Validation of DTI Analysis. Guido Gerig, Clement Vachet, Isabelle Corouge, Casey Goodlett UNC Chapel Hill. Validation Concepts. Validity: Comparison to truth / gold standard Reliability, Reproducibility: Repeated measures Outcome measures: Sufficient to answer clinical question. - PowerPoint PPT Presentation

Citation preview

Page 1: Validation of DTI Analysis

NA-MICNational Alliance for Medical Image Computing http://na-mic.org

Validation of DTI Analysis

Guido Gerig, Clement Vachet, Isabelle Corouge, Casey Goodlett

UNC Chapel Hill

Page 2: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Validation Concepts

• Validity: Comparison to truth / gold standard

• Reliability, Reproducibility: Repeated measures

• Outcome measures: Sufficient to answer clinical question

Page 3: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Validation: DTI Image Analysis

• Validity:– In vivo human imaging: Truth not known– Ex vivo pathological samples: tissue dynamics not

preserved– Animal imaging:

• Hi-res DT-MRI with animal scanner• Possibility to induce pathology: lesions, de-myelination

• Goldish or Silver Standard: Phantom– Nylon fibers embedded in water, interweaved to

simulate crossings: Far from simulation of axons and myelination sheaths

– Computational phantom: Simulated diffusion imaging?– Others?

Page 4: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Validation: DTI Image Analysis

• Reliability, reproducibility:– Reproducibility of scanning: Repeated scans single or

multi-site– Reproducibility of image analysis and/or individual steps

• Key Problems:– Metric to determine differences– Imaging and image analysis come with large set of

parameters– Validation of single processing steps versus validation

of whole system– Relation of validation metric to clinical question and

group findings

Page 5: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Very preliminary attempts

• Repeatability of quantitative tractography-based FA/MD (ISMRM 2005)

• Tool for geometric fidelity of fiber tract ROI (Casey Goodlett)

Page 6: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Validation: Fiber Tracking

• Goal: Evaluate the reproducibility of quantitative tractography (FiberViewer)

• Study: – 6 scans of the same patient with small motion

(MacFall, Duke)– 3 callosal fiber tracts

• Method: – Fiber Extraction

• Selection of a ROI on one scan• Registration for the 5 other scans• Tracking of Fibers

– Analysis across the 6 scans• Diffusion properties: FA, ADC, λ1, λ2, λ3

6 repeated scans DTI average

Page 7: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Validation: 6 repeated scans

Scan1

Scan2…

T B01B02

… Scan6

DTI Average

T B01B06

Extraction

Extraction

Extraction

Scan 2…

…Scan 6

DTI Average

Selection of a ROI

Registration of ROI

Page 8: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Scans' Comparison: Number of Fibers (ROI:essai3-th69)

0

20

40

60

80

100

120

140

160

180

Dif 1 Dif 2 Dif 3 Dif 4 Dif 5 Dif 6 Average

Nu

mb

er

of

Fib

ers

Number of “Fibers” (streamlines): Really not meaningful

DTI Average

The fallacy of #”fibers”

Page 9: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Tract-based diffusion propertiesScans' Comparison: FA (ROI: essai3-th69)

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

Points

FA

Mean Mean+std Mean-std

Scans' Comparison: ADC (ROI: essai3-th69)

0

2

4

6

8

10

12

14

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

Points

AD

C

Mean Mean+std Mean-std

Statistics across 6 repeated scans:

Curves of MeanFA and MeanMD, with Standard Deviation

FA

FA

MD

Page 10: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Tract-based diffusion propertiesStatistics across 6 repeated scans: eigenvalues

1Scans' Comparison: Lambda2 (ROI: essai3-th69)

0

2

4

6

8

10

12

14

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

Points

La

mb

da

2

Mean Mean+std Mean-std

Scans' Comparison:Lambda3 (ROI: essai3-th69)

0

2

4

6

8

10

12

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

Points

Lam

bda2

Mean Mean+std Mean-std

Scans' Comparison: Lambda1 (ROI: essai3-th69)

0

5

10

15

20

25

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

Points

Lam

bda1

Mean Mean+std Mean-std

2 3

Page 11: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Tract-based diffusion properties

FA

Scans' Comparison: FA (ROI: essai3-th69)

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

Points

FA

Mean-FA DTIAverage-FA

Scans' Comparison: ADC (ROI: essai3-th69)

0

2

4

6

8

10

12

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

Points

AD

C

MeanADC DTIAverage-ADC

FA

MD

Curves of MeanFA and MeanMD in comparison to the Average DTI

Page 12: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Scans' Comparison: Lambda1 (ROI: essai3-th69)

0

2

4

6

8

10

12

14

16

18

20

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

Points

Lam

bd

a1

Mean-Lambda1 DTIAverage-Lambda1

Scans' Comparison: Lambda2 (ROI: essai3-th69)

0

2

4

6

8

10

12

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

Points

Lam

bda2

Mean-Lambda2 DTIAverage-Lambda2

λ1

λ2

λ3

Scans' Comparison:Lambda3 (ROI: essai3-th69)

0

1

2

3

4

5

6

7

8

9

10

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

Points

Lam

bda2

Mean-Lambda3 DTIAverage-Lambda3

Tract-based diffusion properties

Curves of mean eigenvalues in comparison to the eigenvalues of the average DTI

Page 13: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Quantitative Results

Table: Results at the center, i.e. at the position of the midsagittal plane, are listed. The second row lists the number of streamlines obtained for each experiment. Although the number of streamlines varies due to the instability of tractography, the resulting diffusion tensor statistics are approximately within 5%std for FA and MD but only 2%std for the first eigenvalue λ1. The FA of the DTI average (last column) is slightly lower than the 6 case mean.

Guido Gerig , Isabelle Corouge, Clement Vachet, Ranga Krishnan and James MacFall, Quantitative Analysis of Diffusion Properties of White Matter Fiber Tracts: A Validation Study, International Society of Magnetic Resonance ISMRM, May 2005 (peer reviewed long abstract)

Page 14: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Geometric reproducibility of tracts

• How to compare geometry tractography results

• Proposed method (BIRN): Map tractography result to binary voxel map, binary overlap test (Dice, kappa stats))– very low enthusiasm

• Brainstorming with Casey Goodlett:– Streamline tracking unstable, ill-posed– Key question: Correspondence?

Page 15: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Work in progress

• Distance measure between sets of bundles

• Give up on point-to-point correspondence between streamlines

• Solution/Tool: Measure geometric distance of points in bundle A to closest point in bundle B

• Measure is non-symmetric

Page 16: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Validation: Tract Comparison

Comparison of scan 1 with original and modified tracking method

Page 17: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Validation: Tract Comparison

Comparison of scan 1 with scan 4

Page 18: Validation of DTI Analysis

National Alliance for Medical Image Computing http://na-mic.org

Conclusions

• NAMIC could develop concept, strategy and tools for validation of DTI

• Validation of reproducibility of diffusion properties (tensor stats)

• Validation of geometry of extracted bundles: Metric for bundle distance

• ….