56
Precision Sampling Catalog (800) 828-1653 CATALOG 06 ®

Valco Cheminert - VICI - Resolution Systems

Embed Size (px)

DESCRIPTION

Valco Cheminert - VICI - Resolution Systems

Citation preview

Page 1: Valco Cheminert - VICI - Resolution Systems

PrecisionSampling

Catalog

(800) 828-1653

CATALOG 06

®

Page 2: Valco Cheminert - VICI - Resolution Systems

ContentsContentsContentsContentsContents

SYRINGE FEATURESPressure-Lok® syringe features ............... page 2Special features of select models ..................... 3Gas/liquid and liquid syringe features ......... 4-5

GAS/LIQUID SYRINGESSeries A ...................................................................... 6

Pressurized sample storage with built-inTwist-Lock valve

Series A-2 .................................................................. 7Pressurized sample storage with built-inpush-button valve

Series C ...................................................................... 8With optional Chaney adapter

Series D ...................................................................... 9Without built-in valve

Mininert syringe valves ......................................... 9Add storage capability to C & D syringes

Magnum .................................................................. 10Pressurized storage for trace sampleisolation

Replacement needles ........................................ 11Replacement components ......................... 12-13

LIQUID SYRINGESSeries C-160 .......................................................... 14

Basic PTFE plunger tipped microsyringeSeries C-120 .......................................................... 15

Barrel extension for attaching a vacuumbulb or line

Series CG-130 ....................................................... 16Reinforced plunger to prevent bending

Series CGV-130 .................................................... 17Adds a side vent for filling and cleaning

Series D-140 .......................................................... 18For small volume (1 - 10 µl) injections

Mini-injector .......................................................... 19For reproducible injections down to .01 µl

HPLC syringes ................................................. 20-21Designs for most injectors

Purge and trap ...................................................... 22Premium syringe for environmentalapplications

Replacement needles and componentsfor liquid syringes ................................................ 23

AUTOSAMPLER AND OEM SYRINGESVarian .......................................................... page 24Perkin Elmer .......................................................... 25Central Instruments ............................................ 25

HIGH PRESSURE SYRINGESPressure-Flo® ......................................................... 26

High pressure syringe for cylinder samplingMicro-Flo® ............................................................... 27

For samples up to 500 psiReplacement componentsfor high pressure syringes ................................ 27

MININERT™ VALVESGeneral description ........................................... 28Specifications ........................................................ 28Valves for vials ...................................................... 28

Leak-tight closures for screw-cap vialsValves with standard tapers ............................. 29

Fits standard laboratory glasswareValves with threaded fittings........................... 29

Male and female NPT and 1/4-28Replacement parts and accessories .............. 29

Septa, tools, needle guidesValves for syringes ............................................... 29

Add storage capability to a conventionalsyringe

PROBESCentral Instruments ............................................ 30PTA-30, WS, and DynaTrap Instruments ....... 31Varian Archon Instruments ............................... 31

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected] .com

Page 3: Valco Cheminert - VICI - Resolution Systems

1

ContentsContentsContentsContentsContents

www.vici.com

TUBINGMetal tubing

Pre-cut lengths ............................ page 32-33Custom lengths ............................................ 34

PEEK tubing (striped color coded) ................. 35Polymeric tubing

Custom lengths ............................................ 34Polymer tubing cutters

Clean Cut ........................................................ 36Guillotine ......................................................... 36

Tubing accessoriesEasy-Flange kits ............................................. 37PEEK tubing elbows ..................................... 36Tubing Clip LC tubing organizer .............. 36

SAMPLE LOOPSFor Valco valves .............................................. 38-39For Cheminert® valves .................................. 38-39For Rheodyne® valves ................................... 38-39

FITTINGSCheminert low pressure fittings

Flangeless tube end fittings ..................... 40Flanged tube end fittings .......................... 41

Flanging tool ........................................... 41Plugs ................................................................. 42Tees ................................................................... 42Crosses ............................................................. 42Unions .............................................................. 43Bulkhead unions ........................................... 43Luer adapters ................................................. 43

Cheminert high pressure fittingsNuts and ferrules .......................................... 44Plugs ................................................................. 44

Jour fittingsPPS one-piece hex head ............................ 45Color-Sleeve fingertight adapters .......... 46PEEK one-piece fingertight ...................... 46

AUTOMATED LIQUID HANDLINGMicro valve for GC and LC NEW ......... page 47Hollow plunger syringe NEW ......................... 48Syringes for diluter/dispensers and

automated instrumentation NEW ......... 48

SUPPORTProduct number index ..................... page 49-51Ordering information ......................................... 52Trademark information ......... Inside back cover

Page 4: Valco Cheminert - VICI - Resolution Systems

2

Syringe FeaturesSyringe FeaturesSyringe FeaturesSyringe FeaturesSyringe Features

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Pressure-Lok® Syringe Features

Pressure-Lok® Syringe FeaturesPTFE Plunger Tip

Plunger tips are fabricated of PTFE, stress-formed by our ownspecial process to insure a leak-tight seal. The self-lubricating plunger tip stays smooth for the life of thesyringe, with none of the freezing up or residue build-upassociated with conventional all-metal plungers.

PTFE-Sealed Needle

Standard needle attachment includes a barrier sleeve orpacking of PTFE on the rear of the needle at the zero point.This isolates the sample from the needle cement, preventingpossible dissolution of the adhesive or contamination of thesample. Many models are also available in a luer-tip version.

Ultra-Smooth Bore

Syringe barrels up to 100 µl are hand-fabricated from high quality borosilicateglass, manufactured to our specifications. The extremely smooth bore preventsundue wear of the plunger tip and insures a smooth, durable seal.

Hand Calibration

Each barrel undergoes a series of quality checks, including hand-calibrationof consistent volume delivery. After final assembly of each lot, volumedelivery is checked again with an electronic microbalance. These carefulsteps in quality control insure that every Pressure-Lok® microsyringemeasures up to today’s stringent requirements for precision and accuracy.

Easily Replaceable Parts

Depending on the specific model, some or all of the wear parts can be easilyreplaced, optimizing your equipment investment.

Shaped Rear Flange

All syringes have a rear flange to provide a secure grip and keep the syringe fromrolling.

Low Dead Volume

Every syringe design takes advantage of every opportunity to minimize oreliminate dead volume.

Crisp, Clean Graduations

Our methods insure easy reading of the sampled amount.SAFETY NOTE

To prevent possibleinjury, proper safetyprecautions shouldalways be observedwhen pressurizing glasscylinders such assyringes.

PTFE

Polytetrafluoroethylene isthe generic name for theclass of materials such asTeflon® sold by E.I. duPontde Nemours.

Page 5: Valco Cheminert - VICI - Resolution Systems

3

Syringe FeaturesSyringe FeaturesSyringe FeaturesSyringe FeaturesSyringe Features

www.vici.com

Special Features

Special Features of Select ModelsPressurized Sample Storage

Several of our syringes have a built-in valve to allow sample storage at up to250 psi. This feature also allows pre-pressurization of the sample before injectionso that the sample is flushed into the column instantaneously, providing betterresolution. For conventional syringes, our Mininert syringe valve adds this capacity.

Removable Needles

Many models offer a special pressure-tight, low dead volume connection tofacilitate easy removal and replacement of needles.

Optional Luer Tip for Convenience

Although our standard PTFE-sealed needle offers superior performance, wealso offer the added convenience of luer-tip models.

Positive Rear Plunger Stop

If plunger damage from accidental plunger removal has been a problem,select one of our syringes with this feature.

Reinforced Plunger

If plunger-bending is a problem that contributes to excessive syringe repairbills in your lab, this feature offers a solution.

Side Vent

VICI Precision Sampling offers a unique model with a side vent, allowing easysyringe filling and cleaning.

PRODUCTS WITHTHESE FEATURES

Pressurized SampleStorageGas ................ pages 6 -7, 10High pressure ........ 26 - 27

Removable NeedlesGas ................................. 6 -10Liquid ................... 14, 16, 18

Optional Luer TipGas ................................ 7 -10Liquid .................................. 22

Positive Rear PlungerStopGas ............................ 6 - 8,10Liquid .......................... 18, 19High pressure ........ 26 - 27

Reinforced PlungerLiquid .......................... 16 -19

Side VentLiquid .................................. 17

SAFETY NOTE

To prevent possibleinjury, proper safetyprecautions shouldalways be observedwhen pressurizing glasscylinders such assyringes.

Custom ProductsAt VICI Precision Sampling, we take great pride in being able to customize ourproducts to fit your needs while maintaining our standards. Call us if you needcustom length needles, special gauge needles, or custom syringes.

Page 6: Valco Cheminert - VICI - Resolution Systems

4

Syringe FeaturesSyringe FeaturesSyringe FeaturesSyringe FeaturesSyringe Features

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Syringe Features

PRESSURE-LOK®SYRINGE FEATURES

PTFE plunger tipPTFE-sealed needleUltra-smooth boreHand calibrationEasily replaceable partsShaped rear flangeLow dead volumeCrisp, clean graduations

Syringe FeaturesVICI Precision Sampling syringes have all the standard features noted belowat left, with special features delineated in the charts below.

FEATURES Pressure Removable Luer Sample-Lok Plunger Pagerating needle needle valve type stop

Series A 250 psi twist-lock 6

Series A-2 250 psi push-button 7

Series C 250 psi * 8

Series D 250 psi * 9

Magnum 30 psi twist-lock 10

SAMPLE 25 50 100 250 500 1 2 5 10 20 50 100 250 500SIZES µl µl µl µl µl ml ml ml ml ml ml ml ml ml

Series A

Series A-2

Series C

Series D

Magnum

Gas/Liquid Syringes

* Order a Mininert syringevalve on page 9.

Page 7: Valco Cheminert - VICI - Resolution Systems

5

Syringe FeaturesSyringe FeaturesSyringe FeaturesSyringe FeaturesSyringe Features

www.vici.com

Syringe Features

FEATURES Pressure Removable Fixed Reinforced Plunger Side Pagerating needle needle plunger stop vent

Series C-160 250 psi 14

Series C-120 250 psi 15

Series CG-130 250 psi 16

Series CGV-130 250 psi 17

Series D-140 30 psi 18

Mini injector 19

Purge and trap 250 psi Luer lock 22

SAMPLE .01 .10 1 2 5 10 25 50 100 5 10SIZES µl µl µl µl µl µl µl µl µl ml ml

Series C-160

Series C-120

Series CG-130

Series CGV-130

Series D-140

Mini injector

Purge and trap

Liquid Syringes

Page 8: Valco Cheminert - VICI - Resolution Systems

6

Gas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Series A Pressure-Lok®

Series AIntegral sample storage valve

Actuated by turning the nosepiece

Positive rear flange plunger stopPrevents plunger from blowing out of barrel atelevated pressure

Modular constructionAll components may be quickly disassembled foreasy cleaning or replacement

Leak-tight to 250 psiLiquids and gases

Turn the nosepiece counterclockwise two turns and thevalve is closed. Insert the needle through the septum,then start pushing the plunger as you turn the nosepiececlockwise. Carrier backflushing is eliminated, resulting insharper peaks and better separations. When the plungeris fully depressed, the plunger face comes into firm, flushcontact with the bottom of the front packing, forcingessentially all of the sample out – there is virtually nocompressible dead volume remaining. The very smallinternal diameter of the needle also contributes to thedead volume minimization.

In addition to the characteristics which make it unique,the Series A gas syringe has all the standard Pressure-Lok® features such as a PTFE plunger tip, PTFE-sealedneedle, and ultrasmooth bore.

Series A syringes

StandardSamplesize Prod No Price

100 µl 010025 $ 6 8250 µl 010031 68500 µl 010032 72

1 ml 010033 722 ml 010034 72

5 ml 010035 7510 ml 010036 75

Replacement needles

Bevel, Side port,open end taper

Package of 3: Prod No Price Prod No Price

Standard Pressure-Lok®.029" x .012" x 2.25" 913050 $ 2 2 913052 $ 3 1

SPECSRemovable needlesBevel, open endRemovable needle size:

.028" x .012" x 2"250 psi max,

gases and liquids

NEEDLE TIPS

Bevel, open end

Side port, taper

Series A, 250 µl#010031

NOTE

Special replacementneedles are available onrequest.

Further reference

Replacementcomponents ..... page 12

Twist-Lock valveOpen (left) andclosed (right)

Page 9: Valco Cheminert - VICI - Resolution Systems

7

Gas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid Syringes

www.vici.com

Series A-2 Pressure-Lok®

Series A-2All the advantages of the Series A syringe plus:

Push-button valveAllows instantaneous injection

Smaller volumesGreat for small volatile samples

The A-2 features a push-button valve, which allowssample storage to 250 psi in syringes as small as 25 µl.This is useful with small liquid samples containing low-boiling components which would be lost throughevaporation using ordinary syringes.

The positive rear stop (in 250 µl and larger sizes)prevents plunger blowout at elevated pressures,protecting against sample loss or operator injury. Likethe Series A gas syringe, the A-2 has all the standardPressure-Lok® features such as a PTFE plunger tip, PTFE-sealed needle, and ultrasmooth bore. Replacementcomponents are available for easy repair.

Series A-2 syringes

Standard LuerSamplesize Prod No Price Prod No Price

25 µl 050023 $ 6 5 050043 $ 6 550 µl 050024 65 050044 65

100 µl 050025 68 050045 68

250 µl 050031 68 050051 68500 µl 050032 68 050052 68

1 ml 050033 70 050053 70

2 ml 050034 70 050054 705 ml 050035 74 050055 74

10 ml 050036 74 050056 74

Replacement needles

Bevel, Side port,open end taper

Package of 3: Prod No Price Prod No Price

Standard Pressure-Lok®.029" x .005" x 2" 943050 $ 2 2 – – – –.029" x .012" x 2" 943051 22 943052 $ 3 1

Luer.028" x .006" x 2" 943060 22 – – – –.028" x .012" x 2" 943061 22 943062 31

SPECSRemovable needlesBevel, open endNeedle size:

.029" x .005" x 2"(25, 50, and 100 µl)

.029" x .012" x 2"(all other sample sizes)

250 psi max,gases and liquids

Further reference

Replacementcomponents .. page 12

NEW hollow plungersyringe ................. page 48

Series A-2Standard, 25 µl

#050023

Series A-2Standard, 1 ml

#050033

Page 10: Valco Cheminert - VICI - Resolution Systems

8

Gas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Series C Pressure-Lok®

Series COptional Chaney adapter

Much lower dead volume than luer-style connectors

Perfect syringe for everyday useAll our standard features, but without a valve for pressurized samplestorage

Series C syringes

Standard Standard Luerw/ Chaney adapter

Samplesize Prod No Price Prod No Price Prod No Price

100 µl 030025 $ 4 5 101430 $109 030045 $ 4 5250 µl 030031 47 101440 1 0 9 030051 47500 µl 030032 47 101448 1 0 9 030052 47

1 ml 030033 47 101455 1 0 9 030053 472 ml 030034 50 101463 1 0 9 030054 50

5 ml 030035 51 101470 1 0 9 030055 5110 ml 030036 55 101478 1 0 9 030056 55

Replacement needles

Bevel, Side port,open end taper

Package of 3: Prod No Price Prod No Price

Standard Pressure-Lok®.029" x .005" x 2" 943050 $ 2 2 – – – –.029" x .012" x 2" 943051 22 – – – –

Chaney adapter.018" x .008" x .75" – – – – 101935 $ 5 5

SPECSRemovable needlesBevel, open endRemovable needle size:

.029" x .005" x 2"

.029" x .012" x 2"250 psi max,

gases and liquids

Series C,Standard needle

2 ml#030034

Series Cw/ Chaney adapter

2 ml#101463

NEEDLE TIPS

Bevel, open end

Side port, taper

Further reference

Replacementcomponents .. page 12

Page 11: Valco Cheminert - VICI - Resolution Systems

9

Gas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid Syringes

www.vici.com

Series D Pressure-Lok®

Series DAn economically priced high precision gas sampling syringe which offersmore features than conventional gas-tight designs:

Leak-tight, Pressure-Lok® plunger tip

No dead volume barrel design

Special low dead volume needle connector for accurate gas samples

Series D syringes

Standard LuerSamplesize Prod No Price Prod No Price

1 ml 040033 $44 040053 $442 ml 040034 44 040054 44

Replacement needles

Bevel, Side port,open end taper

Package of 3: Prod No Price Prod No Price

Standard Pressure-Lok®.029" x .012" x 2" 943051 $ 2 2 943052 $ 3 1

Luer.028" x .012" x 2" 943061 22 943062 31

SPECSRemovable needlesBevel, open endNeedle size:

.029" x .012" x 2"250 psi max,

gases and liquids

Further reference

Replacementcomponents .. page 12

Series DStandard, 1 ml

#040033

Mininert Syringe ValvesFor Series C and D syringes or conventional luer-tip syringes

Add sample storage capabilityMount a Mininert syringe valve on a standard syringe

Push button operationGreen to open, red to close

For a Series C or D syringe

These convenient add-on valves allow our Series C andD syringes to store samples at up to 250 psi. The valvebody is all PTFE, with a stainless steel stem.

Prod No Price

654050 $18

For a Luer-tip syringe

This model is identical to the valve above, except that itis designed to fit Luer-tip syringes from anymanufacturer and accept traditional Luer needles.

Prod No Price

654051 $19

Page 12: Valco Cheminert - VICI - Resolution Systems

10

Gas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Magnum SeriesBuilt-in twist-lock valve

Seals the sample (up to 30 psi) during transportationto the analysis site

Up to 500 ml capacityFor sampling low concentration levels

Positive rear plunger stopPrevents plunger from blowing out when contentsare pressurized

The detection of low levels of various environmentalcontaminants can require extraordinarily large samples.Magnum syringes facilitate the trapping of such samplesin remote locations. A built-in valve allows the sample tobe sealed within the syringe, maintaining sampleintegrity during transportation to the analysis site.

Magnums have been successfully used to sampleatmospheric contaminants such as sulfur dioxide andoxides of nitrogen at distant points of the earth. Thepositive displacement capability of the durable PTFEplunger seal permits use in a variety of subsequentprocedures involving extraction or concentration oftrace components. (With a cryogenic enrichmentapparatus, for example.)

The standard termination is a female threaded fitting(1/4-28), which accepts a variety of Cheminert® connectorsor adapters. Specially formed seals permit leak-tightoperation to 30 psi (approximately 2 atmospheres).Because of the obvious danger in overpressurizing any glasscontainer, the internal pressure of a Magnum gas syringeshould never exceed 2 atmospheres.

Magnum syringes

Standard LuerSamplesize Prod No Price Prod No Price

20 ml 060037 $342 060043 $34750 ml 060039 3 4 5 060044 3 5 0

100 ml 060040 3 9 5 060045 4 0 0250 ml 060041 5 3 0 060046 5 3 5500 ml 060042 5 8 5 060047 5 9 0

Replacement needles

Bevel, Side port,open end taper

Package of 3: Prod No Price Prod No Price

Standard Pressure-Lok®.035" x .023" x 2" 953050 $ 2 2 953052 $ 3 1

Luer.035" x .023" x 2" 953061 22 953062 31

SPECSRemovable needlesBevel, open endRemovable needle size:

.035" x .023" x 2"30 psi max,

gases and liquids

Magnum seriesStandard, 500 ml

#060042

Magnum Series

Further reference

Replacementcomponents .. page 13

Page 13: Valco Cheminert - VICI - Resolution Systems

11

Gas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid Syringes

www.vici.com

Replacement Needles

Replacement Needles for Gas/Liquid SyringesSlip-on needles for Series A-2, C, and D syringes feature a needle extensionthrough the hub that fits inside the PTFE tip on the syringe. This designeliminates the dead volume inherent in conventional hubbed needles.

