10
Version 1.02

Version 1 · 10.0.0.201 and on port 1 the value 5559.!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Version 1 · 10.0.0.201 and on port 1 the value 5559.!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

Version 1.02

Page 2: Version 1 · 10.0.0.201 and on port 1 the value 5559.!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

FRONT WIRING DIAGRAM for ProCommander® AX

NETWORK 2

USB for Control and Configuration

NETWORK 1

Page 3: Version 1 · 10.0.0.201 and on port 1 the value 5559.!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

!ssi3# => Sub-Device-ID 3 = A3!sip10.0.0.203# => IP: 10.0.0.203*

FRONT WIRING DIAGRAM for ProCommander® AX & Pro I/OTM network wiring during programming and playback from card

Assign each IP address separately:!spi1=10.0.0.201#!spp1=5559#!spi2=10.0.0.202#!spp2=5559#!spi3=10.0.0.203#!spp3=5559#

Assigns in the lookup table of a ProCommander® for the Sub-Device with ID 1 the IP address 10.0.0.201 and on port 1 the value 5559.

!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*

!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

OR

Commands for IP-address* and port* assignments in ProCommander®:

Assign all IP addresses at once:

!swi10.0.0.201:5559#

Assigns automatically in the lookup table of a ProCommander® for all 32 Sub-Devices the IP addresses, starting with the ID 1 from 10.0.0.201 to ID 32 the IP address 10.0.0.232 and on all ports 1 the value 5559.

Get the internal lookup table of a ProCommander®:!gpa# *example IP address and port

Page 4: Version 1 · 10.0.0.201 and on port 1 the value 5559.!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

!ssi3# => Sub-Device-ID 3 = A3!sip10.0.0.201# => IP: 10.0.0.201*

FRONT WIRING DIAGRAM for ProCommander® AX & Pro I/OTM daisy chain connection via switch during programming and playback from card

!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.201# => IP: 10.0.0.201*

!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

Commands for IP-address* and port* assignments in ProCommander:

!sdi10.0.0.201#

Assigns in the lookup table of a ProCommander® for the Sub-Device with ID 1 to ID 32 the IP address 10.0.0.201. On all ports the value 5559 must be assigned.

Get the internal lookup table of a ProCommander®:!gpa# *example IP address and port

Page 5: Version 1 · 10.0.0.201 and on port 1 the value 5559.!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

!ssi3# => Sub-Device-ID 3 = A3!sip10.0.0.201# => IP: 10.0.0.201*

FRONT WIRING DIAGRAM for ProCommander® AX & Pro I/OTM daisy chain connection during programming and playback from card

!sdi10.0.0.201#

Assigns in the lookup table of a ProCommander® for the Sub-Device with ID 1 to ID 32 the IP address 10.0.0.201. On all ports the value 5559 must be assigned.

!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.201# => IP: 10.0.0.201*

!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

Commands for IP-address* and port* assignments in ProCommander:

Get internal lookup table of a ProCommander®:!gpa# *example IP address and port

Page 6: Version 1 · 10.0.0.201 and on port 1 the value 5559.!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

!ssi3# => Sub-Device-ID 3 = A3!sip10.0.0.203# => Ethernet 1 - IP: 10.0.0.203*

!spo1:5559# =>Ethernet 1 - Port 1: 5559*

!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*

!spo1:5559# => Port 1: 5559*

!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => Ethernet 1 - IP: 10.0.0.201*

!spo1:5559# =>Ethernet 1 - Port 1: 5559*

FRONT WIRING DIAGRAM for ProCommander® AX & mixed ProCommander® AX & Pro I/OTM network connection via switch during programming and playback from card

Assign each IP address separately:!spi1=10.0.0.201#!spp1=5559#!spi2=10.0.0.202#!spp2=5559#!spi3=10.0.0.203#!spp3=5559#

Assigns in the lookup table of a ProCommander® for the Sub-Device with ID 1 the IP address 10.0.0.201 and on port 1 the value 5559.

OR

Commands for IP-address* and port* assignments in ProCommander®:

Assign all IP addresses at once:

!swi10.0.0.201:5559#

Assigns automatically in the lookup table of a ProCommander® for all 32 Sub-Devices the IP addresses, starting with the ID 1 from 10.0.0.201 to ID 32 the IP address 10.0.0.232 and on all ports 1 the value 5559.

