Vacuum RegulatorTop Mounted
Selector
Large, easy to read display
Adjustable Timing
Flexible ABS Polymerfor Durability
Intermittent - Grey Label Continuous - White Label
Ease of Inventory Management
• By Department: ED Pediatrics ICU
Ease of Model Identification
• Identify by Treatment: OR/Continuous High Pediatrics Continuous/Intermittent Neonatal
Color Coding Options
Features:
• Smallest and lightest unit on the market: 10oz (290g)
• ABS polymer casing – impact resistant and durable
• User-adjustable Timing
• Easy to read, color-coded gauges
• 10 Year warranty (Analog)
• 12 Year warranty (Digital)
• Only unit on the market with a disposable see-through back body
• Designed with Infection Control features
Unit
Front Back
Infection Control Made Easy
Disposable Body
Step 1:
Step 3:
Step 2:
Contaminated ?
Studies have shown that although there is a belief thatcleaning removes contamination, there is evidence to suggest that in fact it doesn’t. Since sterilization is not guaranteed to remove all bacteria, the safest course of action is to replace the contaminated portion of the regulator.
Suction Regulators: A Potential Vector for Hospital -Acquired Pathogens ‘Keith S. Kaye, MD, MPH; Dror Marchaim, MD; Chester Smialowicz, MD; Lauren Bentley, MSBME
CONTAMINATED CONTAMINATED
Did You Know ?
Reassemble with only 1 NEW Component
Easy Modular Design
Easy to Upgrade:
Analog to Digital
Continuous to Continuous/Intermittent
Accessories:
Disposable CanistersModel Number: SRX-TRP Model Number: SRX-TRP-DH
Vacuum/Safety Traps Canisters
Canister Holder
→
→
→
→
Technical Specifications
Model NumberSRX-XXXX-XXX
Vacuum Regulator Type
CI = Continuous/Intermittent
C2 = Continuous 2 Mode
C3 = Continuous 3 Mode
CH = Continuous High
PI = Pediatric/Intermittent
P2 = Pediatric 2 Mode
NI = Neonatal/Intermittent
N2 = Neonatal 2 Mode
Inlet Connection
F2 = 1/8” FNPT
DH = DISS Handtight
DN = DISS Nut
OM = Ohmeda Male
CM = Chemetron Male
PB = Puritan Bennett
MS = Medstar
OX = Oxequip
BM = British Male
GM = German Male (DIN)
DO = DISS Outlet
Color Coding
U = USA
I = International
**Color Coding
R = Red
B = Blue
G = Green
P = Purple
Y = Yellow
N = Pink
Z = Baby Blue
A = Analog
D = Digital
Patient Connection
2 = 1/8” FNPT
D = DISS Male
T = Tubing Nipple
Performance
Flowrate Intermittent:
Continuous:
Adult: 8 LPM
Adult: 65 LPM
Pediatric: 8 LPM Neonatal: 8 LPM
Pediatric: 40 LPM Neonatal: 40 LPM
Timing: • 16 seconds on/ 8 seconds off• Timing can be adjusted on the back of the unit with access to ON and OFF needle valves • Starts in the OFF position
Gauge Accuracy:
Neonatal:
Pediatric:
Adult:
Surgical:
0-100 mmHG
0-160 mmHG
0-300 mmHG
0-750 mmHG
Analog
± 3% Full-scale
± 3% Full-scale
± 3% Full-scale
± 3% Full-scale
Digital
± 1% Full-scale
± 1% Full-scale
± 1% Full-scale
± 1% Full-scale
Physical
Dimensions: 5.94” H x 2.93” W x 4.04” D(15.09 cm x 7.44 cm x 10.26 cm)
Weight: Continuous: 10 oz (290 g) Intermittent: 13 oz (360 g)
Lithium:
*Vacuum Range:
* For MRI compatible please add “M” to the end of the part number (only available in continuous models)** If no color is specified white is the standard*** Vacuum traps available: SRX-TRP (no fitting)
Two 2/3 AA batteries, 3.6 V, 1.6 Ah, lithium
Continuous High/ Surgical: 0 - 750 mmHg (94 KPA)Continuous and Continuous/ Intermittent: 0 - 300 mmHg (40 KPA)Pediatric and Pediatric/ Intermittent: 0 - 160 mmHg (20 KPA)NeoNatal and NeoNatal/Intermittent: 0 - 100 mmHg (13 KPA)
Battery
Analog to Digital
Amico Patient Care Equipment Corporation 20 Sims, Unit 1, Richmond Hill, ON L4B 2N9, CanadaToll Free Tel: 1.877.462.6426 | Toll Free Fax:1.866.440.4986 | Tel: 905.764.0800 | Fax: 905.764.0862