VENTILATION. Ventilation Practices. Basic Objectives Ventilation Practices. 8-1.1 Define the principles of ventilation, and identify the advantages and effects of ventilation. 8-1.2 Identify the dangers present, and the precautions to be taken in performing ventilation. - PowerPoint PPT Presentation

Citation preview

Page 1: VENTILATION

1

Page 2: VENTILATION

2

Page 3: VENTILATION

8-1.1 Define the principles of ventilation, and identify the advantages and effects of ventilation.

8-1.2 Identify the dangers present, and the precautions to be taken in performing ventilation.

8-1.3 Demonstrate opening various types of windows from inside and outside, with and without fire department tools.

8-1.4 Demonstrate breaking window or door glass, and removing obstructions.

8-1.5 Using an axe, demonstrate the ventilation of a roof and a floor.

8-1.6 Demonstrate ventilation using a water fog. 8-1.7 Define the theory of a back draft explosion. 8-1.8 Identify the signs of a potential flashover.

3

Page 4: VENTILATION

8-2.1 Demonstrate the use of different types of power saws and jack hammers.

8-2.2 Identify the different types of roofs, demonstrate the techniques used to ventilate each type, and identify the necessary precautions.

8-2.3 Identify the size and location of an opening for ventilation, and the precautions to be taken during ventilation.

8-2.4 Demonstrate the removal of skylights, scuttle covers, and other covers on roof tops.

8-2.5 Demonstrate the types of equipment used for forced mechanical ventilation.

4

Page 5: VENTILATION

8-3.1 Identify and demonstrate natural and mechanical methods for horizontal ventilation of a structure.

8-3.2 Identify and demonstrate natural and mechanical methods for vertical ventilation of a structure.

8-3.3 Identify the location of the opening, the methods to be used, and the precautions to be taken when ventilating a basement.

5

Page 6: VENTILATION

VentilationVentilation is the systematic removal and replacement of heated air, smoke, and gases from a structure, with cooler air

Ventilation facilitates entry by firefighters and improves life safety for rescue and other firefighting operations

Ventilation increases visibility, decreases danger to trapped occupants by channeling away hot, toxic gases, and it reduces the chance of flashover or backdraft

6

Page 7: VENTILATION

Because the increased use of plastics and other synthetics have greatly increased the fuel load in all occupancies, modern technology requires a greater emphasis on ventilation

The products of combustion are becoming more dangerous and are in larger quantities than ever before

Prompt ventilation for the saving of lives, suppression of fire, and reduction of damage is just as important, if not more so, than it ever has been

7

Page 8: VENTILATION

Today’s energy conserving houses create additional ventilation issues

Energy saving glass, steel entry doors, and building vapor barriers make heat retention much greater

This means when there is a fire, the heat is retained better, and flashover can occur faster than in a less insulated structure

8

Page 9: VENTILATION

A roof covering is the exposed part of the roof {the part we see every day} and its purpose is to protect against the weather

It can be wood shingles, composition shingles, composition roofing paper, tile, slate, synthetic membrane, or built up tar and gravel

This is important to us because it may be subjected to sparks or blazing embers from another source

Insulation over the covering retains heat and may reduce fire rating drastically, causing premature roof failure

9

Page 10: VENTILATION

All the preceding mean that the need for ventilation is increased and it must be accomplished much sooner than in the past

We must know how the roofs in our area are constructed

Pre Incident plans need to note roof construction and any areas of a roof over or added insulation

Not any light weight building materials as they can be a serious collapse hazard

10

Page 11: VENTILATION

When the officer decides ventilation is needed, they must consider the precaution necessary to control the fire and assure the safety of teams performing the task

The team must wear full PPE, including SCBA and have a charge hose line available

Before, during , and following the operation it is important to consider the possibility of fire spreading through out a building and the danger of exposure fires

11

Page 12: VENTILATION

All PPE Charged Hose Line Forcible Entry

Tools Chain Saw Rotary Saw Ladders

12

Page 13: VENTILATION

13

Page 14: VENTILATION

Proper Ventilation simplifies and expedites rescue by removing smoke and gases that endanger trapped or unconscious occupants

Replacement of heat, smoke, and gases with cooler, fresh air helps victims breathe better

This will also make condition safer for firefighters and improve visibility so that we may more easily locate the victims

14

Page 15: VENTILATION

15

Page 16: VENTILATION

Vent team and fire attack must coordinate closely

When the hole is cut, a chimney effect is created in the structure

If this hole is cut directly over a fire, it tends to localize the fire – If it is made on the other side of the structure, it may well contribute to the spread of the fire into unburned areas

Good ventilation will lessen the chances of steam burns to firefighters and increase visibility

16

Page 17: VENTILATION

17

Page 18: VENTILATION

Property conservation will occur through good ventilation because the attack team will be able to find and extinguish the fire quicker

It will allow the water fog, smoke, heat, and gases to escape into the environment rather than remain in the structure

All of this will allow better salvage operations while the extinguishment is in process

18

Page 19: VENTILATION

19

Page 20: VENTILATION

Convection will cause the heat, smoke, and gases to travel up to the highest point until they are trapped by a roof or ceiling

As they accumulate, they bank down and spread laterally to involve other areas

This process is called MushroomingMushrooming Ventilation will reduce this effect Fire must be put out quickly though or the

extra air coming in will allow the fire to expand

20

Page 21: VENTILATION

21

Page 22: VENTILATION

Rollover is sudden ignition superheated unburned gases across the ceiling space

Unburned gases gather across the ceiling and when fresh air is supplied the ignite

Proper ventilation on the side of the fire opposite the firefighters will reduce chances of a rollover

22

Page 23: VENTILATION

23

Page 24: VENTILATION

Flashover is the transition between growth and fully developed fires

As original seat of the fire burns, everything else in a room is heated to its ignition temperature

Once reached, the entire room can burst into flames simultaneously with severe consequences to anyone in the room at this time

Ventilation can relieve this as it lets the heat escape before ignition temperatures are reached 24

Page 25: VENTILATION

High heat is available in a structure, but oxygen levels are too low to support combustion

A very dangerous condition exists because the sudden admission of oxygen can cause a sudden ignition called a backdraft

To prevent this, we need to provide vertical ventilation to release trapped heat and flammable products of combustion

25

Page 26: VENTILATION

We need to be aware of this potential and proceed cautiously if conditions are ripe for backdraft

Signs of potential backdraft include: Smoke stained windows Smoke puffing from the building {breathing} Pressurized smoke from cracks in the building Very little flame visible from the exterior Black smoke becoming dense gray yellow Confinement and excessive heat IF ANY are seen, wait on vertical ventilation to be

completed before you try to enter the building

26

Page 27: VENTILATION

We must understand our overall plan of attack before we direct or order ventilation to be started

We must make a series of decisions that pertain to ventilation needs

These decisions should fall into the following order

27

Page 28: VENTILATION

This must be based on the amount of heat, smoke, and gas conditions within the structure, structural conditions, and the life hazards

28

Page 29: VENTILATION

29

Page 30: VENTILATION

This involves knowing construction features of the building, contents, exposures, wind direction, extent of the fire, location of the fire, location of top or vertical openings, and location of cross or horizontal openings

30

Page 31: VENTILATION

Horizontal? Natural or Mechanical?

Vertical? Natural or Mechanical?

31

Page 32: VENTILATION

32

Page 33: VENTILATION

Must use all information available to you to answer this question

Will need input from the people in the structure and those going to the roof

To answer the questions, we have to evaluate several pieces of information and take into account many factors which are covered in the next several slides

33

Page 34: VENTILATION

The danger to human life is our utmost concern

Our first consideration is the safety of firefighters and occupants

Proper ventilation will be needed in conjunction with rescue operations

Dependant on the fire, ventilation may need to happen before rescue operations, or if conditions warrant, fire attack may need to come first – in some cases, both will have to be done at the same time

34

Page 35: VENTILATION

There are also hazards to us as firefighters

The type of building, whether natural openings are adequate, the need to cut through roofs, walls, or floors of varying types, all make the decision process more difficult

35

Page 36: VENTILATION

Some of the expected hazards due to an accumulation of smoke and gases can be:

Obscurity caused by dense smoke Presence of poisonous gases Lack of oxygen Presence of flammable gases Backdraft Flashover

36

Page 37: VENTILATION

We can make some ventilation and tactical decisions as we arrive at the scene based on what visible smoke conditions we have

The density of the smoke is in direct ratio to the amount of suspended particles

The conditions vary according to how burning has progressed

A developing fire and a decaying fire are two totally different fires and must be treated as such

37

Page 38: VENTILATION

An early stage fire will usually give off smoke that is of not much density

If large quantities of carbon particles are present, the smoke may become denser

As the building becomes more involved with fire, the smoke will become denser

38

Page 39: VENTILATION

Building type and design are the initial factors to consider in determining whether to use horizontal or vertical ventilation

Some other factors to consider:

Number and size of wall openings Number of stories, staircases, shafts, ducts,

and roof openings Availability and involvement of exterior fire

escapes and exposures

39

Page 40: VENTILATION

Get in good with the building department so they can let you know when buildings are altered or subdivided

Building permits can reveal information about the heating, ventilating, and HVAC systems and avenues of escape for smoke, heat, and fire gases

Adjoining buildings and how they are attached has a bearing on ventilation

Pre plans can provide valuable information and familiarity with the buildings in your area

40

Page 41: VENTILATION

Basement fires are among the most challenging a firefighter will face

We basically have to descend through the chimney to get to the fire

Access can be by interior or exterior stairs, exterior windows, or hoist ways

Outside entrances may be blocked or secured by iron gratings, steel shutters, wooden doors, or combinations of these for protection from weather and burglars

41

Page 42: VENTILATION

Many buildings have windowless wall areas While they may not be a desirable means of

escape, they are important considerations for ventilation

Windowless buildings create and adverse effect on firefighting and ventilation operations

Ventilation in windowless buildings may be delayed for a long time, allowing the fire to gain headway or to create backdraft conditions

42

Page 43: VENTILATION

Problems in ventilating these building vary depending on the size, occupancy, configurations, and type of material from which the building is constructed

They usually require mechanical ventilation for the removal of smoke

The HVAC system can sometimes clear the smoke by itself

The drawback to this is that it can also spread the fire and it requires electricity to work

43

Page 44: VENTILATION

Depending on time from ignition until firefighters arrive, the fire may have traveled some distance

We must consider the location and extent of the fire when deciding on ventilation

Ventilation before fire location is know may spread the fire into unburned areas

Severity and extent of the fire usually depend on the type of fuel and amount of time it has been burning, installed early warning and fire protection devices, and degree of confinement of the fire

Phase of the fire is a primary consideration

44

Page 45: VENTILATION

Some means of vertical fire extension: Through stairwells, elevators, and shafts by

direct flame contact or by convected air currents

Through partitions and walls and upward between the walls by flame contact and convected air currents

Through windows or other outside openings where flame extends to other exterior openings and enters upper floors {lapping}

45

Page 46: VENTILATION

Some means of vertical fire extension:

Through ceilings and floors by conduction or heat through beams, pipes, or other objects that extend from floor to floor

Through floor and ceiling openings where sparks and burning material fall through to lower floors

By the collapse of floors and roofs

46

Page 47: VENTILATION

The ideal situation is one in which we have prior knowledge of the building and its contents

There is no exact rule except to open the roof “as directly over the fire as possible”

Some of the may factors that will have a bearing on where to ventilate include:

Availability of natural openings such as skylights, ventilator shafts, monitors, and hatches

Location of fire and direction in which the IC wants it to be drawn

47

Page 48: VENTILATION

Some of the many factors that will have a bearing on where to ventilate include:

Type of building construction Wind direction Extent of progress of the fire and the

condition of the building and its contents Bubbles or melting of roof tar Indications of lessening structural integrity of

the roof

48

Page 49: VENTILATION

Some of the many factors that will have a bearing on where to ventilate include:

Effect that ventilation will have on the fire Effect that ventilation will have on exposures Attack crew’s state of readiness Ability to protect exposures prior to actually

opening the building

49

Page 50: VENTILATION

Before ventilating, adequate personnel and fire control equipment must be ready because the fire may increase in intensity once the building is opened

Resources for the involved building and exposures need to be in place

Try to attack the seat of the fire {if safe} immediately after ventilation

Entrance should be made as close to the fire as possible, with charged hoses in place in case of flare up and at critical points of exposure

50

Page 51: VENTILATION

Means opening the roof or existing roof openings for the purpose of allowing heated gases and smoke to escape to the atmosphere

In order to properly ventilate, we must understand the basic types and designs of roofs

Study local roof types and the manner of construction to develop effective vertical ventilation policies and procedures

51

Page 52: VENTILATION

We should be concerned with 3 prevalent types of roof shapes: Flat, Flat, Pitched, and ArchedPitched, and Arched

Buildings may be constructed with a combination of roof designs

Some of the more common styles are the: flat, gable, gambrel, shed, hip, flat, gable, gambrel, shed, hip, mansard, dome, lantern, and mansard, dome, lantern, and butterflybutterfly

52

Page 53: VENTILATION

53

Page 54: VENTILATION

We can undertake vertical ventilation after we have considered the following:

Type of building involved Location, duration, and extent of the fire Observed safety precautions Identified escape routes Selected the place to ventilate Moved personnel and tools to the roof

54

Page 55: VENTILATION

Roof team should be in constant communication with the IC

Responsibilities of the Roof Team Leader:

Ensure that only the required openings are made

Direct efforts to minimize secondary damage Coordinating the crew’s efforts with those of

the firefighters inside the building Ensuring the safety of all personnel who are

assisting in the opening of the building

55

Page 56: VENTILATION

Observe the wind direction with relation to exposures

Work with the wind at your back or side to provide protection while cutting the roof opening

Note the existence of obstructions or excess weight on the roof. These may make operations more difficult or reduce the amount of time before a roof flails.

Provide a secondary means of escape for crews on the roof

56

Page 57: VENTILATION

Exercise care in making the opening so that main structural supports are not cut

Guard the opening to prevent personnel from falling into the building

Evacuate the roof promptly when ventilation work is complete

Use lifelines, roof ladders, or other means to protect personnel from sliding and falling off the roof

Make sure that a roof ladder is firmly secured over the peak of the roof before using it

57

Page 58: VENTILATION

Exercise caution in working around electric wires and guy wires

Ensure that all personnel on the roof are wearing full personal protective equipment including SCBA

Keep other firefighters out of the range of those handling axes and operating power saws

Caution axe users to beware of overhead obstructions within the range of their axe

Make sure that the angle of the cut is not toward the body

58

Page 59: VENTILATION

Start power tools on the ground to ensure operation; however, it is important that the tools be shut off before hoisting or carrying them to the roof

Extend ladders at least five rungs above the roof line and secure the ladder. When using elevating platforms, the floor of the platform should be even with or slightly above roof level

Check the roof for structural integrity before stepping on it; do not jump onto a roof without checking it first

59

Page 60: VENTILATION

Use pre plans and surveys to identify buildings that have roofs supported by lightweight or wooden trusses. Realize that these roofs may fail early into a fire and are extremely dangerous to be on or under

Work in groups of at least two, but not more people than absolutely necessary to get the job done

60

Page 61: VENTILATION

Beware of the following warning signs of an unsafe roof condition:

Melting Asphalt Spongy Roof {a normally solid roof that springs

back when walked upon} Smoke coming from the roof Fire coming from the roof {if it has already

vented itself, we probably do not need to}

61

Page 62: VENTILATION

62

Page 63: VENTILATION

May be found on various types of roofs Almost all of them will be locked or secured in

some manner Scuttle hatches are normally square and

large enough to permit a person to climb onto the roof

They may be metal or wood and generally do not provide an adequate opening for ventilation

Skylights with ordinary glass can be easily shatter, but if they contain wired glass, Plexiglas, or Lexan, they will difficult to shatter and you will do better to attack the framing

63

Page 64: VENTILATION

The sides of a monitor may contain glass or louvers made of wood or metal

Usually have hinged sides that are easily forced at the top

If you cannot remover the top, open at least two sides to create the required draft

Force open stairway doors like you would any door of the same type

It is usually quicker to use one of these openings than to cut a hole in the roof

Drawbacks are their placement and size

64

Page 65: VENTILATION

Pre planning is the best way to learn about the types and construction of roofs in your area

When cutting a roof, one large opening is better than many small ones

Also, try to cut a square or rectangular hole in order to make repairs to the building easier

Power saws are the best equipment for opening roofs, making the work a lot quicker

Safety of the operator and crew are paramount

Pre plans can clue us in as to what equipment we will need to open a specific roof

65

Page 66: VENTILATION

66

Page 67: VENTILATION

Several types of cuts may be used on a roof:

Kerf Cut:Kerf Cut: Basically you just put the saw blade through the roof to look for fire and determine direction of spread

Inspection OpeningInspection Opening:: Make a triangular hole by placing the blade into the roof three times – This can be done when you first get on the roof and as you move away from your point of egress – You are checking for fire under you

67

Page 68: VENTILATION

68

Page 69: VENTILATION

Several types of cuts may be used on a roof:

Louvered Cuts:Louvered Cuts: May be used when cutting through plywood

The cuts are made in between the rafters rather than beside them.

The panels are then hinged on the rafters

69

Page 70: VENTILATION

70

Page 71: VENTILATION

Most commonly found on commercial, industrial, and apartment buildings, {and older homes in Florida}

May or may not have a slight slope for drainage

Frequently pierced by chimneys, vent pipes, shafts, scuttles, and skylights.

May be surrounded and/or divided by parapets, and it may support water tanks, air-conditioning equipment, antennas, and other obstructions to ventilation operations

71

Page 72: VENTILATION

Structurally, they are generally similar to a floor that consists of wooden, concrete, or metal joists covered with sheathing

The sheathing is covered with a layer of waterproofing material and an insulating material

Sometimes, these roofs can be poured reinforced concrete or lightweight concrete, pre-cast gypsum, or concrete slabs se in metal joists

Pre plans, again, will tell us what type of roof it is and what we need to open it

72

Page 73: VENTILATION

These are elevated in the center and form a pitch to the edges

They involve rafters or trusses that run from the ridge to a wall plate on top of the outer wall at the eaves level

The rafters or trusses can be made out of various materials

Sheathing is applied over these, then roofing paper, then shingles or other roof covering

Shingles may be wood, metal, composition, asbestos, slate, or tile

73

Page 74: VENTILATION

On barns, churches, supermarkets, or industrial buildings, you may have roll felt over the sheathing

This can be mopped on with asphalt roofing tar

Instead of wood sheathing, you may find gypsum slabs approximately 2” thick

The incline on these roofs can be very gradual or very steep

Personnel safety is still the main prerogative when venting, take extra precautions as needed

74

Page 75: VENTILATION

Some of these may be easier to get into:

If the roofing material is slate or tile, you may be able to open it with a sledgehammer

Smash the slate or tile, and also the thin lath strips or 1x4’s that they are held up by

Tin roofs can be sliced open and peeled back with tin snips or a large device similar to a can opener

75

Page 76: VENTILATION

One form of this is constructed with bowstring trusses for supporting members

They conceal large un-vented spaces which create dangerous ventilation problems and contribute to the spread of fire and early failure of the roof

WARNING: WARNING: Many firefighters have lost their lives Many firefighters have lost their lives

while a trussed roof has failed. A good while a trussed roof has failed. A good rule to follow is that when a significant rule to follow is that when a significant amount of fire exists in the truss area amount of fire exists in the truss area of a roof structure, firefighters should of a roof structure, firefighters should not be on or under a truss roof.not be on or under a truss roof.

76

Page 77: VENTILATION

Trussless arched roofs are made of relatively short timers of uniform length

This network forms an arch of mutually braced and stiffened timbers

Because it is not a truss, a hole of considerable size may be cut or burned through the sheathing and roofing without causing collapse of the roof structure

Vent them the same as you would other roofs, with safety being an issue because you will not be able to use a roof ladder – Use a ladder truck! ~Mutual Aid~

77

Page 78: VENTILATION

Precast roof slabs are available in many shapes, sizes, and designs

Can be trucked in or built on site These are very difficult to break through and

opening them should be avoided whenever possible

Us natural roof openings and horizontal openings

Popular lightweight materials made of gypsum plaster and Portland cement mixed with aggregates, such as perlite, vermiculite, or sand provided a lightweight floor and roof assembly often referred to as lightweight concrete

78

Page 79: VENTILATION

Lightweight precast planks and slabs are reinforced with steel mesh or rods

The roof is usually finished with roofing felt and a mopping or hot tar to seal it

These roof decks can be poured over permanent form boards, steel roof decking, paper-backed mesh, or metal rib lath

They are relatively easy to ventilate with a hammer head pick, power saw with concrete blade, jackhammer, or other penetrating tool

79

Page 80: VENTILATION

Can be made from several different kinds of metal and constructed in many styles

Light gauge steel roof decks can either be supported on steel frameworks or they can span wider spaces

Corrugated roofing sheets can be made from light gauge cold formed steel, galvanized sheet metal, or aluminum

Light gauge cold formed steel is used primarily for roofs of industrial buildings

These are seldom covered and can be pried from their supports

80

Page 81: VENTILATION

Metal cutting tools or power saws with metal cutting blades must be used

Industrial building usually have adequate natural roof openings, skylights, or hatches

Older buildings may have roofs that are made of large, fairly thin sheets of tin over lath strips

They can be opened by cutting with a power saw, axe, or large sheet metal cutter

81

Page 82: VENTILATION

This is used a little differently than standard ventilation techniques

Trench ventilation is used to stop the spread of fire in a long, narrow structure

It is performed by cutting a large hole {trench} that is at least 4 feet wide and extends from one exterior wall to the opposite one

Usually cut well ahead of the advancing fire for the purpose of setting up a defensive line where the fire’s progress will be halted

Rest of the building is written off82

Page 83: VENTILATION

Without built in vents, the heat and smoke from these fires will quickly spread up into the building

Especially true of balloon frame construction

In balloon frame, fire may go from the basement to the attic without showing anywhere in between

Ventilation of a basement can be accomplished in several ways

If windows are present, horizontal ventilation can be used

83

Page 84: VENTILATION

If no windows are present, you will have to use interior vertical ventilation with natural paths from the basemen, such as stair wells and hoist way shafts

Try to direct this smoke outside on the first floor without spreading it to other portions of the building

The last resort would be to cut a hole in the floor near a first floor window or door to vent the basement, and put a fan in the window / door to draw the smoke out of the building

84

Page 85: VENTILATION

Once vertical ventilation is done, the convection of heated gases creates upward currents that draw the fire and heat toward the opening

Team inside will have better visibility and less contaminates in the air to make their attack easier

You can direct hose streams over the opening to lessen sparks and flying embers

DO NOT direct the stream downward through a ventilation opening as this will upset the orderly movement of gases

85

Page 86: VENTILATION

If the gas movement is upset, it can force super heated air and gases back down on the interior crews causing serious injury or death

It can also contribute to the spread of fire Project your ventilation streams just above the

opening and slightly above the horizontal plane of the roof

They will help cool the thermal column and extinguish sparks and maybe speed the rate of ventilation

86

Page 87: VENTILATION

Factors that can destroy vertical ventilation: Improper use of forced ventilation Excess breakage of glass Fire streams directed into ventilation holes Breakage of skylights Explosions Burn through of the roof, a floor, or a wall Additional opening between the attack team

and the upper opening

87

Page 88: VENTILATION

WARNING:WARNING: NeverNever operate any type of fire stream operate any type of fire stream

through a ventilation hole during through a ventilation hole during offensive operations. This stops the offensive operations. This stops the ventilation process and places interior ventilation process and places interior crews in serious dangercrews in serious danger

Vertical ventilation is not the solution to all ventilation problems because it is sometimes impractical or impossible

You must be able to use all types of ventilation to be effective

88

Page 89: VENTILATION

Venting of heat, smoke, and gases through wall openings such as windows or doors

Structures that lend themselves to horizontal ventilation include:

Residential building where fire has not involved the attic

Involved floors of multistoried buildings below the top floor, or the top floor if attic is uninvolved

Buildings with large, unsupported spaces under the roof where the structure has been weakened by the effects of burning

89

Page 90: VENTILATION

Different procedures are used to horizontally ventilate a room , floor, cockloft, attic, or basement

Procedures will be influenced by the location and extent of the fire

90

Page 91: VENTILATION

Some of the ways of horizontal extension are:◦ Through wall openings by direct flame contact

or by convected air◦ Through corridors, halls, or passage ways by

convected air, radiation, and flame contact◦ Through open space by radiated heat or

convected air currents◦ In all directions by explosion or flash burning of

fire gases, flammable vapors, or dust◦ Through walls and interior partitions by direct

flame contact◦ Through walls by conduction across pipes,

beams or other objects that extend through them

91

Page 92: VENTILATION

This is always an issue in deciding the horizontal ventilation procedure

Wind is an important factor Direction may be designated as

windward {side wind is hitting} or leeward {opposite or downwind side}

If there is no wind, natural horizontal ventilation is less effective because there is not force to remove the smoke

In other cases, exposures on the leeward side can be in severe danger

92

Page 93: VENTILATION

Routing of smoke and heat becomes an issue in horizontal ventilation

We should be aware of internal and external exposures

The routes we use to move the smoke and heated gases can be the same corridors occupants and firefighters will be using

First consideration of horizontal ventilation needs to be the escape routes of the occupants and rescue routes of the firefighters

93

Page 94: VENTILATION

Horizontal ventilation is not accomplished at the highest point in a building, therefore there is the danger that when the rising heated gases are released, they will ignite highest portions of the building

This could be the eaves of this building or an adjacent building, or they may enter a window above the ventilation point

Building should not be opened {unless immediate rescue is needed} until charge lines are in place to attack @ the point where fire might be expected to spread

94

Page 95: VENTILATION

Opening a door or breaking a window on the windward side before the leeward side may pressurize the building and upset the thermal layering

Opening doors and windows between the entry team and the established ventilation exit reduces the intake of fresh air from the opening behind the entry team

95

Page 96: VENTILATION

96

Page 97: VENTILATION

This is accomplished mechanically {fans} or hydraulically {fog streams}

The principal is to move large quantities of smoke and air

Forced ventilation equipment is difficult to classify by a a particular type

Fans can be powered by electric motors, gasoline engines, or water pressure from hose lines

97

Page 98: VENTILATION

Some of the reasons for employing forced ventilation include the following

Ensures more positive control of the fire Supplement natural ventilation Speeds the removal of contaminants,

facilitating a more rapid rescue under safer conditions

Reduces Smoke damage Promotes better public relations

98

Page 99: VENTILATION

Misapplied or improperly controlled forced ventilation can cause a great deal of harm

It requires supervision because of the mechanical force behind it

Some disadvantages are: Introduces air in such great volumes that it

can cause the fire to intensify and spread Depends upon a power source Requires special equipment

99

Page 100: VENTILATION

Oldest of mechanical forced ventilation techniques: uses fans to develop artificial circulation and pull smoke out of a structure

Fan is placed in a window, door, or roof vent hole and they pull the smoke, heat, and gases from inside the building and eject them to the exterior

The fan should be set up to exhaust in the same direction as the wind flow

This will help the wind, speed up the process and supply fresh air to replace what is being removed

100

Page 101: VENTILATION

If natural wind is too light to be effective, you can place fans blowing in on one side and exhausting on the other side

Recirculating air around the fan can be an issue

This can cause a churning effect that reduces efficiency

To prevent this, cover the area around the fan with salvage covers or other materials

Select your desired path and keep it in as straight a line as possible

101

Page 102: VENTILATION

Every corner will cause turbulence and decrease efficiency

Do not open doors or windows near the exhaust fan unless it definitely increases circulation

Remove items such as curtains, drapes, blinds or anything that can reduce airflow

The fans should have explosion proof motors and power cords / connectors

They should be turned off with they are moved

When starting, clear the area of people & loose items

102

Page 103: VENTILATION

Ventilation technique that uses the principle of creating pressure differentials

A higher pressure is created in the build than that outside by using high volume fans

Due to the high pressure inside the building the smoke will seek and outlet to a lower pressure zone through openings controlled by the firefighters

The location where the fan blows in, usually an exterior doorway, is called the point of entry

Place the fan several feet outside the door so that a cone of air covers the entire door opening 10

3

Page 104: VENTILATION

Smoke is ejected from exhaust openings the same size or smaller than the entry opening

Do not open other openings while positive pressure is in use, except the point of exhaust

We can now close doors and windows, pressurizing one room or at a time, in order to speed up ventilation

Additional fans can be placed @ the point of entry to increase the CFM flow and thus the interior pressure

104

Page 105: VENTILATION

If you do not systematically control the exhaust points, the ventilation will work, but it will take a lot longer

When using on multiple floor buildings, the point entry should be at the lowest point.

Smoke can then be systematically removed starting at the floor most charged with smoke {straight out of the book}

It is best to start exhausting at the lowest point and work your way up {experience – if you start in the middle, you will have to do that floor again as smoke from the lower floors will drift up there}

105

Page 106: VENTILATION

PPV requires good fire ground discipline, coordination, and tactics

The main probable is coordinating the opening and closing of doors is stairwells

People may stand with doors to the stairwell or their door open and redirect the PPV away from where you want it

Place a person in charge of the pressurizing process, use radios to make sure it is working properly

106

Page 107: VENTILATION

Take advantage of existing wind conditions Make certain that the cone of air from the

fan covers the entire entry opening Reduce the size of the area being

pressurized to speed up the process by systematically opening and closing doors or by increasing the number of fans

Keep the size of the exit opening in proportion to the entry opening

107

Page 108: VENTILATION

Firefighters can set up PPV without entering the smoke filled environment

PPV is equally effective with horizontal or vertical ventilation because it merely supplements natural ventilation currents

More efficient removal of smoke and heat from a structure or vessel is allowed

The velocity of air currents in a building is minimal and has little, if any, effects that disturb the building contents or smoldering debris. Yet the total exchange of air within the building is faster than using NPV

108

Page 109: VENTILATION

Fan powered by internal combustion engines operate more efficiently in clean, oxygen rich atmospheres

The placement of fans does not interfere with ingress or egress

The cleaning and maintenance of fans used for positive pressure ventilation is greatly reduced compared to that of those used in negative pressure ventilation

109

Page 110: VENTILATION

This is applicable to all types of structures or vessels and is particularly effective at removing smoke from large, high ceiling areas where NPV is ineffective

Heat and smoke may be directed away from unburned areas or paths of exit

110

Page 111: VENTILATION

An intact structure is required

Interior carbon monoxide levels may be increased during use

Hidden fires may {will} be extended

111

Page 112: VENTILATION

May be used where other types of forced ventilation are not being used

It is performed by hose teams inside the fire building

It is used to clear the room or building of smoke, heat, steam, and gases following the initial knockdown of the fire

It takes advantage of the air that is drawn into a fog stream to help pus the products of combustion out of the structure

112

Page 113: VENTILATION

To perform, set a fog stream to wide pattern that will cover 85 to 90 percent of the window or door opening from which the smoke will be pushed out

Nozzle tip should be at least 2 feet from the opening

The larger the opening, the faster the ventilation

There are some drawbacks to using fog streams to perform forced ventilation

113

Page 114: VENTILATION

There may be an increase in the amount of water damage within the structure

There will be a drain on the available water supply. This is particularly crucial in rural firefighting operations where water shuttles are being used

In climates subject to freezing temperatures, there will be an increase in the problem of ice in the are surrounding the building

114

Page 115: VENTILATION

The firefighters operating nozzle must remain in the heated, contaminated space during the operations

The operation may have to be interrupted when the nozzle team has to leave the area for some reason {SCBA, Rehab, Etc.}

115

Page 116: VENTILATION

Most modern building have HVAC systems These systems can contribute to fire and

smoke spread throughout a building Pre plans should include information on the

systems design and use along with diagrams of the duct system and fire protection within

We should know the location and operation of the controls that will manually shut down the system when so desired

System may draw heat and smoke in, so always check the duct work and areas around it for extension

116

Page 117: VENTILATION

Remember, this system will need to be ventilated before it is restarted

In large buildings or where large numbers of people are present, the building may have a smoke control system

They involve the mechanical systems, doors, partitions, windows, shafts, ducts, fan dampers, wire controls, and pipes

We should know about these in our pre plans We should not try to operate them due to

their differences and complexity. Call the occupants.

117

Page 118: VENTILATION

Typical high rise occupancies are hospitals, hotels, apartments, and office buildings

All these equal a lot of people in danger in a fire

Fire and smoke may spread rapidly through pipe shafts, stairways, elevator shafts, air-handling systems, and other vertical openings

These openings cause a stack effect {natural, vertical heat and smoke movement throughout a building} creating an upward draft and interfering with evacuation and ventilation

118

Page 119: VENTILATION

Layering of smoke and gases on floors below the top floor of un-vented multi-story buildings is possible

These gases travel up until their temperature is reduced to the same as the surrounding air

When this happens, the smoke and gases will mushroom on this floor or in this area

The layering of smoke at an area of temperature equalization is called stratification

Pre plans should include tactics and strategies to deal with this problem in tall buildings

119

Page 120: VENTILATION

High rise ventilation must be carefully coordinated to ensure the effective use of personnel, equipment, and extinguishing agents

Personnel demand will be approximately 4 to 6 times what it is for a normal house fire

Consider using horizontal ventilation @ stratification level

SCBA and extra bottles will be in great demand

Communication and coordination among teams will become more difficult due to the number of people on the scene 12

0

Page 121: VENTILATION

Top ventilation must be considered during pre planning

Often, in these buildings, only one stairwell goes to the roof

We must know which one so we can use this as a chimney to ventilate the building

Block this door open or take it off its hinges before you begin opening the interior stairwell doors

121

Page 122: VENTILATION

Failure to open / secure this door can result in the stairwell becoming filled with superheated fire gases and smoke

Elevator shafts may also penetrate the roof line and may be used for ventilation

Using stairwells or elevator shafts for evacuations and ventilation simultaneously is potentially life-threatening

122

Page 123: VENTILATION

Failure to open / secure this door can result in the stairwell becoming filled with superheated fire gases and smoke

Elevator shafts may also penetrate the roof line and may be used for ventilation

Using stairwells or elevator shafts for evacuations and ventilation simultaneously is potentially life-threatening

123

Page 124: VENTILATION

8-1.3 Demonstrate opening various types of windows from inside and outside, with and without fire department tools.

8-1.4 Demonstrate breaking windows or door glass, and removing obstructions.

8-1.5 Demonstrate ventilation of a floor or roof using an axe.

8-1.6 Demonstrate ventilation using a water fog stream.

124

Page 125: VENTILATION

8-2.1 Demonstrate the use of different type of power saws and jack hammers.

8-2. Demonstrate the techniques for ventilating different types of roofs.

8-2.4 Demonstrate the removal of existing roof opening. I.e.: skylights, scuttle covers, and other roof openings.

8-2.5 Demonstrate the different types of equipment used for forced ventilation.

125

Page 126: VENTILATION

8-3.1 Demonstrate natural and mechanical methods for horizontal ventilation.

8-3.2 Demonstrate natural and mechanical methods for vertical ventilation.

126

Page 127: VENTILATION

127