Get internal lookup table of a ProCommander®:!gpa# *example IP address and port

Page 7: Version 1 · 10.0.0.201 and on port 1 the value 5559.!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

Rel1

1N

4007

D1 1

1

2

2

3

4

RELAY 1

Rel1

1N

4007

D1 1

1

2

2

3

4

RELAY 4

4/8 Ohm

4/8 Ohm

LEFT +-

LEFT --

RIGHT +-

RIGHT --

DIG

ITA

L IN

5

PS

+: 12V

-24V

DIG

ITA

L IN

6

DIG

ITA

L IN

7

DIG

ITA

L IN

8

max

. 500m

A/2

4V

max

. 500m

A/2

4V

ALWAYS MOUNT FLYBACK DIODE IN REVERSE DIRECTION PARALLEL TO EACH INDUCTIVE LOAD!

GND

REAR WIRING DIAGRAM for ProCommander® AX

PS+: 12V-24V/max. 96Watt

PS: GND

EXTERNAL POWER SUPPLY +

EX

TER

NA

L A

UD

IO-A

MPLIF

IER

ALWAYS TAKE CARE OF POWER POLARITY!

RS485/ CAN

ANALOG OUT 1 ANALOG OUT 4max. 10mA

0-10V

ANALOG IN 1(0-10V)

AN

ALO

G IN

1/

DIG

ITA

L IN

1A

NA

LOG

IN

2/

DIG

ITA

L IN

2A

NA

LOG

IN

3/

DIG

ITA

L IN

3A

NA

LOG

IN

4/

DIG

ITA

L IN

4

ANALOG IN 4(0-10V)

max. 24V DC

INPUT CIRCUIT IN1-IN4IN1-IN4

4K

7

R2

10K

R1

D1

ZD

3V

32

1 1

1

2

2

TO_IN1-4

INPUT CIRCUIT IN1-IN4IN1-IN4

4K

7

R2

10K

R1

D1

ZD

3V

32

1 1

1

2

2

TO_IN1-4

The pin assignment of the IX connector can be found on a

separate page in this wiring diagram!

ATTENTION! IX Connector Type A

Page 8: Version 1 · 10.0.0.201 and on port 1 the value 5559.!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

Rel1

1N

4007

D1 1

1

2

2

3

4

RELAY 4

Rel1

1N

4007

D1 1

1

2

2

3

4

RELAY 1

IN1-IN4

100N

F/5

0V

C1

10K

R2

10K

R1

D1

ZPD

5V

12

1

11

12

2

2

TO_IN1-4

INPUT CIRCUIT IN1-IN4

4/8 Ohm

4/8 Ohm

LEFT +-

LEFT --

RIGHT +-

RIGHT --

DIG

ITA

L IN

1

PS

+: 12V

-24V

DIG

ITA

L IN

2

DIG

ITA

L IN

3

DIG

ITA

L IN

4

max

. 500m

A/2

4V

max

. 500m

A/2

4V

ALWAYS MOUNT FLYBACK DIODE IN REVERSE DIRECTION PARALLEL TO EACH INDUCTIVE LOAD!

GND

REAR WIRING DIAGRAM for ProCommander® AX Gecko

PS+: 12V-24V/max. 96Watt

PS: GND

EXTERNAL POWER SUPPLY +

max. 24V DC

GND

PS-OUT+: 12V-24V/max. 96 Watt

CAN-LOW

CAN-HIGH

EX

TER

NA

L A

UD

IO-A

MPLIF

IER

ALWAYS TAKE CARE OF POWER POLARITY!

GND

PS-OUT+: 12V-24V/max. 96 Watt

RS485 -

RS485 +

The pin assignment of the IX connector can be found on a separate page in this

wiring diagram!

RS485/ CAN

ATTENTION! IX Connector Type A

Page 9: Version 1 · 10.0.0.201 and on port 1 the value 5559.!ssi2# => Sub-Device-ID 2 = A2!sip10.0.0.202# => IP: 10.0.0.202*!ssi1# => Sub-Device-ID 1 = A1!sip10.0.0.201# => IP: 10.0.0.201*

WIRING DIAGRAM for ProCommander® AXPin assignment IX Connector – RS485/ CAN

GND/ CAN-GND

PS-OUT+: 12V-24V

RS485_2_D - / DMX-IN/DMX-OUT

RS485_2_D +/ DMX-IN/DMX-OUT

RS485_1_D - / Servo-OUT (Dynamixel, )

CAN-LOW

CAN-HIGH

PS-OUT+: 12V-24V

GND/ CAN-GND

RS485_1_D + / Servo-OUT (Dynamixel, )

ATTENTION! IX Connector Type AStandardized cable for IX to RJ45 connector: