Modern Rulesfor an Old Practice:
Sensor Placement for GxP Temperature Mapping
Paul Daniel
Senior Regulatory Compliance Expert
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
2/89
Page 2 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Challenges with your audio connection? Try calling toll-free: 866-740-1260
Other technical challenges?
Try logging in to webinar again.
Participate by:
Answering poll questions.
Ask questions using “Chat” function.
You will receive a link to the presentation in email.
Practical Webinar Stuff
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
3/89
Page 3 / Sensor Placement for GxP Temperature Mapping – © Vaisala
I need to do a mapping study.
I need to review a mapping study.
Professional Development.
I had an hour to kill…
Why are you here?
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
4/89
Page 4 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Warehouses
Coldrooms
Refrigerators
Freezers
Incubators
Stability Chambers
POLL 1: What kind of environments areyou interested in mapping?
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
5/89
Page 5 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Pharmaceuticals
Medical Devices
Biologics
Nutriceuticals
Consulting Firm
Student
Other
POLL 2: What kind of company do youwork for?
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
6/89
Page 6 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Yes
No
I’m not sure…
POLL 3: Is your organization a Vaisalacustomer?
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
7/89
Page 7 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Vaisala team
Speaker:
Paul Daniel
Sr. Regulatory Compliance Expert
Chat operator:
Janice Livingston
Marketing Manager
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
8/89
Page 8 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Vaisala in Brief
We serve customers in weather and controlledenvironment markets
80 years of experience in providing a comprehensiverange of innovative observation and measurement
products and services
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
9/89
Page 9 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Vaisala - Life Science
Our Goal is to help customers
• Reduce their risk of lost or
adulterated product
• Reduce their risk of failing to meet
GxP regulations and/or guidelines
Our Offering
Provides measurement instrumentation, continuous monitoring systems and
validation systems for regulated or highly controlled life science
environments.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
10/89
Page 10 / Sensor Placement for GxP Temperature Mapping – © Vaisala
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
11/89
Page 11 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Health Canada
– GUI-0069 – Guidelines for Temperature Control of
Drug Products during Storage and Transportation
ISPE
–
Good Practice Guide: Cold Chain Management
Recent History
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
12/89
Page 12 / Sensor Placement for GxP Temperature Mapping – © Vaisala
PDA
– Technical Report 58 – Risk Management for
Temperature Controlled Distribution
CDSCO (India)
–
Guidelines on Good Distribution Practice for BiologicalProducts
Recent History
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
13/89
Page 13 / Sensor Placement for GxP Temperature Mapping – © Vaisala
CFDA (China)
– Good Supply Practices for Pharmaceutical Products
EMA (Europe)
– (2013/C 68/01) Good Distribution Practice of Medicinal
Products for Human Use
USP 36 – Chapter Good Storage and Distribution
Practices for Drug Products
Recent History
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
14/89
Page 14 / Sensor Placement for GxP Temperature Mapping – © Vaisala
EMA (Europe)
– Ref Ares(2014)968163 – 28/03/2014 Good Distribution
Practice of Medicinal Products for Human Use –
Questions and Answers – Version 1
PIC/S
– PIC/S Guide to Good Distribution Practice for Medicinal
Products
– Note: Nothing new. Identical to EU GDP.
Recent History
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
15/89
Page 15 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Review Mapping Regulations.
Discuss 5 Rules for Sensor Placement.
Review Current Guidance on Sensor Placement.
Goals
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
16/89
Page 16 / Sensor Placement for GxP Temperature Mapping – © Vaisala
The regulations don’t tell us how to map, or even to map.
Regulatory Summary
1. Determine if environmental parameters affect product quality.
2. Do stability testing to determine appropriate storage specifications.3. Ensure that storage spaces are controlled to meet specifications.
Mapping and monitoring is industry GMP response to #3.
Therefore, regulations aren’t very helpful for sensor placement!
Regulations and Mapping
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
17/89
Page 17 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Tradition and Precedence
What has been done at your facility before?
Equipment What equipment do you already have?
Science
What makes sense based on scientific principles?
Guidance
Resources for Sensor Placement
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
18/89
Page 18 / Sensor Placement for GxP Temperature Mapping – © Vaisala
5 Rules
Map the Extremes.
Map in 3 Dimensions.
For Large Spaces, Map Storage Only.
Identify and Address Variables.
If it’s worth mapping, its worth monitoring.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
19/89
Page 19 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 1: Map the Extremes.
Geometric Place sensors at each end of the storage area.
Conditions
Apply validation principle of worst cases.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
20/89
Page 20 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Parts of a Cube
Corner – 3 planes
Edge – 2 planes
Side – 1 plane
Space – 0 planes
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
21/89
Page 21 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Parts of a Cube
Corner – 3 planes
Space – 0 planes
Rule 1: Map the Extremes
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
22/89
Page 22 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Corollary 1A: If ≤ 2m3, use 9 + 1.
TOP
FRONT
SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
23/89
Page 23 / Sensor Placement for GxP Temperature Mapping – © Vaisala
9 spots = worst case?
Air Flow:
Corners have least air circulation.
Center has most air circulation.
Heat Exchange:
Corners have the most exposure (3 planes)
Center has the least exposure (0 planes)
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
24/89
Page 24 / Sensor Placement for GxP Temperature Mapping – © Vaisala
How many? Where? < 20m3
TOP
FRONT SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
25/89
Page 25 / Sensor Placement for GxP Temperature Mapping – © Vaisala
How many? Where? < 20m3TOP
FRONT
SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
26/89
Page 26 / Sensor Placement for GxP Temperature Mapping – © Vaisala
How many? Where? < 20m3TOP
FRONT
SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
27/89
Page 27 / Sensor Placement for GxP Temperature Mapping – © Vaisala
How many? Where? < 20m3TOP
FRONT
SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
28/89
Page 28 / Sensor Placement for GxP Temperature Mapping – © Vaisala
How many? Where? < 20m3TOP
FRONT
SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
29/89
Page 29 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Corollary 1B: If ≤ 20m3, use 15 +1.
TOP
FRONT
SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
30/89
Page 30 / Sensor Placement for GxP Temperature Mapping – © Vaisala
ISPE Good Practice Guide: Cold Chain Management (2011)
Guidance describes 9 +1 and 15 +1
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
31/89
Page 31 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 2: Map in 3 Dimensions.
3 planes.
Left to right.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
32/89
Page 32 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 2: Map in 3 Dimensions.
3 planes.
Top to bottom.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
33/89
Page 33 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 2: Map in 3 Dimensions.
3 planes.
Front to back.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
34/89
Page 34 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Corollary 2A: If ≥ 20m3, use Stacks of 3.
High
Middle
Low
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
35/89
Page 35 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Stacks of 3, in 3 dimensions.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
36/89
Page 36 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Stacks of 3, in 3 dimensions.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
37/89
Page 37 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Stacks of 3, in 3 dimensions.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
38/89
Page 38 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Stacks of 3, in 3 dimensions.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
39/89
Page 39 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Stacks of 3, in 3 dimensions.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
40/89
Page 40 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Corollary 2A: If ≥ 20m3, use Stacks of 3.
High
Middle
Low
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
41/89
Page 41 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Corollary 2B: Remove sensors if possible.
Remove “extra” sensors.
15 +1 diagram. With “Stacks of 3, in 3-D”,
it would have 27 sensors.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
42/89
Page 42 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Stacks of 3, in 3 dimensions.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
43/89
Page 43 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Stacks of 3, in 3 dimensions.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
44/89
Page 44 / Sensor Placement for GxP Temperature Mapping – © Vaisala
“Completing a three-dimensional temperature profile shouldbe achieved by measuring points at not less than three
dimensional planes in each direction/axis—top-to-bottom,
left-to-right, front-to-back…”
USP 36 Chapter Good Storage and Distribution
Practices for Drug Products (2013)
More published support....
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
45/89
Page 45 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 3: If ≥ 20m3, map storage only.
As the space gets larger, it is not necessary to map hallways
and access areas.
Map only the shelves and areas
where product is actually stored.
Requires controls to prevent
storage in wrong areas.
SOPs
Training
Signs
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
46/89
Page 46 / Sensor Placement for GxP Temperature Mapping – © Vaisala
“Completing a three-dimensional temperature profile shouldbe achieved by measuring points at not less than three
dimensional planes in each direction/axis—top-to-bottom,
left-to-right, front-to-back, where product will be present.”
USP 36 Chapter Good Storage and Distribution
Practices for Drug Products (2013)
More published support....
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
47/89
Page 47 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 1 – Map the Extremes Corollary 1A – If ≤ 2m3, use 9+1.
Corollary 1B – If ≤ 20m3, use 15+1
Rule Summary (so far…)
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
48/89
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
49/89
Page 49 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 1 – Map the Extremes Corollary 1A – If ≤ 2m3, use 9+1.
Corollary 1B – If ≤ 20m3, use 15+1
Rule 2 - Map in 3 Dimensions Corollary 2A – If ≤ 20m3, use Stacks of 3
Corollary 2B – Remove Sensors if Possible
Rule 3 - If ≥ 20m3, map storage only.
Rule Summary (so far…)
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
50/89
Page 50 / Sensor Placement for GxP Temperature Mapping – © Vaisala
“…additional points may be needed depending on airflow
sources/characteristics, shelving (storage locations), external
temperature sources, and previous experience with similar
units and their thermal behavior.”
– ISPE Good Practice Guide: Cold Chain Management (2011)
It’s just guidance. It’s a place to start.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
51/89
Page 51 / Sensor Placement for GxP Temperature Mapping – © Vaisala
The following factors should be considered during
temperature mapping of storage locations:
Size of the space
HVAC Locations
Sun-facing walls Low ceilings or roofs
Geography
Airflow
Outside temperature variability
Weekly workflow variation
Equipment movement Storage patterns of product
Equipment capabilities
SOPs.
More from USP 36 Chapter ...
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
52/89
Page 52 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 4: Identify Variables
VolumeTemperature ∆
Height
Exterior Walls
Construction Materials
Doors and Windows
Lighting
Gradients
HVAC Vents and Returns Air Circulation
Control Sensors
Energy Sources
Racks and Shelving
Traffic Patterns
Human Factors
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
53/89
Page 53 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Volume
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
54/89
Page 54 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Temperature ∆
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
55/89
Page 55 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Height
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
56/89
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
57/89
Page 57 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Construction Materials
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
58/89
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
59/89
Page 59 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Lighting
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
60/89
Page 60 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Gradients
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
61/89
Page 61 / Sensor Placement for GxP Temperature Mapping – © Vaisala
HVAC Vents and Returns
C
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
62/89
Page 62 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Air Circulation
C l S
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
63/89
Page 63 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Control Sensors
E S
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
64/89
Page 64 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Energy Sources
R k Sh l d P d t
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
65/89
Page 65 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Racks, Shelves, and Product
T ffi P tt
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
66/89
Page 66 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Traffic Patterns
H F t
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
67/89
Page 67 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Human Factors
R l 4 Id tif V i bl
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
68/89
Page 68 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 4: Identify Variables
Place sensors nearrepresentative variables!
Adjust ideal “grid” to intersect
variables.
