Click here to load reader

User´s AXFA14G/C Manual Magnetic Flowmeter Remote ... · PDF file AXFA14G/C Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] AXF Magnetic Flowmeter Integral

  • View
    4

  • Download
    0

Embed Size (px)

Text of User´s AXFA14G/C Manual Magnetic Flowmeter Remote ... · PDF file AXFA14G/C Magnetic...

  • User´s Manual

    AXFA14G/C Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] AXF Magnetic Flowmeter Integral Flowmeter [Software Edition]

    IM 01R20C02-01E-E 3rd Edition, Nov. 2006

    IM 01R20C02-01E-E

  • i

    CONTENTS

    IM 01R21C02-01E-E 3rd edition, Nov. 2006All Rights Reserved, Copyright  2003, Yokogawa ElectricCorporation

    Contents 1. INTRODUCTION ..................................................................................1-1

    1.1 Using the Magnetic Flowmeter Safely .............................................................1-2 1.2 Warranty .............................................................................................................1-3 1.3 Combination Remote Flowtubes .....................................................................1-3 1.4 ATEX Documentation ........................................................................................1-4

    2. HANDLING PRECAUTIONS ................................................................2-1 2.1 Checking Model and Specifications ................................................................2-1 2.2 Accessories .......................................................................................................2-1 2.3 Storage Precautions .........................................................................................2-1 2.4 Installation Location Precautions ....................................................................2-2

    3. INSTALLATION....................................................................................3-1 3.1 Installation Location ..........................................................................................3-1 3.2 Mounting ............................................................................................................3-1

    4. WIRING .................................................................................................4-1 4.1 Wiring Precautions ............................................................................................4-1 4.2 Cables ................................................................................................................4-1 4.3 Wiring Ports .......................................................................................................4-3 4.4 Wiring Connections .........................................................................................4-4

    4.4.1 Removing Cover.................................................................................................... 4-4 4.4.2 Terminal Configuration ......................................................................................... 4-4 4.4.3 Precautions for Wiring of Power Supply Cables ................................................ 4-4 4.4.4 DC Power Connection .......................................................................................... 4-5 4.4.5 Grounding .............................................................................................................. 4-5 4.4.6 Wiring the Remote Flowtube with AXFA14 Converter ....................................... 4-6 4.4.7 Connecting to External Instruments ................................................................... 4-7 4.4.8 Installing the Cover ............................................................................................... 4-8

    5. BASIC OPERATING PROCEDURES..................................................5-1 5.1 Operating Panel Configuration and Functions ...............................................5-1 5.2 Display Unit Setting Methods ...........................................................................5-2

    5.2.1 Display Mode →→→→→ Setting Mode ............................................................................ 5-2 5.2.2 Setting Mode .......................................................................................................... 5-4

    5.3 Parameter Setting Procedure ...........................................................................5-4 5.3.1 Setting Example for Selection-Type Data: Flow rate units ............................... 5-4 5.3.2 Setting Example for Numeric-Type Data: Flow-rate span ................................. 5-6 5.3.3 Setting Example for Alphanumeric-Type Data: Tag number ............................. 5-7

  • iiIM 01R21C02-01E-E 3rd edition, Nov. 2006

    CONTENTS

    6. PARAMETER DESCRIPTION .............................................................6-1 6.1 Parameters .........................................................................................................6-1 6.2 Parameter Lists .................................................................................................6-1 6.3 Parameter List Overview ...................................................................................6-2 6.4 Parameter Description ....................................................................................6-12

    (1) Menu B: Easy Setup items ..................................................................................... 6-12 (2) Menu C: Basic Setting items.................................................................................. 6-15 (3) Menu D: Total Setting items................................................................................... 6-17 (4) Menu E: Pulse Setting items.................................................................................. 6-18 (5) Menu F: Status Functions Setting items ............................................................. 6-19 6) Menu G: Alarm Setting items ................................................................................... 6-25 (7) Menu H: Display Setting items............................................................................... 6-29 (8) Menu J: Auxiliary Function Setting items ............................................................. 6-29 (9) Menu K: Diagnostic Function Setting items ........................................................ 6-32 (10) Menu M: Automatic Zero Adjustment Function Setting items ........................... 6-32 (11) Menu N: Loop Test (Output Test) Setting items ................................................ 6-33 (12) Menu P: Parameter Protection password items ................................................ 6-33

    6.5 Alarm Functions ..............................................................................................6-34 6.5.1 Alarm Levels ......................................................................................................... 6-34 6.5.2 Alarm Selection .................................................................................................... 6-35 6.5.3 Alarms & Warning Messages ............................................................................. 6-37

    6.6 Precautions for the AXF Integral Flowmeter .................................................6-39

    7. OPERATION VIA BRAIN TERMINAL (BT200) ...................................7-1 7.1 BT200 Basic Operations ...................................................................................7-1

    7.1.1 Key Layout and Display ......................................................................................... 7-1 7.1.2 Key Descriptions ................................................................................................... 7-1

    7.2 AXFA14 Operation Using a BT200 ...................................................................7-3 7.2.1 BT200 Connection ................................................................................................. 7-3 7.2.2 The data update and upload/download function of BT200 ............................... 7-3 7.2.3 BT200 Panels & Flow Data Display ...................................................................... 7-4

    7.3 Parameter Setting Using a BT200 ....................................................................7-4 7.3.1 BT200 Setting of Selection-Type Data: Flow-rate units .................................... 7-4 7.3.2 BT200 Setting of Numeric-Type Data: Flow-rate span....................................... 7-5 7.3.3 BT200 Setting of Alphanumeric-Type Data: Tag number ................................... 7-6

  • iii

    CONTENTS

    IM 01R21C02-01E-E 3rd edition, Nov. 2006

    8. OPERATION VIA HART COMMUNICATOR .......................................8-1 8.1 Conditions of Communication Line .................................................................8-2

    8.1.1 Interconnection between AXFA14 and HART Communicator ........................... 8-2 8.1.2 Communication Line Requirements .................................................................... 8-2

    8.2 Basic Operation of the HART Communicator (Model 275) .............................8-3 8.2.1 Keys and Functions ............................................................................................... 8-3 8.2.2 Display .................................................................................................................... 8-4 8.2.3 Calling Up Menu Addresses ................................................................................. 8-4 8.2.4 Entering, Setting and Sending Data .................................................................... 8-5

    8.3 Parameters .........................................................................................................8-5 8.3.1 Parameter Configuration ...................................................................................... 8-5 8.3.2 Data Renewing ....................................................................................................... 8-5 8.3.3 Checking for Problems ......................................................................................... 8-6 8.3.4