Needles are manufactured to exacting tolerances from high precisionstainless steel tube stock. The point styles and lengths listed below arestandard, but we are willing to supply others. Let us know yourrequirements.

Replacement needles

Package of 3: Bevel, Side port,open end taper

Series Prod No Price Prod No Price

A Standard Pressure-Lok®.029" x .012" x 2.25" 913050 $ 2 2 913052 $ 3 1

A-2 Standard Pressure-Lok®.029" x .005" x 2" 943050 22 – – – –.029" x .012" x 2" 943051 22 943052 31Luer.028" x .006" x 2" 943060 22 – – – –.028" x .012" x 2" 943061 22 943062 31

C Standard Pressure-Lok®.029" x .005" x 2" 943050 22 – – – –.029" x .012" x 2" 943051 22 – – – –Chaney adapter.018" x .008" x .75" – – – – 101935 55

D Standard Pressure-Lok®.029" x .012" x 2" 943051 22 943052 31Luer.028" x .012" x 2" 943061 22 943062 31

Magnum Standard Pressure-Lok®.035" x .023" x 2" 953050 22 953052 31Luer.035" x .023" x 2" 953061 22 953062 31

NEEDLE TIPS

Bevel, open end

Side port, taper

Page 14: Valco Cheminert - VICI - Resolution Systems

12

Gas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Replacement Components – Series A, A-2, C, and D

Plunger tips

Series: A A-2 C DSample size Prod No Price Prod No Price Prod No Price Prod No Price

100 µl 100017 $9 100017 $9 100017 $9 ––– –250 µl 100029 9 100029 9 100029 9 ––– –500 µl 013932 11 013932 11 013932 11 ––– –

1 ml 013933 13 013933 13 013933 13 013933 $ 1 32 ml 013934 13 013934 13 013934 13 013934 135 ml 013935 15 013935 15 013935 15 – – – –

10 ml 013936 15 013936 15 013933 15 – – – –

Front packing

Series: ASample size Prod No Price

100 µl 100010 $15250 µl 100028 15500 µl 100042 15

1 ml 100057 142 ml 100070 145 ml 100086 14

10 ml 100100 20

Plunger assemblies

Series: A A-2 C DSample size Prod No Price Prod No Price Prod No Price Prod No Price

25 µl ––– – 054123 $23 ––– – ––– –50 µl ––– – 054124 23 ––– – ––– –

100 µl 014425 $ 2 3 014425 23 014425 $ 2 3 – – – –250 µl 014431 23 014431 23 014431 23 – – – –500 µl 014432 29 014432 29 014432 29 – – – –

1 ml 014433 29 014433 29 014433 29 044433 $ 2 92 ml 014434 29 014434 29 014434 29 044434 295 ml 014435 29 014435 29 014435 29 – – – –

10 ml 014436 29 014436 29 014436 29 – – – –

Further reference

Series A ................... page 6Series A-2 ........................... 7Series C ............................... 8Series D ............................... 9

Replacement Components

Page 15: Valco Cheminert - VICI - Resolution Systems

13

Gas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid SyringesGas/Liquid Syringes

www.vici.com

Replacement Components – Magnum Series

Barrel assembly

Sample size Prod No Price

20 ml 065637 $13250 ml 065639 1 4 3

100 ml 065640 1 7 5250 ml 065641 3 1 9500 ml 065642 3 6 0

Front packing

Sample size Prod No Price

20 ml 065937 $ 9 950 ml 065939 1 0 1

100 ml 065940 1 0 3250 ml 065941 1 0 5500 ml 065942 1 0 8

Standard nosepiece

Sample size Prod No Price

20 ml 065037 $ 3 150 ml 065037 31

100 ml 065037 31250 ml 065041 31500 ml 065041 31

Luer nosepiece

Sample size Prod No Price

20 ml 065042 $ 3 350 ml 065042 33

100 ml 065042 33250 ml 065043 33500 ml 065043 33

Plunger rod

Includes thumbpiece.

Sample size Prod No Price

20 ml 065437 $ 3 350 ml 065439 39

100 ml 065440 44250 ml 065441 50500 ml 065442 50

Plunger tip

Sample size Prod No Price

20 ml 065537 $ 4 450 ml 065539 46

100 ml 065540 55250 ml 065541 72500 ml 065542 75

Sleeve, front

Sample size Prod No Price

20 ml 100288 $ 5 550 ml 100312 57

100 ml 100333 66250 ml 100352 88500 ml 100372 95

Sleeve, rear

Sample size Prod No Price

20 ml 100289 $ 4 450 ml 100313 46

100 ml 100334 55250 ml 100353 72500 ml 100373 75

Stem cap

Sample size Prod No Price

20 ml 100298 $ 1 550 ml 100298 15

100 ml 100343 11250 ml 100343 11500 ml 100343 11

Stem cap set screw

Sample size Prod No Price

20 ml 500635 $1.2550 ml 500635 1.25

100 ml 500635 1.25250 ml 500635 1.25500 ml 500635 1.25

Valve stem

Sample size Prod No Price

20 ml 100296 $ 2 250 ml 100320 22

100 ml 100341 22250 ml 100360 22500 ml 100379 22

Valve stem guide

Sample size Prod No Price

20 ml 100297 $ 2 450 ml 100321 24

100 ml 100342 24250 ml 100361 24500 ml 100361 24

Replacement Components

Further reference

Magnum series . page 10

Page 16: Valco Cheminert - VICI - Resolution Systems

14

Liquid SyringesLiquid SyringesLiquid SyringesLiquid SyringesLiquid Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Series C-160 Pressure-Lok®

Series C-160PTFE needle seat at rear of needle

Prevents possible dissolution of needle cementor contamination of the sample

Replaceable needlesComplete with integral PTFE seal for a low deadvolume connection and a leak-tight fit

Plunger tip of stress-formed virgin PTFESelf-lubricating and durable

Leak-tight to 250 psiLiquids and gases

The C-160 offers day-in, day-out dependability at aneconomical price. You also have the choice of fixed orremovable needles.

Series C-160 syringes

Fixed needle Removable needleSamplesize Prod No Price Prod No Price

5 µl 160021 $ 2 9 160221 $ 4 410 µl 160022 22 160222 30

25 µl 160023 26 160223 3450 µl 160024 29 160224 36

100 µl 160025 31 160225 39

Replacement needles

Bevel,open end

Package of 3: Prod No Price

.019" x .005" x 2.25" 123050 $27

SPECSFixed and removable

needlesBevel, open endFixed needle size:

.019" x .005" x 2"Removable needle size:

.019" x .005" x 2.25"250 psi max,

gases and liquids

Series C-160, 10 µl#160022

Series C-160, 25 µl#160223

Further reference

Replacementcomponents .. page 23

Page 17: Valco Cheminert - VICI - Resolution Systems

15

Liquid SyringesLiquid SyringesLiquid SyringesLiquid SyringesLiquid Syringes

www.vici.com

Series C-120 Pressure-Lok®

SPECSFixed needlesBevel, open endNeedle size:

.019" x .005" x 2"250 psi max,

gases and liquids

Series C-120Fixed needle

Zero dead volume connection

Leak-tight to 250 psiLiquids and gases

Extended syringe barrelAttach a bulb or suction line for easier cleaning and filling

In addition to standard Pressure-Lok® features such as PTFE plunger tip andneedle seat, the C-120 offers as standard equipment a barrel extensionbeyond the rear flange which permits attachment of a vacuum bulb or linefor easier filling or cleaning.

Series C-120 syringes

Fixed needleSamplesize Prod No Price

5 µl 120021 $ 4 310 µl 120022 43

25 µl 120023 4350 µl 120024 43

100 µl 120025 43

BARRELEXTENSION

Series C-120, 100 µl#120025

Further reference

Replacementcomponents .. page 23

Page 18: Valco Cheminert - VICI - Resolution Systems

16

Liquid SyringesLiquid SyringesLiquid SyringesLiquid SyringesLiquid Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Series CG-130 Pressure-Lok®

Series CG-130, 5 µl#130021

Series CG-130, 10 µl#130222

Series CG-130Reinforced plunger

Eliminates plunger bending

Plunger guide in barrelSmaller front section of plunger is confined withinguide section

Replaceable needlesLow dead volume connection for a leak-tight fit

Leak-tight to 250 psiLiquids and gases

A heavy, reinforced plunger within an enlarged plungerguide section of the CG-130 barrel virtually eliminatesplunger bending. The smaller front section of theplunger is confined within the guide section even whenthe plunger is retracted, while the sturdy upper sectionabsorbs the force of a rapid downstroke.

Series CG-130 syringes

Fixed needle Removable needleSamplesize Prod No Price Prod No Price

5 µl 130021 $ 4 2 130221 $ 5 410 µl 130022 42 130222 54

Replacement needles

Bevel,open end

Package of 3: Prod No Price

.019" x .005" x 2.25" 123050 $27

SPECSFixed and removable

needlesBevel, open endFixed needle size:

.019" x .005" x 2"Removable needle size:

.019" x .005" x 2.25"250 psi max,

gases and liquids

Further reference

Replacementcomponents .. page 23

Page 19: Valco Cheminert - VICI - Resolution Systems

17

Liquid SyringesLiquid SyringesLiquid SyringesLiquid SyringesLiquid Syringes

www.vici.com

Series CGV-130 Pressure-Lok®

SPECSFixed needlesBevel, open endNeedle sizes:

.029" x .005" x 3.25"

.029" x .008" x 3.25"250 psi max,

gases and liquids

Series CGV-130Side vent

For easy cleaning and filling

Reinforced plungerEliminates plunger bending

Plunger guide in barrelSmaller front section of plunger is confined withinguide section

Leak-tight to 250 psiLiquids and gases

The CGV-130 features the same rugged construction as the CG-130, with theaddition of a side vent that can be used for filling or cleaning the syringe. Aheavy, reinforced plunger within an enlarged plunger guide section of thebarrel virtually eliminates plunger bending. The smaller front section of theplunger is confined within the guide section even when the plunger isretracted, while the sturdy upper section absorbs the force of a rapiddownstroke.

Series CGV-130 syringes

.005" ID needle .008" ID needleSamplesize Prod No Price Prod No Price

10 µl 139022 $ 7 7 – – – –25 µl 139023 77 – – – –50 µl 139024 77 139124 $ 8 3

100 µl 139025 77 139125 83

Series CGV-130.005" ID needle

25 µl#139023

Page 20: Valco Cheminert - VICI - Resolution Systems

18

Liquid SyringesLiquid SyringesLiquid SyringesLiquid SyringesLiquid Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Series D-140 Pressure-Lok®

Series D-140Total sample displacement

The entire sample is contained in the needle, so it istotally injected when the plunger is depressed

Positive rear plunger stopEliminates accidental plunger removal and resultantdamage

Modular constructionAll parts are replaceable, with easy assembly anddisassembly

The Series D-140 is designed for small volume injection into gas chromatographs.Since the sample is totally contained within the needle, it is totally displaced bythe plunger. Any residual sample or variation in sample size is minimized. (Thisalso means that each size syringe has a different needle design. When orderingextra needles, be careful to specify the correct one.)

The PTFE seals, needle, plunger, and barrel are all replaceable. (Replacement partsare on page 23.) Thanks to superior alignment, the D-140 can be assembled timeafter time without difficulty or damage.

Series D-140 syringes

Removable needleSamplesize Prod No Price

1 µl 140011 $ 6 82 µl 140012 685 µl 140021 70

10 µl 140022 70

Replacement needles

Package of 3.Blunt, Bevel, Side port,

Sample open end open end tapersize Prod No Price Prod No Price Prod No Price

1 µl .019" x .005" x 2.5" 923011 $ 3 3 – – – – – – – –2 µl .019" x .008" x 2.5" 923012 33 – – – – – – – –5 µl .028" x .012" x 2.5" – – – – 923021 $ 3 3 – – – –

10 µl .028" x .018" x 2.5" – – – – – – – – 923022 $ 5 3

SPECSRemovable needlesSize and style vary

with syringe size30 psi max, liquids only

Further reference

Replacementcomponents .. page 23

Series D-1400 - 2 µl

#140012

NEEDLE TIPS

1 and 2 µl:Blunt tip, open end

5 µl:Bevel point, open end

10 µl:Side port, taper

Page 21: Valco Cheminert - VICI - Resolution Systems

19

Liquid SyringesLiquid SyringesLiquid SyringesLiquid SyringesLiquid Syringes

www.vici.com

Mini Injector Pressure-Lok®

SPECSFixed needleBevel, open endNeedle size:

.028" x .019"

Mini InjectorReproducible sample injections down to 0.01 µl

Without a splitter

Sample carried in the plunger itselfThe groove containing the sample is machined on the plunger, insuringrepeatable results

The Mini Injector is ideal for capillary GC work, allowing reproducibleinjection of small samples (down to 0.01 µl) without a splitter. This ispossible through our unique use of a plunger-within-a-needle. The samplevolume is carried in a precisely measurable groove ringing the wire plunger,with a durable PTFE packing to prevent leakage.

In use, the plunger is extended beyond the needle tip and dipped into thesample, where capillary action fills the groove. Then the plunger is drawnthrough a PTFE wiper and back into the needle for protection. When theneedle is inserted into the inlet and the plunger is depressed, the samplecarried on the plunger groove enters the heated zone, where it is flash-vaporized and swept into the column.

Mini injector

Samplesize Prod No Price

.01 µl 170091 $108

.10 µl 170001 108

Replacement wiper

Samplesize Prod No Price

.01 µl 100667 $ 1 1

.10 µl 100667 11

Mini injector0.01 µl

#170091

Page 22: Valco Cheminert - VICI - Resolution Systems

20

Liquid SyringesLiquid SyringesLiquid SyringesLiquid SyringesLiquid Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Pressure-Lok® Syringes for Valco, Cheminert®, and Rheodyne® Valves

Syringes for Valco, Cheminert®, and Rheodyne® ValvesSyringes used to fill a loop on a sample injectionvalve have blunt smooth ends. The end of theneedle must contact the bottom of the valve’sfitting detail uniformly and seal on the outside ofthe tip to deliver sample with any repeatability.All VICI Precision Sampling syringes for valveinjections have smooth, burr-free ends that fit thevalve fitting details perfectly. The standard HPLCsyringe is our basic C-160 with a 2" long 22 gaugeneedle.

Syringes

Fixed needle Removable needleSamplesize Prod No Price Prod No Price

5 µl 160021R $ 2 9 160221R $ 4 410 µl 160022R 22 160222R 30

25 µl 160023R 26 160223R 3450 µl 160024R 29 160224R 36

100 µl 160025R 31 160225R 39

Replacement needles

Blunt tip,open end

Package of 3: Prod No Price

22 gauge x 2" 123050R $ 2 7

SPECSFixed and removable

needlesBlunt tip, open endFixed needle size:

22 gauge x 2"Removable needle size:

22 gauge x 2"250 psi max,

gases and liquids

Further reference

C-160 syringe .... page 14

Page 23: Valco Cheminert - VICI - Resolution Systems

21

Liquid SyringesLiquid SyringesLiquid SyringesLiquid SyringesLiquid Syringes

www.vici.com

Special Syringes for Rheodyne® ValvesMany Rheodyne valves allow the syringe needle to rub across the sealing surfaces –a tradeoff in a valve design which avoids having to machine small concentricholes. To prolong the lifetime of these valves, VICI Precision Sampling offers asyringe with a PEEK tip which extends beyond the end of the needle so that onlyPEEK contacts the valve sealing surfaces.

Syringes

Fixed needle Removable needleSamplesize Prod No Price Prod No Price

5 µl 160021RT $ 3 4 160221RT $ 5 010 µl 160022RT 28 160222RT 36

25 µl 160023RT 32 160223RT 4050 µl 160024RT 34 160224RT 42

100 µl 160025RT 36 160225RT 44

Replacement needles

Blunt PEEK tip,open end

Package of 3: Prod No Price

22 gauge x 2" 123050RT $32

Syringes for Cheminert Nanovolume Injector andWaters U6K Loop InjectorThese injectors require a 26 gauge, 5 cm long needle with a 90° blunt tip andopen end. We recommend mounting the needle on our basic C-160 syringe.(The C-160 is described on page 14.)

Syringes

Fixed needle Removable needleSamplesize Prod No Price Prod No Price

5 µl 160021WB $ 2 9 160221WB $ 4 410 µl 160022WB 22 160222WB 30

25 µl 160023WB 26 160223WB 3450 µl 160024WB 29 160224WB 36

100 µl 160025WB 31 160225WB 39

Replacement needles

Bevel,open end

Package of 3: Prod No Price

26 gauge x 5 cm 123050WB $ 2 6

SPECSFixed and removable

needlesBlunt PEEK tip, open endFixed needle size:

22 gauge x 2"Removable needle size:

22 gauge x 2"250 psi max,

gases and liquids

SPECSFixed and removable

needlesBlunt tip, open endFixed needle size:

26 gauge x 5 cmRemovable needle size:

26 gauge x 5 cm250 psi max,

gases and liquids

Further reference

C-160 syringe .... page 14

Pressure-Lok® Syringes for Rheodyne®, Cheminert®, and Waters U6K Loop Injectors

Page 24: Valco Cheminert - VICI - Resolution Systems

22

Liquid SyringesLiquid SyringesLiquid SyringesLiquid SyringesLiquid Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Purge and Trap Pressure-Lok® Syringes

Purge and Trap SyringeLuer lock

For use with purge and trap analysis

Frosted glass on syringe barrelAllows easy volume reading and accepts writing

Plunger tip of stress-formed virgin PTFESelf-lubricating and durable

Heavy duty rear flangeFlat edges keep the syringe from rolling

The heavy duty construction of our purge and trap syringehelps eliminate costs of replacement and injuries due tobreakage. All of our environmental syringes are repairable.

