24
xComfort Room Controller Touch User Manual 0v17_EN xComfort Room Controller Touch User Manual

User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN

xComfort Room Controller Touch

User Manual

Page 2: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN ii | P a g e

• For other languages and information about xComfort, visit

www.eaton.eu/xcomfort or www.xcomfort.com or use the QR-code.

• Für weitere Sprachen und Informationen zum xComfort System

besuchen Sie ww.eaton.eu/xcomfort oder www.xcomfort.de oder

verwenden Sie den QR-code

• Besok www.xcomfort.no eller www.eato.eu/xcomfort for andre språk

og mer informasjon om xComfort eller bruk QR-koden.

• Pro další jazyky informace o xComfort návštěvy

www.eaton.eu/xcomfort nebo www.xcomfort.cz nebo použijte QR

kód.

• Voor andere talen en meer informatie over xComfort ga naar

www.eaton.nl/xcomfort of www.xcomfort.nl of maak gebruik van de

QR-code

Page 3: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN iii | P a g e

Table of Contents 1. Introduction ......................................................................................................................................... 1

1.1 Safety instructions .......................................................................................................................... 1

1.2 Intended use .................................................................................................................................. 1

1.3 Instructions for disposal ................................................................................................................. 1

1.4 About this document ...................................................................................................................... 1

2 The Room Controller Touch .................................................................................................................. 2

2.1 Operation ....................................................................................................................................... 2

2.2 Cleaning mode ............................................................................................................................... 3

2.3 Replacing the batteries ................................................................................................................... 3

2.4 Operation mode ............................................................................................................................. 4

2.4.1 Basic operations ...................................................................................................................... 4

2.4.2 Enhanced operations ............................................................................................................... 4

2.4.3 Settings edit operations ........................................................................................................... 4

2.5 Basic Operating Instructions ........................................................................................................... 5

2.5.1 Show Current Room Temperature ........................................................................................... 5

2.5.2 Show Current/Active Set-Point Temperature ........................................................................... 5

2.5.3 Temporarily adjust the current set-point temperature............................................................. 6

2.5.4 Switch active set-point temperature (operation mode) ........................................................... 6

2.5.5 Show Room Humidity .............................................................................................................. 7

2.5.6 (Optional) Show outdoor temperature. ................................................................................... 7

2.5.7 (Optional) Show Time and Day of Week ................................................................................... 8

2.5.8 (Optional) Touch-button(s) ...................................................................................................... 8

2.6 Enhanced Operating Instructions ................................................................................................... 9

2.6.1 (Optional) Activate/Deactivate Week Program ........................................................................ 9

2.6.2 (Optional) Selecting Heating and/or Cooling mode ................................................................ 10

2.7 Edit Operating Instructions ........................................................................................................... 11

2.7.1 Change Pre-Defined Set-Point Temperature .......................................................................... 11

2.7.2 (Optional) Edit Week Program Timer ..................................................................................... 13

2.7.3 (Optional) Edit humidity Set-point ......................................................................................... 15

2.7.4 (Optional) Edit/Set Current Time and Date ............................................................................ 16

2.7.5 (Optional) Edit/Set Monthly clock correction factor ............................................................... 18

Page 4: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN iv | P a g e

Page 5: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 1 | P a g e

1. Introduction

1.1 Safety instructions This document contains important warnings and safety instructions which must be observed and

followed by the users. Failure to follow these warnings and safety instructions will put the fault-free

operation of the Room Controller Touch at risk.

1.2 Intended use The Room Controller Touch has been designed solely for residential use in private homes and small

offices. It is not suitable for industrial use.

The Room Controller Touch is designed to facilitate the climate control in a room and provide the user

access to this through an intuitive LCD Touch screen menu.

The Room controller can operate in two application modes:

• Control mode; in which the Room Controller Touch controls the regulation of the climate in a room

• Sensor mode; in which the Room Controller Touch registers the room climate conditions and the

user settings and sends them to an intelligent device, e.g. xComfort Smart Home Controller (SHC),

which actually controls the climate in the room.

Since the transmission of radio signals is based on a non-exclusive communication channel,

interference to the transmission are possible. Because of this, the Room Controller Touch

must not be used to control components with safety-related functions, such as

overheating protection, emergency stop or emergency call.

The use of the unit for any purpose other than described in this document or the failure to observe the

warnings and safety instructions it contains will immediately invalidate any claims in respect to the

warranty and/or liability.

1.3 Instructions for disposal Do not dispose of this device with regular domestic waste.

Electronic equipment must be disposed of at local collection points for waste electronic

equipment and in compliance with the local regulations governing waste electrical and electronic

equipment.

1.4 About this document These operating instructions are intended for end users and describe the operation and menu structure

of the Room Controller Touch.

Certain functions and their availability depend on the configuration of the Room Controller Touch during

the installation. These functions are marked with (Optional).

Please contact a suitable qualified electrical engineer for all assembly, installation and

basic configuration requirements or if you need to remove or dispose of the device.

Faulty installation or configuration can otherwise cause damage to property and persons.

Page 6: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 2 | P a g e

2 The Room Controller Touch

2.1 Operation The Room Controller Touch is equipped with a Display with Backlight and Touch function. The display is

used to display the information through which, by touching the display, the Room Controller Touch can

be operated.

Note: The display is designed to respond to on-screen pressing only. Compared to the commonly

used touch displays for smartphones and tablets it may be the case that touching the

display a little more firmly is necessary.

In the Idle-state the display shows the temperature and status with the backlight switched off. On

touching the display it enters the Active-state. In this state, the backlight is switched on, and when

connected to the xComfort SHC, the information is refreshed to get the latest status.

Note: To maximize the battery life, a delay between the information on the display in the idle-

state and the actual status in the xComfort SHC is possible. The maximum possible delay

can be reduced by the installer, but this will lead to a reduction in the battery life. In other

configurations the display always contains the latest information.

Pre-defined temperature set-points

Frost protection

Night / Standby

Economy

Day / Comfort

Request status

Heating request

Cooling request

Ventilation request

Shown information selection

Temperature

Humidity

Clock

Outdoor temperature

Various

Units of the shown information

Setting

Touch-button

Floor temperature regulation active

Low battery indication

Week program timer

Week program timer activity status

Day of Week

Program timer switch time-point

Page 7: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 3 | P a g e

2.2 Cleaning mode To prevent unwanted changes during the cleaning of the Room Controller Touch, the display can be put

into the cleaning mode.

The Room Controller Touch must only cleaned with glass cleaner or window cleaner, and

never with abrasive products

During the cleaning mode, the Room Controller Touch will ignore any touching on the display. The

display shows the remaining time in seconds until the Room Controller Touch switches back to normal

operation mode.

2.3 Replacing the batteries The Room Controller Touch operates with 2x LR03 (AAA) batteries which are located in the rear section

of the Room Controller.

Replace the batteries when the low battery indicator is shown on the display.

Note: Optionally, the Room Controller can also be used with an external mains power adapter. In

this case batteries are not required. Contact your installer for more information.

Do NOT press the center of the display to mount!! For the correct mounting, with two

hands, simply press the outer frame of the Room Controller Touch.

Used batteries should not be disposed of with regular domestic waste. They should be

taken to a battery disposal point.

Never recharge standard batteries!! This entails a risk of explosion.

Do not throw the batteries into fires

Do not short-circuit batteries

>10 Sec.

Page 8: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 4 | P a g e

2.4 Operation mode The operation functions of the Room Controller Touch are grouped into the following:

• Frequently used operation functions, Basic operation functions.

• Occasionally used operation functions, Enhanced operation functions

• Changes to the settings, Edit operation functions

Note: To start operating the Room Controller Touch, touching the screen once is necessary to

activate the display.

To maximize the battery life, the Room Controller Touch display will enter the Idle-state. In this state,

the display shows the temperature and status with the backlight switched off. On touching the display

again it enters the Active-state. In this state, the backlight is switched on, and when connected to the

xComfort SHC, the information is refreshed to get the latest status.

2.4.1 Basic operations

• Show the current temperature

• Temporary adjust the current set-point temperature

• Show the current set-point temperature

• Select (another) per-defined set-point temperature (operation mode)

• Show the current humidity

• (Optional) Show outdoor temperature

• (Optional) Show time and Day of Week

• (Optional) Touch-button(s)

2.4.2 Enhanced operations

• Select regulation mode; Heating, Cooling, (Optional) Heating&Cooling or OFF mode

• (Optional) Switch Week Program Timer ON or OFF

2.4.3 Settings edit operations

• Edit pre-defined Set-point temperatures

• (Optional) Edit Week Program

• (Optional) Edit Humidity Set-point

• (Optional) Edit Time and Date

• (Optional) Edit clock correction factor

Page 9: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 5 | P a g e

2.5 Basic Operating Instructions

2.5.1 Show Current Room Temperature

The default screen on the display shows the current temperature. After a timeout, the Room Controller

will always return to this default screen. It is also possible to manually select the default ‘current

temperature screen’.

2.5.2 Show Current/Active Set-Point Temperature

The set-point temperature which currently is used for the regulation of the temperature in the room can

be shown.

Note: The active set-point temperature is the sum total of the active pre-defined operation mode

set-point temperature and the temporary adjustment (increase or decrease) that is made.

Initial

Step 1

(Optional)

Select the Heating or

Cooling set-point

Idle

Timeout

Page 10: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 6 | P a g e

2.5.3 Temporarily adjust the current set-point temperature

It is possible to temporarily increase or decrease the current set-point temperature. The temporary

increase or decrease in the set-point temperature will be reset to zero when the operation mode (pre-

defined set-point temperature) is changed, either manually or via the Week Program Timer.

Note: To change the set-point temperature permanently, see the following section: ‘Edit

Operating Instructions - Change Pre-Defined Temperature Set-point’.

Initial

Step 1

Optional Selection of

Heating or Cooling set-

point

Step 2

Idle

Timeout

2.5.4 Switch active set-point temperature (operation mode)

The Room Controller Touch supports four different pre-defined and reprogrammable set-point

temperatures (operation modes) for an easy change in the desired (set-point) temperature during the

day. It is possible to manually switch between these pre-defined set-point temperatures.

The pre-defined set-points can also be used in the Week Program (when enabled) to switch

automatically between the different set-point temperatures on a timed basis,

Note: The Week Program will be switched OFF when the active set-point temperature (operation

mode) is changed manually.

Page 11: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 7 | P a g e

Initial

Step 1

Step 2

Idle

Timeout

2.5.5 Show Room Humidity

The Room Controller Touch also measures the humidity in the room, and the humidity can be displayed

by selecting the display humidity screen.

2.5.6 (Optional) Show outdoor temperature.

Sensor mode

This option is available when the Room Controller is connected to an intelligent device which provides

the outdoor temperature.

Control mode

The option is available in control mode if, during installation, the external temperature sensor input is

configured for use as an outdoor temperature sensor.

Page 12: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 8 | P a g e

2.5.7 (Optional) Show Time and Day of Week

Optionally, the current time can be displayed. The option is available in both the sensor mode and the

control mode if the Week Program Timer is enabled during the installation.

2.5.8 (Optional) Touch-button(s)

The Touch-buttons of the Room Controller Touch can be used as push buttons to control the lights,

shutters/blinds in the room, for example, or to trigger Scenes in the xComfort SHC.

Note: To get the Touch-buttons, an actuator or intelligent device must be connected to the

Touch-button of the Room Controller during the installation. Contact your installer for

more information.

The Room Controller Touch has up to two Touch-buttons . Their behavior depends on the

configuration during the installation:

• 2x Single Pushbuttons: Each Touch-button is connected individually to an actuator(s) or to an

intelligent device (e.g. the xComfort SHC). The Touch-button acts as single pole pushbutton.

The Touch-button supports short pressing (e.g. switch on/off) and long pressing (e.g. dimming

up/down).

• 2x Single Rocker with arrow keys: Each Touch-button is individually connected to an actuator(s)

or to an intelligent device (e.g. xComfort SHC).

When the Touch-button is pressed it will start flashing, and the arrow keys are shown, which can

be used ‘up ‘ or ‘down’. In this respect on the ‘up’ key, apply a short press to switch on and a

long press to dim up. Press briefly on the ‘down’ key to switch off or to dim down.

• 1 Single Rocker: Both Touch-buttons are connected to the same actuator(s). The pair of Touch-

buttons behave as one 2 pole pushbutton. The Touch-button on the left is the ON/UP

(short/long press) part and on the right the OFF/DOWN part.

Page 13: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 9 | P a g e

2.6 Enhanced Operating Instructions

2.6.1 (Optional) Activate/Deactivate Week Program

The Week Program can be optionally deactivated (OFF) or activated (ON). When it is OFF, it is only

possible to manually switch between the pre-defined set-point temperatures (operation mode), and

when it is ON, the operation mode is based on the programmed week program.

Control mode

If the Week Program Timer function is enabled during the installation (MRF), the option to activate or

deactivate the Week Program is available in the control mode only.

Sensor mode

In the Sensor mode the option is available when connected with the xComfort SHC (e.g. Room Manager),

otherwise the Week Program is not available.

Note: If the Week Program is activated (ON), then the operation mode will switch to the correct

operation mode according to the week program for the current time.

Optional

Step 1

Step 2

Step 3 Timeout

Deactivated (OFF) Activated (ON)

Page 14: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 10 | P a g e

2.6.2 (Optional) Selecting Heating and/or Cooling mode

It is possible to select which temperature regulation mode should be active manually.

(OFF) No icons displayed. No heating or cooling, e.g. regulation switch off.

Heating mode. Regulation based on heating set-point(s) temperature only.

Cooling mode. Regulation based on cooling set-point(s) temperature only.

Heating&Cooling mode. Regulation based on both heating and cooling set-points

temperature.

Sensor Mode

If the Room Controller is connected to an xComfort SHC, it is possible to change manually between

‘heating’, ‘cooling’ and ‘OFF’. In this case, the ‘Heating&Cooling’ mode is not available. When connected

to a Room Manager the temperature regulation mode cannot be changed.

Control Mode

* The available regulation modes depend on the configuration. If a heating or a cooling actuator is

connected only, then it is only possible to switch between ‘heating and OFF’ / ‘cooling and OFF’

manually. If both actuators are connected, then all modes are available.

Optional

Step 1

(Show mode)

Current active mode is shown

Step 2

(Select mode)

Control Mode*

(OFF)

Sensor Mode

(OFF)

Optional

Timeout

Page 15: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 11 | P a g e

2.7 Edit Operating Instructions

2.7.1 Change Pre-Defined Set-Point Temperature

The Room Controller Touch supports up to 2 x 4 (4 for heating and 4 for cooling) different pre-defined

set-point temperatures (operation modes) which can be manually (re-)programmed via the screen.

Frost protection mode. Factory default values 10°C/32°C (or -5K with Room Manager)

Standby or Night mode. Factory default values 18°C/28°C (or -0,5K with Room Manager)

Economy mode. Factory default values 19°C/26°C (or -1K with Room Manager)

Comfort or Day mode. Factory default value 21°C/24°C (or 0K with Room Manager)

Sensor mode

When connected to the xComfort SHC, the values of the pre-defined temperature are the same as the

set-point temperatures in the SHC. Making a manual change on the Room Controller Touch will also

change the set-point in the SHC (and v.v.).

When connected to a Room Manager, the predefined temperatures are used as offset in the Room

Manager for the Room Manager’s current set-point temperature.

Control mode

The initial values used in controller mode are programmed during the installation (MRF). The set-point

values are used by the Room Controller Touch for the climate control.

Note: If the ‘Heating&Cooling’ mode is active, the Room Controller will maintain a minimum

temperature difference between the heating set-point and cooling set-point temperature

(dead zone) to prevent the continuous switching between heating and cooling. This dead

zone value can be configured during installation. The factory default is 3K.

Optional

Step 1

Page 16: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 12 | P a g e

Enter Edit mode

Step 2

(Select Edit)

Edit icon flashing

Enter Edit Set-point temperature

Re

pe

at

th

is f

or

oth

er

set-

po

ints

wh

en

re

qu

ire

d Optional

Select the Set-point

Optional

Select the Heating or

Cooling Set-point

Step 3

(Change)

Changed value is flashing

Leave Edit mode

Step 4

Timeout or

Idle Timeout

Page 17: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 13 | P a g e

2.7.2 (Optional) Edit Week Program Timer

Sensor mode

When connected to an intelligent device, the climate control is carried out by the intelligent device and

based on the Week Program programmed in the intelligent device. Changes to the Week Program should

therefore be made in the intelligent device.

Control mode

In the control mode, the Week Program Timer is available if it is enabled during the installation (MRF).

The Room Controller Touch supports up to 6 manually (re-)programmable points for each Day of Week

at which time the Room Controller Touch should switch the active set-point temperature (operation

mode), and to which of pre-defined set-point temperatures (operation mode) it should switch.

Step 1

Step 2

Enter Edit mode

Step 3

(Select Edit)

Edit icon flashing

Step 4

(Enter Program edit)

The Day of week and Trigger point

are flashing

Enter Edit Program

Re

pe

at

this

Select Day of Week

Selected is flashing:

- The Day of the Week or

- Midweek: (Mo +…+ Fr) or

- Weekend: ( Sa + Su)

Page 18: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 14 | P a g e

Select Switch point

Selected Switch point is flashing

To change the pre-defined set-point

Change Pre defined

Set-point

Selected Set-point has an underscore

To Change the Time minutes

Change Time

minutes

Step 1

(Select)

Minutes are flashing

Step 2 (Change)

To Change the Time hours

Change Time Hour

Step 1 (Select)

Hours are flashing

Step 2 (Change)

Page 19: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 15 | P a g e

Leave Edit mode

Step 6

(Leave Edit mode)

Timeout or

Idle

Timeout

2.7.3 (Optional) Edit humidity Set-point

Sensor mode

The Humidity set-point is not available if the Room Controller is connected to an intelligent device, e.g.

SHC or Room Manager.

Control mode

This option is available in control mode if a humidity actuator is connected to the Room Controller Touch

during the installation. The Room Controller Touch will send an OFF command to the actuator if the

humidity is above the set-point value, and it will send an ON command if the actual humidity is below

the set-point value. The set-point value can be changed manually.

Initial select Humidity

Edit mode

Enter

Change

Page 20: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 16 | P a g e

Leave Timeout or

2.7.4 (Optional) Edit/Set Current Time and Date

Sensor Mode

The option to set the Time and Date manually with the Room Controller is not available if the Room

Controller is connected to an xComfort SHC. In this case, the time and date are synchronized with the

xComfort SHC date and time.

Control Mode

The Time (Hours, Minutes) and Date (Day of Week, Day of Month, Month and Year) can be set manually

if the Week Program is enabled during installation.

Attention:

The time and date are used for the execution of the Week Program. The Time and Date

need to be set correctly for the correct operation of the Week Program

Initial select Clock

Enter Edit Mode

Page 21: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 17 | P a g e

Select Item and change

Re

pe

at

this

ste

p f

or

ea

ch

ite

ms

th

at

ne

ed

s to

be

ch

an

ge

d

Select

Number (1-6) is flashing

Hours

Minutes

Day of Week

Day of Month

Month

Year

Change

Use the arrow-keys to

change

When changed the changed numbers

starts flashing

Leave Edit Mode Timeout or

Page 22: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 18 | P a g e

2.7.5 (Optional) Edit/Set Monthly clock correction factor

Any inaccuracy to the Room Controller Touch internal clock can be corrected by configuring the number

of seconds that the clock needs to be corrected by each month (-99 to +99 seconds).

Note: The accuracy of each clock may vary slightly, which can make the clock go out of sync with

the current time. This results in the Week Program switching to the desired set-point

temperature too early or too late.

The option is only available if the clock function is enabled during the installation and if the Room

Controller does not receive the time and date from another device.

Initial select clock

Enter Edit Press Edit > 5 Sec

Change

Leave Edit

Page 23: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 19 | P a g e

Page 24: User Manual xComfort Room Controller Touch 0v18 EN · xComfort Room Controller Touch User Manual 0v 17_EN 6 | Page 2.5.3 Temporarily adjust the current set-point temperature It is

xComfort Room Controller Touch User Manual 0v17_EN 20 | P a g e

© Eaton Industries (Austria)

Eugenia 1

3943 Schrems

Austria

www.xcomfort.com

www.eaton.eu/xcomfort