5
VERSYS CONTINUOUS ETG-STG Installation Manual, Page 1 Figure 2 Figure 3 6" OC 6" OC 9/16” SLOT TEE GRID CEILING SYSTEM (STG) 15/16” EXPOSED TEE GRID CEILING SYSTEM (ETG) Figure 1 VERSYS CONTINUOUS - ETG-STG Installation Manual STEP 1 - CEILING PREPARATION REMOVED CEILING TILES CEILING TILES 6" 30", 36", 48" OR 60" RUN LENGTH FIXTURE SLOT/OPENING IN GRID CEILING SYSTEM A) GRID CENTERS TO BE 6" (AS SHOWN IN FIGURE 2 AND FIGURE 3). LENGTH OF GRID OPENING HAS TO BE ACCORDING TO THE ORDERED FIXTURE OR FIXTURES RUNS. B) BEFORE INSTALLING FIXTURES IN GRID CEILING PLEASE REMOVE CEILING TILES NEXT TO FIXTURE SLOT AS SHOWN IN FIGURE 1

VERSYS CONTINUOUS - ETG-STG Installation … continuous etg-stg installation manual, page 6 feed whip (by others) access plate feed wires remove access plate, attach feed whip to access

  • Upload
    haque

  • View
    214

  • Download
    1

Embed Size (px)

Citation preview

VERSYS CONTINUOUS ETG-STG Installation Manual, Page 1

Figure 2 Figure 3

6" OC6" OC

9/16” SLOT TEE GRID CEILING SYSTEM (STG) 15/16” EXPOSED TEE GRID CEILING SYSTEM (ETG)

Figure 1

VERSYS CONTINUOUS - ETG-STG Installation Manual

STEP 1 - CEILING PREPARATION

REMOVED CEILING TILES

CEILING TILES

6"

30", 36", 48" OR 60"RUN LENGTH

FIXTURE SLOT/OPENINGIN GRID CEILING SYSTEM

A) GRID CENTERS TO BE 6" (AS SHOWN IN FIGURE 2 AND FIGURE 3). LENGTH OF GRID OPENING HAS TO BE ACCORDING TO THE ORDERED FIXTURE OR FIXTURES RUNS.

B) BEFORE INSTALLING FIXTURES IN GRID CEILING PLEASE REMOVE CEILING TILES NEXT TO FIXTURE SLOT AS SHOWN IN FIGURE 1

VERSYS CONTINUOUS ETG-STG Installation Manual, Page 2

Figure 2 Figure 3

Figure 1

VERSYS CONTINUOUS - ETG-STG Installation Manual

STEP 2 - FIXTURE PREPARATION

1) REMOVE FIXTURE FROM PACKAGING BOX.2) FROM "BOR" AND "INT" MARKED FIXTURES REMOVE WIREWAY SIDE COVERS AND JOINING BOLTS AND NUTS AS SHOWN IN FIGURE 1.

WIREWAYSIDE COVERS

JOINING BOLTS(1/4-20 3/4"LONG)

1/4-20 HEX NUTS

#8-3/8" LONGPAN HEAD SCREW

ALIGNERBRACKET

JOINERBRACKET

THROUGHWIRE

MOUNTINGBRACKET

DETAIL "A"

IF USING "ETG"*

GRID CEILING SYSTEM

THIS TAB IS AS SHOWN

IN FIGURE 2.

IF USING FIXTURE

IN "STG"** GRID

CEILING SYSTEM

THIS TAB MUST BE

FOLDED OUT AS SHOWN

IN FIGURE 3.

* - "ETG" - 15/16" X 1 1/2" HIGH FLAT "T" GRID CEILING.** - "STG" - 9/16" BOLT "T" X 1 11/16" HIGH SCREW SLOT GRID CEILING.

DETAIL "A"

VERSYS CONTINUOUS ETG-STG Installation Manual, Page 3

Figure 2

Figure 4

"BOR" ("INT")FIXTURE

FIXTURE SLOT/OPENING

"EOR" FIXTURE

TIE WIRE(BY OTHERS) TIE WIRE

(BY OTHERS)

"EOR" FIXTURE

"BOR" ("INT")FIXTURE

C) BRING NEXT FIXTURE ("INT" OR "EOR" AS SHOWN IN FIGURE 3; SECURE FIXTURE TO PLENUM AS DESCRIBED IN PARAGRAPH "B” AND SHOWN IN FIGURE 4.

