12
VERTICAL BLINDS AND CONSERVATORY AWNINGS safe timeless beautiful Tensioned vertical cassette blind with tracfix system – particularly stable in windy conditions – without cover gap – optionally with fly screen www.markilux.com markilux markilux 660 rated to wind resistance class 3 according to EN 13561 corresponding to Beaufort force 6. Above and beyond the European standard, the wind stability can be guaranteed to Beaufort force 8

VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

V E R T I C A L B LI N D S A N D CO N S E R VAT O RY A W N I N G S s af e • t im e le s s • b ea u t i f u l

Tensioned vertical cassette blind with tracfix system – particularly stable in windy conditions – without cover gap – optionally with fly screen

www.markilux.com markilux

markilux 660

rated to wind resistance class 3

according to EN 13561 corresponding

to Beaufort force 6.

Above and beyond the European

standard, the wind stability can be

guaranteed to Beaufort force 8

Page 2: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

markilux 660 tracfix V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S

100 | Special features w w w . m a r k i l u x . c o m

Design Features

vertical blind with closed tensioning system; ideal protection from the sun, wind and inquisitive glances

attractive, completely closed appearance with no annoying gap between the blind cover and guide tracks

compact, square and discreet, the cassette profile made of extruded aluminium is only 110 mm high and 95 mm deep

when retracted both the cover and the optional fly screen are protected from the weather by their cassettes, which enclose them completely

the fixing screws are hidden at the front by a second profile that is simply clipped on

no visible cover seam at the bottom profile

Technical Specification

with tracfix system – during extension the blind cover or fly screen is connected laterally to the guide rails

the blind cover is guided along sturdy aluminium guide tracks; the partly elastic interior track ensures optimum cover tension and noise minimisation in windy conditions

fitted with a hard-wired motor as standard

the combination of the closed ten-sioning system and special vario-belts ensure optimum cover tension

fixture of the guide tracks directly to the wall, the window frame or the reveal

when fully extended the tracks do not extend past the front profile

when fitted with a fly screen the frame is closed at the bottom

Optional Accessories

optionally fitted with a fly screen, which can be found in the integrated fabric cassette for the fly screen at the bottom

the tension in the fly screen is provided by an internal spring mechanism

optionally the frame can be closed at the bottom with an additional end profile – in which case the front profile is equipped with a brush seal at the bottom

radio-controlled motor with radio remote control for ease of use

an easily installed, radio control light and wind sensor guarantees comfort and a degree of safety

awning available in non-standard RAL colours

standard version with awning fabric –when fully open the guide tracks do not extend past the bottom profile

optionally with closed frame at the bottom, which simplifies installation in the case of face fixture

optionally with fly screen in a separate cassette which closes off the frame at the bottom

Page 3: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S markilux 660 tracfix

w w w . m a r k i l u x . c o m Special features | 101

15

14

13

12

11

02

01

21

20

19

18

17

16

03

04

05

06

07

08

09

10

side view – cover cassette with guide track

blind extended with frame profile and brush seal to complete the frame (optional)

in cross section – lateral guide track with tracfix system and clip-on front profile hiding the fixture screws

cross section – guide track with tracfix system and internal plastic profile guiding the cover

cross section of the front profile – the bottom cover seam is hidden inside the profile

bottom profile with additional fly screen (optional)

closed appearance thanks to the tracfix system – the tracfix system does away with the annoying gap between the cover and the guide track

blind extended – cassette with fly screen (optional) as bottom profile of the frame

blind with insect screen attached (optional) – locked in place by means of a knurled head screw from inside the house

blind with unconnected fly screen (optional)

Page 4: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

markilux 660 tracfix V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S

102 | Dimensions and configuration options w w w . m a r k i l u x . c o m

dimensions in cm1) smallest possible unit height 65 cm; smallest possible unit height with fly screen 75 cm

Dimensions and configuration options

= hard-wired motor 433 = radio-controlled motor (433 MHz)

= with tracfix

MA = fixture width / order widthMA min. = minimum fixture widthAH = unit height

standard optional

hard-wired motor —

radio-controlled motor (433 MHz) —

io radio-controlled motor —

Operation / Drive unit

= optionally with fly screen =

MA

75 100 125 165 205 245 285 30059—75

76—

100101—

125126—

165166—

205206—

246246—

285286—

300MAmin.

+ 4.8 433

AH

1501)

59 74.5200250300

standard optional

traffic white RAL 9016

metallic aluminium RAL 9006

grey brown, similar to RAL 8019

non-standard powder-coated finish

Frame colours

Colours similar to those in the RAL chart. Colours may differ slightly from those depicted in both hue and finish.

