Utilities 2.0: Addressing Regulatory Updates from FDNY, PSC & NYISO
1
August 7TH, 2014 10:00am –11:30am
Panelists:
Gary Davidson, New York Independent System Operator, Team Leader, Strategic and
Business Planning Group
Vani Dantam, Axion Power International, Senior Vice President, Business Development,
Sales & Marketing
Diana Sweeney, EnergyWatch Inc., COO
Norman Mah, Consolidated Edison Solutions, Manager of Regulatory Affairs
Moderator:
Scott Thigpen, Booz Allen Hamilton, Senior Associate @AGRION
Agrion.org
energy economics simplified
Diana Sweeney EnergyWatch Inc., COO
Experience:
Present: EnergyWatch Inc. – COO & Co-founder, NYECC - Executive Director
Past: Insignia/ESG – Director - Energy Services, Property Management Account Executive, Contract Negotiator
2
Affiliations:
Association Real Estate Women (AREW)
Vistage International
New York Energy Consumers Council (NYECC), Past Co-President & Board Member
Education:
NYU – M.A., Real Estate Investment
St. John’s University – B.A., English Literature
energy economics simplified
Solutions & Services watchwire
Web-Based Utility Data Management & Reporting Regulatory Compliance Reporting Sustainability Reporting
Utility Budgets
Consumption Forecast Public Service Commission rate cases (delivery rates) Forward market supply projections (supply rates)
3
Energy Procurement Electricity Natural Gas Renewable Energy Certificates & VERs
Custom Monthly Reporting
Budget Variance Reports Electric Rent Inclusion Submeter Revenue Reports
energy economics simplified
Who Do We Work For?
4
FDNY CODE UPDATE
5
Summary of Code Compliance
Energy Storage Project
Within scope of FC 608.1? -Technology Type -Applications
Follow Safety and Certificate of Fitness Requirements in FC
Application for Modification (Variance)
Yes
No
FC 608.1 - Scope
6
608.1 Scope. Stationary storage battery systems having an electrolyte capacity of more than 50 gallons (189 L) for flooded lead acid, nickel cadmium (Ni-Cd) and valve-regulated lead acid (VRLA), or 1,000 pounds (454 kg) for lithium-ion and lithium metal polymer, used for facility standby power, emergency power or uninterrupted power supplies, shall comply with this section and FC Table 608.1.
7
FC 601.4.3 Supervision of Battery Systems. Battery systems subject to compliance with the requirements of FC 608 shall be under the general supervision of a person holding a certificate of fitness.
Safety & Supervision Requirements
8
Application for Modification (Variance)
CTS Upgrades to NYISO and PJM
August 7, 2014
Norman Mah
Consolidated Edison Solutions
9
New York Transmission System
800/2,000
1,300/1,500
250/330
(500)/1,800
1,050/2,600
100/2,500
Avg 2013 Usage/Approx Line Rating
10
The Coordinated Transaction Scheduling Project
Difficult to economically schedule energy transactions between ISO’s
50% of the real-time Transactions are uneconomic
For 2 years, NYISO and PJM worked on CTS improvements
Deployment is scheduled for 4th Q of 2014
Will significantly improve the economic scheduling of energy between PJM and NYISO
Change is expected to provide Millions in consumer savings for energy
11
CTS Improvements
Improves the tools participants use to schedule transactions between PJM and NY
Reduces requirement to submit a transaction 1 ¼ hour time ahead of the schedule to only ¼ hour
Eliminates the need for participants to forecast the economic flow order and purchase energy from one ISO before scheduling into the other.
CTS schedules based on a price margin between PJM and NYISO
Schedules are for 15 minutes of flow instead of the full hour
Should increase usage, price convergence, and reduce production / consumer costs
12