Syringes

Samplesize Prod No Price

5 ml 030039 $ 5 910 ml 030040 65

Syringes with push-button valve

Samplesize Prod No Price

5 ml 050039 $ 8 310 ml 050040 83

SPECSAccepts standard Luerhub needles

Purge and trap syringe5 ml

#030039

Page 25: Valco Cheminert - VICI - Resolution Systems

23

Liquid SyringesLiquid SyringesLiquid SyringesLiquid SyringesLiquid Syringes

www.vici.com

Replacement Components

Replacement Components – Liquid Syringes

Replacement needles

Package of 3: Blunt, Bevel, Side port,open end open end taper

Series Prod No Price Prod No Price Prod No Price

C-160 .019" x .005" x 2.25" – – – – 123050 $ 2 7 – – – –CG-130 .019" x .005" x 2.25" – – – – 123050 27 – – – –D-140 .019" x .005" x 2.5" 923011 $ 3 3 – – – – – – – –

.019" x .008" x 2.5" 923012 33 – – – –

.028" x .012" x 2.5" – – – – 923021 33 – – – –

.028" x .018" x 2.5" – – – – – – – – 923022 $ 5 3

Further reference

Series C-120 ....... page 15Series C-160 ................... 14Series CG-130 ............... 16Series D-140 .................. 18

NEEDLE TIPS

Blunt tip, open end

Bevel point, open end

Side port, taper

Plunger assemblies

Series C-160 Series C-120 Series CG-130 Series D-140Sample size Prod No Price Prod No Price Prod No Price Prod No Price

1 µl – – – – – – – – – – – – 143711 $ 2 82 µl – – – – – – – – – – – – 143712 28

5 µl 163721 $ 1 5 123721 $ 2 5 133721 $ 2 8 143721 2810 µl 163722 15 123722 25 133722 28 143722 28

25 µl 163723 15 054123 25 – – – – – – – –50 µl 163724 15 054124 25 – – – – – – – –

100 µl 163725 15 054125 25 – – – – – – – –

Plunger Packings – D-140 series only

Sample Size Prod No Price

1 µl 144011 $92 µl 144012 95 µl 144021 9

10 µl 144022 9

Page 26: Valco Cheminert - VICI - Resolution Systems

24

Autosampler and OEM SyringesAutosampler and OEM SyringesAutosampler and OEM SyringesAutosampler and OEM SyringesAutosampler and OEM Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Varian Autosampler Syringes

Autosampler SyringesAll our autosampler syringes conform to specifications supplied by themanufacturer.

Varian

We supply the syringes for the Varian GC 511, PTA30, PTA30WS, and Archoninstruments.

For Prod No Price Description Needle Size Ga.

511 1.5 µl 102103 $ 9 4 Taper, blunt, .028" x .008" x 2" 225 µl 102100 61 and open .024" x .006" x 2" 23

50 µl 102102 61 end needle .024" x .006" x 2" 23

PTA 030038 $ 8 3 LuerPTA30WS 030038 83 fittingDynatrap 030038 83

Archon 502968 $125 26 ml barrelwith decal

Autosampler syringefor 511-5 µl

#102100

Page 27: Valco Cheminert - VICI - Resolution Systems

25

Autosampler and OEM SyringesAutosampler and OEM SyringesAutosampler and OEM SyringesAutosampler and OEM SyringesAutosampler and OEM Syringes

www.vici.com

Perkin Elmer and Central Instruments Autosampler Syringes

Perkin Elmer

Taper, blunt,& open end

For Size Ga. Prod No Price

5 µl GC Autosystem .024" x .006" x 70 mm 23 102052 $61.022" x .005" x 70 mm 24 101989 61

Autosampler syringe for5 µl GC Autosystem

#102052

Central Instruments Co.

Replacement syringes and needles for models GC-311, GC-111, GC-411, andPerkin Elmer models AS100 and AS300.

Syringes Standard Viscous MegaboreSample size Prod No Price Prod No Price Prod No Price

3 µl 500076 $ 6 0 501071 $ 7 3 503188 $ 6 05 µl 500084 60 501072 73 – – – –

10 µl 500090 60 501073 73 – – – –

Standard, 3 µl#500076

Needles Standard Viscous MegaboreSample size Prod No Price Prod No Price Prod No Price

3 µl 500081 $ 3 2 500994 $ 3 5 502743 $ 3 85 µl 500088 32 501040 35 – – – –

10 µl 501064 32 501092 35 – – – –

Standard, 3 µl#500081

Page 28: Valco Cheminert - VICI - Resolution Systems

26

High Pressure SyringesHigh Pressure SyringesHigh Pressure SyringesHigh Pressure SyringesHigh Pressure Syringes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Pressure-Flo® Syringes

Pressure-Flo® SyringesSeals at 500 psi

Take high pressure samples from a cylinder or "bomb"

Sample contained in a calibrated needleInjects directly through the GC septum inlet

Use with cylinder adapterLets syringe interface with gas cylinder

The Pressure-Flo high pressure syringe is a tried and true method of takinghomogeneous high pressure samples from a cylinder or “bomb”. It containsthe sample in a calibrated needle with a wire plunger to displace it and PTFEpacking to seal it in, permitting injection of the sample directly through theGC septum inlet for convenience and simplicity.

The body of the syringe is lightweight for easy handling. It houses a specialcrimped PTFE packing which seals firmly at pressures up to 500 psi even undersevere operating conditions. Threads allow the syringe to make up on a cylindervia the special adapters listed below. Once the syringe is screwed tight, thecylinder valve is opened and the plunger is depressed, extending the needle intothe liquid zone. Once sample is drawn into the syringe, it is stored pressure-tightwhile the cylinder valve is closed and the syringe is removed from the adapter.

To inject the sample, the nose of the syringe is pressed very firmly against theseptum to form a pressure-tight seal. (This requires a minimum 1/8" hole in theseptum cap.) As this is done, the pointed tip of the needle punctures the septum.When the large handle is pushed in, the needle containing the sample is insertedinto the injection port without any loss of contents.

SPECSSpecial integralcalibrated plunger

Needle size:22 gauge

500 psi max,liquids only

Pressure-Flo, 0.5 µl#220005

Bomb adapter1/4" male#240043

Bomb adapter1/4" female

#240041

Pressure-Flo syringes

Samplesize Prod No Price

.5 µl 220005 $1871 µl 220011 1 8 72 µl 220012 1 8 7

5 µl 220021 1 8 710 µl 220022 1 8 7

Bomb adapters

Prod No Price

Fitting (NPT)1/8" female 240040 $751/4" female 240041 75

1/8" male 240042 751/4" male 240043 75

Further reference

Replacementcomponents .. page 27

Page 29: Valco Cheminert - VICI - Resolution Systems

27

High Pressure SyringesHigh Pressure SyringesHigh Pressure SyringesHigh Pressure SyringesHigh Pressure Syringes

www.vici.com

Micro-Flo® Syringes

SPECSAnnular needleSide port, tapered,

open endNeedle size:

.028" x .006" x1.875"500 psi max,

gases and liquids

Micro-Flo® SyringesMetal-encased syringe with PTFE seals

For hard-to-handle volatile liquids and liquified gases

Special locking cylinder adapter and yoke assemblyThe syringe contacts the sample liquid in its pure, undisturbed state

Sample Lok valveSeals in volatile materials at pressures up to 500 psi

Variable volume0.5 to 5.0 µl

The Micro-Flo high pressure syringe prevents evaporation of lightercomponents under normal laboratory temperatures at atmospheric pressure.The syringe is encased in metal, with positive PTFE seals and positive plungerstops. The front end houses a special micro-volume annular needle with lessthan .05 µl dead volume and a positive mechanical valve to seal in volatilematerials (up to 500 psi).

Micro-Flo syringes

Prod No Price

Syringe 230051 $286Adapter 230250 286

Replacement Components for High Pressure SyringesPressure-Flo series

Sample size: 0.5 µl 1 µl 2 µl 5 µl 10 µlProd No Price Prod No Price Prod No Price Prod No Price Prod No Price

Plunger assembly 220315 $42 220311 $42 220312 $42 220321 $42 220322 $42

Sample size: 0.5 µl 1, 2, 5,and 10 µl

Prod No Price Prod No Price

Needles 220351 $31 220352 $31Plunger packing 100800 9 220347 9Front packing assy 220344 64 220344 64

Micro-Flo series

Prod No Price

Needle 100838 $55Plunger assembly 100854 77Front packing 100828 10Barrel with decal 100827 50Rear washer 100826 6Spring 100830 6

Cylinder adapter and yoke assembly

Prod No Price

Syringe side packing 100844 $20Plunger pin

rod assembly 100846 39Plunger pin

side packing 100848 20

Micro-Flo syringe#230051

Micro-Floadapter#230250

Page 30: Valco Cheminert - VICI - Resolution Systems

28

MininerMininerMininerMininerMininert™ t™ t™ t™ t™ VVVVValvalvalvalvalve se se se se s

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

General Description

Mininert™ ValvesLeak-tight closure with syringe access

Take a sample with no exposure of vial contents to the atmosphere

Models for virtually any laboratory glasswareScrew-cap and crimp-top vials, test tubes, flasks, reaction chambers,1/4-28 or pipe thread

EconomicalSave time and money through conservation of reagents, etc.

Replaceable septumEasily replaced with no exposure of contents to atmosphere

Simple installationNo tools required

Mininert push-button valves are highly dependable, leak-tight closures forscrew-cap vials and other laboratory containers. When used with a glass vial,only PTFE and glass are in contact with the contents. Their unique featuresmake Mininert valves the ideal closure for calibration standards, air- ormoisture-sensitive fluids, derivatizing reagents, volatile chemicals, etc.

Operation is extremely simple – push the green button to open the valve,insert the needle through the septum and take a sample, withdraw theneedle, and push the red button to close the valve.

SPECS

TEMPERATURE

Mininert valves can beused at temperature up to105°F. However, after useat high temperatures, thevalve may leak slightlywhen cooled to roomtemperature.

PRESSURE

The sealing ability ofMininert valves is morethan adequate to containmost volatile liquids andgases at low pressures.Mininert valves have beenused as high as 120 psiwithout leakage, but thisis NOT a recommendationfor pressurizing glasscontainers to these levels.Such pressurization ofglass containers can beextremely dangerous.

CHEMICALRESISTANCE

PTFE is highly inert andmay be used with mostcommon materials. It isparticularly useful forworking with most acidsand organic solvents.However, problems maybe encountered whenused with organometallicsand some strong bases.We recommend actualexposure test before usewith any material.

Valves for vials

The screw-cap Mininert is available in a variety of sizes.The crimp-top valve for 13 mm ID glassware slides intothe neck of the vial and features a threaded flange whichis turned to provide a leak-tight fit.

Pkg/12: Cap / thread size Prod No Price

13 mm-425 614158 $7315 mm-425 614160 75

18 mm-400 614161 7920 mm-400 614170 8424 mm-400 614163 88

Crimp top 614250 99

Page 31: Valco Cheminert - VICI - Resolution Systems

29

MininerMininerMininerMininerMininert™ t™ t™ t™ t™ VVVVValvalvalvalvalve se se se se s

www.vici.com

Valves and Septa

Valves with standard tapers

The laboratory taper model brings Mininert convenience and ease to avariety of applications using standard laboratory glassware, such as reactionchambers, test tubes, and other glass systems.

Taper Prod No Price

14/20 621102 $ 2 419/22 621103 24

Valves with threaded fittings

Our threaded designs offer positive on/off fluid control as an in-line valve orsyringe access as a termination valve at a sample point. In-line valves are1/4-28 male to male or 1/4-28 female to female. Termination valves areoffered in 1/4-28 male or female and 1/8" NPT male or female.In-line valves Prod No Price

1/4-28 male to male 631205 $291/4-28 female to female 631206 29

Termination valves

1/4-28 male 631201 241/4-28 female 631203 24

1/8" NPT male 631202 241/8" NPT female 631204 29

Replacement septa and septum installation tool

These silicone septa fit all Mininert valves. The installation tool is a handydevice for quickly removing and replacing needle seal septa.

Prod No Price

Septa, pkg/50 644350 $26Installation tool 644850 23

Mininert syringe valves

These convenient add-on valves allow our Series C and D syringes to storesamples at up to 250 psi. The valve body is all PTFE, with a stainless steelstem. Also available to fit luer-tip syringes from any manufacturer.

Prod No Price

For C or D syringe 654050 $ 1 8For Luer-tip syringe 654051 19

Page 32: Valco Cheminert - VICI - Resolution Systems

30

ProbesProbesProbesProbesProbes

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

GC and LC Probesfor Central Instruments AutosamplersProbes are used to transfer liquid sample from a sample vial to the injectionsyringe by pressurizing the sample vial with helium.

GC probes

Prod No Price

GC-111H 500031 $193GC-111V 500100 193GC-311V 500100 193GC-411V 500100 193GC-311H 500441 193

Perkin-ElmerAS-300 500523 193

LC probes

Prod No Price

LC-241 42 position 500335 $193LC-241 60 position 500301 193

LC and GC Probes

Page 33: Valco Cheminert - VICI - Resolution Systems

31

ProbesProbesProbesProbesProbes

www.vici.com

Varian Probes

PTA-30, WS, and DynaTrap Instruments

Prod No Price Prod No Price

Syringe probe assembly 502971 $84 ––– –

With fittings Without fittingsProd No Price Prod No Price

Needle purge upper probe 505193 $328 505118 $275Upper soil probe assembly 505032 299 503840 253

Varian Archon Instruments

With fittings Without fittingsProd No Price Prod No Price

Water probe assembly 505739 $264 505828 $230Water probe (old style) 505491 277 505831 240

Soil probe assembly 505490 3 0 8 505830 2 5 0Needle purge probe assembly 505741 2 6 4 505829 2 3 0

Syringe probe assembly#502971

Needle purge probe assemblywithout fittings

#505829

Page 34: Valco Cheminert - VICI - Resolution Systems

5 cm = 1.97"10 cm = 3.94"20 cm = 7.87"30 cm = 11.82"50 cm = 19.68"

100 cm = 39.37"

32

TTTTTubingubingubingubingubing

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Pre-cut Stainless

Stainless Steel Tubing inPre-cut LengthsThese packages of pre-cutType 316 stainless tubing providean economical solution to the problemsthat are caused by “seat-of-the-pants”cutting in the lab or field. They arepriced to give a savings over the $2 percut charge for custom-cut tubing.

All tubing is electrolytically cut andspecially steam-cleaned with micro-filtered steam from deionized water,which removes both organic andinorganic contaminants.

TECH TIP

Thirty five years of VICIexperience show that theparticles left in poorly cuttubing are the numberone cause of valvedamage.

1/32" OD stainless tubing Pre-cut lengths

0.005" ID 0.010" ID 0.020" IDLength Prod No Price Prod No Price Prod No Price

2 pieces per package5 cm T5N5D $7 T5N10D $7 T5N20D $7

10 cm T10N5D 7 T10N10D 7 T10N20D 720 cm T20N5D 9 T20N10D 9 T20N20D 9

30 cm T30N5D 11 T30N10D 11 T30N20D 1150 cm T50N5D 13 T50N10D 13 T50N20D 13

100 cm T100N5D 20 T100N10D 20 T100N20D 20

10 pieces per package5 cm T5N5-10 34 T5N10-10 34 T5N20-10 34

10 cm T10N5-10 34 T10N10-10 34 T10N20-10 3420 cm T20N5-10 44 T20N10-10 44 T20N20-10 44

30 cm T30N5-10 50 T30N10-10 50 T30N20-10 5050 cm T50N5-10 60 T50N10-10 60 T50N20-10 60

100 cm T100N5-10 92 T100N10-10 92 T100N20-10 92

50 pieces per package5 cm T5N5-50 153 T5N10-50 153 T5N20-50 153

10 cm T10N5-50 153 T10N10-50 153 T10N20-50 15320 cm T20N5-50 216 T20N10-50 216 T20N20-50 216

30 cm T30N5-50 235 T30N10-50 235 T30N20-50 23550 cm T50N5-50 275 T50N10-50 275 T50N20-50 275

100 cm T100N5-50 449 T100N10-50 449 T100N20-50 449

100 pieces per package5 cm T5N5-100 286 T5N10-100 286 T5N20-100 286

10 cm T10N5-100 286 T10N10-100 286 T10N20-100 28620 cm T20N5-100 398 T20N10-100 398 T20N20-100 398

30 cm T30N5-100 433 T30N10-100 433 T30N20-100 43350 cm T50N5-100 516 T50N10-100 516 T50N20-100 516

100 cm T100N5-100 854 T100N10-100 854 T100N20-100 854

Page 35: Valco Cheminert - VICI - Resolution Systems

0.12 mm = .005"0.25 mm = .010"0.50 mm = .020"0.75 mm = .030"

1.0 mm = .040"1.5 mm = .060"2.0 mm = .080"

4.6 mm = .180"6.0 mm = .236"6.4 mm = .253"

7.0 mm = .275"10.0 mm = .400"

1/32" = 0.8 mm1/16" = 1.6 mm1/8" = 3.2 mm

1/4" = 6.4 mm3/8" = 9.5 mm1/2" = 12.7 mm

5 cm = 1.97"10 cm = 3.94"20 cm = 7.87"30 cm = 11.82"50 cm = 19.68"

100 cm = 39.37"

33

TTTTTubingubingubingubingubing

www.vici.com

Pre-cut Stainless

1/16" OD stainless tubing Pre-cut lengths

0.005" ID 0.010" ID 0.020" ID 0.030" ID 0.040" IDLength Prod No Price Prod No Price Prod No Price Prod No Price Prod No Price

2 pieces per package

5 cm T5C5D $7 T5C10D $7 T5C20D $7 T5C30D $7 T5C40D $710 cm T10C5D 7 T10C10D 7 T10C20D 7 T10C30D 7 T10C40D 720 cm T20C5D 9 T20C10D 9 T20C20D 9 T20C30D 9 T20C40D 9

30 cm T30C5D 11 T30C10D 11 T30C20D 11 T30C30D 11 T30C40D 1150 cm T50C5D 13 T50C10D 13 T50C20D 13 T50C30D 13 T50C40D 13

100 cm T100C5D 20 T100C10D 20 T100C20D 20 T100C30D 20 T100C40D 20

10 pieces per package5 cm T5C5-10 34 T5C10-10 34 T5C20-10 34 T5C30-10 34 T5C40-10 34

10 cm T10C5-10 34 T10C10-10 34 T10C20-10 34 T10C30-10 34 T10C40-10 3420 cm T20C5-10 44 T20C10-10 44 T20C20-10 44 T20C30-10 44 T20C40-10 44

30 cm T30C5-10 50 T30C10-10 50 T30C20-10 50 T30C30-10 50 T30C40-10 5050 cm T50C5-10 60 T50C10-10 60 T50C20-10 60 T50C30-10 60 T50C40-10 60

100 cm T100C5-10 92 T100C10-10 92 T100C20-10 92 T100C30-10 92 T100C40-10 92

50 pieces per package5 cm T5C5-50 153 T5C10-50 153 T5C20-50 153 T5C30-50 153 T5C40-50 153

10 cm T10C5-50 153 T10C10-50 153 T10C20-50 153 T10C30-50 153 T10C40-50 15320 cm T20C5-50 216 T20C10-50 216 T20C20-50 216 T20C30-50 216 T20C40-50 216

30 cm T30C5-50 235 T30C10-50 235 T30C20-50 235 T30C30-50 235 T30C40-50 23550 cm T50C5-50 275 T50C10-50 275 T50C20-50 275 T50C30-50 275 T50C40-50 275

100 cm T100C5-50 449 T100C10-50 449 T100C20-50 449 T100C30-50 449 T100C40-50 449

100 pieces per package5 cm T5C5-100 286 T5C10-100 286 T5C20-100 286 T5C30-100 286 T5C40-100 286

10 cm T10C5-100 286 T10C10-100 286 T10C20-100 286 T10C30-100 286 T10C40-100 28620 cm T20C5-100 398 T20C10-100 398 T20C20-100 398 T20C30-100 398 T20C40-100 398

30 cm T30C5-100 433 T30C10-100 433 T30C20-100 433 T30C30-100 433 T30C40-100 43350 cm T50C5-100 516 T50C10-100 516 T50C20-100 516 T50C30-100 516 T50C40-100 516

100 cm T100C5-100 854 T100C10-100 854 T100C20-100 854 T100C30-100 854 T100C40-100 854

VOLUME CHART

Tubing Volume Tubing VolumeID ID

µl/cm µl/in µl/cm µl/in

.005" 0.13 0.32 .030" 4.56 11.58

.010" 0.51 1.29 .040" 8.11 20.59

.015" 1.14 2.90 .060" 18.24 46.33

.020" 2.03 5.15 .070" 24.83 63.06

.025" 3.17 8.04 .085" 36.61 92.99

Typical ID tolerances for our tubing are ±.001". This is much tighterthan normal commercial grades of tubing; however, it is enough toresult in noticeable error if exact volumes are not measured.

