitor was carried out by each OOW but was just of resulted as Good other than actual figure reading. At random checks, three chart no. 3183, 3186 & 3192 for this port were partly worn out and partly taped along folded line. Water depth along Houston ship channel was incorrectly recorded to calculate UKC, it was written to 10.06 meter other than 45 feet and resulted static UKC only 0.36 meter where ship's speed was maintained about 10 knots of which squat affected sinkage was about 1 meter as per displayed squat table. No parallel index was marked on the Galveston approaching chart. High and low pressure alarm was set at 20Kpa and - 6.0Kpa while working pressure setting on individual high velocity P/V vents was 0.20Kpa & -3.5Kpa. Three mooring ropes on f'cle deck were made fast to bitts without one round turn on leading post before making a figure of 8. Last weekly test recorded was dated to 29 Mar 2009. Though the E/R was certified for UMS, the space has been manned under the operator's policy.

2009

Mar

BP

Sanjay Sinha

JNPT

3

9

2009

Mar

BP

Sanjay Sinha

JNPT

4

14

2009

Mar

BP

Sanjay Sinha

JNPT

4

26

2009

Mar Mar Mar

BP BP BP

Sanjay Sinha Sanjay Sinha Sanjay Sinha

JNPT JNPT JNPT

5 5 8

50 70 28

2009

2009

2009

Mar Mar Mar Mar Mar Mar

BP BP BP BP BP BP

Sanjay Sinha Sanjay Sinha Sanjay Sinha Sanjay Sinha Sanjay Sinha Sanjay Sinha

JNPT JNPT JNPT JNPT JNPT JNPT

8 8 9 11 11 12

38 40 15 25 40 6

2009 2009 2009 2009 2009

2009

Apr

BP

PYONG IN CHONG

HOUSTON

2

2

2009

Apr

BP

PYONG IN CHONG

HOUSTON

3

3

2009

Apr

BP

PYONG IN CHONG PYONG IN CHONG

HOUSTON

4

5

2009

Apr

BP

HOUSTON

4

13

2009

Apr

BP

PYONG IN CHONG

HOUSTON

4

20

2009

Apr Apr

BP BP

PYONG IN CHONG PYONG IN CHONG PYONG IN CHONG PYONG IN CHONG PYONG IN CHONG

HOUSTON HOUSTON

4 8

22 56

2009

2009

Apr Apr Apr

BP BP BP

HOUSTON HOUSTON HOUSTON

9 10 11

7 8 3

2009 2009

2009

Apr

BP

PYONG IN CHONG

HOUSTON

11

25

Hydraulic power packs are located at open deck in engine room without oil mist detection system. Operator's emergency procedures listed under 0180 in safety manual did not contain specific procedure for "rescure from enclosed spaces" C/O has been designated as Ship Safety Officer. He was reportedly trained for his role but no evidence existed to support it Safety Equipment Certificate- Item5.2 status did not reflect fitted SVDR equipment on board Passage plan did not contain information about navtex status. Correct stations were selected for trading area but no reference made in passage plan Section of company shipboard manual (Officer of the watch under 0040) required position fix interval to be 15 minutes in coastal waters. Vessel passed 6 miles off the Hartsholm ( NW Denmark) with speed of 14 knots and position fix noted every 30 minutes ( BA charts 1422 and 1402).Passage plan form for that stage /charts required only 30 minutes fix interval as well. All engine compliment accompanied inspector during engine room tour wearing no ear protection. C/O was not familiar with P/V valves designed pressure settings. He was able to locate the required info in manual during this inspection. Deck storehouse located on port side forward of manifold platform had no light fitted inside the space. This space was used for general deck equipment, cargo reducers, cleaning equipments etc. and was frequently entered during night time. There was no evidence that the Safety officer (Chief Officer) had received appropriate training for this role The GMDSS log had not been completed to STCW 95 requirements in that pre-departure checks of equipment had not been recorded The master had not completed the bridge order book for every night when the vessel was at seaThe bow thruster was not operational The aft towing wire was not deployed to the stern lead but was accessible through a hatch to the towing drum which was located in a store on the poop. Deploying the wire from this location would foul the attached collar of the wire with a bracket to a deadman fairlead about one metre aft of it so the aft towing wire was not ready for immediate use The approved stability computer did not include damage stability assessment There was no record of the calibration checks of the fixed pressure gauge against the reference manometer within the last 12 months There was no record of the calibration checks of the fixed tank pressure gauging system within the last 12 months No procedure was sighted for the actual disposal of samples A solenoid leak in the hydraulic system in the aft port side of the focstle had caused pooled hydraulic oil beneath the solenoid and in the bilge well (which contained fibrous material) and the aftermost angle of the focstle (oil since cleaned up) One hammer in the engine room workshop had been welded to its metal shaft Generic smoking notices did not reflect the shore permitted locations (5 against 3) this port and no port specific smoking notices were posted On the enclosed space entry permits, the toxic gas being tested for was not specified No permits were sighted for work on electircal circuits There was no first aid kit available in the medicine locker ready for swift transfer to the site of an accident No procedures were sighted covering the use of Oxygen detectors for personal use No procedures were sighted covering the use of gas detection No Company safety procedures were sighted for the use of deck cranes No Company safety procedures were sighted for avoiding slips and falls No Company safety procedures were sighted for securing walkways The gangway net was wrapped round the stanchions rather than being spread (since rectified)

