8
Valve Integrated Pressure Regulator

Valve Integrated Pressure Regulator - Cramer Decker€¦ · products for multiple compressed gas markets, ... Harrison Valve is a global supplier of precision ... Valve Integrated

Embed Size (px)

Citation preview

Page 1: Valve Integrated Pressure Regulator - Cramer Decker€¦ · products for multiple compressed gas markets, ... Harrison Valve is a global supplier of precision ... Valve Integrated

Valve Integrated Pressure Regulator

Page 2: Valve Integrated Pressure Regulator - Cramer Decker€¦ · products for multiple compressed gas markets, ... Harrison Valve is a global supplier of precision ... Valve Integrated

The OMNIValve offers medical customers a single solution for oxygen delivery to patients ending the necessity for stocking both oxygen cylinders and regulator devices throughout their facilities, and ending the additional labor of monitoring empty and full cylinders, and attaching regulators to cylinders. Most important, the OMNIValve provides medical technicians a simple-to-operate device with straight forward remaining oxygen contents gauge minimiz-ing the risk to have an empty cylinder when time is critical during emergencies.

Harrison designed the most common OMNIValve with a solid brass, chrome plated one piece construction that delivers customers a very durable all-in-one oxygen delivery system for years of service life. The OMNI Valve is available in many configurations to service all medical facilities including medical offices, hospitals and EMS. Special order anodized aluminum units are available with custom engraving for private label applications.

Harrison Valve™ has longstanding experience in designing and manufacturing products for multiple compressed gas markets, critical applications and OEM customers, and its operations focus exclusively on producing the highest quality valve products at uncompromised value. Harrison Valve™ products are produced to meet or exceed the highest US and international standards.

Harrison Valve is a global supplier of precision

valve products serving a broad range of applications, industries and markets. Harrison Valve manufactur-

ers a full line of high pressure cylinder valves including industrial, medical, residual pressure, acetylene and

specialty products. Harrison Valve is the fastest growing cylinder valve manufacturer in the world today.

Emergency Services

Hospitals

Outpatient Medical Facilities

www.HarrisonValve.com • 877-598-6657

Valve Integrated Pressure Regulator

Medical Offices

Page 3: Valve Integrated Pressure Regulator - Cramer Decker€¦ · products for multiple compressed gas markets, ... Harrison Valve is a global supplier of precision ... Valve Integrated

Easy-to-read cylinder contents gauge in rubber boot and enclosed guard

Positive click liter flow dial

Easy to carry valve protection carry handle

Chrome plated oxygen delivery cannula

Solid brass one-piece design (Anodized aluminum is available special order)

High luster, chrome plated finish for cleanliness

50PSI constant flow DISS outlet

Special order custom logo and anodizedcolor choices on aluminum models

CGA540 fill port with check valve, no shut off valve is required

OMNI Valve exceeds CGA E-18 standards. All regulators pass ASTM G175 ignition tests.

Dual purpose protective CGA540 fill port dust cap attaches to DISS outlet for easy purging

OMNIValve is available for aluminum and steel cylinders

www.HarrisonValve.com • 877-598-6657

OMNIValveOutstanding Features

• OMNIValve is manufactured in FDA registered manufacturing facilities. • All processes and procedures are followed to the ISO9001:2000 standards.• Precision machining tolerances deliver the most accurate performance and reliability.• User can initiate flow with a simple turn of the positive click liter flow dial. OMNIValve liter per minute flow is top of class at +/- 10% accuracy by independent testing laboratories.• High quality chrome plated, solid brass construction for superior strength and durability. Special order anodized aluminum models are available.• All OMNI Valves exceed CGA E-18 standards. All regulators pass the ASTM G175 ignition tests.• Ergonomically designed carry handle simplifies lifting and cylinder handling, meets drop tests, and protects the regulator body and gauge from damage.• All models are supplied with a barb and 50PSI constant flow DISS outlet.• The check valve fill port is pressure operated with standard soft tip CGA540 hand tight filling adaptor. Purging, evacuation and fill is accomplished with the single connection.• All units are serial numbered for traceability.• Private label options.

Standard Liter Flow AvailableLiter Per Minute Positive Click Settings Typical Application25 LPM 0, 1/4, 1/2, 1, 2, 3, 4, 6, 8, 10, 15, 25 EMS, Hospital15 LPM 0, 1/4, 1/2, 1, 2, 3, 4, 6, 8, 10, 12, 15 Hospital, Homecare4 LPM 0, 1/32, 1/16, 1/8, 1/4, 1/2, 3/4, 1, 1 1/2, 2, 3, 4 Pediatric

SpecificationsMaximum Working Pressure: 3000PSIStandard Operating Pressure: 2015PSIStandard Safety Device: 3360PSI, CG4, 165F fusible metalDimensions: 6”H x 4”W x 3.75”DOperating Temperature: -13-140FBrass Model Weight: 2lbs 6ozAluminum Model Weight: 2lbs

Page 4: Valve Integrated Pressure Regulator - Cramer Decker€¦ · products for multiple compressed gas markets, ... Harrison Valve is a global supplier of precision ... Valve Integrated

