Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Dimensions (W x D x H)
Weight
Operating temperature
Setup time
238 x 326 x 310 [mm]
Approximately 7 kg
15 °C - 30 °C (59 °F - 86 °F)
3 min
Data memory 100 tests
Required sample volume
Cartridge information
basic test : 100 µLdilution test (v-COR): 20 µLdilution test (vf-SAA): 10 µL
Information about test parameters is embedded in the QR code attached to the cartridge.
Target species
v-T4 vc-TSH v-COR v-BA v-PRG
0.50 - 8.00 µg/dL(6.4 - 103.0 nmol/L)
0.20 - 40.00 ng/mL(0.64 - 127.20 nmol/L)
Canine Canine
P / SP / S P / S
0.25 - 5.00 ng/mL3.75 - 225.0 µg/mL
1.0 - 30.0 µg/dL (27.6 - 828.0 nmol/L)
1.0 - 50.0 µg/dL (27.6 - 1380.0 nmol/L)
(with dilution)
2.0 - 150.0 µmol/L
P / SP / S P / S
�(P / S)– �(P / S) �(P / S)�(S only) �(P / S)
–�(P / S) – –�(P / S) –
Canine
vf-SAA
Feline Canine / FelineCanine / Feline
Type of sample
26-30, NISHIAZABU 2-CHOME, MINATO-KU, TOKYO 106-8620, JAPANhttp://www.fujifilm.com/products/medical/ Ref. No. FDCAU10V R4 (19·XX·F1079·F8598) Printed in Japan ©2011 FUJIFILM Corporation
This equipment complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No. 50, dated (June 24, 2007).This equipment is a Class 1 laser product(designed according to IEC60825-1:2007 & 2014 / EN60825-1:2014)
Options
Analyzer Specifications
Reagent Cartridges Specifications
Sample barcode reader
Top Front Side
IMMUNO AU10V DRI-CHEM analyzers
FUJI PLAIN/HEPARIN TUBE andFUJI DRI-CHEM AUTO TIPS
can be used in both systems.
W 238 mm
D 326 mm
100 mm
100 mm
W 238 mm
H 310 mm
D 326 mm
H 310 mm100 mm
Dimensions
DRI-CHEM IMMUNO AU10V (Product: FUJI DRI-CHEM IMMUNO AU10V)
Measurement time
DynamicRange
Measurement Mode
Approximately 10 min
10 cartridges/box
2 °C – 8 °C (35.6 °F – 46.4 °F)
Package Unit
Reagent Strorage
System Configuration Diagram
AU10V has an automatic dilution function for v-COR measurements to accommodate serum samples with high cortisol levels. (Plasma samples are to be measured in dilution mode regardless of cortisol level.)
Automatic Dilution Function
All reagents and materials are already prepared inside the cartridge.
No need to add reagents.
Perform automatic measurements simply by inserting a tube (for samples), a tip (for sampling and injection), and a cartridge (reagents), and press the START key!
Simple 2 - step procedure
All calibrations and measurements are conducted automatically based on the QR code* attached to the bottom of the cartridge, which eliminates the need for lot calibration.
Automated calibration for reagents using attached QR code
1.5 mL or 0.5 mL sample tube can be used, allowing flexibility when collecting blood samples in accordance with the measurement situation.
Flexibility in selecting the most appropriate sample tube (1.5 mL or 0.5 mL)
TopBottom
“QR code” is a registered
trademark of DENSO WAVE INC.
Workflow
Results
10Approx.
min
Insert materials1 Press the START key2
Easy To Use
P : Plasma S: Serum *Dilution with pharmaceutical grade saline solution
NEW
Basic
Dilution*
Innovation in Immunodiagnostic Testing
Automated Fluorescence Immunoassay Analyzer
v-T4
vc-TSH
v-BA
v-COR
v-PRG
(Thyroxine (T4) )
(Thyroid-Stimulating Hormone)
(Bile Acids)
(Cortisol)
(Progesterone)
(Serum amyloid A)vf-SAA NEW
For real time diagnosis and monitoring of hormonal
and other important markers in canine and feline. To save labor operations like dispensing and mixing, AU 10V has an automatic dilution function (for vf-SAA and v-COR measurements only) .
Automatic Dilution Function
All reagents and materials are already prepared inside the cartridge.
No need to add reagents
Perform automatic measurements simply by inserting a tube (for samples), a tip (for sampling and injection), and a cartridge (reagents), and press the START key!
Simple 2 - step procedure
All calibrations and measurements are conducted automatically based on the QR code* attached to the bottom of the cartridge, which eliminates the need for lot calibration.
Automated calibration for reagents using attached QR code
1.5 mL or 0.5 mL sample tube can be used, allowing flexibility when collecting blood samples in accordance with the measurement situation.
Flexibility in selecting the most appropriate sample tube (1.5 mL or 0.5 mL)
TopBottom
“QR code” is a registered
trademark of DENSO WAVE INC.
Workflow
Results
10Approx.
min
Insert materials1 Press the START key2
Easy To Use
Serum and plasma samples are measure-
able in all tests
v-T4
vc-TSH
v-BA
Hypo/Hyperthyroidism diagnosis
Hypothyroidism diagnosis
v-COR Adisson’s Disease or Cushing’s syndrome diagnosis
v-PRG
(Thyroxine (T4) )
(Thyroid-Stimulating Hormone)
(Bile Acids)
(Cortisol)
(Progesterone)
(Serum amyloid A)
Reproduction management
Liver-related diseases diagnosis
Reagent Cartridges Specifications
vf-SAA Screening and/or monitoring of In�ammationNEW
FUJIFILM's Surface Plasmon enhanced Fluorescence technology has brought about a compact sized Fluorometry Immunodiagnostic Analyzer of high reliability and accuracy.
Ideal for in-clinic immunodiagnostic testing.
Easy to use Rapid measurement (approximately 10min)
Automated Calibration
An in-clinical Immunodiagnostic Analyzer realized by FUJIFILM’ s cutting edge technologies
Fluorescent beads
Antigen
Antibody
Thin gold film
Sample Injection Fluorescence MeasurementLaser Beam IrradiationBinding ReactionThe sample, which is mixed with the reagent, will be dispensed into the sample flow channel of the cartridge.
The analyte binds with the antibody, which will be attached to the thin gold film.
A SPR is generated upon irradiation by the laser beam.
The fluorescent intensity, which is commensurate with the level of analyte concentration, is detected.
Reagent Cup
The equipment performs fluorometry using Surface Plasmon enhanced
Fluorescence(SPF), a technology based on Surface Plasmon Resonance (SPR),
within a small cartridge.
With the SPF technology, washing for surplus fluorescent beads is not
necessary, making the measurement time shorter and the machine more
compact. Also since the fluorescence is enhanced by SPR, a low power beam is
sufficient enough to generate substantial fluorescence intensity for detection.
v-T4 Canine
y = 1.034x - 0.002r = 0.967n = 92
CLEIA (µg/dL)
AU
10 v
-T4
(µg
/dL)
v-T4 Feline
y = 0.965x + 0.024r = 0.962n = 90
CLEIA (µg/dL)
AU
10 v
-T4
(µg
/dL)
v-BA Canine
y = 0.970x - 0.600r = 0.960n = 53
Enzymatic Method (µmol/L)
AU
10V
v-B
A (µ
mo
l/L)
v-BA Feline
y = 0.933x + 0.643r = 0.967n= 62
Enzymatic Method (µmol/L)
AU
10V
v-B
A (µ
mo
l/L)
vc-TSH Canine
y = 0.941x + 0.077r = 0.983n = 72
CLEIA (ng/mL)
AU
10V
vc-
TSH
(ng
/mL)
v-COR Canine (dilution)
y = 0.999 x + 0.285r = 0.963n = 125
CLEIA (µg/dL)
AU
10V
v-C
OR
(µg
/dL)
v-PRG Canine
y = 1.051x + 0.063r = 0.957n = 102
CLEIA (ng/mL)
AU
10V
v-P
RG (n
g/m
L)
AU10V provides reliable and accurate results. It has excellent correlations with its comparison methods in serum samples.
Excellent correlation with standard laboratory analyzer
Principle of the system
Easy To UseTechnology
High Reliability
vf-SAA NEW
FUJI DRI-CHEM IMMUNO AU CARTRIDGE vf-SAA
v-PRG
FUJI DRI-CHEM IMMUNO AU CARTRIDGE v-PRG
v-T4
FUJI DRI-CHEM IMMUNO AU CARTRIDGE v-T4
vc-TSH
FUJI DRI-CHEM IMMUNO AU CARTRIDGE vc-TSH
v-COR
FUJI DRI-CHEM IMMUNO AU CARTRIDGE v-COR
v-BA
FUJI DRI-CHEM IMMUNO AU CARTRIDGE v-BA
For real time diagnosis and monitoring of hormonal
and other important markers in canine and feline.
v-T4
vc-TSH
v-BA
Hypo/Hyperthyroidism diagnosis
Hypothyroidism diagnosis
v-COR Adisson’s Disease or Cushing’s syndrome diagnosis
v-PRG
(Thyroxine (T4) )
(Thyroid-Stimulating Hormone)
(Bile Acids)
(Cortisol)
(Progesterone)
(Serum amyloid A)
Reproduction management
Liver-related diseases diagnosis
Reagent Cartridges Specifications
vf-SAA Screening and/or monitoring of In�ammationNEW
FUJIFILM's Surface Plasmon enhanced Fluorescence technology has brought about a compact sized Fluorometry Immunodiagnostic Analyzer of high reliability and accuracy.
Ideal for in-clinic immunodiagnostic testing.
Latex agglutination (µmol/L)
vf-SAA Feline
AU
-10V
vf-
SAA
(µm
ol/
L)
y = 0.979x + 1.417r = 0.969n = 60
Serum and plasma samples are measure-
able in all testsEasy to use Rapid measurement
(approximately 10min)Automated Calibration