2009

APR

SHELL

AMESTERD AM AMESTERD AM AMESTERD AM AMESTERD AM

2

2

2009

APR APR APR

SHELL SHELL SHELL

5 2 4

1 1 20

2009

2009

2009

APR

SHELL

AMESTERD AM

4

21

2009

APR APR

SHELL SHELL

AMESTERD AM AMESTERD AM

5 8

3 13

2009

2009

APR

SHELL

AMESTERD AM

12

15

2009

MAY MAY MAY MAY

CDI CDI CDI CDI

1-3 1-4-4 3-1-9 3-1-58

2009

2009 2009

2009

MAY

CDI

4-1-26

2009 2009 2009 2009 2009

MAY MAY MAY MAY MAY MAY MAY MAY MAY MAY MAY MAY MAY MAY MAY MAY

CDI CDI CDI CDI CDI CDI CDI CDI CDI CDI CDI CDI CDI CDI CDI CDI

5-1-14 5-3-22 5-3-24 5-3-55 5-4-3 6-3-1 7-1-10 7-1-17 7-1-21 8-1-16 8-1-30 8-1-32 8-1-38 8-1-39 8-1-40 8-1-46

2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009

2009

MAY

CDI

2009 2009 2009

MAY MAY MAY June June June June June June June June

CDI CDI CDI CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON F. PIZARRO F. PIZARRO F. PIZARRO F. PIZARRO F. PIZARRO F. PIZARRO F. PIZARRO F. PIZARRO Mejillones Mejillones Mejillones Mejillones Mejillones Mejillones Mejillones Mejillones 2 4 5 9 10 11 11 12 24 13 52 13 15 23 51 2

Company requirements for unannounced drug testing were that it should be carried out every 12 months but records showed the 8-1-61 interval between the last two drug tests was 26 months, carried out on 31 March 2009 and 18 January 2007 There was a slight leak on the chemical safety equipment breathing 8-2-5 apparatus shown by a drop of more than 10 atmospheres in one minute on the gauge The fuel tank gauge in the rescue boat was broken and the fuel 10-1-9 tank was only approximately half full There was no evidence that the Company provided energy 11-1-41 conservation training to all crew Helicopter Guidelines and Mooring equipment guidelines were old editions. MARPOL Annex VI not on board During previous Operator period charts were corrected using red ink Portable VHF radios with batteries expired. SARTS with batteries expired. Port side windlass with minor oil leak.

2009 2009 2009 2009 2009 2009 2009 2009

Nomenclator was 2008 edition 2 purifier fuel pumps with minot leaks Gyro repeater light was burnt Hull with extensive marine growth, especially starboard side. Vessel at anchor at Mejillones for near 3 months The Chief officer worked periods in excess of 36 hours on 4 occasions in March and April with less than 4 hours rest The Chief officer worked periods in excess of 36 hours on 4 occasions in March and April without less than 4 hours rest Way point numbers were not entered on all chart way points One of the voyage charts was no WGS84 compliant No mention of shift values was mentioned in the passage plan The Chief mate was designated as the Safety officer, he could not produce any objective evidence of formal training in the role At the time of inspection of the Ship Shore Safety check list (1500hrs) it was noted that the check list required 2 hourly checks and had not been completed since 0800hrs. Multiple tanks entry was being carried out on one form with no indication that gas test or the entry check list had been completed for each tank entered. There were no records of regular testing of the portable gas testing equipment The Flash back arrestor at the Acetylene bottle station appeared to be frozen and there was a substantial amount of corrosion on the pipe fitting. The securing catches on life jacket and immersion suit storage box at on the aft upper poop deck were broken. The offshore common manifold and its various connections had many bolts missing 50% of the bolts on the ballast tank inspection covers were missing The Cargo record book did not show a loading of Bio Diesel which took place between the 16th and the 18th April 2009 The No2 starboard fixed tank gauge was not working at the time of inspection. Two of the three hermetic UTI portable tank gauges were also not in a working condition. As 6.22 At the time of inspection many blank flangs and and pipe connections on the offshore manifold had 50% of bolts missing The position indicator for the 60% render point on the mooring winch breaks had not been set and there was no indication as to the brake setting The operators had a policy of operating the engine room in manned condition at all times. Requirements for class maintenance of the UMS notation were being maintained 6-1-7 The vessel was Classed for Unattended Machinery Space Operations, but was being operated manned at sea Following outstanding recommendation was overdue: Verification loading computer software against to approved revised load test cases further to increase of deadweight according to Addendum-1 to loading and stability information booklet. Docu No: P0386-DOC100-001 PEV-1. Due date : 04/18/2009

2009 2009 2009 2009

MAY MAY MAY MAY MAY

CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON

Rotterdam Rotterdam Rotterdam Rotterdam Rotterdam

3 3 4 4 5

2 3 20 24 1

2009

2009

MAY

CHEVRON

Rotterdam

5

7

2009

MAY MAY MAY MAY MAY MAY MAY MAY

CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON CHEVRON

Rotterdam Rotterdam Rotterdam Rotterdam Rotterdam Rotterdam Rotterdam Rotterdam

5 5 5 5 6 6 8 8

24 33 41 54 22 31 5 51

2009

2009

2009 2009 2009 2009

2009

2009

MAY

CHEVRON

Rotterdam

8

73

2009

MAY

CHEVRON

Rotterdam

9

5

2009

MAY

CHEVRON

Rotterdam

11

3

2009 MAY

CDI

RANA

Taicang

1-5-12 2009 MAY CDI RANA Taicang

1-2-6 2009 MAY CDI RANA Taicang

3-1-50 2009 MAY CDI RANA Taicang 5-4-3 2009 MAY 2009 MAY 2009 MAY CDI CDI CDI RANA RANA RANA Taicang Taicang Taicang 7-1-22 8-1-32 6-3-1 2009 MAY CDI RANA Taicang 6-1-23 2009 MAY CDI RANA Taicang

The vessel's flag in the Ship particulars and on the approval stamp in the P&A manual was stated as "PHILIPINES", instead of "SINGAPORE" the present flag. The vessel did not have the Annual Summary of Notices to Mariners (2009) and the Weekly Notice Nos. 50 and 51 of 2008 were observed missing form CHARTCO. The publications on board (ALRS volumes, List of Lights, Sailing Directions etc) were not corrected for the missing notices. Tank cleaning hoses There was no record of continuity check of portable Tank cleaning hoses. No procedures were available for control of Small Craft Alongside. Span gas was not available on board for the calibration of personal multigas detectors. A repair with doubler plate was observed on main sea water pump discharge side elbow. A spare elbow had been received on board. The bunkering checklist did not include provision for checking H2S and Benzene content of the bunkering fuel as required by ISGOTT.

