MB3G2 Vertical Round Accent LED LIGHT ENGINE 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning LED mounted to die-cast / extruded aluminum heat sink 50,000 hours average rated life at 70% output OPTICS 17° Spot, 30° Narrow Flood, and 55° Wide Flood ELECTRICAL SYSTEM 120V-277V 50/60Hz input Class 2 power supply Over voltage, over current and short circuit protection: Auto recovery This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty. DIMMING Must specify -DIM for Phase Dimming Forward / Reverse phase dimming Phase dimming in 120V only Dimmable 100 - 10% TRACK COMPATIBILITY Track luminaire is designed for use with the following track systems: Intense Single Circuit/Single Neutral 120V Intense Two Circuit/Single Neutral 120V (No Dimming) Pro-Series Two Circuit / Two Neutral 120V Pro-Series Two Circuit / Two Neutral 277V (No Dimming) J-Type & L-Type Adapter are for Single / Two Circuit ACCESSORIES Luminaire will accommodate (2) Filter Media, an accessory holder is required. LISTING/WARRANTY ETL Listed to US and Canadian standards for dry locations 5-Year Intense LED Limited Warranty ENERGY STAR ® Qualified 2 2 6 3/8” 4 7/8” 8” 7 15/16” 10 1/2” ELECTRICAL DATA LED Light Engine System Wattage * CCT / CRI Delivered Lumens ** L1 L2 L3 24W 34W 45W 3000K / 82 CRI 3000K / 82 CRI 3000K / 82 CRI 2500lm 3200lm 3900lm * System Wattage include driver and LED Module consumption ** Delivered lumen output will vary depending on CCT, CRI and optic Horizontal Adjustability: 358° Vertical Adjustability: 258° Notes: 1. Consult factory for lead times 2. Dimming available in 120V only Luminaire Part Number (Example: MB3G2L430W-24) Luminaire Wattage CCT / CRI Driver Finish Beam Spread Adapter MB3G2 L1 L2 L3 (24 Watts) (34 Watts) (45 Watts) 27 279 30 309 35 359 1 41 419 1 (2700K / 82 CRI) (2700K / 92 CRI) (3000K / 82 CRI) (3000K / 92 CRI) (3500K / 82 CRI) (3500K / 92 CRI) (4100K / 82 CRI) (4100K / 92 CRI) blank -DIM 2 (Non-Dimming) (Phase Dimming) W B SV (White) (Black) (Silver) -17 -30 -55 (17° Spot) (30° Narrow Flood) (55° Wide Flood) blank -PS -PS-27 2 -J -L (Intense Single / Two Circuit 120V) (Pro-Series 120V) (Pro-Series 277V) (J-Type Single / Two Circuit Adapter 120V) (L-Type Single / Two Circuit Adapter 120V) Accessory Holder LH1 LH1W (Accessory Holder, Black) (Accessory Holder, White) Accessories PFL98-1 PFL98-2 PFL98-3 PFL98-4 PFL98-L (Prismatic Spread Lens) (Linear Spread Lens) (Sand Blasted Lens) (Soft Focus Lens) (Black Louver) JOB NAME CATALOG NUMBER NOTES TYPE MB-TRACK LIGHTING L/M-0514:19 P-1 INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321. © 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Vertical Round Accent - Intense Lighting · MB3G2 Vertical Round Accent LED LIGHT ENGINE 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning LED mounted to die-cast

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • MB3G2Vertical Round Accent

    LED LIGHT ENGINE ■ 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning

    ■ LED mounted to die-cast / extruded aluminum heat sink ■ 50,000 hours average rated life at 70% output

    OPTICS17° Spot, 30° Narrow Flood, and 55° Wide Flood

    ELECTRICAL SYSTEM ■ 120V-277V 50/60Hz input ■ Class 2 power supply ■ Over voltage, over current and short circuit protection: Auto recovery

    ■ This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty.

    DIMMINGMust specify -DIM for Phase Dimming

    ■ Forward / Reverse phase dimming ■ Phase dimming in 120V only ■ Dimmable 100 - 10%

    TRACK COMPATIBILITYTrack luminaire is designed for use with the following track systems:

    ■ Intense Single Circuit/Single Neutral 120V ■ Intense Two Circuit/Single Neutral 120V (No Dimming) ■ Pro-Series Two Circuit / Two Neutral 120V ■ Pro-Series Two Circuit / Two Neutral 277V (No Dimming) ■ J-Type & L-Type Adapter are for Single / Two Circuit

    ACCESSORIESLuminaire will accommodate (2) Filter Media, an accessory holder is required.

