AAuuttooddeesskk RRoobboott SSttrruuccttuurraall AAnnaallyyssiiss
VVEERRIIFFIICCAATTIIOONNMMAANNUUAALL
FFOORRSSOOUUTTHHAAFFRRIICCAACCOODDEESS
March 2010
7/29/2019 Verification Manual South Africa Codes
2/28
2010 Autodesk, Inc. All Rights Reserved. Except as otherwise permitted by Autodesk, Inc., thispublication, or parts thereof, may not be reproduced in any form, by any method, for any purpose.Certain materials included in this publication are reprinted with the permission of the copyrightholder.
DisclaimerTHIS PUBLICATION AND THE INFORMATION CONTAINED HEREIN IS MADE AVAILABLEBY AUTODESK, INC. AS IS. AUTODESK, INC. DISCLAIMS ALL WARRANTIES, EITHEREXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIESOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE REGARDING THESEMATERIALS.
TrademarksThe following are registered trademarks of Autodesk, Inc., in the USA and/or other countries:Autodesk Robot Structural Analysis, Autodesk Concrete Building Structures, Spreadsheet Calculator, ATC,
AutoCAD, Autodesk, Autodesk Inventor, Autodesk (logo), Buzzsaw,Design Web Format, DWF, ViewCube, SteeringWheels, and Autodesk Revit.All other brand names, product names or trademarks belong to their respective holders.
Third Party Software Program CreditsACIS Copyright 1989-2001 Spatial Corp. Portions Copyright 2002 Autodesk, Inc.Copyright 1997 Microsoft Corporation. All rights reserved.International CorrectSpell Spelling Correction System 1995 by Lernout & Hauspie SpeechProducts, N.V. All rights reserved.InstallShield 3.0. Copyright 1997 InstallShield Software Corporation. All rights reserved.PANTONE and other Pantone, Inc. trademarks are the property of Pantone, Inc. Pantone, Inc.,2002.Portions Copyright 1991-1996 Arthur D. Applegate. All rights reserved.Portions relating to JPEG Copyright 1991-1998 Thomas G. Lane. All rights reserved. Portions ofthis software are based on the work of the Independent JPEG Group.Portions relating to TIFF Copyright 1997-1998 Sam Leffler. Copyright 1991-1997 SiliconGraphics, Inc. All rights reserved.
Government Use
Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth inFAR 12.212 (Commercial Computer Software-Restricted and DFAR 227.7202 (Rights inRights)Technical Data and Computer Software), as applicable.
7/29/2019 Verification Manual South Africa Codes
3/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
INTRODUCTION ..............................................................................................................................................................................1
STEEL ..............................................................................................................................................................................................2STEEL
1. SABS 0162-1:1993 ......................................................................................................................................................................3
VERIFICATIONEXAMPLE1 -SHEAR RESISTANCE ......................................................................................................................4VERIFICATIONEXAMPLE2 -COMPRESSION AND BIAXIAL BENDING.............................................................................................9VERIFICATIONEXAMPLE3 -BENDING RESISTANCE OF I-SECTIONS ........................................................................................13VERIFICATIONEXAMPLE4 -COLUMN UNDER COMPRESSION AND BENDING..............................................................................19VERIFICATIONEXAMPLE5 -TENSION AND BIAXIAL BENDING....................................................................................................23
March 2010 page i
7/29/2019 Verification Manual South Africa Codes
4/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
INTRODUCTION
This verification manual contains numerical examples for elements of steel structures prepared andoriginally calculated byAutodesk Robot Structural Analysis version 2011. All examples have beentaken from handbooks that include benchmark tests covering fundamental types of behaviourencountered in structural analysis. Benchmark results (signed as Handbook) are recalled, andcompared with results of Autodesk Robot Structural Analysis (signed further as Robot).
Each example contains the following parts:
- title of the problem
- specification of the problem
- Robot solution of the problem
- outputs with calculation results and calculation notes
- comparison between Robot results and exact solution
- conclusions
March 2010 page 1 /25
7/29/2019 Verification Manual South Africa Codes
5/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
SSTTEEEELL
March 2010 page 2 /25
7/29/2019 Verification Manual South Africa Codes
6/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
1. SABS 0162-1:1993
March 2010 page 3 /25
7/29/2019 Verification Manual South Africa Codes
7/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
VERIFICATION EXAMPLE 1- Shear resistance
Example taken from students handbook written by Greg Parrott
(the expert in steel structures designingaccording to SABS 0162-1:1993)
TITLE:Shear resistance.
SPECIFICATION:1180x400(8W 20F) stiffened plate girder simply supported over a span of 12.5 m. All loads given areat the ultimate limit state. Steel 300 W.
SOLUTION:For analysed member pre-defined type of BEAM member may be used. It can be set in Member typecombo-box. Press the Parameters button in DEFINITION-MEMBERS tab, which opens the MEMBERDEFINITION PARAMETERS dialog box.
1. End panelType a new name Beam1 in the Member Type editable field. For defining stiffener spacing, pressMore button. Type 1,00 m in editable field End panel and Interior panel and click OK. Save the newly-
created type of member.
March 2010 page 4 /25
7/29/2019 Verification Manual South Africa Codes
8/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
2. Interior panelType a new name Beam2 in the Member Type editable field. For defining stiffener spacing, pressMore button. Type 3,50 m in editable field End panel and Interior panel and click OK. Save the newly-created type of member.
In the CALCULATIONS dialog box set Member Verification option for member 1 and switch offLimitState Serviceability (only Ultimate Limit State will be analysed). Start the calculations by pressing
Calculations button.
Repeat calculations for member 2, additionally press the Configuration button in CALCULATIONSdialog box. In Configuration dialog box switch on Characteristic points option and press the Optionsbutton. It results in opening the Calculations in Characteristic Points dialog box where switch onCoordinates of additional points option and type 0,0 m in editable field.
March 2010 page 5 /25
7/29/2019 Verification Manual South Africa Codes
9/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
Robot RESULTS:
1. End panelMember Verification dialog box with most significant results data will appear on the screen. Pressing
the line with results for member 1 opens the RESULTS dialog box with detailed results for theanalysed member.
The view of the RESULTS window is presented below. Moreover, the printout note containing thesame results data as in Simplified results tab of the RESULTS window is added.
STEEL DESIGN----------------------------------------------------------------------------------------------------------------------------------------CODE: SABS 0162-1:1993
ANALYSIS TYPE: Member Verification----------------------------------------------------------------------------------------------------------------------------------------
CODE GROUP:MEMBER: 1 POINT: 1 COORDINATE: x = 0.00 L = 0.00 m----------------------------------------------------------------------------------------------------------------------------------------
LOADS:Governing Load Case: 1 TEST----------------------------------------------------------------------------------------------------------------------------------------
March 2010 page 6 /25
7/29/2019 Verification Manual South Africa Codes
10/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
MATERIAL:
STEEL 300W fy = 300.00 MPa----------------------------------------------------------------------------------------------------------------------------------------
SECTION PARAMETERS: IS 1h=122.0 cmb=40.0 cm Ay=160.000 cm2 Az=94.400 cm2 Ax=254.400 cm2tw=0.8 cm Iy=685588.800 cm4 Iz=21338.368 cm4 J=226.663 cm4tf=2.0 cm Zply=12384.800 cm3 Zplz=1618.880 cm3----------------------------------------------------------------------------------------------------------------------------------------
INTERNAL FORCES AND CAPACITIES:Muy = 0.00 kN*m
Mry = 3343.90 kN*mVuz = 718.75 kN
CLASS: = Plastic Vrz = 803.81 kN----------------------------------------------------------------------------------------------------------------------------------------
LATERAL BUCKLING PARAMETERS:----------------------------------------------------------------------------------------------------------------------------------------
BUCKLING PARAMETERS:
About Y axis: About Z axis:----------------------------------------------------------------------------------------------------------------------------------------
VERIFICATION FORMULAS:Muy/Mry = 0.00/3343.90 = 0.00 < 1.00 (13.8.2(a))
Vuz/Vrz = 0.89 < 1.00 (13.4.1) 0.727*Muy/Mry + 0.455*Vuz/Vrz = 0.41 < 1.00 (13.4.1.4)----------------------------------------------------------------------------------------------------------------------------------------
Section OK !!!
2. Interior panel
Member Verification dialog box with most significant results data will appear on the screen. Pressingthe line with results for member 2 opens the RESULTS dialog box with detailed results for theanalysed member.
The view of the RESULTS window is presented below. Moreover, the printout note containing thesame results data as in Simplified results tab of the RESULTS window is added.
March 2010 page 7 /25
7/29/2019 Verification Manual South Africa Codes
11/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
STEEL DESIGN----------------------------------------------------------------------------------------------------------------------------------------
CODE: SABS 0162-1:1993ANALYSIS TYPE: Member Verification----------------------------------------------------------------------------------------------------------------------------------------
CODE GROUP:MEMBER: 2 POINT: COORDINATE: x = 0.00 L = 0.00 m----------------------------------------------------------------------------------------------------------------------------------------
LOADS:Governing Load Case: 1 TEST----------------------------------------------------------------------------------------------------------------------------------------
MATERIAL:
STEEL 300W fy = 300.00 MPa----------------------------------------------------------------------------------------------------------------------------------------
SECTION PARAMETERS: IS 1h=122.0 cm
b=40.0 cm Ay=160.000 cm2 Az=94.400 cm2 Ax=254.400 cm2tw=0.8 cm Iy=685588.800 cm4 Iz=21338.368 cm4 J=226.663 cm4tf=2.0 cm Zey=11239.161 cm3 Zez=1066.918 cm3----------------------------------------------------------------------------------------------------------------------------------------
INTERNAL FORCES AND CAPACITIES:Muy = 701.25 kN*mMry = 3034.57 kN*m
Vuz = 683.75 kN
CLASS: = Slender Vrz = 701.76 kN----------------------------------------------------------------------------------------------------------------------------------------
LATERAL BUCKLING PARAMETERS:----------------------------------------------------------------------------------------------------------------------------------------
BUCKLING PARAMETERS:
About Y axis: About Z axis:----------------------------------------------------------------------------------------------------------------------------------------
VERIFICATION FORMULAS:Muy/Mry = 701.25/3034.57 = 0.23 < 1.00 (13.8.1(a))Vuz/Vrz = 0.97 < 1.00 (13.4.1) 0.727*Muy/Mry + 0.455*Vuz/Vrz = 0.61 < 1.00 (13.4.1.4)
----------------------------------------------------------------------------------------------------------------------------------------
Section OK !!!
COMPARISON:
Shear resistances Robot Handbook
1. Shear resistance Vrz [kN] for end panel 803.8 803.82. Maximum shear on end panel 718.75 718.75
3. Shear resistance Vrz [kN] for internal panel 701.76 701.8
4. Maximum shear on internal panel 683.75 683.750
March 2010 page 8 /25
7/29/2019 Verification Manual South Africa Codes
12/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
VERIFICATION EXAMPLE 2- Compression and biaxial bending
Example taken from students handbook written by Greg Parrott
(the expert in steel structures designingaccording to SABS 0162-1:1993)
TITLE:Steel column of multi-storey steel building. Compression and biaxial bending.
SPECIFICATION:The analysis of a multi-storey building produced the ultimate moments shown below for one of thecolumns between two floors. The ultimate axial load was found to be 2200 kN. Lateral restraint isprovided at both ends of the column. It has been suggested using a 305x305x137 H section. Steel300W.
SOLUTION:Define a new type of member. For analyzed member pre-defined type of member COLUMN may beinitially opened. It can be set in Member type combo-box. Press the Parameters button inDEFINITION-MEMBERS tab, which opens MEMBER DEFINITION PARAMETERS dialog box. Typea new name Column 1 in the Member Type editable field. Double click an Lateral Buckling icon thatopens Lateral Buckling Type dialog box. Select the first icon (Element loaded Symmetrically) and clickOK. Select the icon Lateral Buckling Coefficient Upper Flange that opens Effective Length of Beamsbetween Supports dialog box. Choose third radio-button that set the lateral buckling coefficient to 1.0.Repeat the previous procedure for the lower flange. For defining appropriate load type diagram, pressMore button. Choose the icon for Load type Y and double-click the first icon (Constant or linearly
variable moment) in Load Type dialog box. Repeat the previous procedure for the Load type Z. Savethe newly-created type of the member.
March 2010 page 9 /25
7/29/2019 Verification Manual South Africa Codes
13/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
In the CALCULATIONS dialog box set Member Verification option for member 1 and switch offLimitState Serviceability (only Ultimate Limit state will be analyzed). Now, start the calculations bypressing Calculations button.
Member Verification dialog box with most significant results data will appear on screen. Pressing theline with results for the member 1 opens the RESULTS dialog box with detailed results for theanalyzed member.
The view of the RESULTS window is presented below. Moreover, the printout note containing thesame results data as in Simplified results tab of the RESULTS window is added.
March 2010 page 10 /25
7/29/2019 Verification Manual South Africa Codes
14/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
STEEL DESIGN---------------------------------------------------------------------------------------------------------------------------------------
CODE: SABS 0162-1:1993ANALYSIS TYPE: Member Verification---------------------------------------------------------------------------------------------------------------------------------------
CODE GROUP:MEMBER: 1 POINT: 3 COORDINATE: x = 1.00 L = 3.85 m---------------------------------------------------------------------------------------------------------------------------------------
LOADS:
Governing Load Case: 1 1---------------------------------------------------------------------------------------------------------------------------------------
MATERIAL:
STEEL 300W fy = 300.00 MPa---------------------------------------------------------------------------------------------------------------------------------------
SECTION PARAMETERS: HPF 305x305x137h=32.0 cm
b=30.9 cm Ay=133.976 cm2 Az=44.229 cm2 Ax=174.000 cm2tw=1.4 cm Iy=32800.000 cm4 Iz=10600.000 cm4 J=251.000 cm4tf=2.2 cm Zply=2290.000 cm3 Zplz=1050.000 cm3---------------------------------------------------------------------------------------------------------------------------------------
INTERNAL FORCES AND CAPACITIES:Cu = 2200.00 kN Muy = -220.00 kN*m Muz = 30.00 kN*mCr0 = 4698.00 kN Mry = 618.30 kN*m Mrz = 283.50 kN*m
Vuy = -2.60 kN Vuz = -93.51 kN
CLASS: = Plastic Vry = 2387.45 kN Vrz = 788.16 kN---------------------------------------------------------------------------------------------------------------------------------------
LATERAL BUCKLING PARAMETERS:Le = 3.85 m om2 = 2.500 Mre = 618.30 kN*m
k = -0.636 Mcr = 6695.67 kN*m---------------------------------------------------------------------------------------------------------------------------------------
BUCKLING PARAMETERS:
About Y axis: About Z axis:Ly = 3.85 m Lamy = 0.346 Lz = 3.85 m Lamz = 0.608KyLy = 3.85 m om1y = 0.400 KzLz = 3.85 m om1z = 0.867KyLy/ry = 28.041 U1y = 0.421 KzLz/rz = 49.327 U1z = 1.027---------------------------------------------------------------------------------------------------------------------------------------
VERIFICATION FORMULAS:Cu/Cr0 + 0.85*Muy/Mry + 0.60*Muz/Mrz = 0.834 < 1.000 (13.8.2(a))Cu/Cr1 + 0.85*U1y*Muy/Mry + 0.60*U1z*Muz/Mrz = 0.757 < 1.000 (13.8.2(b))Cu/Crz1 + 0.85*U1y*Muy/Mre + 0.60*U1z*Muz/Mrz = 0.932 < 1.000 (13.8.2(c))
Vuy/Vry = 0.001 < 1.000 (13.4.1) Vuz/Vrz = 0.119 < 1.000 (13.4.1)---------------------------------------------------------------------------------------------------------------------------------------
Section OK !!!
March 2010 page 11 /25
7/29/2019 Verification Manual South Africa Codes
15/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
COMPARISON:
Resistance, interaction expression Robot Handbook
1. Compressive resistance Cr0 [kN] 4698 4698
2. Compressive resistance Cr [kN] 3899.7 3902.1
3. Moment resistance Mry [kNm]
as for laterally supported member
618.3 618.3
4. Moment resistance Mre [kNm]as for laterally unsupported member
18.3 618.3
5. Moment resistance Mrz [kNm] 283.5 283.5
6. Cross-sectional strength check 0.834 0.834
7. Overall member strength check 0.757 0.756
8. Lateral torsional buckling strength check 0.932 0.931
March 2010 page 12 /25
7/29/2019 Verification Manual South Africa Codes
16/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
VERIFICATION EXAMPLE 3- Bending resistance of I-sections
Example taken from students handbook written by Greg Parrott
(the expert in steel structures designingaccording to SABS 0162-1:1993)
TITLE:Bending resistance of I-sections.
SPECIFICATION:The beam (406 x 178 x 67 I section) made of 300W steel has torsional and simple lateral rotationalrestraint at the supports, and the applied point load provides effective lateral restraint at the point ofapplication. The uniformly distributed load will not have a destabilising effect.
SOLUTION:For analysed member pre-defined type of BEAM member may be used. It can be set in Member typecombo-box. Press the Parameters button in DEFINITION-MEMBERS tab, which opens the MEMBERDEFINITION PARAMETERS dialog box. Type a new name Beam1 in the Member Type editablefield. Click an Lateral Buckling icon that opens Lateral Buckling Type dialog box. Select the first icon(Element loaded symmetrically) and click OK. Select the icon Lateral Buckling Coefficient Upperflange that opens Effective Length of Beams between Supports dialog box. Choose third radio-buttonthat set the lateral buckling coefficient to 1.0. Repeat the previous procedure for the lower flange.Save the newly-created type of member.
March 2010 page 13 /25
7/29/2019 Verification Manual South Africa Codes
17/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
For segment 3 type a new name Beam2 in the Member Type editable field. Click an Lateral Bucklingicon that opens Lateral Buckling Type dialog box. Select the second icon (Cantilever) and click OK.Select the icon Lateral Buckling Coefficient Upper flange that opens Effective Length of Beamsbetween Supports dialog box. Choose fifth radio-button that set the lateral buckling coefficient to 1.0.Repeat the previous procedure for the lower flange. Save the newly-created type of member.
In the CALCULATIONS dialog box set Member Verification option for member 1 to 3 and switch offLimit State Serviceability (only Ultimate Limit State will be analysed). Start the calculations bypressing Calculations button.
Member Verification dialog box with most significant results data will appear on the screen. Pressingthe line with results for member 1 opens the RESULTS dialog box with detailed results for theanalysed member.
The view of the RESULTS window is presented below. Moreover, the printout note containing thesame results data as in Simplified results tab of the RESULTS window is added.
March 2010 page 14 /25
7/29/2019 Verification Manual South Africa Codes
18/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
Robot RESULTS:
1. for segment No. 1
STEEL DESIGN----------------------------------------------------------------------------------------------------------------------------------------CODE: SABS 0162-1:1993ANALYSIS TYPE: Member Verification
----------------------------------------------------------------------------------------------------------------------------------------
CODE GROUP:MEMBER: 1 POINT: 3 COORDINATE: x = 1.00 L = 4.00 m----------------------------------------------------------------------------------------------------------------------------------------LOADS: Governing Load Case: 1 Test----------------------------------------------------------------------------------------------------------------------------------------
MATERIAL: STEEL 300W fy = 300.00 MPa----------------------------------------------------------------------------------------------------------------------------------------
SECTION PARAMETERS: IPF 406x178x67h=40.9 cmb=17.9 cm Ay=51.137 cm2 Az=36.027 cm2 Ax=85.500 cm2tw=0.9 cm Iy=24300.000 cm4 Iz=1360.000 cm4 J=46.500 cm4tf=1.4 cm Zply=1350.000 cm3 Zplz=237.000 cm3----------------------------------------------------------------------------------------------------------------------------------------
INTERNAL FORCES AND CAPACITIES:Muy = 318.17 kN*mMry = 364.50 kN*m
Vuz = 26.74 kNCLASS: = Plastic Vrz = 642.00 kN----------------------------------------------------------------------------------------------------------------------------------------
LATERAL BUCKLING PARAMETERS:Le = 4.00 m om2 = 1.750 Mre = 353.27 kN*mk = -0.000 Mcr = 721.28 kN*m
----------------------------------------------------------------------------------------------------------------------------------------BUCKLING PARAMETERS:
About Y axis: About Z axis:----------------------------------------------------------------------------------------------------------------------------------------
VERIFICATION FORMULAS:Muy/Mry = 318.17/364.50 = 0.873 < 1.000 (13.8.2(a))Muy/Mre = 318.17/353.27 = 0.901 < 1.000 (13.8.2(c))Vuz/Vrz = 0.042 < 1.000 (13.4.1)
----------------------------------------------------------------------------------------------------------------------------------------Section OK !!!
March 2010 page 15 /25
7/29/2019 Verification Manual South Africa Codes
19/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
2. for segment No. 2
STEEL DESIGN----------------------------------------------------------------------------------------------------------------------------------------
CODE: SABS 0162-1:1993ANALYSIS TYPE: Member Verification----------------------------------------------------------------------------------------------------------------------------------------
CODE GROUP:MEMBER: 2 POINT: 1 COORDINATE: x = 0.00 L = 0.00 m----------------------------------------------------------------------------------------------------------------------------------------
LOADS:Governing Load Case: 1 Test
----------------------------------------------------------------------------------------------------------------------------------------
MATERIAL:
STEEL 300W fy = 300.00 MPa----------------------------------------------------------------------------------------------------------------------------------------
SECTION PARAMETERS: IPF 406x178x67h=40.9 cmb=17.9 cm Ay=51.137 cm2 Az=36.027 cm2 Ax=85.500 cm2tw=0.9 cm Iy=24300.000 cm4 Iz=1360.000 cm4 J=46.500 cm4
tf=1.4 cm Zply=1350.000 cm3 Zplz=237.000 cm3----------------------------------------------------------------------------------------------------------------------------------------
INTERNAL FORCES AND CAPACITIES:Muy = 318.17 kN*mMry = 364.50 kN*m
Vuz = -77.26 kN
CLASS: = Plastic Vrz = 642.00 kN----------------------------------------------------------------------------------------------------------------------------------------
LATERAL BUCKLING PARAMETERS:Le = 3.00 m om2 = 1.860 Mre = 364.50 kN*mk = -0.102 Mcr = 1253.16 kN*m
----------------------------------------------------------------------------------------------------------------------------------------
BUCKLING PARAMETERS:
About Y axis: About Z axis:----------------------------------------------------------------------------------------------------------------------------------------
VERIFICATION FORMULAS:Muy/Mry = 318.17/364.50 = 0.873 < 1.000 (13.8.2(a))
Muy/Mre = 318.17/364.50 = 0.873 < 1.000 (13.8.2(c))Vuz/Vrz = 0.120 < 1.000 (13.4.1)
----------------------------------------------------------------------------------------------------------------------------------------Section OK !!!
March 2010 page 16 /25
7/29/2019 Verification Manual South Africa Codes
20/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
3. for segment No. 3
STEEL DESIGN----------------------------------------------------------------------------------------------------------------------------------------
CODE: SABS 0162-1:1993ANALYSIS TYPE: Member Verification----------------------------------------------------------------------------------------------------------------------------------------
CODE GROUP:MEMBER: 3 POINT: 1 COORDINATE: x = 0.00 L = 0.00 m----------------------------------------------------------------------------------------------------------------------------------------
LOADS:Governing Load Case: 1 Test
----------------------------------------------------------------------------------------------------------------------------------------
MATERIAL:
STEEL 300W fy = 300.00 MPa----------------------------------------------------------------------------------------------------------------------------------------
SECTION PARAMETERS: IPF 406x178x67h=40.9 cmb=17.9 cm Ay=51.137 cm2 Az=36.027 cm2 Ax=85.500 cm2
tw=0.9 cm Iy=24300.000 cm4 Iz=1360.000 cm4 J=46.500 cm4tf=1.4 cm Zply=1350.000 cm3 Zplz=237.000 cm3
----------------------------------------------------------------------------------------------------------------------------------------
INTERNAL FORCES AND CAPACITIES:Muy = -32.40 kN*mMry = 320.52 kN*m
Vuz = 21.60 kNCLASS: = Plastic Vrz = 642.00 kN
----------------------------------------------------------------------------------------------------------------------------------------
LATERAL BUCKLING PARAMETERS:Le = 3.00 m om2 = 1.750 Mre = 320.52 kN*mk = 0.000 Mcr = 1389.65 kN*m
----------------------------------------------------------------------------------------------------------------------------------------
BUCKLING PARAMETERS:
About Y axis: About Z axis:----------------------------------------------------------------------------------------------------------------------------------------
VERIFICATION FORMULAS:Muy/Mry = 32.40/320.52 = 0.101 < 1.000 (13.8.2(a))Muy/Mre = 32.40/320.52 = 0.101 < 1.000 (13.8.2(c))
Vuz/Vrz = 0.034 < 1.000 (13.4.1)
----------------------------------------------------------------------------------------------------------------------------------------Section OK !!!
March 2010 page 17 /25
7/29/2019 Verification Manual South Africa Codes
21/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
COMPARISON:
Resistance, interaction expression Robot Handbook
SEGMENT 11. Critical moment Mcr [kN]2. Moment resistance Mry [kN]
as for laterally supported member3. Moment resistance Mre [kNm]
as for laterally unsupported member4. Cross-sectional strength check5. Lateral torsional buckling strength check
721.3
364.5
353.30.8730.901
722.2
364.5
353.40.8730.900
SEGMENT 21. Critical moment Mcr [kN]2. Moment resistance Mry [kN]
as for laterally supported member3. Moment resistance Mre [kNm]
as for laterally unsupported member4. Cross-sectional strength check5. Lateral torsional buckling strength check
1253.2
364.5
364.50.8730.873
1255.5
364.5
364.50.8730.873
SEGMENT 3 /cantilever/1. Critical moment Mcr [kN]2. Moment resistance Mry [kN]
as for laterally supported member3. Moment resistance Mre [kNm]
as for laterally unsupported member4. Cross-sectional strength check5. Lateral torsional buckling strength check
1389.7
320.5
320.50.1010.101
1393.8
320.5
320.50.1010.101
CONCLUSION:The differences are caused by different way of rounding-off the cross-sectional properties values
(cross-sectional area, section modulus, moment of inertia).
March 2010 page 18 /25
7/29/2019 Verification Manual South Africa Codes
22/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
VERIFICATION EXAMPLE 4- Column under compression and bending
Examination example for students of Civil Engineering and Surveying Department
at Technikon Natal (South Africa)(written by Greg Parrott, the expert in steel structures designing
according to SABS 0162-1:1993)
TITLE:Column under compression and bending
SPECIFICATION:A first order analysis of the structure produced the bending moments and axial load on the column forthe loads as shown below. Lateral restraint is provideded at both ends of the column. It has beensuggested using a 356 x 171 x 67 I-section. Steel 300W.
SOLUTION:Define a new type of member. For analyzed member pre-defined type of member COLUMN may beinitially opened. It can be set in Member type combo-box. Press the Parameters button inDEFINITION-MEMBERS tab, which opens MEMBER DEFINITION PARAMETERS dialog box. Typea new name Column 1 in the Member Type editable field. Click an Lateral Buckling icon that opensLateral Buckling Type dialog box. Select the first icon (Element loaded Symmetrically) and click OK.Select the icon Lateral Buckling Coefficient Upper Flange that opens Effective Length of Beamsbetween Supports dialog box. Choose third radio-button that set the lateral buckling coefficient to 1.0.Repeat the previous procedure for the lower flange. For defining appropriate load type diagram, pressMore button. Choose the icon for Load type Y and double-click the first icon (Constant or linearly
variable moment) in Load Type dialog box. Repeat the previous procedure for the Load type Z. Savethe newly-created type of the member.
March 2010 page 19 /25
7/29/2019 Verification Manual South Africa Codes
23/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
In the CALCULATIONS dialog box set Member Verification option for member 1 and switch off LimitState Serviceability (only Ultimate Limit state will be analyzed). Now, start the calculations bypressing Calculation button.
Member Verification dialog box with most significant results data will appear on screen. Pressing theline with results for the member 1 opens the RESULTS dialog box with detailed results for theanalyzed member.
The view of the RESULTS window is presented below. Moreover, the printout note containing thesame results data as in Simplified results tab of the RESULTS window is added.
RESULTS:
March 2010 page 20 /25
7/29/2019 Verification Manual South Africa Codes
24/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
STEEL DESIGN---------------------------------------------------------------------------------------------------------------------------------------
CODE: SABS 0162-1:1993ANALYSIS TYPE: Member Verification---------------------------------------------------------------------------------------------------------------------------------------
CODE GROUP:MEMBER: 1 POINT: 3 COORDINATE: x = 1.00 L = 4.00 m---------------------------------------------------------------------------------------------------------------------------------------
LOADS:Governing Load Case: 1 test---------------------------------------------------------------------------------------------------------------------------------------
MATERIAL:
STEEL 300W fy = 300.00 MPa---------------------------------------------------------------------------------------------------------------------------------------
SECTION PARAMETERS: IPF 356x171x67h=36.4 cm
b=17.3 cm Ay=54.385 cm2 Az=33.124 cm2 Ax=85.500 cm2tw=0.9 cm Iy=19500.000 cm4 Iz=1360.000 cm4 J=56.000 cm4tf=1.6 cm Zply=1210.000 cm3 Zplz=243.000 cm3---------------------------------------------------------------------------------------------------------------------------------------
INTERNAL FORCES AND CAPACITIES:Cu = 815.00 kN Muy = 71.90 kN*mCr0 = 2308.50 kN Mry = 326.70 kN*m
Vuz = 32.45 kN
CLASS: = Plastic Vrz = 590.27 kN---------------------------------------------------------------------------------------------------------------------------------------
LATERAL BUCKLING PARAMETERS:Le = 4.00 m om2 = 2.500 Mre = 326.70 kN*m
k = -0.805 Mcr = 992.64 kN*m---------------------------------------------------------------------------------------------------------------------------------------
BUCKLING PARAMETERS:
About Y axis: About Z axis:Ly = 4.00 m Lamy = 0.327 Lz = 4.00 m Lamz = 1.236KyLy = 4.00 m om1y = 0.400 KzLz = 4.00 mKyLy/ry = 26.487 U1y = 0.414 KzLz/rz = 100.294---------------------------------------------------------------------------------------------------------------------------------------
VERIFICATION FORMULAS:Cu/Cr0 + 0.85*Muy/Mry = 0.540 < 1.000 (13.8.2(a))Cu/Cry1 + 0.85*U1y*Muy/Mry = 0.451 < 1.000 (13.8.2(b))Cu/Crz1 + 0.85*U1y*Muy/Mre = 0.954 < 1.000 (13.8.2(c))
Vuz/Vrz = 0.055 < 1.000 (13.4.1)---------------------------------------------------------------------------------------------------------------------------------------
Section OK !!!
March 2010 page 21 /25
7/29/2019 Verification Manual South Africa Codes
25/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
COMPARISON:
Resistance, interaction expression Robot Example
1. Compressive resistance Cr0 [kN] 2308.5 2308.5
2. Compressive resistance Cr [kN] 1062.6 1063.1
3. Moment resistance Mry [kNm]
as for laterally supported member 326.7 326.74. Moment resistance Mre [kNm]
as for laterally unsupported member 326.7 326.7
5. Cross-sectional strength check 0.540 0.540
6. Overall member strength check 0.451 0.451
7. Lateral torsional buckling strength check 0.954 0.954
March 2010 page 22 /25
7/29/2019 Verification Manual South Africa Codes
26/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
VERIFICATION EXAMPLE 5- Tension and biaxial bending
Example taken from students handbook written by Greg Parrott
(the expert in steel structures designingaccording to SABS 0162-1:1993)
TITLE:Tension and biaxial bending.
SPECIFICATION:IPF 356 x 171 x 57 simply supported beam over a span of 8 m. The ultimate axial tensile force wasfound to be 50 kN. Lateral restraint is provided at both ends of the beam. Steel 300W.
SOLUTION:For analysed member pre-defined type of BEAM member may be used. It can be set in Member typecombo-box. Press the Parameters button in DEFINITION-MEMBERS tab, which opens the MEMBERDEFINITION PARAMETERS dialog box. Type a new name Beam1 in the Member Type editablefield. Click an Lateral Buckling icon that opens Lateral Buckling Type dialog box. Select the first icon(Element loaded symmetrically) and click OK. Select the icon Lateral Buckling Coefficient Upperflange that opens Effective Length of Beams between Supports dialog box. Choose third radio-buttonthat set the lateral buckling coefficient to 1.0. Repeat the previous procedure for the lower flange.
Save the newly-created type of member.
March 2010 page 23 /25
7/29/2019 Verification Manual South Africa Codes
27/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
In the CALCULATIONS dialog box set Member Verification option for member 1 and switch offLimitState Serviceability (only Ultimate Limit State will be analysed). Start the calculations by pressingCalculations button.
Member Verification dialog box with most significant results data will appear on the screen. Pressingthe line with results for member 1 opens the RESULTS dialog box with detailed results for theanalysed member.
The view of the RESULTS window is presented below. Moreover, the printout note containing thesame results data as in Simplified results tab of the RESULTS window is added.
Robot RESULTS:
March 2010 page 24 /25
7/29/2019 Verification Manual South Africa Codes
28/28
Autodesk Robot Structural Analysis - Verification Manual South Afric Codes
STEEL DESIGN----------------------------------------------------------------------------------------------------------------------------------------
CODE: SABS 0162-1:1993ANALYSIS TYPE: Member Verification----------------------------------------------------------------------------------------------------------------------------------------
CODE GROUP:MEMBER: 1 POINT: 2 COORDINATE: x = 0.50 L = 4.00 m----------------------------------------------------------------------------------------------------------------------------------------
LOADS: Governing Load Case: 1 ULTIMATE----------------------------------------------------------------------------------------------------------------------------------------
MATERIAL:
STEEL 300W fy = 300.00 MPa----------------------------------------------------------------------------------------------------------------------------------------
SECTION PARAMETERS: IPF 356x171x57h=35.9 cmb=17.2 cm Ay=44.746 cm2 Az=28.688 cm2 Ax=72.200 cm2
tw=0.8 cm Iy=16100.000 cm4 Iz=1110.000 cm4 J=33.400 cm4tf=1.3 cm Zply=1010.000 cm3 Zplz=198.000 cm3----------------------------------------------------------------------------------------------------------------------------------------
INTERNAL FORCES AND CAPACITIES:Tu = -50.00 kN Muy = -80.00 kN*m Muz = 32.00 kN*mTr = 1949.40 kN Mry = 272.70 kN*m Mrz = 53.46 kN*mCLASS: = Plastic
----------------------------------------------------------------------------------------------------------------------------------------
LATERAL BUCKLING PARAMETERS:Le = 8.00 m om2 = 1.00 Mre = 99.80 kN*mk = 0.00 Mcr = 110.89 kN*m
----------------------------------------------------------------------------------------------------------------------------------------
BUCKLING PARAMETERS:
About Y axis: About Z axis:----------------------------------------------------------------------------------------------------------------------------------------
VERIFICATION FORMULAS:Tu/Tr + Muy/Mry + Muz/Mrz =0.92 < 1.00 (13.9(a))Muy/Mre - Tu*Z/(Mre*A) = 0.73 < 1.00 (13.9(b))
Muz/Mrz - Tu*Z/(Mrz*A) = 0.57 < 1.00 (13.9(b))----------------------------------------------------------------------------------------------------------------------------------------
Section OK !!!
COMPARISON:
Resistance, interaction expression Robot Handbook1. Tensile resistance Tr [kN] 1949.4 1949.4
2. Critical moment Mcr [kNm] 110.89 110.86
3. Moment resistance Mry [kNm]as for laterally supported member 272.7 272.7
4. Moment resistance Mre [kNm]as for laterally unsupported member 99.8 99.7
5. Moment resistance Mrz [kNm] 53.46 53.5
6. Cross-sectional strength check 0.92 0.92
7. Lateral torsional buckling strength check 0.73 0.73