    HXE34 three phase keypad meter

    2

    Index

    1 Introduction ............................................................................. ............................................................ 3

    1.1 summary .................................................................. ............................................................... ........ 3

    1.2 Technical Parameter ............................................................. ........................................................... 4

    1.2.1 Basic Parameter .............................................................. ........................................................... 4

    1.2.2 Electrical Parameters ...................................................... ........................................................... 5

    1.2.3 Environment ........................................................ .............................................................. ........ 5

    1.2.4 Standards ............................................................. ................................................................. ..... 5

    2 HXE34 Prepayment Keypad Meter ................................................................................................... 6

    2.1 Overall figure ............................................................ ................................................................. ..... 6

    2.2 Dimension....................................................................................................................................... 6

    2.3 Installation ..................................................................................... ................................................. 7

    2.3.1 Installation method ................................. ............................................................... .................. 8

    2.3.2 Connection ......................................................... ................................................................. ..... 8

    3 LCD display ............................................. ................................................................. ........................... 8

    3.1 LCD Introduction ............................... ................................................................. ........................... 9

    3.2 Display Mode ..................................... ................................................................. ......................... 10

    3.3 LED Indicator ........................................................... ................................................................. ... 11

    3.4 Different LCD images .............................................. .............................................................. ...... 11

    4 Keypad ...................................................... ................................................................. ......................... 11

    5 Meter Function ................................................... ................................................................. .............. 12

    5.1 Energy measurement ................................................ .............................................................. ...... 12

    5.2 Communication .................................................................. .......................................................... 12

    5.3 STS function ............................................................. ................................................................. ... 12

    5.3.2 Credit the meter .......................................................................................... ......................... 13

    5.4 Billing ....................................................................................................... .................................... 18

    5.5 Low Credit Alarm ................................................................ ......................................................... 18

    5.6 Inquiry Button .............................................................................................................................. 19

    5.7 Relay Control ............................................................ ................................................................. ... 22

    5.8 Over Loading Management .......................................................................................................... 23

    5.9 Event Record ...................................................................... .......................................................... 23

    5.10 Event indicators ................................................................ .......................................................... 24

    5.11 Up-limit Credit........................................................ .............................................................. ...... 24

    5.12 Back-up Battery ................................................................ .......................................................... 25

    5.13 Fixed Expense ............................................................................................................................ 25

    6 Meter storage ................................................................ ................................................................ ..... 25

  • 8/10/2019 User ManualHXE34 Indonesia

    3/26

    HXE34 three phase keypad meter

    3

    1 Introduction

    1.1 summary

    Hexing Prepayment System is a new billing methodology. It combines a superior

    keypad metering equipment and an advanced one-way communication

    management system. Similar to a credit purchase for a pay-as-you-go mobile

    phone, data transfer from POS (point of sale) is made via a numeric token using

    STS (Standard Transfer Specification) encryption techniques and protocol. User

    only needs to key in the code printed on the token thru keypad to credit the meter.

    This user manual covers general information about HXE34 integrated keypad

    meter, which is used in advanced Hexing Prepayment System.

    Equipped with proven keypad technology, HXE34 contains all critical metering,

    token decryption, relay disconnection and reverse energy detection functionality.

    Together with the modern look and feel, it can be used in a wide range of

    application for all consumer types.

    1.1.1 Advantages

    Hexing Prepayment System offers significant benefits and convenience both to

    the utility and the end user.

    For the Consumers

    a) Efficient management:

    In the manner of pay-as-you-go, user can purchase token from any

    authorized vending station.

    Helps the individual to monitor their spending on electricity

    Emergency credit and friendly credit is allowed

    Refund is allowed.

    b) User friendly operation

  • 8/10/2019 User ManualHXE34 Indonesia

    4/26

    HXE34 three phase keypad meter

    4

    Various methods are available to pay for the credit.

    Access to meter data by keying in short code

    When the user key in enquiry code information, the LCD will display

    the enquiry information.

    c) Safety

    Each token can specifically be used to credit a particular meter with a

    certain serial number only.

    Token can be re-issued if it is lost for some reason.

    For the Utility

    a) Significant savings in cost :

    Lower administration and billing costs

    Reduction in bad debts

    Working capital savings through earlier receipt of payments

    b) Efficient management:

    Usage can be monitored, predicted, etc, therefore making future

    planning easier

    EndUser habit analysis

    c) Safety:

    Using STS encryption technology and protocol which assure high

    security.

    The credit could be limited in order to eliminate the risk of theft.

    Whole close meter construction to avoid meter damage from outside

    1.2 Technical Parameter

    1.2.1 Basic Parameter

    Rated voltage3230/400V

    Rated current: 20(100)AFrequency50Hz

  • 8/10/2019 User ManualHXE34 Indonesia

    5/26

    HXE34 three phase keypad meter

    5

    Pulse constant1000imp/kWh

    Class1.0

    Undertension mode: transformer undertension

    Current sensors3CT

    DisplayLCD

    1.2.2 Electrical Parameters

    Voltage variation range0.8Un1.2Un

    Voltage Circuitry Wastage2W

    Current Circuitry Wastage2VA

    Impulse withstand voltage: 4kV

    Insulation: 4kV 50Hz 1min

    Electrostatic discharging test: 8kV

    Withstand surge: 8kV

    1.2.3 Environment

    Operation Temperature25+55

    Relative Humidity85

    1.2.4 Standards

    IEC62053-21: Electricity metering equipment (a.c.)Particular requirements

    Part 21: Static meters for active energy (classes 1 and 2).

    IEC62052-11:Electricity metering equipment (AC) General requirements,

    tests and test conditions

    Part 11:Metering equipment.

    IEC62055-41: Electricity MeteringPayment Systems

    Part 41: Standard Transfer; Specification Application layer protocol for

    oneway token carrier systems.

    IEC62055-51: Electricity MeteringPayment Systems

  • 8/10/2019 User ManualHXE34 Indonesia

    6/26

    HXE34 three phase keypad meter

    6

    Part 51: Standard Transfer Specification Physical Layer Protocol for

    one-way numeric and magnetic card token carriers.

    2 HXE34 Prepayment Keypad Meter

    2.1 Overall figure

    ()

    2.2 Dimension

  • 8/10/2019 User ManualHXE34 Indonesia

    7/26

    HXE34 three phase keypad meter

    7

    2.3 Installation

    The meter should be installed where is dry and ventilative. It is better to be

  • 8/10/2019 User ManualHXE34 Indonesia

    8/26

    HXE34 three phase keypad meter

    8

    installed in the meter box.

    2.3.1 Installation method

    For securely mounting the meter, to the meter board, the meter base is provided

    with2 screws mounting holes, 1 slotted meter support bracket at the top that can

    be fixed by using a M410 screw, and 2 round hole on each side in the bottom

    half of the base. The two round hole should be fixed by using PA410 or PA412

    screw.

    The meter board should be fixed firmly.

    2.3.2 Connection

    Meter should be connected in the right way according to the wiring diagram

    below:

    NOTE:Use copper cable as the lead-in wire to terminal block, and the screws in

    the terminal block should be screwed down tightly to avoid burnt because of bad

    contact or thin lead-in wire.

    3 LCD display

    Easy-to-read backlit LCD is used. Below is the image of LCD with all segments

    display.

  • 8/10/2019 User ManualHXE34 Indonesia

    9/26

    HXE34 three phase keypad meter

    9

    3.1 LCD Introduction

    LCD Display

    Segments

    Description

    In 62format (6-digit integral plus

    2-digit decimal), it can display all kinds of

    information for the convenience of customer

    (such as EC, current time and credit)

    Communication indication

    Low battery indication

    Phase A indication

    Energy indication

    Energy reverse indication

    Relay-on indication

    Relay-off indication

  • 8/10/2019 User ManualHXE34 Indonesia

    10/26

    HXE34 three phase keypad meter

    10

    Unit

    (S1S8) Status indication

    OBIS code

    Time indication

    OBIS code

    Date indication

    Credit indication

    3.2 Display Mode

    There are three display modes: scroll display, static display and enquiry display.

    The scroll display table is configured.

    1) Scroll Display

    It is available when the meter is connected. The scroll display list is Credit, total

    energy, rated power, SGC, tariff index, tariff kWh, phase A power, phase B power,

    phase C power.

    Scroll Display is the default display mode

    2) Static Display

    When meter is disconnected from main line, static display is available to indicate

    the balance.

    3) Enquiry display

    When the user keys in enquiry code information, the LCD will display the

    enquiry information.

    Note: If meter is re-connected, scroll display will start automatically.

  • 8/10/2019 User ManualHXE34 Indonesia

    11/26

    HXE34 three phase keypad meter

    11

    3.3 LED Indicator

    In addition to the displays required above the meter must display the following

    information:

    There are three LED indicators:

    Alarm LED:

    If special event occurs on the meter, the LED will light on and go out till the

    event restored. The event is configurable.

    Balance credit indicator:

    Indicate the storage credit. Three level of storage credit can be indicated by

    different color. The three levels are programmable.

    Pulse indicator LED

    The red LED on the right keeps flashing when meter is connected, indicating the

    user is consuming energy.

    3.4 Different LCD images

    Date, time, balance credit, total energy, rated power, SGC, instantaneous power

    and tariff index is displayed on the LCD.

    4 Keypad

    User interaction with the meter (such as credit the meter) and access to meter

    information (such as energy consumption) is available by using the keypad.

  • 8/10/2019 User ManualHXE34 Indonesia

    12/26

    HXE34 three phase keypad meter

    12

    There are all together 12 keys, which are made up of 10 numeric figure keys from

    0 to 9, backspace key ( ) and enter key ( ).

    When pressed the keypad has tactile feedback.

    Note: In case of power off, meter enter low power mode, user need to press the

    1st code up to 1 second and input the other code normally.

    5 Meter Function

    5.1 Energy measurement

    HXE34 Keypad meter can measure energy in security mode, which means it

    records reverse energy as forward one, and adds this value to total energy

    consumption. The registration range is 000000.00 ~ 999999.99 kWh.

    |A| = |-A| + |+A|

    The meter can also measure instantaneous power, voltage and current.

    5.2 Communication

    HXE34 keypad meter has optical port on the top right corner; the optical port is

    designed in accordance with IEC62056-21.Meter parameters are programmable

    through Hexing PC software.

    5.3 STS function

    5.3.1 Purchase a token

    Similar to a pay-as-you-go mobile phone, credit can be purchased from any

    authorized vending station.

    The user will supply the vendor with meter serial No. and the amount that he/she

    wishes to purchase. If meter serial No. is not available, it is still possible to

    purchase electricity supplying with other registered information such as physical

  • 8/10/2019 User ManualHXE34 Indonesia

    13/26

    HXE34 three phase keypad meter

    13

    address of the user.

    The vendor will in return hand the user with a token with a 20-digit credit code,

    which is generated using STS encryption techniques and protocol. All data such

    as monetary amount, meter key. and date of transaction reside in this code. In this

    way, all tokens are meter serial number specific, which means that a token can

    only be used on one specific meter.

    If user buys token from a vendor and would for some reason lose it, no one would

    be able to use the token (on a different meter) unless it is entered into the initial

    buyers meter. This makes a very safe and controlled environment.

    5.3.2 Credit the meter

    The procedure of the credit meter is as below:

    1. User get credit TOKEN, such as 64188786299167809510 after

    purchase credit at CDU or POS. This TOKEN is encrypted by credit value,

    data and key.

    2.Please key in 20-digit code that appears on the token through keypad on the

    meter.

    The code will be scroll display on the LCD from right to left. Every 4 digits will

    be separated by -.

    During the process of topping up stored value, the time interval allowed for

    keying between the 2 digits should not be more than 10 seconds. Otherwise the

    digits, which have already been keyed, will be deleted automatically.

    The following three LCD images display the process of entering credit code

    6418-8786-4188-8780-9510.

  • 8/10/2019 User ManualHXE34 Indonesia

    14/26

    HXE34 three phase keypad meter

    14

    1)

    Verify entered code on LCD.

    2) Press Backspace to delete incorrectly entered digit.

    3) Press Enter to confirm when the code is entered completely and correctly.

    5.3.3 The acceptance or rejection of a token

    Acceptance

    LCD can display the credit amount immediately and there is SS shown on the

    top left corner of LCD.

    The 20-digit code is entered correctlythe credit amount is300.00kWh

    Rejection

    EE will be shown on the top left corner of LCD.

    Any one of below problems will cause token rejection:

  • 8/10/2019 User ManualHXE34 Indonesia

    15/26

    HXE34 three phase keypad meter

    15

    a)The 20-digit TOKENis not entered correctly.

    b)The TOKEN has been used to credit meter before.

    c)The token is beyond the validity.

    d)The key is beyond validity

  • 8/10/2019 User ManualHXE34 Indonesia

    16/26

    HXE34 three phase keypad meter

    16

    5.3.4 Management

    Meter can be managed through key in short code

    1. Common management code:

    Common management code is used to test meter performance and inquire meter

    parameters. Such common code is not encrypted by STS and can be used in any

    prepayment meter that in accordance with STS.

    a) The meter performance test include two parts:

    Relay test

    Note: The relay test will operate the reverse current status. If the remain credit is

    below 0, the relay is not permitted to connect. After 2 minutes, the relay will

    return to the initial status.

    LCD test

    b) The Display item as follow:

    Credit available

    Display key version number

    Tariff index

    Maximum power

    Meter status

    Total power consumption

    Meter version

  • 8/10/2019 User ManualHXE34 Indonesia

    17/26

    HXE34 three phase keypad meter

    17

    2. Special management code:

    Special management code is encrypted by CTS, which includes time and relevant

    management information. Such code can only operate the meter that has identicalkey.

    The main function as follow:

    Maximum power setting

    Remaining credit clear

    Key Modification

    Event status clear

    3. Relay test

    If the relay is connected, try to disconnect it; if the relay is open, try to connect

    the relay.

    NOTE: If the current credit

  • 8/10/2019 User ManualHXE34 Indonesia

    18/26

    HXE34 three phase keypad meter

    18

    Key in the second token, Successful Modification of the Key:

    5.4 Billing

    The meter has freeze function, it will day-freeze automatically at zero hour

    everyday; month-freeze automatically at first days zero hour of every month. The

    month-freeze information includes the energy, credit and expenditure of current 5

    months. User can query the freeze information by functional key

    5.5 Low Credit Alarm

    Visible and audible low credit alarm is available to facilitate user to manage the

    balance and credit the meter in time. This feature is programmable through PC

    software.

    a) Visible low credit alarm

    There are three thresholds which is programmable in the meter.

  • 8/10/2019 User ManualHXE34 Indonesia

    19/26

    HXE34 three phase keypad meter

    19

    Green LED on - When credit is full or have enough credit

    Red LED on- When remaining credit is less than second alarm

    thresholds

    b) Red LED flashes- When the remaining credit is less than third alarm

    thresholds

    c) Audible low credit alarm

    When credit stored is less than first alarm thresholds, the buzzer will alarm. User

    can cancel the audible alarm by key in short code 812.

    NOTE: The buzzer cannot alarm during 20:00 ~~08:00 when users are in rest.

    5.6 Inquiry Button

    A list of short codes is defined to meet various needs of user. User only need to

    key in particular 3-digit short code through keyboard to interact with meter and

    access to data.

    Short Code Function Short Code Function

    800 Total Energy Consumption 801 Balance Energy

    802 Current date 803 Current time

    804 Meter No. 805 SGC

    806 Relay Off Reason 807 Meter status

    808 Impulse Constant 809 Power off times

    810 Over credit limit 811 Emergency credit

    812 Cancel alarm 813 Last day kWh

    814 Current month kWh 815 Latest credit date

    816 Latest credit time 817 Latest credit amount

    818 Latest Credit TOKEN 819 Latest Credit return code

    821 Last 1 month kWh 822 Last 2 month kWh

    823 Last 3 month kWh 824 Last 4 month kWh

    825 Last 5 month kWh

  • 8/10/2019 User ManualHXE34 Indonesia

    20/26

    HXE34 three phase keypad meter

    20

    831 Last 1 month credit kWh 832 Last 2 month credit kWh

    833 Last 3 month credit kWh 834 Last 4 month credit kWh

    835 Last 5 month credit kWh

    851 Total credit kWh 852 Last two credit TOKEN

    853 Last three credit TOKEN 854 Last four credit TOKEN

    855 Last five credit TOKEN

    NOTE:

    Relay Off Reasons

    1: No balance and have not used the overdraft

    2: No balance and have used the overdraft

    3: Over load

    4: Power outage under the STS testing mode

    5: Opening the meter cover

    6: Opening the terminal cover

    Event state:

    15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

    0 digit: history meter cover open log

    1st digit: history terminal cover open log

    2nddigit: history A phase overvoltage

    3thdigit: history B phase overvoltage

    4th

    digit: history C phase overvoltage

    5thdigit: history A phase under-voltage

    6thdigit: history B phase under-voltage

    7thdigit: history C phase under-voltage

    8th digit: history overload

    9th digit: history A phase reverse

    10thdigit: history B phase reverse

    11th digit: history C phase reverse

  • 8/10/2019 User ManualHXE34 Indonesia

    21/26

    HXE34 three phase keypad meter

    21

    12thdigit: history three phase unbalance

    Meter ID

    Base on the STS standard, meter number is 11-digit number, the first two 2-digit

    is the exclusive ID of company, the last 1-digit is verify key, the middle of 8-digit

    is the meter number that displayed by LCD

    There is 00 shown on LCD to indicate the short code is 800, and the total

    electricity consumption is 100.00kWh.

    The short code 850 is inexistent:

    The last credit information is inexistent:

  • 8/10/2019 User ManualHXE34 Indonesia

    22/26

    HXE34 three phase keypad meter

    22

    Canceled alarm under the voice-alarm state

    Canceled alarm under the no voice-alarm state

    5.7 Relay Control

    The relay will disconnect by this reasons: lacking balance, relay disconnect under

    the STS testing mode, open the cover of meter and terminal

    If the disconnection is based on these reasons, relay will connect automatically

    when event returned; if the disconnection is based on lacking balance, relay will

    connect automatically until credit; if the disconnection is based on opening the

  • 8/10/2019 User ManualHXE34 Indonesia

    23/26

    HXE34 three phase keypad meter

    23

    cover of meter and terminal, relay still disconnect even the cover closed but user

    input the TOKEN code of cleanup

    The balance would account toward negative under the emergency overdraft mode

    or caused by performance failure of relay when balance is lack.

    5.8 Over Loading Management

    The load shall be disconnected when the load power threshold has been exceeded.

    1. Current power is greater than maximum rated power, if continuous time is

    30seconds, the relay opening.

    2. After 30 seconds, connect the relay, and then implement the overload

    detection.

    3. If is still overload, turn to the 1 cycle; if do not occur overload in continuous 30

    minutes, clear the overload event record data.

    4. If detect the overload 5 times, meter will record the overload event,.

    5. After 30 minutes, connect relay retry overload disposal and clear the overload

    event record data.

    Note:If power off occurs during the disposal process, overload disposal will start

    from its original status; if relay operating fails, it will continue the process

    according to over loading disposal t procedure.

    5.9 Event Record

    There are 4 types of events.

    The 1st event: meter reset. The meter will record the total reset times and the last

    3 occurred time.

    The 2nd events: power off, meter cover open, meter terminal open, relay off,

  • 8/10/2019 User ManualHXE34 Indonesia

    24/26

    HXE34 three phase keypad meter

    24

    A,B,C 3 phase unbalance, A,B,C 3 phase over voltage, A,B,C 3 three phase low

    voltage, A,B,C 3 phase reverse, 3 phase unbalance. Every event is recorded the

    total occurred times and accumulated time and the last 3 starting time and end

    time.

    Meter cover open and meter terminal open condition: the event is detected

    continuous 10s will act as event starting time and 5s will act as event end time.

    The phase A,B,C (over voltage, low voltage, reverse, unbalance) events has to be

    detected continuous 3 min.

    The 3rd event is programing meter.The meter will record the total occurred time

    and the last 3 programmable ID and occurring time.

    The 4th event is credit. The meter will record the total occurred time and the last

    10 credit time, value, and token.

    5.10 Event indicators

    S1 : Power-on indication

    S2 : Meter cover open indication

    S3 : Terminal cover open indication

    S4 : Overload indication

    S6 : Meter under 3 phase unbalanced status

    S8 : Under the key set state

    5.11 Up-limit Credit

    There is a register can be setup that is upper limit register of the credit. If the

    meters credit is more than upper limit after credit, the credit is unsuccessfully.

  • 8/10/2019 User ManualHXE34 Indonesia

    25/26

    HXE34 three phase keypad meter

    25

    5.12 Back-up Battery

    The meter will use the back-up battery when power outage, LCD will display

    when battery is low voltage.

    5.13 Fixed Expense

    Fixed expense have no relationship with energy consumption, the fixed expense

    is reduced at 06:00 every day.

    6 Meter storageThe meters transportation and storage must be the original package. The meter is

    better to indoor installation than outdoor installation. It must be installed in the

    meter box if outdoor installation. The meter belongs static instrument, so please

    do not open the meter cover.

  • 8/10/2019 User ManualHXE34 Indonesia

    26/26

    HXE34 three phase keypad meter

    26

    Hexing Electrical Co., Ltd.

    10thFloor, Zhong Tian Mansion, No. 173 Yugu Road, Hangzhou, China

    Tel: (86) 571 28020767, 28020769 Fax: (86) 571 8797 6199

    www.hxgroup.cn

    http://www.hxgroup.cn/http://www.hxgroup.cn/