    LISTING/WARRANTY ■ ETL Listed to US and Canadian standards for dry locations ■ 5-Year Intense LED Limited Warranty ■ ENERGY STAR® Qualified 2

    2

    6 3/8” 4 7/8”

    8”

    7 15/16” 10 1/2”

    ELECTRICAL DATA

    LED Light Engine System Wattage * CCT / CRI Delivered Lumens **

    L1L2L3

    24W34W45W

    3000K / 82 CRI3000K / 82 CRI3000K / 82 CRI

    2500lm3200lm3900lm

    * System Wattage include driver and LED Module consumption** Delivered lumen output will vary depending on CCT, CRI and optic

    Horizontal Adjustability: 358°Vertical Adjustability: 258°

    Notes: 1. Consult factory for lead times2. Dimming available in 120V only

    Luminaire Part Number (Example: MB3G2L430W-24)

    Luminaire Wattage CCT / CRI Driver Finish Beam Spread Adapter

    MB3G2 L1L2L3

    (24 Watts)(34 Watts)(45 Watts)

    2727930309353591

    414191

    (2700K / 82 CRI)(2700K / 92 CRI)(3000K / 82 CRI)(3000K / 92 CRI)(3500K / 82 CRI)(3500K / 92 CRI)(4100K / 82 CRI)(4100K / 92 CRI)

    blank-DIM2

    (Non-Dimming)(Phase Dimming)

    WBSV

    (White)(Black)(Silver)

    -17-30-55

    (17° Spot)(30° Narrow Flood)(55° Wide Flood)

    blank-PS-PS-272

    -J-L

    (Intense Single / Two Circuit 120V)(Pro-Series 120V)(Pro-Series 277V)(J-Type Single / Two Circuit Adapter 120V)(L-Type Single / Two Circuit Adapter 120V)

    Accessory Holder

    LH1LH1W

    (Accessory Holder, Black)(Accessory Holder, White)

    Accessories

    PFL98-1PFL98-2PFL98-3PFL98-4PFL98-L

    (Prismatic Spread Lens)(Linear Spread Lens)(Sand Blasted Lens)(Soft Focus Lens)(Black Louver)

    JOB NAME

    CATALOG NUMBER

    NOTES TYPE

    MB-TRACK LIGHTING L/M-0514:19 P-1

    INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

  • MB3G2L130Report #: L111402101 (-17) L101408201 (-30) L101408202 (-55)

    0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL 60° VERTICAL

    D FC W L D C FC W L D C FC W L D C FC W L

    MB3G2L130-173000K

    17° Spot

    5.0’7.5’10’

    12.5’

    46620711774.6

    1.452.172.9

    3.62

    1.452.172.9

    3.62

    5.0’7.5’10’

    12.5’

    2.754.255.57

    30613576.548.9

    1.872.813.714.64

    1’ 9”2’ 6”3’ 2”3’ 9”

    3’4’5’6’

    4.56

    7.59

    18910667.947.1

    1.592.112.323.17

    3.034.044.386.08

    3’4’5’6’

    1.752.252.753.25

    831477306212

    0.981.311.631.94

    1.151.491.872.24

    MB3G2L130-303000K

    30° Narrow Flood

    5.0’7.5’10’

    12.5’

    27612268.944.1

    2.714.065.426.77

    2.714.065.426.77

    5.0’7.5’10’

    12.5’

    2.253.254.255.5

    20792.752.233.3

    3.094.596.127.67

    2.724.065.416.77

    3’4’5’6’

    3.755

    6.257.5

    16994.960.742.2

    2.263.023.774.53

    3.334.445.576.68

    3’4’5’6’

    1.251.752.252.5

    576325207144

    1.642.182.733.26

    1.862.473.093.7

    MB3G2L130-553000K

    55° Wide Flood

    5.0’7.5’10’

    12.5’

    10647.226.617

    4.376.558.7410.9

    4.376.558.7410.9

    5.0’7.5’10’

    12.5’

    11.51.752.25

    11952.829.819

    3.745.637.489.21

    4.747.139.4911.9

    3’4’5’6’

    2.53.25

    44.75

    15587.756.139

    3.134.125.186.22

    2.122.813.524.21

    3’4’5’6’

    0.50.75

    11.25

    32518611982.5

    2.843.764.725.69

    2.322.963.674.4

    APPLICATION DATA:

    W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

    W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

    Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

    WL

    FC

    DL

    W

    CD

    60°

    L

    W

    D

    C

    30°

    FC

    D

    LC W

    30°

    1612

    2419

    3225 10° 20°

    Watts: 22.5Lumens: 2413 LPW: 107 CCT: 3000K

    Intensity

    Degree Candela

    0°5°15°25°35°45°

    26562706320022442775

    50°

    40°

    30°

    55° Wide Flood (55)

    80680°

    70°

    60°

    Intensity

    Degree Candela

    0°5°15°25°35°45°

    689069233556129329067

    1738

    3476

    5218

    6951 10°

    80°

    70°

    60°

    50°

    40°

    30°20°

    30° Narrow Flood (30)

    Watts: 24.25Lumens: 2512 LPW: 104 CCT: 3000K

    Intensity

    Degree Candela

    0°5°15°25°35°45°

    116528852229688722069

    2913

    5826

    8739

    11652 10°

    80°

    70°

    60°

    50°

    40°

    30°20°

    17° Spot (17)

    Watts: 26.5Lumens: 2046 LPW: 77 CCT: 3000K

    JOB NAME

    CATALOG NUMBER

    NOTES TYPE

    MB-TRACK LIGHTING L/M-0514:19 P-2

    INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

  • MB3G2L230Report #: L111402101 (-17) L101408201 (-30) L101408202 (-55)

    0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL 60° VERTICAL

    D FC W L D C FC W L D C FC W L D C FC W L

    MB3G2L230-173000K

    17° Spot

    5.0’7.5’10’

    12.5’

    57325514391.7

    1.452.172.9

    3.62

    1.452.172.9

    3.62

    5.0’7.5’10’

    12.5’

    2.754.255.57

    37616694

    60.1

    1.872.813.714.64

    1.632.443.234.05

    3’4’5’6’

    4.56

    7.59

    23213083.457.9

    1.582.122.643.17

    3.034.055.066.08

    3’4’5’6’

    1.752.252.753.25

    1021587376260

    0.981.311.631.95

    1.151.491.872.24

    MB3G2L230-303000K

    30° Narrow Flood

    5.0’7.5’10’

    12.5’

    29513173.947.3

    2.714.065.426.77

    2.714.065.426.77

    5.0’7.5’10’

    12.5’

    2.253.254.255.5

    22299.456

    35.7

    3.094.66.117.68

    2.724.065.416.77

    3’4’5’6’

    3.755

    6.257.5

    18110265.145.2

    2.263.013.774.52

    3.344.445.566.68

    3’4’5’6’

    1.251.752.252.5

    618349222154

    1.642.172.723.27

    1.852.473.093.71

    MB3G2L230-553000K

    55° Wide Flood

    5.0’7.5’10’

    12.5’

    14263.235.522.7

    5.287.9310.613.2

    5.287.9310.613.2

    5.0’7.5’10’

    12.5’

    11.51.752.25

    16071.140.125.7

    3.745.677.469.31

    4.727.089.4511.8

    3’4’5’6’

    2.53.25

    44.75

    20711774.651.9

    3.094.15.186.2

    2.132.833.554.24

    3’4’5’6’

    0.50.75

    11.25

    432247158110

    2.853.774.725.68

    2.353.023.714.41

    APPLICATION DATA:

    W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

    W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

    Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

    WL

    FC

    DL

    W

    CD

    60°

    L

    W

    D

    C

    30°

    FC

    D

    LC W

    30°

    2168

    3252

    4336 10° 20°

    Watts: 32.1Lumens: 3227 LPW: 101 CCT: 3000K

    Intensity

    Degree Candela

    0°5°15°25°35°45°

    35523599424929833836

    50°

    40°

    30°

    55° Wide Flood (55)

    108480°

    70°

    60°

    Intensity

    Degree Candela

    0°5°15°25°35°45°

    738874233813138631172

    1863

    3727

    5590

    7454 10°

    80°

    70°

    60°

    50°

    40°

    30°20°

    30° Narrow Flood (30)