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
69/89
Page 69 / Sensor Placement for GxP Temperature Mapping – © Vaisala
TOP
FRONT (South Wall)
SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
70/89
Page 70 / Sensor Placement for GxP Temperature Mapping – © Vaisala
TOP
FRONT (South Wall)
SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
71/89
Page 71 / Sensor Placement for GxP Temperature Mapping – © Vaisala
TOP
FRONT (South Wall)
SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
72/89
Page 72 / Sensor Placement for GxP Temperature Mapping – © Vaisala
TOP
FRONT (South Wall)
SIDE
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
73/89
Page 73 / Sensor Placement for GxP Temperature Mapping – © Vaisala
TOP
FRONT (South Wall)
SIDE
Distance Between Points
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
74/89
Page 74 / Sensor Placement for GxP Temperature Mapping – © Vaisala
T e m p e r a
t u r e
Distance (X)
Distance Between Points
Distance Between Points
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
75/89
Page 75 / Sensor Placement for GxP Temperature Mapping – © Vaisala
T e m p e r a
t u r e
Distance (X)
Distance Between Points
Distance Between Points
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
76/89
Page 76 / Sensor Placement for GxP Temperature Mapping – © Vaisala
T e m p e r a
t u r e
Distance (1/2X)
Distance Between Points
Distance Between Points
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
77/89
Page 77 / Sensor Placement for GxP Temperature Mapping – © Vaisala
T e m p e r a
t u r e
Distance (1/2X)
Distance Between Points
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
78/89
Distance Between Points
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
79/89
Page 79 / Sensor Placement for GxP Temperature Mapping – © Vaisala
T e m p e r a
t u r e
Distance (1/8X)
Distance Between Points
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
80/89
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
81/89
Page 81 / Sensor Placement for GxP Temperature Mapping – © Vaisala
TOP
FRONT (North Wall)
SIDE
Rule 5: If it is worth mapping
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
82/89
Page 82 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 5: If it is worth mapping…It is worth monitoring.
Find the hot and cold spots and monitor them.
Select the right monitoring solution.
Qualify the monitoring system.
Monitoring
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
83/89
Page 83 / Sensor Placement for GxP Temperature Mapping – © Vaisala
“Temperature monitoring… documents the temperatures
during the qualification and operation. It allows conclusions onwhether the product is stored and shipped within the approved
temperature range. Therefore, an appropriate temperature
monitoring strategy should be selected and qualified.”
PDA Technical Report No. 58: Risk Management for
Temperature Controlled Distribution (2012)
Monitoring....
Rule Summary
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
84/89
Page 84 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Rule 1 – Map the Extremes
Corollary 1A – If ≤ 2m3, use 9+1.
Corollary 1B – If ≤ 20m3, use 15+1
Rule 2 - Map in 3 Dimensions
Corollary 2A – If ≤ 20m3, use Stacks of 3
Corollary 2B – Remove Sensors if Possible
Rule 3 - If ≥ 20m3, map storage only.
Rule 4 – Identify Variables
Rule 5 – If it is worth Mapping, it is worth Monitoring
Rule Summary
What about product temperature?
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
85/89
Page 85 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Its always best to measure air temperature. Worst case scenario provides best challenge.
“It is normal practice to use air temperature as the reference
source for the stored [product]…” and is ‘the worst
case representation of the stored product
temperatures.”
-ISPE Good Practice Guide:
Cold Chain Management (2011)
What about product temperature?
What about mapping humidity?
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
86/89
Page 86 / Sensor Placement for GxP Temperature Mapping – © Vaisala
The same concepts apply, but concerned with sources of moisture.
Use the same number of sensors unless you have an expert who
understands humidity theory.
“Where relative humidity is a critical factor, then humidity sensors could be
located in the same locations – or fewer locations used with the impact of thetemperature considered for other locations – as absolute
humidity will be very similar throughout the space.”
-ISPE Good Practice Guide:
Cold Chain Management (2011)
What about mapping humidity?
POLL 4:
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
87/89
Page 87 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Yes, I’m interested in… Loggers
Yes, I’m interested in… Validation Mapping Kit
Yes, I’m interested in… Mapping Services
Yes, I’m interested in… Continuous Monitoring System
Yes, I’m interested in… Process Instrumentation
Yes, I’m interested in… Handheld devices
Yes, I’m interested in… Other
No, thanks.
POLL 4:Do you want Vaisala to contact you?
Summary
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
88/89
Page 88 / Sensor Placement for GxP Temperature Mapping – © Vaisala
Reviewed Mapping Regulations.
Explored 5 Rules for Sensor Placement for Mapping Storage Areas.
Reviewed Mapping Guidance.
Summary
Thanks for Attending!
8/17/2019 Vaisala Webinar GxP Sensor Placement Rules 2016
89/89
Paul Daniel
Senior Regulatory Compliance Expert
Vaisala, Inc.
Email: [email protected]