Page 36: Valco Cheminert - VICI - Resolution Systems

34

TTTTTubingubingubingubingubing

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Custom Lengths - Metal and Polymeric

Tubing in Custom LengthsMetal tubing is electrolytically cut anddeburred, then steam cleaned. Polymerictubing is square-cut and ready to use.Specify the length required, in inches orfeet. For pricing of custom tubing, thelength is rounded up to the next foot. Forexample, a 5" piece is charged as one foot; an18" piece as two feet. For metal tubing, add $2cutting/cleaning charge for each length.

Metal tubing Custom lengths

316 Stainless Nickel 200 Titanium * Hastelloy CSize Prod No Price/ft Prod No Price/ft Prod No Price/ft Prod No Price/ft

1/32" OD tubing.005" ID TSS.505 $3.25 .007" ID TSS.507 3.25 TNI.507 $5.50 –

.010" ID TSS.510 3 .25 TNI.510 5.00

.020" ID TSS.520 3 .25 TNI.520 5.00

1/16" OD tubing.005" ID TSS105 3.25 TNI105 5.50 .010" ID TSS110 3.25 TNI110 5.50 TI112 $50.00 –

.015" ID TSS115 3.25

.020" ID TSS120 3.25 TNI120 5.00 TTI120 50.00

.026" ID TSS126 3.25 –

.030" ID TSS130 3 .25 TNI130 5 .00 TTI131 50 .00 THC130 $14 .00

.040" ID TSS140 3 .25 TNI140 5 .00

1/8" OD tubing.030" ID TSS230 4 .50 –.040" ID TSS240 4 .50 –

.060" ID TSS260 4 .50

.070" ID TSS267 4 .50 THC270 20 .00

.085" ID TSS285 4 .00 TNI285 7 .00

* Titanium tubing is typically available with a maximum length of 6 feet.

Polymeric tubing Custom lengths

PTFE FEP PEEK ETFESize Prod No Price/ft Prod No Price/ft Prod No Price/ft Prod No Price/ft

1/16" OD tubing.006" ID TTF106 $ 1.25 – –– TPK106 $3.50 – –.010" ID TTF110 1.25 TFEP110 $1.50 TPK110 2.50 TTZ110 $2.25.015" ID TTF115 1.25 – –– TPK115 2.50 – –

.020" ID TTF120 1.25 TFEP120 1.50 TPK120 2.50 TTZ120 2.25

.030" ID TTF130 1.25 TFEP130 1.50 TPK130 2.50 TTZ130 2.25

.040" ID TTF140 1.25 – –– – – – – –

1 /8" OD tubing.030" ID TTF230 1.60 – –– – – – – –.060" ID TTF260 1.60 TFEP260 1.75 TPK260 4.00 TTZ260 3.25.085" ID TTF285 1.60 – –– – – – – –

Further reference

Volume chart ................ 33Color-coded

PEEK tubing ................ 35

Page 37: Valco Cheminert - VICI - Resolution Systems

0.12 mm = .005"0.25 mm = .010"0.50 mm = .020"0.75 mm = .030"

1.0 mm = .040"1.5 mm = .060"2.0 mm = .080"

4.6 mm = .180"6.0 mm = .236"6.4 mm = .253"

7.0 mm = .275"10.0 mm = .400"

1/32" = 0.8 mm1/16" = 1.6 mm1/8" = 3.2 mm

1/4" = 6.4 mm3/8" = 9.5 mm1/2" = 12.7 mm

5 cm = 1.97"10 cm = 3.94"20 cm = 7.87"30 cm = 11.82"50 cm = 19.68"

100 cm = 39.37"

35

TTTTTubingubingubingubingubing

www.vici.com

Color-Coded PEEK

1/16" Color-Coded PEEK TubingPremium grade tubing with tighter tolerances

Easy to cut

Biocompatible

PEEK tubing is strong enough for continuous use at HPLC pressurewithout swelling or bursting. The dense polymer structure of VICIPEEK tubing eliminates the permeability to organic solvents thatcauses other polymer tubing, such as ETFE, to “sweat”.

PEEK tubing is compatible with almost any of the solvents commonly used inHPLC. It is not affected by halide salts, high strength buffers, or other aggressivemobile phases that corrode stainless steel. The polymer surface will not leachmetal ions into the eluent or extract metal-sensitive components from the sample.However, dichloromethane, THF, and DMSO may cause the tubing to swell.

Our striped PEEK tubing is manufactured of virgin natural PEEK, coded with acolored stripe for easy identification of the tubing ID. The color dye for the stripeis applied only to the outer surface, ensuring maximum chemical resistance andbiocompatibility.

SPECSMaterialPEEK

Pressure ratingSee chart below

Max. recommendedworking temp:< 100°C (continuous) for1/16" tubing with ID upto .030"

Further reference

Volume chart ................ 33Clean-Cut

tubing cutter ............. 36Tubing elbows .............. 36Fingertight fittings 42-46Flangeless fittings ...... 41

1/16" OD premium grade PEEK tubing Striped color-coded

Tolerance ID and OD: ±0.025 mm (.001")

Length: 5 feet 10 feet 25 feet bar* psi* ID Color Prod No Price Prod No Price Prod No Price

.005" Red JR-T-5999-F5 $15.00 JR-T-5999-F10 $30.00 JR-T-5999-F25 $72.00 4 2 0 6100

.007" Yellow JR-T-6000-F5 12.50 JR-T-6000-F10 25.00 JR-T-6000-F25 60.00 4 0 0 5800

.010" Blue JR-T-6001-F5 12.50 JR-T-6001-F10 25.00 JR-T-6001-F25 60.00 3 8 6 5600

.020" Orange JR-T-6002-F5 12.50 JR-T-6002-F10 25.00 JR-T-6002-F25 60.00 3 5 0 4500

.030" Green JR-T-6003-F5 12.50 JR-T-6003-F10 25.00 JR-T-6003-F25 60.00 2 4 0 3500

.040" Gray JR-T-60031-F5 12.50 JR-T-60031-F10 25.00 JR-T-60031-F25 60.00 1 6 5 2400

.055" Black JR-T-60032-F5 12.50 JR-T-60032-F10 25.00 JR-T-60032-F25 60.00 52 7 5 0

1/16" OD premium grade PEEK tubing Solid color-coded

Tolerance ID and OD: ±0.025 mm (.001")

Length: 5 feet 10 feet 25 feet bar* psi* ID Color Prod No Price Prod No Price Prod No Price

.005" Red JR-T-6007-F5 $15.00 JR-T-6007-F10 $30.00 JR-T-6007-F25 $72.00 4 2 0 6100

.007" Yellow JR-T-6008-F5 12.50 JR-T-6008-F10 25.00 JR-T-6008-F25 60.00 4 0 0 5800

.010" Blue JR-T-6009-F5 12.50 JR-T-6009-F10 25.00 JR-T-6009-F25 60.00 3 8 6 5600

.020" Orange JR-T-6010-F5 12.50 JR-T-6010-F10 25.00 JR-T-6010-F25 60.00 3 5 0 4500

.030" Green JR-T-6011-F5 12.50 JR-T-6011-F10 25.00 JR-T-6011-F25 60.00 2 4 0 3500

* Recommended maximum permanent working pressure(measured with ACN/Water 1:1 at room temperature)

Page 38: Valco Cheminert - VICI - Resolution Systems

36

TTTTTubingubingubingubingubing

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Clean-Cut polymer tubing cutter

For leak-free tubing connections in an LC system, right angles and clean cuts areessential. The Clean-Cut makes burr-free perpendicular cuts on polymeric tubingwithout distorting the outside diameter or closing the inside diameter. The handypocket-sized tool features a unique safety locking mechanism to secure the bladewhen not in use.

Prod No Price

Clean-Cut tubing cutter JR-797 $ 1 5Replacement blade JR-798 2

Tubing Accessories

Guillotine polymer tubing cutter

Prod No Price

Guillotine tubing cutter JR-794 $7.00Replacement blade JR-795 2.60

PEEK tubing elbows

Tubing elbows (90° and 180°) are ideal for routing 1/16"PEEK tubing through an LC system. These elbows areproportioned to bend PEEK tubing at the optimum radiusfor maximum chemical resistance and burst pressure.Installation is simple – just snap the tubing into the elbow.

Prod No Price

90° elbow JR-357090 $1.40180° elbow JR-357180 1.40

Tubing clip – the LC tubing organizer

The tubing clip holds 1/16" and 1/8" polymer tubingprecisely where you want them in your beakers, flasks,bottles, etc. up to 4 mm wall thickness. The stainlesssteel spring ensures a long lifetime.

Prod No Price

Tubing clip JR-9001 $2

Page 39: Valco Cheminert - VICI - Resolution Systems

0.12 mm = .005"0.25 mm = .010"0.50 mm = .020"0.75 mm = .030"

1.0 mm = .040"1.5 mm = .060"2.0 mm = .080"

4.6 mm = .180"6.0 mm = .236"6.4 mm = .253"

7.0 mm = .275"10.0 mm = .400"

1/32" = 0.8 mm1/16" = 1.6 mm1/8" = 3.2 mm

1/4" = 6.4 mm3/8" = 9.5 mm1/2" = 12.7 mm

5 cm = 1.97"10 cm = 3.94"20 cm = 7.87"30 cm = 11.82"50 cm = 19.68"

100 cm = 39.37"

37

TTTTTubingubingubingubingubing

www.vici.com

Tubing Accessories

Easy-Flange kit

The Easy-Flange flange-rolling tool uses mechanical force to form a flange on1/16" or 1/8" OD PTFE tubing, offering an excellent non-electric alternative to theheated flanging tool.

The quality of the flange is excellent, since it is formed without stressing thetubing by heat. The specially-designed negative conical profile of the flange-forming component yields an ideal shape for maximum sealing properties.

Prod No Price

Easy-Flange kit JR-201540 $140Includes:Plastic boxFlanging discs with:

0.5 mm SS pin for PEEK tubing0.8 mm polymer pin0.8 mm titanium pin1.3 mm polymer pin1.3 mm titanium pin

Clean-cut tubing cutterPTFE tubing, 1/16" x 0.75 mm ID, 6 ft.

Optional and spare partsFlanging disc with:

0.5 mm SS pin for PEEK tubing JR-202235 $20.000.8 mm polymer pin JR-201541 12.000.8 mm titanium pin JR-201554 16.701.0 mm polymer pin JR-201662 12.501.3 mm polymer pin JR-201536 12.001.3 mm titanium pin JR-201537 16.701.5 mm polymer pin JR-201663 12.50

Flanging clamp JR-201531 60.00Clean-Cut tubing cutter JR-797 15.00

Easy-Flange Combi kit

The Easy-Flange Combi kit is an upgraded version of the standard kit, and comescomplete with PTFE tubing, PPS nuts, and polypropylene O-rings.

Prod No Price

Easy-Flange kit JR-201539 $163Includes:Plastic boxFlanging discs with:

0.5 mm SS pin for PEEK tubing0.8 mm polymer pin0.8 mm titanium pin1.3 mm polymer pin1.3 mm titanium pin

Clean-cut tubing cutterPPS nuts for 1/16" tubing, with O-rings, pkg. of 10PPS nuts for 1/8" tubing, with O-rings, pkg. of 10PP fingertight adapters, pkg. of 24 (2 of each color)PTFE tubing, 1/16" OD x 0.75 mm ID x 3 metersPTFE tubing, 1/8" OD x 1/16" ID x 3 meters

Page 40: Valco Cheminert - VICI - Resolution Systems

38

SSSSS ample Lample Lample Lample Lample Loopsoopsoopsoopsoops

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

1/16" PEEK

1/16" PEEK Sample LoopsAvailable for: Valco W and UW type valves

Cheminert Models C1, C2, C2V, and C3Rheodyne metal and metal-free valves

Wide range of volumes available

Made from premium grade PEEK with tightest ID tolerance

PEEK is a mechanically strong, chemically inert polymer particularly well suited for separations involvingproteins, peptides, nucleic acids, or other samples of biological origin, as well as in IC systems wheremetal traces may interact with ioinic samples or release transition metals that can deactivate ionexchange columns. PEEK sample loops are supplied with PEEK hex-head nuts and PEEK ferrules.Softener-free PE caps are used to prevent contamination of the tubing during shipment and storage.

For Valco UW Type valves

Volume Prod No bar* psi* Price

5 µl JR-SLV-75-5 4 0 0 5800 $ 2 010 µl JR-SLV-75-10 4 0 0 5800 2020 µl JR-SLV-75-20 4 0 0 5800 2250 µl JR-SLV-75-50 4 0 0 5800 22

100 µl JR-SLV-75-100 4 0 0 5800 24250 µl JR-SLV-75-250 2 4 0 3500 34500 µl JR-SLV-75-500 2 4 0 3500 34

1 ml JR-SLV-75-1000 2 4 0 3500 44

For Cheminert® valves

Volume Prod No bar* psi* Price

5 µl JR-SLC-85-5 4 0 0 5800 $ 1 810 µl JR-SLC-85-10 4 0 0 5800 1820 µl JR-SLC-85-20 4 0 0 5800 1850 µl JR-SLC-85-50 4 0 0 5800 18

100 µl JR-SLC-85-100 4 0 0 5800 20250 µl JR-SLC-85-250 2 4 0 3500 25500 µl JR-SLC-85-500 2 4 0 3500 25

1 ml JR-SLC-85-1000 2 4 0 3500 28

For Rheodyne® valves

Volume Prod No bar* psi* Price

1 µl JR-SLR-2190 4 3 5 6300 $ 2 02 µl JR-SLR-2191 4 2 0 6100 203 µl JR-SLR-2192 4 2 0 6100 204 µl JR-SLR-2193 4 2 0 6100 20

5 µl JR-SLR-2194 4 0 0 5800 2210 µl JR-SLR-2196 4 0 0 5800 2220 µl JR-SLR-2195 3 8 6 5600 2430 µl JR-SLR-2200 3 8 6 5600 24

40 µl JR-SLR-2201 3 8 6 5600 2450 µl JR-SLR-2202 3 5 0 4500 24

100 µl JR-SLR-2204 3 5 0 4500 26200 µl JR-SLR-2206 2 4 0 3500 24

250 µl JR-SLR-2207 2 4 0 3500 28500 µl JR-SLR-2210 2 4 0 3500 34

1ml JR-SLR-2222 2 4 0 3500 46

* Recommended maximum permanent working pressure(measured with ACN/Water 1:1 at room temperature)

SPECSMaterialLoops: PEEKNuts: PEEKFerrules: PEEKCaps: Polyethylene

Tolerances± 0.025 mm (.001“)

Note:VICI Jour PEEK SampleLoops are made ofPremium Grade PEEKTubing. The tighter IDtolerance of the tubingminimizes the toleranceof the loop volume.

All PEEK sample loopsare supplied with PEEKhex-head nuts and PEEKferrules for reliableconnections.

Page 41: Valco Cheminert - VICI - Resolution Systems

0.12 mm = .005"0.25 mm = .010"0.50 mm = .020"0.75 mm = .030"

1.0 mm = .040"1.5 mm = .060"2.0 mm = .080"

4.6 mm = .180"6.0 mm = .236"6.4 mm = .253"

7.0 mm = .275"10.0 mm = .400"

1/32" = 0.8 mm1/16" = 1.6 mm1/8" = 3.2 mm

1/4" = 6.4 mm3/8" = 9.5 mm1/2" = 12.7 mm

5 cm = 1.97"10 cm = 3.94"20 cm = 7.87"30 cm = 11.82"50 cm = 19.68"

100 cm = 39.37"

39

SSSSS ample Lample Lample Lample Lample Loopsoopsoopsoopsoops

www.vici.com

1/16" Stainless Steel

1/16" Stainless Steel Sample LoopsAvailable for: Valco W and UW type valves

Cheminert Models C1, C2, C2V, and C3Rheodyne valves

Wide range of volumes available

VICI Jour stainless steel loops are made of high quality SS316, cut with an electrolytic cutting processfollowed by ultrasonic and high pressure steam cleaning. After drying, loops are capped with softener-free caps to prevent recontamination of the tubing during shipment and storage. Stainless steel loopsare supplied with SS hex-head nuts and SS ferrules for reliable connections.

For Valco UW Type valves

Volume Prod No Price

5 µl JR-SLV-76-5 $ 1 810 µl JR-SLV-76-10 1820 µl JR-SLV-76-20 1850 µl JR-SLV-76-50 18

100 µl JR-SLV-76-100 18250 µl JR-SLV-76-250 22500 µl JR-SLV-76-500 25

1 ml JR-SLV-76-1000 28

For Cheminert® valves

Volume Prod No Price

5 µl JR-SLC-86-5 $ 2 410 µl JR-SLC-86-10 2420 µl JR-SLC-86-20 2050 µl JR-SLC-86-50 20

100 µl JR-SLC-86-100 20250 µl JR-SLC-86-250 25500 µl JR-SLC-86-500 30

1 ml JR-SLC-86-1000 40

For Rheodyne® valves

Volume Prod No Price

5 µl JR-SLR-111 $ 3 010 µl JR-SLR-112 2820 µl JR-SLR-113 2850 µl JR-SLR-114 28

100 µl JR-SLR-115 28200 µl JR-SLR-116 30500 µl JR-SLR-117 34

1 ml JR-SLR-118 38

For Rheodyne® Model 7725 valves

Volume Prod No Price

5 µl JR-SLR-111-77 $ 3 010 µl JR-SLR-112-77 2820 µl JR-SLR-113-77 2850 µl JR-SLR-114-77 28

100 µl JR-SLR-115-77 28200 µl JR-SLR-116-77 30500 µl JR-SLR-117-77 34

1 ml JR-SLR-118-77 38

SPECSMaterialLoops: SS316Nuts: SS303Ferrules: SS316Caps: Polyethylene

Tolerance± 0.025 mm (.001“)

Pressure rating< 5000 psi

Note:All Loops are suppliedwith SS hex-head nutsand SS ferrules forreliable connections.

Not recommended foruse with halides. Highpressure resistance, lowpermeability.

Page 42: Valco Cheminert - VICI - Resolution Systems

40

FittingsFittingsFittingsFittingsFittings

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Cheminert® Low Pressure

TUBING NUT 1/16" COLLAPSIBLE FERRULE

1/8" COLLAPSIBLE FERRULE

Flangeless tube end fitting

Low Pressure FittingsCheminert low pressure fittings are ideally suited for flow injection analysis, low pressure liquidchromatography, and stream sampling devices. They may be safely used at pressures up to500 psi and temperatures to 50°C. Two designs of low pressure tube end fittings are available.Flangeless tube end fittings utilize our new collapsible ferrule, which grips the tubing as thefitting is tightened without significantly reducing the tube ID. Standard tube end fittings are retainedon polymeric tubing by a flange formed with a Cheminert flanging tool.

