14
1 Image. Plan. Guide. Pre-op Pre-op Intra-op VERION™ Image Guided System ©2014 Novartis 6/14 VRN14076SKi DR AAMIR ASRAR MRCOphth, FRCS Fellopwship Corneao Refractive Surgery Fellowship Vitreo Retinal Surgery

Verion Machine

Embed Size (px)

DESCRIPTION

Verion Image Guided System for Pre Phaco Measurement.

Citation preview

Page 1: Verion Machine

1

Image. Plan. Guide.

Pre-op Pre-op Intra-op

VERION™ Image Guided System

©2014 Novartis 6/14 VRN14076SKi

DR AAMIR ASRARMRCOphth, FRCS

Fellopwship Corneao Refractive SurgeryFellowship Vitreo Retinal Surgery

Page 2: Verion Machine

22

Introducing the VERION™ Image Guided System

Designed to help you consistently achieve your cataract refractive target

The VERION™ Image Guided System is designed to add greater accuracy and efficiency

during surgical planning and execution. Consisting of the VERION™ Reference Unit and the

VERION™ Digital Marker, it can help enhance the way you perform cataract surgery.

Image. Plan. Guide.

©2014 Novartis 6/14 VRN14076SKi

Page 3: Verion Machine

33

VERION™ Reference Unit

ImageWith a convenient desktop interface, the VERION™ Reference Unit:

• Measures keratometry, pupillometry and other key pre-op parameters

• Captures a high-resolution, diagnostic reference image of the patient’s eye

• Auto-detects scleral vessels, limbus, pupil and iris features

Image. Plan. Guide.

©2014 Novartis 6/14 VRN14076SKi

Page 4: Verion Machine

44

Image - Precise Reference Image for Registration and Tracking

VERION™ Reference Unit takes a high resolution, digital reference image of the patient’s unique eye, capturing scleral vessels, limbus and iris landmarks. This “fingerprint of the eye” is used to:

• Register and track the eye throughout the procedure

• Provide a visual reference of all incisions, capsulotomy and IOL positioning

Page 5: Verion Machine

55

VERION™ Reference UnitPlanThe VERION™ Reference Unit also enables surgeons to quickly and efficiently determine an optimized surgical plan:

• Multiple advanced formula IOL calculations, including lens and power selection

• Incision and implantation axis planning customized for each patient

Image. Plan. Guide.

©2014 Novartis 6/14 VRN14076SKi

Page 6: Verion Machine

66

Plan

With the VERION™ Reference Unit, surgeons can quickly and confidently determine a surgical plan— on patients with and without astigmatism. Optimal IOL selection and lens power can be calculated using multiple, proven formulas in a simple, drop-down format.

Page 7: Verion Machine

77

Plan - Comprehensive Astigmatism ManagementVERION™ Reference Unit also provides advanced astigmatism management to help minimize residual cylinder. This includes calculating:

• Optimum incision locations, Toric lens power, Corneal relaxing incisions, Surgically induced astigmatism (SIA)

Page 8: Verion Machine

88

GuideTo help optimize incision and IOL alignment, the VERION™ Digital Marker displays patient information and images from the VERION™ Reference Unit:

• Features a tracking overlay that enables surgeons to see all incisions and alignment in real time

• Automatically accounts for cyclorotation • Eliminates the need for manual toric

eye markings • Automatically registers the patient for

accurate centering and alignment of multifocal and toric IOLs

• Allows documentation of data to help optimize procedures over time

Image. Plan. Guide.

©2014 Novartis 6/14 VRN14076SKi

VERION™ Digital Marker

Page 9: Verion Machine

99

VERION™ Digital Marker The VERION™ Digital Marker can be used with the LenSx® Laser as well as most surgical microscopes.

With LenSx® Laser: With OR Microscope:

Image. Plan. Guide.

©2014 Novartis 6/14 VRN14076SKi

Page 10: Verion Machine

1010

VERION™ Digital Marker M Surgical Overlay Options

• Incisions Guidance• A Roadmap for Consistency

and Control

Page 11: Verion Machine

1111

VERION™ Digital Marker M Surgical Overlay Options

• Capsulorhexis guidance

Page 12: Verion Machine

1212

VERION™ Digital Marker M Surgical Overlay Options

• Toric IOL axis alignment, Lens positioning guidance

Page 13: Verion Machine

1313

VERION™ Digital Marker M Surgical Overlay Options

• Centration and Finalization

Page 14: Verion Machine

1414

Synchronized Workflow – with Centurion

• Connects with the CENTURION® Vision System wireless foot pedal

• Allows surgeons to activate and deactivate digital overlays

• Provides the right overlay at exactly the right time