    Watts: 34.25Lumens: 2694 LPW: 79 CCT: 3000K

    Intensity

    Degree Candela

    0°5°15°25°35°45°

    14325108812822109127082

    3581

    7162

    10743

    14324 10°

    80°

    70°

    60°

    50°

    40°

    30°20°

    17° Spot (17)

    Watts: 34Lumens: 2515 LPW: 74 CCT: 3000K

    JOB NAME

    CATALOG NUMBER

    NOTES TYPE

    MB-TRACK LIGHTING L/M-0514:19 P-3

    INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

  • MB3G2L330Report #: L111402101 (-17) L101408201 (-30) L101408202 (-55)

    0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL 60° VERTICAL

    D FC W L D C FC W L D C FC W L D C FC W L

    MB3G2L330-173000K

    17° Spot

    5.0’7.5’10’

    12.5’

    676301169108

    1.52.172.9

    3.62

    1.52.172.9

    3.62

    5.0’7.5’10’

    12.5’

    2.754.255.57

    44419711171

    1.872.793.724.64

    1.632.433.234.05

    3’4’5’6’

    4.56

    7.59

    27415498.568.4

    1.592.122.643.16

    3.034.045.066.07

    3’4’5’6’

    1.752.252.753.25

    1206693444307

    0.981.311.631.95

    1.151.491.872.24

    MB3G2L330-303000K

    30° Narrow Flood

    5.0’7.5’10’

    12.5’

    42418810667.8

    2.583.865.146.42

    2.583.865.146.42

    5.0’7.5’10’

    12.5’

    2.253.254.255.5

    31914380.451.2

    3.094.596.117.67

    2.724.055.416.77

    3’4’5’6’

    3.755

    6.257.5

    26014693.564.9

    2.263.013.774.52

    3.334.445.566.68

    3’4’5’6’

    1.251.752.252.5

    886501319222

    1.642.172.723.26

    1.862.473.093.69

    MB3G2L330-553000K

    55° Wide Flood

    5.0’7.5’10’

    12.5’

    16271.840.425.9

    5.277.9110.513.2

    5.277.9110.513.2

    5.0’7.5’10’

    12.5’

    11.51.752.25

    18280.945.729.2

    3.755.637.479.36

    4.737.129.4511.8

    3’4’5’6’

    2.53.25

    45

    23313183.958.4

    3.184.235.346.37

    2.12.813.514.19

    3’4’5’6’

    0.750.75

    11.25

    498281180126

    2.843.794.755.7

    2.243

    3.684.37

    APPLICATION DATA:

    W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

    W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

    Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

    WL

    FC

    DL

    W

    CD

    60°

    L

    W

    D

    C

    30°

    FC

    D

    LC W

    30°

    2433

    3724

    4966 10° 20°

    Watts: 39.4Lumens: 3690 LPW: 94 CCT: 3000K

    Intensity

    Degree Candela

    0°5°15°25°35°45°

    4039.184217.34932.613143.31299.950

    50°

    40°

    30°

    55° Wide Flood (55)

    124180°

    70°

    60°

    Intensity

    Degree Candela

    0°5°15°25°35°45°

    106001065054701989447104

    2674

    5347

    8021

    10694 10°

    80°

    70°

    60°

    50°

    40°

    30°20°

    30° Narrow Flood (30)

    Watts: 40.25Lumens: 3864 LPW: 96 CCT: 3000K

    Intensity

    Degree Candela

    0°5°15°25°35°45°

    169121284733321288319101

    4228

    8456

    12684

    16912 10°

    80°

    70°

    60°

    50°

    40°

    30°20°

    17° Spot (17)

    Watts: 45Lumens: 2969 LPW: 67 CCT: 3000K

    JOB NAME

    CATALOG NUMBER

    NOTES TYPE

    MB-TRACK LIGHTING L/M-0514:19 P-4

    INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

    A1: OffA2: OffA3: OffA4: OffA5: OffA6: OffB1: OffCheck Box 8: OffCheck Box 7: OffCheck Box 6: OffCheck Box 5: OffCheck Box 9: OffText Field 5: Page 1: Page 2: Page 3: Page 4:

    Text Field 6: Page 1: Page 2: Page 3: Page 4:

    Text Field 7: Page 1: Page 2: Page 3: Page 4:

    Text Field 8: Page 1: Page 2: Page 3: Page 4: