vacon ac drivescomfort & control in hvac
2
save money and the environment
Today’s buildings are sophisticated systems with demanding comfort and control requirements. A typical offi ce building has a large number of pumps and fans for heating, ventilation and air conditioning. Together, with high energy effi ciency and comfort demands, this leads to a need for advanced control features, but also for high reliability. Vacon AC drives combine these require-ments in an easy to use package.
Vacon offers a complete and well-recognized range of AC drives for building automation. Vacon drives can substantial-ly improve the quality and effi ciency of the building’s heating, ventilation and air-conditioning systems.
Saves The Environment
The protection of nature and environment has become an increasing global concern for our society. The pressureon the environment is increasing all the time and action is needed to redirect this otherwise adverse trend towards a more sustainable goal. The AC drive helps to increase the energy effi ciency of a building and thus uses the existing en-ergy resources more effi ciently.
Energy Saving Calculators
How much money and energy can be saved? Energy Saving Calculators are available on the Vacon web site: www.vacon.com. The payback time of an AC drive is usually around one year in HVAC systems.
3
can be used everywhere
Fans
• Supply and extract ventilation fans• Variable Air Volume VAV systems• Constant Air Volume CAV systems• Cooling tower fans• Condenser fans• Boiler fans• Car park ventilation fans• Stairway ventilation
Pumps
• Chilling• Heating• Booster• Pressuration set• Cold and hot water pumps• Cooling tower pumps• Delta P regulation on heat exchangers• Swimming pool pumps
Compressors
• Chilling• Clean air compressors• Gas compressors• Heat pumps
4
The well packaged hardware combined with user friendly software makes Vacon NX the preferred solution for HVAC. The visually guided start-up function ensures that the Vacon AC drive will be fully operational after a few keypresses.
easy to set up
Start-up wizard –fastest and easiest setup with the keypad
Vacon NXL drives come with a special 4-step start-up wizard, which makes it possible to set up basic pump and fan applica-tions in only a few seconds. All instructions can be found in the Vacon NXL quick guide.
The Vacon NXS comprehensive wizard guides you through the setup so that all the necessary start-up parameters and set-tings are determined.
Vacon PC tool –fastest and easiest setup with the PC
The Vacon NCDrive tool offers an easy way to save and confi g-ure the drive settings.
Advantage NXS NXL
Start-up Wizard x x
Motor Auto-Identifi cation x x
Parameter Copy with Keypad x
Parameter Copy with PC x x
Local Language x
Easy Local - Remote Select x x
Multi Monitor x
Panel Light x x
5
The mechanical design is extremely compact. The IP54 units in particular are among the smallest AC drives in the market. All units are suitable for both wall and enclosure mounting with all neces-sary components integrated: EMC fi lters, input chokes, cable protection, dust and water protec-tion. The effective super-cooling principle allows high ambient temperatures and high switching frequencies without derating.
the best features
Fieldbus options:
• Modbus RTU • Metasys N2• LonWorks• BACnet• Modbus/TCP (Ethernet)• Profi bus DP• CANopen• DeviceNet
Separate control unit
Removable display panel
Separated cooling channel(no electronics in air fl ow)
Easily replaceable,temperature-controlledcooling fan
Integrated input choke as standard
Easy to access power terminalsunder the protective plate
Integrated EMC fi lters as standard
Easily confi gurable and versatile I/O to meet all requirements
Power unit fully enclosed in metal
Advantage NXS NXL
Protection classes IP21 and IP54 x x
Modular Design x x
Separated Cooling Channel x x
Temperature Controlled Fan x x
Easily Replaceable Fan x x
Input Chokes as Standard x x
Integrated EMC Filters x x
Option Board Slots 5 pcs 2 pcs
Fieldbus Options x x
RS485 as Standard x
6
Advantage NXS NXL
Open Loop Vector Cotrol x x
150 % Starting Torque x x
Standard Switching Frequency 10 kHz 6 kHz
Vacon Flying Start x x
Prohibit Frequency Ranges 3 ranges 1 range
Overtemperature Ride Through x x
Power Loss Ride Through x x
Auto-Restart Function x x
Motor DC Heating x x
True Output Switching x x
Prohibit frequency ranges -no resonances
Any resonance in the system can be avoided by overriding the critical frequencies.
High switching frequency –low motor noise
Near sinusoidal motor current and extremely low noise is reached because of the advanced motor control and high pulse frequency.
Vacon Flying start –best in performance
Flying start allows the fan or pump to start smoothly if the shaft is already rotating when the drive is started. The Vacon NX syncronizes itself to the motor quickly and reliably, and ad-justs the speed to the reference value.
Triples operation –reliable system
Vacon NX AC drives are designed to achieve trip free operation even in abnormal situations.• Overtemperature ride through reduces the switching fre- quency, if the temperature of the drive rises too high.• Power loss ride through can adapt to sudden voltage drops in the supply voltage by automatically adjusting the output frequency.• The true output switching function ensures the automatic drive stops and starts when the motor disconnect switch is operated.• Auto-restart is used to automatically restart the AC drive in case of a trip.
offers the best control
Vacon AC drives are the best choice to ensure a trouble free HVAC system. Smooth starts without torque shocks minimize mechanical stress, thus the need for maintenance. The noise of the mo-tors and air-conditioning ducts is kept to a minimum and yet, maximum comfort is still attained. In addition to this, the drive includes advanced functions that increase reliability and performance of the system.
Extensive Protections -prevent failures
• Motor stall• Broken belt/Dry pump/Motor under underload • Earth fault• Over current• Over/Under voltage• Drive overtemperature• Auxiliary voltage supply
7
and all the possibilities
PID Controller - integrated functionality
• Delta P Regulation with two standard pressure transmitters. No special transmitters required.• Sleep Mode function will stop the pump when the demand is low to save energy and extend the lifetime of the pump.• Normal and Inverse Regulation of the PID controller for all control tasks.• PFC Cascade Controller with integrated auto change function for pressure booster sets and cooling compressor.• Fire Mode can be activated in case of fi re. If a fi re occurs, this function will enable the drive to maximize the time that the critical functions can operate.
Energy Saving Mode –highest effi ciency
Energy saving is one of the main reasons for choosing AC drives to be used in HVAC systems. The Energy Saving Mode (Automatic fl ux optimization) further improves the effi ciency of the motor by reducing the voltage when the full torque is not needed.
Advantage NXS NXL
Vacon NX PID x x
Sleep Mode x x
Fire Mode (Option) x x
Pump and Fan Cascade Controller 1+4 pumps 1+3 pumps
Energy Saving Mode x x
Delta P Regulation x x
8
for all environments
The product family standard EN61800-3 sets limits for both emissions and immunity from radio frequency disturbances. The environment has been divided into the 1st and 2nd envi-ronment, which, in practice, means public and industrial net-works.
Radio Frequency Interference (RFI) fi lters are typically re-quired to meet the EN61800-3 standard. These fi lters are inte-grated in the Vacon NXL (IP21 and IP54 units) and Vacon NXS as standard.
Vacon NXL (IP21 and IP54 units) and Vacon NXS fulfi l all the requirements of the 1st and 2nd environment. No additional RFI fi lters or cabinets are required.
The extremely low emission solution (Vacon class C) is avail-able for sensitive locations such as hospitals and airports.
Standards: See Technical data.
6
4 3
1
5
5
2
VACON NX EMC Hospital Airport Residential Area Commercial Light industry Area Heavy industry
C O O
H R R R R O O
L R R
T R (IT Network)
R = Required ; O = Optional
EMC Selection Table
1 2 3 4 5 6
9
proven technology for hvac
1. Hotel Golf and Wellness in Ljubljana, Slovenia
Vacon AC drives in the range of 1.1-22 kW (IP54) are controlling fans and pumps. Project delivered by Met-ronik d.o.o., Vacon partner in Slovenia.
2. Britomart Transport Center in Auckland, New Zealand
World’s fi rst underground railway station for diesel lo-comotives. Vacon AC drives up to 300 kW are control-ling the ventilation system. Project delivered by CMG Pty Ltd, Vacon partner in Australia and New Zealand.
3. Shopping Center Sello in Espoo, Finland
Vacon AC drives in the range of 1.1-30 kW are control-ling fans and pumps.