2009 MAY 2009 June 2009 June 2009 June 2009 June 2009 June

CDI PETRONAS PETRONAS PETRONAS PETRONAS PETRONAS

RANA

Taicang NINGBO NINGBO NINGBO NINGBO NINGBO1 2 3

As per the entries in the Oil Record Book Part-II, Anexe-1 cargo slops after decanting were transferred to 25 X 200 Ltrs drums on 11-1-17 deck on 11 April 2009 and were finally landed ashore on 27 April 2009The Emergency generator reserve fuel oil tank required marking for the 18 hours working level was not established Safety breathing apparatus set located at the midship manifold area are not fully charged at only 70 bars when inspected All the forward hydraulic mooring winches marking clamps fot the rendering are not clearly marked While the cargo hose connection, observed 2 crew members was not wearing a proper face shield with goggles. Vsl are discharing Acetic Acid Observed cargo sample are kept inside the safety locker. (Methand) Voyage Chart T&P corrections of the following: 1) BA1592- notice 1556/07 was not removed/deleted 2)BA1759-notice 2275/08, 4740/06 was not corrected 3)BA1126- notice 4531/07was not corrected GMDSS Log was not signed and inspected by the master daily as required by the log book 3rd officer was not familiar of how to use and calibrate the portable HC gas meter The enclosed spare permitfor pumpman, issued from 8th Apr to 4th May 2009n where checks of hydrocarbon was not checked and written as NA. It was also observed on many occasions the permit to the cargo tank entry was not checked the HC content and wirtten as NA Only 1 toxic gas detector was available onboard Chief officer does not have and attend the in-house safety officer cause as he is the designated safety officer on board Vsl carries the 3X chemical suits with integral boots but the attached glaves was observed missing for all 3 suits when inspected The observed pilot ladder side ropes were not constructed to the requirements of IMO Res A667 (16) 2.2.1, which required that the side ropes be continuous with no join below the top step. The observed pilot ladders had side ropes which were joined below the bottom step There was no fixed fire extinguishing system within the sample lockers Bunker samples were being stored within the lockers There was no oil mist detector in the area of the aggregate pumps which were situated within the main machinery compartment There was one condition of class requiring that the boiler automatic

4 5

2009 June 2009 June 2009 June

PETRONAS PETRONAS PETRONAS

NINGBO NINGBO NINGBO

6 7 8

2009 June 2009 June 2009 June 2009 June

PETRONAS PETRONAS PETRONAS PETRONAS

NINGBO NINGBO NINGBO NINGBO

9 10 11

12

2009 JUNE 2009 JUNE 2009 JUNE

BP BP BP

Vancouver Vancouver Vancouver

5 8 11

76 37 25

2009 June 2009 June

SHELL SHELL

TEXAS TEXAS

2 4

15 9

2009 June 2009 June2009 June

SHELL SHELLBP

TEXAS TEXASMejillones 4

5 516

47 55

controls be brought into working order by 10 August 2009 It was noted that the master had not written night orders each night when the vessel was at sea or anchored The ships staff had observed cracks in the hull of the port lifeboat in way of the forward lifting hook after the last drill. A technician boarded the vessel during the inspection but was unable to complete repairs due to limited access One of the immersion suits for the port lifeboat was condemned during the last inspection and had not been replaced Guide to Port Entry was outdated

ER workshop: no means for dividing the hot work & injector test 2009 2009 2009 2009 2009 2009 2009 June June June June June June June BP BP BP BP BP BP BP Mejillones Mejillones Mejillones Mejillones Mejillones Mejillones Mejillones 5 8 8 8 11 11 11 37 8 33 40 1 43 30 stand areas, also no sign to avoid these two tasks simultaneously. There were no records of calculations other than the arrival condition. Both tankcleaning heaters were not blanked Emergency Framo Pump last tested March'09, reportedly due to poor hose condition, already requisitioned (Feb'09), not yet on board No re-checks foreseen in Company Bunkering Checklists No quick closing valve fitted, reportedly requisitioned Forecastle fan shaft cover does not protect over coupling area. Lathe trip does not disconnect the lathe, only stops it while pressed Chief enginner had an experience in chemical tankers from 7 June 2008 to 15 Dec 2008 on previous ship and from 7 March 2009 on this ship, less than 12 months. Chief mate, C/E and first engineer were not holding flag state certificate of "doc to serve as an officer at management level on Singapore tankers while master had certificate 4321 (T) 2007 on BA chart 898 for this harbour chart and 4531 (P) 2007 on BA chart 1126 for approaching chart for next port were not plotted A doubler, size 10mm X10mm, was found on a pipeline- close to flange of main engine cooling pump Magnetic compass heading was not clearly visible from the steering stand of the wheel house No emergency light was not marked in the foam room No proper ballast sampling device was available from No. 1 to 3 double bottom ballast tank centre No.6 port cargo tank vacuum valve was supplying air even in- 60 mm H2o of the tank pressure in spite of the valve was designed to open at- 350mm H2O Some insulation of main deck fresh water line were damaged and partially exposed to air

2009

June BP Ulsan 3 4 BP Ulsan Ulsan Ulsan Ulsan Ulsan 11 4 5 6 8 BP Ulsan Ulsan 8 90 39 26 61 31 56 10 14

2009 2009 2009 2009 2009 2009 2009

June June

BP

June BP June BP June BP June June BP

Rectificatio Closed-out n