UVAX CONCEPTS USA INC – 1434 Spruce Street , Suite 100 – Boulder 80302 Colorado
1
UVAX CONCEPTS USA INC PLC CONTROL SYSTEMS
UVAX CONCEPTS USA proposes complete technical solutions (hardware and software) for the lighting infrastructures to turn facilities into “controllable assets” more reliable,
efficient, secure and sustainable While the energy reduction attained by LEDs does reduce the amount of energy available to be saved through lighting controls, these systems remain an economical strategy for achieving added efficiency. Lighting controls also bring a host of non-‐energy benefits, such as improved monitoring and maintenance, enhanced occupant experience, space utilization visualizations, and more. Building energy codes largely drive the adoption of more basic lighting controls such as sensors. Yet, those codes also create the opportunity for a lighting project to upgrade to a more comprehensive control system for a modest price increase.
Contact: Roberto del Navío – [email protected] -‐
1434 Spruce Street. Suite 100. Boulder. 80302 -‐ Colorado US -‐ www.uvaxtech.com
UVAX CONCEPTS USA INC – 1434 Spruce Street , Suite 100 – Boulder 80302 Colorado
2
PLC CONTROL SOLUTIONS - HARDWARE AND SOFTWARE (CONTROL MANAGEMENT SYSTEM)
A complete intelligent solution UVAX CONCEPTS Control Systems
UVAX CONCEPTS USA integrated complete solutions allow the optimization of current and future needs The results is a more efficient system, makes preventive maintenance possible, reduces total system cost and anticipate future infrastructure needs. Power Line Communication Technology (B-‐PLC). Flexible & Scalable solutions
UVAX CONCEPTS USA INC is a US company located in Boulder (Colorado) that provides solutions, hardware and software, that encompass physical devices (LEDs, sensors, intelligent electronic devices, cameras, alarms, information panels, wifi points) that may share real-‐time or near real-‐time data with the operations center and allow the remote control facilitating the maintenance and condition monitoring of the infrastructures and facilities turning them into “controllable assets” more reliable, efficient, secure and sustainable by providing “Intelligent Control”. • Innovative non-‐energy benefits built in to lighting control systems are being cited more and more often as the key decision
factor for installing a networked lighting control system. • While all lighting control systems still function at their core to dim or shut off lights that are not needed, these systems are
also providing other features that are potentially even more valuable to building owners and managers. The UVAX controls are specially designed for facilities that require a flexible and active management. These controls allow: -‐ To capture the information which can be programmed according to the management needs and coming from different
devices as sensors, cameras, etc, based on schedules, presence, consume, or any other specific needs. -‐ The transmission of this information and the interaction with a Control Center (though the webserver) allowing the facility
managers to take the necessary decisions to optimize the resources and the operations -‐ The real time remote monitoring from any device (lap top, phone,..) of the installation/facility from the Control Center. The UVAX system has two main elements; the NODE, installed at the device that needs to be controlled, and the Concentrator installed at the control panel or switch board where the circuit breakers are. The Concentrator is also responsible for linking (GATEWAY) the different devices with the internet server, where the management software resides. It is, therefore, a CLOUD base solution, where the user can configure, supervise and remotely control the whole system anywhere from the internet
UVAX Control Solutions differentiates by providing a bandwidth up to 200 times faster, allowing additional and advanced features to be integrated into the same communication channel, making it a cost effective scalable Plug & Play system. This integration can be done in existing or new facilities and brings the opportunity to anticipate future high speed data needs based on facility management demands without any remodeling or new wiring just by connecting these new devices to the existing Control System already in place. Outdoor Lighting
-‐ Roads/Highways -‐ Parks -‐ Tunnels -‐ Sports centers -‐ Outdoor Parking -‐ Universities…
Indoor Commercial /industrial facilities
-‐Hangars/Airports -‐ Shopping malls -‐ Warehouses -‐ Stations -‐ Gymnasiums -‐ Greenhouses Other Big facilities
BROAD BAND POWER LINE COMMUNICATION (B-‐PLC): UVAX CONCEPTS KEY BENEFITS
UVAX B-‐PLC (data transmission through the power line) can achieve data transmission speeds of up to 600 MB/s. Based on this licensed technology, UVAX has developed solutions that are perfectly flexible and can integrate Wifi, ZigBee or Bluetooth modules if decided by the specific project conditions or client requirements. Perfect solution for existing or new facilities and communication infrastructures installed. UVAX (B-‐PLC), a big difference for the (IIOT): • Real Time Performance • High speed and Secure Transmission • Outperforming Modulation Technology • Plug and Play Installation and Configuration • Standard Base IP Communication • Scalability to add Nodes -‐new Applications • Self-‐Healing Network • Low Cost.
• Flexible and scalable solutions • Increase and anticipate operational effectiveness and
productivity. • 24/7 access to data and continuously monitor and
control different sections • Boost operational performance and improve
process efficiencies without adding head count. • Reduce the life cycle costs in project development,
operations, and maintenance • Improve safety, environmental, regulatory compliance • Support increasingly remote logistics • Highly configurable and scalable to meet all
business requirements • Easy to learn and install. CMS (Control Management
System) is very intuitive and user-‐friendly interface • Multi-‐user and multi-‐equipment capability • Allow system’s update, anticipates new demands
UVAX CONCEPTS USA INC – 1434 Spruce Street , Suite 100 – Boulder 80302 Colorado
3
CONCENTRATORS HEAD END -‐ 9009 BROAD BAND-‐ POWER LINE COMMUNICATION SPECIFICATIONS
APPLICATIONS INSTALLATIONS, CAUTIONS AND WARNINGS
(B-‐PLC) CONCENTRATORS -‐ HEAD END 9009 The Head End is installed in the electrical panel containing the circuits for the
fixtures to be controlled. The Head End is responsible for managing each of the fixtures, sensors and devices. It saves the configuration and time schedule of all fixtures, manages the network, and verifies the proper working. Broadband Power Line Communication • Real Time Performance • Secure Transmission • Outperforming Modulation Technology (OFDM) • PnP Installation and Configuration (Plug and Play) • Standard Base IP Communication • Scalability to add Nodes and new Applications • Self-‐Healing Network • High Speed Transmission (up to 600 MBs) • Cost effective
Integrating • Optimal path selection protocol: a technology that finds the best route in terms of attenuation and number of hops to connect a Node to the Head End.
• Adaptive load balancing: a technology that optimizes cannel allocation to maximize the throughput in a network with many Nodes.
• Remote firmware upgrade: capable of installing a new Node or application software from a centralized control center.
Name Head End CA 9009 Product Code LLP-‐PLC-‐Head-‐End-‐CA-‐9009 Metering Linux PLC+RJ45+3G+Power Metering Input Voltage 100 -‐ 277VAC Frequency 50 ~ 60 Hz Power Factor > 0.80 Maximum Power 15W Max output voltage 4.5 VRMS Max output current 70mA Operating Temp -‐40˚C -‐ +60˚C Dimensions and weight
12 inches H X 4 inches X 1 inch . (Weight 2,45lb)
IP IP65 Indoor and Outdoor lighting, safety and security cameras control, and sensors connectivity all of them in different segments as warehouses, parkings, hangars, indoor farming or sport facilities among others. • This device doesn’t have replaceable or interchangeable elements, so it mustn’t be manipulated. • If the device is installed or used in a manner not specified by the accompanying documents, the safety of the device may be impaired. • Do not install around combustible gas or gas vapor. • Do not install in an electrical service with current or voltage outside of the specified limit of the device • Do not operate this device with the cover removed. • Beware of working around this device when the voltage is live. There is a risk of electric shock • See instructions for connection diagrams
UVAX family of “Industrial Internet of Things” Gateways are resourceful multifunction controllers, equipped to interface with different and fully instrumented networks, perform required protocol conversions, and enable remote access to exploit the full potential of industrial internet
UVAX IIoT Gateways, allow collection and analysis of an enormous amount of data coming from sensors and other advanced instrumentation networks, which can be used to improve facility performance, and inevitably the efficiency of the systems and networks that link them. Even the data itself can become intelligent instantly knowing which users it needs to reach. The Linux Operating System in conjunction with a large set of libraries and software modules provide an easy to use system design platform, making application development a straight forward task. The higher end models integrate high performance processors, with enough memory and computing power to run complex applications and handle challenging data analytics and work with larger volumes of real-‐time data. Implementing system security with standard 128-‐, 192, or 256 Bit AES encryption is as easy as adding the required module to the operating system. These Gateways are, therefore, Enablers and Catalysts within the Industrial Internet of Things.
UVAX CONCEPTS USA INC – 1434 Spruce Street , Suite 100 – Boulder 80302 Colorado
4
NODES NX 80 SERIES BROAD BAND-‐ POWER LINE COMMUNICATION SPECIFICATIONS
INSTALLATIONS, CAUTIONS AND WARNINGS • See instructions for
connection diagrams and installation
(B-‐PLC) NODES – NX 80 SERIES NODES (NX 81-‐NX82-‐NX83-‐NX84) The Receiving Node is integrated within the LED fixture/device to link it and communicate with the Head End Node, the main functions are: • Data transfer between the fixture/device and Head End (concentrator)
• Set the LED fixture level (dimming, on/off) as requested in real time by the system settings
• Interface with occupancy, light or other type of sensors
• Check proper operation of the unit • Supervise operating temperature
Broadband Power Line Communication • Real Time Performance • Secure Transmission • Outperforming Modulation Technology (OFDM) • PnP Installation and Configuration (Plug and Play) • Standard Base IP Communication • Scalability to add Nodes and new Applications • Self-‐Healing Network • High Speed Transmission (up to 600 MBs) • Cost effective Name PLC NODE SERIES NX 80 Product Code NX81-‐NX82-‐NX83-‐NX84 INPUT Input Voltage range 100 ~ 277VAC Input Frequency 50 ~ 60 Hz Power Factor > 0.80 Maximum output Power 4W Vac Output Power Line Single-‐Phase ONLY Output voltage range 100 ~ 240 VAC Max output current 4A 0.. 10 V Output Control Output voltage range 0 (min) ~ 10V (max) Maximum output current 50mA I2C Interface High level output voltage 2.4V (min)/3.3V(typ) Low level output voltage 0V (Typ) / 0.4 V (max) Input voltage 3.3 V (typ)/ 3.6 V (max) PLC Bandwidth Initial Frequency 2MHz Final frequency 12 MHz Bandwidth 10MHz Operating Temp -‐25ºC ~ 55ºC Storage Temp range -‐25ºC ~ 85ºC Maximum Temp (case) 55ºC Dimensions and weight 3inX7,2inX1,32in.(1,1lb) IP IP65
If the device is installed or used in a manner not specified by the accompanying documents, the safety of the device may be impaired.
NX80 Series The NX80 series is a PLC node with additional interfaces and functionalities. The series consists of four devices with common features and some individuals. Every NX80 node includes:
• 0..10 Vdc output for dimming control of lamps. • I2C interface for external connectivity. • Real Time Clock (RTC) which ensures the
maintenance of the date and time after an off state.
• PLC connectivity. Optional features are:
• Measurement of the power consumption of the luminaire and power fault detection.
• Ethernet 10/100 Mbps Full-‐Duplex port and auto MDI/MDIX with RJ45 connector for IP connectivity to devices such as computers, cameras, sensors, audio systems …
Integrating • Optimal path selection protocol: a technology that finds the best route in terms of attenuation and number of hops to connect a Node to the Head End.
• Adaptive load balancing: a technology that optimizes cannel allocation to maximize the throughput in a network with many Nodes.
• Remote firmware upgrade: capable of installing a new Node or application software from a centralized control center