Part Number Body Material Inlet Fill Port DISS Liter Per Minute

Part Number Body Material Inlet Fill Port DISS Liter Per Minute

OMNI-3-4-3360-25 Chrome plated brass .750-16UNF2A CGA540 Yes 25LPMOMNI-3-4-3360-15 Chrome plated brass .750-16UNF2A CGA540 Yes 15LPMOMNI-3-4-3360-4 Chrome plated brass .750-16UNF2A CGA540 Yes 4LPM

OMNI-4-4-3360-25 Chrome plated brass ½” NGT CGA540 Yes 25LPMOMNI-4-4-3360-15 Chrome plated brass ½”NGT CGA540 Yes 15LPMOMNI-4-4-3360-4 Chrome plated brass ½” NGT CGA540 Yes 4LPM

OMNI Valve for Aluminum Cylinders

OMNI Valve for Steel Cylinders

www.HarrisonValve.com • 877-598-6657

Chrome PlatedBrass Body

The OMNIValve by Harrison Precision Valve Products, is a revo-lutionary and compact integrated medical valve and regulator (All-In-One) system designed for all medical applications. The OMNIValve, like all Harrison products, exceeds the highest inter-national standards for performance and reliability.

The standard OMNIValve is designed from a solid brass one piece construction offering the most durable product to the market.

www.HarrisonValve.com • 877-598-6657

Page 5: Valve Integrated Pressure Regulator - Cramer Decker€¦ · products for multiple compressed gas markets, ... Harrison Valve is a global supplier of precision ... Valve Integrated

Part Number Body Material Inlet Fill Port DISS Liter Per Minute

Part Number Body Material Inlet Fill Port DISS Liter Per Minute

OMNI-AL-3-4-3360-25 Anodized aluminum .750-16UNF2A CGA540 Yes 25LPMOMNI-AL-3-4-3360-15 Anodized aluminum .750-16UNF2A CGA540 Yes 15LPMOMNI-AL-3-4-3360-4 Anodized aluminum .750-16UNF2A CGA540 Yes 4LPM

OMNI-AL-4-4-3360-25 Anodized aluminum ½”NGT CGA540 Yes 25LPMOMNI-AL-4-4-3360-15 Anodized aluminum ½” NGT CGA540 Yes 15LPMOMNI-AL-4-4-3360-4 Anodized aluminum ½” NGT CGA540 Yes 4LPM

www.HarrisonValve.com • 877-598-6657

OMNI Valve for Aluminum Cylinders

OMNI Valve for Steel Cylinders

AnodizedAluminum Body

The OMNIValve by Harrison Precision Valve Products, is a revolutionary and compact integrated medical valve and regulator (All-In-One) system designed for all medical applications. The OMNIValve, like all Harrison products, exceeds the highest international standards for performance and reliability.

For customers requiring custom colors and logos, the OMNIValve is available special order with an aluminum sleeve over brass internal core to allow eye catching anodizing and laser engraving.

www.HarrisonValve.com • 877-598-6657

Page 6: Valve Integrated Pressure Regulator - Cramer Decker€¦ · products for multiple compressed gas markets, ... Harrison Valve is a global supplier of precision ... Valve Integrated

M6 M9 D Jumbo D E

Complete OMNI Cylinder Systems

www.HarrisonValve.com • 877-598-6657

Cylinder

144

6

170

2216

153

11.59

294

3.2

81

2.2

1

81

9

255

2015

139

11.88

276

4.38

111

3.7

1.69

81

15

425

2015

139

16.51

419

4.38

111

5.3

2.41

72

22.6

623

2015

139

16.3

414

5.25

133

8.1

3.68

81

24

680

2015

153

25.63

651

4.38

111

7.9

3.58

Skid Quantity

Oxygen CapacityC.U.F.T

PSI

BAR

INCHES

INCHES

MM

MM

LBS

KG

LITER

Service PSI

Cylinder Length

Cylinder O.D.

Cylinder Weight

* For systems with 4 or 15LPM, replace the 25 to the appropriate liter flow.

Model Number Description

OMNI-540E-25LPM OMNIValve E cylinder system, 25LPMOMNI-540JD-25LPM OMNIValve JD cylinder system, 25LPMOMNI-540D-25LPM OMNIValve D cylinder system, 25LPMOMNI-540M9-25LPM OMNIValve M9 cylinder system, 25LPM OMNI-540M6-25LPM OMNIValve M6 cylinder system, 25LPM

Chrome Plated Brass OMNIValve Aluminum Cylinder Systems

The OMNIValve is available with a wide selection of aluminum medical cylinders. Aluminum cylinders are the cylinder of choice in the medical industry due to their clean finish and lightweight characteristics.

Page 7: Valve Integrated Pressure Regulator - Cramer Decker€¦ · products for multiple compressed gas markets, ... Harrison Valve is a global supplier of precision ... Valve Integrated

Instructions

www.HarrisonValve.com • 877-598-6657

WARNINGS

Installation to a high pressurealuminum cylinder

Refilling the cylinder equipped with an OMNI Valve

Purging

Vacuum and filling

Overview

Use

• This device should be used by qualified medical technicians only.• This unit should only be used on patients who are breathing; do not use to resuscitate non-breathing patients.• Do not use with oil, grease or any other flammable materials.• Keep out of reach of children.• Do not smoke in an area where oxygen is in use.• Do not use this equipment unless you have been trained in its proper use or are under the supervision of someone trained in its use.• If the pressure relief valve on the body of the regulator begins to vent oxygen, turn off the system and remove the unit from service until it can be serviced by trained personnel.

The OMNI Valve (Integrated Medical Valve and Regulator) is a cylinder mounted flow control regulator and cylinder valve combination designed to deliver oxygen at safe operating levels. Oxygen flow control regulators are intended for the administra-tion of oxygen to patients who need to improve their breathing conditions. Some models can also be used in emergency situa-tions. In an emergency situation, always contact a physician or Emergency Medical Services immediately.

The OMNI Valve must be stored with the flow control knob in the “OFF” position to cease any oxygen flow. Turn the flow control knob counter clockwise until the knob reads “OFF”.

Adjust the flow setting by turning the flow control knob clock-wise until the desired setting (LPM – Liter Per Minute) shows through the selection window. The standard flow settings for the 0-25LPM model include 12 click positions. The positions are OFF, ½, 1, 2, 3, 4, 5, 6, 8, 10, 15, 25.

When the operating pressure of the cylinder falls below 300PSI, it is recommended to exchange the cylinder as soon as possible for a full pressurized cylinder.

Turn off the system, turn the flow control knob counter clock-wise, or to the left, until the “OFF” position shows through the selection window.

Before installing the OMNI Valve onto a cylinder, be sure the cylinder is free of any debris and is cleaned for medical oxygen service. Inspect the cylinder and OMNI valve connection threads for debris and damage. If any thread damage is visible, put the cylinder or OMNI valve aside until they can be serviced by a qualified service center.

Inspect the white Teflon cylinder valve seal (which is provided with a new unit) and be sure it is placed on the threads at the base of the OMNI valve in the proper seated location. Hand tighten the OMNI valve into the cylinder carefully to prevent cross threading. The OMNI valve should thread easily to the cylinder without binding.

An oxygen cylinder should be secured with a proper cylinder vice. A torque wrench set at 65-70 foot pounds is required to achieve a proper and safe installation of the OMNI valve to an aluminum cylinder. Do not wrench any location of the OMNI valve regulator body other than the designated 1-1/8” wrench flat at the base of the OMNI valve. OMNI valves attempted to be installed in any other manner can damage the Omni Valve and void the warranty.

Proceed to filling the OMNI valve after installation. Be sure to check for leaks as a matter of standard filling practice as recom-mended by the FDA and CGA.

IMPORTANT: Before filling or refilling a cylinder with medical oxygen, the cylinder must be emptied of all oxygen. FDA regu-lations require the evacuation of the oxygen cylinder prior to refilling with new oxygen.

To avoid damaging the CGA540 Fill Port, the OMNI valve is equipped with a protective cap which serves a dual purpose, 1) To protect the CGA540 fill port from damage while not in use, storage or transport, and 2) to be screwed onto the DISS Outlet port in order to purge the cylinder from any residual oxygen, or in the event the tank must be emptied immediately.

To purge the cylinder of any remaining residual oxygen, remove the CGA540 protective fill cap from the CGA540 filling port and at-tach it to the DISS outlet constant flow outlet. In conjunction, set the regulator to the highest flow setting of 25LPM. This process will empty the contents of the OMNI Valve system to ambient pressure by purging the gas through the DISS outlet and flowing oxygen through the regulator barb. Once the cylinder reaches ambient pressure, remove the CGA540 protective fill cap from the DISS outlet and set the regulator back to the “OFF” position.

You may now continue the evacuation and fill process by connect-ing the CGA540 filling adaptor to the fill port. Make sure all fittings are tight before vacuum or pressure supply valves are opened. The OMNI Valve is equipped with an internal, one way, self opening valve that will allow the filling of the cylinder, and will automatical-ly shut off during the disconnection of the fill adaptor / fill hose.

NOTE: It is normal for there to be some venting of trapped oxygen during the disconnection of the fill hose. This venting should stop within the first half of a turn of the CGA540 nut. If there is contin-ued leakage from the fill fitting following disconnection, the unit may be damaged and require service.

SPECIAL NOTES:

NEVER try to repair, disassemble, or modify this unit in any capacity. All repairs should be made by qualified and approved regulator technicians. Please consult your dealer, distributor, and/or physician with any questions or concerns that are not covered by this instruction manual.

This unit is not designed to be MRI compatible.

Page 8: Valve Integrated Pressure Regulator - Cramer Decker€¦ · products for multiple compressed gas markets, ... Harrison Valve is a global supplier of precision ... Valve Integrated

1641 E. St. Andrews Place,

Santa Ana CA 92705

877.598.6657

www.harrisonvalve.com