238
Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B, 5052, 5053) Operating Manual, Software V03.0 01/07

Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Embed Size (px)

Citation preview

Page 1: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Vehicle Diagnostic, Testing and Information SystemsVAS 505x (5051, 5051B, 5052, 5053)

Operating Manual, Software V03.0 01/07

Page 2: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Contents

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.IA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Contents

Safety Instructions ............................................................................................................ iIMPORTANT SAFETY INSTRUCTIONS ........................................................................ ii

1 General Information ...........................................................................................1-11.1 General Notes ..................................................................................................1-1

1.2 Safety instructions ............................................................................................1-21.3 Differences within the tester series ..................................................................1-2

1.3.1 Operating modes ................................................................................1-2

1.3.2 Testers with and without Test Instruments .........................................1-31.3.3 VAS 5053: administration via partner application ...............................1-3

1.4 Other applicable documents ............................................................................1-3

2 Initial startup .......................................................................................................2-12.1 Enter workshop code .......................................................................................2-2

2.1.1 Equipment number ..............................................................................2-3

2.1.2 Importer number and dealership number ............................................2-32.1.3 Dealership identifier ............................................................................2-5

2.2 Changing the dealership identifier ...................................................................2-6

2.3 Date/Time ........................................................................................................2-62.3.1 Setting the date ...................................................................................2-7

2.3.2 Setting the time ...................................................................................2-7

2.3.3 Accepting the date/time ......................................................................2-82.4 Back to the start screen ...................................................................................2-9

2.5 Installing brand data from CDs ......................................................................2-10

2.6 Installation of additional applications .............................................................2-112.7 Printer ............................................................................................................2-12

3 Operation of the masks ......................................................................................3-13.1 Masks ...............................................................................................................3-23.2 Buttons .............................................................................................................3-2

3.3 Work window ....................................................................................................3-2

3.3.1 Left and right information window .......................................................3-33.3.2 Dialog box ...........................................................................................3-5

Page 3: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Contents

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.IIA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.3 Selection bar .......................................................................................3-6

3.3.4 Scroll bar .............................................................................................3-63.3.5 Cursor .................................................................................................3-7

3.3.6 Navigation bar .....................................................................................3-8

3.3.7 Slide controls ....................................................................................3-103.3.8 Using the virtual keyboards ...............................................................3-10

3.3.8.1 Alphanumeric keyboard ................................................................3-11

3.3.8.2 Numeric keyboard .........................................................................3-133.3.8.3 Decimal keyboard .........................................................................3-14

3.3.8.4 Hexadecimal keyboard .................................................................3-15

3.3.8.5 Virtual keyboard for applications / installations .............................3-163.4 USB keyboard and mouse .............................................................................3-17

3.4.1 USB keyboard ...................................................................................3-17

3.4.2 USB mouse .......................................................................................3-173.5 Print ................................................................................................................3-18

3.5.1 "Print/Save" dialog box .....................................................................3-19

4 Vehicle Self-Diagnosis/OBD ..............................................................................4-1

5 Test Instruments .................................................................................................5-15.1 Overview ..........................................................................................................5-1

5.1.1 Printing measured values ...................................................................5-15.2 Starting the Test Instruments ...........................................................................5-2

5.3 Multimeter ........................................................................................................5-3

5.3.1 Direct and Alternating Voltage Measurement .....................................5-55.3.2 Direct and alternating current measurement in-line ............................5-7

5.3.3 Direct and Alternating Current Measurement via Current Pick-up ......5-8

5.3.4 Resistance Measurement ...................................................................5-95.3.5 Continuity Test ..................................................................................5-10

5.3.6 Diode Test .........................................................................................5-12

5.3.7 Voltage DSO1 ...................................................................................5-145.3.8 Pressure T/D .....................................................................................5-15

5.3.9 Temperature T/D ...............................................................................5-16

5.3.10 Calibrate ............................................................................................5-175.4 Digital Storage Oscilloscope (DSO) ...............................................................5-18

Page 4: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Contents

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.IIIA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

5.4.1 Channel A, Channel B ......................................................................5-20

5.4.2 Measuring mode ...............................................................................5-255.4.3 Trigger Mode .....................................................................................5-27

5.4.4 Bandwidth limiting (VAS 5051B only) ...............................................5-30

5.4.5 Freeze Frame ...................................................................................5-305.4.5.1 Freeze frame with one measurement cursor displayed ................5-31

5.4.5.2 Freeze frame with measurement cursor 1 and measurement cursor 2 displayed ...........................................5-32

5.4.6 Long-term measurement in draw mode ............................................5-34

5.4.7 Tips and Information .........................................................................5-38

5.5 Parallel mode with Test Instruments and Vehicle Self-Diagnosis ..................5-405.5.1 Overview ...........................................................................................5-40

5.5.2 Operation ..........................................................................................5-41

5.5.3 Values of "Final control diagnosis" diagnostic function .....................5-435.5.4 Values of the "Read measured values block" and "Basic settings" diag-

nostic functions ..................................................................................5-44

5.5.5 Values of "OBD" operating mode ......................................................5-44

6 Guided Fault Finding ..........................................................................................6-16.1 Overview ..........................................................................................................6-1

6.2 Start Guided Fault Finding ...............................................................................6-76.3 "Go to" destination menu .................................................................................6-8

6.4 Vehicle identification ........................................................................................6-9

6.4.1 Vehicle without CAN diagnostics ......................................................6-106.4.2 Vehicle with gateway and CAN diagnostics ......................................6-10

6.4.2.1 Gateway not registered .................................................................6-11

6.4.2.2 No communication with gateway ..................................................6-126.5 Confirming vehicle identification, diagnostic connection ................................6-13

6.6 Vehicle system test ........................................................................................6-15

6.6.1 Possible problems .............................................................................6-166.6.1.1 Diagnostic bus faulty .....................................................................6-16

6.6.1.2 Definitely installed control unit not recognised ..............................6-17

6.6.1.3 Optionally installed control unit not recognised ............................6-176.6.2 Observe vehicle system test .............................................................6-18

6.6.3 Start module ......................................................................................6-19

Page 5: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Contents

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.IVA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

6.7 Fault memory contents ..................................................................................6-20

6.8 Complaint report ............................................................................................6-256.9 Function/Component selection ......................................................................6-30

6.9.1 Documents ........................................................................................6-34

6.10 Test plan ........................................................................................................6-366.11 Function test ..................................................................................................6-39

6.11.1 Test dialogs .......................................................................................6-43

6.11.2 Measuring instruction (multimeter) ....................................................6-436.11.3 Measuring instruction for vehicle systems ........................................6-45

6.11.3.1 Measuring instruction results in a message ..................................6-45

6.11.3.2 Measuring instruction with direct output .......................................6-466.11.3.3 Measured values table ..................................................................6-46

6.11.4 Digital Storage Oscilloscope (DSO) measuring instruction ...............6-49

6.11.5 Cancel function test ..........................................................................6-496.12 Leaving the Guided Fault Finding application ................................................6-50

6.12.1 Interrupt .............................................................................................6-51

6.12.1.1 Interrupt work briefly (pause) ........................................................6-516.12.1.2 "Interrupt" work for a longer period (save job) ..............................6-52

6.12.1.3 Load diagnosis job ........................................................................6-53

6.12.2 Cancel ...............................................................................................6-556.12.3 Exit ....................................................................................................6-55

6.13 Diagnosis log .................................................................................................6-57

6.14 Function test log .............................................................................................6-586.15 Stop modul .....................................................................................................6-58

6.16 On-line feedback log ......................................................................................6-59

7 Guided Functions ...............................................................................................7-17.1 Overview ..........................................................................................................7-1

7.2 Guided Functions run sequence ......................................................................7-5

8 Applications ........................................................................................................8-18.1 Overview ..........................................................................................................8-1

8.2 Starting application ..........................................................................................8-1

8.2.1 Starting application from CD-ROM .....................................................8-38.2.2 Service training ...................................................................................8-3

Page 6: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Contents

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.VA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9 Administration ....................................................................................................9-19.1 Overview ..........................................................................................................9-19.2 Starting Administration .....................................................................................9-3

9.3 Selecting function .............................................................................................9-4

9.4 Install update ....................................................................................................9-59.4.1 Base CD ..............................................................................................9-6

9.4.1.1 Loading a base CD .........................................................................9-7

9.4.2 Update base CD .................................................................................9-79.4.2.1 Loading an update base CD ...........................................................9-7

9.4.3 Brand CD ............................................................................................9-8

9.4.4 Flash CD .............................................................................................9-89.5 Net-update .......................................................................................................9-9

9.6 Self-test ..........................................................................................................9-11

9.6.1 Test Instruments unit (VAS 5051 / VAS 5051B only) ........................9-129.6.2 Diagnostic bus unit ............................................................................9-12

9.7 Enter Workshop Code/Change Dealership Identifier .....................................9-14

9.8 Signal Generator ............................................................................................9-159.9 Date/Time ......................................................................................................9-16

9.10 Expanded Functions ......................................................................................9-16

9.11 Select Initial Graphic ......................................................................................9-169.12 Contents .........................................................................................................9-16

9.13 Print Format ...................................................................................................9-17

9.13.1 Printer driver / Paper format ..............................................................9-179.13.2 Print type ...........................................................................................9-18

9.13.3 Changing printer properties ..............................................................9-18

9.14 Print jobs (VAS 5053) ....................................................................................9-199.15 Touch Screen Calibration ..............................................................................9-20

9.16 ESIS Installation or Update ............................................................................9-22

9.17 Installation or update assist (not VAS 5051) ..................................................9-229.18 Display user documentation ...........................................................................9-23

9.18.1 Displaying a document on the VAS 5051 .........................................9-24

9.18.1.1 Zoom .............................................................................................9-249.18.1.2 Original size ..................................................................................9-25

Page 7: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Contents

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.VIA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.18.1.3 Backward ......................................................................................9-25

9.18.1.4 Forward .........................................................................................9-259.18.1.5 Print ..............................................................................................9-25

9.18.1.6 Operating bar ................................................................................9-26

9.18.2 Displaying a document on the VAS 5052, VAS 5051B,(VAS 5053) ........................................................................................9-27

9.18.3 Viewing and printing user documentation on a PC ...........................9-27

9.19 Activate/deactivate telediagnosis ...................................................................9-289.19.1 Telediagnostics (waiting) ..................................................................9-28

9.19.2 Telediagnosis (RSIS) ........................................................................9-31

9.20 ELSA installation ............................................................................................9-339.21 ELSA administration ......................................................................................9-33

9.22 Application statistic ........................................................................................9-34

9.23 Installation applications ..................................................................................9-359.24 Dimension pressure / temperature .................................................................9-35

9.25 Network settings ............................................................................................9-36

9.25.1 Display network settings ...................................................................9-379.25.2 Change CentralPartnerNet-password ...............................................9-37

9.25.3 Adjustusting station name .................................................................9-37

9.25.4 Displaying target-URL .......................................................................9-389.25.5 Activate/Deactivate online connection via the

Internet (Secure Client) .....................................................................9-39

9.25.6 Proxy settings ...................................................................................9-399.25.7 GeKo-test (confidentiality and component protection) ......................9-40

9.25.8 Setting ISDN protocol .......................................................................9-40

9.25.9 Installation radio LAN ........................................................................9-419.25.10 Online-connection .............................................................................9-41

9.25.11 Importing importer settings ...............................................................9-42

9.25.12 Application tests ...............................................................................9-429.25.13 Activating/deactivating network update after restart .........................9-42

9.26 Exporting function test files ............................................................................9-43

9.27 Import function test files .................................................................................9-439.28 System expansions ........................................................................................9-44

9.28.1 Add printer ........................................................................................9-44

Page 8: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Contents

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.VIIA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.29 Keyboard assignment ....................................................................................9-45

9.30 Update installation (only VAS 5053) ..............................................................9-459.31 Battery service ...............................................................................................9-46

9.32 Display battery charging ................................................................................9-47

9.33 Switching on erWin documents (only VAS 5051B and VAS 5052) ................9-489.34 Partner application (VAS 5053) .....................................................................9-48

9.35 Configuration of vehicle communication ........................................................9-49

10 Help ....................................................................................................................10-110.1 Overview ........................................................................................................10-1

10.2 Starting and closing Help ...............................................................................10-1

10.3 Help Overview ................................................................................................10-210.4 Help on pressed button ..................................................................................10-4

11 Abbreviations and terms .................................................................................11-1

12 Index ..................................................................................................................12-1

Page 9: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Contents

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.VIIIA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Applicable software versions

This operating manual applies to base CD release V11.00.

Associated documents

In addition to this operating manual that describes the use of the individual ➚operating modes, the following relevant technical documents may exist for the individual testers:

• /1/ Start-up/unpacking instructions (tester-specific)with important information about starting up and registering the unit.

• /2/ Brief instructions (tester-specific)Fold-out sheet with information about the tester and also brief information about using it. This printed documentation is a part of a tester package.

• /3/ Operating Manual VAS 505x Hardware (tester-specific)Description of tester, display and control elements, functions of diagnostic and meas-urement cables, troubleshooting as well as technical data.

• /4/ Start-up/unpacking instructions including partner application VAS 5053Describes, in addition to /1/, the installation of the partner application and also admin-istration functions for the VAS 5053.

• /5/ Printer manual The documentation for the printer is included in the printer package (also see the ac-companying data carrier).

• /6/ VAS 505x Service information contains important information, addresses and telephone hotlines in case of malfunc-tion.

• /7/ Vehicle self-diagnosis operating manualDescribes the use of the "Vehicle self-diagnosis" operating mode.

Reference may be made to these documents in the operating manual as follows. Example: (See /3/, chapter "Troubleshooting")

NoteThe operating manuals are subject to maintenance and are delivered with every base CD, with the exception of /2/ and /5/. Check the manuals from time to time to see whether there are any updates. You can find information on the display of the manuals in section 9.18.

Page 10: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Safety Instructions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.iA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Safety Instructions

Meaning of symbols

The safety instructions in the operating manuals, the Startup/Unpacking Instructions or in other documentation provided, on screen displays on the tester during operation and on the products themselves use symbols with the following meanings:

The WARNING symbol warrants particular attention for your safety.

The Caution symbol tells you that if the information is ignored, damage to the vehicle and/or the tester could result (e.g.: Ensure that the touch screen is not touched with sharp, edged objects.).

A Note symbol contains other, special instructions for using the device, and related information.

Warning!Text with this symbol contains information for your safety and how you can reduce the risk of severe or fatal injury.

Caution!Text with this symbol contains information about how you can avoid damage to the vehicle and the tester.

NoteText with this symbol contains additional, useful information.

Note on further safety instructionsThe general safety instructions, which are valid for the complete VAS 505x family of testers, are listed in the following. Further safety instructions are to be found in the operating manuals. Therefore, please read the operating manuals before use.Safety instructions may also appear on the screen of the tester. Follow all the instructions displayed.

Page 11: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Safety Instructions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.iiA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

IMPORTANT SAFETY INSTRUCTIONS

1. Warning!Read all instructions.

2. Warning!Do not operate equipment with a damaged cord or if the equipment has been damaged - until it has been examined by a qualified serviceman.

3. Warning!Do not let cord hang over edge of table, bench or counter, or come in contact with hot manifolds or moving fan blades.

4. Warning!An extension cord is not allowed. For testing use only specified cables.

5. Warning!Always unplug equipment from electrical outlet when not in use. Never yank cord to pull plug from outlet. Grasp plug and pull to disconnect.

6. Warning!To protect against risk of fire, do not operate equipment in the vicinity of open containers of fuel (gasoline).

Page 12: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Safety Instructions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.iiiA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

7. Warning!Adequate ventilation should be provided when working on operating combustion engines.

8. Warning!Use only as described in this manual. Use only manufactures’s recommended attachments.

9. Warning!Risk of explosionsThe devices have internal parts which emit sparks and therefore must not be exposed to flammable fumes. The device should be operated at least 460 mm (18 inches) above the floor surface since fumes from fuels and other materials accumulate at floor level.

10. Warning!All measurement cables may only be used within the measurement ranges stipulated in the technical specifications and the descriptions in the operating manual. All measurement pick-ups may only be used on cable whose casing is undamaged. Do not carry out measurements on damaged cables.

11. Warning!The devices connected to electrical power supply correspond to protection class 1 and are fitted with a safety-tested mains cable. They may only be connected to electrical networks with an earthed protective conductor (TN networks) or electrical outlets with earthed protective conductors.

12. Warning!Fluctuations and deviations in the power supply beyond the permitted range of tolerance can lead to malfunctions and damage.

Page 13: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Safety Instructions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.ivA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

13. Warning!During test drives, secure the tester with a strap on the vehicle's back seat and connect it to the vehicle using the diagnostic cable. A second person must operate the tester from the back seat. Operation from the front seat is too dangerous, e.g. in the event of airbag activation.

Only for VAS 5051:To supply the VAS 5051 with power from the vehicle battery, use only the 3 m diagnostic cable.

14. Warning!Electrical ignition systems carry voltages of up to approx. 30 kV. Observe general safety guidelines for workshops at all times.

15. Warning!If you open the tester or its accessories without authorisation or carry out improper alterations to them, considerable risk to you and to the device may result.

16. Caution! VAS 5051 - changing fuseFor inline current measurements with the VAS 5051, only a replacement fuse of the same type and same amperage may be installed in order to avoid risks of fire and to protect the device. To order original parts, refer to the corresponding chapters of the operating manual.

17. Caution! VAS 5051B workshop trolley - ventilationWhen operating with the VAS 5051B workshop trolley, make sure that there is sufficient ventilation for the table power adapter of the tester and for the printer. Please note that even when the tester is switched off, the battery charging circuit remains in operation and the printer is online (although in energy saving mode).• Completely open the top cover above the printer or the roll-up door during operation

(depending on the existing workshop trolley).• Heat-dissipation of the table power adapter must not be impaired by objects on top

of it (cable, cloth, etc.).• Pull the mains cable of the workshop trolley to switch off the complete device.

Page 14: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Safety Instructions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.vA5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

SAVE THESE INSTRUCTIONS!

Release: 2005-03-30

18. Caution! when connecting non-VW vehiclesThe VAS 505x diagnostic devices were developed for vehicles from the Volkswagen group. If the tester is connected directly to vehicles from other manufacturers, damage to the vehicle could result.Therefore if non-VW vehicles are to be tested using the general OBD functions in the Vehicle Self-Diagnosis application, the OBD adapter cable VAS 5052/16 needs to be connected between the diagnostic cable and the diagnostic connection on the vehicle (with fewer cable connections).

19. Caution! when handling the battery• The battery may only be replaced by trained personnel.• Never short-circuit the battery.• Never throw the battery into a fire.• Dispose of or recycle the battery in accordance to the local regulations.

Page 15: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

General Information

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.1-1A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

1 General Information

1.1 General Notes

The operating manual software contains the information you will need to operate the tester series VAS 505x, as far as use of the ➚operating modes1 via the touch screen is concerned.

All information about the tester/hardware can be be found in /3/.

This documentation is intended to be used by technically qualified persons with the rele-vant knowledge in the field of vehicle diagnosis and test instruments.

For reasons of clarity the operating manual does not include all details of all versions of the operating modes described. In the same way the contents of the ➚masks shown here may differ to a minor extent from the masks shown by the different tester types.

Tester-specific differences are indicated by text and / or symbols. The model designation "VAS 505x" stands for VAS 5051, VAS 5051B, VAS 5052 and VAS 5053.

The symbols of the corresponding testers appear at the top of pages containing informa-tion valid for several models.

1. The glossary arrow ➚ indicates that the term so marked is explained in chapter 11.

Table 1-1 Tester symbols

VAS 5051 VAS 5052

VAS 5051B VAS 5053

VAS 5051

VAS 5052

VAS 5051B

VAS 50 53

Page 16: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

General Information

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.1-2A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

1.2 Safety instructions

You should comply with all safety instructions. These will be found after the table of con-tents and at the various relevant places in the operating manual.

1.3 Differences within the tester series

1.3.1 Operating modes

The following table provides an overview of operating modes available in the different testers.

� available, ❍ not available◗ available in part at the tester, in part via the ➚partner application

Communication with LT3 commercial vehicles and UDS control units

Communication with LT3 vehicles is available as a new feature from base CD V10.00 and with UDS control units from base CD V11.00.

Table 1-2 VAS 505x Operating modes

Operating mode VAS 50511

1. For the VAS 5051, there is no communication with LT3 and ⁄UDS control units atpresent.

VAS 5051B

VAS 5052

VAS 5053

Administration � � � ◗

Vehicle Self-Diagnosis � � � �

OBD � � � �

Test Instruments � � ❍ ❍

Guided Fault Finding � � � ❍

Guided Functions � � � �

Applications � � � ❍

Page 17: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

General Information

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.1-3A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

1.3.2 Testers with and without Test Instruments

Within the tester series there are models with and without Test Instruments. For the cor-rect use of the function tests with test instruments available in the Guided Fault Finding, so-called "replacement values" (see section 6.11) must be input via a ➚virtual keyboard in the case of testers without Test Instruments. The measurements are carried out using an external test instrument and the measured values then input via the touch screen.

1.3.3 VAS 5053: administration via partner application

Instead of a hard disc, the VAS 5053 is equipped with a flash (memory) card. It does not have a DVD drive either. This means that some Administration functions cannot be carried out on the VAS 5053 directly. They are therefore 'boarded out' and executed from a part-ner application (see /4/). The communication between the partner (VAS 5051B, VAS 5052 or workshop PC) and the VAS 5053 is carried out via a USB connection.

1.4 Other applicable documents

Associated documents are listed after the table of contents. Please note that each tester has its own hardware description. The software description, on the other hand, since it nearly applies to the entire VAS 505x tester series, is provided in a common operating manual.

Using the operating manuals

The operating manuals are located on the ➚base CD and are loaded onto the tester via the CD. You can also view and print the operating manual if you insert the base CD into the CD/DVD drive of a PC. For more detailed information, see section 9.18.

Caution!Only insert the base CD in a PC that has already been switched on, and remove it from the CD/DVD drive again without delay after you have viewed the operating manual. Since the base CD can be booted, the operating system on your PC's hard drive can be destroyed if the base CD is still in the drive the next time the PC is switched on.

Page 18: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-1A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

2 Initial startup

Once the tester has completed the start-up routine, initially a warning will be displayed:

No network communication is possible with the current station name!

Use the menu item Administration / Network settings to change the station name.

This message will appear at every start-up until you change the station name. For infor-mation on how to define this setting, see section 9.25.3.

Click on OK to close this dialog box.

Another dialog box now appears. It appears each time the tester is started. It explains the meaning of the symbols used for warnings and notes. After reading the information, close the dialog box with OK. You can access the global warnings and notes at any time by clicking on the button with the red warning triangle (see fig. 2-1).

Depending on the tester battery's state of charge on the VAS 5051B and VAS 5053, a prompt may appear asking you to start a battery service cycle. For more information, see section 9.31.

Closing the dialog boxes enables the start mask. It contains the initial graphic, the current software version of the base CD and the buttons ➚Administration, Warning and notes, Help and Print. The image you see may vary depending on the software version. For information on using the buttons, see chapter 3.

Fig. 2-1 Start mask as it appears during initial startup

Information on the currently loaded base CD is shown here

Press this button to open Administration.

Printouts, help, warnings and notes, indication of date and time

Page 19: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-2A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

2.1 Enter workshop code

Before you can use the tester in your workshop, you must first enter your workshop code. To do this, you can use the Enter Workshop Code function. This function only appears when you start the device for the first time.

To enable worldwide equipment identification and a unique user assignment, three ele-ments are used:

• Equipment number• VZ / importer number1

• Dealership number

The VZ / importer number and dealership number (provided by Volkswagen) must be input by the user at initial start-up. To do so, first click on the Administration button and then select the line "Enter workshop code".

Fig. 2-2 Mask Administration, select function

1. VZ: Sales centre in Germany

Select this function!

Entered by manufacturer

Page 20: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-3A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

2.1.1 Equipment number

The equipment number (the same as the last five digits of the ser. number on the rating plate) is held in the read-only memory in the unit and cannot be changed by the user (see fig. 2-2).

2.1.2 Importer number and dealership number

Two entry masks will appear so that you can enter the workshop code (importer number and dealership number). These masks will only appear once. Another mask will then appear, allowing you to enter the dealership identifier as shown in table 2-2. You can change this entry at any time.

Table 2-1 Equipment numbers

Range of numbers

Model

1 - 19999 VAS 5051

20001 - 49999 VAS 5053

50001 - 79999 VAS 5052

80001 - 99999 VAS 5051B

Table 2-2 Workshop code

Parameter Type of input

Importer number three digits from 0 to 9 (number is provided by VW)

Dealership number five digits from 0 to 9 (number is provided by VW)

Dealership identifier you can enter up to two lines, each containing a maxi-mum of 60 numbers and letters, for the name and address of your workshop; entries must be in Latin letters with no diacritical marks

Page 21: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-4A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Fig. 2-3 Mask "Enter importer number"

For information on using the ➚virtual keyboards, see also section 3.3.8.

Fig. 2-4 Mask "Enter Dealership Number"

The workshop code that has been entered remains unchanged even after installing a new ➚base CD (see section 9.4) and once entered can never be changed.

Enter your 3-digit importer number and confirm by pressing Q.

Corrections:press C to delete the rightmost digit in the display.

Enter your 5-digitdealership number and confirm by pressing Q.

Page 22: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-5A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Fig. 2-5 "Confirmation of input for importer number and dealership number" mask

2.1.3 Dealership identifier

After you have confirmed the entries for the importer number and dealership number, a mask will appear so that you can enter the dealership identifier.

Fig. 2-6 Keyboard used for entering dealership identifier

Make sure that the entries you have made are correct. Select Cancel to enter the information again.

Note:It is not possible to change a workshop code after it has been entered!

Page 23: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-6A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Enter your dealership identifier (such as company name and address) here line by line. Conclude the input of each line using the white "Q" button (not with the grey letter but-tons). Use the white arrow button to switch between lower and upper case letters. The other arrow keys may be used for changing the input position.

For more information on using the virtual keyboard, see section 3.3.8.

2.2 Changing the dealership identifier

After you have entered the workshop code, the function "Enter workshop code" is replaced by "Change dealership identifier". With this function, you can change your dealership identifier at any time.

2.3 Date/Time

After entering the workshop code, you can change to Administration operating mode to set the correct date and time for the system. Select "Date/time" in the list to display the following mask:

Fig. 2-7 Mask "Date/Time", set hour

Once the date/time has been set, it can only be overwritten again under specific circum-stances (see section 2.3.3).

The arrows appear after touching a button.

Page 24: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-7A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

2.3.1 Setting the date

The date is displayed according to the German standard: day - month - year. To change the date, select the display field for the day, the month or the year. The appropriate value can be set individually using the two arrow keys to the left and right of the date display.

2.3.2 Setting the time

To change the time, select the display field for the hour or the minute. The appropriate value can be set individually using the two arrow keys to the left and right of the time display.

The left-hand knob decrements the selection by one unit.

The right-hand knob increments the selection by one unit.

The left-hand knob decrements the selection by one unit.

The right-hand knob increments the selection by one unit.

Page 25: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-8A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

2.3.3 Accepting the date/time

By pressing "Go to", you can "Cancel" or "Exit" the time input and exit the mask without changing the system time.

NoteA set date/time is stored on the tester and updated continuously from this point forward. Values before the date last saved are not accepted. If you attempt to store an older date, an appropriate message is displayed.In this case, the date can only be reset after the reinstallation of a formatting base CD (e.g. Base V07.00.00).

Press "Back" to return to the previous screen mask. The set val-ues are used as the system date/time. The current time values are always displayed again on the navigation bar at the bottom of the work window.

Page 26: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-9A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

2.4 Back to the start screen

With the Go to button and subsequent selection of the Exit line you can return to the start screen from the Administration operating mode.

Now the tester is ready for operation and displays e. g. the following start screen with other activated buttons.

Fig. 2-8 Start mask after entering the dealer data

The current version of the base CD is shown in the start mask. Included in this informa-tion are the language designation, version number and version date.

The start screen offers you the following selection:

• ➚Vehicle Self-Diagnosis, see /7/• ➚OBD, see /7/• ➚Test Instruments, see chapter 5 (Replacement value input for VAS 5052)• ➚Guided Fault Finding, see chapter 6• ➚Guided Functions, see chapter 7• ➚Applications, see chapter 8• ? (Help), see chapter 10• (safety information), see section 3.3.6• Print; see section 3.5 and the corresponding sections of the operating modes in

question• ➚Applications; see chapter 8 (not VAS 5053)

Page 27: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-10A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

2.5 Installing brand data from CDs

For Guided Fault Finding (not with VAS 5053) and Guided Functions to work, you must install one or more ➚brand CDs as follows:

1. Open the CD / DVD drive and insert the desired brand CD. Be sure to read the infor-mation about inserting CDs (see /3/).

2. Close the CD drive.3. Press Administration. 4. In the mask that appears, choose "CD update/installation" from the menu (fig. 2-9.

For more information about this function, see section 9.4). Confirm the security dialog that follows.

5. The contents of the brand CD are now installed on the VAS 505x. It can take more than an hour to carry out a full installation. As soon as installation is complete, the test-er switches from Administration operating mode back to the start mask. A brand sym-bol is displayed in the top right corner of the screen to indicate which brand CD(s) have been installed on the tester.

Fig. 2-9 Installing a brand CD

Page 28: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-11A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Fig. 2-10 Start mask with brand symbol after installation of brand CD

6. Remove the CD from the drive. Install additional CDs if necessary by repeating steps 1 through 6.

For installation on the VAS 5053 via the ➚partner application, see /4/.

2.6 Installation of additional applications

The installation of additional applications, such as e.g. ELSA, erWin, Bentley-Assist or ESIS, is described in the administration (see chapter 9).

After the installation, an appropriate button, e.g. "Elsa Win", appears in the start mask, above the "Applications" button.

Two brand CDs are loaded

Page 29: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Initial startup

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.2-12A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

2.7 Printer

On/Off switch (VAS 5051/VAS 5051B printer)

If the on/off switch on the left side of the printer is off, switch it to ON. You will see the message "INITIALIZING" in the display field while it is starting up. Once operationally ready, the printer switches to display "ON-LINE..." and the "Ready" LED next to the dis-play panel lights up.

The printer can remain on because it switches automatically to standby mode.

NoteFor information about printers and possible settings, see section 9.13 and section 9.28.1.

NoteWhen a print job is started, standby mode is automatically canceled and the internal heating element is switched on. When the operating temperature is reached (after approx. 60 s) printing begins.

Page 30: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-1A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3 Operation of the masks

Fig. 3-1 Overview – masks

1. ➚Mask (screen display)2. Button in the navigation bar3. ➚Work window4. Left and right ➚information window5. ➚Dialog box6. ➚Selection bar7. ➚Scroll bar8. Cursor9. ➚Navigation bar

NoteIn "Vehicle self-diagnosis" operating mode, the use of the masks may differ from this description. For more information about the operation of the vehicle self-diagnosis, see /7/.

2

3

4

8

5

67

9

4

1

Page 31: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-2A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.1 Masks

The graphic displays on the screen are known as "masks" (fig. 3-1, 1). They display all the information and control functions.

The masks displayed on the tester are usually structured in the same way: in the bottom section there is a bar with control elements (the ➚navigation bar), the middle and largest section is taken up by the work window in which you make your selection or can enter val-ues. The two information windows are above the work window.

3.2 Buttons

In each mask, you will only see the buttons (fig. 3-1, 2) that are necessary for a particular task. You select the various functions with these buttons. The colour of the button shows you whether or not it is activated. If the button is dark it is pressed or switched on.

3.3 Work window

The work window (fig. 3-1, 3) takes up the largest part of the mask. The display changes according to the operating mode and current progress.

pressed button, function active

button not pressed, function can be acti-vated

You have selected this button. As soon as you are no longer touching the screen, the desired command is executed.

You can see this button on the screen but have not activated it.

Page 32: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-3A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.1 Left and right information window

Most of the masks contain two information windows (fig. 3-1, 4) which are located above the work window.

The left-hand information window displays the following information:

• 1st line: Name of the operating mode (Vehicle Self-Diagnosis, Applications, Guided Fault Finding, Guided Functions, Administration).

• 2nd line: Name of the function activated in the respective operating mode• 3rd and 4th line: Operating instructions (e.g.: Select engine code), status (e.g.: Func-

tion not found) or detailed information on the displayed function.

Fig. 3-2 Display in the left-hand information window

NoteThe contents of the working and information windows illustrated in this operating man-ual are examples and need not necessarily be the same as the contents of your tester.

Page 33: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-4A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

In the right-hand information window, results or the previous selection are displayed. In Test Instruments operating mode, fault reports are also displayed in this window.

Fig. 3-3 Selection of a complaint report in the right-hand information window

Page 34: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-5A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.2 Dialog box

A ➚dialog box (fig. 3-1, 5) is a small mask which is displayed over the main mask. It shows additional information, operating possibilities and fault messages to be able to execute further steps in the selected program.

The following buttons may appear in the dialog boxes:

The help also appears in a dialog box. See chapter 10 for using help.

NoteAs long as a dialog box is open, the buttons of the main mask cannot be pressed. You have to press a button in the dialog box to close it first.

Table 3-1 Buttons of the dialog boxes (selection)

Button Meaning

Cancel You abort an action and return to the previous mask

Display Allows you to display image or text documents.

Exit You end an operating mode and return to the system start screen

OK You confirm the action or a dialog with "OK".

Pause Work is interrupted briefly and then continued.

Close The dialog box is closed.

Overview You are shown a selection list where you can select the desired text or action.

Interrupt Work is interrupted for an extended period of time, and data is saved.

Printer symbol: Starts a screen printout which sends what you see on screen to the selected output medium. For more details, see section 3.5.1.

Page 35: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-6A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.3 Selection bar

After selecting a line in the work window or in a dialog box, this line is highlighted by means of a black selection bar (fig. 3-1, 6). The words in the line you have selected are shown in white.

After you have made your selection, the next mask will usually appear as soon as you move your finger away from the touch screen.

If this is not the case, your tester offers you the possibility of selecting several texts. Select all the texts you want to mark. To then go to the next mask, press the Continue button (see page 3-8).

3.3.4 Scroll bar

If the complete text cannot be displayed in a dialog box or mask, a scroll bar (fig. 3-1, 7) appears on the right. It consists of a slide and two arrows. The length of the slide shows you whether it is a large or a small document. The smaller the slide the larger the text which has not yet been displayed. To read the text, place your finger on the slide and move it up or down. (VAS 5052: Alternatively, you can press and hold the upper mouse button and move the slide using the navigation button.) The desired text is displayed. You can, however, also move it line by line. If you touch or click the "Arrow down" ( ) the text moves up one line, with the "Arrow up" ( ) key it moves down one line.

Page 36: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-7A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.5 Cursor

The cursor (fig. 3-1, 8) of the tester takes on various forms depending on its present function.

Table 3-2 Forms of the cursor

Appearance Function Note

The "arrow" is the cursor form with which you select functions or buttons.

Controlled by touching the screen. On VAS 5052, it is also possible to use the mouse control.

The "hourglass" appears when the tester is processing your inputs.

No further inputs should be made when the hourglass appears. Wait until the cursor changes back to an arrow.

The ”printer” appears when you have sent a print com-mand to a connected printer by pressing the ”Print” button.

No further inputs should be made when this display appears. Wait until the cursor changes back to an arrow.

Page 37: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-8A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.6 Navigation bar

The navigation bar (fig. 3-1, 9) is at the bottom of the mask. You can call help and service functions with the buttons in this line. The work window changes every time you press a button. The navigation bar contains a maximum of eight different operating buttons as well as the indication of the date and time. The number of buttons actually available depends on the type of mask and its current state.

Fig. 3-4 Overview of buttons on the navigation bar (example)

After you have pressed the desired button, the tester will carry out the corresponding action.

If provided, the buttons appearing on the navigation bar have the following functions:

You can abort the current function or return to the previous mask with the Back button.

Using this button, you can switch from Guided Fault Finding or Guided Functions to another operating mode.

Use this button to switch directly to another operating mode.

Using this button in Guided Functions, you can go to the mask Vehicle system test.

Using this button in Guided Functions, you can start the Vehicle system test.

You call the tester help function (see chapter 10).

By pressing this button, you can view general warnings ("Caution", "Warning") and notes.

You go to the next mask with the Continue button.

Page 38: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-9A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

This button opens the "Go to destination" menu. In the menu, you will find different items depending on the current operating mode and function of the tester.

• Press "Cancel" to go to the first ➚mask of the current operating mode.

• Press "Exit" to go to the start mask.• Press "Administration" to go to a limited number of administration

functions. You can also use these functions in other active operat-ing modes, such as Test Instruments and Guided Fault Finding. Af-terwards, press the appropriate button on the navigation bar to return to the original operating mode. The following functions are available at present (depending on the tester, see chapter 9 for function descriptions):− Change dealership identifier− Contents− Print format− Display user documentation− Activate telediagnosis− Network settings− Configuration of vehicle communication

• If other applications are active in addition to the described operat-ing modes, you can switch to the applications by selecting the cor-responding name.

• In Guided Fault Finding test stepts can be selected which have al-ready been carried out. This allows you to go back in the function test in order to change entries or selections as needed (see chapter 6.3).

For the print options, see section 3.5.

Page 39: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-10A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.7 Slide controls

You can change the setting values continuously with the slide control.

Fig. 3-5 Slide control

Touch the lighter coloured control knob and pull it slowly to the right or left depending on whether you want to set the value higher or lower.

If you touch the area to the right or left of the slide control, the value is incremented or decremented.

3.3.8 Using the virtual keyboards

The tester does not have a traditional keyboard. If it is necessary to input data, a so-called ➚virtual keyboard will appear on the touch screen, allowing you to enter text by touching the "keys" on the screen. The layout of the virtual keyboard changes to suit the application case in question.

A virtual keyboard consists of an input field (which provides various keys) and a display field alongside or above it which displays the text you have input.

The tester uses several types of virtual keyboards for special tasks. Examples are shown in the following sections.

NoteYou can also enter characters using a keyboard connected to the tester. See section 3.4.1.

Page 40: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-11A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.8.1 Alphanumeric keyboard

When the alphanumeric keyboard appears on the screen you can enter letters, numbers and special characters. Your input can be viewed in the field above the keyboard.

To enter a text or string of numbers, touch or click the desired buttons in the right order.

Fig. 3-6 Alphanumeric keyboard (lowercase letters) with display field

Fig. 3-7 Alphanumeric keyboard (uppercase letters) with display field

NoteIf the text or the sequence of numbers is too long, an acoustic signal is emitted.Examples of alphanumeric keyboards are shown in fig. 3-6 and fig. 3-7. Depending on the task, different keyboards arrangements are used.

Display field forentered texts

Page 41: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-12A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Special keys

The alphanumeric keyboard has some special keys (some of which have a lighter back-ground) with the following functions.

You can use this button to delete and correct your input. If you touch or press C for "Clear" the last entered character is cleared; if you use this button several times, the text is deleted character by character in reverse as long as characters still exist.

The Q button means ➚Quit. You usually use this button to confirm and ter-minate your entry. In multi-line input possibilities, you can use Q to move to the next line. In the left hand information window you are shown how many characters and lines you can enter.

This corresponds to a keyboard shift key. When you touch or click it, the display of the keyboard changes from upper case letters with special char-acters to lower case letters with numbers and vice versa (see fig. 3-6, fig. 3-7). This button only appears in the alphanumeric keyboard.

This button is required to insert a space between words or letters.

This key moves the input position up a line.

This key moves the input position back a character.

This key moves the input position forward a character.

This key moves the input position down a line.

Page 42: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-13A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.8.2 Numeric keyboard

Enter the desired value by touching the number keys. The numbers you have input will be displayed in the field at the top.

Fig. 3-8 Numerical keyboard with display field

Special keys

The numerical keyboard includes special keys C and Q. They have the same function as those on the alphanumeric keyboard.

Page 43: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-14A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.8.3 Decimal keyboard

Enter the desired value by touching the number keys. The numbers you have input will be displayed in the field to the left.

Fig. 3-9 Decimal keyboard with display field

Special keys

The decimal keyboard includes special keys C and Q and the arrow keys. They have the same function as those on the alphanumeric keyboard. The keyboard also has the fol-lowing additional special keys:

This key inserts a positive sign.

This key inserts a negative sign.

This key inserts a decimal point.

Page 44: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-15A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.8.4 Hexadecimal keyboard

Enter the desired value by touching the characters. The numbers you have input will be displayed in the field to the left.

Fig. 3-10 Hexadecimal keyboard with display field

Special keys

The hexadecimal keyboard includes special keys C and Q and the arrow keys. They have the same function as those on the alphanumeric keyboard.

Page 45: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-16A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.3.8.5 Virtual keyboard for applications / installations

For operating applications (Elsa Win, erWin, etc.) and for installation purposes (ELSA, printer drivers, etc.), an operating bar appears at bottom right on the screen, with five rectangular operating buttons and a selection list. You can use the first four buttons to activate a virtual alphanumeric keyboard, which will appear in the corner of the screen corresponding to the symbol shown on the button you press. This virtual keyboard is lan-guage-specific and can be set via the "Keyboard assignment" function (section 9.29) in Administration.

When you press the fifth button, the virtual keyboard will disappear again and the operat-ing bar shifted to the corner last selected.

You can use the menu bar that appears in order to return to other applications that have been loaded or to the start mask via the "System Start" menu item.

Fig. 3-11 Operating bar of the virtual keyboard

Fig. 3-12 Example with GB keyboard assignment

The virtual keyboard is copyright of the manufacturer:

© 2000 MontFocus Information Systems Ltd. All rights reserved.

Page 46: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-17A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.4 USB keyboard and mouse

3.4.1 USB keyboard

If a USB keyboard is connected, you can make inputs in applications or during installa-tions. It is an alternative to the virtual keyboard in section 3.3.8.

A language-specific keyboard is provided. The keyboard can be set via the "Keyboard as-signment" function (section 9.29) in administration.

3.4.2 USB mouse

As an alternative to operating via the touch screen, a connected USB mouse can also be used with the VAS 5051B.

Page 47: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-18A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.5 Print

If you press the "Print" button on the ➚navigation bar, a sub-menu provides you with various options for the output of results via a printer/➚external storage device. Before using a printer, make that it has been set correctly (see section 9.13).• Screen: Prints the contents of the screen that is currently visible

(screen shot). This option is always possible.• Enter vehicle ID no./licence plate no.: In operating modes Vehi-

cle Self-Diagnosis, Guided Fault Finding and Guided Functions, you can enter the chassis number and licence plate number of the tested vehicle before issuing the log by using the alphanumeric keyboard that appears. In this way, the vehicle ID number and li-cence plate number will appear in the log, allowing clear identifica-tion later on. When logs are saved to removable storage device, the vehicle ID number also appears in the file name. For this rea-son, you must enter the vehicle ID number before saving. This data is deleted when you quit the operating mode.

• Safely remove hardware (not for VAS 5053) This menu item is only available if you have used a USB external storage device to output data. Make sure to select this option prior to disconnecting the external storage device from the tester, other-wise the transferred data might be lost. A dialog box informs you when you may disconnect the external storage device without any loss of data.You can find further print functions (diagnosis protocol, ...) in the appropriate sections of the corresponding operating modes.On starting a print job (screen, protocol, …) a dialog box appears so that you are able to specify the job in more detail, see section 3.5.1.

Note on protocolsIn the VAS 505x, protocols are output in XML format together with the corresponding format file "report.xsl". If data is on a external storage device and it is to be displayed on a PC, an appropriate application for reading the data is required, such as Internet Explorer 6.0. The format file is only written to the external storage device once, even if multiple protocols were output. It specifies the format of the pages displayed.

Page 48: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-19A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3.5.1 "Print/Save" dialog box

On assigning a print job, a dialog box appears. Its operating buttons depend on the cur-rent situation:

Fig. 3-13 Example of the dialog box for a print job

Use this dialog box to specify the print job in detail. You may enter multiple outputs in succession, e.g. one for a printer (paper) and one for a USB memory.

The dialog box remains open until you press the "Continue" button. The selected print job is displayed under the title bar. The option of writing to USB memory or diskette is provided only if the appropriate external storage device has been connected and recog-nised If the USB memory stick is connected later on and recognised by the system, the dialog box is updated.

If you press the printer symbol on the title bar, another dialog box appears that you can use to specify the output of the desired screen content.

Functions of the operating buttons:

• PrintPrintout via the configured printer (see section 9.13).

• Save to disketteOutput to the disc drive connected.

• Save to USB stick (USB memory)Output to the USB memory connected. You connect a USB memory later on, the cor-responding button is displayed.

• Send for online technical supportOutput to the "ProtoURL" address via LAN connection (display option, see section 9.25.4). If there is no connection, an appropriate message is displayed and the protocol is stored temporarily on the tester (also see section 6.16). You can only send the diagnostic protocol of the Guided Fault Finding/Guided Functions online.

Page 49: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operation of the masks

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.3-20A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

• Safely remove hardware (not for VAS 5053) This button appears if a USB memory is connected. Press it before you remove the USB memory (also see section 3.5).

• Save to VAS 5053 (only for VAS 5053) If no printer is connected, print jobs may be saved to the VAS 5053 and printed at a later point in time (also see section 9.14).

• Enter vehicle identification no./license plate no.If the vehicle identification no. and the license plate no. are required to output a pro-tocol (also see section 3.5), these values are requested here if they have not been en-tered yet.If the vehicle identification no. has already been entered or found automatically during the ➚vehicle system test, then you only need to enter the vehicle license number. You do not need to repeat this. After such a data request and the corresponding input, you will need to restart the printout.

• HelpHelp for the dialog.

• ContinueCloses the dialog box.

Printing the diagnosis protocol

If a diagnosis protocol is output, you are asked whether you would like a complete proto-col or a short version (see section 6.13; not for "Send for online technical support").

Printing user manuals

Printout is only possible using a printer, the "Print/Save" dialog box does not appear. However, the desired page range can be entered prior to printing.

Page 50: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Vehicle Self-Diagnosis/OBD

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.4-1A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

4 Vehicle Self-Diagnosis/OBD

NoteFor information on the use of the "Vehicle self-diagnosis" mode, see /7/.

Page 51: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-1A5E00330054/030

VAS 5051B

VAS 5051

5 Test Instruments

5.1 Overview

The Test Instruments operating mode allows you to set the testing unit with the help of parameter masks and then use the unit to perform tests. Measurement results are dis-played numerically and/or graphically on the screen.

The following functions are available in Test Instruments operating mode:

• Multimeter• ➚DSOIn addition, you can also use the buttons on the navigation bar to switch to the

• Vehicle Self-Diagnosis,• Guided Fault Finding and• Guided Functionsoperating modes. You can only do this if you began your diagnostic session in one of these operating modes.

In the Test Instruments operating mode functions you can also have selected measured values from Vehicle Self-Diagnosis displayed in parallel.

5.1.1 Printing measured values

Via the Print button and then selecting "Screen" you can output a copy of the screen to the output medium specified.

NoteThere are no special Test Instruments provided for the VAS 5052 and the VAS 5053. The measurements required for Guided Fault Finding must be obtained using external testing devices. The results of these measurements can be entered as replacement val-ues via a ➚virtual keyboard.

Caution!Use the Test Instruments only on vehicles and vehicle components.

Page 52: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-2A5E00330054/030

VAS 5051B

VAS 5051

5.2 Starting the Test Instruments

The Test Instruments are accessed from the start mask by pressing the Test Instruments button.

Fig. 5-1 Start mask, activation of Test Instruments

The "Multimeter" mask always appears after it is started.

Free use

Test Instruments can be programmed to carry out a fault search as part of a function test (see section 6.11) - for example, for checking wiring - or be used as desired. In the latter case you can select instruments directly from the start mask via the Test Instruments but-ton or via non-fixed functions on the navigation bar of the other operating modes. If the Test Instruments are currently in use in a function test they will not be available for free use.

You can change between the "Multimeter" and "DSO" masks via the "Go to" menu.

When Test Instruments is started from the start mask, the "Multimeter" mask always opens first but when switched from the ➚application operating modes it will be the mask last used which will open (multim-eter or DSO).

Page 53: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-3A5E00330054/030

VAS 5051B

VAS 5051

5.3 Multimeter

Setting the multimeter

When accessed from the start mask, the "Multimeter" mask is displayed in its basic set-ting "Voltage URD" (see fig. 5-2). When you return to the "Multimeter" mask, the setting shown will be the last one used since the operating mode was started.

Once the mask appears, the current setting is used to perform a calibration.

Fig. 5-2 "Multimeter" mask, basic setting

The "Multimeter" mask is used to operate the multimeter as a free measuring device. You can set measurement functions, perform measurements and read the test results in it.

Funktionsblock 2Funktionsblock 1

Page 54: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-4A5E00330054/030

VAS 5051B

VAS 5051

Function blocks

The buttons on screen for selecting the measurement functions of the two function blocks have differently coloured inscriptions.

The selectable measurement functions are divided into two function blocks (see fig. 5-2):

• Function block 1 (measurements via URD measuring lead, yellow inscription)− Voltage URD− Current URD (VAS 5051B) or inline current (VAS 5051)− Resistance URD− Diode test URD− Continuity test URD

• Function block 2 (measurement via current pick-ups, DSO1 measuring lead, pressure / temperature sensor, green inscription )− Voltage DSO1− Pressure T/D− Temperature T/D− Current via current pick-up

Two simultaneous measurements

You can perform one measurement from function block 1 or function block 2 or you can perform one from each of the function blocks simultaneously (for example see fig. 5-9).

Operate both measurement functions the same way as if each of them was the only measurement currently performed.

If there is a second measurement function selected in the function block which is not needed, you can switch it off by selecting it.

If there is a second measurement function selected in the function block which is not needed, you can switch it off by selecting it again.

The bar indicating the measured value and the Min/Max display under the value display are omitted when two measurements are active at the same time.

Overflow / underflow of measurement values

An overflow or underflow of measurement values for measuring the voltage, current and resistance is indicated by "+++++" or "- - - - -" in the display field and the value display of the Min/Max function.

Page 55: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-5A5E00330054/030

VAS 5051B

VAS 5051

Calibration

An automatic self-calibration feature is built in to the multimeter functions. It is performed the first time the corresponding button is activated. If you switch ➚measurement types, it will also calibrate in the new measurement type.

This calibration will also take place when you return to the Test Instruments operating mode if has been more than an hour since the last switch.

You can also perform the calibration manually if necessary (see Calibrate button, section 5.3.10).

5.3.1 Direct and Alternating Voltage Measurement

Press on the Voltage URD button to select the "Voltage measurement" measurement function.

Press the "=" button to select the "Direct voltage" measurement type. (max. 50 V).

Press the "~" button to select the "Alternating voltage" measurement type (max. 40 V).

Press the display box for the measurement range to switch from auto-matic to manual measurement range selection. You can reactivate automatic measurement selection by pressing on the display box a second time.Press this button to set the next higher measurement range when selecting measurement ranges manually.

Press this button to set the next lower measurement range when selecting measurement ranges manually.

The colours of the triangles on the measurement selection buttons indicate their status:

• Yellow triangle ⇒Measurement range changes possible• Black triangle ⇒DisabledPress the Freeze Frame button to "freeze" the measured value dis-play.

Cyclical repetition of the measurement stops and the last display is frozen.

Press the Freeze Frame button again.

Cyclical repetition of the measurement restarts and the display is updated on a continuous basis.

Page 56: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-6A5E00330054/030

VAS 5051B

VAS 5051

Fig. 5-3 "Multimeter" mask, voltage measurement

Freeze Frame remote control

Press the button on the end of the measuring lead test probe to start the Freeze Frame feature by remote control when measuring a vehi-cle.

Extreme values

While a measured value is being displayed, you can press the Mini-mum Maximum button to start the "Extreme values" function.

The "Extreme values" function calculates the current minimum and maximum values from the measured values displayed and shows them both in the measured values bar in the form of two vertical lines. These extreme value lines represent the fluctuation range of the measured values.

The values calculated for the minimum and maximum measured value are displayed below the lines.

Extreme values can only be switched on when one measured value is being displayed (not with two simultaneous measurements).

Page 57: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-7A5E00330054/030

VAS 5051B

VAS 5051

5.3.2 Direct and alternating current measurement in-line

The other elements of this mask are identical to those of the direct and alternating volt-age measurement masks (see section 5.3.1).

Fig. 5-4 "Multimeter" mask, current measurement

Press the "Current URD" or Inline current button (VAS 5051) to select the measurement function "Current measurement". You can measure currents up to 2 A (VAS 5051B) or 10 A (VAS 5051) here. The current circuit is opened and the tester is connected into it directly as an ammeter (in-line measurement).

It is only with the VAS 5051 that the red connector of theURD cable needs to be plugged into the 10 A socket of the tester.Press the display box for the measurement range to switch from auto-matic to manual measurement range selection. You can reactivate automatic measurement selection by pressing on the display box a second time.

Page 58: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-8A5E00330054/030

VAS 5051B

VAS 5051

5.3.3 Direct and Alternating Current Measurement via Current Pick-up

The other elements of this mask are identical to those of the direct and alternating volt-age measurement masks (see section 5.3.1).

Fig. 5-5 "Multimeter" mask: current measurement with the 50 A current pick-up

If the button is pressed without a current pick-up being plugged in, an error message will appear: "Current pick-up not connected". On the other hand, if one of the four current pick-ups (50 A, 100 A, 500 A or 1800 A) is plugged in, it will be detected automatically and displayed in the right-hand information window. Disconnecting the current pick-up will only be detected during measurement. When measurement is restarted after Freeze Frame, the tester detects if the current pick-up was changed and updates the right-hand information window. After a current pick-up is connected or changed, calibration will be carried out before the first measurement is made.The measurement ranges are adapted automatically to the pick-up type which was detected. Press the display box for the measurement range to switch from automatic to manual measurement range selec-tion. You can reactivate automatic measurement selection by pressing on the display box a second time.

NoteIf carrying out measurements with current pick-ups, remember to recalibrate the pick-up when measuring low currents because of possible magnetisation if you have previously used the pick-up to measure currents in a higher range. For example, this would arise when measuring the quiescent current after switching off the ignition.

Page 59: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-9A5E00330054/030

VAS 5051B

VAS 5051

5.3.4 Resistance Measurement

Fig. 5-6 "Multimeter" mask, resistance measurement

When the 0...100 Ohm measurement range is selected, the calibration for this measure-ment range is started. A dialog box prompts you to take the necessary actions.

Use of the "=" and "~" buttons is disabled.

The other elements of this mask are identical to those of the direct and alternating volt-age measurement masks (see section 5.3.1).

Press the Resistance URD button to select the "Resistance measure-ment" function.

Press the display box for the measurement range to switch from auto-matic to manual measurement range selection. You can reactivate automatic measurement selection by pressing on the display box a second time.

Page 60: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-10A5E00330054/030

VAS 5051B

VAS 5051

5.3.5 Continuity Test

Fig. 5-7 "Multimeter" mask, continuity test, connection

Freeze Frame remote control

Press the button on the end of the measuring lead test probe to start the Freeze Frame feature by remote control.

Use of the "=" and "~" buttons is disabled.

Press the Continuity test URD button to select the "Continuity test" measurement function. It indicates a connection or an open line.

Press the Freeze Frame button.

Cyclical repetition of the measurement stops and the last display is frozen.

Press the Freeze Frame button again.

Cyclical repetition of the measurement restarts and the display is updated on a continuous basis.

Page 61: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-11A5E00330054/030

VAS 5051B

VAS 5051

Display

The results of the continuity test are shown in graphical form:

When the closed switch symbol is displayed, a signal tone is also heard.

⇒ Connection (see fig. 5-7)

⇒ Interruption

Page 62: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-12A5E00330054/030

VAS 5051B

VAS 5051

5.3.6 Diode Test

Freeze Frame remote control

Press the button on the end of the measuring lead test probe to activate the Freeze Frame button by remote control.

Use of the "=" and "~" buttons is disabled.

Fig. 5-8 "Multimeter" mask, diode test, diode in forward direction

Press the Diode test URD button to select the "Diode test" measure-ment function.

Press the Freeze Frame button.

Cyclical repetition of the measurement stops and the last display is frozen.

Press the Freeze Frame button again.

Cyclical repetition of the measurement restarts and the display is updated on a continuous basis.

Page 63: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-13A5E00330054/030

VAS 5051B

VAS 5051

Display

The result of the diode test is displayed as a graphical symbol:

⇒ Diode in forward direction (see fig. 5-8)

⇒ Diode in reverse direction

⇒ Short circuit

⇒ Interruption

+ -

+ -

Page 64: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-14A5E00330054/030

VAS 5051B

VAS 5051

5.3.7 Voltage DSO1

The "Voltage DSO1 function gives you in addition to the URD functions a greater voltage measurement range up to ±400 V peak voltage (even with a.c. voltage). You can use this function in combination with the measurement functions of function block 1 (fig. 5-2) and thus make two measurements at the same time.

Fig. 5-9 "Multimeter" mask: voltage measurement via URD and DSO1

Caution! when using the DSO cablesThe DSO cables (with blue identification of the pin plug) are approved for voltage peaks up to 400 V and not designed for use in the measurement categories II, III and IV.For this reason, use the DSO cables only for measurements on the vehicle. Keep possi-ble overvoltages in mind when measuring. Measurements on the mains voltage are not permitted.

Page 65: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-15A5E00330054/030

VAS 5051B

VAS 5051

5.3.8 Pressure T/D

Bild 5-10 "Pressure T/D" mask

Connect the appropriate pressure sensor and press the button "Pres-sure T/D". The connected pressure sensor will then be detected auto-matically and ➚calibrated to atmospheric pressure. The corresponding measurement range will then be preset. The measured value display is the relative pressure. In Administration operating mode you can specify "bar" or "lb/in2" (see section 9.24).Press the Filter button to filter out higher frequency interference (more strongly damped display).

Page 66: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-16A5E00330054/030

VAS 5051B

VAS 5051

5.3.9 Temperature T/D

Bild 5-11 "Temperature T/D“" mask

Connect the temperature sensor for measuring fluids or air and press the button "Temperature T/D". The connected temperature sensor will then be detected automatically and ➚calibrated. In Administration operating mode you can specify Celsius (°C) or Fahrenheit (°F) (see section 9.24).

Page 67: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-17A5E00330054/030

VAS 5051B

VAS 5051

5.3.10 Calibrate

You should always carry out manual calibration any time you change the DSO measur-ing cable, change or use the current pick-ups at a different location, or use the tester for the first time after a long period, especially if it has been exposed to wide temperature fluctuations.

Perform the calibration manually to compensate for additional contact resistances through to the measured object in resistance tests. Short the connections to the measured object. The calibration will then cover not only the measuring lead but also the connections to the measured object.

Press the Calibrate button to perform a manual ➚calibration of the Test Instruments and the attached measuring leads. Where neces-sary, dialog boxes guide you through the further actions.

Page 68: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-18A5E00330054/030

VAS 5051B

VAS 5051

5.4 Digital Storage Oscilloscope (DSO)

Starting the DSO

Once you are in the "Multimeter" mask press the Go to button and select menu item "DSO". If you want to return to the "Multimeter" mask afterwards, in the "Go to" menu select the menu item "Multimeter".

When changing from application operating modes the mask last used in Test Instruments operating mode will appear: either the "Multimeter" or the "DSO" mask.

The first time the "DSO" mask is opened, it will display the basic settings (fig. 5-12).

From then on, each time the "DSO" mask is selected the settings used the last time the mode was started remain in force.

Fig. 5-12 "DSO" mask, basic setting

The "DSO" mask allows you to use the digital storage oscilloscope as a free measure-ment device. You can set parameters, trigger measurements and read the measurement results.

You can display up to three measurement curves on screen simultaneously. To provide clearer assignment of the functions, the button labels, the parameters and the displayed measurement signals are displayed in different colours:

• Channel A: yellow• Channel B: green• Preset measurements: blue

Time base Measurement range, coupling of channel A

Measurement range, coupling of channel B

Trigger point

Page 69: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-19A5E00330054/030

VAS 5051B

VAS 5051

You can enter the following settings in the "DSO" mask:

• Select the measurement channels using the Channel A and Channel B buttons.• Set parameters for the measurement channels (not available in Auto Setup)• Select and set parameters for the trigger channel using the Trigger mode button (not

visible when you are working in Draw mode).• Select the measuring mode using the Measuring mode button.• Setting the time base via the arrow keys

Image position and time base

If none of the buttons "Channel A", "Channel B", "Trigger mode" or "Measuring mode" has been pressed, you can select the image position and the time base.

Press this button to shift the curve grid-by-grid to the right and so to bring sections that are further left into view.

Press this button to shift the curve grid-by-grid to the left and so bring sections that are further right into view.

If the curve is shifted to the right or left, the trigger point (shown by a coloured arrow) will also be moved.Press this button to set the next higher time base.

Press this button to set the next lower time base.

NoteThe smallest time base (VAS 5051: 10 µs/Div, VAS 5051B: 1.25 µs/Div) can only be set with single-channel operation (channel A or B OFF). The button of the switched-off channel is then blanked out.

Time bases 20, 50 and 100 s/Div can only be set in draw mode.

Div. = division (raster).

Page 70: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-20A5E00330054/030

VAS 5051B

VAS 5051

5.4.1 Channel A, Channel B

In addition, a slide control appears at the right-hand margin of the display box which can be used to set the vertical shift of the displayed curve.

Beneath the slide control is the offset voltage displayed (in volts).

In a two-channel view, for example, you can position channel A in the upper portion of the display box and the signal curve of channel B at the bottom. This provides you with a clearer screen view, specially if the signal curves do not intersect.

Fig. 5-13 "DSO": two-channel display

Press the button "Channel A" or "Channel B" to display the operating functions for "Channel", "Measurement range", "Coupling", "Min / Max” and "Measurement preset" below the display field and thus be able to access them for this channel.

Page 71: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-21A5E00330054/030

VAS 5051B

VAS 5051

Instrument connection

A submenu appears with the following selection options:

CP 50A1

Current pick-up 100ACP 500ACurrent pick-up 1800APressureTemp.kV1

DSO2DSO1OFF

The line you select is highlighted.

Select the desired test connection (measuring lead) and press the Channel button again (or any other button) to accept the selection and close the menu. If you select OFF, "Channel A" is inactive.

Measurement range

You can change the measurement range by one step by pressing the "Up arrow" or Down arrow buttons. The current measurement range, e.g. "10 V/Div.", is displayed on the left of the display box (yellow - at the top - to match with channel A and green - at the bottom - to match with channel B).

Press the Channel button to enter the test connection for the pre-set channel, e.g. "Channel A".

1. CP: Current pick-up; KV: KV pick-up

NoteIf "Channel B" is already off, the OFF choice does not appear for "Channel A" and vice-versa.

Press this button to set a larger voltage range.

Press this button to set a smaller voltage range

Page 72: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-22A5E00330054/030

VAS 5051B

VAS 5051

Coupling

A submenu appears with the following selection options:

The line you select is highlighted.

Select the desired coupling and then press the Coupling button again.

• If "GND" is selected, "Channel A" is set to its reference potential (tester ground) and a flat line is displayed as the signal characteristic. In this function you can set the zero of the curve display with the slide control.

• If "DC" is selected, the direct and alternating voltage portions of the test signal are rep-resented. The pre-set DC coupling appears as a "=" symbol on the touchscreen (e.g. "2 V/Div.=", see fig. 5-12)

• If "AC" is selected, only the alternating voltage portion of the test signal is represented. The pre-set AC coupling appears as a "~" symbol on the touchscreen.

• When "LF" is selected a low-pass filter is activated which filters out higher-frequency noise.

If "OFF" is selected in the channel menu, the Coupling button is not visible.

Moving the curve vertically

If you touch the track above the slide control you can shift the slide control upwards in small steps.

If you touch the track below the slide control you can shift the slide control downwards in small steps.

Press the Coupling button to select the coupling for "Channel A".

With channel KV and temp.:

With channel DSO1, DSO2 and current pick-ups:

With pressure

GNDDC

GNDDCAC

GNDDCLF

Press on the slider and move it up or down the slide bar to shift the curve up or down.

Page 73: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-23A5E00330054/030

VAS 5051B

VAS 5051

Preset measurements

Preset measurements show sample curves for individual signals compared with the sig-nal to be measured. This presets the DSO and you do not have to make any other set-tings. If you change some settings, they will no longer match the preset measurement and the sample curve will disappear.

Select a sample curve from the list. The selected line is highlighted.

If none of the lines has been selected in the list, the prompt

First select a preset measurement

is delivered. Acknowledge it with "OK".

• In the "DSO" mask, you can use the Document button that appears to display a doc-ument relating to the selected sample curve, containing e.g. notes for adaptation, the installation position of the object measured and the operating conditions. Press the Back button to display the sample curve again.

• In the "DSO" mask the saved sample curve is displayed in blue. • The "Preset measurement" button is highlighted.• The name of the preset measurement is displayed in an information box displayed in

the upper right portion of the mask.• The measurement parameters of the selected channels are set to the values at which

the curve path of the preset measurement was saved. While a preset measurement is displayed, only the slide control, the trigger position, the display documents and the freeze frame function can be used.

You can now compare the cyclically measured curve with the fixed sample curve.

Press the "Preset measurement" button again to end the "Preset measurement" func-tion. The hidden buttons reappear.

If you press the one of the buttons "Channel A", "Channel B", "Trigger Mode" or "Measur-ing Mode" during the "Preset measurements" function, it will be exited automatically and the preset curve will disappear from the screen.

When you press the Preset measurement button the " Preset meas-urements" mask appears displaying a list of available sample curves.

Press the Display button in the "Preset measurements" mask to dis-play the selected sample curve.

Page 74: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-24A5E00330054/030

VAS 5051B

VAS 5051

Min/Max values

This function delivers the extreme values (minimum and maximum) of all curve values of the selected channel which occurred since the start of measurement. Display of the val-ues cannot be moved to another position on the screen.

Extreme values are registered by an overscanning even between the actual scanning times. The curve displayed does not appear as smooth as in the normal plot - this is due to the alternating display of minimum and maximum values.

With the two smallest time bases (ms/Div) and in draw mode, extreme values cannot be displayed.

You can switch display of extreme values back off by pressing the Min/Max button a sec-ond time. Switching the min / max function off and on resets to zero the display of the ex-treme values during scanning.

Press the Min/Max button to display at the lower edge of the oscillo-gram the extreme values of the current channel in numerical form and in the same colour as the corresponding channel (see fig. 5-13).

Page 75: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-25A5E00330054/030

VAS 5051B

VAS 5051

5.4.2 Measuring mode

When it is pressed, the buttons "Auto set-up", "Auto level", "Auto", "Normal", Single" and "Draw mode" appear below the display field.

Fig. 5-14 "DSO" mask: auto level mode, measuring mode

Measured value acquisition is parametrized with the Measuring mode button.

In auto setup mode the amplitudes of channel A and B, the time base and the trigger threshold are set automatically.

Auto setup is performed only once each time it is called. Measuring mode then switches automatically to auto level mode.In auto level mode the set trigger threshold (percentage threshold in the range ±100 % of the signal amplitude) is tracked automatically so that a triggered image is always visible independent of the signal amplitude.In auto mode measured value acquisition starts automatically in free-running operation when a valid trigger event occurs (according to the pre-set trigger level) or when a wait time dependent on the selected time base has elapsed (no freeze frame).

Page 76: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-26A5E00330054/030

VAS 5051B

VAS 5051

In normal mode, cyclical measured value acquisition takes place only when a valid trigger event occurs. If the trigger is missing, a prompt appears in the display box at the right.In single mode, a measurement is taken only once after a valid trigger event.

NoteThe Auto Setup and Auto Level functions can only be used if triggered internally (that is, the trigger signal must be selected as a measure channel) or if the trigger pick-up is used.Auto level and auto setup can only function smoothly with periodic signals with low interference.

In draw mode, measured values are acquired without triggering and the curve is plotted continually from left to right. Draw mode is used for displaying low-frequency signals. Long-term measurement is also possible in draw mode. Extreme values cannot be displayed.

NoteThe time base in draw mode can be set from 0.2 to 100 s/Div.

Page 77: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-27A5E00330054/030

VAS 5051B

VAS 5051

5.4.3 Trigger Mode

Here you can set the trigger time point from which the signal to be measured is to be recorded.

A slider also appears at the right edge of the display box which you can use to set the ➚trigger level.

Fig. 5-15 "DSO" mask, trigger mode

The vertical position of the trigger point in the display field (shown by an arrow) indicates the trigger position. Below the slide control you will see the corresponding trigger voltage or (in the case of "Auto level" measuring mode) the trigger value in %.

Provided the trigger position is within the valid measurement range, the trigger point lights up in the colour of the channel selected (blue in the case of external triggering - does not take place via the measurement lines for channel A or channel B). If not, it appears in red. The upward- or downward-pointing direction of the arrow shows whether triggering will happen with a rising (positive) or falling (negative) edge.

Press the "Trigger mode" button to display the operating functions for "channel", "coupling", "edge" and "horizontal movement" under the display field and thus be able to set it.

Page 78: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-28A5E00330054/030

VAS 5051B

VAS 5051

A submenu appears with the following selection options:

CP 50 A1

CP 100 ACP 500 ACP 1800 APressureTemp.Pick-up1

kV1

DSO2DSO1The line you select is highlighted.

Select the desired measurement connection for triggering and press the Channel button again.

According to the selection "channel A", "channel B" and the "coupling" set there, a sub-menu appears with at least part of the following selection options:

HFLFDCAC

The selected line is highlighted.

Select the desired coupling and then press the Coupling button again.

• Selecting "HF" (high-pass filter) filters out the low-frequency components of the trigger signal.

• Selecting "LF" (low-pass filter) filters out the high-frequency components of the trigger signal.

• If "DC" is selected, the trigger signal will be DC-coupled (DC and AC components in-cluded).

• If "AC" is selected, the trigger signal will be AC-coupled (DC components filtered out). Selecting "AC" is not possible in draw mode.

Press the Channel button to select the measurement connection for the trigger signal.

1. CP: Current pick-up; Pick-up: trigger pick-up; KV: KV pick-up

Press the Coupling button to select the "Coupling" for "Trigger mode".

Page 79: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-29A5E00330054/030

VAS 5051B

VAS 5051

A submenu appears with the following selection options:

neg.pos.

The selected line is highlighted.

Select the desired edge and then press the Edge button again.

• If "neg." is selected, the falling edge of the trigger or test signal is used.• If "pos." is selected, the rising edge of the trigger or test signal is used.

Touch the track above the slide control to move it step by step upwards and thus set the trigger level to higher voltage values.

Touch the track below the slide control to move it step by step downwards and thus set the trigger level to lower voltage values.

NoteIf the "Pick-up" trigger signal is selected, the Coupling button is not visible."AC" coupling is not displayed when there is "DC" coupling shown for the selected mea-surement channel, and vice versa.

Press the Edge button to select the edge of the trigger or test signal you want to trigger.

NoteIf the "Pick-up" trigger signal is selected, the Edge button is not visible.

Press this button to move the trigger grid by grid to the left and thus bring sections further to the right into view.

Press this button to move the trigger grid by grid to the right and thus bring sections further to the left into view.

Press the slider and move it up and down the slide bar to change the trigger level.

NoteThe slider is not visible when the "Pick-up" trigger signal is selected.

Page 80: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-30A5E00330054/030

VAS 5051B

VAS 5051

5.4.4 Bandwidth limiting (VAS 5051B only)

5.4.5 Freeze Frame

The "Cursor 1" and "Cursor 2" buttons also appear (see section 5.4.5.1).

Press the Freeze Frame button again.

The cyclic repetition of the measurement is restarted.

Freeze Frame remote control

Press the button on the end of the measuring lead test probe to start the Freeze Frame feature by remote control.

Parameters changed

If you change parameters while using the Freeze Frame function, the curve on display is not affected. The message "Parameter changed" does, however, appear in the informa-tion box at the right because the curve and the set parameters no longer match.

By default, the "Bandwidth limiting" button is enabled automatically up to 0.01 ms/div. A low-pass filter with a 75-kHz cut-off frequency is acti-vated in all measurement channels. This blocks out high-frequency components and the display is roughly the same as with the VAS 5051. For high-frequency signals such as CAN bus signals, bandwidth limiting can be disabled manually, as required.

Press the Freeze Frame button.

Cyclical repetition of the test is paused and the last curve is frozen.

Page 81: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-31A5E00330054/030

VAS 5051B

VAS 5051

5.4.5.1 Freeze frame with one measurement cursor displayed

Fig. 5-16 "DSO" mask, freeze frame with a cursor

The "Amplitude Channel A" display box (➚amplitude) shows the voltage value at the point in the curve for channel A where the cursor is positioned.

The "Amplitude Channel B" display box shows the voltage value at the point in the curve for channel B where the cursor is positioned.

The "Time value" display box shows the time value at the point in the curve where the cursor is positioned, referred to the trigger point.

Touch the curve to move the cursor to this point (rough control).

Press the "Cursor 1" or "Cursor 2" button to determine voltage values at specific time points on the curve.

The following mask appears when you press the button:

Press this button to move the cursor to the left (fine control).

Press this button to move the cursor to the right (fine control).

Page 82: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-32A5E00330054/030

VAS 5051B

VAS 5051

5.4.5.2 Freeze frame with measurement cursor 1 and measurement cursor 2 displayed

Press the "Cursor 1" and "Cursor 2" buttons to determine voltage and time difference val-ues between particular points on the curve.

When the "Cursor 2" button is pressed, cursor 1 cannot be moved.

Touch the curve to move the cursor (rough control).

Press the "Cursor 1" button and place the cursor, as described in section 5.4.5.1, at the point on the curve for which you want to deter-mine the voltage and/or time differences when compared with the cur-sor 2 position (reference point).Press the "Cursor 2" button and place the cursor at the point on the curve for which you want to determine the voltage differences to the position of cursor 1.

Press this button to move the cursor to the left (fine control).

Press this button to move the cursor to the right (fine control).

Page 83: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-33A5E00330054/030

VAS 5051B

VAS 5051

Once both cursors have been activated, the following mask is displayed:

Fig. 5-17 "DSO" mask, freeze frame with Cursor 1 and Cursor 2

The "Amplitude difference A" display box shows the voltage difference between the two points on the curve for channel A where the cursors are located.

The "Amplitude difference B" display box shows the voltage difference between the two points on the curve for channel B where the cursors are located.

The "Time difference" field shows the time difference value between the points where the cursors are located.

Page 84: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-34A5E00330054/030

VAS 5051B

VAS 5051

5.4.6 Long-term measurement in draw mode

Long-term measurement allows a time interval to be set for the measurement process in "Draw" measurement mode. After recording, the signal curves are compressed to the width of the window and output accordingly. A zoom function allows you to look more closely at selectable parts of the curves.

When the "Draw mode" button is pressed, the "Long-term measurement" button appears (see fig. 5-18).

Fig. 5-18 "DSO" mask with button for setting long-term measurement

NoteSince all measured values are compressed to the width of the window, values from self-diagnosis cannot be displayed or recorded during long-term measurement.

Pressing the "Long-term measurement" button takes you to the mask for setting long-term measurement (see fig. 5-19). The "Freeze frame" function is switched on for this purpose. The "Long-term measurement" button remains hidden during the measure-ment. Touch one of the buttons for hours and minutes to select them for setting with the arrow keys. The previously set time is retained for a repetition of the long-term measurement.

Page 85: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-35A5E00330054/030

VAS 5051B

VAS 5051

The maximum duration of a long-term measurement is limited by the sampling rate and the number of channels being recorded since as the sampling rate increases, the quan-tity of data also rises. The maximum recording period at a sampling rate of 5 Hz is 48 h.

Fig. 5-19 "DSO" mask with elements for setting long-term measurement

After pressing the "Long-term measurement" button you next set the time for the meas-urement interval. To start the measurement process, deactivate the Freeze Frame but-ton.

The right-hand button decrements the hour or minute by one unit.

The left-hand button increments the hour or minute by one unit.

After pressing the "Long-term measurement" button and setting the time for the measurement interval, start the measuring process by dis-abling the "Freeze frame" button.

NoteDuring the long-term measurement, no USB cables or USB peripheral devices, such as external storage devices, keyboards etc. may be removed or connected. That could result in the loss of data.

Page 86: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-36A5E00330054/030

VAS 5051B

VAS 5051

While recording is in progress, the right-hand information window shows the reception time. During this period you cannot change the parametrization of long-term measure-ment but you can abort early by pressing the Freeze Frame button again. The measure-ment result is then displayed as if the time up to that point were actually the time which had been set.

Once the time period has finished, long-term measurement ends. The Freeze Frame function switches itself on automatically and all of the data recorded is compressed to the window width and displayed (see fig. 5-20). This presentation is formatted in such a way that the extreme values of the compressed data are displayed.

At the end of long-term measurement you can evaluate the signal curve with the aid of cursors 1 and 2 (see section 5.4.5.2).

Bild 5-20 "DSO" mask with normal display

You can however zoom in on any section you wish.

Select the section you want to magnify either by tapping at a point on the measurement curve or by selecting a section, dragging it over the screen and releasing it. In the mean-time the start and end of the zoom section are marked by cursor 1 and cursor 2.

The Zoom button is only displayed when no cursor function is active.

Press the Zoom button to zoom in on a section of the recorded data. Pressing the Zoom button again switches the zoom function back off.

Page 87: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-37A5E00330054/030

VAS 5051B

VAS 5051

The selected range is now expanded to fill the width of the display (see fig. 5-21). You can keep magnifying a section until the data displayed cannot be expanded any more.

Briefly tapping on a point causes the data in its vicinity to be expanded to the maximum immediately.

Fig. 5-21 "DSO" mask with zoomed display

Even in the zoom display you can use the cursor functions in the usual way.

Press this button to move the displayed area grid by grid to the left until the lower storage limit is reached.

Press this button to move the displayed area grid by grid to the right until the upper storage limit is reached.

Page 88: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-38A5E00330054/030

VAS 5051B

VAS 5051

5.4.7 Tips and Information

Auto setup - Your most valuable button

The DSO is equipped with an auto setup mode which automatically calculates and makes all DSO settings in response to periodic input signals. If channels A and B and the trigger are correctly selected, after a short time you will get an optimally triggered display which continues in "Auto level" mode.

If no curve is displayed, check why in the following order:

1. Are the DSO leads correctly connected to the tester?For most applications connect the DSO leads as follows:DSO1 lead to input DSO1, DSO2 lead to input DSO2

2. Is the correct channel input selected?For most applications set the DSO for "Channel A" or "Channel B" as follows:Channel A to DSO1 (default), channel B to DSO2 (default)

3. Is the correct trigger channel selected? For most applications set the channel in trigger mode as follows:Channel to DSO1 (default)

4. Repeat auto setup.If possible, auto setup mode with switch to auto level mode is always preferable. Auto setup can also be repeated at any time.

No trigger

In normal and single mode: Triggering will work best when you bring the trigger point onto a clear amplitude value. Use the trigger’s fine adjuster. If the trigger is outside the amplitude, the message "No trigger" appears. Depending on the preconditions, no signal characteristic at all or a frozen signal characteristic (no measurement) will then be dis-played.

Now return the trigger manually to the amplitude range until the message disappears.

Page 89: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-39A5E00330054/030

VAS 5051B

VAS 5051

Auto level

In auto level mode you can trigger signals independently of their amplitude and zero position, because then the triggering is based on a percentage amplitude value.

After the auto setup is completed the mode changes automatically to auto level and the triggering is set to 0 % of the amplitude value. In trigger mode you can use the slide con-trol to set any unambiguous trigger value between ± 100%; otherwise the DSO triggers in the middle of the measured signal.

Auto

If you have no information about the signal, use auto mode. In this case, the curve is also output even if the trigger is outside the amplitude (untriggered display).

Afterwards move the trigger manually to a value within the amplitude range for a freeze image.

Normal

Use normal mode if you are familiar with operation of the DSO. You will only get an image when the trigger is within the amplitude range of the measured signal. Make sure there is a valid trigger event.

Single

In single mode you can record a one-off event. The signal is measured and displayed immediately as a freeze frame. Make sure there is a valid trigger event.

Page 90: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-40A5E00330054/030

VAS 5051B

VAS 5051

5.5 Parallel mode with Test Instruments and Vehicle Self-Diagnosis

5.5.1 Overview

As an option you can run Vehicle Self-Diagnosis and Test Instruments in parallel. Here, in the "Multimeter" and "DSO" masks, in addition to the measured values you can also display the following values which Vehicle Self-Diagnosis reads off cyclically in the back-ground (see fig. 5-22):

• Measurement and status values of the "Final control diagnosis" diagnostic function• Measurement and status values of the "Read measured values block" diagnostic

function• Measurement and status values of the "Basic settings" diagnostic function• Measurement and status values of the OBD functions• Measurement and status values of the LT2 functions• Measurement and status values of the LT3 functionsIn each case up to 4 self-diagnosis values can be displayed. If more values are read out, the first four will be displayed.

Fig. 5-22 "Multimeter" mask displaying measured values from the Vehicle Self-Diagnosis

Page 91: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-41A5E00330054/030

VAS 5051B

VAS 5051

After you return to a vehicle self-diagnosis mask, a triggerable configured DSO measure-ment is retained - for example, a single-shot measurement for a valve control pulse. In Vehicle Self-Diagnosis you can then perform operations in the usual manner - in other words, you could press the Continue button, for example, to continue with a final control diagnosis. When you return to the "DSO" mask afterwards, it will now also show the curve which was measured in the background.

5.5.2 Operation

Parallel operation of vehicle self-diagnosis and test instruments is be possible if you switched from "Vehicle self-diagnosis" operating mode to "Test instruments". If Test Instruments operating mode is called directly from the start mask, parallel operation will not be available.

With OBD and LT values you can, if applicable, display the corresponding designator by briefly tapping on the value from vehicle self-diagnosis (see fig. 5-23). Tapping once more on the screen outside the measurement value bar causes the designator to disap-pear again.

While parallel operation is active, you can use the Test Instruments and Vehicle Self-Diagnosis buttons to switch back and forth between the operating modes.

NoteSince the two operating modes do not function synchronously, in the display of the measured values phase shifts will occur, these being caused by the time behaviour of the control units and of the tester operating system. With fast dynamic events the val-ues from Vehicle Self-Diagnosis serve only as additional information and should not be linked with the measured values from Test Instruments in a causal temporal relation-ship.

In the "Multimeter" or the "DSO" mask press the "Meas. values Self-Diagnosis" button. It will not be displayed then in the Test Instruments masks unless you switched over to it from Vehicle Self-Diagnosis.

Page 92: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-42A5E00330054/030

VAS 5051B

VAS 5051

You can only end parallel operation and self-diagnosis measurements in "Vehicle self-di-agnosis" operating mode.

Press the "Freeze Frame" button to freeze the measured value dis-play. This pauses the cyclical repetition of the measurement and the last display remains on screen without changing.Press the Freeze Frame button again. The cyclic repetition of the measurement is restarted.The cyclic display of the measured values from the vehicle self-diag-nosis is not affected by the "Freeze frame" function.

In the "Multimeter" or the "DSO" mask press the "Meas. values Self-Diagnosis" button again to hide display of parallel mode. Self-diagno-sis measurements here continue in the background.

Page 93: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-43A5E00330054/030

VAS 5051B

VAS 5051

5.5.3 Values of "Final control diagnosis" diagnostic function

To display values of the "Final control diagnosis" diagnostic function, proceed as follows:

1. Switch from Vehicle Self-Diagnosis operating mode to Test Instruments operating mode, "Multimeter" or "DSO" mask.

2. Press the "Meas. values Self-Diagnosis" button.3. Switch over to Vehicle Self-Diagnosis operating mode.4. Start final control diagnosis.5. Switch back over to the "Multimeter" or the "DSO" mask. Here the value registered by

final control diagnosis will be displayed (see fig. 5-23).

Fig. 5-23 "Multimeter" mask displaying values from the final control diagnosis

While the display is active you can change back to Vehicle Self-Diagnosis and press the Continue button in order to access the next final control diagnosis.

Trigger conditions cannot be set within multimeter mode. Display is solely the values of Vehicle Self-Diagnosis in parallel with the measured values of the multimeter.

NoteDesignators of values are currently available only for OBD values and LT2 control units.

Page 94: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Test Instruments

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.5-44A5E00330054/030

VAS 5051B

VAS 5051

5.5.4 Values of the "Read measured values block" and "Basic settings" diag-nostic functions

To display values of the "Read measured values block" and "Basic settings" diagnostic functions, proceed as follows:

1. In Vehicle Self-Diagnosis select a block of measured values (see /7/).2. Switch to the "Multimeter" or the "DSO" mask.3. Press the "Meas. values Self-Diagnosis" button. Up to four values registered cyclically

in the background will be displayed (see fig. 5-22).

5.5.5 Values of "OBD" operating mode

Basically the same rules apply as with displaying values of the "Read measured values block" and "Basic settings" diagnostic functions: A maximum of four values is displayed. In addition the following restrictions apply:

• When more than four OBD values are measured - six PIDs, for example - only the first four values are displayed.

• Only numerical values are displayed.• Only actual values are displayed - that is, no setpoint values are shown (such as min

/ max values).

Fig. 5-24 "Multimeter" mask displaying OBD values

Page 95: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-1A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6 Guided Fault Finding

6.1 Overview

This operating mode is not available to the VAS 5053.

The ➚"Guided Fault Finding" operating mode "guides" you from the vehicle identification and detecting a vehicle malfunction (➚fault symptoms) to locating the cause of the fault and finally to eliminating that cause. All the vehicle information (fittings, symptoms, functions and components, documents and function tests) is automatically compiled and made available for this purpose.

All functions from the operating modes "Vehicle self-diagnosis" and "Test instruments" (only VAS 5051 / VAS 5051B) are available in the "Guided Fault Finding" application and are integrated in function tests there.

The fault symptoms are made available to the Guided Fault Finding application from three different sources:

• Fault memory contents (from vehicle systems)• Complaint reports (from user input)• ➚Experience rules (field findings stored in the system)In addition, you have the option of selecting functions or components yourself and incorporating them into the ➚test plan or displaying the documents assigned to them.

The sequence of operations for Guided Fault Finding can be seen in fig. 6-1; this diagram will also direct you to the sections in which the individual areas are explained in detail.

NoteYou can only use the Guided Fault Finding operating mode if at least one brand CD has been installed on the VAS 505x. For information on installing brand CDs, see section 2.5 and section 9.4.3.

NoteGuided Fault Finding only provides limited testing possibilities for old vehicles: the vehi-cle system test for reading the fault memory and also a few customer service functions via the function / component selection. Special fault-finding programs are not provided here.

Page 96: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-2A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

(1) Start mask

Guided Fault Finding is initiated from the start mask (for further information, see section 6.2).

(2) Vehicle identification, ➚gateway installation list, ➚basic features

Guided Fault Finding begins with vehicle identification. This can occur either automati-cally, by means of a gateway installation list, or manually, via input of the basic features, or via a mixture of the two (automatic and manual). In some cases, questions can be pre-sented e.g. concerning the national variants. The diagnostic cable must be connected and the ignition must be switched on for automatic and mixed vehicle identification (for further information, see section 6.4).

(3) Vehicle identification, vehicle system test, read fault memory

The vehicle-system test follows once the basic features have been determined and / or input. All the electronic vehicle systems that can be present, given the basic features of the vehicle specified, will be represented in a mask. Vehicle communication will be used to check which vehicle systems and variants are built into the connected vehicle. In addi-tion, their fault memories are be read and their contents displayed once the ➚start mod-ule has finished (for more information, see section 6.6).

(4) Execute start module

Depending on the nature of the diagnostic data, a ➚start module may be run after the vehicle system test. One or more function tests can be started in it, for example, to read out the vehicle identification number (VIN) (for more information, see section 6.6.3).

(5) Fault memory contents

Here the fault memory contents read from the vehicle systems and the associated texts sorted by default by control unit number and fault code are displayed in a mask. If the corresponding ambient conditions are present, they can also be sorted by these (for more information, see section 6.7).

From this mask on you can use the Go to button to switch to function / component selec-tion, where you can select a component yourself, and either enter it in the test plan or display its associated documents.

Page 97: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-3A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

(6) Fault memory entries available?

If there are fault memory entries available, the run sequence proceeds to the test plan; if this is not the case, it goes to the "Complaint Report" mask.

(7) Test plan

In the test plan, an automatic test plan is compiled from the fault symptoms that were available and that were entered. The component with the highest degree of suspicion is placed at the very top and is preselected for processing. The results of each function test lead to a re-evaluation of the test plan with a suggestion for the next processing sequence, so the order of function tests suggested can change or others can be added (for further information, see section 6.10).

(8) Function test

A ➚function test starts a function test (test program) that consists of a sequence of ➚test steps, with which it can localise a fault down to the level of an individual component, lead and plug or control unit. The function test's operation is dialog-controlled and uses the full Vehicle Self-Diagnosis functionality e.g. "Read Data Block", "Adaption" etc. With VAS 5051, the internal Test Instruments (multimeter, oscilloscope) are utilised for the function test, e.g. for lead and signal tests.

With VAS 5052, these measurements must be made using external testing devices. The function test dialog boxes allow replacement values to be entered, i.e. you use an external device to take measurements at the measuring points specified and then enter the measured value via a virtual keyboard (for further information, see section 6.11).

(9) Leaving the Guided Fault Finding application

You leave Guided Fault Finding via the "Go to" function. You can "Interrupt" the diagnosis session, "Cancel" it or "Exit" it.

Interrupt

This function permits you to interrupt the diagnosis session briefly (to pause it) or to save the diagnostic session in order to resume it later (for further information, see section 6.12.1).

Page 98: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-4A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Exit

At exit all vehicle systems are checked once again and with faults set the fault memory is cleared and then read again. If there are still faults present, Guided Fault Finding can be continued or be definitively terminated (for further information, see section 6.12.3).

With OBD vehicles when the readiness code is deleted or faulty it can still be generated again via an inquiry.

Cancel

Cancel is like Exit, except here the program goes back to the first Guided Fault Finding mask instead of the start mask.

(10) Executing end module

Depending on the nature of the diagnostic data, an end module may be started before leaving the Guided Fault Finding application. One or more function tests can be started in the stop module, which can be used e.g. for feedback to the vehicle manufacturer (for more information, see section 6.15).

(11) Complaints

If no fault is recognised in the vehicle system test, the Guided Fault Finding application automatically takes you to the "Complaint report" mask. Information about "Technical problem solutions" is available here. In addition, you can enter the complaint lodged by the customer or your own observations. Several symptoms can be registered, in order to establish the ➚fault characteristics as precisely as possible. The tester evaluates the symptoms using the expert knowledge contained on its hard drive (for further informa-tion, see section 6.8).

You can also reach the dialog for entering complaints using the Go to button from the "Test plan" mask (seesection 6.10). This enables you to give the tester additional infor-mation for its fault memory entries.

(12) Function/Component selection

Here, you can directly enter functions or components that, according to your experience, could possibly be the sources of the fault(s). The functions and/or components selected are entered in the test plan (➚User Test Plan) (for further information, see section 6.9). However, you can also select Display Documents via the Go to button and display the documents belonging to the selected component.

Page 99: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-5A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Fig. 6-1 Basic run sequence of Guided Fault Finding

Vehicle system test

Test Plan

Display fault memorycontents

Installation list,basic features

Function test

Are fault memoryentries available? Complaints

yes

Execute end Module(if available)

Function / ComponentSelection

Vehicleidentification

no

Execute start module(if available)

EndGuided Fault

Finding

Start mask

2

3

4

5

6

7 8

9

10

1112

1

section 6.4

section 6.6

section 6.9 section 6.8

section 6.10

section 6.11 section 6.12.3

section 6.7

section 6.6.3

section 6.15

Page 100: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-6A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Problem log

If you have problems during a function test, you can use the "Go to" function to save the previous process to a external storage device (for more information, see section 6.3) and pass the information on.

On-line feedback log

An ➚on-line feedback log is available at the end of the diagnosis session for sending feedback to the manufacturer (for further information, see section 6.16).

Operating mode button in the navigation bar

In Guided Fault Finding, you can use the Operating mode button to switch over to the operating modes Test Instruments (VAS 5051 only), Vehicle Self-Diagnosis or Guided Functions, to e.g. carry out a measurement there or a diagnosis function outside of Guided Fault Finding. Functions from Test Instruments or Vehicle Self-Diagnosis that are presently being used by Guided Fault Finding will disappear.

Switching back to the Guided Fault Finding operating mode always takes you back to the mask from which the switchover occurred. Processing of the operating mode can con-tinue unrestricted from that point.

Go to button on the navigation bar

You can use the "Go to" function to interrupt Guided Fault Finding, cancel it, exit it, read ➚ECU identification data, generate the problem log, or switch over to other Guided Fault Finding functions that have already been run (see section 3.3.6 and section 6.3).

Print button in the navigation bar

The following options are also displayed for selection if you have reached the "Test plan" mask:

• Diagnostic log: From the test plan, you can print out a log of all previously run func-tion tests or save it to the removable storage device.

• Function test log: From the test plan, you can print out a log of the last function test run or save it to the removable storage device.

See also section 3.5, section 6.13 and section 6.14.

Page 101: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-7A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.2 Start Guided Fault Finding

Guided Fault Finding is launched from the start mask. It begins with selection of the brand and the subsequent vehicle identification.

Fig. 6-2 Start of Guided Fault Finding

Page 102: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-8A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.3 "Go to" destination menu

In the Go to Destination menu ("Go to" button), you are given various options for leaving the Guided Fault Finding application (see section 6.12.) and some administration func-tions (see section 3.3.6).

Using the "Go to" menu, you can however access other functions and masks of the Guided Fault Finding application. It contains the titles of the Guided Fault Finding masks which have already been run, for example, "Vehicle system test", "Fault memory con-tents", "Test plan," and the titles of the test steps already processed in the function test. User-guided masks such as "Complaint report", "Function / component selection", and "Documents" are also contained in the list (for an example, see fig. 6-34). You can return to any of these masks via the "Go to" menu in order to resume Guided Fault Finding at that point.

Under "ECU identification data" you can obtain information about all vehicle systems which have been read as part of vehicle identification.

Example:

019 - Databus OBD Interface4E0910468B 4E0907468Gateway H10 0080Long codingDealership number 12345

01 - Engine electronics4F0910560C 8E0907560 *E5F8C60 H10 ---XE09Coding 5711Dealership number 12345

"Documents" displays only the documents of the last component selected in Function/Component Selection.

If you use a Go to destination (or, where applicable, the "Back" button) to return to a pre-vious test step, you can browse through and have another look at the course of the test up to that point e.g. using the "Continue" button. Existing results and decisions made in test dialogs will be displayed to you. As you go through, you can also repeat and correct measurements and test dialogs. However, from this point on, you must run through the rest of function test as new, since new results and decisions could produce a different program run sequence.

Page 103: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-9A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

The "Export problem log" item is another function in the "Go to" menu. If a fault occurs during a function test, you can use this function to save to a removable storage device the run sequence up to that point. Before you save the log you will need to provide via the virtual keyboard a job code for the diagnostic session under which the job can later be found and reloaded. The saved run sequence will show all masks run through in the course of the diagnostic session, and provides additional feedback for the manufacturer. The Guided Fault Finding Light program (not included in the current package) can be used by the manufacturer to import and examine the data.

A removable storage device can hold several diagnosis sessions and screenshots.

You can switch over to other tester operating modes such as "Vehicle Self-diagnosis" and "Guided Functions" via the "Operating mode" button on the navigation bar.

6.4 Vehicle identification

The vehicle identification is for the clear identification of the vehicle by means of basic features (type, model year, variant, engine code) and its control unit equipment as well as other data, such as e.g. the vehicle identification number (VIN).

The basic features can be determined manually via a selection list provided on the tester or automatically. Vehicles with gateway and CAN diagnostics support the identification process, since the gateway provides an installation and status list containing important data for the vehicle identification. In this respect, an identification process for a vehicle with gateway and CAN diagnostics differs from that for a vehicle without gateway and CAN diagnostics.

The following description therefore distinguishes between:

• Vehicle without CAN diagnostics• Vehicle with CAN diagnostics

Page 104: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-10A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.4.1 Vehicle without CAN diagnostics

After selecting the brand, the basic features are selected and entered manually. The sequence is as follows:

1. Type,2. Model year,3. Variant,4. Engine code.A request to confirm the vehicle identification follows. If there is no connection yet be-tween tester and vehicle, the next picture is displayed and the request to establish the connection (section 6.5). Then, the vehicle system test is performed (section 6.6).

6.4.2 Vehicle with gateway and CAN diagnostics

Provided that communication with the gateway is possible (also see section 6.4.2.2), a message appears:

Communication setup with vehicle systems

The tester reads the installation list and its status information from the gateway control unit and saves it for further evaluation. The installation list indicates e.g. whether a con-trol unit is registered in the gateway (coded) and/or its fault memory is set.

If a non-coded control unit is registered, It can be coded without delay (see section 6.4.2.1). The fault status is used during the vehicle system test, thus allowing the interrogation of the fault memory to be restricted to the indexed control units.

Depending on the brand and the type, an identification test can already take place before selecting the first basic feature (type) that builds on the gateway data already read and further data can be identified, such as e.g. basic features, national variants (about ques-tions) and the vehicle identification number (VIN). In the best case, all basic features can be determined, so that the identification process takes place fully automatically.

If the automatic identification of the basic features is not given, the tester offers the man-ual input of the the non-identified values:

• Type,• Model year,• Variant and• Engine code.The confirmation of the vehicle identification follows the specification of the basic features (see section 6.5).

Page 105: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-11A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.4.2.1 Gateway not registered

If individual control units are detected as being "not coded" (not registered) when the installation list is evaluated, you will have to recode these control units. Guided Fault Finding automatically activates the "Reading / writing long coding" self-diagnosis function for this purpose.

Fig. 6-3 "Select vehicle systems for coding " mask

Proceed as follows to code:

1. Select all entries marked as "not coded". They change to the "coded" status (registered).

2. Press the Continue button to start coding. Coding is executed in the gateway.The installation list of the gateway is read again and checked for control units that are not coded.

If the coding is once again incorrect, a fault report to that effect will appear. After this you can repeat the coding or press "Continue" to begin manual vehicle identification. You can repeat coding or press the "Continue" button to begin vehicle identification. In this case, the subsequent vehicle system test generates an malfunction message since the gateway was not coded correctly or could not be read. For this purpose,a special communication test, adapted to the gateway, can be presented.

Page 106: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-12A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.4.2.2 No communication with gateway

If the tester was unable to set up communication with a gateway control unit, it will present you with the manual vehicle identification option. Here, select the vehicle's basic features one after the other from selection lists that you are shown. The previously selected basic features will appear in the right-hand information window of the following masks, for verification of the selection made.

After selecting the fourth basic feature, the "Check vehicle identification" mask appears. At any time, you can switch back to the previous screen using the "Back" button to make a different selection there. The next mask shows the next picture (see section 6.5). If you now press the "Continue" button, the tester attempts to establish communication with the gateway again. If this does not work again, the following note appears:

Fig. 6-4 Note: "No CAN communication possible"

Page 107: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-13A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.5 Confirming vehicle identification, diagnostic connection

The following mask concludes vehicle identification. The basic features specified are shown in the right-hand information window. Check carefully whether the vehicle to be diagnosed matches the entries exactly. With manual vehicle identification, you can press the "Back" button to switch back to the previous masks to make changes there if neces-sary.

Fig. 6-5 "Confirm vehicle identification" mask

When you press the "Continue" button, the diagnostic data for the specified vehicle is loaded from the hard drive into the working memory and communication with the vehicle is established.

If you have not yet connected the diagnostic cable with the vehicle, you will be prompted to connect it after confirmation of the vehicle identification. To do so you will be shown a document displaying the fitting location of the diagnostic connection.

Page 108: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-14A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Fig. 6-6 "Connect VAS 505x to vehicle" mask

If you press the "Continue" button, the tester attempts to establish communication with the vehicle again. You can repeat the communication setup any number of times or can-cel it if you are unsuccessful continuously. In either case, the tester switches to the vehi-cle system test.

If communication could not be established during CAN diagnosis, the tester sets a special communication test in the test plan without previous vehicle system test (see section 6.4.2.2).

Page 109: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-15A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.6 Vehicle system test

The vehicle system test checks whether electronic vehicle systems are present in vehi-cle and whether they have any saved fault entries. If automatic vehicle identification was possible via a gateway control unit, the list of possibly installed systems is compared with the coding of the gateway control unit as follows:

• Systems shown in the gateway control unit as installed and which have no fault status are accepted without further checking.

• The fault memories of systems shown with a fault status are read out and the contents saved in the tester.

• Systems entered in the gateway control unit as not being installed are nonetheless checked to see if they are present and whether they have a fault status.

In vehicles without a gateway, checks will be carried out generally for the presence and fault status of all possible systems and their variants.

In the "Vehicle system test" mask (see fig. 6-8) the vehicle systems that may be installed in the identified vehicle are classified in the following groups:

• Powertrain (gateway, engine, gearbox)• Suspension (brakes, distance control, self-levelling system, ...)• Body (dash panel insert, immobiliser, heating, ventilation,

air conditioning, ...)To make the layout clearer, the systems in the individual groups are set apart from one another in the mask by different background colours and a separating line.

You can observe the progress of the vehicle system test on the touch screen. The system currently being interrogated is marked with an arrow on the right in the work window. Identified vehicle systems are marked with a black bar and the colour of the let-tering is inverted. The status of the vehicle system is entered in the column on the right (see table 6-1).

The vehicle system test works through the vehicle systems from top to bottom. Vehicle systems are skipped if they are mutually exclusive with one that has already been identified.

If a control unit contained in the selection list was not identified, e.g. because it was defective, you should select it manually (see section 6.6.1.2 and section 6.6.1.3). Its cor-responding diagnostic data for "Guided Fault Finding" is only made available if this is done. For vehicle systems safely installed in the vehicle (standard fittings for the series), a corresponding message appears stating that the system could not be identified. For vehicle systems "definitely installed" in the vehicle (standard fittings for the series), a cor-responding message will appear saying that the system could not be identified.

After the test has been carried out, the following message will appear in the information field on the left of the mask:

Control units have been interrogated

Page 110: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-16A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.6.1 Possible problems

6.6.1.1 Diagnostic bus faulty

This message (fig. 6-7) appears in the following cases:

• The diagnostic cable is not connected either to the tester or to the vehicle, or the con-nection has come loose at the vehicle end.

• The battery voltage from the vehicle is in a range critical for the tester (see /3/, section entitled "Technical data"). In this case, start the engine or use a battery charger. You can then repeat the communication attempt.

• The diagnostic bus or cable is defective. Perform the self-test (see section 9.6).

Fig. 6-7 "Diagnostic bus faulty" dialog box

If you press Cancel, the vehicle system test will be ended.

Page 111: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-17A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.6.1.2 Definitely installed control unit not recognised

If communication is not possible with a definitely installed control unit, its entry in the list will not be marked and the following message will then appear:

Communication withdefinitely installed control unitis not possible!

Repeat Cancel

If communication is not possible after "Repeat", select Cancel.

You will be given the following message:

Cannot recognise control unit.

To enter it as installed anyway,press "OK".

Select "OK" so that the data applicable to that definitely installed control unit (➚diagnosis objects) will be available.

6.6.1.3 Optionally installed control unit not recognised

If an optionally installed control unit could not be identified, its entry in the list will also not be marked. No message will appear to indicate a non-recognised system.

Check whether optional vehicle systems are installed in the vehicle to be diagnosed and select them as required manually. That is the only way to guarantee that you will be shown the diagnostic data applicable to the vehicle in later masks, in particular in Function/Component Selection.

NoteIf all control units have been interrogated, you must manually select the "Definitely installed control units" afterwards in the "Vehicle system test" mask. Only this ensures that the corresponding diagnostic objects are visible in the functions / components selection.

Page 112: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-18A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.6.2 Observe vehicle system test

While the vehicle system test is running, all buttons on the navigation bar will disappear except the "Help" and "Warnings / notes" button.

After the vehicle system test has been carried out, you can navigate using the "Continue" or Go to buttons.

Pressing the Continue button will take you into the start module if it is available, or to the "Fault memory contents" mask (see fig. 6-9).

The Go to button in this mask makes it possible to access the "Function/component selection" mask for the first time (see section 6.9).

Fig. 6-8 "Vehicle system test" mask with identified systems; test running

Page 113: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-19A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.6.3 Start module

The start module can run automatically in Guided Fault Finding after vehicle identification and before the fault memory entries are displayed. It can contain one or more function tests running separately to the test plan and not entered in the test plan. In this way, it reads e.g. the vehicle identification number (VIN) or checks the software status (flash status) of control units. In some cases, the start module can also request this data from you.

After the start module is closed, processing continues with the "Fault memory contents" mask. Function tests in the start module are listed in the diagnosis log.

Table 6-1 Status symbols in the vehicle system test

Symbol Meaning

Vehicle system display

Normal text Control unit not identified or deselected

Inverted text Control unit identified (recognised)

Status column

� Fault memory empty - no fault set

? The vehicle system entered in the gateway as installed could not be recognised.

Fault Fault set in fault memory

Control unit has no communication interface

Control unit selected manually

Control unit deselected manually

<== Control unit is currently being interrogated

Page 114: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-20A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.7 Fault memory contents

The "Fault memory contents" mask informs you of faults with possible ambient conditions in the electronic vehicle systems. If no fault was detected, the following text will appear in the information window on the left:

no fault recognised

If faults have been detected, they will be sorted by vehicle system and fault code in ascending order ("Standard" sorting).

If a fault (fig. 6-9, fig. 6-10) has been displayed, you are taken to the "Test plan" mask when you press the "Continue" button (see fig. 6-25), otherwise you are taken to the "Complaint report" mask (see section 6.8).

Fault memory contents and their correlations

Fig. 6-9 "Fault memory contents" mask: "Standard" sorting

The scope and structure of the displayed data depends on the build status of the control unit. One by one:

• Number of faultsThe number of fault memory entries read appears at the top in the right-hand informa-tion window.

• Fault codeExample:19461 P3005 035 001 NoteThis is a five-digit fault code followed by an SAE-standard code number, fault type 1, fault type 2 and the possible indicator "Note". Not all blocks are output with every fault code.

Page 115: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-21A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

• Fault code / fault locationThe five-digit fault code indicates the location of the fault - for example "Relay for high heating output - J360".

• SAE numberA code number according to the SAE standard can be assigned to the fault code.

• Fault type 1The three-digit fault type 1 describes the fault symptom more closely - for example, "Short circuit to earth", "Implausible signal", "Lower limit fallen short of", etc.

• Fault type 2Fault type 2 describes how the fault manifested itself - for example, "statically" or "spo-radically". If the mask does not show an entry for fault type 2, this means the fault type is "static".

• NoteThis fault memory entry does not indicate a fault but rather a note.

You can change the fault code sequence by pressing the corresponding sorting buttons. With all types of sorting faults without a sorting criterion will appear at the end of the list, sorted by control unit and marked by a violet background.

There is one special feature to note when sorting is on the basis of the time stamp. Faults which follow another fault within a particular prespecified time span (1 minute, for example) are grouped together and shown with a light blue background. This aims at showing faults and their consequent faults in context. Notwithstanding this, all faults will still be sorted in ascending time order.

Fig. 6-10 "Fault memory contents" mask: "Time" sorting

Page 116: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-22A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

If you press the Ambient conditions button the fault memory entries will be displayed indi-vidually with their corresponding ambient conditions. Depending on the vehicle system these could be standard values and expanded ambient conditions in the form of mea-sured values.

Fig. 6-11 "Fault memory contents" mask: "Standard" sorting (without measured values)

The following ambient conditions can be output:• Standard values (when provided)

The following ambient requirements are grouped under this:− Date, time: Time stamp at the time when the fault was detected.− Odometer reading (mileage): Shows at what odometer reading the fault was de-

tected.− Priority: The priority can have a value between 0 and 15:

0 - 5: fault ID with descending priority; 5 = fault with lowest priority6 - 8: note, no fault.

− Malfunction occurrence counter: The counter can have a value between 0 and 254. Every time the fault occurs (through all driving cycles) the counter is incre-mented by 1.

− Unlearning counter / driving cycle: Indicates the current counter status of the ➚unlearning counter. When a fault occurs, the unlearning counter is set to a con-trol-unit- and fault-code-specific value - for example, 40. If the fault does not occur during the next driving cycle it is marked as "sporadic". Every subsequent driving cycle without a fault decrements the unlearning counter by 1.

Page 117: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-23A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

• Measured values (when provided, additional ambient conditions)Measured values can also be displayed exclusively or additionally for the individual fault codes. The ambient conditions (which may number up to eight) can in each case consist of a default value and up to seven measured values, or up to eight measured values without a default value.

You can control the display via the buttons on the right-hand part of the work window:• Position

The first fault in the list displayed together with its ambient conditions takes the 1st position. You can navigate between the faults by means of the two arrow keys.

• SortingWhen the mask opens, the setting is always "Standard". With the displayed buttons you can however switch sorting over to different criteria:

Sorting by standard:When you press the "Standard" button the faults are sorted in ascend-ing order by:• Fault code• Time• Odometer reading• Priority• Frequency of occurrenceSorting by odometer reading:When you press the "Kilometer" button the faults are sorted by the odometer reading, starting with the lowest. Fault codes without kilo-metre indication appear at the end of the list in the order in which they were read from the fault memory.Sorting by static / sporadic:When you press this button, first the static faults are displayed sorted and then the sporadic faults.In the static faults group, the tester sorts by the change frequency of the malfunction occurrence counter starting with the lowest value (fault hardly changed to sporadic - in other words, behaves virtually statically). With sporadic faults sorting begins with the highest value.Faults which appear in the malfunction occurrence counter are fol-lowed by faults not in the counter or with a value of "0".Sorting by time:If you press the "Time" button the faults are sorted by the time stamp, starting with the earliest. Fault codes without a complete time stamp (date, time) will appear at the end of the list in the order in which they were read from the fault memory.

Page 118: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-24A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Note about ➚➚➚➚ASAM-ODX control unitsThe previous examples apply to control units with ➚KW1281/2000/6000 protocol. Under ASAM-ODX there is only the 2nd fault type. Appropriate contents of fault type 1 are already included in the fault code / fault location. Usually, only the SAE code is displayed as fault code on the tester.The ambient requirements displayed may also differ here.

Page 119: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-25A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.8 Complaint report

The "Fault memory contents" mask (see fig. 6-9) is automatically displayed if no faults were recognised in the vehicle systems and you then pressed the Continue button. Entering complaints is another option for entering fault symptoms.

The "Complaint report" masks contain predefined lists of terms from which you can select the complaints reported by the customer or observed by you yourself. You can input several complaints from each of the two groups, "Technical problem solution" and "Repair group". The groups differ in the following way:

• Technical problem solution: Here the complaints are sorted by solutions to the prob-lem behaviour as currently known (function, fault number, and so on).

• Repair groups: Here the complaints are sorted by vehicle structure and the symptoms you have noticed (drive, engine, performance, and so on).

You should enter as many of the known fault symptoms as possible in order to describe the complaints. You can also enter complaints if there are already entries in the fault memory. You can reach the input screen for complaints by selecting the "Complaint report" item in the "Go to" menu.

You can select one element from the lists of terms on each mask. As each term is selected, it is immediately accepted and the screen switches to the next mask. You can use the Back button to jump back to the previous mask at any time and change the selection on that mask. The steps selected are displayed one after the other in the infor-mation window on the right-hand side of the masks.

If the "Overall selection display" mask appears, you can accept the new selection and select the already existing one for deletion. Only complaints appropriate to the vehicle will be presented for selection.

You do not always have to specify something at all levels of a given complaint. As soon as the Continue button appears, you can switch over to the "Overall selection display" mask (see fig. 6-14). In this case all of the syptoms coming under the step last reached will be included in the test plan.

Page 120: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-26A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Example of the mask sequence for "Complaint related to repair group":

Fig. 6-12 "Select complaint" mask

Fig. 6-13 "Select subsystem / observation" mask

Complete the complaint by selecting further phrases.

Page 121: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-27A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

The Accept button appears when you have entered the complaint completely. It will be displayed again in the information window on the right. If you press the Accept button, the complaint will be accepted into the "Overall selection display" (see fig. 6-15).

Fig. 6-14 "Overall Selection Display" mask (ready for accepting the complaint)

You can formulate further complaints. Use the Back button to go to the point in complaint input where you wish to make entries.

Fig. 6-15 "Overall Selection Display" mask (with "Continue" to test plan)

Page 122: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-28A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

By pressing the Continue button, you will leave the "Complaint report" function and switch over to the "Test plan" mask. As you switch over, the tester will prepare the test suggestion that matches the symptom and will enter it in the test plan.

If suspect components have already been entered in the test plan, a Yes/No question will appear to ask whether you want to replace the current system test plan with a new one. Select "Yes" to enter the suspect component that matches the complaint into the test plan.

Fig. 6-16 "Overall Selection Display" before accepting the symptom

Page 123: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-29A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Fig. 6-17 Test plan with test suggestion based on an entered symptom

The rest of the procedure is as described in section 6.10.

At any time, you can view, delete or add to entered complaints by selecting "Go to", "Complaint report", "View/delete complaint report".

The system and the matching suspect component appear here

Page 124: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-30A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.9 Function/Component selection

The "Function/Component selection" function gives you the option of applying your own personal expert knowledge in the context of Guided Fault Finding. Here, in contrast to the evaluation of fault memories (see section 6.7) or complaint reports (see section 6.8), you directly select functions or components that seem suspect for testing.

In addition to function tests, other functions, documents (see section 6.9.1) and informa-tion may also be stored here, which do not belong to the fault finding, such as e.g.:

• Customer service functions (coding, reading measured values, ...)• Information / documents on testing equipment, tools• Information on fuse / relay configuration

After the functions and/or components are selected, the tester automatically allocates the relevant function tests to them. In this way, you compile your own "User test plan". The names of the selected functions or components appear in the "Test plan" mask under "User test plan" (see section 6.10), if there are already system-guided test sug-gestions available. This is presumed for the example which follows.

The "Function/Component selection" mask is accessed from the "Vehicle system test" mask by pressing the Go to button. Function, repair group, component group and com-ponent are selected from lists displayed over several masks, similar to the procedure for the complaint report (see section 6.8).

When selecting functions and components, the screen layout develops in the form of lev-els, with each level distinguished by an indent to the right when compared with the previ-ous item selected. If a row is proceeded by the "+" symbol, this indicates further options for selection. Example:

+ Powertrain+ ADR engine

+ 01 - Systems capable of self-diagnosis

+ Electrical componentsetc.

NoteThe only functions and components definitely displayed are those for vehicle systems marked in the "Vehicle system test" mask (fig. 6-8), i.e. those that were automatically identified or manually selected.

+ Motronic engine management system

Page 125: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-31A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Each indent signifies a selection in a mask. If you want to jump back one level, select a higher level (not the Back button since this takes you directly back to the test plan!). Example:

+ Powertrain+ ADR engine

+ Motronic engine management system

Example of a "Function/Component selection" mask sequence:

Fig. 6-18 "Select function or component" mask, 1st level

Select "+ Drive", for example. The next mask will be shown automatically when the selection is made. Specify the function or component in more detail in the masks which follow. If you want to change your selection, touch the preceding selection.

+ 01 - Systems capable of self-diagnosis

Page 126: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-32A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Fig. 6-19 "Select function or component" mask, 4th level

NoteIf you do not go through all of the steps, – after the confirmation of a message – all of the components and functions coming under the step last reached are included in the test plan.

Page 127: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-33A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

In this submask, select the desired component or a function. The selection will be displayed until you touch "Continue", which will take you to the test plan.

Fig. 6-20 "Select function or component" mask, 5th level

The selected diagnosis object is added to the "User test plan".

Fig. 6-21 "Test Plan" mask with "User Test Plan" section

The rest of the procedure is as described in section 6.10.

Page 128: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-34A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.9.1 Documents

Available documents, such as installation locations, pin assignments and so on, can be selected and displayed in the "Function / component selection" mask. For this purpose, select the relevant function / component and then the Go to destination "Documents". After the first selection, the Go to destination "Documents" is available for selection per-manently in the Go to Destination menu.

Documents (graphics, text) are displayed in the work window. If they are larger than the work window, they will be provided with a vertical scroll bar.

Documents are also found in the function test masks. There they are made available directly via a row of up to six numbered and correspondingly labelled buttons (see section 6.11.1).

Example of a mask sequence arising from "Function/Component selection":

Fig. 6-22 Function/Component selection, "Documents" selected as "Go to" destination

You can activate the "Select document" dialog box for a selected function or a component via the "Go to" destination menu.

NoteIf you selected a diagnosis object in function/component selection, you can also access its documents directly by selecting "Documents" from the "Go to" menu during the ongo-ing function test. The documents presented here do not form part of the current function test, but rather the last selected function/component selection.

Page 129: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-35A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Fig. 6-23 "Select Document" dialog box

The documents that can be displayed are listed in the "Select document" dialog box. Select the desired document, and press the Display button. The document will then be displayed.

Fig. 6-24 "Display Documents" with hotspot (red frame)

The displayed document can contain hotspots (sensitive rectangular areas). If you touch a hotspot on the screen, you will be shown the document associated with it.

Sensitive area

Page 130: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-36A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.10 Test plan

When the transition is made to the "Test plan" mask, the results of the previously run "Fault memory contents", "Complaint report" and "Function/Component selection" masks are evaluated, and a test suggestion is created from that and shown as a list (see fig. 6-25). The priority of the tests is expressed in their sequence. In the actual example, the contents of the fault memory lead to a test suggestion that is entered in the test plan and preselected there. Pressing the Continue button will begin the marked function test.

Fig. 6-25 System test plan and user test plan with several suspect components

The test plan shows one or several symptoms (blue font) above the suspect module or function (diagnostic object). The diagnostic object is preceded by a status (see table 6-2). If you select it and press "Continue", an appropriately linked function test is started. Afterwards, the status of the diagnostic object is updated. In addition, the function test can enter new diagnostic objects in the test plan or set existing ones to "OK". Diagnostic objects entered in the test plan by a function test, appear directly under the previously selected diagnostic object - slightly to the right.

You do not always have to adhere to the suggested sequence of the function tests. Rather, you can deviate from it at any time and select a different test in the automatic or user test plans (included via the functions / components selection, see section 6.9) as the next function test.

Symptoms (blue)

Suspected components or functions

Component status

Page 131: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-37A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

The "static" or "sporadic" (fault no longer present at the moment) fault type plays a role for the sequence of the diagnostic objects. If only sporadic faults are assigned to a diag-nostic object, they are placed at the end of the test plan. When you start the function test of such a diagnostic object, the following message may appear:

Sporadic faults occurred.(possibly additional text)

Would you like to see the details?

If you confirm with "Yes", the corresponding fault memory entry is displayed along with the ambient requirements (if available).

When all the function tests for the diagnostic objects entered have been performed, the test plan is considered to have been processed. You can also repeat function tests by reselecting the diagnostic object and pressing "Continue".

The status preceding the diagnostic object corresponds to the current status of the func-tion test or the result of the linked function test.

"OK" means, for example: the function test was performed without any faults; the diag-nostic object (module or function) is OK.

Page 132: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-38A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Table 6-2 Meaning of symbols for the status of the diagnostic objects

Symbol Meaning: function test

- Not yet carried out

OK OK

OK! This status is a special case: A function test may end with the status "Diagnosis generated and component repaired". In this case, the tester does not go back to the test plan after completing the function test, but asks the question:

Repeat test after repair is completed?

If you answer with "No", the status "OK" (already repaired, result not checked) is entered in the test plan in front of the diagnostic object. If you answer with "Yes" instead, the function test is repeated in verifica-tion mode (examination of the repair). However, this concept requires appropriate program components in the function test, e.g. a short test. If these program components are not available, the entire function test is repeated and the reaction is the same as during the initial activation.You can also start the verification of a function test from the test plan by the repeated selection and start the "Test" selection.

OK? Probably OK.It is not possible to make a statement with 100 % certainty about the result of a particular function test, since e.g. not all the results are testable.

X Not OK.

? Result unknown or cancelled

⇒ Currently being carried out

Page 133: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-39A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.11 Function test

A defined function test has been assigned in the test plan to every vehicle function, every component group and every component (diagnostic object that could indicate a fault). Its task is to test the requirements defined for each. It yields the results "OK", "Not OK" or "Test result unknown".

A mask from a function test is shown in fig. 6-26. Every function test consists of a num-ber of self-contained test steps which can also be repeated via the "Go to" menu after they have been executed. The information window on the left contains the title of the function test, while the name of the test step currently being processed is displayed as a heading in the work window.

A function test can include the tester's communication via the diagnostic bus, as well as measuring instructions. You become actively involved in the process at this point, e.g. to connect measuring leads, to make decisions or to enter values. For this purpose, the tester will provide you with up to two rows of appropriately labelled buttons in the work window, for example. The left row contains the buttons for further processing of the test dialogs (see section 6.11.1); the right row contains up to six numbered buttons for displaying documents.

After the function test is finished, the tester will return to the "Test plan" mask. There, you can select the next diagnostic object and start its function test or access alternative diagnostic procedures via the Go to Destination menu (such as complaints or function/component selection).

NoteSince, unlike the VAS 5051 / VAS 5051B, the VAS 5052 does not have any internal test-ing devices (e.g. multimeter, oscilloscope) external testing devices must be used and measurement results transferred to the function test via replacement value input.

Page 134: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-40A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

In this example of a function test, a question appears after starting:

Fig. 6-26 Function test, question to the user

Different masks appear later in the course of the function test depending on the actual tests done, e.g. a message with the Done button:

Fig. 6-27 Function test, message for the user

Page 135: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-41A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Select the "1. Fitting location" button, for example. You are immediately shown the matching image document (see fig. 6-28).

Fig. 6-28 Document display, "Fitting location" example

Use the Back button to switch back to the previous mask, and use the Done button to continue the test there after dealing with the message.

One element of the function test shown in the example is a resistance measurement. The corresponding mask (see fig. 6-29) contains instructions as to which measuring points the measuring lead should be connected to. Press the "Measure" button to start the cyclic measurement on the VAS 5051 / VAS 5051B. If you press the "Measure" but-ton again, the value last measured is retained. Press "Continue" to continue the function test. You can also use this button to cancel an active cyclic measurement directly and continue the function test with the value last measured.

NoteThe button on the probe tip triggers the same function as the "Measure" button on the screen. It is recommended to use it if the tester screen is not visible or accessible from your working position on the vehicle.

Page 136: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-42A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Fig. 6-29 Function test, Resistance measurement

Replacement value input

If no measurement is possible or if an external testing device must be used for the meas-urement (VAS 5052), you can enter the value manually. To do so, touch the results field (fig. 6-29). A numeric keyboard will appear for entering replacement values. On the VAS 5052, the virtual keyboard also appears after the Measure button is pressed.

Fig. 6-30 Virtual keyboard for entering measured values

Enter the measured value. The "Q" button is for applying the value you entered.

At the end of the function test, the Guided Fault Finding application switches back to the "Test plan" mask (see fig. 6-25) and presents you with any more suspect diagnostic ob-jects for testing.

Result field and activation of the replacement value input

Page 137: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-43A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.11.1 Test dialogs

In the function test, you will find the following types of user/test dialogs:

• Messages to the user with the Done button for continuing with the program.• Questions to be answered with the buttons "Yes", "No" or the additional button

"Unknown".• Decisions with up to eight buttons for branching off on separate program paths.• Measuring instruction with the Measure button for starting and/or stopping the cyclical

display for the measured value.• Displays of results from a control unit with the Read button for starting and/or stopping

the cyclical output of those results.• Displays without a special button for cyclical program runs (loops) and for any cyclical

output of texts or values. A cyclical loop is interrupted either by the test program or by pressing a button.

• Input instructions for entering a numerical value or text via a keyboard that appears on the screen.

All test dialog steps are only concluded when a button appropriate to the activity is pressed, e.g. "Done", "Yes", "No" etc.

All test dialog steps can include buttons for displayable image documents. They are dis-played by pressing the corresponding button, switching to the document display and then back to the test dialog step.

6.11.2 Measuring instruction (multimeter)

The work area of the "Function test, G62 - Sender for coolant temperature" mask (see fig. 6-29) contains a display of the type of measurement ("Resistance measurement"), the instruction for connecting the measuring lead, an optional description of the mea-surement ("Resistance measurement on sender for coolant temperature (G62)"), and the specification of the target value and the measured value as a bar display and as a numerical output.

The bar display contains a numbered scale. A rectangle indicates the range of tolerance for the measured value. The measured value appears as a coloured horizontal bar on the numbered scale. If the value is OK (green), the bar will jut into the tolerance window. A red bar indicates an incorrect measured value; the display "+++++" indicates an over-load.

The numerical display also includes the physical unit of measurement.

Measurements of numerical values are triggered by pressing the Measure button after the specified connections have been set up.

Page 138: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-44A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

VAS 5051:

The measurement is repeated several times in a cycle, as long as the "Measure" button is pressed; the last value measured is accepted after the "Continue" button is pressed. Pressing the Measure button again stops the continuous measurement, and the last value displayed will be kept.

The Measure button can alternatively be activated via the switch in the red probe tip.

If the internal testing device is defective or if you prefer a testing device of your own, you can enter the measured value thus determined via a keyboard on the screen. The key-board appears automatically when the results field is touched or if the internal Test Instruments are malfunctioning. It will disappear again after entries have been made when the buttons Q or Continue are pressed, or, if a genuine measurement is carried out, by pressing the Measure button. The physical unit for the entry (e.g.: V, mV) is pre-set automatically.

VAS 5052:

Here, a numerical keyboard appears when the Measure button is pressed, for entering a measured value.

Page 139: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-45A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.11.3 Measuring instruction for vehicle systems

The vehicle systems supply a wide variety of measured values relevant to diagnosis which can be interrogated and evaluated in a function test by so-called "measuring instructions". In some cases measuring results are displayed in a message (fig. 6-31) or directly from the measuring instruction.

Measuring instructions to vehicle systems require functioning communication with the ve-hicle system in question.

6.11.3.1 Measuring instruction results in a message

As a rule measurement results are displayed in messages. Here the measuring instruc-tion itself runs invisibly in the background.

Fig. 6-31 Function test, message with measurement from vehicle system

fig. 6-31 shows a message which is incorporated in a loop in the function test. Every time the loop runs, the measured value is read from the vehicle system and updated in the mask. It is not possible to input a replacement value here.

Page 140: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-46A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.11.3.2 Measuring instruction with direct output

In some special cases measuring instructions with vehicle systems are also programmed as direct output. The display is similar to the measuring instructions for multimeter appli-cations (see fig. 6-29), but with the following differences:

• Since it only uses internal measurements of the vehicle systems, it can also be ac-cessed on the VAS 5052 without restrictions.

• Instead of the Measure button a Read button is displayed. If vehicle communication is possible, while it is activated the selected measured value is displayed cyclically in the result field.

If vehicle communication is not working, you can input a replacement value manually. Touch the result field (see fig. 6-29) to access the virtual numerical keyboard and input the replacement value. Next press "Continue". The Read button is not used in replacement value input.

6.11.3.3 Measured values table

This provides another way of displaying measurements from vehicle systems. The func-tion test can present you with a measured value list for selecting measured values or a preselected selection of measured values for displaying the results.

Selecting measured values from a measured values table

This display allows you to select the desired measured values yourself from a measured values table. The display groups are given different coloured backgrounds to make it easier to differentiate them. Each entry consists of a group number, the number of the display field (not with ASAM-ODX) and the measured value name.

The measured values of different control units are given different colours to make it eas-ier to differentiate them.

After selecting at least one measured value, press the "Ready" button which takes you to the next mask where you can perform the measurement.

Page 141: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-47A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Fig. 6-32 Function test, read measured values

Carrying out measurement

You can go to this mask directly from the function test or via the selection list of the measured values table (fig. 6-32). There can be any number of measured values. The "Result" column initially is empty. Press the Read button to read the measured values cyclically from the vehicle system(s) (fig. 6-33).

Selecting individual measurements

You can select a single line. With this, the name of the measured value and the result are displayed again in the long information bar in the lower part of the work window. At the same time, a "Message text" button and/or a "Test program" button may appear on the right (not illustrated).

• Message text: Information about the measured value is provided here.• Test program: If a result is outside the specified value and you select the relevant

measured value, a function test for finding faults may be offered when you press the "Test program" button. If you press this button, the function test is entered in the test plan; an appropriate message is displayed. You can activate this test after the current test.

Page 142: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-48A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Press the "Go to" button to jump back to the selection list "Measured values:Read meas-ured values"where you can make another measured-value selection. Press the Continue button to continue with the function test. In some cases the measured values table is quit automatically - such as when, for example, all values are OK.

Fig. 6-33 Function test, measurement in progress

NoteThe display frequency of the results corresponds to that in Vehicle Self-Diagnosis if the measured values to be displayed belong to a display group. Displaying measured val-ues from different display groups and control devices will have a negative effect on time behaviour and synchronization.

Information bar

Page 143: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-49A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.11.4 Digital Storage Oscilloscope (DSO) measuring instruction

VAS 5051 / VAS 5051B:

The DSO measures graphical curved lines cyclically using parameters preset by the function test and displays them. Press the Freeze Frame button to pause the cyclical repetition of the measurement. The last display will freeze on the screen. Press the Freeze Frame button again to start the cyclical repetition of the measurement up again. The "Freeze frame" button can also be operated by activating the switch in the red probe tip of the measurement cable.

With measurements that are triggered by a particular condition (i.e. events), the Measure button is used to enable triggering. The measurement is then automatically initiated when the trigger event occurs.

The measurement instruction is followed by a question regarding the evaluation of the signal curve.

VAS 5052:

A DSO measurement must be carried out using an external device.

6.11.5 Cancel function test

Normally, you can only move from the "Function test" mask to the "Test plan" if all operator entries have been properly concluded and a clear test status has been achieved. Missing information or operator actions that are still outstanding are displayed via messages.

Nonetheless, you can cancel an ongoing function test in the following way:

1. Use the "Go to" destination menu to switch over to the "Test plan" mask.2. There, select the ongoing function test and press the Continue button.3. In the dialog which appears, press the "Abort function test" button. Note that the status

"?" - that is, "unknown" - will now be entered next to the function test.

Page 144: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-50A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.12 Leaving the Guided Fault Finding application

You leave the Guided Fault Finding application via the functions contained in the "Go to" destination menu. These include:

• Interrupt,• Cancel and• Exit.

The "Interrupt" function is only offered if you have accessed the "Test plan" mask at least once. The "Cancel" function is offered from the "Select type" mask onwards.

Fig. 6-34 Leaving the Guided Fault Finding application via "Go to" destination

Before returning to the start mask (in the case of Exit) or to the basic screen for Guided Fault Finding (in the case of Cancel), you will go through various additional run sequences ("Interrogate fault memory", "Generate readiness code?", end module) (see section 6.12.2, section 6.12.3 and section 6.15).

Page 145: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-51A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.12.1 Interrupt

You can interrupt the diagnosis session for a short break (pause) or save your work to continue with it at another time.

Fig. 6-35 Work interruption dialog box

6.12.1.1 Interrupt work briefly (pause)

After the "Interrupt" function is activated within the "Go to" menu, a dialog box appears where you can choose whether you want a short pause or a longer interruption. If you choose the short break, the following text will be displayed:

Work has been interrupted for a short time (Pause).Press "OK" to end pause.Do not cancel pause without consent orgood reason.

When the OK button is pressed:Work can be continued in the current mask.

Page 146: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-52A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.12.1.2 "Interrupt" work for a longer period (save job)

You can interrupt a diagnosis job and save all relevant diagnostic data up to that point in the tester for later retrieval by specifying a job code. After saving, you will automatically switch over to the first mask of Guided Fault Finding.

After saving, you can activate any other diagnosis functions.

Enter ➚job code:

Fig. 6-36 "Enter job code" dialog box

You can use the "Enter job code" dialog box to enter a job code via an onscreen keyboard for the diagnosis job that is to be saved, and acknowledge it with the Q button. The current date and time will also be saved, alongside the job code.

Page 147: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-53A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.12.1.3 Load diagnosis job

You can reload saved diagnosis jobs in the masks of the basic features (type, model year, body version, motor). To do so, select the "Diagnosis job" function in the "Go to" destination menu. Choose the desired job and select "Edit". An instruction follows with the job name and the corresponding vehicle that must be connected. When you acknowl-edge the instruction with "OK", the "Test plan" mask will follow. It shows the status achieved for the interrupted diagnosis job when it was saved.

After the saved diagnosis job is loaded, the saved item will be deleted. Therefore, you should save the diagnosis job again if you need to, in which case it will be stored again under the same name.

Example for a "Load diagnosis job" mask sequence:

Select "Diagnosis job" as "Go to" destination:

Fig. 6-37 "Select type" submask, "Diagnosis job" selected as "Go to" destination

NoteThe top right-hand information window shows the name of the loaded job instead of the loaded brand data.

Page 148: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-54A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

Fig. 6-38 Diagnosis job, "Use / delete interrupted job"

Select the interrupted diagnosis job and press the Edit button.

Fulfil prerequisites and press "OK":

Fig. 6-39 Diagnosis job, "Job Administration" dialog box

Press the OK button to leave the dialog box and switch over to the test plan (see section 6.10).

Page 149: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-55A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.12.2 Cancel

The Cancel function corresponds to the Exit function with the difference that you return to the basic "Select brand" mask of Guided Fault Finding. In other words, you remain in the Guided Fault Finding operating mode. With Exit, the Guided Fault Finding operating mode is exited and you go to the start mask.

6.12.3 Exit

You can leave Guided Fault Finding using the Exit destination in the "Go to" destination menu. A question appears with information for exiting and the answer options "Do not exit", "Diagnosis log" and "Exit".

Select "Do not exit" if you want to continue working instead. Select "Exit" to initiate the return to the start mask. All operating modes will be closed.

Before returning to the start mask, all vehicle systems identified will be tested again by a system test. If there are faults set, the fault memories will be erased and then read out again, to display any static faults that may be present.

If there is still a fault memory set, the following message appears:

All fault memories have been erasedHowever, relevant faults are still set or have been set again.

Therefore, if you want to restart the "Fault memory contents" mask,press "OK".

If you still want to cancel or exit,press "Cancel".

You now have the option of continuing with Guided Fault Finding or of exiting the pro-gram. Before you really do quit, a stop module (if present) will also be started (see section 6.15) and you will be asked if you wish to print the diagnostic log.

Page 150: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-56A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

OBD vehicles

In the case of OBD vehicles the readiness code will be checked after the system test or before the stop module runs. If this code is deleted or incorrect, how next to proceed is dealt with in the case examples:

Example 1: Faults were set in the engine control unit

When the fault memory was erased, the engine control unit's readiness code was also erased. The following message then appears, with a Yes/No question:

The readiness code has been erased. Do you want to generate the readiness code again now?

If the answer is "No", the readiness code remains erased. If you select "Yes", the function test for generating the readiness code will be started.

After the function test has ended, it will be entered with a status symbol in the "User test plan", which will then be displayed. You now have the option of continuing with Guided Fault Finding or of cancelling it again via "Go to/Exit".

The readiness code query will only be shown if there is a corresponding function test available for generating the code.

Example 2: No fault set in the engine control unit

When diagnosis is exited, the engine control unit's readiness code is interrogated. If it is not OK, a note appears with the question:

The readiness code is not OK. Do you want to generate the readiness code again now?

If the answer is "No", the readiness code remains unchanged. If you select "Yes", the function test as per Example 1 for generating the readiness code will be started.

NoteCurrently, the readiness code is only evaluated for an engine control unit.

Page 151: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-57A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.13 Diagnosis log

If you have accessed the "Test plan" mask at least once, you can use the "Print/diagnosis protocol" function to print out a Guided Fault Finding protocol or save it to an external storage device. In the latter case, you must enter the vehicle ID number and the license plate number in the print menu, provided the data is not already known from the diagnostic procedure. For printing, refer also to (see section 3.5).

Prior to the actual output, you are asked whether you would like to output the diagnostic protocol in short or in complete form.

The "Diagnostic protocol" function is also offered after the end of the stop module by means of a dialog box.

The complete diagnostic protocol contains the following information:

• Workshop code, dealership identifier• Version of the currently installed software system (base CD, brand data and vehicle

project name / version of the ODX run-time data for ASAM-ODX control units)• Licence plate number and vehicle ID number, if available• Vehicle brand and identification characteristics (➚basic features)• Time required for diagnosis in VW units of time (➚time record for the diagnosis ses-

sion, derived from the sum of fixed values and actual time required)• Event memory: List of the detected vehicle systems, their identification data and fault

status. If there is a fault, also their fault memory contents with possible ambient re-quirements

• Work steps performed (list of the main actions in running order), such as:beginning of diagnosis, vehicle identification, vehicle system test (selection), vehicle system test (performance), event memory (fault memory contents), test plan, function tests1 including start and stop modules, beginning and end of an interruption (saving and loading of a diagnosis session)

• Numbered test plans corresponding to the work steps, each subdivided into system test plan and user test plan (where these exist)

• Function tests that have been carried out, numbered according to the work steps listed. The title of a test according to the test plan can be taken from the work steps. All test steps run will be logged, with message output, results and dialog decisions. The communication jobs with control units and their results will be listed under "Diagnosis". The sections "Beginning sub-function: …" and "End sub-function: …" show subprograms loaded during the function test.At the end of a function test, the full results will be displayed according to the test plan, e.g.: "Function test OK".

1. With the ID code. For tests from the test plan, also with the title of the corresponding ➚diagnostic object, as entered in the test plan.

Page 152: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-58A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

• Malfunction messages of the run-time system are listed together at the end of the pro-tocol. Messages that were generated during the processing of the test plan are listed under "Diagnosis job".

Short form

The short diagnostic protocol does not contain any list of the test plans and function tests.

6.14 Function test log

The "Print/function test protocol" function corresponds to a different short version of the "diagnostic protocol". The list of work steps and test plans is left out and only the last func-tion test carried out is logged.

6.15 Stop modul

The stop module is automatically started when you quit the Guided Fault Finding applica-tion and can contain one or more function tests (also see section 6.1).

Once the stop module has finished and before the diagnostic session finally terminates you will be asked whether the diagnostic log should be output. The diagnostic log thus out-put also includes the progress of the stop module function test.

Page 153: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Fault Finding

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.6-59A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

6.16 On-line feedback log

During a function test or in the stop module of the Guided Fault Finding application and depending on the vehicle and manufacturer, a diagnostic protocol or a fault protocol may be sent to the vehicle manufacturer. The tester must be connected to your workshop net-work for this function.

The online feedback protocol can contain data such as the number of the vehicle (VIN), the number of the tester (equipment no.), the dealership identifier and the fault memory contents read out for all control units. Questions may also be displayed, e.g.: "Was the repair successful?"

If the tester is not connected via the VW workshop network, you need to enter the login for the online connection.

Aborted or unsent online feedback protocols are kept on the tester for up to forty days. On starting, the tester checks whether protocols have been saved and whether there is a net-work connection. If that is the case, the tester offers to send the saved protocols now.

Page 154: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Functions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.7-1A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

7 Guided Functions

7.1 Overview

Some function tests correspond to vehicle-specific, customer-service-oriented tasks, such as adaptations, coding, and so on. The Guided Functions operating mode allows you to access these tests directly, after vehicle identification (without always having to run the vehicle system test). Fault-finding programs are not provided here, start and stop modules do not run.

These tasks can also be accessed in Guided Fault Finding after the vehicle-system test and selection of function / component selection.

The run sequence described in the following is depicted in fig. 7-1.

(1) Start mask

Guided Functions is launched from the start mask (for further information, see section 7.2).

(2) Vehicle identification, ➚gateway installation list, ➚basic features

After activating the Guided Functions, you must enter the brand and the vehicle identifi-cation (type, year of manufacture, variant and engine code (basic features)) as in the Guided Fault Finding, and confirm them. Depending on the type of vehicle, automatic or mixed vehicle identification of the basic features may be possible.

(3) Display vehicle systems

The vehicle systems for which Guided Functions are available will be displayed.

(4) Select vehicle systems or function

Select the desired vehicle system or function.

Page 155: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Functions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.7-2A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

(5) Identify vehicle system, interrogate fault memory

When you select a function, only the control unit that relates directly to it is control unit identified automatically and its fault memory read. Questions to help clarify possible vari-ants could be displayed as well. Press the "Vehicle system test" button to display the control unit which has been identified. A complete vehicle system test will not be carried out here but it can still be launched with the "Start system test" button in the "Vehicle sys-tem test" menu. In the case of non-automatic identification of control units, here too it is possible to make a manual selection of individual control units.

(6) Fault memory entries available?

If a fault is detected when the control unit is interrogated, this message will appear:

Malfunctions were detected, the troubleshooting for this can be performed by switching to GFF!

When you acknowledge the message, function selection will continue. However, switching to Guided Fault Finding to locate the faults is recommended.

You can see which faults occurred by pressing the "Vehicle system test" button and then "Continue". You then return to continuing your function selection by pressing "Continue" once again.

(7) Display vehicle systems, selection of further functions

Further function selection is handled the same way as function / component selection in Guided Fault Finding. You can go back to a higher level of function selection by select-ing the corresponding level on the same mask.

You can use the operating mode button to switch to the operating modes Test Instru-ments (VAS 5051 / VAS 5051B only), Vehicle Self-Diagnosis or Guided Fault Finding. Here, quitting and returning to the start mask is only possible from Guided Functions (from the original operating mode).

(8) Enter functions in test plan, function test

After a function is selected, it is entered in the test plan. The procedure from that point on is identical to that in Guided Fault Finding (see section 6.10).

(9) Perform function test

Carry out the function test. The function appears with its status in the test plan. From there, you can use the Back button to switch back to the "Select function" mask.

Page 156: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Functions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.7-3A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Switching operating mode

When you switch to the Guided Fault Finding operating mode, the identification that has already been carried out will be noted and utilised. The same applies when you switch between the operating modes "Guided Fault Finding" and "Guided Functions".

The protocols are continued when you change the operating mode. The same protocols apply to both operating modes.

Print functions

The following print functions are available:

• Screen (see chapter 3.5)• Diagnosis log (see chapter 3.5, section 6.13)• Function test log (chapter 3.5, section 6.14)The print functions correspond to those of Guided Fault Finding.

Page 157: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Functions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.7-4A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Fig. 7-1 Sequence of the "Guided Functions" operating mode

Guided functions

Display vehiclesystems

Identify vehiclesystem, interrogate

fault memory

Display functions forvehicle test, select

function

Enter functions in testplan

Select brand, basicfeatures

Select vehicle system/function

Function test

Are fault memory entriesavailable?

Recommend GuidedFault Findingyes

no

1

2

3

4

5

6

7

8

9

Actualize test status

Forward

Return

fig. 7-2

fig. 7-4

fig. 7-3

fig. 7-5

Page 158: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Functions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.7-5A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

7.2 Guided Functions run sequence

Guided Functions is activated by pressing the button of the same name in the start mask.

Fig. 7-2 Start of Guided Functions

It starts as in Guided Fault Finding (section 6.4), with selection of the brand and definition of the basic features (type, model year, variant and engine code), either automatically (with gateway) or manually.

After confirming the vehicle identification, you may have to answer questions about the variants for vehicle fittings. In the mask that then follows, the vehicle systems are presented for selection (fig. 7-3).

Page 159: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Functions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.7-6A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Fig. 7-3 Selecting vehicle system or function

After the vehicle system has been selected, the tester sets up communication to the vehicle system in order to identify it and subsequently read its fault memory. If there are entries in the fault memory, Guided Fault Finding is recommended. It uses a knowledge base to relate fault memory entries to components and can therefore generate a test plan automatically.

Fig. 7-4 Fault memory entries in the selected vehicle system

Page 160: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Functions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.7-7A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

When you press the OK button (see fig. 7-4) or, depending on the situation, answer any questions there may be about ➚variants, the functions available for the vehicle system will be displayed.

Fig. 7-5 Functions that can be selected for the vehicle system

After selecting the function and pressing the Continue button, you switch over to the test plan. There you can carry out the corresponding function test that will perform the customer service oriented task. The procedure in the test plan corresponds to that in Guided Fault Finding (see section 6.10).

Page 161: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Guided Functions

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.7-8A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Fig. 7-6 Test plan (after carrying out the function)

Page 162: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Applications

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.8-1A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

8 Applications

8.1 Overview

This operating mode is not available to the VAS 5053.

In the operating mode Applications there are further applications whose programs and data are loaded directly from ➚CD or by previous installation on the tester (see section 9.23).

Application examples:

• Start application from CD-ROM (e.g. Update programming for control units)• Service training (VAS 5052, VAS 5051B)

8.2 Starting application

Press the Applications button on the Start screen.

Fig. 8-1 Start screen, call Applications

Page 163: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Applications

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.8-2A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

You get a selection mask (fig. 8-2) with a list of the presently available applications.

Fig. 8-2 Selection mask without additional applications installed

Starting application

• Select the desired application (regarding installation of applications, see section 9.23) and start it by pressing the Continue button

or

• insert the CD containing the application required if this is to be started directly from CD rather than installed on the tester. Then, select "Start application from CD-ROM".

NoteAfter starting an application, this runs autonomously and independently of the ➚process system of the tester. The selection mask of Applications is only available again after you have ended the application.Additional details may be found in the information enclosed with the applications.

Page 164: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Applications

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.8-3A5E00330054/030

VAS 5052

VAS 5051B

VAS 5051

8.2.1 Starting application from CD-ROM

In the "Start application from CD-ROM" application you can launch an application of any kind which is on CD - such as a flash CD for updating control unit programming, for ex-ample - provided it is not executed via the "Update programming" diagnostic function (if necessary, please refer to the printed information enclosed with the CD).

8.2.2 Service training

The application "Service training" is here used as an example.

Page 165: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-1A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9 Administration

9.1 Overview

The Administration provides you with functions for internal administration of the tester. Use the following table to find out which functions are available on your tester.

� Function available on the tester ◗ Function available via partner application of the VAS 5053 ❍ Function not available.

Some of these functions can also be accessed in other operating modes via the Go to Destination Menu, see section 3.3.6.

Table 9-1 Functions in Administration

Funktionen VAS5051

VAS5051B

VAS5052

VAS5053

Install update � � � ◗

Net-update � � � ◗

Self-test � � � �

On first installation: Enter workshop code Afterwards:Change Dealership Identifier

� � � �

Signal Generator � � � �

Date/Time � � � �

Expanded Functions � � � ◗

Select Initial Graphic � � � �

Contents � � � �

Print Format � � � �

Print jobs ❍ ❍ ❍ �

Touch Screen Calibration � � � �◗

ESIS Installation or Update � � � ❍

Installation or update Assist ❍ � � ❍

Display user documentation � � � ◗

Activate telediagnosisAfterwards:Deactivate telediagnosis

� � � ❍

ELSA installation ❍ � � ❍

ELSA administration ❍ � � ❍

Application statistic � � � ❍

Installation applications � � � ❍

Dimension pressure / temperature � � � ❍

Page 166: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-2A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Network settings � � � �

Display network settings � � � �

Change CentralPartnerNet-password � � � ❍

Adjusting station name � � � �

Display target URL � � � �

Activating online connection via the Internet (Secure Client)

� � � ❍

Proxy settings � � � �

GeKo-test (confidentiality and component protection)

� � � �

Setting ISDN protocol � � � ❍

Installation of radio LAN � � � ❍

Online connection self-test � � � ❍

Importing importer settings � � � ◗

Application tests � � � �

Deactivating network update after restartAfterwards:Activating network update after restart

� � � ❍

Exporting function test files � � � ❍

Import function test files � � � ❍

System expansions ❍ � � ❍

Keyboard assignment ❍ � � ❍

Update installation ❍ ❍ ❍ �

Battery service ❍ � � �

Display battery charging ❍ � � ❍

Switching on erWin documentsAfterwards:Switching off erWin documents

❍ � � ❍

VAS 5053 ADMIN (partner application) ❍ � � ❍

Configuration of vehicle communication(for the present only on the VAS 5051B)

❍ � � �

Table 9-1 Functions in Administration

Funktionen VAS5051

VAS5051B

VAS5052

VAS5053

Page 167: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-3A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.2 Starting Administration

Administration is activated by pressing the button of the same name in the start mask.

Fig. 9-1 Starting administration (with installed applications)

Page 168: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-4A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.3 Selecting function

The "Administration" mask contains a list of all functions that can be activated in "Admin-istration" operating mode (also see table 9-1).

Fig. 9-2 Administration mask "Select function" (example VAS 5051B]

You can select the function you want by selecting the corresponding row. Then, another mask will generally be activated for that function, in which you can edit it and execute it. You can access further functions by moving the scroll bar downwards.

Page 169: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-5A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.4 Install update

You can use this function to install ➚base, ➚brand and ➚flash CDs. When installing, we distinguish between:

• InstallationInstallation of a complete version.

• Install updateUpdate of a version already loaded. An update is currently only applied for a base CD. An update base CD is equivalent to a fully updated base CD, however without Win-dows operating system. The hard drive is not formatted during installation. No data is lost. However, if a different language is loaded or if there is a new compatibility number, incompatible brand data cannot be displayed.

• IncrementAn increment (addition) is possible for all software installations (base, brand and flash CDs). Increments can only be loaded by means of a network update (see section 9.5).

When installing, you must check the language and compatibility between base and brand CDs. The version of the data of the base CD appears in the start mask, for example (fig. 2-1).

The version code can be deciphered by referring to fig. 9-3. It applies to all version IDs. The following conditions apply to the use of CDs:

1. The first version block corresponds to the compatibility number, which is defined by the base CD that was loaded. All brand CDs that you want to load on the tester must have the same compatibility number. The compatibility number is not evaluated for flash CDs.

2. Version block 2 indicates the continuative version of the software (base, brand and flash CDs). This block can vary between the base CD and CDs loaded thereafter.

Note on the base software installationWith every type of installation, the following data is placed in temporary storage and therefore retained:

− the workshop code, the dealership identifier, − the settings for the online connection of your tester.

With an update / increment base CD, the following is also retained:− brand CDs, loaded flash data, installed printers and the ELSA installation.

Saved jobs (see Interruption under section 6.12.1) need to be processed prior to a base installation. If necessary, reset your print format after installation of a base CD (see section 9.13).

Page 170: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-6A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3. Version block 3 shows "incremental" updates, which are continuously numbered and are loaded via network updates only (section 9.5). Incremental updates only consist of changes to a complete version.

Fig. 9-3 Deciphering the version code

9.4.1 Base CD

The complete base CD (in the following simply referred to as "base CD") is bootable and in addition to the complete Windows operating system contains the run-time systems for the individual operating modes. Once the base CD has been loaded you can use all operating modes apart from Guided Fault Finding and Guided functions. The use of the latter requires a loaded brand CD (see section 9.4.3).

Loaded brand CDs, user-installed printers and diagnosis jobs saved under Guide Fault Finding (see section 6.12.1.3) are lost.

NoteThe CD update/installation of a base CD will also start automatically if you insert the CD in the CD/DVD drive and switch the tester off and on. In this way, you can also carry out a CD update/installation if the tester has become inoperable, e.g. because the calibra-tion of the touch screen has been greatly offset. In the case of the VAS 5051B a calibra-tion run is started automatically when a base CD is loaded.

Version -GB- / V07.01.03 08/11/2004

Language code

Compatibility (block 1)

Current version (block 2)

Incremental update (block 3)

Version datum

Page 171: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-7A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.4.1.1 Loading a base CD

You can use the "Install update" function to load the contents of a newly supplied base CD onto the tester.

1. Insert the desired CD in the CD/DVD drive. To avoid read errors, the tester should not be tilted more than 15°.

2. In Administration select the "Install update" function.3. Confirm the security query regarding the update or installation of the inserted CD.4. The contents of the CD are now copied on to the hard drive. The tester must not be

turned off during this process. After the software has been loaded, the following mes-sage appears:

Remove the bootable CD-ROM and switch the power off and on to start the new system.

5. Remove the CD from the drive and restart the system. To do so, switch the tester off and back on again. The copied data is now being installed. As soon as the start-up is complete, the start mask will appear (see fig. 2-8) following confirmation of information regarding the station name and general safety instructions.

9.4.2 Update base CD

The update base CD is solely for updating program components which form part of the base CD.

9.4.2.1 Loading an update base CD

An update base CD is loaded in the same way as the installation of a complete base CD but with these differences:

• There is no message as mentioned under section 9.4.1.1, 4 and no restart. It suffices to remove the CD once installation has finished.

• You cannot install the update base CD by switching the tester off and back on again.

Page 172: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-8A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.4.3 Brand CD

You can install new or additional brand CDs on the tester.

1. Insert the desired brand CD in the CD/DVD drive. To avoid read errors, the tester should not be tilted more than 15°.

2. In Administration select the "Install update" function.3. Confirm the security query regarding the installation of the inserted brand CD.4. The contents of the brand CD are now installed on the tester. As soon as the nstalla-

tion is complete, the tester switches from Administration operating mode back to the start mask (see fig. 9-1).

5. Remove the CD from the drive.Install additional brand CDs if necessary by repeating steps 1 through 5.

9.4.4 Flash CD

A flash CD is installed in exactly the same way as a brand CD.

NoteYou can only ever load brand CDs whose compatibility number and language match the base CD; refer here to the description supplied with the CD.

When a brand CD is installed, saved diagnosis jobs of the relevant brand are lost (see section 6.12.1). For this reason you should first complete any jobs that may have been saved.

Several brand CDs for different brands can be installed on the tester (VW, Audi, and so on).

When a new brand CD is installed, it overwrites any previous installation of the same brand.

NoteIf the flash CD cannot be installed, the data for update programming of the control unit are loaded directly from the CD inserted in the drive. Please refer to the description accompanying the CD to find out what kind of flash CD it is.

Page 173: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-9A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.5 Net-update

When this menu item is carried out, the tester searches via the active LAN connection for a software update under the relevant URL address "➚Mirror server" (see section 9.25.4). This can be data otherwise located on a base, brand or flash CD.

Automatic network update on startup

If a LAN connection exists, updates are searched for each time the tester is switched on and started up. If updates are found, a query appears asking whether you want to install the data. The tester should therefore be connected to the LAN network once each day when it is switched on. If the tester is not regularly connected to the LAN network, you should start the "Net-update" function manually.

You can use the "Net-update/Deactivating network update after restart" function to deac-tivate this automatic search for updates, if desired (see section 9.25.13).

Network update run sequence

If you select the "Net-update" function, the tester attempts to connect via its LAN connection to the local dealership mirror server.

If it is not possible to set up a connection, the following fault report appears:

The contacted HTTP server could not befound.Please check the connection infrastructureand the login URL (Administration)

If the tester is able to establish the connection, it will compare the version levels (of base, brand and flash data). If an update is found, a dialog box appears with a query as to whether this update should be installed. If not, a message is displayed, informing you that no new updates are available.

The data from the mirror server are initially stored temporarily on the tester and are then installed. When the base CD is updated, a message will appear telling you that the tester must be restarted.

If the network connection is interrupted during communication, the tester will attempt to restore the connection. If this does not succeed, a question will appear asking whether further attempts should be made to establish the connection, or whether communication should be cancelled.

Page 174: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-10A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Base system

The base system can be replaced completely up to the Windows operating system via a network update, or can be replaced in part. Complete replacement with the Windows system can only be done by installing a CD.

Network updates for the base system will not delete any brand and flash data that have been loaded. They will remain available after the update.

Brand data

An update can make changes here up to and including complete replacement of all data. A brand can only be updated on the tester if it is already there on the tester (it must have been installed at least once previously from a CD).

Flash data

During an update, the tester is informed of the flash data present on the mirror server with-out them being loaded. Any flash data required will only be loaded onto the tester when needed, via online connection.

Page 175: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-11A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.6 Self-test

Select the Self-test function in Administration to start an integrated self-test of the test Instruments (VAS 5051 only) or of the diagnostic bus. In doing so, you test the diagnostic vehicle connection in the tester, including the diagnostic cable and the internal test instruments unit.

The result will be output on the screen in the form of a "OK/not OK display" (see fig. 9-4).

If "not OK" and a fault number are specified following a test, please consult the service centre responsible for your region (see /3/).

Fig. 9-4 "Self-test" mask

NoteThe self-test of the Test Instruments does not cover the connected measuring leads. How to test these manually is described in /3/, chapter "Troubleshooting.

Page 176: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-12A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.6.1 Test Instruments unit (VAS 5051 / VAS 5051B only)

1. To carry out a self-test of the test Instruments, select the "Test Instruments unit" line in the function list. The following request appears on the VAS 5051:

Disconnect all measuring leads from tester.

2. Confirm with "OK" when you have disconnected all the measuring leads that were connected on the tester.

3. The self-test that will now be performed will take one to several minutes. No entries can be made during this time. The results of the self-test are displayed in the right-hand section of the work window.

4. Reconnect all the measuring leads required back on the tester.

9.6.2 Diagnostic bus unit

While the self-test is running, follow the instructions that appear on the screen regarding the removal and connection of the diagnostic cable, test adapter (VAS 5052/4) or test adapter cable (VAS 5051B/4, can also be used on the VAS 5053). After a few more sec-onds, the results of the self-test are displayed in the right-hand section of the work win-dow.

VAS 5051 run sequence:

1. To carry out a self-test of the diagnostic bus, select the "Diagnostic bus unit" line in the function list. The following request appears:

Disconnect diagnostic cable from tester.

2. Confirm with "OK" when you have disconnected the diagnostic cable that was con-nected on the tester.

NoteThis request appears even if no measuring leads are connected to the tester. In this case, simply confirm with "OK".

NoteThis request appears even if no diagnostic cable is connected to the tester. In this case, simply confirm with "OK".

Page 177: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-13A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

3. After a few seconds, the following request appears:Cable short circuit testConnect diagnostic cable to tester(not connected to vehicle)Caution:The diagnostic cable LT (VAS 5051/4)must not be connected.

4. Connect a diagnostic cable to the tester; do not connect the other end to the vehicle.5. After a few more seconds, the results of the self-test are displayed in the right-hand

section of the work window.

VAS 5052 run sequence:

The self-test of the diagnostic bus runs through three phases:

1. Test of the diagnostic bus with diagnostic cable not connected.2. Test for short circuit with diagnostic cable plugged in and one end not connected (with-

out test adapter).3. Test for line interruption with diagnostic cable connected and test adapter plugged in.

VAS 5051B / VAS 5053 run sequence:

1. A message will appear telling you to connect the diagnostic cable to the tester and to connect the test adapter cable to the diagnostic cable and to the vehicle. Terminal 30 is required on the vehicle's OBD plug. The vehicle type is irrelevant.

2. The self-test will complete without any further messages. The result is displayed in the exit mask. The self-test may take up to 3 minutes.

NoteThe self-test only detects short circuits in the diagnostic cable. More thorough-going self-tests of the diagnostic cable are not available.

Page 178: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-14A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.7 Enter Workshop Code/Change Dealership Identifier

Enter Workshop Code

If you activate the Enter Workshop Code function from the function list in the Administra-tion mask when the tester is started up for the first time, you can enter your VZ/importer number, your dealership number and then your dealership identifier. For further informa-tion on initial startup of a new – or replaced – tester, refer to chapter 2.

Changing the dealership identifier

After you confirm your entry of the importer number and dealership number, this data is barred. When you next activate Administration, the Enter Workshop Code function will be replaced by "Change Dealership Identifier". This allows only the dealership identifier to be changed, permitting you to enter the name and address of your workshop.

Page 179: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-15A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.8 Signal Generator

When certain events occur, e.g. incorrect entries on a virtual keyboard, the tester emits an acoustic signal. You can adjust the duration and pitch of this signal in the "Signal gen-erator" function. The setting has no effect on the "Battery loading too low" alarm.

Select "Signal generator" in the function list to display the following mask:

Fig. 9-5 "Signal Generator" mask

You can use the two slide controls to modify the acoustic signal (see section 3.3.7 for operating instructions). The numeric values above them indicate the currently set values.

• You can modify the time the signal lasts using the upper slide control, marked "Dura-tion". The setting is continuously adjustable between 0 (furthest setting on the left) and 3000 ms (furthest setting on the right).

• The lower slide control, marked "Pitch", controls the frequency of the signal. The setting is continuously adjustable between 0 (furthest setting on the left) and 4000 Hz (furthest setting on the right).

When you move a slide control, the tester generates a signal with the last pitch and dura-tion set. A low setting is recommended, e.g. a duration of 300 ms and a pitch of 1000 Hz. The volume of the signal cannot be adjusted.

Page 180: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-16A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.9 Date/Time

Select the Date/Time function in Administration to adapt the system's date and time to the correct values. The setting options are described in section 2.3.

9.10 Expanded Functions

This allows other functions on the tester to be enabled for service/repair purposes and de-velopment purposes. It is only available with the use of special key CDs, which are not included in the tester package.

9.11 Select Initial Graphic

Select the Select Initial Graphic function in Administration to set which graphic you want to appear in the start mask of the tester. You can select a different graphic via the Continue button. The selected graphic is shown as soon as you switch over to the start mask by pressing the Back button.

9.12 Contents

If you select the "Contents list" function in the function list, the installed base and brand CDs will be displayed for selection in a new mask, along with their version information. Select a CD to view more information about it. Its contents file will then be shown.

Information will be displayed on the software loaded: modifications, new features, con-tents.

The contents list thus displayed can also be output via the "Contents list" function in the print menu.

Page 181: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-17A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.13 Print Format

If you select the Print Format function, you will be shown a new mask where you can spec-ify a printer driver with the corresponding paper format and also the print mode. The cur-rent setting is shown by the position of the selection bar.

9.13.1 Printer driver / Paper format

VAS 5051, VAS 5053:

For the VAS 5051, the OKI printer driver is preinstalled with ➚IrDA interface and with ➚USB interface for the VAS 5053. Check or change the paper format setting by select-ing "DIN A4" or "US Letter".

VAS 5051B, VAS 5052:

By default, various Printer drivers with the corresponding interface (IrDA or USB) for paper formats DIN A4 and US Letter are preinstalled. Change the default setting by selecting an option.

Other printers can be installed via the "System expansions" function (see section 9.28). For printers you have installed yourself you can specify printer properties yourself (see section 9.13.3).

Fig. 9-6 "Print Format" mask

Page 182: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-18A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.13.2 Print type

With the "White background (save mode)" print mode, printing takes place in black and white only, which means the printer uses less toner or ink.

Load the selected printer with paper corresponding to the format. The new setting will be adopted with the next print command sent. It is retained until the next update installation of the base CD.

9.13.3 Changing printer properties

Only for printer drivers you have installed yourself can you change the printer properties (see section 9.28). Select the printer in question and click on the printer symbol which appears to the right of the selection line. In the dialogs which appear you can now make the settings in accordance with the Windows 2000 standard.

Fig. 9-7 "Print Format" mask: changing printer properties

Page 183: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-19A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.14 Print jobs (VAS 5053)

The VAS 5053 can print data on a USB printer that is connected to the docking station with a USB cable or to the tester via the multifunction adapter. If no printer can be accessed via USB during the printing process, the tester is able to save the data tempo-rarily as files. To do this, select the function "Save to VAS 5053" in the "Print/Save" dialog box that appears. The current print job is saved and added to the list of print jobs.

The "Print jobs" function allows you to view the list of print jobs currently saved, together with their date and time. Select one or more of the print jobs displayed and press the "Print" button. Select the "Print highlighted file(s)" function in the menu that appears.

The following message appears:

Was(were) the file(s) successfully printed?Repeat Cancel OK

Select "OK" if printing was successful. The corresponding print jobs are deleted.

You can use the "Print/Print all files" selection to print all saved print jobs together.

Print jobs are deleted from the VAS 5053 once a specified volume of data or age is exceeded. If this happens, a message will appear.

NoteProtocols containing more than 38 pages are displayed in red on the VAS 5053 and can only be printed via the external storage device or the partner application (also see /4/).Saved print jobs can only be output on the printer and not to the external storage device any more.The partner application is used mainly for output of larger logs which can no longer be printed out on a printer directly connected to a VAS 5053. Screen printouts and other print jobs cannot be output using the partner application.

Page 184: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-20A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.15 Touch Screen Calibration

Select the Touch Screen Calibration function in Administration to calibrate the touch screen. This might be necessary if the cursor does not follow your touch pen or finger exactly on the screen.

First, a prompt appears (not on the VAS 5053) asking whether you really want to cali-brate the screen. Confirm with "OK". Now the following messages will appear:

VAS 5051 run sequence:

This function is only accessible on initial startup or after reinstalling the base CD, and is removed from the selection list after that. Therefore proceed with caution.

The following message will appear first:

Touch the targets from a position of normal use.

A calibration circle will now appear at top left. Touch it as precisely as possible. Repeat the procedure at the other positions. The calibration will then be checked. The following message will appear accordingly:

Touch different areas on the screen. Does the cursor jump to your fingertip?

Now touch the screen in different places and check the position of the pointer. Select "No" to repeat the calibration or "Yes" to accept it. Calibration is ended when a setting is accepted.

VAS 5051B / VAS 5052 run sequence:

Calibration of the touch screen is always accessible.

The following message will appear first:

Touch the calibration target to start the calibration.

Caution!Exercise great care when adjusting this function. Incorrect or improper usage may cause the touch screen to be put irrevocably out of alignment and thus become inoper-able.Tap the indicated touch targets once, quickly and lightly. Tapping a target inadvertently more than once will actually input for the next touch target which should be somewhere entirely different: the result will be that the touch screen will be very poorly calibrated.

If this happens, re-install the base CD (section 9.4.1).

Page 185: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-21A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

When you see this message, touch the calibration circle on the screen to start the proc-ess. A series of circles marked with four arrows will then appear on the screen with a red dot at the centre of each. Touch each dot as precisely as possible until the tester shows the following message:

Touch the screen to see if the cursor jumps to your finger. Press No to calibrate again or Yes to accept the calibration.

Now touch the screen in different places and check the position of the pointer. Select "No" to repeat the calibration or "Yes" to accept it. Calibration is ended when a setting is accepted.

VAS 5053 run sequence:

The following message will appear first:

Touch the calibration target to start the 7-point 1) calibration.

When you see this message, touch the calibration circle on the screen to start the pro-cess. A series of circles marked with four arrows will then appear on the screen with a red dot at the centre of each. Touch each point as precisely as possible.

If calibration has been started and no input occurs for 15 seconds, you will be taken back automatically to the mask you started from.

1. Depending on the touch calibration last carried out, 7- or 20-point calibration.

NoteThis screen calibration can also be started via the partner application. That might be essential if the touch screen is put irrevocably out of alignment and thus becomes inop-erable.

Page 186: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-22A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.16 ESIS Installation or Update

You can use this function to install the "Electronic Service Information System" (USA only). Afterwards, you can activate ESIS via the Applications operating mode (see chapter 8). An ESIS CD must always be inserted in the CD drive when running the ESIS functions. The ESIS CD set is not included in the general tester package.

9.17 Installation or update assist (not VAS 5051)

You can use this function to install a Bentley Assist CD.

After Bentley Assist has been installed, a new button will appear in the start mask with which you can start this application. You can also access it from the tester operating modes via the Go to button. Launching Bentley Assist does not require the CD to be inserted.

The program is operated via the virtual keyboard as described in section 3.3.8.5 or via a connected USB keyboard.

The Bentley Assist CD set is not included in the current package.

Page 187: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-23A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.18 Display user documentation

When you select this function, the following mask appears. The different documentation versions are available here. The size of the list displayed may vary. If you select a line, the corresponding document is displayed as PDF file.

The mask in which the document is displayed and its operation differs according to the tester. The following sections contain more information.

Figura 9-8 Selecting the user documentation

Page 188: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-24A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.18.1 Displaying a document on the VAS 5051

The operating manual will be displayed when you select this function. The base CD must be inserted for this.

Fig. 9-9 A document displayed on the VAS 5051, example: "Operating Manual Hardware"

The mask consists of a large display window (including operating bars) and the navigation bar. The additional buttons in the navigation bar have the following functions:

9.18.1.1 Zoom

• Pressed: zoom function switched on, offset function switched off.When you press "Zoom", the pointer will take the form of a magnifying glass. You can now tap any point on the displayed page of the document. The display will now be zoomed in to the next level of magnification higher, and the point tapped will be moved to the centre of the display window.If you tap any point on the displayed page and keep your finger on it, you can also open up a frame for enlargement by moving the pointer diagonally with your finger ("rubber band" function). When you lift your finger, the framed section of the page will be enlarged to the full width of the display window.

• Not pressed: zoom function switched off, offset function switched on.When you disable the Zoom button and tap on the page indicated, the pointer will take the form of a hand.

You can now move the displayed page in any direction, for as long as the Zoom button is inactive. Touch the screen in the area of the displayed document and move your finger.

Page 189: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-25A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.18.1.2 Original size

When you press this button, the displayed page will be zoomed in or out to its original size (100 %). This will occur regardless of the status of the Zoom button.

9.18.1.3 Backward

You can use this button to undo actions that you have performed in the display of the op-erating manual, e.g. zoom the displayed page back out again or return to a previously dis-played page. You can undo actions in sequence, with one undone every time the Backward button is pressed. The sequence of the actions is independent of the status of the Zoom button.

9.18.1.4 Forward

This button is the counterpart of the Backward button. You can use it to redo actions that you have undone. The Forward button has no function if you have gone back to the last action performed.

9.18.1.5 Print

To print individual pages from the tester's manual, select "Print, Document" and enter the desired page range. To enter a page number, select the page display button and enter the number using the numeric keyboard which appears. You can use the adjacent arrow keys to increase or decrease the page number incrementally. It cannot be written to a external storage device.

Page 190: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-26A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.18.1.6 Operating bar

The display window contains a vertical operating bar and a horizontal operating bar, which you can use to carry out the following functions:

• Zoom the display in or out to a defined percentage value. Adjust the displayed page to the size of the window ("Fit in Window" option), the width of the window ("Fit Width") or its original size (100 % or "Actual Size").

• Display of the current zoom factor (percentage value).• Jump to the start or the end of the document.• Page through the text forwards or backwards.• Display of the current page number and the total number of pages.• Display of the page width and height.• Offset the displayed page horizontally, to the right or the left.• Offset the document vertically up or down, by line or by page. When you move beyond

the edge of the displayed page, the next or previous page will be loaded and shown.• For Western European languages only:

− Switch an additional window on and off for bookmarks and thumbnail views of the individual pages of the operating manual.

− Offset the display in this additional window horizontally and vertically using scroll-bars.

− Select bookmarks. They correspond to the operating manual's list of contents, so you can simply click on a row in the bookmarks window to load the desired section and show it in the display window. The small plus and minus symbols to the left of a bookmark indicate the presence of index levels nested inside the current one. Se-lect a plus symbol using a pen to show the next bookmark level lower.

− Select thumbnails: no function.− Select articles: no function.

You can also navigate from one page to another in the document itself. If, for example, you find a cross-reference in the text to a different chapter, an image or a table, you can select it. The page to which the cross-reference relates will appear in the display window as soon as you lift your finger from the screen.

In the same way, you can also reach a topic directly by selecting the relevant line in the list of contents or in the index. This function also gives you quick access to topics required if the additional window for bookmarks and thumbnails is not available.

You can generate a screenshot or print the entire document via the Print button in the nav-igation bar. This function also gives you fast access to topics required if the additional win-dow for bookmarks and thumbnails is not available.

Page 191: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-27A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.18.2 Displaying a document on the VAS 5052, VAS 5051B,(VAS 5053)

On the VAS 5052, VAS 5051B and in the partner application for the VAS 5053 the oper-ating manual is displayed with a higher Adobe Acrobat Reader version. Operation is sim-ilar to that in section 9.18.1 with the difference that the "Zoom", "Original size", "Forward" and "Backward" buttons are available in a different form (see /1/).

Fig. 9-10 A document displayed on the VAS 5052, example: "Operating Manual Software"

9.18.3 Viewing and printing user documentation on a PC

You can find information for displaying and printing documents on a PC in /1/.The documents are on the base CD in the "MANUALS" directory.

Page 192: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-28A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.19 Activate/deactivate telediagnosis

This function allows remote access to the tester via a network.

The IP address assigned is displayed when telediagnosis is activated (see fig. 9-11). See section 9.25 for information on the network settings.

Two procedures are available for telediagnostics:

• Telediagnostics (waiting)• Telediagnostics (RSIS (Remote Service Information System)). Here you can select

your supervisor directly."Telediagnostics (passively waiting)" is preset by default. The "Telediagnostics (RSIS)" selection can only be selected if it was enable on your tester.

9.19.1 Telediagnostics (waiting)

This procedure is installed on all testers as standard.

When telediagnosis has been activated, an expert such as a product manager can set up a connection to your tester. From his desk that expert can now view the same screen as you are currently seeing on your tester and follow diagnosis being carried out on a vehicle or remotely control the tester. Communication on the same line via LAN is only possible with the VAS 5051B and the VAS 5052 when a suitable headset is used, pro-vided the person at the other end of the line is similarly equipped. If not, communication will have to be by phone.

NoteYou can connect the VAS 5051 via LAN or ISDN. This requires either the optional ➚Eth-ernet package VAS 5051/45 or the optional ISDN package VAS 5051/38.VAS 5051B and VAS 5052 have an Ethernet interface included as standard. You can also install the optional ISDN package VAS 5051/38.

Page 193: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-29A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Activate telediagnosis as follows:

1. Connect the tester to your local network (LAN) or to a terminal connection on your ISDN system.

2. Select the "Activate telediagnosis" function. It will not be activated automatically after switching the tester on. When you activate telediagnosis, a note with the current sta-tion name and the tester's IP address will be displayed. The option in the selection list will switch to "Deactivate telediagnosis".

3. Call the expert. If your tester is connected to an ISDN system, tell the expert the ISDN phone number that is assigned to the terminal connection internally within your com-pany. If your tester is connected to your local LAN, the expert must have previously discussed with your system administrator the procedure for dialling into your local net-work. The necessary access authorizations have been given, the station name and IP address are known or will be provided by yourself. The expert is now able to set up a connection to your tester.

4. The expert starts its program at its expert workstation. Then a query appears asking you to accept or reject the link (see fig. 9-12). Select "Accept".

5. Now the expert sees the same mask that your tester is showing and can send control commands from there. You can see that telediagnosis is active from the remotely con-trolled movements of the pointer or from the fact that your tester does not react to op-erating functions (if the expert has set this option).

6. Via telephone, you discuss further steps to take for operating the tester and the appli-cation.

7. When telediagnosis is finished, end the connection by selecting the "Deactivate tele-diagnosis" function.

NoteDo not deactivate telediagnosis during ongoing communication, since fault reports will otherwise be received.

NoteYou yourself cannot set up a connection independently from the tester to the expert workstation.

Page 194: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-30A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Fig. 9-11 "Activate telediagnosis" mask: (example: VAS 5051B)

Fig. 9-12 Telediagnostics, confirmation of the link (the other end of the line displayed may vary)

Page 195: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-31A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.19.2 Telediagnosis (RSIS)

This function will only be available when the necessary data has been installed on the tester via your importer. Only in this case will the mask shown below appear.

Fig. 9-13 "Telediagnostics" dialog: Select type of telediagnosis

• Select the procedure you wish to use, here "Telediagnostics (RSIS)".• Press "OK". The tester now presents a selection list of experts. You can make your

choice (fig. 9-14) and actively set up a connection to the expert to carry out a teledi-agnosis. Communication on the same line is possible with the VAS 5051B and the VAS 5052. For this a headset is used at the tester and at the other end of the line.

• In Administration the line "Activate telediagnosis" changes to "Deactivate telediagno-sis".

• Cancel button: Telediagnosis will be aborted.• If the expert confirms the selection, your tester displays a query appears asking you

to accept or reject the link (see fig. 9-15). Select "Accept".

Page 196: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-32A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Fig. 9-14 "Telediagnostics" dialog: selecting a supervisor

Fig. 9-15 Telediagnostics, confirmation of the link (the other end of the line displayed may vary)

Page 197: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-33A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.20 ELSA installation

You can use this function to install the run-time system for the "Elektronische Service-Auskunftssystem" (electronic service information system) or carry out an update. Insert the ELSA installation CD and start the "ELSA installation" function.

The tester supports the operation of ELSA version 3.0 and later with the operating modes:

• Client-server mode - ELSA data written to a workshop server• Stand-alone mode - ELSA data written to the testerThe ELSA installation initially only installs ELSA's run-time system on the tester. After this you will need to load the ELSA data onto your server or tester, depending on the operating mode you want. In the latter case, insert the corresponding DVD or CD no. 1 into your tester drive and select "ELSA installation" again. If you are using ELSA data via a server, the tester must be connected via a LAN cable to your workshop network.

For further information on using ELSA and "ELSA administration", please refer to the documentation for ELSA.

After ELSA has been installed, the ELSA Win button will appear in the start mask and can be used to start this application. You can also access it from the tester operating modes via the Go to button. The "ELSA administration" function also appears in the Administration.

The program is operated via the virtual keyboard as described in section 3.3.8.5 or via a connected USB keyboard.

9.21 ELSA administration

This function calls the ELSA administration service and you will be asked to log in. In ad-ministration you can, for example, set up a new user.

Caution!Do not confuse the "ELSA Installation" function with the "ESIS Installation or Update" function! If you activate the wrong function after inserting an ELSA CD, you will no longer be able to operate the tester and it may have to be restarted.

NoteThe "ELSA Win" application is retained even after installation of a base CD.

Page 198: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-34A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.22 Application statistic

You can use this function to display statistics indicating how often you have activated the individual operating modes or installed applications (e.g. ELSA, ➚erWin, Bentley Assist) and how long you have used them for. The "Lingering time" adds the periods of time between the activation of an operating mode at the start mask and deactivating it by returning to the start mask. The "OBD" operating mode is incorporated under the "Vehi-cle self-diagnosis" operating mode.

Fig. 9-16 Application statistic (here VAS 5051B)

Delete

The application statistics begin to count after a base CD is installed. The Delete button, however, manually resets the specified frequencies and times to zero.

Print

You can use the "Print" function to print out a protocol of the application statistics.

Page 199: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-35A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.23 Installation applications

You can use this function to install external applications. An appropriate installation CD must have first been installed in the tester's CD/DVD drive.

There are two types of applications, started in different ways:

• Applications that are entered under the Applications operating mode after installation, and which can be started from there (see chapter 8).

• Applications for which an extra button is added to the start mask after installation, which you can use to start them, e.g. the partner application VAS 5053 (see section 9.34). You can install up to five applications on the tester in this way.

Applications with their own start button

An application that has a start button can only be started in the start mask or the Go to Destination menu and runs independently on the tester (does not apply to the partner application). After exiting the application, the tester returns to the initial mask from which the application was started.

An operating bar may be displayed to operate the application (see section 3.3.8.5). It can also be used to go back to the tester software.

9.24 Dimension pressure / temperature

In the independent Test Instruments (see section 5.3.8 and section 5.3.9), you use this function to set the units used in your country for pressure (bar or lb/in2) and temperature measurement (°C or °F).

Table 9-2 Installation and activation of applications

Application Installation via administration Button in start mask

Bentley Assist Installation or update assist (section 9.17)

Bentley Assist

ELSA ELSA installation (section 9.20) Elsa Win

erWin Switching on erWin documents (section 9.33)

erWin

ESIS Installation or update of ESIS (section 9.16)

(Activation only via "Appli-cations" operating mode)

Partner application Installation of applications VAS 5053 ADMIN

Page 200: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-36A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.25 Network settings

The following mask will appear when you select "Network settings" in the Administration mask (see fig. 9-2).

Fig. 9-17 Network settings

Setting the IP address

The tester is set so that it will automatically adopt an address from a ➚DHCP server in the workshop network. A manual input is not possible. If there is a connection, you can use "Display network settings" to have the assigned IP address displayed (see section 9.25.1).

NoteThe functions described in the following are used for connecting the tester online to the VW database server and enable the exchange of data with that server. Normally online operation takes place via the workshop network that is enabled for the database server. Independent workshops need to activate the secure client for this purpose (see section 9.25.5) and enter an appropriate login with password prior to connection setup.

Page 201: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-37A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.25.1 Display network settings

When you select this function all network settings will be listed. The information is de-signed for a network administrator. The settings can be printed by pressing the "Print" but-ton and selecting the "Network settings" menu item.

9.25.2 Change CentralPartnerNet-password

The password cannot be changed directly on the tester. The following message will appear:

Please change the password centrally in ACC (dealership system user administra-tion), or ask your administrator to change it.

9.25.3 Adjustusting station name

To connect the tester to the local workshop network, it will require a unique station name. In the factory all testers are given the station name "VAS505x" (x=1, 1B, 2 or 3). It is absolutely essential to change this station name. Every time the tester is started and each time you switch to the start mask you will be reminded of this by the following mes-sage:

"VAK0200WNo network communication is possible with the current station name.

Please change the station name viathe menu item Administration / Network settings"

As long as you leave the factory-set station name unchanged you will not be able to use the following functions which need the network connection:

• Automatic network update on tester start-up• Administration / Network update• Administration / Activate telediagnosis• Administration / Network settings / GeKo test• Administration / Network settings / On-line connection• ELSA client version• Test program instruction with network access• Sending online protocols in the Guide Fault Finding application• Sending temporarily stored on-line logs at start-up

Page 202: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-38A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

• Installation of network printer drivers under Adminstration / System expansions• Selection of a network printer under Administration / Print format• Online flash dataIf a network connection can be set up, the "Adjust station name" function displays a rec-ommendation for the new station name:

<first 8 positions of the DNS domain>O<5 characters for tester number>

The following table explains the significance of the individual parts of the name.

Use the virtual keyboard to change the recommended station name, if required. You must at least change the tester number. The station names must be unique for all the testers used.

If the factory-set station name has already been changed, the function will show the changed station name. You can accept the setting or change it.

If you enter a new station name, the following message will appear:

System must be switched off and restarted.

Confirm with "OK". The tester restarts.

You can also select the "Display network settings" function to view the station name cur-rently set and the tester's IP address (see section 9.25.1).

9.25.4 Displaying target-URL

In the "Display target-URL" mask you can choose between "General URLs" and (with the brand CD installed) "Brand-specific URLs". The ➚URL addresses available for selection are displayed. These addresses are permanently set by the loaded base and brand CDs and cannot be changed later at the tester.

Table 9-3 Diphering the station name

Character Section Comment

1-8 ➚DNS domain Is automatically assigned when connection set up.

9 Separator Capital O, not a zero!

10-14 Tester number Default setting is "00010".

Page 203: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-39A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.25.5 Activate/Deactivate online connection via the Internet (Secure Client)

You can use this function to manage the access rights for the VW database server. The activation of the secure client can remain switched on permanently, regardless of a con-nection that actually exists.

Once the "Activate online connection via the Internet (Secure Client)" function has been successfully activated, it switches to "Deactivate online connection via the Internet (Secure Client)".

9.25.6 Proxy settings

Online access to the VW database server can be streamlined via proxy servers. You must enter the relevant proxy server address that is to be used for online connection. You can use a virtual keyboard to enter proxy addresses with up to 80 characters. If there is no entry no proxy is used for addressing.

The following address entries are available:

• HTTP proxyfor entering a normal proxy address.

• HTTPS proxyfor entering an address for secure data transmission. Data will be encrypted for trans-mission.

Select the corresponding characters for entering an address either in the form <url>:<port> or as an IP address. You can enter the URL address as IP address or as alias name. Press the "Back" button or the "Q" button to accept the proxy addresses entered.

Enter the address required e.g. the one stipulated by your IS administrator. Both address entries can exist simultaneously, apart from with the VAS 5053.

The proxy entry is retained even when a base CD is installed.

NoteThis function is only required in independent workshops, since they use the tester via the Internet, i.e. without VW workshop network.Do not switch it on if your tester is connected to the normal VW workshop network, since the online connection would no longer work in such a case.

Page 204: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-40A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.25.7 GeKo-test (confidentiality and component protection)

The GeKo-test checks the transmission of data for the Audi brand from the tester to the company database and back, including user ID verification. The test represents a more thorough-going test than the "Online connection self-test". The self-test essentially checks the online connection only, albeit with any destination address you choose.

The GeKo-test requires the user ID issued for authorised persons and the password. An Audi brand CD must be installed for the test, but a vehicle connection is not required.

9.25.8 Setting ISDN protocol

You can use this function to set a country-specific ISDN protocol for telediagnosis. The protocol shown with inverted lettering corresponds to the current setting. A new selection is accepted with Back.

Fig. 9-18 Setting ISDN protocol (VAS 5051)

NoteWith the VAS 5053, only one proxy address can be entered for an HTTP or an HTTPS proxy. The address is always entered under "HTTP proxy".

Page 205: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-41A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Fig. 9-19 Setting ISDN protocol (VAS 505, VAS 5051B)

9.25.9 Installation radio LAN

After this menu item is executed, software installation of a radio LAN card begins from the VW CD.

9.25.10 Online-connection

Before carrying out a self-test of the online connection, ensure that the tester is con-nected to the workshop network and thus has access to the VW database server.

If you select the "Online connection self-test" line, a prompt will then be displayed asking you to select a URL address. Select the destination address via which an online connec-tion is to be set up and tested, e.g. "LogonUrl", "Mirror-Server".

If the connection could not be established, a note will appear to that effect, e.g.:

Mirror server self-test online connection not OK.

You can view further details via a log file. The detailed information is designed for an ad-ministrator.

Page 206: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-42A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.25.11 Importing importer settings

In different markets, different settings are sometimes necessary within networks regard-ing security aspects, destination addresses (URLs) in networks and also for telediagnos-tic procedures. These settings are provided on what is referred to as an "importer CD" for the market in question.

You can use this function to load the data from an inserted importer CD on to the tester.

9.25.12 Application tests

You can use these to activate specially stored function tests via brand data. You test net-work access including user application, like e.g. for the GeKo-test (see section 9.25.7).

Prior to the application test, make sure that the tester is connected to the workshop net-work and thus has access to the VW database server.

If you select the "Application test" line, a general message appears first, prompting you to select an installed vehicle brand. If tests are available for the selected brand, these are displayed to you in a separate selection mask. If necessary, enter the login and password for your online connection. The application test expires and ends with a success or failure message.

9.25.13 Activating/deactivating network update after restart

This function switches off the automatic activation of the "Network update" function on starting the tester (see section 9.5). If you select it, your display changes to: "Activating network update after restart". On selecting this function you can resume the automatic search for network updates, if necessary.

Page 207: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-43A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.26 Exporting function test files

You can use this function to export to a removable storage device those files which have been stored on the tester's hard drive by a function test.

The tester presents a list of all relevant files for selection. Choose the desired data and press "Continue" to write them to the removable storage device. Non-exported files more than 60 days old are deleted from the tester.

9.27 Import function test files

You can use this function to import files of type "*.tpr" onto the tester from a removable storage device. The data is stored on the tester's hard drive. A function test that requires these files can then access them.

Page 208: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-44A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.28 System expansions

With this function you can make specified system expansions, such as "Add printer".

9.28.1 Add printer

Example of installing a USB printer

This is how to install your own USB printer with the help of the wizard:

1. Connect the printer with a USB cable. Switch the printer on.2. Restart the tester. When it starts it will detect the new printer and assign it a USB port.3. Select the "Add printer" function.4. In the "Welcome to the Add Printer wizard" mask press the Next button.5. In the next mask, "Local or network printer" select the "Local printer" option and con-

firm with the Next button.6. In the next mask, "Select the printer port", select the new port "USB..." (for which no

printer has yet been assigned) and confirm with the Next button.7. In the next mask, "Add printer wizard" select the printer to be installed and confirm with

the Next button.If the printer is not standardly supported by Windows, click on the Have disk button. In the next dialogs you can then open information files with the extension "*.inf" on a diskette, CD or DVD and load the corresponding printer driver.

NoteA user-specific printer driver is installed with the usual Windows 2000 procedure. It should only be carried out by an IT adviser. To protect the data, the right-hand mouse button is disabled during the installation procedure.You can open files on third-party data media which have the extension "*.inf". You will not be able to load printer drivers which are to be installed by an "*.exe" file.

USB printers or LAN printers on the workshop network can be installed.

A virtual keyboard as described in section 3.3.8.5 appears in order for the required input to be entered for installation.

Page 209: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-45A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

8. In the "Name your printer" mask confirm the preset printer name by pressing the Next button.

9. In the next mask, "Printer sharing", select the "Do not share this printer" option and confirm with the Next button.

10. Select whether you want to print a test page ("Yes" or "No") in the "Print Test Page" mask.

11. In the last mask, "Completing the add printer wizard", finish the installation and click on the Finish button.

The printer driver has now been installed and is given the name ending of "_usr". You can select it in Administration under "Print format" (see section 9.13). In addition, on the right of the selection a printer symbol will appear. With this you can also set the print properties of the newly installed printer (see section 9.13.3).

9.29 Keyboard assignment

With this function you can change the keyboard assignment of the virtual keyboard for applications / installations (see section 3.3.8.5) to suit certain languages. It is used, for example, for ELSA functions and printer installation.

The keyboard assignment set will also apply to a USB keyboard connected to the VAS 5051B or VAS 5052.

9.30 Update installation (only VAS 5053)

You can use this function to specify the reaction of the VAS 5053 during the CD update and network update via the partner application (see section 9.4, section 9.5 and section 9.34). On making a selection, the display switches between three self-explana-tory settings:

• Install all updates without inquiry• Only install online updates without inquiry• Confirm every update individuallyIf you select the last option, the VAS 5053 displays a query prior to the actual installation asking you whether the update displayed is to be applied.

Page 210: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-46A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.31 Battery service

Battery service is offered for all testers, except the VAS 5051, and should be performed at specific intervals to maintain the battery's capacity and to adapt it to the charging cir-cuit (also see /3/). During battery service, the integrated battery is discharged to a large extent (but no total discharge!) and can then be recharged again without delay. Depend-ing on the current state of charge, this may take a few hours; the tester cannot be oper-ated during this time. That is why it is ideal to perform battery service at night or during a long stationary phase. In urgent cases, you can switch the tester off and back on again during battery service to cancel it.

VAS 5051B and VAS 5053 sequence:

The batteries of the VAS 5051B and the VAS 5053 automatically detect whether a main-tenance cycle needs to be performed. On starting up and with each change back to the start mask, the tester displays a query asking whether to start a maintenance cycle. If you confirm it with "Yes", the "Battery service" function starts automatically. If you answer with "No", you can continue to work with your tester as usual.

When you start battery service, the tester asks you to secure the power supply. This is necessary so that it can charge the battery completely first and then recharge it again after discharge. If it does not detect the power supply, it cannot start battery service. When you have confirmed the message, a security query appears again, giving you the last opportunity to cancel the maintenance cycle. If you confirm it with "Yes", the tester finally starts the maintenance cycle. No operation is possible during this time.

The tester is not switched off during the service process and can be used in the normal manner when a battery charge of approx. 30 % is reached. An appropriate message appears.

With the VAS 5053, you can only start battery service if it is really necessary, i.e. when the tester prompts you to do this. Otherwise, the function is canceled after being acti-vated.

VAS 5052 sequence:

With the VAS 5052, battery service can only be started manually. It is recommended to do this every two to three months. It is is applied too frequently, this reduces the service life of the battery, since it can only perform a limited number of charge/discharge cycles. You also start this maintenance when the battery's capacity has been reduced noticea-bly.

Page 211: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-47A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Disconnect the tester from the power supply when you are asked to do so by pulling the mains plug on the docking station. When you start battery service by pressing "Con-tinue", the tester starts the maintenance cycle without delay and without security query. No operation is possible during this time.

The tester discharges the battery almost completely and shuts down. Reestablish the power supply and charge the battery completely.

9.32 Display battery charging

You can use this function on the VAS 5051B and the VAS 5052 to check the current sta-tus of charge of the integrated battery. A bar display indicates the current charge.

Fig. 9-20 Battery display (example: VAS 5051B)

On the VAS 5052, the "Display battery charging" function rounds the current charge to values of 25%, 50%, 75% and 100%. It does not display any intermediate values.

The VAS 5051B gives you a graphical and a numerical percentage display (see fig. 9-20).

If the battery charge falls to 25% (VAS 5052) or below 20% (VAS 5051B), the indicator bar turns red.

Page 212: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-48A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.33 Switching on erWin documents (only VAS 5051B and VAS 5052)

You can use this function to activate and deactivate the display of ➚erWin documents. After activation, the "erWin" button appears in the start mask, which you can use to read the erWin information from a CD that is inserted. The erWin CD must always be inserted for this.

If you select this function in administration, your display switches to "Switch off erWin doc-uments". This activation hides the "erWin" button on the start mask.

9.34 Partner application (VAS 5053)

The VAS 5053 does not have a hard disk nor a DVD drive. For this reason not all Admin-istration functions can be carried out directly from the VAS 5053.

Basically these are the following functions:

• Loading new software (base CD, brand CD, flash data)• Display of the user documentation• On-line updating of software from a workshop server

These and other functions can be executed via a "partner application" from a communi-cation partner (VAS 5051B, VAS 5052 or a workshop PC).

The VAS 5053 is here connected to the partner device via the USB cable supplied. The software for the partner is included on the VAS 5053 base CD.

For additional descriptions, see /4/.

Page 213: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-49A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

9.35 Configuration of vehicle communication

This function switches between wired ("internal") vehicle communication via the diagnos-tic cable and wireless ("external") communication via the diagnostic head VAS 5054.

The testers VAS 5051B and VAS 5053 have already been prepared with the radio tech-nology for wireless vehicle communication by default. The VAS 5052 must be equipped with a USB Bluetooth adapter for this purpose. The connection and handling of wireless communication can be taken from the description that is enclosed with the relevant doc-uments. The VAS 5054 can also be connected to the tester via USB cable.

After switching on the tester the "internal" configuration is preset. For communication via the VAS 5054, select "external" as connection type.

Establishing a radio connection with the VAS 5054

• When you select "external" for the first time, the "Country selection" mask appears. Enter your country. The country selection is not repeated during future activation.

• The mask for displaying the available diagnostic heads is displayed (still blank).• To recognise the available diagnostic heads, these must be connected to the power

supply (connect the VAS 5054 to the diagnostic socket on the vehicle and switch on the ignition).

• Press the "New search"button to activate the available diagnostic heads: "VAS 5054 <name> <serial number>". VAS 5054 devices already connected to other testers are not displayed.

• Select the desired VAS 5054 and press the "Connect" button. • A dialog box appears for entering the PIN. Select the "PIN:" field. A virtual keyboard

appears for entering the identification number of the VAS 5054 (you are given this number along with the tester). The entered PIN is stored on the tester until you acti-vate another VAS 5054 or the PIN no longer matches the VAS 5054 connected.A correct connection setup is displayed at the top, in the work window. The "Config-ure" button appears next to it. This button can be used e.g. to change the PIN.

• When you switch to the "Guided Fault Finding" and "Guided Functions" operating modes, the radio connection to the VAS 5054 is checked. A warning appears if there is no connection

The "external" connection is maintained until it is switched to "internal" or the tester is switched off.

If a connection to the VAS 5054 cannot be established correctly, disconnect it from the vehicle once and reestablish the connection.

Page 214: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-50A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Configuring

You can use "Configure" to display and change the VAS 5054 settings:

Fig. 9-21 "VAS 5054 Configuration" mask

• Local Name:You can change the name of the VAS 5054 here, e.g. to be able to distinguish multiple diagnostic heads more easily. The name is automatically added to the serial number.

• PIN:You can change the PIN number of the VAS 5054 here.

• Timer Buzzer: If the connection to the tester is disconnected while the diagnostic head is switched on (ignition on), the buzzer of the VAS 5054 sounds when the set interval passes. The value "0" switches the buzzing off.

• Security Mode and Timer Power Off: Both values are fixed values that cannot be changed.

• OKPress "OK" to accept the changed settings.

• Set standardThis reactivates the original default settings, including the PIN number.

After accepting the settings, you are asked to disconnect the diagnostic head from the vehicle once and reconnect it.

Warning!

Only select the "Set standard" function if you still know the original PIN number.

Page 215: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Administration

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.9-51A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Connection via USB cable

On selecting "external", a VAS 5054 with USB connection is searched for. If there is one, a message appears. Then you need to restart the tester. The message will no longer appear in the future for this VAS 5054.

After restarting the tester, you can operate the VAS 5054 via the USB connection. The LED of the VAS 5054 indicates the type of connection: It flashes for radio operation and lights up constantly for USB operation.

Now establish the connection by selecting "external" again. The existing USB connection is displayed at the top, in the work window. If there is a USB connection, there is no auto-matic search for other VAS 5054 devices that are available.

Disconnecting the VAS 5054

Selecting "internal" disconnects the VAS 5054. It can be reconnected to the same tester or a different tester.

Page 216: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Help

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.10-1A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

10 Help

10.1 Overview

The context-related general operating instructions and function explanations can be called with the Help function. The Help function does not replace the operating manual but it can still be useful in the workshop in the event of uncertainty in using masks and buttons, saving you acccessing the manual.

10.2 Starting and closing Help

Every mask of the tester has the Help button. It is always at the same position on the navigation bar. Press this button to open the help overview (section 10.3). When you close the help overview, the Help function stays active until you press the Help but-ton a second time. In this mode when you touch a button you get "Help with button pressed" (section 10.4).

Help is activated - the but-ton is latched

Help is not activated

Page 217: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Help

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.10-2A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

10.3 Help Overview

The "Help Overview" dialog appears after starting the Help function. It offers a list of one or more topics for which brief information is available (see fig. 10-1).

A selection bar highlights the current topic. You can move the bar to any entry in the list; the selected topic will be opened once you activate the touchscreen.

Fig. 10-1 Help overview in the "Test plan" mask, Guided Functions operating mode

The Close button closes the "Help Overview" to reveal any buttons underneath it. However, the tester stays in the Help function.

Help on use of the mask

Help with using the mask (for an example, see fig. 10-2) explains what the mask is for, the symbols on it, and the functions of the buttons which are available.

Fig. 10-2 Help on use of the mask

Page 218: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Help

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.10-3A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

• If the help text in this mask cannot be displayed in its entirety, you can move it up and down with a scroll bar at the right of the screen to read parts which are not visible.

• The Overview button calls the "Help Overview" again.• The Close button closes the Help dialog to reveal any buttons underneath it. However,

the tester stays in the "Help" mode.

Help with function test

The help for the function test opens help text on the selected function test It includes more explanatory material about the function test provided a help text is available in the program. The following cases are distinguished:

• "Help for the function test" in the test plan: If you select a function test in the test plan and open the corresponding help, you are given general information on the se-lected function test (if available).

• "Help for the function test" during a function test: Help text can be stored at any points in the function test. Observe appropriate messages or check whether a re-quired help text is available as required. As a rule, help text is displayed via the doc-ument display.

Page 219: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Help

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.10-4A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

10.4 Help on pressed button

You can have help displayed for the available buttons in every mask.

You press any visible button while the tester is in the Help function and a brief informa-tion of its meaning and use in the respective mask is output in a dialog box (see fig. 10-3).

Fig. 10-3 Help with Test Instruments button pressed (VAS 5051 / VAS 5051B only)

• The Overview button calls the "Help Overview" again.• The Close button closes the "Help on pressed button" dialog box to reveal any buttons

underneath it. However, the tester stays in the "Help" mode.

NoteYou cannot call help for the Overview, Close and Help buttons themselves.

Page 220: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-1A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

11 Abbreviations and terms

Table 11-1 Terms and explanations

Term Explanation

Acoustic signal A beeping or whistling tone created by the tester when, for example, the voltage of the battery reaches a limit value in buffer mode.

Adaptation This service permits interactive modification of parameters of the control system addressed and can save these new values (such as correction values for idling speed) in the control units, even perma-nently.

The user has the possibility of changing the value and transferring it to the control unit RAM for checking. The control unit now applies the new value to its outputs and the user can check the reaction of the system. If the right correction value has been found, the tester has the control unit transfer the value and the workshop code to the writeable EEPROM.

In contrast to the ➚basic setting, the control loop in question is in a closed state. With adaptation, system-specific parameters are determined and saved in the vehicle system.

Adaption values Setting values stored in the ➚control unit which can be adapted to the vehicle within a fixed range.

Administration An ➚operating mode of the VAS 505x. It is used for management of the tester.

Alphanumeric keyboard

Keyboard which can be used to enter numbers and text. ➚Numeri-cal keyboard, ➚Hexadecimal keyboard.

Ambient condi-tions

In addition to supplying the fault memory entries, newer control units also deliver so-called ambient conditions, containing further ambient parameters relating to the error. The ➚time stamp may also be contained here.

Amplitude The maximum displacement possible for the oscillation of, for example, an alternating current or alternating voltage.

Application oper-ating modes

These include: ➚Vehicle Self-Diagnosis, OBD, ➚Guided Fault Finding and ➚Guided Functions.

Applications An operating mode of the VAS 505x. In this operating mode you can start applications which are loaded onto the tester, e.g. Service training.

Page 221: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-2A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

ASAM-ODX Association for Standardisation of Automation and Measuring Sys-tems - Open Diagnostic data eXchange.ASAM ODX electronic control units are built in LT3 commercial vehicles in accordance with this standard. The diagnostic proce-dure and the diagnosis data can differ from those of the electronic control units in the ➚protocols KWP1281/2000/6000, e.g. with the fault memory contents. ASAM ODX electronic control units work in accordance with the ➚UDS protocol.

Base CD Installation CD. It contains the operating system, ➚Vehicle Self-Diagnosis, and the programs of the various ➚operating modes. The CD can also take the form of an update CD. In this case it only contains software components which have been changed. ➚Brand CD.

Basic features The vehicle is identified by the basic features model, year of make, variant and engine code. Its fittings, on the other hand, are deter-mined in the vehicle system test.

Basic setting ➚Control units are adapted to the peripheral devices with the basic setting.

Bluetooth Wireless communication link for the more immediate vicinity.

Brand CD Installation CD containing vehicle-specific data (➚Guided Fault Finding). ➚Base CD.

Buffered The power supply of the tester is buffered, i.e. a built-in battery takes over the power supply for a limited time in the event of a mains failure or when the working position is changed without the mains cable being connected.

Calibration(Test Instruments)

Correction of a measurement deviation in a testing device (e.g.: current pick-up).

CalibrationTouch screen

Sets the ➚touch screen so that the actual position of the points touched corresponds to the coordinate values transmitted to the PC.

CD-ROM Compact Disk - Read Only Memory: Data carrier for mass data. A CD can also be read by a ➚DVD drive.

Channel number Number of a measured value channel in the ➚control unit.

Client A program on your PC which provides the connection to a ➚server. A network client for example is the program which makes the con-nection to a server in the network so that you can operate your PC as a workstation in the network.

Table 11-1 Terms and explanations

Term Explanation

Page 222: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-3A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

COM Short for "common", corresponds to "earth" or "0 V"; testing devices input.

Control unit Electronic device for controlling and monitoring vehicle functions, e.g. motor control unit. ➚Vehicle system.

Data block ➚Display group.

Degree of suspicion

The order in which ➚diagnostic objects are suspected of having faults.

Deselection, deselect

Cancelling of a selection of program functions or list entries. ➚Selection.

DHCP Short for "Dynamic Host Configuration Protocol". DHCP is a server service which ensures that network clients are automatically allo-cated an IP address and further IP settings.

Diagnosis The entire process of attributing ➚fault characteristics to possibly faulty functions, component groups or components and localising a faulty component. In VAS 505x, diagnosis is based on the ➚fault memory entries read from a ➚vehicle system, on selected cus-tomer complaints, direct function and component selection, or com-bined procedures.

Diagnosis object Collective term for functions, component groups and components on which the diagnosis function is carried out.

Diagnosis socket Connection socket for the ➚diagnostic cable on the tester or on the vehicle.

Diagnostic cable Connecting cable between the vehicle and the tester.

Diagnostic strat-egy

Course taken by Guided Fault Finding on the basis of the informa-tion available about a fault, such as:1. Fault codes read from vehicle systems2. Complaint messages (terms describing symptoms or fault pat-

terns selected by the user from terms shown in masks) or3. functions and components of the vehicle selected by the user in

masks as possible sources of the fault, ➚user test plan.The three entries, either individually or combined, lead to a calcula-ted test proposal in the test plan. The strategies (1.) and (2.) are designated as system-guided fault finding, while (3.) is designated as user-guided fault finding.

Diagnosticradio head

This device permits wireless diagnostic operation between vehicle and VAS 5053 via a ➚bluetooth or WLAN interface.

Table 11-1 Terms and explanations

Term Explanation

Page 223: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-4A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Dialog box Information field on the screen, displays messages and expects user inputs.

Display group A fixed group of measured values which can be read out of a vehi-cle system.

DNS In this case the name of the workshop domain (domain name ser-ver).

Document Documents in the tester containing information (images, text) that can be used as needed by the user.

DSO Digital Storage Oscilloscope

DTC Diagnostic Trouble Code. Fault memory entry consisting of fault location, fault type and eventually ambient conditions.

DVD Digital Versatile Disk: a data carrier externally similar to the ➚CD but with a larger storage capacity.

ECU Electronic Control Unit.

ECU identifica-tion data

A printable log file which is created during vehicle identification. It contains control unit identification data such as control unit desig-nation, software part numbers, and so on.

ELSA, Elsa Win ELSA is a workshop information system which runs under MS Win-dows. It includes information about service, drive, chassis and bodywork, meaning of fault memory entries, repair instructions, and circuit diagrams. ELSA runs as an application on the tester. Follow-ing first-time installation, which must be carried out by the user, the "Elsa Win" run-time system is installed and an additional button, "Elsa Win" appears in the start mask. After this, the user has to install the actual ELSA data.

End module An end module can consist of one or more ➚function tests which are started automatically when quitting ➚Guided Fault Finding. This is used to provide feedback to the vehicle manufacturer, for example.

Energy-saving mode (stand-by mode)

Advanced Power Management (APM): a function for saving energy. If the tester is not used for a certain time the screen switches off. Once the screen is touched (do so at the top left-hand edge to avoid making unwanted inputs) the tester returns to its nor-mal operating state.

erWin erWin is the Electronic Repairs and Workshop Information of the Volkswagen company for independent workshops.

Table 11-1 Terms and explanations

Term Explanation

Page 224: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-5A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Ethernet The most common form of network. Here the connected computers exchange signals via a cable or another medium. Each one checks to see if the other is currently transmitting, and sends his own sig-nals if not.

Experience rules If workshop experiences (field experiences) with the diagnostic system are communicated to the diagnostic author, it can convert them into so-called E. and bring them into the diagnostic system. Often these are complex fault symptoms consisting of a unique combination of fault memory entries and any additions communica-ted by the customer. If the described experience situation occurs in the workshop, the tester can now recognize it automatically and put the relevant suspicious diagnostic objects into the test plan.

Fault character-istics

The entire effects (➚fault symptoms) of a fault scenario in vehicle functions, component groups or components.

Fault memory Data memory of the ➚control unit in which all detected faults are stored non-volatile.

Fault symptom A describable effect of a fault scenario in the vehicle functions, component groups or components. The symptoms make up the ➚fault characteristics. Known symptoms assigned to suspect ➚diagnostic objects are stored in the database of the tester. ➚Diagnosis.

Flash CD Data carrier for flash data. On vehicle systems which are flash compatible, its firmware can be updated using a flash CD and VAS 505x. This procedure runs automatically in the Vehicle Self-Diagnosis when the vehicle system is selected. If the VAS 505x finds an older version of the firmware in the vehicle system compared to the version on the inserted flash CD (cannot be installed) or the flash data saved on the VAS 505x, the "Update programming" function will become available. The flash procedure is then carried out through several masks.

There are also flash CDs which can be installed. In this case, you can save the flash data on the hard drive of the VAS 505x, using the Administration function "Update Installation"; then, the data will be available at any time for comparing firmware versions by calling up Vehicle Self-Diagnosis.

Flash data The flash data consists of loadable program components for a ➚vehicle system. The tester offers various ways of comparing the version of the flash data in the vehicle system and loading more recent data onto it.

Table 11-1 Terms and explanations

Term Explanation

Page 225: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-6A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Floating No connection to the power supply or to the grounding.

Function Every activity which the tester can perform in its different ➚operating modes. Individual functions are usually selected from a list displayed on the screen.

Function test A test program with which functions, component groups or compo-nents can be checked as to whether they meet requirements. The function test also can be used for a repair check.

Gateway installa-tion list

The vehicle systems installed in the vehicle are known to a gate-way control unit. It monitors the vehicle systems and draws up a status list. By interrogating the gateway installation list it is possible to find out for a vehicle system whether its fault memory is set, whether it is registered (coded), or whether communication is pos-sible.

The installation list is evaluated as part of vehicle identification and all in all results in a more powerful identification process.

GeKo test Way of testing the code clearance and user logon for online access (confidentiality and component protection).

Guided Fault Finding

An operating mode of the VAS 505x. Here the diagnostic proce-dure is embedded in an optimised run sequence consisting of vehi-cle identification, vehicle system test, ➚test plan and ➚function tests.

Guided Func-tions

An ➚operating mode of the VAS 505x. This makes possible fast access to the customer service functions for the vehicle identified, e.g. "Adapt valve throttle control unit".

Hardware Hardware primarily refers to the device itself with its mechanical structure, display and control elements, and also the basic opera-tion.

Hexadecimal keyboard

Keyboard with which only numbers and letters A to F can be input. ➚Alphanumeric keyboard, ➚Numerical keyboard.

Information win-dows (left and right)

The information windows are located in a mask above the ➚work window. The left-hand information window generally contains the following information: ➚operating mode, active function, task.The right-hand information window shows the currently selected components or status messages (operating mode ➚Test Instru-ments) or a separate selection list of control units working in con-junction (operating mode ➚Vehicle Self-Diagnosis).

Table 11-1 Terms and explanations

Term Explanation

Page 226: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-7A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Initial graphic Exchangeable image of a vehicle which appears in the ➚Start mask.

Inline current measurement

Current measurement in which the tester is used as an ammeter directly in the circuit. Opposite: Inductive current measurement via a current pick-up clamped on the cable.

IP address Short for "Internet Protocol Address". Every computer which is con-nected to a computer network (TCP/IP) has a unique IP address. It consists of four groups of numbers which are separated by points (e.g. 194.0.0.135). IP addresses can be allocated automatically by ➚DHCP servers.

IrDA Infrared Data Association. The IrDA interface can create a wire-less, infrared contact between the tester and a printer.

ISDN Short for "Integrated Services Digital Network". Designation for a digital telephone network which is conceived for telephone calls, remote data transmission, faxes and other services.

Job code A unique combination of symbols and letters used to identify inter-rupted and saved diagnosis jobs.

Key CD CD which holds the key code to the expanded functions. It needs to be inserted in the CD/DVD drive for expanded functions to become accessible.

LAN Local Area Network.

Mask Screen display with fixed division into various graphic elements such as windows, buttons, scroll bars etc.

Measurement type

In ➚Test Instrument mode, the measurement type defines whether the measurement is executed with DC voltage or AC voltage. In ➚Guided Fault Finding mode the measurement type determines whether a current or a voltage is measured in a ➚function test.

Mirror server A software package that can be saved locally, for example on the dealership server, to provide data such as the update program for the VAS 505x when required. The dealership server is connected to the central office and receives the current updates from there. Within a workshop, each tester connected to an ➚LAN fetches the current programs automatically when it is switched on, or when the Administration function "Net-update" is carried out.

Mode, Modes The current operating state of the tester, or its program.

Table 11-1 Terms and explanations

Term Explanation

Page 227: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-8A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Navigation bar Functions in the bottom part of the ➚mask to change from the cur-rent mask to other masks and to offer help, save and print func-tions.

Non-VW vehicle Any vehicle type which is not part of the Volkswagen company.

Numerical key-board

Keyboard which can be used to enter numbers but not letters. ➚Alphanumeric keyboard, ➚Hexadecimal keyboard.

OBD vehicle systems

Vehicle systems of the "On-Board Diagnosis" system, which is integrated into the engine management system and constantly monitors the components related to the exhaust.

Old vehicles Older vehicle models for which no diagnostic data is available (also termed "non-included vehicles"). Only the vehicle identification with vehicle system test and sometimes a few customer-specific instruc-tions are available for old vehicles which appear in the ➚masks for entering ➚basic features.

Online connection

External connection, e.g. to the Internet or to the VW server.

Online feedback log

A log which is sent online to the vehicle manufacturer.

Operating mode All the basic functions of the tester which can be called from the ➚Start screen: ➚Vehicle Self-Diagnosis, ➚OBD, ➚Test Instru-ments, ➚Guided Fault Finding, ➚Guided Functions, ➚Administra-tion and ➚Applications. Every operating mode is subdivided into a number of individual ➚functions.➚Application operating modes

Oscilloscope Measurement and display device for electrical signals that displays the time characteristic of the signal strength (e.g. oscillations).

Partner applica-tion

The partner application makes administrative functions available to the VAS 5053 (such as ➚update, screen calibration, and so on). The partner application is installed either on a workshop PC or on a VAS 5051B / VAS 5052.

PCMCIA cards (Personal Computer Memory Card International Association) cards of credit card size used above all for installation in laptops or notebooks. PCMCIA is the standardised interface with which these devices must comply. There are for example, network cards, ➚ISDN cards or modems as PCMCIA cards. In the latest version, the standard is called PC-Card-Standard.

Permanent error ➚Unlearning counter.

Table 11-1 Terms and explanations

Term Explanation

Page 228: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-9A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Preselection The suggestion of the tester to call up one of several functions from the current ➚mask. The preselection is shown by a black bar on the screen. You can change it at any time.

Protocols KW1281, KW2000, KW6000➚UDS

Keyword protocols specify the precise procedure to be used for the exchange of data between the control unit and the tester. Older control units use the KW1281 protocol to communicate while newer control units use KW2000 or KW6000 (CAN diagnosis); ASAM electronic control unit use ➚UDS. In Vehicle Self-Diagnosis the tester automatically ascertains the keyword protocol variants for a control unit before selection of the diagnostic functions.

Proxy server Proxy servers receive the requests made by a client and forward their data (sometimes modified) to the original target. Proxies can also save data locally on a temporary basis, for future accessing (cache).

Quit The reply to a question of the tester whereupon a function or a dia-log is ended.

Readiness code 8-position binary code which indicates whether all diagnostics rele-vant to exhaust gas have been run through by engine manage-ment.

Removable stor-age device

Depending on the tester type, data is saved to diskette and/or ➚USB memory stick. If both storage media are connected, output to the USB memory stick will be preferred.With the VAS 5051 output to USB memory stick is not possible but you can use all USB memory sticks recommended by VW with other testers.

Reverse polarity Switching of the connecting leads for the power supply.

Run-time system The software installed in the tester.

Screen shot (hardcopy)

Hard copy of the screen contents ( ➚masks etc.).

Scroll bar If the complete text cannot be shown in a ➚dialog box or a ➚mask, a scroll bar will appear on the right-hand side.

Selection Selection of a program function or a text entry from a list. The selected element is identified by a black bar on the screen. ➚Deselection.

Selection bar Emphasises a selected line by inverting the colours.

Table 11-1 Terms and explanations

Term Explanation

Page 229: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-10A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Self-diagnosis ➚Vehicle systems can also carry out self-diagnosis. They have methods of constantly checking their own functions, connected ➚sensors and actuators. A fault results in an entry being made in the ➚fault memory of the vehicle system. The tester knows all the faults saved in its knowledge base, so that on reading the fault memory it is able to attribute the fault code to a fault type and a fault location and thus to make a test suggestion.

Sensor Device which records measured values.

Server In computer technology the server describes a central network computer. This provides the ➚clients with the appropriate services and data.

Shutdown delay The time between activating the On/Off switch to switch off the tester and when it actually switches itself off. The delay is about 10 seconds.

Sporadic error ➚Unlearning counter.

Start mask The display which the tester shows on the screen after starting operation. Its operating modes can be called from here. Recognis-able from the ➚initial graphic.

Start module A start module can consist of one or more than one ➚function tests which are started automatically after the vehicle system test. They are use to check e.g. whether there is new flash data for a vehicle system.

Startup Activity of the tester between switching on and first display of the ➚Start mask, includes loading of data, a self-test, etc. During this time no entries are possible.

Station name A tester connected to the ➚LAN requires a unique name for the network. As standard, the tester is given the name e.g. VAS5051. You can display the station name currently set by selecting the function "Display network settings" in ➚Administration, Network settings. If there are several testers of the same type in the network, their names must be different.

Subnet mask All computers connected to a network (TCP/IP) have a subnet mask. It consists of four groups of numbers which are separated by full stops (for example, 255.255.0.0).

Table 11-1 Terms and explanations

Term Explanation

Page 230: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-11A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Test Instruments An ➚operating mode of the VAS 5051 / VAS 5051B. You can use the Test Instruments to carry out measurements yourself, the results of which are then displayed on the tester numerically or graphically. A multimeter and an ➚oscilloscope (DSO) are avail-able.

Test plan In Guided Fault Finding and Guided Functions the ➚diagnostic objects are added to the test plan during the diagnosis session and managed. Particularly in the case of multiple suspicious diagnostic objects the test plan allows the user to keep an overview of things.Each diagnostic object is preceded by a status symbol. The diag-nostic objects are added to the test plan via read-out fault memory entries, selected observations, or the function and component selection. In addition, new diagnostic objects can be added to the test plan even from a function test or existing ones set to OK.

Test step A single, complete stage in a ➚function test.

Time record The time taken for the diagnosis session is calculated. This occurs in part by recording times which have actually elapsed, and through standard times for particular actions. In the individual phases of the ➚Guided Fault Finding, the time is calculated, added up and written into the diagnosis log in temporal units.

Time stamp Control units of the new generation will provide ➚ambient conditions as well as fault memory entries. These include the time stamp. It contains the date and time at which the corresponding fault occurred.

Touch screen A screen which has a touch-sensitive surface. The corresponding hardware and software reacts to it being touched with a touch pen or finger, detects the place touched and launches the ➚function linked with this location (a button, for example). The touch screen replaces externally connected input devices such as keyboard, mouse, and so on.

Trigger level Voltage value at which the measurement of a test signal character-istic is started.

Trigger signal The signal used to start the graphing process of a test signal char-acteristic.

UDS Unified Diagnostic Services; a unified ➚protocol for electronic con-trol unit communication setup, building on KW2000 for ➚ASAM ODX electronic control units.

Table 11-1 Terms and explanations

Term Explanation

Page 231: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-12A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Unlearning counter

Should an error occur during a driving cycle (terminal 15 on until terminal 15 off) it is first entered as "static" in the fault memory. If it is not detected during the next driving cycle, the designation is changed to "sporadic" and an unlearning counter with an output value of, for example, 40 is decremented by 1. This is repeated during each driving cycle free of the fault, until the unlearning counter reaches 0 and the fault is thus automatically cleared. How-ever, if the registered fault should reoccur during a later driving cycle, then the unlearning cycle is set to its output value and the error provisionally set back to "static" again.

Update Software modification package for updating an existing program to a later version.1. New version of the ➚run-time system which is downloaded from

➚CD.2. New program version of a ➚vehicle system which is imported by

the tester.

URL Abbreviation of "Uniform Resource Locator". A URL corresponds to the address of an internet resource (web site, file, etc.). Example: www.siemens.com

USB Universal Serial Bus. USB is a standardized interface for connect-ing, for example, keyboard, ➚USB memory.

USB storage device

Also known as USB memory stick. A mobile, easy to handle mem-ory unit with a USB interface. It is plugged into the USB port on the tester and is detected automatically by the tester. Assignment takes place with the function "Set output medium on removable storage device" (navigation bar, print). Now you can send, for example, logs or screen shots to the USB memory.

User test plan ➚Diagnostic strategy based on the selection of descriptions of pos-sible defective functions and components by the user. If faults in the vehicle system are detected during diagnosis or a complaint report is entered, the test plan differentiates between the system test plan and a user test plan.

Table 11-1 Terms and explanations

Term Explanation

Page 232: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Abbreviations and terms

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.11-13A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Release: 2007-02-05

Variant,variant rule

This term is used with reference to the ➚vehicle system fittings. Some fittings, for example an airbag, may be available in various variants for an identified vehicle. The most important task of the vehicle system test is to find out which variant is actually installed. If the variants cannot be determined automatically, Yes/No questions on the fitting will follow, e.g. "Automatic gearbox?". The mechanisms used to determine the variants are known as variant rules. Their results determine which diagnosis data should be made available, amongst other things.

Vehicle identifi-cation

Vehicle identification is defined by the vehicle's ➚basic feature components (type, model year, body version, engine code) that can be determined automatically or partly automatically in an existing gateway. These data are used to check a list of all possibly installed electronic control units/devices and their installation in the ➚vehicle system test.

Vehicle Self-Diagnosis

VAS 505x operating mode in which you can communicate with the ➚vehicle systems available in the vehicle and carry out a thorough ➚diagnosis, via dialog boxes.

Vehicle system A ➚control unit of a known name, e.g. motor control unit, including the appropriate ➚sensors, actuators and wiring.

Vehicle system test

A list of all possibly installed vehicle systems (electronic control units, devices) is generated from the ➚vehicle identification. In the vehicle system test, all systems are examined for availability and their error status is queried. If necessary, inquiries about equipment appear here also.

Virtual keyboard The graphic representation of a keyboard on a ➚screen. The indi-vidual buttons can be operated by touching them with a touch pen in the same way as those of a real keyboard.

Work window The work window takes up the largest part of the ➚mask. The display changes according to the ➚operating mode and cur-rent progress. Here you can make a selection, or view results (e.g. from ➚Test Instruments).

Table 11-1 Terms and explanations

Term Explanation

Page 233: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Index

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.12-1A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

12 Index

A

AC .............................................5-22, 5-28Accept ................................................6-27Acknowledge ("Quit") .........................3-12Acoustic signal ...................................11-1Adaptation ..........................................11-1Adaption values ..................................11-1Add printer (USB printer) ....................9-44Administration .............................9-1, 11-1Aknowledge ("Quit") ...........................11-9Alphanumeric keyboard .....................11-1Alternating voltage ...............................5-5Ambient conditions .............................11-1Amplitude ...........................................11-1Amplitude difference ..........................5-33Application operating modes .......5-2, 11-1Application statistics ...........................9-34Applications ........................................11-1Applications with start button .............9-35Arrow ....................................................3-7ASAM-ODX ........................................11-2Auto ...........................................5-25, 5-39Auto level ..................................5-25, 5-39Auto setup ..........................................5-25Automatic vehicle identification ..........6-10

B

Backward ...........................................9-25Bandwidth limiting ..............................5-30Base CD ......................................9-6, 11-2Basic features ....................................11-2Basic settings ............................5-18, 11-2Bluetooth ............................................11-2Brand CD ...........................................11-2Brief instructions ................................ I-VIIIButtons ...................................3-2, 3-5, 3-8BWL ...................................................5-30

C

C ........................................................3-12Calibration .................5-5, 5-15, 5-17, 11-2

Touch screen .................................11-2Cancel function test ...........................6-49CentralPartnerNet-password .............9-37Change dealership identifier ................2-6Channel A, B ......................................5-20Channel number ................................11-2Client ..................................................11-2COM ...................................................11-3Compatibility number ...........................9-5Complaint message ...........................6-25Complaints ...........................................6-4Contents list, base and brand CDs ....9-16Continuity test ....................................5-10Control unit .........................................11-3Coupling .............................................5-22Cursor ..................................................3-7Cursor 1, 2 ................................5-30–5-32

D

Data block ..........................................11-3Date/Time ...................................2-6, 9-16DC .............................................5-22, 5-28Dealership identifier .............2-3, 2-5, 9-14Decimal keyboard ..............................3-14Definitely installed control unit not re-cognised .............................................6-17Degree of suspicion ...........................11-3DHCP .................................................11-3Diagnosis ...........................................11-3Diagnosis connection .........................11-3Diagnosis object .................................11-3Diagnosis protocol .............................6-57Diagnostic cable .................................11-3Diagnostic head .................................9-49Diagnostic radio head ........................11-3Diagnostic strategy ............................11-3Dialog box ...................................3-5, 11-4Digital Storage Oscilloscope ..............5-18

Page 234: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Index

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.12-2A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Dimension pressure / temperature .....9-35Diode

in forward direction .........................5-13in reverse direction .........................5-13interruption .....................................5-13short circuit .....................................5-13

Diode test ...........................................5-12Direct voltage .......................................5-5Display documents .............................6-41Display group .....................................11-4Display target URL .............................9-38DNS ....................................................11-4Documents .........................................11-4Draw mode .........................................5-26DSO ...................................................5-18DSO1 ........................................5-21, 5-28DSO2 ........................................5-21, 5-28DTC ....................................................11-4DVD ....................................................11-4

E

ECU identification data .......................11-4ELSA

Administration ................................9-33Installation ......................................9-33

Elsa Win .............................................9-33ELSA, Elsa Win ..................................11-4End module ..........................................6-4Energy-saving mode ..........................11-4Engine code .......................................6-10Enter ...................................................3-12Enter job code ....................................6-52Entering vehicle ID no./licence plate no. 3-18erWin ..................................................11-4ESIS ...................................................9-22Ethernet ..............................................11-5Expanded functions ............................9-16Experience rules ................................11-5Export problem log ...............................6-9External applications ..........................9-35Extreme values ...........................5-6, 5-24

F

Fault characteristics ...........................11-5Fault memory .....................................11-5Fault memory contents ...............6-2, 6-20Fault symptom ...................................11-5Flash CD .....................................9-8, 11-5Floating ..............................................11-6Forward ..............................................9-25Freeze Frame ......................................5-5Freeze frame ......................................5-42Function .............................................11-6Function test ......................6-3, 6-39, 11-6Function test files ...............................9-43Function test protocol .........................6-58Function/Component selection ...6-4, 6-30Function-test files ...............................9-43

G

Gateway installation list ..............6-2, 11-6GeKo test ..................................9-40, 11-6GND ...................................................5-22Go to .............................................6-6, 6-8Guided Fault Finding ...................6-1, 11-6

exiting .....................................6-3, 6-55Guided Functions ...............................11-6

H

Hardcopy ............................................11-9Hardware ...........................................11-6Help ....................................................10-1

on button pressed ..........................10-4overview .........................................10-2with button pressed ........................10-2with function test ............................10-3with use of the mask ......................10-2

Hexadecimal keyboard ....3-15–3-16, 11-6HF ......................................................5-28Hotspots .............................................6-35Hourglass .............................................3-7

Page 235: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Index

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.12-3A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

I

Image position ....................................5-19Importer number ...................................2-3Incremental updates .............................9-6Information window .....................3-3, 11-6Initial graphic ......................................11-7

select ..............................................9-16Inline current ........................................5-7Install update ........................................9-5Installation

applications ....................................9-35brand CD .................................2-10, 9-8flash CD ...........................................9-8

Interrupt ..............................................6-51IP address ........................9-28, 9-36, 11-7IrDA ....................................................11-7ISDN ...................................................11-7ISDN protocol .....................................9-40

J

Job Administration ..............................6-54Job code ....................................6-52, 11-7

K

Key CD ...............................................11-7Keyboard

decimal ...........................................3-14hexadecimal ..........................3-15–3-16

Keyboard assignment ........................9-45Keyboard for applications ...................3-16kV ..............................................5-21, 5-28

L

LAN ....................................................11-7LF .......................................................5-28Load diagnosis job .............................6-53Long-term measurement ....................5-34

M

Manual vehicle identification ..............6-12Mask ...........................................3-2, 11-7Measurement channel connection .....5-21Measurement cursor 1, 2 ..........5-31–5-32Measurement range ...........................5-21Measurement type .............................11-7Measuring instruction .........................6-43Measuring mode ................................5-25Min / Max ..................................5-20, 5-24Min/Max .............................................5-24Mirror server ................................9-9, 11-7Mode ..................................................11-7Model year .........................................6-10Modes ................................................11-7Moving the curve ................................5-22Multimeter ............................................5-3

N

Navigation bar .............................3-8, 11-8neg. ....................................................5-29Net-update ...........................................9-9Network settings ................................9-36

display ............................................9-37Network update ....................................9-9No trigger ...........................................5-38Normal ......................................5-26, 5-39Numeric keyboard ..............................3-13Numerical keyboard ...........................11-8

O

OBDvehicle systems .............................11-8

OFF ....................................................5-21Old vehicles .......................................11-8On/Off switch

Printer ............................................2-12Online connection ..............................11-8Online feedback log ....................6-6, 11-8Operating bar .....................................9-26Operating manual .....................9-23–9-24Operating mode ..........................6-6, 11-8Operation of the masks ........................3-1

Page 236: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Index

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.12-4A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

Optionally installed control unit not re-cognised .............................................6-17Original size .......................................9-25Oscilloscope .......................................11-8

P

Pause .................................................6-51PCMCIA cards ...................................11-8Pick-up ...............................................5-28pos. ....................................................5-29Preselection ............................11-9, 11-11Preset measurement ..........................5-23Preset measurements ........................5-23Pressure .............................................5-21Pressure T/D ......................................5-15Print ....................................................3-18

Diagnosis protocol .........................3-20User manuals .................................3-20

Print format .........................................9-17Print type ............................................9-18Print/Save ..................................3-19, 9-19Printer ...................................................3-7

Installing additional ........................9-44Printer drivers

Installation ......................................9-44Printing measured values .....................5-1Printing screen shots ..........................3-18Problem log ..........................................6-6Protocols KW1281, KW2000, KW6000 11-9Proxy ..................................................9-39Proxy server .......................................11-9

Q

Q ........................................................3-12

R

Radio LAN ..........................................9-41Reading / writing long coding .............6-11Removable storage device .................11-9Resistance measurement ....................5-9Reversed polarity ...............................11-9

Run sequence for protocol transmission .......................................6-59Run sequence of Guided Fault Finding 6-5Run-time system ................................11-9

S

Safely remove hardware ....................3-18Safety notes .......................................... i-iiSample curves ...................................5-23Screen shot ........................................11-9Scroll bar .....................................3-6, 11-9Secure Client .....................................9-39Select document ................................6-35Selecting measurement ranges ...........5-5Selection ............................................11-9Selection bar ...............................3-6, 11-9Self-diagnosis ..................................11-10Self-test ..............................................9-11

Diagnostic bus unit ........................9-12online connection ...........................9-41Test Instruments ............................9-12

Sensor ..............................................11-10Server ..............................................11-10Setting the date ....................................2-7Setting the time ....................................2-7Signal generator .................................9-15Simultaneous measurements ..............5-4Single ........................................5-26, 5-39Slide control .......................................3-10Software version

base CD ..................................2-1, 9-16brand CD .......................................9-16

Space key ..........................................3-12Special keys .......................................3-12Sporadic error ..................................11-10Sporadic fault .....................................6-21Start module .........................................6-2Start screen ...............................2-9, 11-10Startup .............................................11-10Start-up and unpacking instructions .. I-VIIIStatic fault ..........................................6-21Station name ...........................9-37, 11-10Stop modul .........................................6-58Subnet mask ....................................11-10Switchover ...........................................6-6Symbols

Page 237: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Index

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.12-5A5E00330054/030

VAS 5053

VAS 5051B

VAS 5051VAS 5052

continuity test .................................5-11diode test .......................................5-13Test plan ........................................6-38vehicle system test .........................6-19

System expansions ............................9-44

T

Target URL .........................................9-38Telediagnosis .....................................9-28Temp. .................................................5-21Test dialogs ........................................6-43Test Instruments .......................5-1, 11-11Test plan ..........................6-3, 6-36, 11-11Test step ..........................................11-11

message ........................................6-40question .........................................6-40resistance measurement ................6-42

Testerconnecting to vehicle .....................6-14

Time base ..........................................5-19Time difference ..................................5-33Time record ......................................11-11Touch screen ...................................11-11Trigger level .....................................11-11Trigger mode ......................................5-27Trigger point .......................................5-27Trigger signal ...................................11-11Type ...................................................6-10

U

UDS ..................................................11-11Unlearning counter ...........................11-12Update ..............................................11-12URL ..................................................11-12

General ..........................................9-38URL address ......................................9-38URLbrand-specific ..............................9-38USB ..................................................11-12USB memory ....................................11-12User test plan ...................................11-12

V

Variant ................................................6-10Variant rule .......................................11-13Variants ............................................11-13VAS 5054 ..................................9-49–9-51Vehicle identification ........6-9, 6-13, 11-13

confirm ...........................................6-13Vehicle Self-Diagnosis .....................11-13Vehicle system .................................11-13Vehicle system test ..........6-2, 6-15, 11-13Version block .......................................9-5Virtual keyboard .............3-10, 6-42, 11-13Voltage DSO1 ....................................5-14

W

Work window .............................3-2, 11-13Workshop code ...........................2-3, 9-14

Z

Zoom .........................................5-36, 9-24

Page 238: Vehicle Diagnostic, Testing and Information Systems VAS ...obdchina.com/desimg/SW_VAS505XX_UKD_V030.pdf · Vehicle Diagnostic, Testing and Information Systems VAS 505x (5051, 5051B,

Operating Manual VAS 505x Software V03.0 01/07 All rights reserved.A5E00330054/030 12-6

We have checked the contents of thedocumentation to ensure they corre-spond to the status described. Never-theless deviations cannot be entirelyexcluded and we cannot therefore guar-antee complete agreement. The infor-mation in this documentation is howeverregularly reviewed and any correctionsnecessary will be incorporated in thenext edition. We will be grateful toreceive suggestions for improvement.

Products are subject to alterations inshape, equipment and design. For thisreason, no claims may be made on thebasis of the information, graphics anddescriptions contained in this operatingmanual. Reprints, copies and transla-tions of this document, in whole or inpart, may not be undertaken without theexpress written consent of VolkswagenAG and/or the manufacturer with theexception that the user documentationmay be supplied with each tester. Mak-ing available to third parties is not per-mitted. All rights provided undercopyright law are expressly reserved byVolkswagen AG and the manufacturer.Subject to alteration. All rights reserved.

Manufacturer:

VOLKSWAGEN AGKD-WerkstattausrüstungD-38436 Wolfsburg

Copyright Volkswagen AG 2007,Siemens AG 2007

SIEMENS AGAutomation & DrivesIndustrial Automation SystemsA&D AS AP TE SF ASSiemensallee 84D-76187 Karlsruhe

All rights reserved.