Flangeless tube end fittings

Flangeless tube end fittings eliminate the flanging toolrequired with standard tube end fittings. The nut turnson the tubing as freely as with our flanged fitting,eliminating the possibility of cracking or unscrewingthat can occur when plastic tubing is subjected totwisting as fittings are connected.

Cheminert flangeless fittings include our collapsibleferrule design (patent pending). This innovative designutilizes a one-piece ferrule engineered to collapse as itis tightened. The collapse takes place in a very narrowarea, and results in a very effective seal with virtually

no distortion of the tubing ID and no dead volume. The assembly is rated at500 psi liquid when tightened by hand. Since only the tubing and the ferrulecome into contact with the solution, the result is an inert system. Use CTFEferrules for soft tubing (PTFE, FEP, etc.), but use PEEK ferrules for hardertubing (PEEK, ETFE, polyurethane, etc.)

Cheminert tube end fittings work with any 1/16" or 1/8" OD polymerictubing, and come in twelve different colors for system color coding.

Flangeless fittings 1/16" OD 1/8" ODwith CTFE ferrules

(pkg/5) Prod No Price Prod No Price

Black CFL-1BK $ 1 0 CFL-2BK $ 1 0Blue CFL-1BE 10 CFL-2BE 10Brown CFL-1BR 10 CFL-2BR 10

Dark gray CFL-1DG 10 CFL-2DG 10Green CFL-1G 10 CFL-2G 10Lavender CFL-1L 10 CFL-2L 10

Natural CFL-1N 10 CFL-2N 10Orange CFL-1E 10 CFL-2E 10Purple CFL-1P 10 CFL-2P 10

Red CFL-1R 10 CFL-2R 10White CFL-1W 10 CFL-2W 10Yellow CFL-1Y 10 CFL-2Y 10

Assorted (pkg/12, one of each color)with ferrule:CTFE CFL-1A 20 CFL-2A 20PEEK CFL-1A-PK 20 CFL-2A-PK 20

ReplacementsPEEK ferrules (pkg/10) CFL-CB1PK 11 CFL-CB2PK 11CTFE ferrules (pkg/10) CFL-CB1KF 11 CFL-CB2KF 11PEEK nuts (pkg/5) CFL-1PK 22 CFL-2PK 22

Setting tool CST 5 CST 5

Page 43: Valco Cheminert - VICI - Resolution Systems

41

FittingsFittingsFittingsFittingsFittings

www.vici.com

Cheminert® Low Pressure

TUBING NUT WASHER FLANGE

Flanged tube end fitting

Standard flanged tube end fittings

The basic component of the Cheminert system is thepolypropylene nut, retained on PTFE or FEP tubing by aflange formed with a Cheminert flanging tool (page 88).This is an excellent method for connecting fluorocarbontubing, as there is no reduction of the inside diameterand no binding or twisting of the tubing when the fittingis tightened. A mating of the parts is achieved with zerodead volume, making this an ideal fitting for biologicalsystems.

Cheminert tube end fittings come in twelve differentcolors for system color coding, and are available for 1/16" or 1/8" ODfluorocarbon tubing. (While in theory other polymers could be molded toform a flange, only fluorocarbons such as PTFE or FEP have low-temperaturemalleability and good form retention at operating temperatures.) Tube endfittings attach directly to Cheminert valves and fittings, and are easily joinedto each other with a union. Finger-tightness is all that is required to make aleak-free seal at 500 psi liquid, although for long term reliability a wrenchcould be used to apply an additional 1/8 turn.

Packages include the same number of washers as fittings.

Flanged fittings 1/16" OD 1/8" ODProd No Price Prod No Price

Assorted (pkg/12, one of each color)CF-1A $ 1 4 CF-2A $ 1 4

Additional washers (pkg/10)CF-W1 2 CF-W2 2

Flanging tools

The flanging tool makes the flange which retains the standard tubeend fitting and washer on PTFE or FEP tubing. With this tool lengthsof tubing may be easily assembled to any required dimension. Thetime required is only 5 to 10 seconds per flange.

Flanging tools are available for 110 VAC or 230 VAC, and come completewith tips for 0.75 mm and 2.00 mm ID tubing, a tubing holder for grippingthe tubing during the flanging operation, a razor blade for tube cutting,and instructions.

Prod No Price

Flanging tools 110 VAC CFT-110 $195230 VAC CFT-220 195

Flanging tool accessoriesFlanging tips

for tubing ID ≤ 0.25 mm CFT-TXC $ 2 5for tubing ID ≤ 0.75 mm CFT-TC 25for tubing ID ≤ 1.00 mm CFT-TM 25for tubing ID ≤ 1.50 mm CFT-TL 25for tubing ID ≤ 2.00 mm CFT-TXL 25

Razor blades (pkg /10) CFT-R 5Tubing holder CFT-H 18

Page 44: Valco Cheminert - VICI - Resolution Systems

42

FittingsFittingsFittingsFittingsFittings

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Cheminert® Low Pressure

Plugs 1/4-28

Plugs can be used to close off an unused port in a 1/4-28valve or manifold.

PEEK CTFEPackage of 5: Prod No Price Prod No Price

CPPK $12 CPKF $12

PEEK plugs 10-32

These all-PEEK plugs are for use in Cheminert PEEK fittingsand low pressure polymeric valves (C20Z and C30Z series).For high pressure polymeric valves (C1-C5 series), use plugson page 48.

PEEKPackage of 1: Length of nut* Prod No Price

1/16" hex .62" MZP1PK $91/16" long hex .87" LZP1PK 91/16" fingertight .88" ZP1FPK 9

Tees 1/4-28

Includes flangeless 1/4-28 fittings.

Tubing PEEK CTFEOD Bore Prod No Price Prod No Price

1/16" 0.75 mm CTMPK $ 3 0 CTMKF $ 3 01/8" 1.50 mm CTLPK 30 CTLKF 30

Crosses 1/4-28

Includes flangeless 1/4-28 fittings.

Tubing PEEK CTFEOD Bore Prod No Price Prod No Price

1/16" 0.75 mm CXMPK $ 3 5 CXMKF $ 3 51/8" 1.50 mm CXLPK 35 CXLKF 35

Page 45: Valco Cheminert - VICI - Resolution Systems

43

FittingsFittingsFittingsFittingsFittings

www.vici.com

Cheminert® Low Pressure

Unions Cheminert to Cheminert 1/4-28 to 1/4-28

Includes flangeless 1/4-28 fittings for tubing OD indicated. Polypropyleneunions are for use with flanged tubing only.

Tubing PEEK CTFE PolypropyleneOD Bore Prod No Price Prod No Price Prod No Price

1/16" 0.50 mm CUPK $18 CUKF $18 ––– –1/16" 0.75 mm CUMPK 18 CUMKF 18 ––– –

1/8" 1.50 mm CULPK 18 CULKF 18 ––– –1/8" Butt CUTPK 15 CUTKF 15 CUTPP $8 connection (pkg/5 w/o fittings)

Bulkhead unions Cheminert to Cheminert 1/4-28 to 1/4-28

Includes flangeless 1/4-28 fittings for tubing OD indicated.

Tubing PEEK CTFE 316 StainlessOD Bore Prod No Price Prod No Price Prod No Price

1/16" 0.75 mm CBUMPK $ 2 1 CBUMKF $ 2 1 CBUMS6 $ 1 81/8" 1.50 mm CBULPK 21 CBULKF 21 CBULS6 18

Luer adapters Luer to 1/4-28

These Luer adapters with 150 mm bore make a leak-tight connection from male orfemale luer to 1/4-28 threads.

PEEK CTFE PFADescription Prod No Price Prod No Price Prod No Price

Female luer to 1/4-28 CFLAPK $15 CFLAKF $15 CFLAPFA $15Male luer to 1/4-28 CMLAPK 15 CMLAKF 15 CMLAPFA 15

Page 46: Valco Cheminert - VICI - Resolution Systems

44

FittingsFittingsFittingsFittingsFittings

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Cheminert® High Pressure

Cheminert High Pressure FIttingsThe Cheminert line of PEEK high pressure fittings is rated at 5000 psi with fingertight nuts, well beyondthe burst strength of most PEEK tubing.

Internal nuts – high pressure PEEK

PEEK nuts are used in Cheminert polymeric valves with zero dead volume fittings. They canalso be used as alternatives to standard stainless steel Valco nuts when polymeric ferrules areused (up to approximately 175°C). Fingertight nuts have a knurled surface designed to providesufficient sealing force on the ferrule without wrenches. Hex style nuts allow wrench tightening;however, since they are polymeric, they can break and are recommended for use only whenspace is limited and fingers won’t fit.

Caution: PEEK nuts are intended for use only with polymeric ferrules, which seal with lowerforce than their stainless steel counterparts. Overtightening can result in breakage.

Package of 10: Length Prod no Price

1/16" fingertight .88" ZN1FPK-10 $30

1/16" hex .45" ZN1PK-10 251/16" hex .62" MZN1PK-10 251/16" hex .87" LZN1PK-10 30

Ferrules – high pressure PEEK

PEEK ferrules seal by the increased friction from compression.

Package of 10: Prod No Price

1/16" ZF1PK-10 $30

Ferrules – grooved PEEK

These patented ferrules* feature a grooved design that permits the ferrule to gripthe tube in multiple places. They work great on tubing that is softer than theferrule material. For example, PEEK grooved ferrules work well on PTFE or FEPtubing. They are not generally recommended if the tubing is the same material asthe ferrule.

Package of 10: Prod No Price

1/16" ZGF1PK-10 $ 3 5

* Patent No. 6,575,501

PEEK plugs for high pressure polymeric valves

These PEEK plugs are for use only in Cheminert polymeric valves (C1-C5series) since the fitting detail in these valves is unique.

Description Length Prod No Priceof nut*

1/16" hex .62" C-MZP1PK $91/16" long hex .87" C-LZP1PK 91/16" fingertight .88" C-ZP1FPKL 11

Page 47: Valco Cheminert - VICI - Resolution Systems

45

FittingsFittingsFittingsFittingsFittings

www.vici.com

VICI Jour

VICI Jour PPS Hex-Head/Fingertight FittingsEconomically-priced alternative to PEEK

Excellent chemical resistance

Low pressure and high pressure versions

Slim hex head design or fingertight with Color-Sleeve adapter

The new VICI Jour PPS (polyphenylene sulfide) one-piece hex-head fitting offers excellent chemicalresistance. Available in a one-piece high pressure version with integral ferrule and 10-32 threads and alow pressure version for flat-bottomed 1/4-28 fitting details.

1/16" 1/8"

1/16" and 1/8" PPS low pressure hex head fittings 1/4-28

The low pressure version offers a choice of three sealing options:collapsible ferrule, inverted ferrule, or flanged with washer.Sold in packages of 10.

Prod No Price

Collapsible ferrule1/4-28 PPS nut for 1/16" tubing, pkg/10 JR-55050-10 $15.001/16" collapsible CTFE ferrule, pkg/10 CFL-CB1KF 11.00

1/4-28 PPS nut for 1/8" tubing, pkg/10 JR-55051-10 15.001/8" collapsible CTFE ferrule, pkg/10 CFL-CB2KF 11.00

Inverted ferrule (flangeless fitting)1/4-28 PPS nut for 1/16" tubing, pkg/10 JR-55070-10 $15.001/16" inverted ETFE ferrule, pkg/10 JR-041-10 16.00

1/4-28 PPS nut for 1/8" tubing, pkg/10 JR-55071-10 15.001/8" inverted ETFE ferrule, pkg/10 JR-051-10 16.00

Flanged fitting1/4-28 PPS nut for 1/16" tubing, pkg/10 JR-55060-10 $15.00PP washers for 1/16" flanged fitting, pkg/10 JR-201926-10 6.00

1/4-28 PPS nut for 1/8" tubing, pkg/10 JR-55061-10 15.001/8" inverted ETFE ferrule, pkg/10 JR-201928-10 6.00

1/16" PPS one piece high pressure hex head fitting 10-32

Prod No Price

Package of 5: JR-58000-5 $12.00

1/8"

1/16"

Page 48: Valco Cheminert - VICI - Resolution Systems

46

FittingsFittingsFittingsFittingsFittings

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

PEEK One-Piece Fingertight Fittings –Color-Coded and Natural

Fingertight up to 5000 psi

Excellent chemical resistance

Biocompatible

VICI Jour PEEK one-piece fittings are available in six colors tohelp identify various tubing lines. They are rated to 5000 psi,and can be used in virtually any type of 10-32 HPLC fittingdetail on the market.

1/16" PEEK one-piece fingertight fittingsMolded version

(pkg/5) Prod No Price

Natural JR-55020-5 $20.00Black JR-55021-5 20.00Red JR-55022-5 20.00

Yellow JR-55023-5 20.00Blue JR-55024-5 20.00Green JR-55025-5 20.00

VICI Jour

Color-Sleeve Fingertight AdaptersThe Color-Sleeve fingertight adapter turns the low pressureor high pressure hex head PPS fitting into a fingertight fitting,color-coded to help you distinguish various solvent lines ortubing IDs.

Color-Sleeve fingertight adapters

(pkg/5) Prod No Price

Natural JR-55080-5 $3.00White JR-55081-5 3.00Dark gray JR-55082-5 3.00

Black JR-55083-5 3.00Lavender JR-55084-5 3.00Red JR-55085-5 3.00

Yellow JR-55086-5 3.00Orange JR-55087-5 3.00Brown JR-55088-5 3.00

Green JR-55089-5 3.00Blue JR-55090-5 3.00Purple JR-55091-5 3.00

Assorted JR-5508X-24 14.40(pkg/24, one of each color)

Assorted JR-5508X-12 7.20(pkg/12, two each blue, red, green, yellow, black, and white)

Page 49: Valco Cheminert - VICI - Resolution Systems

47

Liquid HandlingLiquid HandlingLiquid HandlingLiquid HandlingLiquid Handling

www.vici.com

Micro Valves for GC and LC200 psi, .060" bore

Compact 1" design

Convenient panel mount

Variety of configurations

Simplify your liquid or gas handling application with a VICIPrecision Sampling Micro valve. The unique design of thefitting detail allows a leak-free seal with no potential for rotordamage from overtightening. Internal parts are PEEK® andPTFE.

Micro valves for GC and LC 1/4-28

Prod No Price

“T” flow path3 ports 660100 $ 7 54 ports 660110 80

180° flow path2 ports 660200 $ 7 04 ports 660210 80

90° flow path2 ports 660300 $ 7 03 ports 660310 754 ports 660320 80

SPECS200 psi.060" bore1/4-28 fitting detailAll polymer-basedmaterials

2 PORT 4 PORT

180°

2 PORT 4 PORT3 PORT

90°

4 PORT3 PORT

�T�

NEW!

Micro Valves

(Fittings not included.Order on pages 42 and 44.)

Page 50: Valco Cheminert - VICI - Resolution Systems

48

Liquid HandlingLiquid HandlingLiquid HandlingLiquid HandlingLiquid Handling

VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

Hollow Plunger SyringeHollow, flow-through plunger with integrated 3-way valve

Push button on/off valve at the front end

For liquids and gases

The new VICI Precision Sampling hollow plunger syringe (patent pending) withtwo integrated valves opens a whole new world of application possibilities:

• Dispense a viscous sample more easily by introducing it into the rear of thesyringe instead of drawing it up through the needle.

• Eliminate sample-to-sample cross contamination by giving the syringe athorough cleaning with a rinse introduced through the plunger.

• Sample continuously without ever withdrawing the needle from the originalpoint of entry. Just close the on/off valve after drawing sample through theneedle, and the sample is redirected out the plunger valve as the plunger isdepressed.

Using this syringe typically involves less plunger manipulation than doing thesame operation with a standard syringe, so you get the additional benefits ofsaved time and reduced plunger wear.

Hollow plunger syringes 100 µl - 250 µl

Prod No Price

100 µl 020025 $140250 µl 020031 1 4 0

NEW!SPECSMultivalve selection,

2-way, 3-wayRemovable needles200 psi max,

gases and liquids

6/32 UNCFEMALE THREAD

Specialized Syringes

NEW!

Syringes for Diluter/Dispensers andAutomated Instrumentation

Plunger with 6/32 UNC female thread

Accepts male end fitting on Hamilton Microlab® diluters

This plunger style works for the most common diluter/dispenser and automated robotic instrumentation. The endfitting termination is without slots.

Instrumentation syringes 250 µl - 1 ml

Prod No Price

250 µl 180031 $ 5 0500 µl 180032 50

1 ml 180033 50

PTFE TIPPEDLUER LOCK TERMINATION

Further reference

Replacementneedles ............... page 7

Page 51: Valco Cheminert - VICI - Resolution Systems

49

SupportSupportSupportSupportSupport

www.vici .com

010025 . . . . . . . . . . . . . . . . . . . . . . . 6010031 . . . . . . . . . . . . . . . . . . . . . . . 6010032 . . . . . . . . . . . . . . . . . . . . . . . 6010033 . . . . . . . . . . . . . . . . . . . . . . . 6010034 . . . . . . . . . . . . . . . . . . . . . . . 6010035 . . . . . . . . . . . . . . . . . . . . . . . 6010036 . . . . . . . . . . . . . . . . . . . . . . . 6013932 . . . . . . . . . . . . . . . . . . . . . . 12013933 . . . . . . . . . . . . . . . . . . . . . . 12013934 . . . . . . . . . . . . . . . . . . . . . . 12013935 . . . . . . . . . . . . . . . . . . . . . . 12013936 . . . . . . . . . . . . . . . . . . . . . . 12014425 . . . . . . . . . . . . . . . . . . . . . . 12014431 . . . . . . . . . . . . . . . . . . . . . . 12014432 . . . . . . . . . . . . . . . . . . . . . . 12014433 . . . . . . . . . . . . . . . . . . . . . . 12014434 . . . . . . . . . . . . . . . . . . . . . . 12014435 . . . . . . . . . . . . . . . . . . . . . . 12014436 . . . . . . . . . . . . . . . . . . . . . . 12020025 . . . . . . . . . . . . . . . . . . . . . . 48020031 . . . . . . . . . . . . . . . . . . . . . . 48030025 . . . . . . . . . . . . . . . . . . . . . . . 8030031 . . . . . . . . . . . . . . . . . . . . . . . 8030032 . . . . . . . . . . . . . . . . . . . . . . . 8030033 . . . . . . . . . . . . . . . . . . . . . . . 8030034 . . . . . . . . . . . . . . . . . . . . . . . 8030035 . . . . . . . . . . . . . . . . . . . . . . . 8030036 . . . . . . . . . . . . . . . . . . . . . . . 8030038 . . . . . . . . . . . . . . . . . . . . . . 24030039 . . . . . . . . . . . . . . . . . . . . . . 22030040 . . . . . . . . . . . . . . . . . . . . . . 22030045 . . . . . . . . . . . . . . . . . . . . . . . 8030051 . . . . . . . . . . . . . . . . . . . . . . . 8030052 . . . . . . . . . . . . . . . . . . . . . . . 8030053 . . . . . . . . . . . . . . . . . . . . . . . 8030054 . . . . . . . . . . . . . . . . . . . . . . . 8030055 . . . . . . . . . . . . . . . . . . . . . . . 8030056 . . . . . . . . . . . . . . . . . . . . . . . 8040033 . . . . . . . . . . . . . . . . . . . . . . . 9040034 . . . . . . . . . . . . . . . . . . . . . . . 9040053 . . . . . . . . . . . . . . . . . . . . . . . 9040054 . . . . . . . . . . . . . . . . . . . . . . . 9044433 . . . . . . . . . . . . . . . . . . . . . . 12044434 . . . . . . . . . . . . . . . . . . . . . . 12050023 . . . . . . . . . . . . . . . . . . . . . . . 7050024 . . . . . . . . . . . . . . . . . . . . . . . 7050025 . . . . . . . . . . . . . . . . . . . . . . . 7050031 . . . . . . . . . . . . . . . . . . . . . . . 7050032 . . . . . . . . . . . . . . . . . . . . . . . 7050033 . . . . . . . . . . . . . . . . . . . . . . . 7050034 . . . . . . . . . . . . . . . . . . . . . . . 7050035 . . . . . . . . . . . . . . . . . . . . . . . 7050036 . . . . . . . . . . . . . . . . . . . . . . . 7050039 . . . . . . . . . . . . . . . . . . . . . . 22050040 . . . . . . . . . . . . . . . . . . . . . . 22050043 . . . . . . . . . . . . . . . . . . . . . . . 7050044 . . . . . . . . . . . . . . . . . . . . . . . 7050045 . . . . . . . . . . . . . . . . . . . . . . . 7050051 . . . . . . . . . . . . . . . . . . . . . . . 7050052 . . . . . . . . . . . . . . . . . . . . . . . 7050053 . . . . . . . . . . . . . . . . . . . . . . . 7050054 . . . . . . . . . . . . . . . . . . . . . . . 7050055 . . . . . . . . . . . . . . . . . . . . . . . 7050056 . . . . . . . . . . . . . . . . . . . . . . . 7054123 . . . . . . . . . . . . . . . . . . 12, 23054124 . . . . . . . . . . . . . . . . . . 12, 23054125 . . . . . . . . . . . . . . . . . . . . . . 23060037 . . . . . . . . . . . . . . . . . . . . . . 10060039 . . . . . . . . . . . . . . . . . . . . . . 10060040 . . . . . . . . . . . . . . . . . . . . . . 10

060041 . . . . . . . . . . . . . . . . . . . . . . 10060042 . . . . . . . . . . . . . . . . . . . . . . 10060043 . . . . . . . . . . . . . . . . . . . . . . 10060044 . . . . . . . . . . . . . . . . . . . . . . 10060045 . . . . . . . . . . . . . . . . . . . . . . 10060046 . . . . . . . . . . . . . . . . . . . . . . 10060047 . . . . . . . . . . . . . . . . . . . . . . 10065037 . . . . . . . . . . . . . . . . . . . . . . 13065041 . . . . . . . . . . . . . . . . . . . . . . 13065042 . . . . . . . . . . . . . . . . . . . . . . 13065043 . . . . . . . . . . . . . . . . . . . . . . 13065437 . . . . . . . . . . . . . . . . . . . . . . 13065439 . . . . . . . . . . . . . . . . . . . . . . 13065440 . . . . . . . . . . . . . . . . . . . . . . 13065441 . . . . . . . . . . . . . . . . . . . . . . 13065442 . . . . . . . . . . . . . . . . . . . . . . 13065537 . . . . . . . . . . . . . . . . . . . . . . 13065539 . . . . . . . . . . . . . . . . . . . . . . 13065540 . . . . . . . . . . . . . . . . . . . . . . 13065541 . . . . . . . . . . . . . . . . . . . . . . 13065542 . . . . . . . . . . . . . . . . . . . . . . 13065637 . . . . . . . . . . . . . . . . . . . . . . 13065639 . . . . . . . . . . . . . . . . . . . . . . 13065640 . . . . . . . . . . . . . . . . . . . . . . 13065641 . . . . . . . . . . . . . . . . . . . . . . 13065642 . . . . . . . . . . . . . . . . . . . . . . 13065937 . . . . . . . . . . . . . . . . . . . . . . 13065939 . . . . . . . . . . . . . . . . . . . . . . 13065940 . . . . . . . . . . . . . . . . . . . . . . 13065941 . . . . . . . . . . . . . . . . . . . . . . 13065942 . . . . . . . . . . . . . . . . . . . . . . 13100010 . . . . . . . . . . . . . . . . . . . . . . 12100017 . . . . . . . . . . . . . . . . . . . . . . 12100028 . . . . . . . . . . . . . . . . . . . . . . 12100029 . . . . . . . . . . . . . . . . . . . . . . 12100042 . . . . . . . . . . . . . . . . . . . . . . 12100057 . . . . . . . . . . . . . . . . . . . . . . 12100070 . . . . . . . . . . . . . . . . . . . . . . 12100086 . . . . . . . . . . . . . . . . . . . . . . 12100100 . . . . . . . . . . . . . . . . . . . . . . 12100288 . . . . . . . . . . . . . . . . . . . . . . 13100289 . . . . . . . . . . . . . . . . . . . . . . 13100296 . . . . . . . . . . . . . . . . . . . . . . 13100297 . . . . . . . . . . . . . . . . . . . . . . 13100298 . . . . . . . . . . . . . . . . . . . . . . 13100312 . . . . . . . . . . . . . . . . . . . . . . 13100313 . . . . . . . . . . . . . . . . . . . . . . 13100320 . . . . . . . . . . . . . . . . . . . . . . 13100321 . . . . . . . . . . . . . . . . . . . . . . 13100333 . . . . . . . . . . . . . . . . . . . . . . 13100334 . . . . . . . . . . . . . . . . . . . . . . 13100341 . . . . . . . . . . . . . . . . . . . . . . 13100342 . . . . . . . . . . . . . . . . . . . . . . 13100343 . . . . . . . . . . . . . . . . . . . . . . 13100352 . . . . . . . . . . . . . . . . . . . . . . 13100353 . . . . . . . . . . . . . . . . . . . . . . 13100360 . . . . . . . . . . . . . . . . . . . . . . 13100361 . . . . . . . . . . . . . . . . . . . . . . 13100372 . . . . . . . . . . . . . . . . . . . . . . 13100373 . . . . . . . . . . . . . . . . . . . . . . 13100379 . . . . . . . . . . . . . . . . . . . . . . 13100667 . . . . . . . . . . . . . . . . . . . . . . 19100800 . . . . . . . . . . . . . . . . . . . . . . 27100826 . . . . . . . . . . . . . . . . . . . . . . 27100827 . . . . . . . . . . . . . . . . . . . . . . 27100828 . . . . . . . . . . . . . . . . . . . . . . 27100830 . . . . . . . . . . . . . . . . . . . . . . 27100838 . . . . . . . . . . . . . . . . . . . . . . 27100844 . . . . . . . . . . . . . . . . . . . . . . 27100846 . . . . . . . . . . . . . . . . . . . . . . 27

100848 . . . . . . . . . . . . . . . . . . . . . . 27100854 . . . . . . . . . . . . . . . . . . . . . . 27101430 . . . . . . . . . . . . . . . . . . . . . . . 8101440 . . . . . . . . . . . . . . . . . . . . . . . 8101448 . . . . . . . . . . . . . . . . . . . . . . . 8101455 . . . . . . . . . . . . . . . . . . . . . . . 8101463 . . . . . . . . . . . . . . . . . . . . . . . 8101470 . . . . . . . . . . . . . . . . . . . . . . . 8101478 . . . . . . . . . . . . . . . . . . . . . . . 8101935 . . . . . . . . . . . . . . . . . . . . 8, 11101989 . . . . . . . . . . . . . . . . . . . . . . 25102052 . . . . . . . . . . . . . . . . . . . . . . 25102100 . . . . . . . . . . . . . . . . . . . . . . 24102102 . . . . . . . . . . . . . . . . . . . . . . 24102103 . . . . . . . . . . . . . . . . . . . . . . 24120021 . . . . . . . . . . . . . . . . . . . . . . 15120022 . . . . . . . . . . . . . . . . . . . . . . 15120023 . . . . . . . . . . . . . . . . . . . . . . 15120024 . . . . . . . . . . . . . . . . . . . . . . 15120025 . . . . . . . . . . . . . . . . . . . . . . 15123050 . . . . . . . . . . . . . . . 14, 16, 23123050R . . . . . . . . . . . . . . . . . . . . . 20123050RT . . . . . . . . . . . . . . . . . . . 21123050WB . . . . . . . . . . . . . . . . . . . 21123721 . . . . . . . . . . . . . . . . . . . . . . 23123722 . . . . . . . . . . . . . . . . . . . . . . 23130021 . . . . . . . . . . . . . . . . . . . . . . 16130022 . . . . . . . . . . . . . . . . . . . . . . 16130221 . . . . . . . . . . . . . . . . . . . . . . 16130222 . . . . . . . . . . . . . . . . . . . . . . 16133721 . . . . . . . . . . . . . . . . . . . . . . 23133722 . . . . . . . . . . . . . . . . . . . . . . 23139022 . . . . . . . . . . . . . . . . . . . . . . 17139023 . . . . . . . . . . . . . . . . . . . . . . 17139024 . . . . . . . . . . . . . . . . . . . . . . 17139025 . . . . . . . . . . . . . . . . . . . . . . 17139124 . . . . . . . . . . . . . . . . . . . . . . 17139125 . . . . . . . . . . . . . . . . . . . . . . 17140011 . . . . . . . . . . . . . . . . . . . . . . 18140012 . . . . . . . . . . . . . . . . . . . . . . 18140021 . . . . . . . . . . . . . . . . . . . . . . 18140022 . . . . . . . . . . . . . . . . . . . . . . 18143711 . . . . . . . . . . . . . . . . . . . . . . 23143712 . . . . . . . . . . . . . . . . . . . . . . 23143721 . . . . . . . . . . . . . . . . . . . . . . 23143722 . . . . . . . . . . . . . . . . . . . . . . 23144011 . . . . . . . . . . . . . . . . . . . . . . 23144012 . . . . . . . . . . . . . . . . . . . . . . 23144021 . . . . . . . . . . . . . . . . . . . . . . 23144022 . . . . . . . . . . . . . . . . . . . . . . 23160021 . . . . . . . . . . . . . . . . . . . . . . 14160021R . . . . . . . . . . . . . . . . . . . . . 20160021RT . . . . . . . . . . . . . . . . . . . 21160021WB . . . . . . . . . . . . . . . . . . . 21160022 . . . . . . . . . . . . . . . . . . . . . . 14160022R . . . . . . . . . . . . . . . . . . . . . 20160022RT . . . . . . . . . . . . . . . . . . . 21160022WB . . . . . . . . . . . . . . . . . . . 21160023 . . . . . . . . . . . . . . . . . . . . . . 14160023R . . . . . . . . . . . . . . . . . . . . . 20160023RT . . . . . . . . . . . . . . . . . . . 21160023WB . . . . . . . . . . . . . . . . . . . 21160024 . . . . . . . . . . . . . . . . . . . . . . 14160024R . . . . . . . . . . . . . . . . . . . . . 20160024RT . . . . . . . . . . . . . . . . . . . 21160024WB . . . . . . . . . . . . . . . . . . . 21160025 . . . . . . . . . . . . . . . . . . . . . . 14160025R . . . . . . . . . . . . . . . . . . . . . 20160025RT . . . . . . . . . . . . . . . . . . . 21160025WB . . . . . . . . . . . . . . . . . . . 21

Product Number Index

160221 . . . . . . . . . . . . . . . . . . . . . . 14160221R . . . . . . . . . . . . . . . . . . . . . 20160221RT . . . . . . . . . . . . . . . . . . . 21160221WB . . . . . . . . . . . . . . . . . . . 21160222 . . . . . . . . . . . . . . . . . . . . . . 14160222R . . . . . . . . . . . . . . . . . . . . . 20160222RT . . . . . . . . . . . . . . . . . . . 21160222WB . . . . . . . . . . . . . . . . . . . 21160223 . . . . . . . . . . . . . . . . . . . . . . 14160223R . . . . . . . . . . . . . . . . . . . . . 20160223RT . . . . . . . . . . . . . . . . . . . 21160223WB . . . . . . . . . . . . . . . . . . . 21160224 . . . . . . . . . . . . . . . . . . . . . . 14160224R . . . . . . . . . . . . . . . . . . . . . 20160224RT . . . . . . . . . . . . . . . . . . . 21160224WB . . . . . . . . . . . . . . . . . . . 21160225 . . . . . . . . . . . . . . . . . . . . . . 14160225R . . . . . . . . . . . . . . . . . . . . . 20160225RT . . . . . . . . . . . . . . . . . . . 21160225WB . . . . . . . . . . . . . . . . . . . 21163721 . . . . . . . . . . . . . . . . . . . . . . 23163722 . . . . . . . . . . . . . . . . . . . . . . 23163723 . . . . . . . . . . . . . . . . . . . . . . 23163724 . . . . . . . . . . . . . . . . . . . . . . 23163725 . . . . . . . . . . . . . . . . . . . . . . 23170001 . . . . . . . . . . . . . . . . . . . . . . 19170091 . . . . . . . . . . . . . . . . . . . . . . 19180031 . . . . . . . . . . . . . . . . . . . . . . 48180032 . . . . . . . . . . . . . . . . . . . . . . 48180033 . . . . . . . . . . . . . . . . . . . . . . 48220005 . . . . . . . . . . . . . . . . . . . . . . 26220011 . . . . . . . . . . . . . . . . . . . . . . 26220012 . . . . . . . . . . . . . . . . . . . . . . 26220021 . . . . . . . . . . . . . . . . . . . . . . 26220022 . . . . . . . . . . . . . . . . . . . . . . 26220311 . . . . . . . . . . . . . . . . . . . . . . 27220312 . . . . . . . . . . . . . . . . . . . . . . 27220315 . . . . . . . . . . . . . . . . . . . . . . 27220321 . . . . . . . . . . . . . . . . . . . . . . 27220322 . . . . . . . . . . . . . . . . . . . . . . 27220344 . . . . . . . . . . . . . . . . . . . . . . 27220347 . . . . . . . . . . . . . . . . . . . . . . 27220351 . . . . . . . . . . . . . . . . . . . . . . 27220352 . . . . . . . . . . . . . . . . . . . . . . 27230051 . . . . . . . . . . . . . . . . . . . . . . 27230250 . . . . . . . . . . . . . . . . . . . . . . 27240040 . . . . . . . . . . . . . . . . . . . . . . 26240041 . . . . . . . . . . . . . . . . . . . . . . 26240042 . . . . . . . . . . . . . . . . . . . . . . 26240043 . . . . . . . . . . . . . . . . . . . . . . 26500031 . . . . . . . . . . . . . . . . . . . . . . 30500076 . . . . . . . . . . . . . . . . . . . . . . 25500081 . . . . . . . . . . . . . . . . . . . . . . 25500084 . . . . . . . . . . . . . . . . . . . . . . 25500088 . . . . . . . . . . . . . . . . . . . . . . 25500090 . . . . . . . . . . . . . . . . . . . . . . 25500100 . . . . . . . . . . . . . . . . . . . . . . 30500301 . . . . . . . . . . . . . . . . . . . . . . 30500335 . . . . . . . . . . . . . . . . . . . . . . 30500441 . . . . . . . . . . . . . . . . . . . . . . 30500523 . . . . . . . . . . . . . . . . . . . . . . 30500635 . . . . . . . . . . . . . . . . . . . . . . 13500994 . . . . . . . . . . . . . . . . . . . . . . 25501040 . . . . . . . . . . . . . . . . . . . . . . 25501064 . . . . . . . . . . . . . . . . . . . . . . 25501071 . . . . . . . . . . . . . . . . . . . . . . 25501072 . . . . . . . . . . . . . . . . . . . . . . 25501073 . . . . . . . . . . . . . . . . . . . . . . 25501092 . . . . . . . . . . . . . . . . . . . . . . 25502743 . . . . . . . . . . . . . . . . . . . . . . 25

Page 52: Valco Cheminert - VICI - Resolution Systems

50

SupportSupportSupportSupportSupport

www.vici .com VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–926–4631 Email: [email protected]

JR-SLR-115 . . . . . . . . . . . . . . . . . . . 39JR-SLR-115-77 . . . . . . . . . . . . . . . 39JR-SLR-116 . . . . . . . . . . . . . . . . . . . 39JR-SLR-116-77 . . . . . . . . . . . . . . . 39JR-SLR-117 . . . . . . . . . . . . . . . . . . . 39JR-SLR-117-77 . . . . . . . . . . . . . . . 39JR-SLR-118 . . . . . . . . . . . . . . . . . . . 39JR-SLR-118-77 . . . . . . . . . . . . . . . 39JR-SLR-2190 . . . . . . . . . . . . . . . . . 38JR-SLR-2191 . . . . . . . . . . . . . . . . . 38JR-SLR-2192 . . . . . . . . . . . . . . . . . 38JR-SLR-2193 . . . . . . . . . . . . . . . . . 38JR-SLR-2194 . . . . . . . . . . . . . . . . . 38JR-SLR-2195 . . . . . . . . . . . . . . . . . 38JR-SLR-2196 . . . . . . . . . . . . . . . . . 38JR-SLR-2200 . . . . . . . . . . . . . . . . . 38JR-SLR-2201 . . . . . . . . . . . . . . . . . 38JR-SLR-2202 . . . . . . . . . . . . . . . . . 38JR-SLR-2204 . . . . . . . . . . . . . . . . . 38JR-SLR-2206 . . . . . . . . . . . . . . . . . 38JR-SLR-2207 . . . . . . . . . . . . . . . . . 38JR-SLR-2210 . . . . . . . . . . . . . . . . . 38JR-SLR-2222 . . . . . . . . . . . . . . . . . 38JR-SLV-75-10 . . . . . . . . . . . . . . . . . 38JR-SLV-75-100 . . . . . . . . . . . . . . . . 38JR-SLV-75-1000 . . . . . . . . . . . . . . 38JR-SLV-75-20 . . . . . . . . . . . . . . . . . 38JR-SLV-75-250 . . . . . . . . . . . . . . . . 38JR-SLV-75-5 . . . . . . . . . . . . . . . . . . 38JR-SLV-75-50 . . . . . . . . . . . . . . . . . 38JR-SLV-75-500 . . . . . . . . . . . . . . . . 38JR-SLV-76-5 . . . . . . . . . . . . . . . . . . 39JR-SLV-76-10 . . . . . . . . . . . . . . . . . 39JR-SLV-76-100 . . . . . . . . . . . . . . . . 39JR-SLV-76-1000 . . . . . . . . . . . . . . 39JR-SLV-76-20 . . . . . . . . . . . . . . . . . 39JR-SLV-76-250 . . . . . . . . . . . . . . . . 39JR-SLV-76-50 . . . . . . . . . . . . . . . . . 39JR-SLV-76-500 . . . . . . . . . . . . . . . . 39JR-T-5999-F10 . . . . . . . . . . . . . . . 35JR-T-5999-F25 . . . . . . . . . . . . . . . 35JR-T-5999-F5 . . . . . . . . . . . . . . . . . 35JR-T-6000-F10 . . . . . . . . . . . . . . . 35JR-T-6000-F25 . . . . . . . . . . . . . . . 35JR-T-6000-F5 . . . . . . . . . . . . . . . . . 35JR-T-6001-F10 . . . . . . . . . . . . . . . 35JR-T-6001-F25 . . . . . . . . . . . . . . . 35JR-T-6001-F5 . . . . . . . . . . . . . . . . . 35JR-T-6002-F10 . . . . . . . . . . . . . . . 35JR-T-6002-F25 . . . . . . . . . . . . . . . 35JR-T-6002-F5 . . . . . . . . . . . . . . . . . 35JR-T-60031-F10 . . . . . . . . . . . . . . 35JR-T-60031-F25 . . . . . . . . . . . . . . 35JR-T-60031-F5 . . . . . . . . . . . . . . . 35JR-T-60032-F10 . . . . . . . . . . . . . . 35JR-T-60032-F25 . . . . . . . . . . . . . . 35JR-T-60032-F5 . . . . . . . . . . . . . . . 35JR-T-6003-F10 . . . . . . . . . . . . . . . 35JR-T-6003-F25 . . . . . . . . . . . . . . . 35JR-T-6003-F5 . . . . . . . . . . . . . . . . . 35JR-T-6007-F10 . . . . . . . . . . . . . . . 35JR-T-6007-F25 . . . . . . . . . . . . . . . 35JR-T-6007-F5 . . . . . . . . . . . . . . . . . 35JR-T-6008-F10 . . . . . . . . . . . . . . . 35JR-T-6008-F25 . . . . . . . . . . . . . . . 35JR-T-6008-F5 . . . . . . . . . . . . . . . . . 35JR-T-6009-F10 . . . . . . . . . . . . . . . 35JR-T-6009-F25 . . . . . . . . . . . . . . . 35JR-T-6009-F5 . . . . . . . . . . . . . . . . . 35JR-T-6010-F10 . . . . . . . . . . . . . . . 35

502968 . . . . . . . . . . . . . . . . . . . . . . 24502971 . . . . . . . . . . . . . . . . . . . . . . 31503188 . . . . . . . . . . . . . . . . . . . . . . 25503840 . . . . . . . . . . . . . . . . . . . . . . 31505032 . . . . . . . . . . . . . . . . . . . . . . 31505118 . . . . . . . . . . . . . . . . . . . . . . 31505193 . . . . . . . . . . . . . . . . . . . . . . 31505490 . . . . . . . . . . . . . . . . . . . . . . 31505491 . . . . . . . . . . . . . . . . . . . . . . 31505739 . . . . . . . . . . . . . . . . . . . . . . 31505741 . . . . . . . . . . . . . . . . . . . . . . 31505828 . . . . . . . . . . . . . . . . . . . . . . 31505829 . . . . . . . . . . . . . . . . . . . . . . 31505830 . . . . . . . . . . . . . . . . . . . . . . 31505831 . . . . . . . . . . . . . . . . . . . . . . 31614158 . . . . . . . . . . . . . . . . . . . . . . 28614160 . . . . . . . . . . . . . . . . . . . . . . 28614161 . . . . . . . . . . . . . . . . . . . . . . 28614163 . . . . . . . . . . . . . . . . . . . . . . 28614170 . . . . . . . . . . . . . . . . . . . . . . 28614250 . . . . . . . . . . . . . . . . . . . . . . 28621102 . . . . . . . . . . . . . . . . . . . . . . 29621103 . . . . . . . . . . . . . . . . . . . . . . 29631201 . . . . . . . . . . . . . . . . . . . . . . 29631202 . . . . . . . . . . . . . . . . . . . . . . 29631203 . . . . . . . . . . . . . . . . . . . . . . 29631204 . . . . . . . . . . . . . . . . . . . . . . 29631205 . . . . . . . . . . . . . . . . . . . . . . 29631206 . . . . . . . . . . . . . . . . . . . . . . 29644350 . . . . . . . . . . . . . . . . . . . . . . 29644850 . . . . . . . . . . . . . . . . . . . . . . 29654050 . . . . . . . . . . . . . . . . . . . . 9, 29654051 . . . . . . . . . . . . . . . . . . . . 9, 29660100 . . . . . . . . . . . . . . . . . . . . . . 47660110 . . . . . . . . . . . . . . . . . . . . . . 47660200 . . . . . . . . . . . . . . . . . . . . . . 47660210 . . . . . . . . . . . . . . . . . . . . . . 47660300 . . . . . . . . . . . . . . . . . . . . . . 47660310 . . . . . . . . . . . . . . . . . . . . . . 47660320 . . . . . . . . . . . . . . . . . . . . . . 47913050 . . . . . . . . . . . . . . . . . . . . 6, 11913052 . . . . . . . . . . . . . . . . . . . . 6, 11923011 . . . . . . . . . . . . . . . . . . 18, 23923012 . . . . . . . . . . . . . . . . . . 18, 23923021 . . . . . . . . . . . . . . . . . . 18, 23923022 . . . . . . . . . . . . . . . . . . 18, 23943050 . . . . . . . . . . . . . . . . . 7, 8, 11943051 . . . . . . . . . . . . . . . . . 7-9, 11943052 . . . . . . . . . . . . . . . . . 7, 9, 11943060 . . . . . . . . . . . . . . . . . . . . 7, 11943061 . . . . . . . . . . . . . . 7, 9, 11, 22943062 . . . . . . . . . . . . . . . . . 7, 9, 11953050 . . . . . . . . . . . . . . . . . . 10, 11953052 . . . . . . . . . . . . . . . . . . 10, 11953061 . . . . . . . . . . . . . . . . . . 10, 11953062 . . . . . . . . . . . . . . . . . . 10, 11CBULKF . . . . . . . . . . . . . . . . . . . . . . 43CBULPK . . . . . . . . . . . . . . . . . . . . . . 43CBULS6 . . . . . . . . . . . . . . . . . . . . . . 43CBUMKF . . . . . . . . . . . . . . . . . . . . . 43CBUMPK . . . . . . . . . . . . . . . . . . . . . 43CBUMS6 . . . . . . . . . . . . . . . . . . . . . 43CF-1A . . . . . . . . . . . . . . . . . . . . . . . . 41CF-2A . . . . . . . . . . . . . . . . . . . . . . . . 41CFL-1A . . . . . . . . . . . . . . . . . . . . . . . 40CFL-1A-PK . . . . . . . . . . . . . . . . . . . 40CFL-1BE . . . . . . . . . . . . . . . . . . . . . . 40CFL-1BK . . . . . . . . . . . . . . . . . . . . . . 40CFL-1BR . . . . . . . . . . . . . . . . . . . . . . 40CFL-1DG . . . . . . . . . . . . . . . . . . . . . 40

CFL-1E . . . . . . . . . . . . . . . . . . . . . . . 40CFL-1G . . . . . . . . . . . . . . . . . . . . . . . 40CFL-1L . . . . . . . . . . . . . . . . . . . . . . . 40CFL-1N . . . . . . . . . . . . . . . . . . . . . . . 40CFL-1P . . . . . . . . . . . . . . . . . . . . . . . 40CFL-1PK . . . . . . . . . . . . . . . . . . . . . . 40CFL-1R . . . . . . . . . . . . . . . . . . . . . . . 40CFL-1W . . . . . . . . . . . . . . . . . . . . . . 40CFL-1Y . . . . . . . . . . . . . . . . . . . . . . . 40CFL-2A . . . . . . . . . . . . . . . . . . . . . . . 40CFL-2A-PK . . . . . . . . . . . . . . . . . . . 40CFL-2BE . . . . . . . . . . . . . . . . . . . . . . 40CFL-2BK . . . . . . . . . . . . . . . . . . . . . . 40CFL-2BR . . . . . . . . . . . . . . . . . . . . . . 40CFL-2DG . . . . . . . . . . . . . . . . . . . . . 40CFL-2E . . . . . . . . . . . . . . . . . . . . . . . 40CFL-2G . . . . . . . . . . . . . . . . . . . . . . . 40CFL-2L . . . . . . . . . . . . . . . . . . . . . . . 40CFL-2N . . . . . . . . . . . . . . . . . . . . . . . 40CFL-2P . . . . . . . . . . . . . . . . . . . . . . . 40CFL-2PK . . . . . . . . . . . . . . . . . . . . . . 40CFL-2R . . . . . . . . . . . . . . . . . . . . . . . 40CFL-2W . . . . . . . . . . . . . . . . . . . . . . 40CFL-2Y . . . . . . . . . . . . . . . . . . . . . . . 40CFLAKF . . . . . . . . . . . . . . . . . . . . . . 43CFLAPFA . . . . . . . . . . . . . . . . . . . . . 43CFLAPK . . . . . . . . . . . . . . . . . . . . . . 43CFL-CB1KF . . . . . . . . . . . . . . . 40, 45CFL-CB1PK . . . . . . . . . . . . . . . . . . . 40CFL-CB2KF . . . . . . . . . . . . . . . 40, 45CFL-CB2PK . . . . . . . . . . . . . . . . . . . 40CFT-110 . . . . . . . . . . . . . . . . . . . . . . 41CFT-220 . . . . . . . . . . . . . . . . . . . . . . 41CFT-H . . . . . . . . . . . . . . . . . . . . . . . . 41CFT-R . . . . . . . . . . . . . . . . . . . . . . . . . 41CFT-TC . . . . . . . . . . . . . . . . . . . . . . . 41CFT-TL . . . . . . . . . . . . . . . . . . . . . . . 41CFT-TM . . . . . . . . . . . . . . . . . . . . . . . 41CFT-TXC . . . . . . . . . . . . . . . . . . . . . . 41CFT-TXL . . . . . . . . . . . . . . . . . . . . . . 41CF-W1 . . . . . . . . . . . . . . . . . . . . . . . . 41CF-W2 . . . . . . . . . . . . . . . . . . . . . . . . 41C-LZP1PK . . . . . . . . . . . . . . . . . . . . 44CMLAKF . . . . . . . . . . . . . . . . . . . . . 43CMLAPFA . . . . . . . . . . . . . . . . . . . . 43CMLAPK . . . . . . . . . . . . . . . . . . . . . 43C-MZP1PK . . . . . . . . . . . . . . . . . . . 44CPKF . . . . . . . . . . . . . . . . . . . . . . . . . 42CPPK . . . . . . . . . . . . . . . . . . . . . . . . . 42CST . . . . . . . . . . . . . . . . . . . . . . . . . . . 40CTLKF . . . . . . . . . . . . . . . . . . . . . . . . 42CTLPK . . . . . . . . . . . . . . . . . . . . . . . . 42CTMKF . . . . . . . . . . . . . . . . . . . . . . . 42CTMPK . . . . . . . . . . . . . . . . . . . . . . . 42CUKF . . . . . . . . . . . . . . . . . . . . . . . . . 43CULKF . . . . . . . . . . . . . . . . . . . . . . . . 43CULPK . . . . . . . . . . . . . . . . . . . . . . . 43CUMKF . . . . . . . . . . . . . . . . . . . . . . . 43CUMPK . . . . . . . . . . . . . . . . . . . . . . . 43CUPK . . . . . . . . . . . . . . . . . . . . . . . . . 43CUTKF . . . . . . . . . . . . . . . . . . . . . . . . 43CUTPK . . . . . . . . . . . . . . . . . . . . . . . 43CUTPP . . . . . . . . . . . . . . . . . . . . . . . 43CXLKF . . . . . . . . . . . . . . . . . . . . . . . . 42CXLPK . . . . . . . . . . . . . . . . . . . . . . . . 42CXMKF . . . . . . . . . . . . . . . . . . . . . . . 42CXMPK . . . . . . . . . . . . . . . . . . . . . . . 42C-ZP1FPKL . . . . . . . . . . . . . . . . . . . 44JR-041-10 . . . . . . . . . . . . . . . . . . . . 45JR-051-10 . . . . . . . . . . . . . . . . . . . . 45

JR-201531 . . . . . . . . . . . . . . . . . . . 37JR-201536 . . . . . . . . . . . . . . . . . . . 37JR-201537 . . . . . . . . . . . . . . . . . . . 37JR-201539 . . . . . . . . . . . . . . . . . . . 37JR-201540 . . . . . . . . . . . . . . . . . . . 37JR-201541 . . . . . . . . . . . . . . . . . . . 37JR-201554 . . . . . . . . . . . . . . . . . . . 37JR-201662 . . . . . . . . . . . . . . . . . . . 37JR-201663 . . . . . . . . . . . . . . . . . . . 37JR-201926-10 . . . . . . . . . . . . . . . . 45JR-201928-10 . . . . . . . . . . . . . . . . 45JR-202235 . . . . . . . . . . . . . . . . . . . 37JR-357090 . . . . . . . . . . . . . . . . . . . 36JR-357180 . . . . . . . . . . . . . . . . . . . 36JR-55020-5 . . . . . . . . . . . . . . . . . . 46JR-55021-5 . . . . . . . . . . . . . . . . . . 46JR-55022-5 . . . . . . . . . . . . . . . . . . 46JR-55023-5 . . . . . . . . . . . . . . . . . . 46JR-55024-5 . . . . . . . . . . . . . . . . . . 46JR-55025-5 . . . . . . . . . . . . . . . . . . 46JR-55050-10 . . . . . . . . . . . . . . . . . 45JR-55051-10 . . . . . . . . . . . . . . . . . 45JR-55060-10 . . . . . . . . . . . . . . . . . 45JR-55061-10 . . . . . . . . . . . . . . . . . 45JR-55070-10 . . . . . . . . . . . . . . . . . 45JR-55071-10 . . . . . . . . . . . . . . . . . 45JR-55080-5 . . . . . . . . . . . . . . . . . . 46JR-55081-5 . . . . . . . . . . . . . . . . . . 46JR-55082-5 . . . . . . . . . . . . . . . . . . 46JR-55083-5 . . . . . . . . . . . . . . . . . . 46JR-55084-5 . . . . . . . . . . . . . . . . . . 46JR-55085-5 . . . . . . . . . . . . . . . . . . 46JR-55086-5 . . . . . . . . . . . . . . . . . . 46JR-55087-5 . . . . . . . . . . . . . . . . . . 46JR-55088-5 . . . . . . . . . . . . . . . . . . 46JR-55089-5 . . . . . . . . . . . . . . . . . . 46JR-5508X-12 . . . . . . . . . . . . . . . . . 46JR-5508X-24 . . . . . . . . . . . . . . . . . 46JR-55090-5 . . . . . . . . . . . . . . . . . . 46JR-55091-5 . . . . . . . . . . . . . . . . . . 46JR-58000-5 . . . . . . . . . . . . . . . . . . 45JR-794 . . . . . . . . . . . . . . . . . . . . . . . 36JR-795 . . . . . . . . . . . . . . . . . . . . . . . 36JR-797 . . . . . . . . . . . . . . . . . . . 36, 37JR-798 . . . . . . . . . . . . . . . . . . . . . . . 36JR-9001 . . . . . . . . . . . . . . . . . . . . . . 36JR-SLC-85-10 . . . . . . . . . . . . . . . . . 38JR-SLC-85-100 . . . . . . . . . . . . . . . 38JR-SLC-85-1000 . . . . . . . . . . . . . . 38JR-SLC-85-20 . . . . . . . . . . . . . . . . . 38JR-SLC-85-250 . . . . . . . . . . . . . . . 38JR-SLC-85-5 . . . . . . . . . . . . . . . . . . 38JR-SLC-85-50 . . . . . . . . . . . . . . . . . 38JR-SLC-85-500 . . . . . . . . . . . . . . . 38JR-SLC-86-10 . . . . . . . . . . . . . . . . . 39JR-SLC-86-100 . . . . . . . . . . . . . . . 39JR-SLC-86-1000 . . . . . . . . . . . . . . 39JR-SLC-86-20 . . . . . . . . . . . . . . . . . 39JR-SLC-86-250 . . . . . . . . . . . . . . . 39JR-SLC-86-5 . . . . . . . . . . . . . . . . . . 39JR-SLC-86-50 . . . . . . . . . . . . . . . . . 39JR-SLC-86-500 . . . . . . . . . . . . . . . 39JR-SLR-111 . . . . . . . . . . . . . . . . . . . 39JR-SLR-111-77 . . . . . . . . . . . . . . . 39JR-SLR-112 . . . . . . . . . . . . . . . . . . . 39JR-SLR-112-77 . . . . . . . . . . . . . . . 39JR-SLR-113 . . . . . . . . . . . . . . . . . . . 39JR-SLR-113-77 . . . . . . . . . . . . . . . 39JR-SLR-114 . . . . . . . . . . . . . . . . . . . 39JR-SLR-114-77 . . . . . . . . . . . . . . . 39

Product Number Index

Page 53: Valco Cheminert - VICI - Resolution Systems

51

SupportSupportSupportSupportSupport

www.vici .com

Product Number Index

JR-T-6010-F25 . . . . . . . . . . . . . . . 35JR-T-6010-F5 . . . . . . . . . . . . . . . . . 35JR-T-6011-F10 . . . . . . . . . . . . . . . 35JR-T-6011-F25 . . . . . . . . . . . . . . . 35JR-T-6011-F5 . . . . . . . . . . . . . . . . . 35LZN1PK-10 . . . . . . . . . . . . . . . . . . . 44LZP1PK . . . . . . . . . . . . . . . . . . . . . . 42MZN1PK-10 . . . . . . . . . . . . . . . . . . 44MZP1PK . . . . . . . . . . . . . . . . . . . . . 42T100C10-10 . . . . . . . . . . . . . . . . . 33T100C10-100 . . . . . . . . . . . . . . . . 33T100C10-50 . . . . . . . . . . . . . . . . . 33T100C10D . . . . . . . . . . . . . . . . . . . 33T100C20-10 . . . . . . . . . . . . . . . . . 33T100C20-100 . . . . . . . . . . . . . . . . 33T100C20-50 . . . . . . . . . . . . . . . . . 33T100C20D . . . . . . . . . . . . . . . . . . . 33T100C30-10 . . . . . . . . . . . . . . . . . 33T100C30-100 . . . . . . . . . . . . . . . . 33T100C30-50 . . . . . . . . . . . . . . . . . 33T100C30D . . . . . . . . . . . . . . . . . . . 33T100 C40-10 . . . . . . . . . . . . . . . . . 33T100C40-100 . . . . . . . . . . . . . . . . 33T100C40-50 . . . . . . . . . . . . . . . . . 33T100C40D . . . . . . . . . . . . . . . . . . . 33T100C5-10 . . . . . . . . . . . . . . . . . . . 33T100C5-100 . . . . . . . . . . . . . . . . . 33T100C5-50 . . . . . . . . . . . . . . . . . . . 33T100C5D . . . . . . . . . . . . . . . . . . . . . 33T100N10-10 . . . . . . . . . . . . . . . . . 32T100N10-100 . . . . . . . . . . . . . . . . 32T100N10-50 . . . . . . . . . . . . . . . . . 32T100N10D . . . . . . . . . . . . . . . . . . . 32T100N20-10 . . . . . . . . . . . . . . . . . 32T100N20-100 . . . . . . . . . . . . . . . . 32T100N20-50 . . . . . . . . . . . . . . . . . 32T100N20D . . . . . . . . . . . . . . . . . . . 32T100N5-10 . . . . . . . . . . . . . . . . . . . 32T100N5-100 . . . . . . . . . . . . . . . . . 32T100N5-50 . . . . . . . . . . . . . . . . . . . 32T100N5D . . . . . . . . . . . . . . . . . . . . 32T10C10-10 . . . . . . . . . . . . . . . . . . . 33T10C10-100 . . . . . . . . . . . . . . . . . 33T10C10-50 . . . . . . . . . . . . . . . . . . . 33T10C10D . . . . . . . . . . . . . . . . . . . . . 33T10C20-10 . . . . . . . . . . . . . . . . . . . 33T10C20-100 . . . . . . . . . . . . . . . . . 33T10C20-50 . . . . . . . . . . . . . . . . . . . 33T10C20D . . . . . . . . . . . . . . . . . . . . . 33T10C30-10 . . . . . . . . . . . . . . . . . . . 33T10C30-100 . . . . . . . . . . . . . . . . . 33T10C30-50 . . . . . . . . . . . . . . . . . . . 33T10C30D . . . . . . . . . . . . . . . . . . . . . 33T10C40-10 . . . . . . . . . . . . . . . . . . . 33T10C40-100 . . . . . . . . . . . . . . . . . 33T10C40-50 . . . . . . . . . . . . . . . . . . . 33T10C40D . . . . . . . . . . . . . . . . . . . . . 33T10C5-10 . . . . . . . . . . . . . . . . . . . . 33T10C5-100 . . . . . . . . . . . . . . . . . . . 33T10C5-50 . . . . . . . . . . . . . . . . . . . . 33T10C5D . . . . . . . . . . . . . . . . . . . . . . 33T10N10-10 . . . . . . . . . . . . . . . . . . . 32T10N10-100 . . . . . . . . . . . . . . . . . 32T10N10-50 . . . . . . . . . . . . . . . . . . . 32T10N10D . . . . . . . . . . . . . . . . . . . . 32T10N20-10 . . . . . . . . . . . . . . . . . . . 32T10N20-100 . . . . . . . . . . . . . . . . . 32T10N20-50 . . . . . . . . . . . . . . . . . . . 32T10N20D . . . . . . . . . . . . . . . . . . . . 32T10N5-10 . . . . . . . . . . . . . . . . . . . . 32

