If you can't read please download the document
Upload
hakien
View
248
Download
10
Embed Size (px)
Citation preview
IndustrialHydraulics
Electric Drivesand Controls
Linear Motion andAssembly Technologies Pneumatics
ServiceAutomation
MobileHydraulics
Variable displacement pump A4VSO
Sizes 40...1000Series 1, 2 and 3Nominal pressure 350 barPeak pressure 400 bar
RE 92 050/09.97 1/40Replaces: 03.97 and 11.95
open circuit
Features
The variable displacement axial piston pump type A4VSO inswashplate design is designed for open circuit hydrostaticdrives.
The flow is proportional to the input drive speed anddisplacement. By adjusting the swashplate it is possible toinfinitely vary the flow.
Slot-controlled swashplate design
Infinitely variable displacement
Good suction characteristics
Permissible nominal operating pressure 350 bar Low noise level
Long service life
Drive shaft capable of absorbing axial and radial loads
Good power/weight ratio Modular design
Short control times
Through drive and pump combinations possible
Swash plate angle indicator Optional mounting position
Operation on HF fluids under reduced operationalparameters possible
Contents
Features 1
Ordering code 2, 3
Hydraulic fluid 4
Technical data 5Input power and flow 6 ... 8
Installation notes 9
Unit dimensions size 40, series 1 10
Unit dimensions size 71, series 1 11Unit dimensions size 125, series 2 and 3 12
Unit dimensions size 180, series 2 and 3 13
Unit dimensions size 250, series 3 14
Unit dimensions size 355, series 2 and 3 15Unit dimensions size 500, series 3 16
Unit dimensions size 750, series 3 17
Unit dimensions A4VSLO 750 with boost pump, series 3 18
Unit dimensions A4VSO 1000, series 3 19Summary of controls 20 ... 23
Through drive 24
Unit dimensions of combination pumps A4VSO + A4VSO 25
Unit dimensions of combination pumps A4VSO + A10VSO 26Dimensions through drive 27 ... 39
For separate descriptions of the control devices see RE datasheetsRE 92055, RE 92060, RE 92064,RE 92072, RE 92076, RE 92080
2/40 Bosch Rexroth AG | Mobile Hydraulics A4VSO | RE 92 050/09.97
P
Ordering details
E
A4VS
L
O
see RE 92064
see RE 92068in preparation
see RE 92076
see RE 92055
see RE 92080
10
RL
VP
= available
= in preparation
= not available
22
Z
= preferred programme (with short delivery times)(for preferred types see page 39)
30
anti-clockwise
BH
H
see RE 92072
see RE 92060
Hydraulic fluid / version 40 71 125 180 250 355 500 750 1000
Mineral oil (no code)HF hydraulic fluid (with the exception of Skydrol) High-Speed-Version
Axial piston unit
Swashplate design, variable, for industrial applications
Boost pump (Impeller) 40 71 125 180 250 355 500 750 1000
Without boost pump (no code)With boost pump (Impeller) only for version 25
Type of operation
Pump, open circuit
Nominal size
displacement Vg max (cm3) 40 71 125 180 250 355 500 750 1000
Control device
Pressure control DR DR..
Flow control FR FR..
Power control with hyperbolic curve LR LR..
Manual control MA MA..
Electric motor control EM EM..
Hydraulic control, position dependent HW HW..
Hydraulic control, volume dependent HM HM..
Hydraulic control with servo/proportional valve HS HS..
Electronic control EO EO..
Hydraulic control, pressure dependent HD HD..
Speed control, secondary controlled DS DS..
Series
Direction of rotation
Viewed on shaft end clockwise
Seals
NBR (Nitrile rubber to DIN ISO 1629) with shaft seal FPM
FPM (Fluorine india rubber to DIN ISO 1629)
Shaft end
Keyed parallel shaft DIN 6885Splined shaft DIN 5480
Mounting flange 40 71 125 180 250 355 500 750 1000
ISO 4-hole ISO 8-hole
RE 92 050/09.97 | A4VSO Mobile Hydraulics | Bosch Rexroth AG 3/40
Service line connection 40 71 125 180 250 355 500 750 1000
Connections B and S: SAE on side 90o offset, metric fixing screws 13Connections B and S: SAE on side 90o offset, metric fixing screws 252nd pressure connection B1 opposite B - when delivered blanked off with a flange
Through drive
Without auxiliary pump, without through drive N00With through drive to accept an axial piston unit, gear or radial piston pumpFlange Hub/shaft to accept