Figure 1

Figure 3

VERSYS CONTINUOUS - ETG-STG Installation Manual

STEP 3 - FIXTURE INSTALLATION

"BOR"FIXTURE

CEILINGTILE

FIXTURE SLOT/OPENINGIN GRID CEILING SYSTEM

TIRE WIRE(BY OTHERS)

FIXTURE SLOT/OPENINGIN GRID CEILING SYSTEM

"BOR"FIXTURE

CEILINGTILE

* - "IND" - INDIVIDUAL FIXTURE; ** - "BOR" - BEGINNING OF RUN FIXTURE; *** - "INT" - INTERMEDIATE IN RUN FIXTURE;

**** - "EOR - END OF RUN FIXTURE.

* - "IND" - INDIVIDUAL FIXTURE; ** - "BOR" - BEGINNING OF RUN FIXTURE; *** - "INT" - INTERMEDIATE IN RUN FIXTURE;

**** - "EOR - END OF RUN FIXTURE.

A) START INSTALLING FIXTURE FROM LEFT TO RIGHT (CLOCKWISE) STARTING WITH "BOR"** MARKED FIXTURE AS SHOWN IN FIGURE 1.B) ONCE FIXTURE IS INSTALLED IN FIXTURE SLOT/OPENING, PLEASE USE TIE WIRE (AS SHOWN IN FIGURE 2) TO SECURE FIXTURE TO PLENUM ACCORDING TO NEC, UL AND CITY CODES.

VERSYS CONTINUOUS ETG-STG Installation Manual, Page 5

ALIGNER BRACKETWITH SET SCREW

JOINER BRACKET

THROUGH WIRES

SLIDE ALIGN BRACKETTO INTERMEDIATE POSITIONAND USING SET SCREWSALIGN FIXTURE HOUSINGS

JOIN FIXTURESBY 1/4-20 BOLTSAND NUTS

WIRE NUTS

A) FIXTURES INSTALLED IN A SLOT/OPENING WILL LOOK AS SHOWNIN FIGURE 1;B) USE JOINING BOLTS AND HEX NUTS (FROM STEP 2) TO JOIN AND ALIGN FIXTURES AS SHOWN ON FIGURE 2;C) USING PROVIDED (BY NEO-RAY) QUICK CONNECTOR OR WIRE NUTS THROUGH WIRE FIXTURES AS SHOWN IN FIGURE 2.

Figure 2

Figure 1

VERSYS CONTINUOUS - ETG-STG Installation Manual

STEP 4 - CONNECTING THROUGH WIRING AND POWERING INSTALLED FIXTURESWORK FROM BELOW UTILITY COMPARTMENT TO JOIN FIXTURES IN RUN.

BEFORE DOING STEP # 4 AND STEP # 5 WHIP MUST BE WITHOUT POWER!

VERSYS CONTINUOUS ETG-STG Installation Manual, Page 6

FEED WHIP(BY OTHERS)

ACCESSPLATE

FEED WIRES

REMOVE ACCESS PLATE, ATTACH FEED WHIP TO ACCESS PLATE AND CONNECT FIXTURE FEED WIRES TO WHIP.PUT BACK ACCESS PLATE ONTO FIXTURE.

NOTE: FOR DIMMING BALLAST FULL FUNCTIONALITY CUSTOMER HAS TO HAS KEEP LAMPS "ON" MINIMUM 100 HOURS FOR PROPER FULL RANGE DIMMING AND LAMP STABILITY

WIREWAYCOVER.

CEILING TILES

UTILITYCOMPARTMENTCOVER

UTILITYCOMPARTMENT

A) INSTALL WIREWAY COVER IN UTILITY COMPARTMENT AND CLOSE COMPARTMENT BY COVER;B) CLOSE CEILING BY TILES AS SHOWN BELOW.

C) INSTALL LAMPS (NOT BY NEO-RAY).

STEP 6

VERSYS CONTINUOUS - ETG-STG Installation Manual

STEP 5 - POWERING INSTALLED FIXTURES