Covers

fabric range no. standard optional

sunsilk snc 324 .. / 328 .. / 369 .. —

sunvas snc 310 .. / 311 .. 313 .. — 315 .. —

sunsilk perla FR 374 .. / 379 .. —transolair 338 .. —vuscreen ALU 317 .. —vuscreen FR 318 .. —sunvas perla 370 .. —

3) with bottom profile to complete the frame4) with fly screen

2) standard version

width drophousing tolerances + 5 / − 10

blind cover width = width − 32 2)4)

blind cover length = unit height− 50 2)

− 75 3)

− 138 4)

Dimensions and tolerances

dimensions in mm

Page 5: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S markilux 660 tracfix

15

14

13

12

11

02

01

21

20

19

18

17

16

03

04

05

06

07

08

09

10

w w w . m a r k i l u x . c o m Miscellaneous / Additional information | 103

standard optional

tracfix —

light and wind sensor —

bottom profile to complete the frame —

fly screen —

MiscellaneousFixture / order width definition: The order width is the blind fixture width i.e. the measurement from fixture point to fixture point. The overall width is larger than the fixture width. The tolerance in the width is +0 mm / −10 mm.

In the case of motor operation the blind will take approx. 15 seconds per metre to extend.

N.B! If the motor is used continuously it will stop automatically after 3 to 4 minutes to prevent overheating.

In the case of a bank of blinds operating simultaneously, the same speed of rotation of the motors cannot be guaran-teed because of the internal tolerances of the motors.

This model is only available as a single unit.

Depending on the size of the blind, deflection may be in evidence in individual profiles and sections of profile which is completely unavoidable. This affects neither the functionality nor the durability of the awning.

Additional information

Page 6: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

markilux 660 tracfix V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S

104 | Fixtures, fittings and accessories w w w . m a r k i l u x . c o m

33

80 246,50 fixture type 10

flat track bracketassembly

height 15 mm

78548.

fixture type 20

track bracketassemblywith adjustable head

height 80 mm

78451.

track bracketassembly with adjustable head

height 100 mm

78538.

track bracketassembly with adjustable head

height 140 mm

78539.

track bracket assemblywith adjustable headsee “Fixture dimensions of track brackets with adjustable head”

height 100—500 mm

78540.

��

��

��fixture type 10

double flat track bracket assembly

2 single units

73101.

85

11040

8,5

fixture type 20double track bracket assemblywith adjustable head2 single units

height 80 mm

73102.

85

11040

8,5

double track bracket assemblywith adjustable head

2 single units

height 100 mm

73103.

85

11040

8,5

double track bracket assemblywith adjustable head

2 single units

height 140 mm

73104.

footprint dimensions of adjustabletrack bracket

decorative cap assemblyfor track bracketto be used with:78081., 78086., 78094., 78247., 78451., 78538., 78543., 78454., 78663.

76603.

decorative cap assemblyfor track bracketto be used with:78082., 78087., 78095., 78105., 78107., 78108., 78251., 78539., 78540., 78545., 78665., 78664.,78685.

76604.

reducing bolt assemblyM 10 → M 6 / SW 13

30 mm length

refer to the section“Technical Information”

753211

Fixtures, fittings and accessoriesmarkilux 660 tracfix

The track fixture brackets for the markilux 660 tracfix are the same as those used for other markilux vertical blinds and awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with other markilux vertical blinds and awnings (without tracfix system), the track is 5 mm further away from the substrate, in this respect please see “Dimension overview markilux 660 tracfix”.

. = insert RAL colour code no.

Page 7: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S markilux 660 tracfix

15

14

13

12

11

02

01

21

20

19

18

17

16

03

04

05

06

07

08

09

10

w w w . m a r k i l u x . c o m Fixture combinations / Fixture types | 105

All brackets incur a surcharge

Face fixture

number of drill holes per guide track2 drill holes up to a unit height of 1200 mm3 drill holes up to a unit height of 2200 mm4 drill holes up to a unit height of 3000 mm

Individual bracket combinations – see “Fixtures, fittings and accessories”.

Lateral fixture in the reveal

number of drill holes per guide track2 drill holes up to a unit height of 1200 mm3 drill holes up to a unit height of 2200 mm4 drill holes up to a unit height of 3000 mm

2 fixture brackets per guide track

2 fixture brackets per guide track

Fixture combinations / Fixture types

Fixture type8

Fixture type9

Fixture type10

Fixture type20

78548.

20

78451.