4. Royal Caribbean Cruisers
Vacon AC drives in the range of 0.75-30 kW are con-trolling HVAC systems on 6 different cruise vessels.
5. Victoria Insurance tower in Düsseldorf, Germany
Vacon AC drives in the range of 1.1–75 kW are control-ling pumps and fans.
6. Karolinska University Hospital in Stockholm, Sweden
Vacon AC drives in the range of 1.1-30 kW (IP54) are controlling fans and pumps.
7. Rondo 1 in Warsaw, Poland
Vacon AC drives in the range of 1.1–75 kW are control-ling fans. Project delivered by Telko-Poland Sp. z o.o., Vacon partner in Poland.
1
2
3
4
5
6
7
ratings & dimensions
* Type code of the IP21 unit. The type code of the IP54 unit: Replace ”2”with ”5”; for example: NXL 0003 5C5H1.Add ”AA”to the end, if two relays are required (Add ”AI”if two relays + thermistor input are required); for example: NXL 0003 5C2H1 AA.
* Type code of the IP21 unit. The type code of the IP54 unit: Replace “2” with “5”; for example: NXS 0003 5A5H1 SSS A1A2. Replace A2 with A3, if thermistor input is required.
10
Vacon NXL*
Loadability Motor shaft power
Framesize
DimensionsW*H*D (mm)
Ratedcontinuous
currentI L (A)
10%overloadcurrent
(A)
Maximumcurrent I S
400 V supply
10%overload
40°CP (kW)
NXLNXLNXLNXLNXLNXL
000300040005000700090012
5 C 2 H 15 C 2 H 15 C 2 H 15 C 2 H 15 C 2 H 15 C 2 H 1
3.34.35.67.69
12
3.64.76.28.49.9
13.2
4.46.28.6
10.81418
1.11.52.234
5.5
MF4MF4MF4MF4MF4MF4
128*292*190128*292*190128*292*190128*292*190128*292*190128*292*190
NXLNXLNXL
001600230031
5 C 2 H 15 C 2 H 15 C 2 H 1
162331
17.625.334
243246
7.51115
MF5MF5MF5
144*391*214144*391*214144*391*214
NXLNXLNXL
003800460061
5 C 2 H 15 C 2 H 15 C 2 H 1
384661
425167
627692
18.52230
MF6MF6MF6
195*519*237195*519*237195*519*237
Vacon NXS*
Loadability Motor shaft power
Framesize
DimensionsW*H*D (mm)
Ratedcontinuous
currentI L (A)
10%overloadcurrent
(A)
Maximumcurrent I S
400 V supply
10%overload
40°CP (kW)
NXS 0003 5 A 2 H 1 SSSA1A2NXS 0004 5 A 2 H 1 SSSA1A2NXS 0005 5 A 2 H 1 SSSA1A2NXS 0007 5 A 2 H 1 SSSA1A2NXS 0009 5 A 2 H 1 SSSA1A2NXS 0012 5 A 2 H 1 SSSA1A2
3.34.35.67.69
12
3.64.76.28.49.9
13.2
4.46.28.6
10.81418
1.11.52.234
5.5
FR4FR4FR4FR4FR4FR4
128*292*190128*292*190128*292*190128*292*190128*292*190128*292*190
NXS 0016 5 A 2 H 1 SSSA1A2NXS 0022 5 A 2 H 1 SSSA1A2NXS 0031 5 A 2 H 1 SSSA1A2
162331
17.625.334
243246
7.51115
FR5FR5FR5
144*391*214144*391*214144*391*214
NXS 0038 5 A 2 H 1 SSSA1A2NXS 0046 5 A 2 H 1 SSSA1A2NXS 0061 5 A 2 H 1 SSSA1A2
384661
425167
627692
18.52230
FR6FR6FR6
195*519*237195*519*237195*519*237
NXS 0072 5 A 2 H 0 SSSA1A2NXS 0087 5 A 2 H 0 SSSA1A2NXS 0105 5 A 2 H 0 SSSA1A2
7287
105
7996116
122144174
374555
FR7FR7FR7
237*591*257237*591*257237*591*257
NXS 0140 5 A 2 H 0 SSSA1A2NXS 0168 5 A 2 H 0 SSSA1A2NXS 0205 5 A 2 H 0 SSSA1A2
140170205
154187226
210280336
7590110
FR8FR8FR8
291*758*344291*758*344291*758*344
NXS 0261 5 A 2 H 0 SSFA1A2NXS 0300 5 A 2 H 0 SSFA1A2
261300
287330
349444
132160
FR9FR9
480*1150*362480*1150*362
11
technical data
Mainsconnection
Input voltage Uin 380…500 V; 208…240 V; 525…690 V; (-15%…+10%)
Input frequency 45…66 Hz
Connection to mains Once per minute or less (normal case)
Motorconnection
Output voltage 0—Uin
Continuous output current See Ratings and Dimensions
Overloadability 1.1 x IL (1 min/10 min)
Max. starting current Is for 2 s every 20 s, see Ratings and Dimensions
Output frequency 0…320 Hz; up to 7200 Hz with special software (NXS)
Frequency resolution 0.01 Hz
Controlcharacteristics
Control method Frequency control U/f; Open Loop Vector Control
Switching frequency NX_5:
1…16 kHz; Factory default 10 kHz (NXL 6 kHz)From NX_0072:1…10 kHz; Factory default 3.6 kHz
Field weakening point 8…320 Hz
Acceleration time 0…3000 sec
Deceleration time 0…3000 sec
Braking DC brake: 30 % * TN (without brake resistor), fl ux braking, brake chopper
Ambient conditions
Ambient operating temperature –10°C (no frost)…+40°C: IL
Storage temperature –40°C…+70°C
Relative humidity 0 to 95 % RH, non-condensing, non-corrosive, no dripping water
Air quality:- chemical vapours- particles
IEC 721-3-3, unit in operation, class 3C2IEC 721-3-3, unit in operation, class 3S2
Altitude 100% load capacity (no derating) up to 1000 m1% derating for each 100 m above 1000 mMax. altitudes: NXS2: 3000 m; NX_5 (380...400 V): 3000 m; NX_5 (415...500): 2000 m; NX_6: 2000 m
VibrationEN50178/EN60068-2-6
5...150 Hz: Displacement amplitude 1 mm (peak) at 5…15.8 HzMax acceleration amplitude 1 G at 15.8…150 Hz
ShockEN50178, EN60068-2-27
UPS Drop Test (according to UPS weights)Storage and shipping: max 15 G, 11 ms (in package)
Enclosure class IP21 and IP54
EMC Immunity Fulfi ls all EMC immunity requirements
Emissions EMC level C: EN 61800-3 (2004), category C1EMC level H: EN 61800-3 (2004), category C2
Safety EN 61800-5-1 (2003), CE, UL, C-UL, C-Tick; (see unit nameplate for more detailed approvals)
Controlconnections
Analogue inputs 2 pcs confi gurable: 0…+10 V, Ri = 200 kΩ, resolution 0.1%, accuracy ±1%0(4)...20 mA; Ri = 250 Ω differential resolution 0.1%, accuracy ±1%
Digital inputs NXS 6 pcs, NXL 3+1 pcs: 18…30 VDC
Auxiliary voltage +24 V, ±15%, max. 250 mA, (NXL 100 mA)
Output reference voltage +10 V, +3%, max. load 10 mA
Analogue output 0(4)…20 mA; RL max. 500 Ω, resolution 10 bit, accuracy ±2%
Digital output Open collector output, 50 mA/48 V (NXS)
Relay outputs NXS: 2 programmable change-over (NO/NC) relay outputs (OPT-A3: NO/NC+NO)NXL: 1 programmable change-over (NO/NC), add OPT-AA or OPT-AI option board in case two relays are required. Switching capacity: 24 VDC/8 A, 250 VAC/8 A,(NO/NC), 125 VDC/0.4 A. Min. switching load: 5 V/10 mA
Thermistor input (OPT-A3) Galvanically isolated, Rtrip = 4.7 kΩ
RS485 Modbus RTU as standard in Vacon NXL
Protections Overvoltage, undervoltage, earth fault, mains supervision, motor phase supervision, overcurrent, unit overtemperature, motor overload, motor stall, motor underload (dry pump, broken belt), short-circuit of +24 V and +10 V reference voltages