ISO 125, 4-hole Splined shaft 32x2x30x14x9g A4VSO/H/G 40 K31ISO 140, 4-hole Splined shaft 40x2x30x18x9g A4VSO/H/G 71 K33ISO 160, 4-hole Splined shaft 50x2x30x24x9g A4VSO/H/G 125 K34ISO 160, 4-hole Splined shaft 50x2x30x24x9g A4VSO/G 180 K34ISO 224, 4-hole Splined shaft 60x2x30x28x9g A4VSO/H/G 250 K35ISO 224, 4-hole Splined shaft 70x3x30x22x9g A4VSO/G 355 K77ISO 315, 8-hole Splined shaft 80x3x30x25x9g A4VSO/G 500 K43ISO 400, 8-hole Splined shaft 90x3x30x28x9g A4VSO/G 750 K76ISO 400, 8-hole Splined shaft 100x3x30x32x9g A4VSO/G 1000 K88ISO 80, 2-hole Splined shaft 3/4" 19-4 (SAE A-B) A10VSO 18 KB2ISO 100, 2-hole Splined shaft 7/8" 22-4 (SAE B) A10VSO 28 KB3ISO 100, 2-hole Splined shaft 1" 25-4 (SAE B-B) A10VSO 45 KB4ISO 125, 2-hole Splined shaft 1 1/4" 32-4 (SAE C) A10VSO 71 KB5ISO 125, 2-hole Splined shaft 1 1/2" 38-4 (SAE C-C) A10VSO 100 KB6ISO 180, 4-hole Splined shaft 1 3/4" 44-4 (SAE D) A10VSO 140 KB782-2 (SAE A, 2-hole) Splined shaft 5/8" 16-4 (SAE A) G2 / GC2/GC3-1X K0182-2 (SAE A, 2-hole) Splined shaft 3/4" 19-4 (SAE A-B) A10VSO 18 K52101-2 (SAE B, 2-hole) Splined shaft 7/8" (SAE B) G3 K02101-2 (SAE B) Splined shaft 25-4 (SAE B-B) GC4-1X, A10VO 45 K04127-2 (SAE C) Splined shaft 32-4 (SAE C) A10VO 71 K07101-2 (SAE B) Splined shaft 32-4 (SAE C) GC5-1X K06127-2 (SAE C) Splined shaft 38-4 (SAE C-C) GC6-1X, A10VO 100 K24152-4 (SAE D) Splined shaft 44-4 (SAE D) A10VO 140 K17 63, metric 4-hole Keyed shaft 25 R4 K57101-2 (SAE B) Splined shaft 22-4(SAE B) G4, A10VO 28 K68With through drive shaft, without hub, without adapter flange, with cover plate K99
Filtration (only with HS and DS control)Without filter NSandwich plate filter (with HS and DS control see RE 92076 and RE 92055) Z
Series
Seals
Shaft end
Direction of rotation
Control device
Axial piston unit
Boost pump
Nominal size
Type of operation
Combination pumps1. If a second Brueninghaus pump is to be fitted in the factory, then both type codes should be joined with "+".
Type code 1st pump + type code 2nd pumpOrdering example: A4VSO 125 DR/22R PPB13K33 + A4VSO 71 DR/10R PZB13N00.
2. If a gear or radial piston pump is to be fitted in the factory, please consult us.
Hydraulic fluid / version
A4VS O /
Mounting flange
4/40 Bosch Rexroth AG | Mobile Hydraulics A4VSO | RE 92 050/09.97
t min = - 25 C Druckflssigkeitstemperaturbereich t max = + 90 C
- 25 - 10 10
20
30 50 70 90
- 20 0 40 60 80 1001000
36
16
Temperaturt ( C)
10
1000600400
200
1008060
40
20
15
10
Visk
osit
t (m
m2
/ s)
op
t
VG 22
VG 32
VG 46VG 68VG 100
Hydraulic fluidFor extensive information on the selection of hydraulic fluids andfor application conditions, please consult our data sheet RE90220 (mineral oils), RE 90221 (ecologically acceptablepressure fluids) and RE 90223 (HF pressure fluids). Whenoperating with ecologically acceptable and HF fluids limitationsto the technical data may be necessary.
Operating viscosity rangeIn order to obtain optimum efficiency and service life, werecommend that the operating viscosity (at operatingtemperture) be selected in the range
opt = optimum operating viscosity 16...36 mm2/s
referred to tank temperature (open circuit).
Limit of viscosity rangeFor critical operating conditions the following values apply:min = 10 mm
2/sfor short periods at max. permissible leakage oiltemperature 90 C.
max = 1000 mm2/s
for short periods on cold start.
Comments on the selection of the hydraulic fluidIn order to select the correct fluid, it is necessary to know theoperating temperature in the tank (open circuit), in relation to theambient temperature.The hydraulic fluid should be selected such that, within theoperating temperature range, the operating viscosity lies withinthe optimum range (opt), see shaded section of selection dia-gram. We recommend that the higher viscosity grade is selectedin each case.
Selection diagram
Determination of displacementVg n v
Flow qv = [L/min] 1000
1,59 Vg pDrive torque T = [Nm]
100 mh
2 T n T n qv pDrive power P = = = [kW] 60000 9549 600 t
Vg = Geometric displacement [cm3]
per revolution p = Pressure differential [bar]n = Speed [RPM]v = Volumetric efficiencymh = Mechanical/hydraulic efficiencyt = Overall efficiency (t = v mh)
Example: At an ambient temperature of X C, the operatingtemperature in the tank is 60 C. Within the operating viscosityrange (opt; shaded area), this corresponds to viscosity range VG46 or VG 68. VG 68 should be selected.Important: The leakage oil (case drain oil) temperature isinfluenced by pressure and pump speed and is always higherthan the tank temperature. However, at no point in the circuit maythe temperature exceed 90 C.
Notes regarding series 30When using external bearing flushing at port U the throttle screw,which is to be found at port U, has to be sc