85

Page 8: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

markilux 660 tracfix V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S

106 | Dimension overviews w w w . m a r k i l u x . c o m

Single unit, 1 motor

2 single units, 2 motors

Dimension overview markilux 660 tracfix

MD 1D 2D 3D 4

EAMMA

BA

AHSF

=====

===

=

==

motordetail of the standard versiondetail of the version with optional bottom frame profiledetail of version with optional fly screendetail of the dimensions at the contact point of 2 single units

single unitoverall blind widthblind fixture width = distance between fixing points when using brackets (fixture combinations 10, 20)distance between fixing points when using brackets (fixture combinations 10, 20)unit height = order heightvisible cover area

110

SF

AH

D1

48

AH

D2

AH

D3

M

SF 48

D1-3

48

70A

H

48

70

25 AH

D1

D2

D3

48

7088

AH

M = EA

24 24MA = BA11

0SF

AH

D1

AH

D3

AH

D2

48 48SF

48 48SF

M = EA M = EA

24 24 24 24MA = BAMA = BA

D1-3

D4

M M

24

24

M M D4

dimensions in mm

dimensions in mm

Page 9: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S markilux 660 tracfix

15

14

13

12

11

02

01

21

20

19

18

17

16

03

04

05

06

07

08

09

10

w w w . m a r k i l u x . c o m Dimension overviews | 107

Dimension overview markilux 660 tracfix

AHMAUINMAXXXFW

=======

unit height = order heightoverall blind widthexteriorinteriorblind fixture width / order widtheven drill hole distributiondistance between fixing points when using fixture type 8 = overall blind width – 40 mm

Standard with completely sealed frame at the bottom (optional)

with fly screen(optional)

Fixture type 8 (face fixture)

76

48

AU AU AUIN IN IN

88

AH

110

95

110

AH

95 95

2511

0

48 48

AH

M2424 MA95

110

AH

210

100

48

48

165

48

XXX

BA = M - 40

dimensions in mm

dimensions in mm

Page 10: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

markilux 660 tracfix V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S

108 | Dimension overviews w w w . m a r k i l u x . c o m

Fixture type 9 (lateral fixture to the window reveal)

Fixture type 10 (2 fixture brackets per guide track)

Dimension overview markilux 660 tracfix

dimensions in mm

dimensions in mm

95

AH

100

210

M

24 24MA

5,5

10,5

NB

110

XXX

31

BA

INAU

31 45

BA

110

max

. 300

min

. 170

max

. 500

min

. 100

AH

115

95

M24 24

MA = BA

48

20

48

SF

163

48

MMAAHBAmin.max.SF

=======

overall blind widthblind fixture width / order widthunit height = order heightwidth between fixture points minimummaximumvisible cover area

Page 11: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S markilux 660 tracfix

15

14

13

12

11

02

01

21

20

19

18

17

16

03

04

05

06

07

08

09

10

M

24 24MA

M

M 24 24MA = BA

48 48

24 24MA = BA

2020

78548.

484848 48

85 85

78451.

M

24 24MA

4848

BA = M - 4020 20

BA

AU

IN

48 31

MMA

BAmin.

max.78548.78451.AU

IN

==

==

=====

overall blind widthblind fixture width = width between fixture points = order widthwidth between fixture points minimum

maximumflat track brackettrack bracket with adjustable head, 80 mmexteriorinterior

dimensions in mm

dimensions in mm

Fixture type 20 (2 fixture brackets per guide track)

Cross section fixture types 8, 9, 10, 20

Fixture type 8

Fixture type 10

Fixture type 9

Fixture type 20

Dimension overview markilux 660 tracfix

w w w . m a r k i l u x . c o m Dimension overviews | 109

95

180

48

M24 MA = BA

48 48

165

24

110

max

. 300

min

. 170

max

. 500

min

. 100

AH

Page 12: VERTICAL BLINDS AND CONSERVATORY AWNINGS safe …...awnings (the one exception being the track bracket for 2 single units). Constraints in the design mean that, in comparison with

markilux 660 tracfix V E R T I C A L B L I N D S A N D C O N S E R V A T O R Y A W N I N G S

110 | Dimension overviews w w w . m a r k i l u x . c o m

Dimensions for reveal fixture of the cassette – bracket fixing dimensions

Cable exit point in the case of motor-driven units

Dimension overview markilux 660 tracfix

TP78548.78451.

====

depth 95 mm: fixture types 8 + 9, depth 115 mm: fixture type 10, depth 180 mm: fixture type 20fixture typeflat track brackettrack bracket with adjustable head, 80 mm

dimensions in mm

dimensions in mm

P 10 + 20

P 8 + 9

10

72

10

23

23

T+20

T

95

110

max

. 300

min

. 170

P 20 P 10

13

15

8 6

13

40 41

15

85110

5080

46