Intraoperative Surgical Guidance and Quality Assessment

Immediate FeedbackUltimate

Vascular

Page 2: Vascular - Medistim · Please refer he ser anua or ndications, ontraindications, arnings, recautions, and further specications and descriptions. 4pecications may be changed without

Please refer to the User Manual for indications, contraindications, warnings, precautions, and further specifications and descriptions. Specifications may be changed without notice. For a list of flow probes for other applications, contact your Medistim representative.

FDA 510(k) cleared no. K102595FDA 510(k) cleared no. K040228

Medistim ASA (Head office)Økernveien 940579 Oslo NorwayPhone +47 23 05 96 60

Medistim Danmark ApSGøngetoften 132950 VedbækDenmarkPhone +45 2276 5669

Medistim USA Inc.14000 25th Ave N. Ste. 108Plymouth, MN 55447USAPhone +1 763 208 9852

Medistim Deutschland GmbHBahnhofstr. 3282041 DeisenhofenGermanyPhone +49 (0) 89 62 81 90 33

Medistim Norge ASØkernveien 940579 OsloNorwayPhone +47 23 03 52 50

[email protected]

Medistim UK Limited34 Nottingham South Ind Est Ruddington LaneWilford, NG11 7EPNottingham, UKPhone +44 (0) 115 981 0871

SC

00IN

012,

ver

2, 1

2/15

Medistim MiraQ™ Systems - Imaging & Flow

Standard configuration

System Profile Channel configuration System features

MQC1 Cardiac adapted interface with imaging and flow

Imaging2 Flow1 AUX

Ultrasound Imaging

• B-Mode imaging

• Color Doppler imaging

• Pulsed Wave (PW) Doppler

Transit Time Flow Measurement

AUX/ECG display

Guided Workflow

MQV1 Vascular adapted interface with imaging and flow

Imaging2 Flow1 Pressure

MQU1Cardiac and Vascular adapted interface with imaging and flow

Imaging2 Flow1 AUX 1 Pressure

Medistim MiraQ™ Systems - Flow Only

Standard configuration

System Profile Channel configuration System features

MQC0 Cardiac adapted interface with flow only

2 Flow1 AUX

Transit Time Flow Measurement

AUX/ECG Display

Guided Workflow

MQV0Vascular adapted interface with flow only

2 Flow1 Pressure

MQU0Cardiac and Vascular adapted interface with flow only

2 Flow1 AUX1 Pressure

Customizable

Options MQC1 MQC0 MQV1 MQV0 MQU1 MQU0

2 extra flow channels

1 Doppler channel*

1 extra Pressure channel**

1 extra AUX channel***

2 extra AUX channels

Printer support

Printer support & color printer

DICOM interface

* A system configured with a Doppler channel cannot be combined with an imaging module.** Pressure channels are intended to be connected to a transducer to measure pressure directly.*** AUX channels are designed to receive signals from other monitoring systems, such as ECG and pressure.