T10N5-100 . . . . . . . . . . . . . . . . . . . 32T10N5-50 . . . . . . . . . . . . . . . . . . . . 32T10N5D . . . . . . . . . . . . . . . . . . . . . . 32T20C10-10 . . . . . . . . . . . . . . . . . . . 33T20C10-100 . . . . . . . . . . . . . . . . . 33T20C10-50 . . . . . . . . . . . . . . . . . . . 33T20C10D . . . . . . . . . . . . . . . . . . . . . 33T20C20-10 . . . . . . . . . . . . . . . . . . . 33T20C20-100 . . . . . . . . . . . . . . . . . 33T20C20-50 . . . . . . . . . . . . . . . . . . . 33T20C20D . . . . . . . . . . . . . . . . . . . . . 33T20C30-10 . . . . . . . . . . . . . . . . . . . 33T20C30-100 . . . . . . . . . . . . . . . . . 33T20C30-50 . . . . . . . . . . . . . . . . . . . 33T20C30D . . . . . . . . . . . . . . . . . . . . . 33T20C40-10 . . . . . . . . . . . . . . . . . . . 33T20C40-100 . . . . . . . . . . . . . . . . . 33T20C40-50 . . . . . . . . . . . . . . . . . . . 33T20C40D . . . . . . . . . . . . . . . . . . . . . 33T20C5-10 . . . . . . . . . . . . . . . . . . . . 33T20C5-100 . . . . . . . . . . . . . . . . . . . 33T20C5-50 . . . . . . . . . . . . . . . . . . . . 33T20C5D . . . . . . . . . . . . . . . . . . . . . . 33T20N10-10 . . . . . . . . . . . . . . . . . . . 32T20N10-100 . . . . . . . . . . . . . . . . . 32T20N10-50 . . . . . . . . . . . . . . . . . . . 32T20N10D . . . . . . . . . . . . . . . . . . . . 32T20N20-10 . . . . . . . . . . . . . . . . . . . 32T20N20-100 . . . . . . . . . . . . . . . . . 32T20N20-50 . . . . . . . . . . . . . . . . . . . 32T20N20D . . . . . . . . . . . . . . . . . . . . 32T20N5-10 . . . . . . . . . . . . . . . . . . . . 32T20N5-100 . . . . . . . . . . . . . . . . . . . 32T20N5-50 . . . . . . . . . . . . . . . . . . . . 32T20N5D . . . . . . . . . . . . . . . . . . . . . . 32T30C10-10 . . . . . . . . . . . . . . . . . . . 33T30C10-100 . . . . . . . . . . . . . . . . . 33T30C10-50 . . . . . . . . . . . . . . . . . . . 33T30C10D . . . . . . . . . . . . . . . . . . . . . 33T30C20-10 . . . . . . . . . . . . . . . . . . . 33T30C20-100 . . . . . . . . . . . . . . . . . 33T30C20-50 . . . . . . . . . . . . . . . . . . . 33T30C20D . . . . . . . . . . . . . . . . . . . . . 33T30C30-10 . . . . . . . . . . . . . . . . . . . 33T30C30-100 . . . . . . . . . . . . . . . . . 33T30C30-50 . . . . . . . . . . . . . . . . . . . 33T30C30D . . . . . . . . . . . . . . . . . . . . . 33T30C40-10 . . . . . . . . . . . . . . . . . . . 33T30C40-100 . . . . . . . . . . . . . . . . . 33T30C40-50 . . . . . . . . . . . . . . . . . . . 33T30C40D . . . . . . . . . . . . . . . . . . . . . 33T30C5-10 . . . . . . . . . . . . . . . . . . . . 33T30C5-100 . . . . . . . . . . . . . . . . . . . 33T30C5-50 . . . . . . . . . . . . . . . . . . . . 33T30C5D . . . . . . . . . . . . . . . . . . . . . . 33T30N10-10 . . . . . . . . . . . . . . . . . . . 32T30N10-100 . . . . . . . . . . . . . . . . . 32T30N10-50 . . . . . . . . . . . . . . . . . . . 32T30N10D . . . . . . . . . . . . . . . . . . . . 32T30N20-10 . . . . . . . . . . . . . . . . . . . 32T30N20-100 . . . . . . . . . . . . . . . . . 32T30N20-50 . . . . . . . . . . . . . . . . . . . 32T30N20D . . . . . . . . . . . . . . . . . . . . 32T30N5-10 . . . . . . . . . . . . . . . . . . . . 32T30N5-100 . . . . . . . . . . . . . . . . . . . 32T30N5-50 . . . . . . . . . . . . . . . . . . . . 32T30N5D . . . . . . . . . . . . . . . . . . . . . . 32T50C10-10 . . . . . . . . . . . . . . . . . . . 33T50C10-100 . . . . . . . . . . . . . . . . . 33T50C10-50 . . . . . . . . . . . . . . . . . . . 33

T50C10D . . . . . . . . . . . . . . . . . . . . . 33T50C20-10 . . . . . . . . . . . . . . . . . . . 33T50C20-100 . . . . . . . . . . . . . . . . . 33T50C20-50 . . . . . . . . . . . . . . . . . . . 33T50C20D . . . . . . . . . . . . . . . . . . . . . 33T50C30-10 . . . . . . . . . . . . . . . . . . . 33T50C30-100 . . . . . . . . . . . . . . . . . 33T50C30-50 . . . . . . . . . . . . . . . . . . . 33T50C30D . . . . . . . . . . . . . . . . . . . . . 33T50C40-10 . . . . . . . . . . . . . . . . . . . 33T50C40-100 . . . . . . . . . . . . . . . . . 33T50C40-50 . . . . . . . . . . . . . . . . . . . 33T50C40D . . . . . . . . . . . . . . . . . . . . . 33T50C5-10 . . . . . . . . . . . . . . . . . . . . 33T50C5-100 . . . . . . . . . . . . . . . . . . . 33T50C5-50 . . . . . . . . . . . . . . . . . . . . 33T50C5D . . . . . . . . . . . . . . . . . . . . . . 33T50N10-10 . . . . . . . . . . . . . . . . . . . 33T50N10-100 . . . . . . . . . . . . . . . . . 32T50N10-50 . . . . . . . . . . . . . . . . . . . 32T50N10D . . . . . . . . . . . . . . . . . . . . 32T50N20-10 . . . . . . . . . . . . . . . . . . . 32T50N20-100 . . . . . . . . . . . . . . . . . 32T50N20-50 . . . . . . . . . . . . . . . . . . . 32T50N20D . . . . . . . . . . . . . . . . . . . . 32T50N5-10 . . . . . . . . . . . . . . . . . . . . 32T50N5-100 . . . . . . . . . . . . . . . . . . . 32T50N5-50 . . . . . . . . . . . . . . . . . . . . 32T50N5D . . . . . . . . . . . . . . . . . . . . . . 32T5C10-10 . . . . . . . . . . . . . . . . . . . . 33T5C10-100 . . . . . . . . . . . . . . . . . . . 33T5C10-50 . . . . . . . . . . . . . . . . . . . . 33T5C10D . . . . . . . . . . . . . . . . . . . . . . 33T5C20-10 . . . . . . . . . . . . . . . . . . . . 33T5C20-100 . . . . . . . . . . . . . . . . . . . 33T5C20-50 . . . . . . . . . . . . . . . . . . . . 33T5C20D . . . . . . . . . . . . . . . . . . . . . . 33T5C30-10 . . . . . . . . . . . . . . . . . . . . 33T5C30-100 . . . . . . . . . . . . . . . . . . . 33T5C30-50 . . . . . . . . . . . . . . . . . . . . 33T5C30D . . . . . . . . . . . . . . . . . . . . . . 33T5C40-10 . . . . . . . . . . . . . . . . . . . . 33T5C40-100 . . . . . . . . . . . . . . . . . . . 33T5C40-50 . . . . . . . . . . . . . . . . . . . . 33T5C40D . . . . . . . . . . . . . . . . . . . . . . 33T5C5-10 . . . . . . . . . . . . . . . . . . . . . 33T5C5-100 . . . . . . . . . . . . . . . . . . . . 33T5C5-50 . . . . . . . . . . . . . . . . . . . . . 33T5C5D . . . . . . . . . . . . . . . . . . . . . . . 33T5N10-10 . . . . . . . . . . . . . . . . . . . . 32T5N10-100 . . . . . . . . . . . . . . . . . . . 32T5N10-50 . . . . . . . . . . . . . . . . . . . . 32T5N10D . . . . . . . . . . . . . . . . . . . . . . 32T5N20-10 . . . . . . . . . . . . . . . . . . . . 32T5N20-100 . . . . . . . . . . . . . . . . . . . 32T5N20-50 . . . . . . . . . . . . . . . . . . . . 32T5N20D . . . . . . . . . . . . . . . . . . . . . . 32T5N5-10 . . . . . . . . . . . . . . . . . . . . . 32T5N5-100 . . . . . . . . . . . . . . . . . . . . 32T5N5-50 . . . . . . . . . . . . . . . . . . . . . 32T5N5D . . . . . . . . . . . . . . . . . . . . . . . 32TFEP110 . . . . . . . . . . . . . . . . . . . . . 34TFEP120 . . . . . . . . . . . . . . . . . . . . . 34TFEP130 . . . . . . . . . . . . . . . . . . . . . 34TFEP260 . . . . . . . . . . . . . . . . . . . . . 34THC130 . . . . . . . . . . . . . . . . . . . . . . 34THC270 . . . . . . . . . . . . . . . . . . . . . . 34TNI.507 . . . . . . . . . . . . . . . . . . . . . . 34TNI.510 . . . . . . . . . . . . . . . . . . . . . . 34TNI.520 . . . . . . . . . . . . . . . . . . . . . . 34

TNI105 . . . . . . . . . . . . . . . . . . . . . . . 34TNI110 . . . . . . . . . . . . . . . . . . . . . . . 34TNI120 . . . . . . . . . . . . . . . . . . . . . . . 34TNI130 . . . . . . . . . . . . . . . . . . . . . . . 34TNI140 . . . . . . . . . . . . . . . . . . . . . . . 34TNI285 . . . . . . . . . . . . . . . . . . . . . . . 34TPK106 . . . . . . . . . . . . . . . . . . . . . . 34TPK110 . . . . . . . . . . . . . . . . . . . . . . 34TPK120 . . . . . . . . . . . . . . . . . . . . . . 34TPK130 . . . . . . . . . . . . . . . . . . . . . . 34TPK260 . . . . . . . . . . . . . . . . . . . . . . 34TSS.505 . . . . . . . . . . . . . . . . . . . . . . 34TSS.507 . . . . . . . . . . . . . . . . . . . . . . 34TSS.510 . . . . . . . . . . . . . . . . . . . . . . 34TSS.520 . . . . . . . . . . . . . . . . . . . . . . 34TSS105 . . . . . . . . . . . . . . . . . . . . . . . 34TSS110 . . . . . . . . . . . . . . . . . . . . . . . 34TSS115 . . . . . . . . . . . . . . . . . . . . . . . 34TSS120 . . . . . . . . . . . . . . . . . . . . . . . 34TSS126 . . . . . . . . . . . . . . . . . . . . . . . 34TSS130 . . . . . . . . . . . . . . . . . . . . . . . 34TSS140 . . . . . . . . . . . . . . . . . . . . . . . 34TSS230 . . . . . . . . . . . . . . . . . . . . . . . 34TSS240 . . . . . . . . . . . . . . . . . . . . . . . 34TSS260 . . . . . . . . . . . . . . . . . . . . . . . 34TSS267 . . . . . . . . . . . . . . . . . . . . . . . 34TSS285 . . . . . . . . . . . . . . . . . . . . . . . 34TTF106 . . . . . . . . . . . . . . . . . . . . . . . 34TTF110 . . . . . . . . . . . . . . . . . . . . . . . 34TTF115 . . . . . . . . . . . . . . . . . . . . . . . 34TTF120 . . . . . . . . . . . . . . . . . . . . . . . 34TTF130 . . . . . . . . . . . . . . . . . . . . . . . 34TTF140 . . . . . . . . . . . . . . . . . . . . . . . 34TTF230 . . . . . . . . . . . . . . . . . . . . . . . 34TTF260 . . . . . . . . . . . . . . . . . . . . . . . 34TTF285 . . . . . . . . . . . . . . . . . . . . . . . 34TTI112 . . . . . . . . . . . . . . . . . . . . . . . 34TTI120 . . . . . . . . . . . . . . . . . . . . . . . 34TTI131 . . . . . . . . . . . . . . . . . . . . . . . 34TTZ110 . . . . . . . . . . . . . . . . . . . . . . 34TTZ120 . . . . . . . . . . . . . . . . . . . . . . 34TTZ130 . . . . . . . . . . . . . . . . . . . . . . 34TTZ260 . . . . . . . . . . . . . . . . . . . . . . 34ZF1PK-10 . . . . . . . . . . . . . . . . . . . . 44ZGF1PK-10 . . . . . . . . . . . . . . . . . . . 44ZN1FPK-10 . . . . . . . . . . . . . . . . . . . 44ZN1PK-10 . . . . . . . . . . . . . . . . . . . . 44ZP1FPK . . . . . . . . . . . . . . . . . . . . . . 42

Page 54: Valco Cheminert - VICI - Resolution Systems

SupportSupportSupportSupportSupport

52 VICI Precision Sampling Inc. Sales: 800–828–1653 Fax: 225–923–1331 Email: [email protected]

SupportSupportSupportSupportSupport

UNITED STATES, CENTRALand SOUTH AMERICA,JAPAN, AUSTRALIA, andNEW ZEALAND

VICI PRECISION SAMPLING

Phone: (800) 828-1653(225) 927-1128

Fax: (225) 926-4631(225) 923-1331

Email: [email protected]

VICI Precision Sampling, Inc.P.O. Box 15886Baton Rouge, LA 70895-5886

F.O.B. shipping point, our factory,Baton Rouge, Louisiana.

We accept:

To order

EUROPE, AFRICA,MIDDLE EAST, andASIA (except Japan)

VICI AG INTERNATIONAL

Phone: Int + 41- 41- 925-6200Fax: Int + 41- 41- 925-6201Email: [email protected]

Parkstrasse 2CH-6214 SchenkonSwitzerland

F.O.B. shipping point, our factory,Schenkon, Switzerland.

We accept:

CANADA

VICI VALCO INSTRUMENTSCANADA CORPORATION

Phone: (866) 297-2626(613) 342-2600

Fax: (613) 342-0111Email: [email protected]

26 Water Street EastBrockville, OntraioCanada K6V 1A1

F.O.B. shipping point, our factory,Brockville, Canada.

We accept:

Conditions of SaleOur terms are net 30 days.F.O. B. shipping, our factory,

Baton Rouge, LA.Prices subject to change without

notice.All prices are in U.S. dollars.

Repairs/Technical SupportFor information about factoryrefurbishment or for assistancewith your technical questions andapplication needs, contact ourSales Department.

Phone: (225) 927-1128Fax: (225) 926-4631Email: [email protected]

NoticeVICI reserves the right to correcterrors and change prices, designs,or specifictions without notice orliability. The information in thiscatalog is correct to the best ofour knowledge but is not guar-anteed to be so. VICI assumesno responsibility with respectthereto.

ReturnsNo returns will be accepted morethan 90 days after shipment forany reason. Before 90 days, noreturns will be accepted withoutprior authorization. If it is necess-ary to return material to us, pleasecontact our Sales Department for areturn authorization number andforwarding instructions. Inspectshipments upon receipt and reportshortages or incorrect or damagedmaterial to us immediately.

Important!Damaged shipments must remainwith the original packaging forfreight company inspection.

Returned material will be subjectto a minimum restocking fee of15% for catalog items. Specialorders cannot be returned unlessdefective.

WarrantyVICI Precision Sampling warrantsall products we manufacture to befree from defects in material and/or workmanship for thirty daysfrom the time of receipt by thecustomer.VICI Precision Sampling´s liabilityfor defects in material or work-manship shall be limited toreplacement of the defective itemat no charge to the customer, orrefund of the purchase price paid.Bending, breakage, or otherdamage resulting from shippingis not a warranty issue; a claimshould be filed with the shippingcompany. This warranty is in lieuof any other warranties, expressedor implied, including but notlimited to any warranty of fitnessfor purpose or any warranty ofmerchantability. Copies of anywritten warranty pertaining toproducts shown in this catalogmanufactured by a company otherthan VICI Precision Sampling canbe obtained upon written request.

52

Ordering Information

Page 55: Valco Cheminert - VICI - Resolution Systems

SupportSupportSupportSupportSupport

www.vici .com

TRADEMARKSCheminert Valco Instruments Co. Inc.

and VICI AGHamilton HamiltonHastelloy C Haynes InternationalMicro-Flo Valco Instruments Co. Inc.Microlab HamiltonMininert Valco Instruments Co. Inc.PEEK VictrexPerkin Elmer Perkin Elmer Inc.Pressure-Flo Valco Instruments Co. Inc.Pressure-Lok Valco Instruments Co. Inc.Rheodyne RheodyneRyton Phillips Petroleum Co.Varian Varian AssociatesVICI Valco Instruments Co. Inc.

and VICI AGWaters Waters Associates

Page 56: Valco Cheminert - VICI - Resolution Systems

©2006 by VICI Precision Sampling, Inc.

VICI Precision Sampling, Inc.P.O. Box 15886Baton Rouge, LA 70895-5886

Phone: (800) 828-1653(225) 927-1128

Fax: (225) 926-4631(225) 923-1331

Email: [email protected]